A-Dec - Manual Cuspidor
A-Dec - Manual Cuspidor
A-Dec - Manual Cuspidor
CASCADE 7284
®
AND
RADIUS 7285
®
CUSPIDOR
85.2609.00
ALPHABETICAL
EQUIVALENT TO THE NUMERAL
OF THE MONTH MANUFACTURED
SERIAL (SN)
A January
NUMBER
B February
C March
D April
E May
F June
G July
H August MODEL (REF)
I September
NUMBER
J October
K November
L December SERIAL NUMBER
IDENTIFICATION
YEAR MANUFACTURED
Warranty:
A-dec warrants all products in this owner's guide against
defects in material or
workmanship for one year from time of delivery. A-dec's
sole obligation under the warranty is to provide parts for
the repair, or at its option, to provide the replacement
product (excluding labor). The buyer shall have no other
remedy. All special, incidental, and coincidental damages
are excluded. Written notice of breach of warranty must
be given to A-dec within the warranty period. The
warranty does not cover damage resulting from improper
installation or maintenance, accident or misuse. The
warranty does not cover damage resulting from the use of
cleaning, disinfecting or sterilization chemicals and
processes. The warranty also does not cover light bulbs.
Failure to follow instructions provided in the A-dec
owner's guide (operation and maintenance instructions)
may void the warranty. A-dec warrants A-dec dental chair
cylinders, both lift and tilt, for ten years from the date of
purchase of the chair or the cylinder. This warranty is
retroactive to A-dec chair cylinders already in the field.
The warranty covers chair cylinders A-dec finds to have
manufacturing related irregularities. Stool cylinders are
covered under A-dec's one-year warranty.
Return Policy:
U.S. and Canadian dealers wishing to return overstock
(unopened) merchandise to A-dec for credit consideration
must include a copy of the original invoice number. A
return authorization form from an A-dec Territory
Manager must be included with serial numbered
equipment or A-dec/W&H handpieces. A 15% restocking
fee will be assessed. Merchandise that cannot be returned
for credit includes parts assembled to the dental unit,
chair, light, or dental furniture; obsolete parts; and
specials. Dental furniture cannot be returned for credit.
Standard color upholstery ordered for obsolete chairs or
stools cannot be returned for credit. In the case of a
defective warranty item, a copy of the replacement in-
voice, serial number of the unit under which it was
replaced, and a description of the symptoms of the
defect must be returned with the part to:
A-dec Inc. 2601 Crestview Drive,
Newberg, Oregon 97132, USA.
Cascade 7284 and Radius 7285 Cuspidor
v
Cascade 7284 and Radius 7285 Cuspidor
CONTENTS
About Your Cuspidor .............................. 2
Cuspidor Controls ................................. 3
Touch Pad (optional) ............................... 4
Master On/Off Toggle .............................. 4
Cuspidor Limit Switch ............................. 5
Gravity Drain Cleaning ............................ 5
Cleaning the Cuspidor ............................. 6
Care Instructions .................................. 7
Bowl Rinse Adjustment ........................... 7
Bowl Rinse Flow Adjustment ................ 7
Bowl Rinse Time Adjustment ................ 8
Cup Fill Adjustment ............................... 9
Utility Controls ................................... 10
Maintenance ...................................... 11
Adjustments and Specifications ................ 11
Identification of Symbols ........................ 12
Classification of Equipment (EN 60601-1) ..... 12
1
Cascade 7284 and Radius 7285 Cuspidor
CONTOURED
WATER SPOUT
BOWL
SPOUT
CUP FILL
CUSPIDOR
BUTTON BOWL RINSE HOUSING
BUTTON
2
Cascade 7284 and Radius 7285 Cuspidor
Cuspidor Controls
Cup Fill Button. Allows water to flow into a cup.
When your cuspidor has an automatic timer, press
the button once and water will flow for
approximately four seconds. If you have a manual
cuspidor, water will flow as long as the button is
pressed. (Refer to page 9 for cup fill adjustments.)
Bowl Rinse Button. Starts the timed bowl rinse.
The bowl rinse provides rinse water for the cuspidor
bowl. (Refer to page 7 for bowl rinse flow adjust-
ments.)
Bowl Rinse Time Adjustment. Adjusts the length
of time that water flows to the bowl rinse. (Refer to
page 8 for bowl rinse time adjustments.)
