Catalogue en 50hz
Catalogue en 50hz
Catalogue en 50hz
WHO WE ARE
WE WANT TO CONTINUE THAT WHICH WAS STARTED MANY YEARS
AGO BY VINICIO METTIFOGO, FOUNDER AND PIONEER.
products
pag. 11
E-MXP, E-MXA, E-NGX NEW pag. 147
MXV(EI), MXVL
NEW
Pressurized system Vertical multi-stage
with integrated control stainless steel pumps AISI 304, AISI 316L
products
pag. 16 E-MPS pag. 175 SPA Compact Spa
NEW
Pressurized system Self-draining whirpool pumps
with integrated control
pag. 19
NM, NMD pag. 177 MPC Compact Pool
Close coupled centrifugal pumps Self-priming swimming pool pumps
with threaded ports
NEW NEW
pag. 31
NM(EI), NMS pag. 181
NMP
Close coupled centrifugal pumps Self-priming centrifugal pumps
with flanged connections with built-in strainer
pag. 49
NM4(EI), NMS4 pag. 185
PF
Close coupled centrifugal pumps Pre-filters in stainless steel
n = 1450 rpm
pag. 115
MXH(EI), MXHL pag. 199
CT
Horizontal multi-stage Peripheral pumps
stainless steel pumps AISI 304, AISI 316L
pag. 135
MPSU pag. 213
NGL
Vertical multi-stage close coupled Self-priming pumps
stainless steel pumps
pag. 217
NGX pag. 269
GM 50
Self-priming pumps Submersible sewage and drainage pumps
pag. 237
GM 10 NEW pag. 373
MP
Submersible drainage pump Multi-stage submersible
clean water pumps
pag. 239
GXR, GXV pag. 377
MPS
Submersible stainless steel pumps Multi-stage submersible
clean water pumps
NEW
pag. 249
GX ZERO pag. 381
MXS
Submersible clean water pumps Stainless steel multi-stage submersible
clean water pumps
pag. 251
GQR NEW pag. 385
SD, SDP, SDN
Submersible drainage pumps Submersible borehole pumps
for 4”and 6” wells
pag. 255
GX 40 NEW pag. 402
SDX
Submersible stainless steel pumps Stainless steel submersible borehole
pumps for 6” and 8” wells
pag. 259
GQS, GQV pag. 423
SDS
Submersible sewage and NEW Submersible borehole pumps
drainage pumps for 6” - 8” and 10” wells
pag. 265
GQN pag. 435
CS-R
Submersible sewage and Submersible motors
drainage pumps for 4” - 6” - 8” and 10” wells
INDEX
pag. 447
NCE
Heating and conditioning
pag. 497
IDROMAT
Electronic regulator for pumps
pag. 501
EASYMAT
Variable speed system driven
by frequency converter
pag. 505
I-MAT NEW
pag. 509
BS
Pressure boosting sets
pag. 595
EJ, DJ, EDJ
UNI-EN 12845 units for feeding
fire-extinguishing systems
pag. 601
QM, QT
Control panels
pag. 622
Accessories
Accessories for pumps
pag. 628
4
3
PREVALENZA MANOMETRICA IN
4
ASPIRAZIONE (m.c.a.)
5
A
A TIC
6
A PR
CURV
Technical appendix
7
I CA
9 TEO R
CURVA
10
11
0 10 20 30 40 50 60 70 80 90 100 110
TEMPERATURA ACQUA IN GRADI CENTIGRADI
products
ENERGY
EFFICIENCY
COMPACT
DESIGN
7
03/2021
Construction
Self-priming booster set with built in frequency converter.
products MÈTA is a plug and play solution, the pump is equipped with an
integrated pressure transducer, an integrated check valve and a
built-in pressure vessel.
The VSD controls the start and stop of the pump and allows to
keep a constant pressure.
Applications
For water supply.
For domestic use, for garden use and irrigation.
Features
• integrated frequency converter
• built-in pressure vessel
• high efficiency asynchronous single-phase motor
• motor power control
• programmable re-start pressure
• no hydraulic losses due to the measuring devices
• voltage and current control
• monitoring of maximum starting current
EASY TO INSTALL
Plug And Play solution
Protections
• dry-run protection
ECONOMIC SAVING • detects the presence of air in the pump casing
IE4 high efficiency asynchronous single-phase motor • overload control and overheating motor control
• pump blockage
Up to 400W less energy consumption compared to a standard
• power supply control
solution
• starts per hour control
• detects small leakages in the system
EASY TO USE
Equipped with a programmable software and, thanks to the
analogic pressure sensor, the product allows to set the restart
pressure.
Operating conditions
Liquid temperature: 0 °C to +35 °C.
Ambient temperature up to +40 °C.
Maximum permissible pressure in the pump casing: 8 bar.
Continuous duty.
Materials
Component Material
Pump casing Cr-Ni steel 1.4301 EN 10088 (AISI 304) Motor
Casing cover Cr-Ni steel 1.4301 EN 10088 (AISI 304) 2-pole induction motor.
Pump Shaft Cr-Ni steel 1.4305 EN 10088 (AISI 303) Nominal speed 4500 rpm
Motor: variable speed
Suction casing PPO-GF20 (Noryl)
Frequency: 50 Hz
Stage casing PPO-GF20 (Noryl)
Single-phase 220-240V~50Hz/220V~60Hz, with thermal protector.
Impeller Cr-Ni steel 1.4301 EN 10088 (AISI 304) Cable: H07RN8-F, 3G1,5 mm2, length 1,5 m, with plug
Membrane Butyl CEIUNEL 47166.
Tank cover POM - POLYACETAL Insulation class F.
Membrane cap POM - POLYACETAL Protection IP X4.
Non-return valve POM - POLYACETAL Constructed in accordance with: EN 60034-1;
Plug Cr-Ni steel 1.4305 EN 10088 (AISI 303) EN 60335-1, EN 60335-2-41.
Mechanical seal Carbon - Ceramic - NBR
8
Variable speed pressure boosting
system with integrated control
60
50
set point max 4,7 bar
40
set point 3.5 bar
Hm
30
10
0
0 m3/h 2 4 6 8 10
Q
0 l/min 40 60 80 100 120 140 160
440 161
Net weight 12,44 kg
With cable length: 1,5 m G1
234,5
G1
235
116
10
8 9,5 30
155 33 112
250 146
9
Variable speed pressure boosting
system with integrated control
Control Panel
P460.REV02
products
10
03/2021
Construction
Easy to install, compact and plug and play pressurized system
with integrated pressure transducer for automatic control of
products starting/stopping of the pump when utilization points are
opened/closed with a integrated non-return valve into the pump
suction.
Pumps:
E-MXP: version with multistage pumps
E-NGX: version with self-priming pumps
E-MXA: version with self-priming multistage pumps
Applications
For water supply.
For domestic use, for garden use and irrigation.
Features
• high efficiency asynchronous single-phase motor
• capacitor less stressed in voltage
• uniform and lower motor temperature
• motor power control
• programmable re-start pressure
• programmable stop pressure
• no hydraulic losses due to the measuring devices
• voltage and current control
• monitoring of maximum starting current
EASY TO INSTALL
Plug And Play solution
Materials
Component Material Motor
2-pole induction motor, 50 Hz (n ≈ 2800 rpm).
Pump casing Cr-Ni steel 1.4301 EN 10088 (AISI 304)
Single-phase 230 V ± 10%, with thermal protector.
Casing cover Cr-Ni steel 1.4301 EN 10088 (AISI 304) Capacitor inside the terminal box.
Pump Shaft Chrome steel 1.4104 EN 10088 (AISI 430) Cable: H07RN-F, 3G1,5 mm2, length 1,5 m, with plug CEI-UNEL
47166.
Plug Cr-Ni steel 1.4305 EN 10088 (AISI 303)
Insulation class F.
Suction casing (E-MXA) PPO-GF20 (Noryl) Protection IP X4.
Stage casing (E-MXA,E-MXP) PPO-GF20 (Noryl) Constructed in accordance with: EN 60034-1;
EN 60335-1, EN 60335-2-41.
Impeller PPO-GF20 (Noryl)
Diffuser (E-NGX) PPO-GF20 (Noryl)
Ejector (E-NGX) PPO-GF20 (Noryl)
Mechanical seal Carbon - Ceramic - NBR
11
E-MX, E-NG 1-pump pressurized system
with integrated control
P1 Max. power input. Test results with clean cold water, without gas content. + 0,5 m security margin on NPSH-value is necessary.
P2 Rated motor power output. Tolerances according to UNI EN ISO 9906:2012
420
145 Net
TYPE weight
G1 161
kg (1)
E-MXPM 203-PCD 9,5
E-MXPM 204-PCD 10,8
G1
9 30
E-NGXM 3/100-PCD 10,0
95 8 112.5 E-NGXM 4/100-PCD 10,9
240 146 (1)
With cable length: 1,5 m
12
E-MX, E-NG 1-pump pressurized system
with integrated control
E-MXPM
50
40
H m
30
20
205 404
204
10 403
203
0
0 1 2 3 4 5 6 7
Q m 3/h
50
E-NGXM
40
30
3-100
20
2-80
4-110
10
0 0,5 1 1,5 2 2,5 3 3,5 4 4,5 5
Q m 3/h
50
E-MXAM
40
30
H m
20
0
0 1 2 3 4 5 6 7
Q m 3/h
13
BS2F 2E 2-pumps pressurized system
with integrated control
450
G 1 1/2
G2
625
248
179
250 400
14
BS2F 2E 2-pumps pressurized system
with integrated control
60
BS2F 2E-MXPM 2
50
40
H m
30
20
205
204
10
203
0
0 2 4 6 8 10 12 14
Q m 3/h
60
BS2F 2E-MXPM 4
50
40
H m
30
20
404
10 403
0
0 2 4 6 8 10 12 14
Q m 3/h
15
03/2021
Construction
5” Close coupled multi-stage submersible pumps. Easy to
install, compact and plug and play with integrated pressure
products transducer for automatic control of starting/stopping of the pump
when utilization points are opened/closed with a integrated non-
return valve.
Applications
For water supply from wells, tanks or reservoirs.
For domestic, civil and industrial applications, for garden use,
irrigation and rain water harvesting systems.
Features
• high efficiency asynchronous single-phase motor
• capacitor less stressed in voltage
• uniform and lower motor temperature
• motor power control
• programmable re-start pressure
EASY TO INSTALL • programmable stop pressure
Plug And Play solution • no hydraulic losses due to the measuring devices
• voltage and current control
• monitoring of maximum starting current
ECONOMIC SAVING
High efficiency asynchronous single-phase motor
24 % less energy consumption compared to a standard pump
Protections
• dry-run protection
• overload control and overheating motor control
EASY TO USE • pump blockage
Equipped with a programmable software and, thanks to the • power supply control
analogic pressure sensor, the product allows to set the restart • starts per hour control
pressure. An ideal solution which allows to reduce or remove
the need of a expansion tank
Operating conditions
Water temperature up to 35 °C.
Materials Minimum internal diameter of well: 140 mm.
Minimum immersion depth: 100 mm.
Component Material Maximum immersion depth: 20 m (with suitable cable length).
Delivery casing Continuous duty.
External jacket
Chrome-nickel steel 1.4301 EN 10088 (AISI 304)
Suction strainer
Motor jacket Motor
Non-return valve POM - POLYACETAL 2-pole induction motor, 50 Hz (n ≈ 2800 rpm).
Stage casing Single-phase 230 V ± 10%, with thermal protector.
PPO-GF20 (Noryl) Incorporated capacitor.
Impeller
Cable: - Pump 07BB-F, 3G1+4x0,34 mm2, length 23 m.
Shaft Chrome-nickel steel 1.4301 EN 10088 (AISI 304)
- Power supply cable H07RN8-F, 3G1,5 length 1,5 m
Capacitor cover with plug CEI-UNEL 47166.
Oil chamber cover PPS Polymer (Grivory) Insulation class F.
Preload ring stages
Support ring preload Protection IP X8 (for continuous immersion).
Upper mechanical seal Steatite, carbon, NBR Triple impregnation humidity-proof dry winding.
Lower mechanical seal Carbon, silicon carbide, NBR Constructed in accordance with EN 60335-2-41.
Seal lubrication oil Oil for food machinery and pharmaceutic use
16
E-MPS Multi-stage submersible clean water
pumps with integrated control
P1 Max. power input. P2 Rated motor power output. Tolerances according to UNI EN ISO 9906:2012 Test results with clean cold water, without gas content.
118.20
G 1 1/4
ISO 228
116.20
18.00
56.12 7
4.40
fM fM Pesoweight
Net Netto
TYPE
TIPO
mm kg 1)
(1)
With cable length: 23 m
133
17
E-MPS Multi-stage submersible clean water
pumps with integrated control
ft ft
305 50
50
505 150
150
304
40 40
504
30 100 30 100
20 20
50 50
10 10
0 0 0 0
0 m 3/h 1 2 3 4 5 0 m3/h 2 4 6 8
Q Q
0 l/min 20 40 60 80 0 l/min 50 100
Installation
1. Control box
1 2. Delivery pipe
7 3. Safety rope
4. Pressure gauge
5. Air vent valve
4 5 3 6. Gate valve
7. Pressure tank
2
6
max 20 m
0.5 m
min
140 mm
min 3.93.007/3
3.93.007/1 3.93.007/2
18
03/2021
Construction
Close-coupled, centrifugal pumps; electric motor with
extended shaft directly connected to the pump.
NM: single-impeller
NMD: with two back-to-back impellers (with axial thrust balancing).
Connections: threaded ports ISO 228/1 (BS 2779).
NM, NMD: version with pump casing and lantern bracket in cast iron.
B-NM, B-NMD: version with pump casing and lantern bracket in bronze.
