Planning, Analysis and Design of (C+G+7) Storey RCC Framed Residential Building Using Staad Pro. Paper

Download as docx, pdf, or txt
Download as docx, pdf, or txt
You are on page 1of 2

Analysis and Design of Storey RCC Framed

Abstract: The project comprises the development of plans, elevations, and


sectional view of a Commercial Reinforced Concrete building of ground floor,
using Auto-cad 2008. Structural loads (Gravitational loads only), Dead and Live
loads are only considered for the design of structure, and the loads considered are
as per IS: 875 – Part-I & II. The analysis and design of the building skeletal fame
is performed by using STAAD Pro V8i package for factored (Limit state of
strength) combination(s). The structural displacements in vertical and horizontal
directions of the building are permitted to the limitations as per IS: 456 – 2000, for
un-factored (Limit state of serviceability) combination(s).Structural elements like
Slab(s) are designed manually and foundation design is done using STAAD
foundation. The reinforcement details are furnished according to the code
provisions and presented in this report.

ABOUT STAAD PRO dynamic analysis from modal extraction to


time history and response spectrum analysis.
 STAAD Pro is a Structural Analysis and
design computer program originally In recent years it has become part of
developed by Research Engineers integrated structural analysis and design
International in Yorba Linda, CA. In late solutions mainly using an exposed API
2005, Research Engineer International was called Open STAAD to access and drive the
bought by Bentley Systems. program using an VB macro system
included in the application or other by
STAAD Pro allows structural engineers to including Open STAAD functionality in
analyse and design virtually any type of applications that themselves include suitable
structure through its flexible modelling programmable macro systems. Additionally
environment, advanced features and fluent STAAD Pro is added direct links to
data collaboration.  applications such as RAM Connection and
STAAD Foundation to provide engineers
STAAD Pro is one of the leading structural working with those applications which
analysis and design software which supports handle design post processing not handled
more than 100 steel, concrete and timber by STAAD Pro itself. Another form of
design codes and has the largest worldwide integration supported by STAAD Pro is the
user base. analysis schema of the CIM steel Integration
Standard, version 2 commonly known as
It can make use of various forms of analysis CIS/2 and used by a number modelling and
from the traditional 1st order static analysis, analysis applications.
2nd order p-delta analysis, geometric
nonlinear analysis or a buckling analysis. It Dead and live loads at Roof
can also make use of various forms of level:
Dead load of brick wall (230
mm thick) = 0.23*0.45*20

(Parapet wall)
= 2.07
N/m

Dead load of slab (125 mm


assuming) = 0.125*25

= 3.0 kN/m2

Water proofing
= 3.0kN/sq.m

Total floor load


= 3.125+3.0

= 6.125
2
kN/m

Live load (On floor,


accessible) = 1.5
kN/m2

You might also like