SECTION 1
1.3
APARTMENT DESIGN
BCA CLASS 2
CONSTRUCTION
DESIGN GUIDELINES
FOR SUSTAINABLE HOUSING & LIVEABLE NEIGHBOURHOODS
on behalf of the South Australian Housing Trust
Valid until July 2016
DESIGN GUIDELINES
FOR SUSTAINABLE HOUSING & LIVEABLE NEIGHBOURHOODS
1
1.3 APARTMENT DESIGN
CONTENTS
Introduction 5
Background 5
This Design Guideline 6
Medium Rise Building Form 6
High Rise Building Form 6
Healthy Living and Community Connectivity 6
Scope 7
Complementary Design Guidelines 8
Building Code of Australia (BCA) 8
Guiding Principles 12
References 38
Tables
Minimum Balcony Space for Apartment Projects 30
Figures
Figure 1: Renewal SA sketch proposal for Bowden Village showing
mix of dwelling types & sizes as well as distributed
open space 12
Figure 2: Contextual Assessment Plan 14
Figure 3: Maximise Solar Access for all Levels 23
Figure 4: Sketch of a Typical Balcony 31
Acronyms
Copyright
Although the SAHT owns copyright on this document on behalf of the Crown, it licenses its
contractors to use the latest available version for SAHT design or construction purposes, and
grants non-exclusive licences to others, as long as:
• They do not falsely claim copyright in the SAHTs’ work;
• They indemnify the SAHT and the government of South Australia against claims arising
from the use of SAHTs’ work.
Scope
The building types included in this Design Guideline include walk up flats
and apartments of Building Code of Australia Construction Classification
Class 2.
Recent Developments
In more recent times other options have been developed including:
• Laundry facilities included within bathroom areas;
• Open stair tower and deck access in small developments;
• Two level units accessed from the uppermost floor level;
• Direct access ground floor units with upper levels provided with a
paired (shared) access stair;
• Logan St, Adelaide: 16 units - various 1 & 2 bed walk-up and
townhouse units;
• An eight storey city building with a lift – Ifould Street, Adelaide; and
• Uno Apartments – Waymouth Street, Adelaide.
All recent apartments have been provided with individual balconies
with ground floor units provided with a private open space – Hallett
Street and Logan Street developments both in the City of Adelaide.
Upgraded 1950s walk up flats with new separate ground floor entrances
at Stow Court, Fullarton
Liveability
Housing should provide adequate private and communal storage
facilities of a minimum size of 2.3m2 internal space in addition to
clothes and linen storage.
Recommended standards for room sizes are contained in the design
guideline 1.4 Housing Accommodation Schedules and Adelaide City
Council Development Plan, and should vary according to the estimated
number of people accommodated as well as the number of bedrooms.
Structure Plan
Provide a structure of buildings and spaces within the development
to relate to others in the surrounding area in terms of:
• site layout
• movement routes within site
• existing street patterns in surrounding area, and
• provide networks of public spaces.
Community By-Laws
To achieve Socially Inclusive Management the Body Corporate must
provide a resident/tenant/owner education program on waste
minimisation and energy efficiency.
By-Laws for Community Title development are to be prepared
by Renewal SA in consultation with Community Housing bodies
involved to ensure that there are no anti-family provisions, or anti-
sustainability provisions which:
• restrict the use of balconies;
• limit the use of open space;
• minimise common property areas of communal space;
• restrict the type of households to non-family households;
• limit resident/tenant involvement in the maintenance and design
of open spaces particularly at entrances to individual dwellings at
ground level and entrances to groups of units in high-rise buildings
and entering into high cost landscape maintenance contracts;
• exclude normal activities by ‘gated’ communities signage;
• limit normal behaviour of children;
• provide for negative signage;
• discourage households to individualise their dwellings and
entrances with planter boxes and decorative elements;
• discourage clothes drying in private open spaces; and
• exclude small pets particularly for older residents.