(the pumps are supplied fully painted).
Applications
For clean liquids without abrasives, which are non-aggressive for
the pump materials ( solids content up to 0.2%).
For water supply.
For heating, air-conditioning, cooling and circulation plants.
For civil and industrial applications.
For fire fighting applications. For irrigation.
Operating conditions
Liquid temperature from -10 °C to +90 °C.
Ambient temperature up to 40° C.
Total suction lift up to 7 m.
Maximum permissible working pressure up to 10 bar
(16 bar for pumps NMD 25/190; NMD 32/210; NMD 40/180).
Continuous duty.
The electropumps NM, B-NM series comply with the European Regulation no.
Motor
2-pole induction motor, 50 Hz (n ≈ 2900 rpm).
547/2012.
NM, NMD: three-phase 230/400 V ± 10% up to 3 kW;
Materials 400/690 V ± 10% from 4 to 9,2 kW;
NMM, NMDM: single-phase 230 V ± 10%, with thermal protector.
Components NM, NMD B-NM, B-NMD Insulation class F. Protection IP 54.
Pump casing Cast iron Bronze Motor suitable for operation with frequency converter from 1,1 kW.
Lantern bracket GJL 200 EN 1561 G-Cu Sn 10 EN 1982 Classification scheme IE3 for three-phase motors from 0,75 kW.
Impeller Brass P- Cu Zn 40 Pb 2 UNI 5705 Constructed in accordance with EN 60034-1; EN 60034-30-1.
NM 17 Cast iron Bronze EN 60335-1, EN 60335-2-41.
GJL 200 EN 1561 G-Cu Sn 10 EN 1982
Shaft Cr steel AISI 430 Special features on request
Cr Ni Mo steel - Other voltages. - Frequency 60 Hz (as per 60 Hz data sheet).
Cr Ni steel AISI 303
AISI 316 - Protection IP 55. - Special mechanical seal
1,1 -1,5 - 2,2 kW
NM 6 Cr steel AISI 430 - Higher or lower liquid or ambient temperatures.
- Motor suitable for operation with frequency converter up to 0,75 kW.
Mechanical seal Carbon - Ceramic - NBR
20
5
4
1 m 3/h 2 3 4 5 6 7 8 9 10 20 30 40 50 100
Q l/min 30 40 50 100 150 200 300 400 500 1000 1500
72.820.C
19
NM, NMD Close Coupled Centrifugal Pumps
with threaded ports
Q
P2 m3/h 1 1,2 1,5 1,89 2,4 3 3,6 4,2 4,8 5,4 6 6,6 7,5 8,4
NM
kW HP l/min 16 20 25 31,5 40 50 60 70 80 90 100 110 125 140
NM 1/AE ● 0,37 0,5 22 21,6 21,3 20,9 20,3 19,4 18,1 16,3
NM 2/B/A ● 0,55 0,75 27 26,5 26 25,5 25 24 23 22 20
NM 2/S/A ● 0,55 0,75 31 30,5 30 29 27,5 25,5 23,5 20 16
NM 2/A/B ● 0,75 1 H 33,5 33 32,5 32 31,5 30,5 29,5 28,5 27 26 24
NM 6/B ● 0,75 1 m 30,5 30 29,5 28,5 27,5 26,5 25,5 24 22 18
NM 6/A ● 1,1 1,5 35,5 35,2 34,7 34 33 32 30,5 29 27 23,5 19*
NMM 3/CE 1,1 1,5 37,5 37,5 37 36,5 36 35 34 32
NM 3/C/A 1,1 1,5 37,5 37,5 37 36,5 36 35 34 32 30,5 28,5
NMM 3/BE 1,5 2 42 42 41,5 41 40,5 40 39 37 35 32
NM 3/B/A 1,5 2 47 47 46,5 46 45,5 45 44 43 41,5 40 37,5 33 26
NMM 3/A/A 1,8 2,5 47,5 47,5 47 46,5 46 45,5 44,5 43,5 42 40,5 38 33,5 26,5
NM 3/A/B 2,2 3 56 55,5 55,5 55 54,5 53,5 52,5 51,5 50 48 46 42 36
Q
P2 m3/h 1 1,2 1,5 1,89 2,4 3 3,6 4,2 4,8 5,4 6 6,6 7,5 8,4
B-NM NM
B-NMD NMD kW HP l/min 16 20 25 31,5 40 50 60 70 80 90 100 110 125 140
B-NMD 20/110B/A ● NMD 20/110B/A ● 0,45 0,6 33 32 31 29 26,5 23 18
B-NMD 20/110Z/A ● NMD 20/110Z/A ● 0,55 0,75 37 36 35 33 30,5 27,5 23 18
B-NMD 20/110A/B ● NMD 20/110A/B ● 0,75 1 43 42 40,5 39 36,5 33 29 25
B-NMDM 20/140BE NMDM 20/140BE 1,1 1,5 H 52 51,5 51 50 48,5 47 45
B-NMD 20/140B/A NMD 20/140B/A 1,1 1,5 m 53 52,5 52 51 50 48 46 43,5 40
B-NMDM 20/140AE NMDM 20/140AE 1,5 2 57,5 57 56,5 55,5 54 51,5 49 46 43 40 36
B-NMD 20/140A/A NMD 20/140A/A 1,5 2 67 66,5 66 64,5 63 61,5 59 57 53,5 50 46
B-NM 20/160BE ● NM 20/160BE ● 0,75 1 30,5 30 29,5 28,5 27,5 26,5 25,5 24 22
B-NM 20/160A/A ● NM 20/160A/A ● 1,1 1,5 36 35,5 35 34,5 33,5 32 30,5 29 27
Q
B-NM NM P2 m3/h 2,4 3 3,6 4,8 6 6,6 7,5 8,4 9,6 10,8 12 13,2 15 16,8 18
B-NMD NMD kW HP l/min 40 50 60 80 100 110 125 140 160 180 200 220 250 280 300
B-NM 25/12B/A ● NM 25/12B/A ● 0,55 0,75 20 19,9 19,8 19,3 18,5 18 17,3 16,3 15 13,2 11
B-NM 25/12A/B ● NM 25/12A/B ● 0,75 1 23,5 23,4 23,3 22,9 22,1 21,7 20,9 20 18,7 17,1 15,2
B-NM 25/160B/A ● NM 25/160B/A ● 1,1 1,5 31 30,7 30 28,5 28 27 26 23
B-NM 25/160A/A ● NM 25/160A/A ● 1,5 2 36,5 36,2 35,5 34,5 34 33,5 32,5 31 28,5 26
B-NM 25/200B/C NM 25/20B/C 2,2 3 42,2 41,9 41,4 40,7 40,2 39,7 39 37,9 36,7 35,2 33,4
H
B-NM 25/200A/B NM 25/20A/B 3 4 m 49,9 49,8 49,4 48,9 48,5 48,1 47,5 46,6 45,6 44,4 43 40,8 37,9
B-NM 25/200S/C NM 25/20S/C 4 5,5 57,4 57,3 57 56,8 56,5 56,2 55,8 55,1 54,3 53,2 52 49,9 47,2 44,9
B-NMD 25/190C/B NMD 25/190C/B 2,2 3 62 60,5 59 55,5 51 48,5 44 38
B-NMD 25/190B/A NMD 25/190B/A 3 4 76 75 74 70 66 64 60 54 46
B-NMD 25/190A/B NMD 25/190A/B 4 5,5 98 97 96 93,5 90 88 84 79 70
Q
P2 m3/h 6,6 7,5 8,4 9,6 10,8 12 13,2 15 16,8 18,9 21 24 27 30
NM
kW HP l/min 110 125 140 160 180 200 220 250 280 315 350 400 450 500
NM 10/FE ● 0,55 0,75 12,5 12,5 12 11,5 11 10 9 7,5
NM 10/DE ● 0,75 1 18 18 17,5 17 16,5 16 15,5 14
NM 10/A/A ● 1,1 1,5 23 23 22,5 22 21,5 21 20,5 19
NM 10/S/A ● 1,5 2 23,5 23,5 23 22,5 22 21,5 21 20,5 19 18,5 16,5 13
NMM 11/BE 1,5 2 26,5 25,5 25 24 23 22,5 21,5 19,5 17,5
H
NM 11/B/A 1,5 2 m 29,5 29,5 29 28,5 27,5 27 26 25* 22,5*
NMM 11/A 1,8 2,5 30,2 30,1 29,8 29,4 28,8 28,1 27,4 26 24,5
NM 11/A/B 2,2 3 35,5 35,5 35 34,5 34 33,5 33 32* 30*
NM 12/D/B 2,2 3 38 37,5 37 36 35 33,5 32
NM 12/C/A 3 4 45 44,5 44 43,5 42,5 41 40 38 36
NM 12/A/B 4 5,5 57,5 57 56 55,5 55 54,5 53,5 51,5 49
20
NM, NMD Close Coupled Centrifugal Pumps
with threaded ports
Q
P2 m3/h 5,4 6 6,6 7,5 8,4 9,6 10,8 12 13,2 15 16,8 18,9 21 24
B-NMD NMD
kW HP l/min 90 100 110 125 140 160 180 200 220 250 280 315 350 400
B-NMD 32/210D/B NMD 32/210D/B 4 5,5 71 69 67,5 65 62,5 58 53 46 37*
B-NMD 32/210C/A NMD 32/210C/A 5,5 7,5 84 83 82 81 79 76 73 69 64* 54*
B-NMD 32/210B/A NMD 32/210B/A 7,5 10 104 103 102 100 98 95 92 88 84* 76*
B-NMD 32/210A/B NMD 32/210A/B 9,2 12,5 H 114 113 112 110 108 105 103 99 96* 90*
B-NMD 40/180D/B NMD 40/180D/B 4 5,5 m 60 59,5 57 56 53 51,5 48 44 39 34* 25*
B-NMD 40/180C/A NMD 40/180C/A 5,5 7,5 69 68 67 66 64,5 63 60 57 53 48* 40*
B-NMD 40/180B/A NMD 40/180B/A 7,5 10 87 86 85 84 82,5 81 78 75 71 66* 59*
B-NMD 40/180A/B NMD 40/180A/B 9,2 12,5 94 93 92 91 89,5 88 85 82 78 74* 67*
Q
P2 m3/h 21 24 27 30 33 37,8 42 48 54 60 66 75 84 96
B-NM NM
kW HP l/min 350 400 450 500 550 630 700 800 900 1000 1100 1250 1400 1600
B-NM 17/H/A ● NM 17/H/A ● 1,1 1,5 9,5 9,2 9 8,6 8,2 7,5 6,7 5,5 3,5*
B-NM 17/G/A ● NM 17/G/A ● 1,5 2 H 12 11,7 11,5 11,2 11 10,3 9,7 8,5 7* 4*
B-NM 17/F/B NM 17/F/B 2,2 3 m 16 16 15,5 15 14,5 14 13 11,5* 10* 8*
B-NM 17/D/A NM 17/D/A 3 4 18 18 17,5 17 16,5 15,5 14* 13* 11,5*
NM, NMD Standard construction. P2 Rated motor power output. ● With single-phase motor = NMM - NMDM.
B-NM, B-NMD Bronze construction. H Total head in m. Maximum suction lift 1-2 m.
