h17713 Dell Emc Unity XT Series Ss
h17713 Dell Emc Unity XT Series Ss
h17713 Dell Emc Unity XT Series Ss
Array Enclosure A 2U Disk Processor Enclosure (DPE) with twenty five 2.5” drives
All-Flash (F) models support 2.5” drives in 2U twenty five drive and 3U eighty drive trays.
Drive Enclosure (DAE - Hybrid models support 2.5“ drives in 2U twenty five drive and 3U eighty drive trays; and 3.5” drives in 3U fifteen drive
Disk Array Enclosure) trays.
Dell EMC Unity systems are powered by 2 power supplies (PS) per DPE/DAE. Each power supply can provide
power to the entire module if the peer PS has been removed or is faulted. DPE power during a power failure is
Standby Power System provided by a Battery Back Up (BBU) module. BBU is located within the SP enclosure and provides power to a
single module (power zone)
Total CacheA Up to 928 GBs Up to 1.39 TBs Up to 3.58 TBs Up to 6.76 TBs
Max Mezzanine cards per
ArrayB NA 2 2 2
Supported Media
System Usage/ Nominal Formatted DPE 25 X 2.5” 80 X 2.5” 15 X 3.5”
Type Interface
Category Purpose Capacity Capacity* 25 Drive Drive DAE Drive DAE Drive DAE
Virtualization Solutions
Dell EMC Unity offers support for a wide variety of protocol and advanced features available via various software suites
and packs including but not limited to:
• OpenStack Cinder Driver: For provisioning and managing block volumes within an OpenStack environment
• OpenStack Manila Driver: For managing shared file systems within an OpenStack environment
• Dell EMC Virtual Storage Integrator (VSI) for VMware vSphere™: For provisioning, management, and cloning
• VMware Site Recovery Manager (SRM) Integration: Managing failover and failback making disaster recovery rapid
and reliable
• Virtualization API Integration: VMware: VAAI and VASA. Hyper-V: Offloaded Data Transfer (ODX) and Offload
Copy for File
DIMENSIONS
Weight kgs/lbs empty 24.60/54.11 empty 25.90/57.10 empty 25.90/57.10 empty 25.90/57.10
Vertical size 2 NEMA units 2 NEMA units 2 NEMA units 2 NEMA units
1.56 x 106 J/hr, (1,474 Btu/hr) max at 4.43 x 106 J/hr, (4,207 Btu/hr) max at 1.01 x 106 J/hr, (959 Btu/hr) max at
Heat Dissipation 100 VAC 100 VAC 100 VAC
(operating maximum) 1.54 x 106 J/hr, (1,457 Btu/hr) max at 4.43 x 106 J/hr, (4,207 Btu/hr) max at 1.00 x 106 J/hr, (945 Btu/hr) max at
200 VAC 200 VAC 200 VAC
30 Apk “cold” per line cord, at any 45 Apk “cold” per line cord, at any 30 A max “cold” for ½ line cycle, per
In-rush Current
line voltage line voltage line cord at 240 VAC
Startup Surge Current 40 Apk “cold” per line cord, at any 120 Apk “hot” per line cord, at any 25 Amps peak max per line cord, at
line voltage line voltage any line voltage
AC Protection 10 A fuse on each power supply,
15 A fuse on each power supply, single line
single line
AC Inlet Type IEC320-C14 appliance coupler, per power zone
Ride-through Time 12 ms minimum 10 ms minimum 30 ms minimum
Current Sharing ± 5 percent of full load, between power supplies Droop Load Sharing
WEIGHT AND DIMENSIONS
Weight kg/lbs Empty: 10.0/22.1 Empty: 11.33/25 Empty: 14.5/32
Full: 20.23/44.61 Full: 58.9/130 Full: 30.8/68
Vertical size 2 NEMA units 3 NEMA units 3 NEMA units
Height cm/inches 8.46/3.40 13.21/5.20 13.33/5.25
Width cm/inches 44.45/17.5 44.70/17.6 44.45/17.5
Depth cm/inches 33.02/13 76.20/30 35.56/14
Note: Power consumption values for DPEs and DAEs are based on fully populated enclosures (power supplies, drives and I/O modules).