Internal Circulation
Allow for generous, well designed staircases with views of (or open
to) access corridors and the external environment to encourage
increased activity as a desirable and pleasant alternative to using
lifts.
Corridors, stairs and lifts should be wide enough to move large
furniture items to apartments.
Core circulation spaces to serve groups of dwellings on each floor
with a maximum of 8-12 units on each level.
High density housing, Canberra
Source: Wendy Bell
Features
Provide attractive community focal points such as semi-private
central open space focusing on existing character trees or new
tree(s) on the site.
Facilitate arts, cultural and education projects that bring residents
together and provide opportunities for artistic and cultural
expression.
Energy Efficiency
Apartments must be designed and set out with dual aspect with
openable external windows, and doors to balconies to facilitate
cross-ventilation of indoor environments.
• provide standard sizes, materials and components and avoid
imported fittings such as lights for which globes are difficult to
source or have high energy use; and
• passive design of dwellings by orientation of living areas to the
north for winter sun and shading of northern and western windows
in summer; and sufficient thermal mass in external walls to limit
use of air-conditioners and mechanical heating.
Commentary
This commentary applies to new build apartment units built for the
SAHT. These new developments may be mixed in any one project for
rental use, community providers or for private sale. Design solutions
must allow for community strata titling.
Although these provisions are focused on new build units there are
implications for the upgrade of existing units managed by Renewal SA
and/orHousing SA.
Particular projects, as advised, may require additional features
in respect of energy efficiency ratings, roof water collection and
accessibility requirements.
External Spaces
SAHT flat and apartment development has been notable in the past
for its high quality landscape features. Many sites feature fine
stands of now mature native plantings and in some circumstances
rare exotic specimens. The amenity of the open space surrounding
these developments contributes to both the quality of apartment
living and assists in offsetting the inherent density of apartment
living.
All open space within a development must be designed in such a way
as to contribute to the overall amenity of the project, taking into
consideration maintenance requirements and public safety. Included
within these areas may be driveway access and both resident and
visitor carparking.
Site issues to be considered by designers and developers are set out
in the guidelien 2.2 Design Guidelines for Site Layouts.
Where possible new development should be located adjacent to
existing public open space in order to give residents opportunities
for self recreation, and to compensate for the limited open space
available within the project.
Notes:
• The Minimum Width allows for a component of outdoor furniture.
• For ground floor units 20m² private open space is an acceptable
minimum for all 1 and 2 bedroom units.
• Family housing (3 bedrooms and larger) would not be normally
included in above ground level group housing projects.
Environmental Sustainability
THe SAHT generally does not provide air-conditioning and prefers to
promote passive heating and natural ventilation.
Operation and management practices must be considered to keep
costs down over life of project. Security lighting should be reviewed
for ongoing operation. Large housing groups such as these offer
opportunities for innovative sharing and management of energy use.
Solar orientation of individual units must be addressed. Refer to the
guideline 2.4 Environmental Sustainability for more information.
Where called up, units are to be rated for Energy Efficiency at 6 stars
by FirstRate 5 or AccuRate or BERS, or in accordance with applicable
Balconies at Portrush Road,
BCA requirements.
Kensington 1995
Maintenance and sound transmission requirements given in the BCA
are to be met.
© Crown Copyright 30 Housing Design Guidelines
Government of South Australia Valid until July 2016
1.3 APARTMENT DESIGN 1
Cross Flow Ventilation
Double sided buildings are not encouraged as the presence of an enclosed
corridor or foyer will inhibit both through ventilation and access to natural
daylight to inner rooms. Acceptable design techniques can include
allowance for a diagonal cross-flow in corner units at the ends of buildings.
Within apartments it is important that ordinary openable windows are used
to allow for natural ventilation. It is not acceptable to rely on balcony
doorways, often a full height glazed sliding window, to provide natural
ventilation in living rooms. At the ground level full height “sliders” can
be perceived as a security issue, and at higher upper levels there can be
problems with sealing for draughts.