* Tolerances according to UNI EN ISO 9906:2012
Rated currents
P1 P2 230 V P2 230 V Δ / 400 V Y
1~ 400 V Δ / 690 V Y
kW kW HP IN A IA/IN kW HP IN A IN A IN A IA/IN
0,62 0,37 0,5 3 2,7 0,37 0,5 2,3 1,3 3,8
0,72 0,45 0,6 3,6 2,9 0,45 0,6 2,3 1,3 3,5
1 0,55 0,75 4,5 2,3 0,55 0,75 3 1,7 3,6
* NMM 25/12B/A 0,9 0,55 0,75 4,2 2,5 * NM 25/12B/A 0,55 0,75 2,8 1,6 3,9
* NMM 10/FE 0,9 0,55 0,75 4,2 2,5 * NM 10/FE 0,55 0,75 4 2,3 4,8
1,3 0,75 1 6 3 0,75 1 3,7 2,2 5,5
* NMM 25/12A/A 1,2 0,75 1 5,4 3,3 * NM 25/12A/B 0,75 1 3,5 2 6,1
* NMm 10/DE 1,2 0,75 1 5,8 2,6 * NM 10/DE 0,75 1 4 2,3 6,1
1,6 1,1 1,5 7,4 3 1,1 1,5 4,6 2,7 5,5
2 1,5 2 9,2 3,8 1,5 2 7,5 4,3 6,1
2,5 1,8 2,5 11,2 4,5 2,2 3 9,15 5,3 8,4
3 4 11,5 6,6 8,2
4 5,5 9,6 5,5 8,9
5,5 7,5 10,9 6,3 9,1
7,5 10 14,3 8,3 9,1
9,2 12,5 18,5 10,7 8,2
21
NM Close Coupled Centrifugal Pumps
with threaded ports
NM 1/A 90 NM 2 120
A Ø 158
25 35
80 40 42
43 100
A Ø 130 30 44
30 35 B Ø 143 η 45%
40 70
Hm
Hm
44
H ft
H ft
20 44 80
46
60
η 47%
20
50 60
15
40
40
10 10
0 3 1 2 3 4 5 0 3 1 2 3 4 5 6 7
0
Qm /h
l/min 20 30 40 50 60 70 80 0
m /h
Q l/min 50 100
0 l/s 0.2 0.4 0.6 0.8 1 1.2 0 l/s 0.5 1 1.5 1.9
0.6 1.0
A
0.5 0.7
1.0
P kW
P kW
P HP
P HP
B
0.4 0.5
0.5
0.5
0.3
0.3
0.2 0.0 0
5 8
15
4 6 20
NPSH m
NPSH m
NPSH ft
NPSH ft
3 10
4
2 10
5 2
1
0 0 0 0
0 Q m 3/h 1 2 3 4 72.047 5 0 Q m 3/h 1 2 3 4 5 6 72.048 7
H ft
Hm
Hm
η 38% 80
H ft
80
36 70
20
34 60
20 32
30 60 50
40
40 10
0 m /h 3 2 3 4 5 6 7 8 9
10 Q l/min
0 50 100 150
0 m3/h 1 2 3 4 5 1,6
Q
0 l/min 20 30 40 50 60 70 80 2
1,2 A 1,6
P kW
0,8 B 1,2
1.0
0,8
0,4
0,4
1.0
0 0
P kW
60
P HP
0.5
A
0.5 40
η (%)
20
0 0
4 0
8
NPSH m
NPSH m
3 10
NPSH ft
6 20
NPSH ft
2 4
5 10
1 2
0 0 0 0
0 Q m 3/h 1 2 3 4 72.050 5 0 Q m3/h 2 3 4 5 6 7 8 9
22
NM Close Coupled Centrifugal Pumps
with threaded ports
Hm
Hm
η 43% 100
H ft
H ft
40 30
C Ø 171 34
120
90
30 1~ 100 25
30 80
3~
80 43
70
20 20
0 3
0 2 3 4 5 6 7 8 9 Q m /h 1 2 3 4 5 6 7
3
Q m /h 0 l/min 20 40 60 80 100
0 l/min 50 100 150
0 l/s 0.5 1 1.5 2 2.4 0 l/s 0.4 0.6 0.8 1 1.2 1.4 1.6 1.8
2.6 1.2 1.6
A A
3 1.4
2 B 3~ 1.0
P kW
B 1.2
P kW
P HP
B 1~
P HP
2 0.8
C 3~ 1.0
1 C 1~
1 0.6 0.8
0.6
0 0 0.4
6 3
NPSH m
8
15
NPSH m
NPSH ft
NPSH ft
4 2
10
4
2 1
5
0 0 0 72.005
0
0 2 3 4 5 6 7 8 72.049/1 9 0 Q m3/h 1 2 3 4 5 6 7
Q m 3/h
Hm
55 100
H ft
H ft
20 64 30
66 62 60
60 90
15 η 70% 50 25
η 57% 80
56
40
70
10 20
3 0 3
0
Q m /h 2 4 6 8 10 12
Q m /h 2 4 6 8 10 12 14
0 l/min 50 100 150 200 0 l/min 50 100 150 200
P kW
0.6 0.8
P HP
P HP
1.0 1.4
0.4 0.6 1.2
0.4 0.8
1.0
0.2 0.6 0.8
0.2
0 0 0.4 0.6
6 5 16
NPSH m
NPSH m
15 4
12
NPSH ft
NPSH ft
4
3
10 8
2
2
5 1 4
0 72.006/N
0 0 72.007
0
0 Q m3/h 2 4 6 8 10 12 0 Q m3/h 2 4 6 8 10 12 14
23
NM Close Coupled Centrifugal Pumps
with threaded ports
65
Hm
Hm
B Ø 178 50
H ft
H ft
15
140
F Ø 103
40
40
120
10
30
30 100
0 3 5 10 15 20
Q m /h 5
0 l/min 50 100 150 200 250 300 3
0 5 10 15 20 25
4
S Q m /h
0 l/min 100 200 300 400
3 A 4
0 l/s 1 2 3 4 5 6
P kW
P HP
2 B
2 1.6
1 S 2.0
1.2 1.6
0 0 A
P kW
80
P HP
D 1.2
0.8
60
0.8
F
η (%)
40 0.4
0.4
20 0 0
0 8
10
30
NPSH m
8 6 20
NPSH ft
NPSH m
NPSH ft
6 20 4
4 10
B 10 2
2
S
0 0 0 72.052
0
0 Q m /h
3 5 10 15 72.008 0 Q m3/h 5 10 15 20 25
Hm
H ft
25 H ft
80 140
D Ø 178
40
20 120
60
15 30 100
0 3 5 10 15 3
0 5 10 15
Q m /h Q m /h
0 l/min 100 200 300 0 l/min 100 200 300
0 l/s 1 2 3 4 5 0 l/s 1 2 3 4 5
2.4 6
A 3~ 3 4 A
2.0 5
B 3~
P kW
P kW
A 1~ C
P HP
P HP
3 4
B 1~ 2
1.0 D 3
2
1 2
0.4 1
8 25 5
15
NPSH m
NPSH m
6 20 4
NPSH ft
NPSH ft
15 10
4
10 2
2 5
5
0 72.053
0 0 0
72.054
0 Q m3/h 5 10 15 0 Q m3/h 5 10 15
24
NMD Close Coupled Centrifugal Pumps
with threaded ports
Hm
Hm
38
H Ø 100 η 38,5% 100
H ft
H ft
10 30
30 38
37
20
5 20
10 50
0 0 10
0 0 3 1 2 3 4 5
Q m /h 10 20 30 40 50 60 70
3
Q m /h
0 l/min 200 400 600 800 1000 0 l/min 20 30 40 50 60 70 80
P HP
P HP
G Z
2 0.6 0.8
1 H B
0.6
1 0.4
0.4
0 0 0.2
5 4
15
NPSH m
NPSH m
4 3 10
NPSH ft
NPSH ft
3 10
2
2 5
5 1
1
0 0 0 0
72.057 72.001
0 Q m3/h 10 20 30 40 50 60 70 0 Q m3/h 1 2 3 4 5
Hm
H ft
H ft
50 B 1~ Ø 143-143 70
C Ø 156-164
150 60 200
40
35
40 50
40
30 100 30 100
3 3
0
Q m /h 1 2 3 4 5 6 0
Q m /h 2 4 6 8 10
0 l/min 20 40 60 80 100 0 l/min 50 100 150
0 l/s 0.2 0.4 0.6 0.8 1 1.2 1.4 1.6 0 l/s 0.5 1 1.5 2 2.5
2 5
A 3~ A
2.5 6
4
1.5 A 1~ B 5
2.0
P kW
P kW
P HP
P HP
B 3 4
1.5 C
1.0 3
2
1.0 2
0.6 1
4 5
15
NPSH m
NPSH m
3 10 4
NPSH ft
NPSH ft
3 10
2
5 2
1 5
1
0 72.003
0 0 0
72.009
0 Q m3/h 1 2 3 4 5 6 0 Q m3/h 2 4 6 8 10
25
NMD Close Coupled Centrifugal Pumps
with threaded ports
300 75 57.5
C Ø 194-172 η 45% C Ø 168-156 57
D Ø 176-176
Hm
Hm
80 D Ø 156-156 56
H ft
H ft
250 200
50
60 200
150
40 100
25
3 3
0 5 10 15 0 5 10 15 20
Q m /h Q m /h
0 l/min 50 100 150 200 250 300 0 l/min 100 200 300 400
0 l/s 1 2 3 4 5 0 l/s 1 2 3 4 5 6
10 10
12 12
A 8 A
8 10
B 10
P kW
P kW
6 B 8
P HP
P HP
C
6 C 8
4 6
D 6 D
4 4
2
4 2
2 0 0
6 5
15
NPSH m
NPSH m
15 4
NPSH ft
NPSH ft
4 10
3
10
2
2 5
5 1
0 0 0 0
72.013 72.029
0 Q m3/h 5 10 15 0 Q m3/h 5 10 15 20
26
NM Close Coupled Centrifugal Pumps
with threaded ports
NMM NM B-NM
TYPE
kg kg kg
NM 1/AE 8,7 8,6
NM 2/B/A 14 13,1
NM 2/S/A 14,2 13,3
NM 2/A/B 15,1 15
NM 6/B 17,8 17,6
NM 6/A 19,3 19
NM 3/C/A 24 22,9
NM 3/B/A 26 25,1
NM 3/A/B 30,4 29,1
B- NM 20/160BE 19,9 18,4 21
B- NM 20/160A/A 20,7 19,7 22,5
B- NM 25/12B/A 13,2 12,3 13,5
B- NM 25/12A/B 14,2 14,1 15,3
(NMM 3/A/A)
fM 131 (NMM 11/A) B- NM 25/160B/A 20,4 19,7 22,8
B- NM 25/160A/A 22,5 21,5 24
a l1 l2 NM 25/20B/C 31,6
DN2 DN2 NM 25/20A/B 40,9
NM 25/20S/C 42,2
B- NM 25/200B/C 35,7
B- NM 25/200A/C 43,7
B- NM 25/200S/C 45,2
h2 NM 10/FE 19,3 18,5
NM 10/DE 19,4 18,8
NM 10/A/A 20,2 19,3
DN1
DN1 DN2 mm
B-NM NM
ISO 228 a fM h1 h2 H m1 m2 n1 n2 n3 b s l1 l2 w g1
NM 1/AE G1 G1 40 261 80 132 176 40 32 170 140 17 35 9,5 77 81 171 10
NM 2/A/B-S/A-B/A G1 G1 45 305 95 150 207 40 32 190 160 17 35 9,5 87 90 203 10
NM 6/A-B G 11/4 G1 53 349 100 150 213 37,5 27,5 190 150 17 38 9,5 102 102 225 10
NM 3/ B/A-C/A 375 244
G1 G1 50 112 180 240 55 43 245 205 37 45 11,5 110 113 12
NM 3/A/B 415 284
B-NM 20/160A/A-BE NM 20/160A/A-BE G 11/4 G 3/4 53 375 100 150 228 37,5 27,5 190 150 30 38 9,5 102 102 246 10
B-NM 25/12A/B-B/A NM 25/12A/B-B/A G 11/2 G1 56 313 90 140 199 37,5 27,5 170 130 9 38 9,5 85 88 195 10
B-NM 25/160A/A-B/A NM 25/160A/A-B/A G 11/2 G1 56 380 100 160 228 37,5 27,5 190 150 30 38 9,5 102 102 246 10
NM 25/20B/C 433 253 49 291
G 11/2 G1 63 125 180 263 45 32,5 245 200 45 11,5 125 125 11
NM 25/20A/B-S/C 460 42 295
B-NM 25/200B/C 445 253 49 303
G 11/2 G1 63 125 180 263 45 32,5 245 200 45 11,5 125 125 11
B-NM 25/200A/B-S/C 460 42 295
NM 10/S/A-A/A-DE-FE G2 G 11/4 63 382 100 150 228 50 35 190 140 30 50 13 90 97 239 14
NM 11/ B/A 400 247
G2 G 11/4 70 112 170 240 50 35 210 160 37 50 15 103 110 14
NM 11/A/B 440 287
NM 12/D/B 440 260 47 287
G2 G 11/4 70 132 190 50 35 240 190 50 15 125 127 14
NM 12/A/B-C/A 470 270 45 300
B-NM 17/ G/A-H/A NM 17/ G/A-H/A 417 240 37 257
B-NM 17/F/B NM 17/F/B G 21/2 G 21/2 80 463 112 160 240 50 35 210 160 37 50 14 96 113 304 14
B-NM 17/D/A NM 17/D/A 480 250 20 295
27
NMD Close Coupled Centrifugal Pumps
with threaded ports
NMD 20/140
NMD 20/110 NMD 25/190
fM
a l1 l2
325
75 93 93 DN2 DN2
G1 G1
G 1 1/4
h2
132
204
DN1
H
10
95
h1
g1
4.93.179
4.93.005
36 9.5 17 38
46 130 m2 s n3 b
8.5 188 170
m1 n2
w n1
DN1 DN2 mm
B-NMD NMD
ISO 228 a fM h1 h2 H m1 m2 n1 n2 n3 b s l1 l2 w g1
B- NMD 20/140A/A-B/A NMD 20/140A/A-B/A G 11/4 G1 80 417 112 152 243 75 55 200 160 37 38 9,5 110 110 256 10
B- NMD 25/190C/B NMD 25/190C/B 487 268 50 314
G 11/2 G1 97 140 180 100 70 240 190 50 14 133 133 13
B- NMD 25/190A/B-B/B NMD 25/190A/B-B/A 500 278 49 306
NMD 32/210
NMD 40/180
fM
a l1 l2
DN2 DN2
DN1 DN2 mm
B-NMD NMD ISO 228 a fM h1 h2 H m4 m5 n4 n5 w1 b1 s1 l1 l2 w g2
B- NMD 32/210D/B NMD 32/210D/B 530 155 293 205 175 194 140
0 54 10 139 6*
B- NMD 32/210B/A -C/A NMD 32/210B/A -C/A G2 G 11/4 110 550 150 215 310 280 250 258 190
0 15 68 12 150 150 108 38
B- NMD 32/210A/B NMD 32/210A/B 625 170 355 298 268 286 216
6 70 12 152 38
B- NMD 40/180D/B NMD 40/180D/B 535 155 293 205 175 194 140
0 54 10 133 6*
B- NMD 40/180B/A -C/A NMD 40/180B/A -C/A G2 G 11/2 121 555 150 215 310 280 250 258 190
0 15 68 12 145 145 102 38
B- NMD 40/180A/B NMD 40/180A/B 630 170 355 298 268 286 216
6 70 12 145 38
28
NM Close Coupled Centrifugal Pumps
with threaded ports
Features
4.93.322
Compact Design
The compact design allows for easy installtion even in confined spaces.
Robust
The mechanical structure of the hydraulic parts in contact with the pumped liquid are
dimensioned to guarantee the maximum resistence to mechanical stress.
A unique design
The lantern bracket design prevents contact with the pumps rotating parts, providing
protection to the end user whilst allowing for inspection of the mechanical seal.
Reliable
The bearing and shaft are designed to ensure the reduction of the stress, providing
high reliability under all operating conditions.
