ECS 238
ECS226
BASIC SOLID
SOLID MECHANICS
MECHANICS
CHAPTER 4:
BUCKLING OF COLUMNS
BY
AIMI MUNIRAH BINTI JALILLUDDIN
WEEK 14
CONTENTS
1 Learning Outcomes
2 Introduction
3 CHAPTER 4: Buckling of Columns
a Effective Length
b Euler’s Formula
c Critical Buckling Stress
CHAPTER 4
BUCKLING OF COLUMNS
LEARNING OUTCOMES
At the end of this chapter, the student will able to:
o Understand the behavior of columns and concept
of critical load and buckling
o Determine the axial load needed to buckle a so-
called ‘ideal’ column
o Determine the ‘effective length’ of a column with
various end-conditions
o Design a realistic column against buckling
INTRODUCTION
• The failure of structural elements due to various forms – the
materials, type of loads, and conditions of support
• Ductile failure – ductile members may elongate or bend
excessively if overloaded, causing the structural member to pull
apart or collapse
• Most types of failure are avoided by analyzing and designing
the members so that their maximum stresses and maximum
deflections occur within tolerable limits.
• Two main concerns:
Strength – its ability to support a specified load without
experiencing excessive stresses
Stiffness – its ability to support a specified load without
undergoing unacceptable deformations or sudden change
in its configurations.
INTRODUCTION
Examples – building with columns, water tower legs,
truss members, bridge piers and frame members.
Strut – inclined members
Types of columns
Short column – fails by direct compression
- its length is lesser than the critical
buckling length
Slender column- fails by bucklings
- its length is greater than the
critical buckling length
INTRODUCTION
Column – vertical(compression) members
are usually found in load resisting
structures
Long slender members subjected to an axial
compressive force are called columns.
Lateral deflection that occurs is called
buckling.
The buckling of a column can lead to a
sudden and dramatic failure of a structure or
mechanism.
Critical load, Pcr is the maximum axial load
that a column can support when it is on the
verge of buckling as shown in Figure1(a).
(a) (b)
Any additional loading will cause the column
to buckle and therefore deflect laterally as Figure 1
shown in Figure 1(b).
INTRODUCTION
Buckling occurs when a long flexible member is
loaded longitudinally in compression and deflects
near the centre of its length with a considerable
amount of displacement as shown in figure below.
Figure: Buckling of a column
INTRODUCTION
Quite often the buckling of column can lead to
sudden and dramatic failure. And as a result,
special attention must be given to design of
column so that they can safely support the loads.
Buckling is not limited to columns.
Can occur in many kinds of structures
Can take many forms
Step on empty aluminum can
Major cause of failure in structures
COLUMN FAILURES DUE TO BUCKLING
NW March11 : ECS228 - Columns
CONCEPT OF STABILITY
(BUCKLING) OF A COLUMN
Factor of safety (FOS) – a safety margin given in design so that
the member will not fail when the load is increased beyond the
elastic limit or when the size is reduced
A structural member must be designed so that its ultimate load
is larger than the load the member is expected to carry.
This smaller load is known as the allowable load or working
load or design load.