Rain Water
Where called up only (in NBESP projects), tanks totalling a minimum Pump Systems
of 2000 litre per unit are to be used to collect roof water from at Applicable where called up
least 80% of the roof and used to flush toilets. A pumped system will only. As the pump systems
be needed, with a mains water back up. run the toilets, the system
needs to be designed for
It should be noted that as buildings get more compact the roof ease of maintenance and
catchment area per dwelling unit reduces disproportionately so the replacement, and is to be
quantity available for capture may be equivalent to the roof area of sized to allow for filling
a single storey family house distributed over four apartments. of multiple toilets at the
same time. In addition
the use of more than one
Utility Metering pump to provide a back up
is preferred. A system to
All services entering a unit are to be individually metered, easily advise that one or all the
accessible and be able to be isolated at the unit. Where possible pumps has failed is required.
these are to be supplier’s meters, but where that is not possible local
meters may be used and read by the “strata manager”. Landlord
metering is required for services to public areas.
Kitchen Design
Set out of kitchens refer to the guideline 1.1 House Design Guide.
Kitchen Floor Finishes
Options for apartment design can include L shaped layouts. However
Sheet vinyl is to be provided.
straight line bench solutions are discouraged, as they can lead
This decision has been
to excessive travel and unnecessarily inefficient work practices. developed to meet customer
Overhead storage units can be considered. expectations for ease of
In some narrow building types the kitchen or meals preparation cleaning and appearance,
area will not be on an external wall. Nevertheless requirements for and performance criteria in
mechanical ventilation in the vicinity of the cooktop will need to respect of slip resistance.
be addressed. The design solutions will need to take into account The kitchen floor coverings
extract fan unit capacity and duct length and space provision for are to continue into any
horizontal or vertical locations for ducting to outside. For apartment alcoves provided including
buildings options for locating servicing conduits may be limited fridge spaces and dishwasher
due to forms of construction, and the fire separation and acoustic alcove (if provided). There
are particular requirements
requirements of class 2 building classification.
for upright cookers, refer to
An alternative to the provision of a ceiling mounted extract fan may separate note.
be the use of an over cook top range hood, subject to Renewal SA The SAHT has a supply
approval. Ductwork to the outside is essential. In smaller dwelling contract for floor coverings,
units the type and location of the ceiling mounted fire alarm further information is
Recirculating range hoods will not be acceptable in any available on request.
circumstances.
Floor Coverings
For retained rental projects the SAHT has a supply contract for floor
coverings. These include a range of vinyl and carpet products that are
normally installed after construction and prior to tenants moving into Wet Area Floor Tiles
the units. To maintain acoustic separation acoustic backed vinyl is to be SAHT approved floor tiles
specified in kitchen areas and carpet or acoustic backed vinyl in living must be used in units
and sleeping areas. retained for rental housing.
A range of approved
For the wet area floors the SAHT has a limited range of approved slip floor tiles is available as
resistant tiles. scheduled in the SAHT
Approved Products Register.
The register is available
Bathrooms separately on request.
Bathrooms in one and two bed apartments should be combined to This range of floor tiles was
developed to meet both
include all wet area facilities. This has design and construction
customer criteria for ease
advantages including the efficiency at combining plumbing services and
of cleaning and appearance,
wet-area construction within the one location. and performance criteria in
Refer to the guideline 1.4 Housing Accommodation Schedules for details. respect of slip resistance.
All apartments at ground floor or accessed by a lift should be set out For public liability reasons
in accordance with the guideline 2.3 SAHT Universal Housing Design no other products will be
Criteria. acceptable.
For similar reasons sheet
vinyl and other alternative
floor finishes are NOT
acceptable in wet areas.
Ceiling Heights
Where ceiling mounted sweep fans are to be provided a minimum
floor to ceiling height shall be 2550mm.
For non habitable rooms such as bathrooms and wet areas generally
minimum floor to ceiling height shall be 2250mm.