29
NMD Close Coupled Centrifugal Pumps
with threaded ports
Features
3.94.044
Flexible
The option to choose between cast iron and bronze materias for the hydraulic
parts in contact with the pumped liquid allows NMD series pumps to be selected
for use with different types of liquids.
Robust
The mechanical structure of the hydraulic parts in contact with the pumped liquid
are dimensioned to guarantee the maximum resistence to mechanical stress.
Reliable
The bearing and shaft are designed to ensure the reduction of the stress, providing
high reliability under all operating conditions.
30
03/2021
Construction
Close-coupled centrifugal pumps; electric motor with extended
shaft directly connected to the pump up to 22 kW, new bracket
construction for standard motors (stub-shaft construction) from 30
to 75 kW with integrated thrust bearing.
Pump casing with axial suction and radial delivery on top, main
dimensions and performance according to EN 733.
NM(S): version with pump casing and lantern bracket in cast iron.
B-NM(S): version with pump casing and lantern bracket/casing
cover in bronze. (the pumps are supplied fully painted).
Connections: Flanges according to PN 10, EN 1092-2.
Counter-flanges (on request)
Sizes Flanges
from NM 32/.. to NM 50/... Screwed flanges EN 1092-1, PN 16
from NM 65/.. to NMS 100/... Flanges for welding EN 1092-1, PN 10
Version with frequency converter (on request)
Applications
For clean liquids without abrasives, which are non-aggressive for
the pump materials (solids content up to 0,2%). For water supply.
For heating, air conditioning, cooling and circulation plants.
For civil and industrial applications.
For irrigation.
Operating conditions
Liquid temperature from -10 °C to +90 °C.
Ambient temperature up to 40° C.
Total suction lift up to 7 m.
Maximum permissible working pressure up to 10 bar (16 bar for
NM 32L/16,20; NM 40/16,20; NM 50/12,16; NM 65/12,16,20,25; NM
The electropumps NM, B-NM, NMS, B-NMS series comply with the European 80/16,20,25; NM 100/20).
Regulation no. 547/2012. Continuous duty.
Materials Motor
Components NM, NMS B-NM, B-NMS 2-pole induction motor, 50 Hz (n ≈ 2900 rpm).
Pump casing NM, NMS: three-phase 230/400 V ± 10% up to 3 kW;
Lantern bracket NM Cast iron Bronze 400/690 V ± 10% from 4 to 75 kW.
Casing cover for NMS GJL 200 EN 1561 G-Cu Sn 10 EN 1982 Insulation class F. Protection IP 54 (IP 55 for NMS).
Motor suitable for operation with frequency converter from 1,1 kW.
Lantern bracket NMS Cast iron GJL 200 EN 1561 Classification scheme IE3 for three-phase motors from 0,75 kW.
Impeller Cast iron Bronze Constructed in accordance with: EN 60034-1; EN 60034-30-1.
GJL 200 EN 1561 G-Cu Sn 10 EN 1982
Brass P- Cu Zn 40 Pb 2 UNI 5705 Special features on request
for 32/12, 32/16, 32/20, 32L/20, 40/20 - Other voltages. - Frequency 60 Hz (as per 60 Hz data sheet).
Shaft Cr-Ni steel AISI 303 Cr Ni Mo steel - Protection IP 55.- Special mechanical seal.
AISI 430 from 3 kW to 22 kW AISI 316 - Packed gland (only for NM standard construction).
Mechanical seal Carbon - Ceramic - NBR
- Single-phase motor (NMM) up to 1,5 kW.
- Higher or lower liquid or ambient temperatures.
Counter-flanges Steel Fe 430B UNI 7070 - Motor suitable for operation with frequency converter up to 0,75 kW.
20
5
5 6 7 8 9 10 m 3/h 20 30 40 50 100 200 300 400 500
Q l/min
100 150 300 400 500 1000 2000 3000 4000 5000 8000
72 821 C
31
NM EI Close Coupled Centrifugal Pumps
with flanged connections
The NM EI pumps are available with power from 0,55 kW up to 37 kW, the pumps are equipped with I-MAT installed
on board which allows to realize a variable-speed system extremely compact and efficient, ideal in applications of water
supply and in the distribution of hot and cold water.
The pump is equipped with transducers suitable for operation and is already programmed at the factory.
Advantages
- Energy saving
- Compact design
- Easy to use
- Programmable to suit the system requirements
- Reliability
Costruction
The system comprises of:
- Pump
- Induction motor
- I-MAT Frequency converter
- Motor adapter for the motor mounting of the frequency converter
- Connection cable between frequency converter and induction motor
- Transducers
Main features
Rated motor power output from 0,55 kW to 37 kW
Control range from 1750 to 2900 rpm (2-pole)
Protection against dry running
Protection against operations with closed valve ports
Protection against system leakages
Protection against overcurrent in the motor
Protection agains overvoltage and undervoltage of the power supply
Protection against current unbalances between phases
Operating modes
H
Constant pressure mode
with pressure transducer +
-
In this mode, the system maintains the preset pressure when the flow required by
the installation changes.
Q
H
Proportional pressure mode
with pressure transducer +
-
In this mode the system changes the working pressure according to the required
flow rate.
H
Constant flow mode
with flow meter
-
+
In this mode the system maintains a constant flow rate value in a point of the instal-
lation according to the required pressure.
Q
H
Fixed speed mode
with setting of the speed preferential rotation. max
+
-
In this mode, by changing the working frequency, you may choose any operational
curve included within the working range. min
In this mode the system keeps the temperature constant inside a system by chan-
ging the speed of the pump.
32
NM, NMS Close Coupled Centrifugal Pumps
with flanged connections
Q
P2 m3/h 9,6 10,8 12 13,2 15 16,8 18,9 21 24 27 29 32 37,8 39
B-NM NM
kW HP l/min 160 180 200 220 250 280 315 350 400 450 483 533 630 650
B-NM 32L/16C NM 32L/16C 2,2 3 25,1 24,9 24,7 24,4 23,8 23 21,8 20,3 17,3 13,4
B-NM 32L/16B NM 32L/16B 3 4 30,4 30,3 30,2 30 29,6 29 28,1 26,8 24,2 20,8 17,9
B-NM 32L/16A NM 32L/16A 4 5,5 H 39,9 39,9 39,8 39,6 39,3 38,8 37,9 36,8 34,7 31,9 29,7 25,6
B-NM 32L/20C NM 32L/20C 4 5,5 m 42,1 41,8 41,5 41 40,2 38,9 37 34,5 29,7 23,8
B-NM 32L/200B NM 32L/20B 5,5 7,5 51,7 51,6 51,4 51,2 50,7 50 48,8 47 43,2 37,8 33,5
B-NM 32L/200A NM 32L/20A 7,5 10 59,4 59,4 59,4 59,4 59,2 58,8 58 56,6 53,4 48,6 44,6 37,7
Q
P2 m3/h 15 16,8 18,9 21 24 27 30 33 37,8 39 42 45 48 54
B-NM NM
kW HP l/min 250 280 315 350 400 450 500 550 630 650 700 750 800 900
B-NM 40/12F/A NM 40/12F/B 1,1 1,5 14 13,5 13 12 11 9,5 8 6
B-NM 40/12C/A NM 40/12C/B 1,5 2 17,5 17 16,5 16 15 13,5 12 10,5 7,5 6,5
B-NM 40/12A/B NM 40/12A/C 2,2 3 22 22 21,5 21 20 19 18 16,5 14 13 11,5
B-NM 40/16C/B NM 40/16C/C 2,2 3 23 22,5 22 21,5 20 18,5 16,5 14,5 11 10
B-NM 40/16B/A NM 40/16B/B 3 4 29 28,8 28 27,5 26,5 25 23,5 21,5 18 17 14
B-NM 40/16A/B NM 40/16A/C 4 5,5 37 36,5 36,5 36 35 33,5 32 30,5 27 26 23,5 20 17
H
B-NM 40/20D/B NM 40/20D/B 4 5,5 39 38 37 35,5 33,5 30,5 27 22,5 14
m
B-NM 40/20C/B NM 40/20C/B 4 5,5 41,5 40,5 39,5 38 36 33,5
B-NM 40/200B/A NM 40/20B/A 5,5 7,5 50 49,5 48,5 47,5 45,5 43,5 41,5 37,5 30,5
B-NM 40/200AR/A NM 40/20AR/A 5,5 7,5 55 54,5 54 53 51 49
B-NM 40/200A/A NM 40/20A/A 7,5 10 57,5 57 56,5 55,5 54,5 52,5 50,5 48 42,5 40,5 35
B-NM 4025/C/C NM 40/25C/C 9,2 12,5 61 61 60,5 59,5 58,5 56,5 53,5 49,5 41,5 40 33,5
B-NM 4025/B/C NM 40/25B/C 11 15 69,5 69,5 69 68,5 67 65,5 63,5 60,5 53,5 51 45
B-NM 4025/A/C NM 40/25A/C 15 20 90 90 89,5 89 88,5 87 85 83 77,5 76 70,5
Q
P2 m3/h 24 27 30 33 37,8 42 48 54 60 66 69 72 75 78 81 84
B-NM NM
kW HP l/min 400 450 500 550 630 700 800 900 1000 1100 1150 1200 1250 1300 1350 1400
B-NM 50/12F/B NM 50/12F/C 2,2 3 15,5 15 14 13,5 12 10 8 6
B-NM 50/12D/A NM 50/12D/B 3 4 20 19,5 18,5 18 16,5 14,5 13 10,5 9 8
B-NM 50/12A/B NM 50/12A/C 4 5,5 24 24 23 22,5 21 19,5 17,5 15 14 12,5 11,5 10
B-NM 50/12S/B NM 50/12S/C 4 5,5 26,5 26 25,5 24,5 23,5 22 20 18 16,5 15,5 14 13 11
B-NM 50/160B/B NM 50/16B/B 5,5 7,5 31 30,5 29,5 28 26 24 21,5 19 17,5 15,5 13,5 11,5 9,5
B-NM 50/160A/B NM 50/16A/B 7,5 10 38,5 38 37,5 36,5 34,5 32,5 30 27 25,5 24 22,5 20,5 19
B-NM 50/200B/C NM 50/20B/C 9,2 12,5 H 48 47,5 47,5 47 45,5 44,5 42,5 40 37 33 30,5 28 25,5 23
B-NM 50/200A/C NM 50/20A/C 11 15 m 55 55 54,5 54,5 53,5 52 50 48 45 41,5 39,5 37 35 32,5
B-NM 50/200S/C NM 50/20S/C 15 20 60 60 59,5 59,5 58,5 57,5 55,5 53,5 50,5 47 45 43 40,5 37
B-NM 5025/C/C NM 50/25C/C 11 15 55 54,5 54 53 51,5 49,5 46 41,5 35,5 28,5 24,5
B-NM 5025/B/C NM 50/25B/C 15 20 69 68,5 68 67,5 66 64 61 57 52,5 46,5 43
B-NM 50/25A NM 50/25A/D 18,5 25 80,5 80,5 80 79,5 78,5 77 74,5 71,5 67 61,5 58,5
B-NM 50/25S NM 50/25S 22 30 88,5 88,5 88 87 86 84 81,5 78,5 75 71 68,5
33
NM, NMS Close Coupled Centrifugal Pumps
with flanged connections
Q
P2 m3/h 75 84 96 108 120 132 150 168 180 192 210 240 270 300
B-NM - B-NMS NM - NMS
kW HP l/min 1250 1400 1600 1800 2000 2200 2500 2800 3000 3200 3500 4000 4500 5000
B-NM 80/160E/B NM 80/16E/B 7,5 10 21,5 20,9 19,9 18,7 17,4 15,9 13,4 10,6
B-NM 80/160D/C NM 80/16D/C 9,2 12,5 25,2 24,5 23,5 22,4 21,1 19,6 17,2 14,4
B-NM 80/160C/C NM 80/16C/C 11 15 28,7 28,2 27,4 26,4 25,1 23,8 21,3 18,5 16,4
B-NM 80/160B/C NM 80/16B/C 15 20 34,8 34,5 33,8 33 32,1 30,9 28,9 26,4 24,5 22,4
B-NM 80/16A NM 80/16A/D 18,5 25 39,9 39,6 39 38,2 37,4 36,4 34,5 32,2 30,3 28,1
B-NMS 80/200B/A NM 80/20B 22 30 46,5 46 45,5 44,5 43,5 42 39* 35,5* 32*
B-NMS 80/200A/A NMS 80/200A 30 40 56 55,5 55 54 53 52 49,5* 46* 43*
B-NMS 80/250E/A NM 80/25E 22 30 51 50 48,5 46,5 44,5 42 38* 33* 29*
B-NMS 80/250D/A NMS 80/250D 30 40 65 64 62,5 61 59 56,5 53* 49* 45,5* 41*
H
B-NMS 80/250C/A NMS 80/250C/A 37 50 m 73,5 73 72 70,5 69 67 63* 59* 55,5* 51,5*
B-NMS 80/250B/A NMS 80/250B/A 45 60 84 83,5 82,5 81,5 80 78 74,5* 70,5* 67* 63*
B-NMS 80/250A/A NMS 80/250A/A 55 75 95 94,5 93,5 92,5 91,5 90 87,5* 84* 80,5* 76,5*
B-NMS 100/200E/B NM 100/20E/A 18,5 25 30 29,5 29 28 27 26 25 23 19*
B-NMS 100/200D/A NM 100/20D 22 30 36 35,5 35 34 33 32 31 29 24,5* 19*
B-NMS 100/200C/A NMS 100/200C 30 40 45 44,5 44 43,5 42,5 41,5 40,5 39 34,5* 29* 22°
B-NMS 100/200B/A NMS 100/200B/A 37 50 54 53,5 53 52,5 51,5 50,5 49,5 48 44* 38,5* 32°
B-NMS 100/200A/A NMS 100/200A/A 45 60 61,5 61 60,5 60 59,5 58,5 58 56,5 53* 48* 42°
B-NMS 100/250B/A NMS 100/250B/A 55 75 73,5 73 72,5 71,5 70 68,5 67 65 61* 55,5* 48,5°
B-NMS 100/250A/A NMS 100/250A/A 75 100 91 90,5 90 89,5 88,5 88 87 85 81* 75* 67°
NM(S) Standard construction. P2 Rated motor power output. Maximum suction lift 1-2 m.