Cabinets
Standard 40U Cabinet
AC Line Voltage 200 to 240 VAC ± 10%, single-phase, 47 to 63 Hz
Power Configuration One, two, three or four power domains, each redundant
Power Inlet Count Two, four, six, or eight (two per domain)
Plug Types NEMA L6-30P or IEC309-332 P6 or IP57 (Australia)
1 Domain: 4,800 VA @ 200 VAC, 5,760 VA @ 240 VAC
Input Power Capacity 2 Domain: 9,600 VA @ 200 VAC, 11,520 VA @ 240 VAC
3 Domain: 14,400 VA @ 200 VAC, 17,280 VA @ 240 VAC
4 Domain: 19,200 VA @ 200 VAC, 20,040 VA @ 240 VAC
AC Protection 30 A site circuit breakers on each power branch
Height - 75 in (190.8 cm); Width - 24.0 in (61.1 cm); Depth - 39.0 in
40U Cabinet Dimensions
(99.2 cm); Weight Empty – 380 lb (173 kg)
Description Specification
Recommended Range Operation The limits under which equipment will operate 18°C to 27°C (64.4°F to 80.6°F) at 5.5°C
the most reliably while still achieving (59°F) dew.
reasonably energy-efficient data center
operation.
Continuous Allowable Range Operation Data center economization techniques (e.g. 5°C to 35°C (50°F to 95°F) at 20% to 80%
free cooling) may be employed to improve relative humidity with 21°C (69.8°F) maximum
overall data center efficiency. These dew point (maximum wet bulb temperature).
techniques may cause equipment inlet De-rate maximum allowable dry bulb
conditions to fall outside the recommended temperature at 1°C per 300m above 950m
range but still within the continuously allowable (1°F per 547 ft above 3117 ft).
range. Equipment may be operated without
any hourly limitations in this range.
Improbable Operation (Excursion Limited) During certain times of the day or year, 35°C to 40°C (with no direct sunlight on the
equipment inlet conditions may fall outside the equipment) at -12°C dew point and 8% to 85%
continuously allowable range but still within the relative humidity with 24°C dew point
expanded improbable range. Equipment (maximum wet bulb temperature). Outside the
operation is limited to ≤ 10% of annual continuously allowable range (10°C to 35°C),
operating hours in this range. the system can operate down to 5°C or up to
40°C for a maximum of 10% of its annual
operating hours. For temperatures between
35°C and 40°C (95°F to 104°F), de-rate
maximum allowable dry bulb temperature by
1°C per 175m above 950m (1°F per 319 ft
above 3117 ft).
Exceptional Operation (Excursion Limited) During certain times of the day or year, 40°C to 45°C (with no direct sunlight on the
ASHRAE 4 only equipment inlet conditions may fall outside the equipment) at -12°C dew point and 8% to 90%
continuously allowable range but still within the relative humidity with 24°C dew point
expanded exceptional range. Equipment (maximum wet bulb temperature). Outside the
operation is limited to ≤ 1% of annual continuously allowable range (10°C to 35°C),
operating hours in this range. the system can operate down to 5°C or up to
45°C for a maximum of 1% of its annual
operating hours. For temperatures between
35°C and 45°C (95°F to 104°F), de-rate
maximum allowable dry bulb temperature by
1°C per 125m above 950m (1°F per 228 ft
above 3117 ft).
Statement of Compliance
Dell EMC Information Technology Equipment is compliant with all currently applicable regulatory requirements for
Electromagnetic Compatibility, Product Safety, and Environmental Regulations where placed on market.
Detailed regulatory information and verification of compliance is available at the Dell Regulatory Compliance
website. http://dell.com/regulatory_compliance