ultimate load Pult
FOS = allowable load = P
all
FOS = ultimate stress σ ult
=
allowable stress σ all
FOS varies between 1.4 and 3
CONCEPT OF STABILITY
(BUCKLING) OF A COLUMN
Assumptions or limitations of Euler’s formula:
1. Axially loaded column – perfectly aligned with the axis of
the column
2. Column is perfectly straight – no initial buckling at all
3. Isotropic and homogeneous material – chemical and
mechanical properties are the same at any point of the
column
4. Material behaves within elastic properties
5. Both ends of the column support are pinned
EFFECTIVE LENGTH OF COLUMN
Critical buckling length = effective length, Le
Le is dependent on:
- The shape and size of the cross section
- The relationship between the length of the column and its
lateral dimensions
- The degree of fixity at the ends
No End Conditions Le
1 Both ends pinned 1.0 L
2 One end pinned and the other fixed 0.7L
in direction (Partially restrained)
3 Both ends fixed in direction 0.5L
(Fully restrained)
4 One end fixed in direction and the 2.0L
other is free
EFFECTIVE LENGTH OF COLUMN
(a) (b) (c)
(d)
Figure: Effective length
EULER’S FORMULA
Buckling eqn for column,
2 EI
Pcr
L2
Pcr = Euler critical buckling load or maximum
axial load on column just before it begins
to buckle. This load must not cause the
stress in column to exceed proportional
limit
E = Modulus of elasticity of material
I = Least second modulus of inertia for column’s
sectional area
L = Length of column
CRITICAL BUCKLING STRESS
The critical buckling stress
2E
P
σcr = cr
cr 2E
A cr
2
= π EI
L r 2
KL / r 2
AL2
radius of gyration of the column section, r = √ (I/A)
slenderness ratio, k = Effective length of the column, Le
Radius of gyration, r
EXAMPLE 1
SOLUTION
EXAMPLE 2
SOLUTION
EXAMPLE 3
The A-36 steel W20046 member shown in Fig. 13–8 is to
be used as a pin-connected column. Determine the
largest axial load it can support before it either begins
to buckle or the steel yields (y = 250 MPa). Given that
E = 200GPa.
SOLUTION
From Appendix B,
A 5890 mm 2 , I x 45.5 106 mm 4 , I y 15.3 106 mm 4
By inspection, buckling will occur about the y–y axis.
2 EI 2 200 106 15.3 104 1 / 10004
Pcr 1887.6 kN
L2 42
When fully loaded, the average compressive stress in the column is
Pcr 1887.6 1000
cr 320.5 N/mm 2
A 5890
Since this stress exceeds the yield stress,
P
250 P 1472.5 kN 1.47 MN (Ans)
5890
EXAMPLE 4
EXAMPLE 5
EXAMPLE 5
EXAMPLE 6
EXAMPLE 5
EXAMPLE 6
EXAMPLE 6
EXAMPLE 7
A W150-24 steel column is 8 m long and is fixed at its ends as
shown in Fig. 13–11a. Its load-carrying capacity is increased
by bracing it about the y–y (weak) axis using struts that are
assumed to be pin connected to its mid-height. Determine
the load it can support so that the column does not buckle
nor the material exceed the yield stress. Take Est = 200 GPa
and σY = 410 MPa.
SOLUTION
Effective length for buckling about the x–x and y–y axis is
KL x 0.58 4 m 4000 mm
KL y 0.78 / 2 2.8 m 2800 mm
From the table in Appendix B,
I x 13.4 106 mm 4
Iy 1.8310 mm
6 4
Applying Eq. 13–11,
2 EI 2 20013.4106
Pcr x 1653.2 kN (1)
KL 2
x
4000 2
2 EI 2 2001.83106
Pcr y 460.8 kN (2)
KL 2
y
2800 2
SOLUTION
By comparison, buckling will occur about the y–y axis.
The average compressive stress in the column is
Per 460.8103
cr 150.6 N/mm 2 150.6 MPa
A 3060
Since this stress is less than the yield stress,
buckling will occur before the material yields.
Thus, Pcr 461 kN (Ans)
From Eq. 13–12 it can be seen that buckling will always
occur about the column axis having the largest
slenderness ratio, since it will give a small critical stress
TUTORIAL
A 3m column with a pin-pin condition at its ends has cross-
section shown in Figure is constructed from 2 pieces of
timber. The timbers are nailed together so that they act as a
unit. Determine:
i. The slenderness ratio.
ii. The Euler’s buckling load (E = 13GPa)
iii. The axial stress in the column when the Euler load is
applied. 50mm
50mm 50mm
150mm
50mm
150mm
THE END