*
B-NM(S) Bronze construction. H Total head in m. ° With 1 m suction head.
Tolerances according to UNI EN ISO 9906:2012
Rated currents
P2 230V Δ / 400V Y
400V Δ / 690V Y
kW HP IN A IN A IN A IA/IN
0,55 0,75 4 2,3 4,8
0,75 1 4 2,3 6,1
1,1 1,5 4,6 2,7 5,5
1,5 2 7,5 4,3 6,1
2,2 3 9,2 5,3 8,4
3 4 11,5 6,6 8,2
4 5,5 9,6 5,5 8,9
5,5 7,5 10,8 6,2 9,1
7,5 10 14,3 8,3 9,1
9,2 12,5 18,5 10,7 8,2
11 15 21,5 12,4 8,5
15 20 27,3 15,8 9,5
18,5 25 34 19,6 9,5
22 30 41 23,7 9,5
30 40 53 30,5 8,6
37 50 65 37,5 7,1
45 60 78 45 6,9
P2 Rated motor power output.
55 75 95 55 6,7
IA/IN D.O.L. starting current / Nominal current
75 100 128 74 6,8
34
NM, NMS Close Coupled Centrifugal Pumps
with flanged connections
Hm
50
H ft
H ft
15
F Ø 103 25
80
40
10
30 20
60
20
5 15
0 3 5 10 15 20 25 0 3 5 10 15
Q m /h Q m /h
0 l/min 100 200 300 400 0 l/min 100 200 300
0 l/s 1 2 3 4 5 6 0 l/s 1 2 3 4 5
1.6 2.4
S 2.0 A 3
2.0
1.2 1.6
A B 3~
P kW
P kW
P HP
P HP
1.2 B 1~ 2
0.8 D
0.8
F 1.0
0.4
0.4 1
0 0 0.4
8 8 25
NPSH m
NPSH m
6 20 6 20
NPSH ft
NPSH ft
15
4 4
10 10
2 2 5
0 72.010
0 0 72.011
0
0 Q m3/h 5 10 15 20 25 0 Q m3/h 5 10 15
ft ft
Hm
HHmm
25 F Ø 112 80
HH
50
H ft
15
140 20
60
D Ø 178 40
40 15
10 40
120 10 30
5 20
0 m 3/h 10 20 30 20
30 100 50 Q
3
l/min 200 400
0 5 10 15 5 Q m /h 5
0 3 10 15 20 25 30 35
Q m /h
0 100 200 300 6
l/min 4 0 l/min 100 200 300 400 500 A
5
0 l/s 1 2 3 4 5 3 0 l/s 1 2 3 4 5 6 7 8 9 4
P kW
B
P HP
6 2.5
2 C 3
4 A 1 A 3.0
2
5 2.0 1
2.5
0 0
C 2.0
P kW
C 1.5
η (%) P kW
P HP
P HP
3 4 80
F 1.5
1.0
60
D 3
2 1.0
0.5 A
40 C B
2 0.5
1 200 0
5 04
15 10
30
NPSH m
NPSHmm
4 C B 10
83 A
NPSH ft
NPSHft ft
10
NPSH
6 20
NPSH
2
2 4 5
5 1 10
2
0 72.012
0 00 00
72.014
0 Q m3/h 5 10 15 00 Q3/h
Qm 5
m /h 3
10 15 20
20 25 3030 35
35
η
η
NM, NMS Close Coupled Centrifugal Pumps
with flanged connections
H ft
H ft
40
Hm
Hm
30 100
10 30
20 20
50 5
10 10
0 0 0 0
0 3 10 20 30 0 m 3/h 10 20 30 40 50
0
Qm /h
l/min 200 400 0
Q
l/min 200 400 600 800
8 2,5
10 A 3
A 2
6 8 C
B 1,5 2
P kW
P kW
P HP
6
P HP
4 C 1 F
4 1
2 0,5
2
0 0 0
0
80 80
60 A
60
C
η (%)
F
η (%)
40 40
C B A
η
20 20
0 0
6 5
A F A
4
NPSH m
NPSH m
NPSH ft
C
NPSH ft
4 3 10
10 2
B
2
1
0 0 0
0 0 Q m 3/h 10 20 30 40 50
0 Q m3/h 10 20 30
0 U.S. g.p.m. 50 100 150 200 0 U.S. g.p.m. 50 100 150 200
40 130 70
A Ø167 120
200
35 NM 40/16 110 60 A Ø 204
AR Ø 200 NM 40/20
B Ø 151 100 B Ø 195
30
90 50
80 C Ø 185
25 C Ø 137
70 40
D Ø 180
H ft
H ft
20
Hm
Hm
60 100
30
15 50
40
20
10 30
20
5 10
10
0 0 0 0
0 3 10 20 30 40 50 0 3 10 20 30 40 50
0
Q m /h 200 400 600 800 0
Q m /h 200 400 600 800
l/min l/min
5 10
A 6 12
4 5 8 AR A 10
3 B 4 6 B 8
P kW
P kW
P HP
P HP
2 C 3 4 D
6
2 4
1 1 2 C 2
0 0 0 0
80 80
AR
60 A 60
B B A
η (%)
η (%)
40 C 40 C
D
20 20
0 0
6 8 D A
A
NPSH m
NPSH m
C 6 20
NPSH ft
NPSH ft
4
10 4
2 10
2
0 0 0 0
0 Q m3/h 10 20 30 40 50 0 Q m3/h 10 20 30 40 50
36
η
η
NM, NMS Close Coupled Centrifugal Pumps
with flanged connections
H ft
50
H ft
Hm
50
150
Hm
40
40
10 30
30 100
20 20
50
10 10
0 0 0 0
0 m3/h 10 20 30 40 50 0 m3/h 20 30 40 50 60 70 80 90
Q Q l/min
0 l/min 200 400 600 800 0 500 1000 1500
16 5
A 20 S 6
4
12
B 16 A
D
P kW
3 4
P HP
C 12
P kW
8 F
P HP
8 2
4
2
4 1
0 0 0 0
60
A 80
B
40 C 60 S
η (%)
F D A
η (%)
40
20
20
0 0
6 8
NPSH m
6 20
NPSH m
NPSH ft
4 F S
NPSH ft
10 4
10
2 2
0 0 0 0
0 Q m3/h 10 20 30 40 50 0 Q m3/h 20 30 40 50 60 70 80 90
0 U.S. g.p.m. 100 150 200 250 300 350 0 U.S. g.p.m. 100 150 200 250 300 350
40 130 70
A Ø 174 120
S Ø 209
NM 50/16 110 60
A Ø 200 NM 50/20 200
B Ø 162 100
30 50 B Ø 188
90
150
80
40
H ft
H ft
70
20
Hm
Hm
60 100
30
50
40 20
10 30 50
20 10
10
0 0 0
0 0 20 30 40 50 60 70 80 90
0 m3/h 20 30 40 50 60 70 80 90 m3/h
Q l/min Q l/min
0 500 1000 1500 0 500 1000 1500
8 15 20
A 10
6
S
B 8 A 15
P kW
P kW
10
P HP
P HP
4 6 B
4 10
2 5
2
3 5
0 0
80 80
A 60 S
60 A
B
η (%)
η (%)
40 B
40
20 20
0 0
8
B
NPSH m
NPSH m
6 20 6 20
A
NPSH ft
NPSH ft
4 4
10 10
2 2
0 0 0 0
0 Q m3/h 20 30 40 50 60 70 80 90 0 Q m3/h 20 30 40 50 60 70 80 90
37
NM, NMS Close Coupled Centrifugal Pumps
with flanged connections
H ft
H ft
Hm
Hm
50
150 40
40 10 30
30 100 20
20 10
50
10 0 0
0 m3/h 20 30 40 50 60 70 80 0 m3/h 20 30 40 50 60 70 80 90 100 110 120 130
Q l/min Q l/min
0 500 1000 0 500 1000 1500 2000
8
S 30 A 10
20
A 6 8
C
P kW
B 20
6
P kW
P HP
4 E
P HP
10 C
10 4
2
2
0 0 0 0
80
80 A
60 C
A
A/S 60 E
B
η (%)
η (%)
40 C 40
20 20
0 0
10 8
30
NPSH m
8 20
NPSH m
6
A
NPSH ft
6 20 E
NPSH ft
4
4 10
10 2
2
0 0 0 0
0 Q m 3/h 20 30 40 50 60 70 80 0 Q m3/h 20 30 40 50 60 70 80 90 100 110 120 130
0 U.S. g.p.m. 100 200 300 400 500 600 0 U.S. g.p.m. 150 300 450 600
A Ø 175 60
40 A Ø 206 190
AR Ø 167
NM 65/16 130
NM 65/20 180
120
B Ø 193 170
B Ø 160 110 50 160
100 C Ø 182 150
30 C Ø 150
90 140
H ft
130
H ft
40
Hm
D Ø 143
Hm
80
120
70 110
20
60 100
30
90
50
80
40
70
10 20
0 m /h 20
3 30 40 50 60 70 80 90 100 110 120 130 140 0 3 30 60 90 120 150
Q l/min 0
Qm /h
l/min 500 1000 1500 2000 2500
0 500 1000 1500 2000
16 25
A 20 A 30
AR 20 25
12 16 B
B 20
P kW
15 C
P kW
C
P HP
8 12 15
D
P HP
10
8 10
4 5
4 5
0 0 0 0
100
A
80 AR
D 80 B
C B A
60 C
η (%)
η (%)
60
40
40
20
0 20
8 A
6 20
C
NPSH m
A
NPSH m
6 20
NPSH ft
D 4
NPSH ft
4 10
10 2
2
0 0 0 0
0 Q m3 /h 20 30 40 50 60 70 80 90 100 110 120 130 140 0 Q m3/h 30 60 90 120 150
38
NM, NMS Close Coupled Centrifugal Pumps
with flanged connections
H ft
C Ø 155 100
30
70 D Ø 147
220
H ft
25 E Ø 140 80
Hm
Hm
C Ø 212
200
60 20 60
180
15
50 160 40
10
140 20
40 5
0 3 20 30 40 50 60 70 80 90 100 110 120 130 140 0 3 50 100 150 200
Q m /h Q m /h
0 l/min 500 1000 1500 2000 20
0 l/min 1000 2000 3000
40 A
A 50 16
30 B B 20
40
12
P kW
P kW
C
P HP
20 C 30 D
8
P HP
20 E 12
10 4
10
0 0 0 0
80 A
C 80 A
60 B D C B
60 E
η (%)
η (%)
40
40
20
20
0
8 8
C
NPSH m
A
NPSH m
6 E A 20
NPSH ft
6 20
4
NPSH ft
4
10 10
2 2
0 0 0 0
0 Q m3 /h 20 30 40 50 60 70 80 90 100 110 120 130 140 0 Q m3/h 50 100 150 200
0 U.S. g.p.m. 200 400 600 800 0 U.S. g.p.m. 200 400 600 800
60 100
A Ø 264
A Ø 210 60 65 68
72 NM(S) 80/250
70
73
NM(S) 80/200 180
90 74
76
300
B Ø 250 η 77%
74
75 80 76
50 C Ø 238 250
160
B Ø 198
70
η 76%
Hm
Hm
D Ø 226
H ft
140 60 200 H ft
40 E Ø 207
50
120 150
40
68
30 100 30 100
0 3 50 100 150 200 3
0 50 100 150 200
Q m /h Q m /h
0 l/min 1000 2000 3000 0 l/min 1000 2000 3000
0 l/s 10 20 30 40 50 0 l/s 10 20 30 40 50
30 40 60 80
A
A
B 30 B 60
20 40
P kW
P kW
C
P HP
P HP
20 D 40
10 20 E
10 20
0 0 0 0
8 25
8 25
NPSH m
NPSH m
6 20
NPSH ft
NPSH ft
6 20
15
4 15
10 4
10
2 5 2 5
0 72.027
0 0 0
72.028
0 Q m3/h 50 100 150 200 0 Q m3/h 50 100 150 200
39
NM, NMS Close Coupled Centrifugal Pumps
with flanged connections
Hm
140
H ft
H ft
40 70
D Ø 180 74
120
60 200
E Ø 168
30 100
70
65 50
80
150
20
60 40
0 Q m3/h 50 100 150 200 250 300 0 Q m3/h 50 100 150 200 250 300
0 l/min 1000 2000 3000 4000 5000 0 l/min 1000 2000 3000 4000 5000
0 l/s 10 20 30 40 50 60 70 80 0 l/s 10 20 30 40 50 60 70 80
50 80
A A 100
60
40 B 60 B 80
C
P kW
P kW
30 40
P HP
P HP
60
40
20 D
E 40
20 20
10 20
0 0 0 0
10 10
30
NPSH m
NPSH m
8 26 8
NPSH ft
NPSH ft
6 20
6
16 4
4 10
2
2 72.033
6 0 72.034
0
0 Q m3/h 50 100 150 200 250 300 0 Q m3/h 50 100 150 200 250 300
40
NM, NMS Close Coupled Centrifugal Pumps
with flanged connections
1 2
DG
fM fM
a l1 l2 a l1 l2
DN2 DN2 DN2 DN2 W DN
A
DK
g2* 4.93.094 DE
DN1
h2 h2
mm
DN1
H H A
Holes
g1
h1 h1 DN DG DK DE N° Ø W
4.93.083.1
4.93.078.2 g2 32 76 100 140 4 19 18
m2 s n3 b m2 s s1 40 84 110 150 4 19 18
h4
m1 n2 m1 b b1 50 99 125 165 4 19 20
w m5 w1 n2 n5
w n1 65 118 145 185 4 19 20
m4 n1
80 132 160 200 8 19 22
100 156 180 220 8 19 24
125 184 210 250 8 19 24
mm
Picture NM kg
DN1 DN2 a fM h1 h2 H h4 m1 m2 n1 n2 n3 n5 w1 b b1 s s1 l1 l2 w m4 m5 g1 g2
NM 32/12DE-FE 24-24
50 32 80 405 112 140 240 - 100 70 190 140 37 - - 50 - 14 - 93 97 245 - - 12 -
NM 32/12S/A-A/A 27-26
NM 32/16B/A 410 250 34
50 32 80 132 160 260 - 100 70 240 190 47 - - 50 - 14 - 120 120 - - 12 -
NM 32/16A/B 450 290 39
NM 32/20D/B 450 288 62 290 42
50 32 80 160 180 - 100 70 240 190 - - 50 - 14 - 140 140 - 12 -
NM 32/20A/B-C/A 475 298 60 295 - 51-47
NM 32L/16C 450 260 47 290 38,6
50 32 80 132 160 - 100 70 240 190 - - 50 - 14 - 121 121 - - 10 -
NM 32L/16A-B 475 270 45 295 47,6-45,6
NM 32L/20C 475 298 60 295 52
50 32 80 160 180 - 100 70 240 190 - - 50 - 14 - 142 142 - - 12 -
NM 32L/20A-B 508 320 49 279 72-66
NM 40/12C/B-F/B 410 250 29-27
65 40 80 112 140 240 - 100 70 210 160 37 - - 50 - 14 - 100 113 - - 12 -
NM 40/12A/C 450 290 32
NM 40/16C/C 450 260 47 290 39
