Rayzon Poly Crystaline Solar Panel
Rayzon Poly Crystaline Solar Panel
Rayzon Poly Crystaline Solar Panel
Solar Modules
POLY 250W - 335W
CB Scheme
Pre and Post EL Checking IEC 61215 IEC 61730-1 / 2 IEC 61853-1 ISO 9000
Ip68 Junction Box IEC 62716 IEC 61701 IEC 62804 IS 14286
www.rayzonsolar.com
TECHNICAL DATA
PERFORMANCE UNDER STANDARD TEST CONDITIONS (STC) (irradiance of 1000 W/m², spectrum AM 1.5 and cell temperature of 25°C.)
Nominal Maximum Power (Pmax) 250W 260W 265W 270W 300W 310W 315W 320W 325W 330W 335W
Optimum Operating Voltage (Vmp) 31.27 31.52 31.99 32.10 37.51 37.81 37.94 38.40 38.60 38.85 39.00
Optimum Operating Current (Imp) 8.00 8.25 8.29 8.43 8.00 8.20 8.31 8.35 8.43 8.50 8.60
Open Circuit Voltage (Voc) 37.50 37.74 37.86 38.7 45.00 45.29 45.36 45.50 45.64 45.79 46.15
Short Ciruit Current (Isc) 8.56 8.83 8.95 8.96 8.56 8.77 8.88 8.95 8.97 9.04 9.09
Module Eff(%) 15.4 16.0 16.3 16.6 15.5 16.0 16.2 16.5 16.7 17.0 17.26
PERFORMANCE UNDER NOCT (NOCT irradiances of 800 W/m², ambient temperature of 20°C, Wind speed 1m/sec)
Nominal Maximum Power (Pmax) 181.48 188.73 192.36 195.99 217.77 225.03 228.66 232.29 235.92 239.55 243.18
Optimum Operating Voltage (Vmp) 28.53 28.76 29.18 29.94 34.22 34.49 34.61 35.03 35.21 35.44 35.58
Optimum Operating Current (Imp) 6.36 6.56 6.59 6.70 6.36 6.52 6.61 6.64 6.70 6.76 6.84
Open Circuit Voltage (Voc) 34.61 34.83 34.94 35.72 41.53 41.80 41.86 41.99 42.12 42.26 42.59
Short Ciruit Current (Isc) 6.87 7.08 7.18 7.19 6.87 7.03 7.12 7.18 7.19 7.25 7.29
Mechanical Specifications
Dimensions (L x W x T in mm) 1640 x 990 x 40 1960 x 990 x 40
Weight(kg) 19.2 21.48
No Of Cell 60 [10x6] 72 [12x6]
Aluminum Frame [40HS] Silver Anodized Aluminum Alloy Silver Anodized Aluminum Alloy
Front Cover (Tempered Glass) 3.2mm 3.2mm
Encapsulate (EVA) Ethylene Vinyl Acetate Sheet (EVA) Ethylene Vinyl Acetate Sheet
Back Sheet Composite Film Composite Film
Junction Box with 3-Bypass diode 4 terminal Junction Box (IP68) 4 terminal Junction Box (IP68)
Application Class Rating Class A Class A
Safety Class Rating Class II Class II
Mechanical Load Test (as per IEC & UL) 5400 Pa-Front; 2400 Pa-Back 5400 Pa-Front; 2400 Pa-Back
Mounting Holes Pitch (Y)-mm [A] 820 [A] 1360, [B] 980
Mounting Holes Pitch (X)-mm 952 952
8
Current (A)
6
Incident Irrad. = 1000 W/m2
Cable Length 1200mm
0
0 10 20 30 40 50
Voltage (V)
1960 / 1640mm
Grounding Hole 10
Cell Temp. = 25°C
(ø4 mm, 2 Nos) Incident Irrad. = 1000 W/m
2
8
2
Incident Irrad. = 800 W/m
Current (A)
6 2
Incident Irrad. = 600 W/m
2
2 Incident Irrad. = 200 W/m
0
0 10 20 30 40 50
Drain Hole Voltage (V)
(ø3 mm, 8 Nos)
*All dimensions are in mm with +/-1% tolerance.
Cau on: Please read safety and installa on instruc ons before using the product. *Warranty: Linear power warranty for 27 years up to 2.5% for 1st year degrada on
and 0.67% from year 2 to year 27. Please read Rayzon warranty documents thoroughly. Disclaimer: specifications included in the datasheet are subject to change without
prior notice owing to conditions innovation on the product Development and R&D Activities. RAYZON GREEN ENERGIES reserves the right to make any adjustment to the
information described here, Dataset contained in this specification do not form a representative of a single module data. @T&C Apply.
www.rayzonsolar.com