100% found this document useful (1 vote)
821 views4 pages

Model: 10EOZD 9efozd: 60 HZ 50 HZ 1-Phase Diesel

This document provides specifications for 1-phase diesel marine generator sets including engine features, generator features, weights and dimensions, ratings, and operation requirements. Key details include: - Models: 10EOZD (60Hz), 9EFOZD (50Hz) - EPA Tier 4 emissions compliant (60Hz model) - Closed cooling system, heat exchanger, electric fuel pump - Voltage regulation of ±1.5%, radio suppression - Advanced digital control panel with monitoring and configuration - Marine continuous ratings per industry standards - Air and fuel consumption rates provided at varying loads

Uploaded by

Teszt Sdj
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
100% found this document useful (1 vote)
821 views4 pages

Model: 10EOZD 9efozd: 60 HZ 50 HZ 1-Phase Diesel

This document provides specifications for 1-phase diesel marine generator sets including engine features, generator features, weights and dimensions, ratings, and operation requirements. Key details include: - Models: 10EOZD (60Hz), 9EFOZD (50Hz) - EPA Tier 4 emissions compliant (60Hz model) - Closed cooling system, heat exchanger, electric fuel pump - Voltage regulation of ±1.5%, radio suppression - Advanced digital control panel with monitoring and configuration - Marine continuous ratings per industry standards - Air and fuel consumption rates provided at varying loads

Uploaded by

Teszt Sdj
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 4

Model: 10EOZD 60 Hz

9EFOZD 50 Hz

1-Phase Diesel

Marine Generator Set


Engine Features
D Diesel fueled
D Three cylinder
D Four cycle
D Certified by the Environmental Protection Agency
(EPA) to conform to Tier 4 emissions regulations
(60 Hz model only)
D Closed cooling system
D Heat exchanger
D Electric fuel lift pump
D Lifting eyes

Generator Features
D Remote start 12-pin connector
D Class H insulation
D Multivoltage adjustability
D Voltage regulation of ±1.5%
Generator Weights and Dimensions D Radio suppression

Without With ADC 2100 Advanced Digital Control


Sound Shield Sound Shield
Features
Weight, kg (lb.) D Designed for today’s most sophisticated electronics
Wet 263 (580) 310 (684) D Easy to read alpha-numeric display
Dry 259 (570) 306 (674) D Compact, integrally mounted control
Length, mm (in.) D Potted boards/sealed connectors for maximum
12 volt 857 (33.73) 934 (36.75) corrosion protection
24 volt 870 (34.24) D SAE J-1939 CANbus output
D Remote monitoring of up to 13 fault conditions
Width, mm (in.) D Membrane keypad for configuration and
12 volt 520 (20.47) 578 (22.75) adjustment
24 volt 532 (20.95) D Programmed crank cycle
Height, mm (in.) 618 (24.31) 664 (26.15)
Optional Accessories
Generator Ratings D Sound shield
D Remote digital gauge
25_C (77_F) 25_C (77_F) D Siphon break
Model Series Voltage Hz Amps kW/kVA Ph D Circuit breakers
120 60 83.3 10/10 1
10EOZD
120/240 60 83.3/41.7 10/10 1
115/230 50 78/39 9/9 1
9EFOZD 230 50 39 9/9 1
240 50 37.5 9/9 1
RATINGS: Marine continuous ratings per ISO 3046, ISO 8528-1, and Kohler ISO rating
guideline 2.14. Obtain technical information bulletin (TIB-101) on ratings guidelines for complete
ratings definitions.
Availability is subject to change without notice. Kohler Co. reserves the right to change the design or
specifications without notice and without any obligation or liability whatsoever. Contact your local
Kohler generator distributor for availability.

10% Overload Capacity One Hour in Twelve Hours

G2-134 (10EOZD) 11/10a


Application Data
Engine Operation Requirements
Engine Specifications 60 Hz 50 Hz Air Requirements 60 Hz 50 Hz
Type 4 cycle Engine combustion air requirements,
Cylinder, quantity 3 L/min. (cfm) 1080 (38.1) 900 (31.8)
Engine/generator cooling requirements,
Displacement, L (cu. in.) 1.33 (81.14)
L/min. (cfm) 4814 (170) 3964 (140)
Bore and stroke, mm (in.) 82 x 84 (3.23 x 3.30) Max. air intake restriction,
Compression ratio 19.2:1 kPa (mm H2O) 6.23 (635)
Combustion system Direct injection Exhaust flow, m3/min. (cfm) 2.7 (98) 2.2 (78)

Rated rpm 1800 1500 Exhaust temp., °C (°F) 550 (1022) 510 (950)
Max. allowed exhaust back pressure,
Max. power at rated rpm, HP 18.4 15.1 kPa (mm H2O) 15.30 (1560)
Cylinder block material Cast iron
Fuel Consumption 60 Hz 50 Hz
Cylinder head material Cast iron
Diesel, Lph (gph) at % load
Piston rings: quantity, type 2 compression/1 oil 100% 4.0 (1.05) 2.5 (0.67)
Crankshaft material Forged steel 75% 2.7 (0.72) 1.8 (0.47)
Connecting rod material Forged carbon steel 50% 2.0 (0.53) 1.7 (0.45)
Governor, type Centrifugal, mechanical 25% 1.3 (0.35) 1.1 (0.30)
Frequency regulation, mechanical Note: The fuel consumption of the 60 Hz model is based on 10EOZD
governor and the fuel consumption of the 50 Hz model is based on 9EFOZD.
No load to full load (droop) . . . . . . ±5%
Steady state . . . . . . . . . . . . . . . . . . . ±0.8%
Engine Features
Engine Electrical D One-side serviceability of fuel system, lubrication system, seawater
pump, and air cleaner
Engine Electrical System 60 Hz 50 Hz
D Low oil pressure shutdown
Battery, voltage 12 volt (standard)
24 volt (optional) D High engine temperature shutdown