NM 40/16A/C-B/B 65 40 80 475 132 160 270 - 100 70 240 190 45 - - 50 - 14 - 121 122 295 - - 10 - 48-46
41
NM EI Close Coupled Centrifugal Pumps
with flanged connections
AG DG
AG
fM
AS
AS
fM l1 l2
l1 l2
W DN
a a DK
DN2 DN2
4.93.094 DE
A
g2* mm
H h2 h2
Holes
DN DG DK DE N° Ø W
DN1
DN1
H A
32 76 100 140 4 19 18
g1
h1 h1 40 84 110 150 4 19 18
4.93.083.1
4.93.078.2 g2 50 99 125 165 4 19 20
m2 s n3 b 65 118 145 185 4 19 20
m2 s s1
h4
m1 n2 m1 b b1 80 132 160 200 8 19 22
w m5 w1 n2 n5
w n1 100 156 180 220 8 19 24
m4 n1
125 184 210 250 8 19 24
mm
Picture NM EI kg
DN1 DN2 a fM AG AS h1 h2 H h4 m1 m2 n1 n2 n3 n5 w1 b b1 s s1 l1 l2 w m4 m5 g1 g2
NM EI 32/12DE-FE 30,4-30,4
50 32 80 435 190 105 112 140 398 - 100 70 190 140 37 - - 50 - 14 - 93 97 245 - - 12 -
NM EI 32/12S/A-A/A 32,4-33,4
NM EI 32/16B/A 440 190 105 250 40,4
50 32 80 132 160 418 - 100 70 240 190 47 - - 50 - 14 - 120 120 - - 12 -
NM EI 32/16A/B 470 210 118 290 46,5
NM EI 32/20D/B 470 446 62 290 49,5
50 32 80 210 118 160 180 - 100 70 240 190 - - 50 - 14 - 140 140 - - 12 -
NM EI 32/20A/B,C/A 485 454 60 295 59-54,5
NM EI 32L/16C 470 418 47 290 46,1
50 32 80 485 210 118 132 160 426 - 100 70 240 190 45 - - 50 - 14 - 121 121 295 - - 10 - 55,6-53,1
NM EI 32L/16A,B
NM EI 32L/20C 485 210 118 454 60 295 60
NM EI 32L/20B 50 32 80 508 281 153 160 180 482 - 100 70 240 190 49 - - 50 - 14 - 142 142 279 - - 12 - 74
NM EI 32L/20A 515 281 153 528 49 279 86,8
NM EI 40/12C/B-F/B 440 190 105 250 33,4-35,4
65 40 80 112 140 398 - 100 70 210 160 37 - - 50 - 14 - 100 113 - - 12 -
NM EI 40/12A/C 470 210 118 290 39,5
NM EI 40/16C/C 470 418 47 290 46,5
1 65 40 80 210 118 132 160 - 100 70 240 190 - - 50 - 14 - 121 122 - - 10 -
NM EI 40/16A/C,B/B 485 426 45 295 56-53,5
NM EI 40/20C/B-D/B 505 210 118 454 60 295 61-62
NM EI 40/20AR/A-B/A 65 40 100 528 281 153 160 180 482 - 100 70 265 212 49 - - 50 - 14 - 142 142 279 - - 12 - 75-75
NM EI 40/20A/A 535 281 153 528 49 279 87,8
NM EI 40/25C/C 640 281 153 573 400 122,8
NM EI 40/25B/C 65 40 100 690 281 153 180 225 573 - 125 95 320 250 50 - - 65 - 14 - 175 175 460 - - 15 - 131,8
NM EI 40/25A/C 738 350 190 651 460 166,8
NM EI 50/12F/C 490 418 47 290 47,5
65 50 100 210 118 132 160 426 - 100 70 240 190 - - 50 - 14 - 122 137 - - 10 -
NM EI 50/12S/C-A/C-D/B 505 45 295 57-57-54,5
NM EI 50/16B/B 528 482 72
65 50 100 160 180 - 100 70 265 212 49 - - 50 - 14 - 126 140 279 - - 12 -
NM EI 50/16A/B 535 281 153 528 85,3
NM EI 50/20B/C 640 281 153 553 400 114,8
NM EI 50/20A/C 65 50 100 690 281 153 160 200 553 - 100 70 265 212 40 - - 50 - 14 - 140 153 460 - - 15 - 123,8
NM EI 50/20S/C 738 350 190 631 460 166
NM EI 50/25C/C 695 281 153 533 465 136,8
65 50 100 180 225 - 125 95 320 250 50 - - 65 - 14 - 175 175 - - 15 -
NM EI 50/25B/C 743 350 190 651 465 180
2 NM EI 50/25S-A/D 65 50 100 769 350 190 180 225 671 - 125 95 320 250 - 254 20 65 60 14 15 175 175 166 394 354 15 20* -
NM EI 65/12E/C 510 210 118 482 60 300 59,9
NM EI 65/12C/B 80 65 100 533 281 153 160 180 528 - 125 95 280 212 49 - - 65 - 14 - 130 154 284 - - 12 - 72,7
NM EI 65/12A/B 540 281 153 528 49 284 85,5
NM EI 65/16D/B 528 281 153 582 49 279 85,3
NM EI 65/16C/C 153 160 200 553 107,8
80 65 100 640 281 - 125 95 280 212 40 - - 65 - 14 - 140 161 410 - - 12 -
NM EI 65/16B/C 690 281 153 553 40 410 126,8
NM EI 65/16A/C-AR 738 350 190 631 40 460 162
NM EI 65/20C/C 80 65 100 738 350 190 180 225 651 - 125 95 320 250 50 - - 65 - 14 - 159 179 460 - - 12 - 171
NM EI 65/20A/A-B/D 80 65 100 765 350 190 180 225 671 - 125 95 320 250 - 254 20 80 60 14 15 155 175 175 394 354 - 20* - -
2
NM EI 65/25C/A 80 65 100 765 350 190 202 250 693 2 160 120 360 280 - 254 20 80 90 18 14 179 185 182 400 360 - 42* 222
NM EI 80/16E/B 555 281 153 548 60 279 92,3
NM EI 80/16D/C 670 281 153 573 50 415 115,8
100 80 125 180 225 - 125 95 320 250 - - 65 - 14 - 165 193 - - 15 -
1 NM EI 80/16C/C 720 350 190 573 50 465 134,8
NM EI 80/16B/C 768 350 190 651 50 465 167
NM EI 80/16A/D 100 80 125 792 350 190 180 225 671 - 125 95 345 280 - 254 20 80 60 18 15 170 194 164 394 354 - 20* -
NM EI 80/20B 100 80 125 790 350 190 202 250 693 22 125 95 345 280 - 254 20 80 90 18 14 170 194 182 400 360 - 42* 215
2
NM EI 80/25E 100 80 125 790 350 190 202 280 693 2 160 120 400 315 - 254 20 80 90 18 14 191 210 182 400 360 - 42* 228
NM EI 100/20D-E/A 125 100 125 790 350 190 200 280 691 - 160 120 360 280 - 254 20 80 60 18 15 180 212 162 394 354 - 40* - -
42
NM, NMS Close Coupled Centrifugal Pumps
with flanged connections
1 1°
fM
a l1 l2
DN2 DN2
Flanges EN 1092-2
DN1
h2
H
A h1 DG
h1
HA
A n
m2
4.93.466.1
s K n1 2 2
m 1 W DN
m1 b AA m
w B n2 A DK
BB n1 DE
4.93.094
2 2° mm
Holes
fM
a l1 l2 DN DG DK DE N° Ø W
DN2 DN2 32 76 100 140 4 19 18
40 84 110 150 4 19 18
50 99 125 165 4 19 20
DN1
mm
Picture NMS kg
DN1 DN2 a fM h1 h2 H m1 m2 n1 n2 A n5 w1 b AA b1 s K s1 l1 l2 w BB m4 B m5 HA g2
2 NMS 65/250B/A 80 65 100 961 200 250 486 160 120 360 280 - 279 20 80 - 70 18 - 15 179 195 333 - 440 - 400 - 20 236
1 NMS 65/250A/B 80 65 100 1009 200 250 515 160 120 360 280 318 - - 80 70 - 18 19 - 200 200 406 355 - 305 - 25 - 298
1 NMS 80/200A 100 80 125 986 180 250 466 125 95 345 280 279 - - 65 65 - 14 19 - 170 194 394 328 - 279 - 20 - 222
2 NMS 80/250D 100 80 125 986 200 280 486 160 120 400 315 - 279 20 80 - 70 18 - 15 191 211 333 - 440 - 400 - 20 242
1 NMS 80/250C/A 100 80 125 1034 200 280 515 160 120 400 315 318 - - 80 70 - 18 19 - 200 210 406 355 - 305 - 25 - 300
1° NMS 80/250B/A 100 80 125 1129 225 280 563 298 258 410 315 356 - - - 80 - 18 19 - 225 225 445 361 - 311 - 34 - 437
2° NMS 80/250A/A 100 80 125 1198 280 280 690 260 220 410 315 - 406 25 - - 100 18 - 24 275 275 443 - 500 - 450 - 8 534
2 NMS 100/200C 125 100 125 986 200 280 486 160 120 360 280 - 279 20 80 - 70 18 - 15 180 212 333 - 440 - 400 - 20 236
1 NMS 100/200B/A 125 100 125 1034 200 280 515 160 120 360 280 318 - - 80 70 - 18 19 - 200 212 406 355 - 305 - 25 - 338
1° NMS 100/200A/A 125 100 125 1129 225 280 563 298 258 410 315 356 - - - 80 - 18 19 - 225 225 445 361 - 311 - 34 - 426
2° NMS 100/250B/A 125 100 140 1213 280 280 690 260 220 410 315 - 440 25 - - 100 18 - 24 275 275 443 - 500 - 450 - 8 545
1° NMS 100/250A/A 125 100 140 1286 280 280 713 260 220 410 315 457 - - - 100 - 18 24 - 275 275 516 479 - 368 - 40 - 648
43
NMS EI Close Coupled Centrifugal Pumps
with flanged connections
1
AG
AS
fM l1 l2
Flanges EN 1092-2
a
DN2
DG
DN1
h2
H W DN
A
h1
DK
HA 4.93.094 DE
A 4.93.466.1.EI
m2 s K
m1 b AA mm
w B n2 A
BB n1 Holes
DN DG DK DE N° Ø W
32 76 100 140 4 19 18
2 40 84 110 150 4 19 18
50 99 125 165 4 19 20
AG
65 118 145 185 4 19 20
fM AS
l1 l2
80 132 160 200 8 19 22
100 156 180 220 8 19 24
125 184 210 250 8 19 24
a
DN2
DN1
h2
H A
h1
g2
A 4.93.466.1.EI
m2 s s1
m1 b b1
w m5 w1 n2 n5
m4 n1
mm
Picture
NMS EI kg
DN1DN2 a fM AG AS h1 h2 H m1 m2 n1 n2 A n5 w1 b AA b1 s K s1 l1 l2 w BB m4 B m5 HA g2
2 NMS EI 65/250B/A 80 65 100 961 350 190 200 250 486 160 120 360 280 - 279 20 80 - 70 18 - 15 179 195 333 - 440 - 400 - 20 271
1 NMS EI 65/250A/B 80 65 100 1009 350 190 200 250 515 160 120 360 280 318 - - 80 70 - 18 19 - 200 200 406 355 - 305 - 25 - 333
2 NMS EI 80/250D 100 80 125 986 350 190 200 280 486 160 120 400 315 - 279 20 80 - 70 18 - 15 191 211 333 - 440 - 400 - 20 277
1 NMS EI 80/250C/A 100 80 125 1034 350 190 200 280 515 160 120 400 315 318 - - 80 70 - 18 19 - 200 210 406 355 - 305 - 25 - 335
2 NMS EI 100/200C 125 100 125 986 350 190 200 280 486 160 120 360 280 - 279 20 80 - 70 18 - 15 180 212 333 - 440 - 400 - 20 271
1 NMS EI 100/200B/A 125 100 125 1034 350 190 200 280 515 160 120 360 280 318 - - 80 70 - 18 19 - 200 212 406 355 - 305 - 25 - 373
44
B-NM, B-NMS Close Coupled Centrifugal Pumps
with flanged connections
1 2
DG
fM fM
a l1 l2 a l1 l2
DN2 DN2 W DN
DN2 DN2
A
DK
g2* 4.93.094 DE
DN1
h2
h2
mm
DN1
H H A
Holes
g1
h1 h1 DN DG DK DE N° Ø W
4.93.083.1
4.93.078.1 g2 32 76 100 140 4 19 18
m2 s n3 b 40 84 110 150 4 19 18
m2 s s1
h4
m1 n2 m1 b b1 50 99 125 165 4 19 20
w m5 w1 n2 n5
w n1 65 118 145 185 4 19 20
m4 n1
80 132 160 200 8 19 22
100 156 180 220 8 19 24
125 184 210 250 8 19 24
mm kg
Picture
B- NM
DN1 DN2 a fM h1 h2 H h4 m1 m2 n1 n2 n3 n5 w1 b b1 s s1 l1 l2 w m4 m5 g1 g2 B-NM
B-NM 32/12D-F 27-27
50 32 80 405 112 140 240 - 100 70 190 140 37 - - 50 - 14 - 93 97 245 - - 12 - 30-28
B-NM 32/12S/A-A/A
B-NM 32/16B/A 410 250 38,5
50 32 80 132 160 260 - 100 70 240 190 47 - - 50 - 14 - 120 120 - - 12 -
B-NM 32/16A/B 450 290 42
1 B-NM 32/20D/B 450 288 45 290 47,5
50 32 80 160 180 - 100 70 240 190 - - 50 - 14 - 140 140 - - 12 -