3
Cascade 7284 and Radius 7285 Cuspidor
TOGGLE ON
CONTROL HEAD
TOGGLE ON
POST BOX TOGGLE ON
MASTER SERIES
TOUCH PAD
4
Cascade 7284 and Radius 7285 Cuspidor
5
Cascade 7284 and Radius 7285 Cuspidor
Caution
Do not empty the bowl screen into your cuspidor. Doing
so could plug the cuspidor drain.
CONTOURED
WATER SPOUT BOWL
SCREEN
Caution
After cleaning, always install the bowl screen in the
cuspidor bowl drain to prevent debris from plugging the drain.
6
Cascade 7284 and Radius 7285 Cuspidor
Care Instructions
For recommended asepsis instructions, refer to
your Equipment Asepsis Owner’s Guide, A-dec
Publication No. 85.0696.00.
POST BOX
INDICATOR
SIDE COVER
DOT
BOWL
RINSE FLOW
ADJUSTMENT
ADJUSTMENT SCREW
8
Cascade 7284 and Radius 7285 Cuspidor
9
Cascade 7284 and Radius 7285 Cuspidor
Utility Controls
The air and water manual shutoff valves, filter and
regulator package, as well as any vacuum or drain
outlets, are located in the floor box mounted over
the office plumbing on the floor or wall. If you have
a Cascade 7284 Cuspidor, some controls are located
in the post box at the side of the chair.
Refer to the Floor Boxes Owner’s Guide (A-dec
Publication No. 85.2611.00) for complete
information about the floor box.
10
Cascade 7284 and Radius 7285 Cuspidor
Maintenance
Gravity Drain Cleaning ................................page 5
Cleaning the Cuspidor.................................page 6
Care Instructions
Equipment Asepsis
Owner’s Guide ..............................85.0696.00
Parts
Maintenance Parts
Owner’s Guide ..............................85.2634.00
11
Cascade 7284 and Radius 7285 Cuspidor
12
Cascade 7284 and Radius 7285 Cuspidor
Identification of Symbols
Symbol Description
Recognized by Underwriters Laboratories Inc. with respect to electric shock, fire and mechanical hazards
only in accordance with UL 60601-1 (2601-1) and under mutual recognition agreement with CAN/CSA C22.2,
No. 601.1.
Classified by Underwriters Laboratories Inc. with respect to electric shock, fire and mechanical hazards
only in accordance with UL 60601-1 (2601-1) and under mutual recognition agreement with CAN/CSA C22.2,
No. 601.1.
Attention, consult accompanying documents. No user servicable parts . Attention, line voltage. Only
licensed electrician should remove cover.
Class II equipment.
Caution: Metal surfaces can be hot during and following the dry cycle.
Flammable Not suitable for use in the presence of a flammable anesthetic mixture with air, oxygen, or nitrous
Gasses: oxide, where such gasses may accumulate in concentration (closed space).
13
Cascade 7284 and Radius 7285 Cuspidor
Electrical Rating
Type Specification
Volts 100/110-120/220-240 VAC
Frequency 50-60 Hz
Current As configured and specified in equipment manual (products labeled 15A or greater require dedicated
circuit, identified in distribution panel).
Environmental Specifications
Temperature/Humidity Specification
Storage/Transportation -40°C to 70°C (-40°F to 158°F) - Relative humidity: 80% for up to 31°C, decreasing
Temperature: linearly to 50% at 40°C.
Operating Temperature: 10°C to 40°C (40°F to 104°F) - Relative humidity: 80% for up to 31°C, decreasing
linearly to 50% at 40°C.
Indoor Use: Altitude up to 2,000M (6,563 ft.), installation category II, pollution degree 2.
(UL 61010A-1 and CAN/CSA C22.2, No. 1010.1-92 only)
14
Notes
USA and Canada
2601 Crestview Drive
Newberg, Oregon 97132 USA
Phone: 1-800-547-1883
1-503-538-7478
Fax: 1-503-538-0276
www.a-dec.com
International
Phone: 1-503-538-9471
Fax: 1-503-538-5911
Distribution Centers
A-dec Australia
41-43 Bowden Street
Alexandria, NSW 2015, Australia
Phone: 61-(0)2-9699 4600
Fax: 61-(0)2-9699 4700
www.adec.com.au