Battery, charging 40-amp alternator D Loss of coolant shutdown


D Focused vibromounts
Battery, minimum recommendation 500 CCA, 100 amp hr.
D Belt guard
Starter motor 1.8 kW Bendix,
gear-reduction D Disposable oil filter
automotive type D Oil drain valve and hose
D Full flow cooling system (thermostat bypass)
Cooling
D Air intake heater circuit for cold starting (optional)
Cooling System 60 Hz 50 Hz
Capacity, L (qt.), approx. 2.46 (2.6) Generator Features
Heat exchanger type 2.5 in. dia. x 3 pass D Brushless, rotating field design permits power to be obtained from
cupronickel stationary leads.
D Rotor and stator are vacuum impregnated and coated with high-bond
Seawater pump type Belt-driven,
epoxy varnish. Varnish helps prevent corrosion in high-humidity
10-blade impeller
areas.
Heat rejected to cooling water at rated D Rotors are dynamically balanced to minimize vibration.
kW, wet exhaust, kW (Btu/min.) 10.0 (574) 8.3 (472)
D Copper windings ensure minimal heat buildup. Insulation meets
Engine water pump flow, Lpm (gpm) 32.4 (8.6) 27.0 (7.1) NEMA standards for class H insulation.
Seawater pump flow, Lpm (gpm) 22.7 (6.0) 18.9 (5.0) D Direct connected to the engine, the generator has sealed precision
ball bearings with a precision-machined steel sleeve in the end
Fuel bracket to prevent shaft misalignment and extend bearing life.

Fuel System 60 Hz 50 Hz D Mounted on a drip-proof tray.


Fuel shutoff solenoid Electric D Equipped with a four-lead reconnectable stator.

Fuel pump Electric, rotary vane


Fuel pump priming Electric
Maximum recommended fuel lift, m (ft.) 1.2 (4.0)

Lubrication
Lubricating System 60 Hz 50 Hz
Oil pan capacity with filter, L (qt.) 3.6 (3.8)
Oil pump type Pressure, trochoid pump

G2-134 (10EOZD) 11/10a


Application Data
ADC 2100 Control Features Accessories
Sound Shield
Provides for highly effective silencing, ease of access for
engine/generator servicing, low maintenance, excellent
durability, and safety. The sound shield’s customer
connection panel includes connections for the following:
d Battery (positive and negative)
d Equipment ground
d Fuel inlet and return
d Seawater inlet
d Water-cooled exhaust outlet
d Oil drain
d Customer load lead access
D LED display: d Customer interface
d Runtime hours
Siphon Break
d Crank cycle status
d Diagnostics/fault codes/data Mandatory kit on generators installed below the waterline.
Prevents the siphoning of flotation water into the engine.
D Keypad
d Secure access, password protected Line Circuit Breakers
d Voltage, gain, and speed adjustment Protect the generator from extreme overload.
d Controller configuration (system voltage, phase, and
frequency settings, battery voltage, and generator set Preheat Kit
model)
Provides improved starting in cold climates.
D Master control switch: run/off-reset/auto (engine start)
D Remote two-wire start/stop capability Ship-to-Shore Switch
D Potted electronics and sealed connections Allows immediate switching to Kohlerr generator set
D Voltage regulation ±1.5% power or shore power protecting the electrical system
from the possibility of simultaneous connection of both
D Cyclic cranking: 15 seconds on, 15 seconds off power sources. Available as a three-pole ship-to-shore
(3 cycles) switch.
D Faults with shutdown:
d High engine temperature Remote Digital Gauge
d Low oil pressure Allows starting/stopping from a location remote from the
d Loss of coolant generator set. Standard 76.2 mm (3 in.) dia. hole required
d Overcrank safety for mounting.
d Overspeed Oil Pressure Sender Kit
d Over/under voltage Provides sender necessary to make digital gauge
d Over/under frequency functional.
d Auxiliary fault
D Faults with warning: Remote Connection/Extension Harness
d Low battery voltage Provides wiring between the remote digital gauge and the
d High battery voltage ADC connector. Extension limited to a total of four kits
and 23 m (75 ft.). Available in 4.6 m (15 ft.) and 7.6 m
D Power requirements: (25 ft.) lengths.
d 12 or 24 VDC with fuse protection
d 200 mA @ 12VDC/100 mA @ 24 VDC 12-Inch Remote Wiring Harness
Equipped with a 12-pin connector on one end that
connects to the standard customer interface connector.
Equipped on the other end with leads for connection to
customer-supplied wiring.

G2-134 (10EOZD) 11/10a


KOHLER CO., Kohler, Wisconsin 53044 USA
Phone 920-457-4441, Fax 920-459-1646
For the nearest sales and service outlet in the
US and Canada, phone 1-800-544-2444
KohlerPower.com

ADV-7384-
DISTRIBUTED BY:

NOTE: Dimensions in [ ] are inch equivalents.

NOTE: This drawing is provided for reference only and is not


intended for installation planning. Contact your local
distributor for more detailed information.
E 2009 and 2010 by Kohler Co. All rights reserved.

G2-134 (10EOZD) 11/10a

You might also like