B-NM 32/20A/B-C/A 475 298 60 295 58-56,5
B-NM 32L/16C 450 260 47 290 42,5
50 32 80 132 160 - 100 70 240 190 - - 50 - 14 - 121 121 - - 10 -
B-NM 32L/16A-B 475 270 45 295 52,5-49,5
B-NM 32L/20C 475 298 60 295 58,3
50 32 80 160 180 - 100 70 240 190 - - 50 - 14 - 142 142 - - 12 -
1* B-NM 32L/200A-B 563 320 49 334 79,3-73,8
B-NM 40/12C/A-F/A 410 250 33-31
65 40 80 112 140 240 - 100 70 210 160 37 - - 50 - 14 - 100 113 - - 12 -
B-NM 40/12A/B 450 290 36
1 B-NM 40/16C/B 450 260 47 290 43
65 40 80 132 160 - 100 70 240 190 - - 50 - 14 - 121 122 - - 10 -
B-NM 40/16A/B-B/A 475 270 45 295 53-50
B-NM 40/20C/B-D/B 495 298 60 295 59,5-59
65 40 100 160 180 - 100 70 265 212 - - 50 - 14 - 142 142 - - 12 -
1* B-NM 40/200A/A-AR/A-B/A 583 320 49 334 80,5-75
B-NM 4025/C/C 635 124
2 B-NM 4025/B/C 65 40 100 685 192 225 377 12 125 95 320 250 - 216 20 65 69 14 12 175 175 174 298 258 - 6 130
B-NM 4025/A/C 710 159,5
B-NM 50/12F/B 470 260 47 290 44
65 50 100 132 160 - 100 70 240 190 - - 50 - 14 - 122 137 - - 10 -
1 B-NM 50/12S/B-A/B-D/A 495 270 45 295 54,5-54-52
1* B-NM 50/160A/B-B/B 65 50 100 583 160 180 320 - 100 70 265 212 49 - - 50 - 14 - 126 140 334 - - 12 - 80-74,5
B-NM 50/200B/C 695 123
B-NM 50/200A/C 65 50 100 745 192 200 377 32 100 70 265 212 - 216 20 50 69 14 12 140 153 234 298 258 - 6 132
B-NM 50/200S/C 769 154
2 B-NM 5025/C/C 685 135
65 50 100 192 225 377 12 125 95 320 250 - 216 20 65 69 14 12 175 175 174 298 258 - 6
B-NM 5025/B/C 710 156
B-NM 50/25S-A 65 50 100 766 180 225 386 - 125 95 320 250 - 254 20 65 60 14 15 175 175 166 394 354 - 20* -
1 B-NM 65/12E/A 80 65 100 500 160 180 298 - 125 95 280 212 60 - - 65 - 14 - 130 154 300 - - 12 - 57,3
B-NM 65/125A/B-C/B 80 65 100 588 160 180 320 - 125 95 280 212 49 - - 65 - 14 - 130 154 339 - - 12 - 80,5-74,5
1* B-NM 65/160D/B 583 320 49 334 80,2
80 65 100 160 200 - 125 95 280 212 - - 65 - 14 - 140 179 - - 12 -
B-NM 65/160C/C 660 345 40 430 101
B-NM 65/160B/C 745 140
80 65 100 192 200 377 32 125 95 280 212 - 216 20 65 69 14 12 140 179 234 298 258 - 6
B-NM 65/160A/C-AR 770 152
2 B-NM 65/200C/C 80 65 100 775 192 225 377 12 125 95 320 250 - 216 20 65 69 14 12 159 179 239 298 258 - 6 160
B-NM 65/250C/B 80 65 100 825 202 250 408 2 160 120 360 280 - 254 20 80 90 18 14 179 195 245 400 360 - 42* 210
B-NM 80/160E/B 608 340 60 334 89,4
1* 100 80 125 180 225 - 125 95 320 250 - - 65 - 14 - 153 181 - - 12 -
B-NM 80/160D/C 685 365 50 430 109
B-NM 80/160C/C 775 149
100 80 125 192 225 377 12 125 95 320 250 - 216 20 65 69 14 12 153 181 239 298 258 - 6
2 B-NM 80/160B/C 800 161
B-NM 80/16A 100 80 125 789 180 225 386 - 125 95 320 250 - 254 20 65 60 14 15 153 181 164 394 354 - 20* -
Flanges EN 1092-2
DN1
h2
H
A h1
h1
HA
DG
A n
m2
4.93.466.1
s K n1 2 2
m 1
m1 b AA m
w B n2 A W DN
BB n1
DK
4.93.094 DE
2 2°
mm
fM
a l1 l2 Holes
DN2 DN2
DN DG DK DE N° Ø W
32 76 100 140 4 19 18
40 84 110 150 4 19 18
DN1
h2
50 99 125 165 4 19 20
H A h1 65 118 145 185 4 19 20
h1 80 132 160 200 8 19 22
g2 n 100 156 180 220 8 19 24
4.93.466.1 n1 2 2
A m 1 125 184 210 250 8 19 24
m2 s s1 m
m1 b b1
w m5 w1 n2 n5
m4 n1
mm
Picture B-NMS kg
DN1 DN2 a fM h1 h2 H m1 m2 n1 n2 A n5 w1 b AA b1 s K s1 l1 l2 w BB m4 B m5 HA g2
2 B-NMS 65/200A-B 80 65 100 864 180 225 386 125 95 320 350 - 254 20 65 - 60 14 -
15 159 179 331 - 394 - 354 - 20
2 B-NMS 65/250B/A 80 65 100 961 200 250 486 160 120 360 280 - 279 20 80 - 70 18 -
15 179 195 333 - 440 - 400 - 20
1 B-NMS 65/250A/B 80 65 100 1009 200 250 515 160 120 360 280 318 - - 80 70 - 18 19 - 200 200 406 355 - 305 - 25 - 308
2 B-NMS 80/200B/A 100 80 125 936 180 250 387 125 95 345 280 - 254 20 65 - 60 14 - 15 175 194 331 - 350 - 310 - 5
1 B-NMS 80/200A/A 100 80 125 986 180 250 466 125 95 345 280 279 - - 65 65 - 14 15 - 170 194 394 328 - 279 - 20 - 231
2 B-NMS 80/250E/A 100 80 125 936 200 280 407 160 120 400 315 - 254 20 80 - 60 18 - 15 191 210 331 - 394 - 354 - 6
2 B-NMS 80/250D/A 100 80 125 986 200 280 486 160 120 400 315 - 279 20 80 - 70 18 - 15 191 212 333 - 440 - 400 - 20 287
1 B-NMS 80/250C/A 100 80 125 1034 200 280 515 160 120 400 315 318 - - 80 70 - 18 19 - 200 210 406 355 - 305 - 25 -
1° B-NMS 80/250B/A 100 80 125 1129 225 280 563 298 258 410 315 356 - - - 80 - 18 19 - 225 225 445 361 - 311 - 34 -
2° B-NMS 80/250A/A 100 80 125 1198 280 280 690 260 220 410 315 - 406 25 - - 100 18 - 24 275 275 443 - 500 - 450 - 8
2 B-NMS 100/200D/A-E/B 125 100 125 936 200 280 407 160 120 360 280 - 254 20 80 - 60 18 - 15 180 212 331 - 394 - 354 - 6
2 B-NMS 100/200C/A 125 100 125 986 200 280 486 160 120 360 280 - 279 20 80 - 70 18 -
15 180 212 333 - 440 - 400 - 20
1 B-NMS 100/200B/A 125 100 125 1034 200 280 515 160 120 360 280 318 - - 80 70 - 18 19
- 200 212 406 355 - 305 - 25 - 352
1° B-NMS 100/200A/A 125 100 125 1129 225 280 563 298 258 410 315 356 - - - 80 - 18 19
- 225 225 445 361 - 311 - 34 -
2° B-NMS 100/250B/A 125 100 140 1213 280 280 690 260 220 410 315 - 440 25 - - 100 18 - 24 275 275 443 - 500 - 450 - 8
1° B-NMS 100/250A/A 125 100 140 1286 280 280 713 260 220 410 315 457 - - - 100 - 18 24 - 275 275 516 479 - 368 - 40 -
46
NM, NMS Close Coupled Centrifugal Pumps
with flanged connections
Features
NM
Flexible
The option to choose between cast iron and bronze materias for the hydraulic parts
in contact with the pumped liquid allows NM series pumps to be selected for use with
different types of liquids.
Compact Design
The compact design allows for easy installtion even in confined spaces.
Exclusive design
An innovative, patented guard prevents contact with rotating parts, proving protection
to the end user whilst allowing for inspection of the mechanical seal.
Reliable
The bearing and shaft are designed to ensure the reduction of the stress, providing
high reliability under all operating conditions.
47
NM, NMS Close Coupled Centrifugal Pumps
with flanged connections
Features
NMS
Flexible
The option to choose between cast iron and bronze materias for the hydraulic parts in
contact with the pumped liquid allows NMS series pumps to be selected for use with dif-
ferent types of liquids.
Exclusive design
An innovative, patented guard prevents contact with rotating parts, proving protection to
the end user whilst allowing for inspection of the mechanical seal.
48
03/2021
Construction
Close-coupled centrifugal pumps; electric motor with extended
shaft directly connected to the pump up to 15 kW, new bracket
construction for standard motors (Stub-shaft construction) from
18,5 to 75 kW with integrated thrust bearing. Pump casing with axial
suction and radial delivery on top, main dimensions and perfor-
mance according to EN 733 with additional sizes for completion.
NM(S)4: version with pump casing and lantern bracket in cast iron.
B-NM(S)4: version with pump casing and lantern bracket/casing
cover in bronze. (the pumps are supplied fully painted).
Connections
Sizes Connections
NM4 25/... Threaded ports ISO 228
from NM4 32/.. to NMS4 150/.. Flanges according to PN 10, EN 1092-2
Counter-flanges (on request)
Sizes Flanges
from NM4 32/.. to NM4 50/.. Screwed flanges EN 1092-1, PN 16
from NM4 32/.. to NMS4 150/.. Flanges for welding EN 1092-1, PN 10
Version with frequency converter (on request)
Applications
For clean liquids without abrasives, which are non-aggressive
for the pump materials (contents of solids up to 0,2%).
For water supply. For heating, air conditioning, cooling and
circulation plants. For civil and industrial applications.
When low noise operating is required. For irrigation.
Operating conditions
Liquid temperature from -10 °C to +90 °C.
The electropumps NM4, B-NM4, NMS4, B-NMS4 series comply with the European Ambient temperature up to 40 °C.
Regulation no. 547/2012. Total suction lift up to 7 m.
Maximum permissible working pressure up to 10 bar (16 bar for NM4 40/16,20;
Materiali NM4 50/16; NM4 65/16,20,25; NM(S)4 80/16,20,25,31,400; NM4 100/20).
Continuous duty.
Components NM4, NMS4 B-NM4, B-NMS4
Pump casing
Motor
Cast iron Bronze 4-pole induction motor, 50 Hz (n ≈ 1450 rpm).
Lantern bracket NM4
GJL 200 EN 1561 G-Cu Sn 10 EN 1982 NM4, NMS4: three-phase 230/400 V ± 10% up to 3 kW;
Casing cover for NMS4 400/690 V ± 10% from 4 to 75 kW.
Lantern bracket NMS4 Cast iron GJL 200 EN 1561 Insulation class F. Protection IP 54 (IP 55 for NMS4).
Impeller Cast iron GJL 200 EN 1561 Bronze G-Cu Sn 10 EN 1982 Motor suitable for operation with frequency converter from 0,75 kW.
Brass P- Cu Zn 40 Pb 2 UNI 5705 Classification scheme IE3 for three-phase motors from 0,75 kW.
For NM4 25/125 - 25/160 - 25/200 - NM4 32/16 - 32/20 - 40/20 Constructed in accordance with: EN 60034-1; EN 60034-30-1.
Shaft Cr-Ni steel AISI 303 Cr Ni Mo steel Special features on request
AISI 430 from 1,5 kW to 15 kW AISI 316 - Other voltages. - Frequency 60 Hz (as per 60 Hz data sheet).
Mechanical seal Carbon - Ceramic - NBR - Protection IP 55. - Special mechanical seal.
- Higher or lower liquid or ambient temperatures.
Counter-flanges Steel Fe 430B UNI 7070
- Motor suitable for operation with frequency converter up to 0,55 kW.
3 10
7
2
2 m 3/h 5 10 20 30 40 50 100 200 300 400 500 700
40 50
Q l/min 100 150 200 300 400 500 1000 5000 10000
72 849 C
49
NM4 EI Close Coupled Centrifugal Pumps
with flanged connections
The NM4 EI pumps are available with power from 0,25 kW up to 30 kW, the pumps are equipped with I-MAT
installed on board which allows to realize a variable-speed system extremely compact and efficient, ideal in
applications of water supply and in the distribution of hot and cold water.
The pump is equipped with transducers suitable for operation and is already programmed at the factory.
Advantages
- Energy saving
- Compact design
- Easy to use
- Programmable to suit the system requirements
- Reliability
Costruction
The system comprises of:
- Pump
- Induction motor
- I-MAT Frequency converter
- Motor adapter for the motor mounting of the frequency converter
- Connection cable between frequency converter and induction motor
- Transducers
Main features
Rated motor power output from 0,25 kW to 30 kW
Control range from 870 to 1450 rpm (4-pole)
Protection against dry running
Protection against operations with closed valve ports
Protection against system leakages
Protection against overcurrent in the motor
Protection agains overvoltage and undervoltage of the power supply
Protection against current unbalances between phases
Operating modes
H
Constant pressure mode
with pressure transducer +
-
In this mode, the system maintains the preset pressure when the flow required by
the installation changes.
Q
H
Proportional pressure mode
with pressure transducer +
-
In this mode the system changes the working pressure according to the required
flow rate.
H
Constant flow mode
with flow meter
-
+
In this mode the system maintains a constant flow rate value in a point of the instal-
lation according to the required pressure.
Q
H
Fixed speed mode
with setting of the speed preferential rotation. max
+
-
In this mode, by changing the working frequency, you may choose any operational
curve included within the working range. min
In this mode the system keeps the temperature constant inside a system by chan-
ging the speed of the pump.
50
NM4, NMS4 Close Coupled Centrifugal Pumps
Q
P2 1 1,2 1,5 1,89 2,4 3 3,6 4,2 4,8 5,4 6 6,6 7,5 8,4 9,6 10,8 12 13,2 15
B - NM4 m3/h
NM4
kW HP l/min 16 20 25 31,5 40 50 60 70 80 90 100 110 125 140 160 180 200 220 250
NM4 25/12A/A 0,25 0,34 6,1 6,05 6 5,9 5,8 5,5 5,2 4,8 4,4 3,9 3,3
B- NM4 25/160BE NM4 25/160BE 0,37 0,5 7,7 7,65 7,6 7,55 7,5 7,2 6,9 6,6 6,1 5,5 4,6 3,6
B- NM4 25/160AE NM4 25/160AE 0,37 0,5 H 9,2 9,15 9,1 9,05 9 8,7 8,5 8,2 7,8 7,2 6,5 5,6 3,7
B- NM4 25/200C/A NM4 25/200C/A 0,37 0,5 m 11,5 11,4 11,4 11,3 11,2 11,1 10,9 10,7 10,5 10,2 9,8 9,4 8,6 7,7 6 3,6
B- NM4 25/200B/A NM4 25/200B/A 0,55 0,75 13,2 13,2 13,2 13,1 13,1 13 12,9 12,7 12,5 12,3 11,9 11,5 11,0 10,3 8,9 6,9 4,1
B- NM4 25/200A/C NM4 25/200A/C 0,75 1 14,5 14,5 14,5 14,5 14,5 14,4 14,3 14,2 14 13,8 13,5 13,2 12,7 12,1 11 9,2 6,8 2,9
Q
P2 2,4 3 3,6 4,8 5,4 6 7,5 8,4 9,6 10,8 12 13,2 15 16,8 18,9 21 24 27 30
B - NM4 m3/h
NM4
kW HP l/min 40 50 60 80 90 100 125 140 160 180 200 220 250 280 315 350 400 450 500
B-NM4 32/16B NM4 32/16BE 0,37 0,5 7,6 7,5 7,4 7,2 7,1 6,9 6,3 5,9 5,2 4,2
B-NM4 32/16A NM4 32/16AE 0,37 0,5 9 8,95 8,9 8,7 8,6 8,5 7,9 7,5 6,8 6 5,1
B-NM4 32/20B NM4 32/20BE 0,55 0,75
5 12,5 12,4 12,3 12 11,8 11,6 10,6 10 8,9 7,6 6,2 4,7
B-NM4 32/20A/B NM4 32/20A/B 0,75 1 14,3 14,2 14,1 13,9 13,7 13,5 12,9 12,3 11,3 10,2 8,9 7,5
B-NM4 40/16C NM4 40/16C/A 0,37 0,5 6,1 6 5,9 5,8 5,6 5,4 5,2 5 4,5 3,9 3,1 2,3
B-NM4 40/16B NM4 40/16B/A 0,55 0,75 H 7,6 7,6 7,6 7,6 7,3 7,1 6,9 6,6 6,3 5,7 5 4 2,7
B-NM4 40/16A/B NM4 40/16A/C 0,75 1 m 9,6 9,6 9,6 9,4 9,3 9,1 9 8,8 8,4 7,9 7,2 6,4 5,1 3,5
B-NM4 40/20B/B NM4 40/20B/B 1,1 1,5 13 12,9 12,7 12,6 12,4 12,2 12 11,5 10,8 10 8,6 7
B-NM4 40/20A/B NM4 40/20A/B 1,1 1,5 14,8 14,7 14,5 14,4 14,2 14 13,8 13,6 13 12,2 11,3 10
B-NM4 4025/C/C NM4 40/25C/C 1,5 2 17,4 17,3 17,2 17 16,8 16,6 16,3 16 15,1 13,8 12,1 10,4 7,2 2,8
B-NM4 4025/B/C NM4 40/25B/C 2,2 3 21,4 21,5 21,3 21,2 21 20,9 20,8 20,5 20 19,5 18,3 16,4 13,3 10 5
B-NM4 4025/A/B NM4 40/25A/B 3 4 22,9 22,8 22,9 22,8 22,5 22,5 22,2 22 21,8 21,4 20,4 18,9 16 12,6 8
Q
P2 10,8 12 13,2 15 16,8 18,9 21 24 27 30 33 37,8 42 48 54 60 66 75 84 96
B - NM4 m3/h
NM4
kW HP l/min 180 200 220 250 280 315 350 400 450 500 550 630 700 800 900 1000 1100 1250 1400 1600
B-NM4 50/16B/B NM4 50/16B/C 1,1 1,5 8,2 8,2 8,2 8,1 8 7,8 7,6 7,2 6,7 6,2 5,5 4,4 3,3
B-NM4 50/16A/B NM4 50/16A/C 1,1 1,5 9,6 9,6 9,6 9,5 9,5 9,3 9,1 8,8 8,3 7,8 7,2 6,1 4,9 3,1
B-NM4 50/20C/C NM4 50/20C/C 1,1 1,5 11,8 11,8 11,7 11,7 11,5 11,3 10,9 10,4 9,8 9 8,1 6,3 4,7
B-NM4 50/20B/C NM4 50/20B/C 1,5 2 13,4 13,4 13,4 13,3 13,1 12,9 12,6 12,1 11,5 10,8 9,9 8,2 6,4 3,7
B-NM4 50/20A/C NM4 50/20A/C 2,2 3 14,9 14,9 14,9 14,9 14,8 14,6 14,4 14 13,4 12,8 12 10,4 8,6 6
B-NM4 5025/D/B NM4 50/25D/B 2,2 3 14,5 14,4 14,3 14 13,7 13,4 13 12,2 11,2 9,7 8,1 5,4 2,3
B-NM4 5025/C/C NM4 50/25C/C 2,2 3 17,8 17,8 17,7 17,5 17,2 16,8 16,4 15,7 14,9 13,8 12,4 9,7 6,8
B-NM4 5025/B/B NM4 50/25B/B 3 4 20,7 20,7 20,7 20,6 20,4 20 19,5 18,9 18,2 17,1 15,9 13,2 10,6 5,8
B-NM4 5025/A/B NM4 50/25A/B 4 5,5 22,7 22,7 22,6 22,5 22,4 22,1 21,6 21 20,2 19,4 18,3 16,4 13,6 9
B-NM4 65/16C/C NM4 65/16C/C 1,1 1,5 H 6,1 6,1 6 6 5,9 5,8 5,6 5,3 4,8 4,2
B-NM4 65/16B/C NM4 65/16B/C 1,1 1,5 m 7,2 7,1 7,1 7 7 6,8 6,6 6,3 5,8 5,2 4,5
B-NM4 65/16A/C NM4 65/16A/C 1,5 2 8,8 8,8 8,7 8,7 8,6 8,5 8,3 8 7,6 7,1 6,4 5,2
B-NM4 65/16S/A NM4 65/16S/A 2,2 3 10,2 10,2 10,1 10,1 10 9,9 9,7 9,4 9,1 8,6 8 7 5,7
B-NM4 65/20B/A NM4 65/20B/C 2,2 3 11,7 11,7 11,6 11,6 11,5 11,3 11,0 10,6 10,1 9,5 8,7 7,4 5,8 3,3
B-NM4 65/20A/A NM4 65/20A/B 3 4 14,2 14,2 14,2 14,1 14,1 13,9 13,7 13,4 13,0 12,5 11,8 10,7 9,3 7
B-NM4 65/25B/B NM4 65/25B/B 4 5,5 17,9 18 18 18 18 17,8 17,5 17 16,3 15,4 14,4 12,5 10,4 7
B-NM4 65/25A/C NM4 65/25A/C 5,5 7,5 22,2 22,3 22,4 22,4 22,4 22,2 22 21,6 21 20,2 19,3 17,6 15,7 12,6
B-NM4 65/31C/B NM4 65/31C/B 5,5 7,5 25,8 25,7 25,5 25,3 25 24,4 23,8 22,8 21,5 20 18,2 15 11
B-NM4 65/31B/B NM4 65/31B/B 7,5 10 31 31 30,9 30,8 30,6 30,2 29,7 28,8 27,8 26,5 25 22,2 18,6
B-NM4 65/31A/B NM4 65/31A/B 9,2 12,5 35,9 35,9 35,8 35,7 35,5 35,1 34,6 33,8 32,8 31,6 30,2 27,8 25
Q
P2 30 33 37,8 42 48 54 60 66 75 84 96 108 120 132 150 168 180 192 210
m3/h
B-NMS4 NM4 - NMS4
kW HP l/min 500 550 630 700 800 900 1000 1100 1250 1400 1600 1800 2000 2200 2500 2800 3000 3200 3500
NM4 80/16C/C 1,1 1,5 6,1 6,1 5,9 5,8 5,5 5,2 4,9 4,6 4 3,3
NM4 80/16B/C 1,5 2 7,8 7,7 7,6 7,5 7,3 7 6,8 6,4 5,9 5,2 4,1
NM4 80/16A/C 2,2 3 10 10 9,9 9,8 9,7 9,5 9,3 9 8,5 8 7 5,9
B- NM4 80/20C NM4 80/20C/B 2,2 3 10,3 10,2 10,1 10 9,8 9,5 9,1 8,6 7,7 6,6 4,6
B- NM4 80/20B NM4 80/20B/A 3 4 12,1 12 11,9 11,8 11,7 11,4 11,1 10,6 9,8 9 7,5 5,7
B- NM4 80/20A NM4 80/20A/A 4 5,5 13,9 13,8 13,7 13,6 13,5 13,3 13 12,6 11,8 11 9,6 7,9 6
B- NM4 80/25C NM4 80/25C/A 4 5,5 16,9 16,8 16,7 16,6 16,3 15,9 15,4 14,8 13,9 12,7 11,1 9,3 7,2
B- NMS4 80/250B/A NM4 80/25B/B 5,5 7,5 20,7 20,6 20,5 20,4 20,3 20 19,6 19,1 18,2 17,1 15,4 13,5 11,4 9*
H
B- NMS4 80/250A/A NM4 80/25A/B 7,5 10 23,7 23,7 23,6 23,5 23,3 23 22,7 22,2 21,5 20,5 19 17,2 15,1 12,7*
m
B- NM4 80/31C/B NM4 80/31C/B 9,2 12,5 25,7 25,8 25,8 25,8 25,8 25,6 25,4 25 24,4 23,6 22,2 20,4 18,3 15,9
B- NMS4 80/315B/B NM4 80/31B 11 15 30,3 30,5 30,6 30,7 30,7 30,7 30,5 30,2 29,6 28,8 27,5 25,9 24,1 22
B- NMS4 80/315A/B NM4 80/31A 15 20 36,3 36,4 36,5 36,6 36,6 36,5 36,4 36,1 35,6 35 33,9 32,5 30,9 29 25,3
B- NMS4 80/315S NMS4 80/315S 18,5 25 39,1 39,2 39,3 39,4 39,5 39,4 39,3 39,2 38,7 38,1 37,1 35,7 34,1 32,1 28,3 22,5*
B- NMS4 80/400C/B NMS4 80/400C/B 18,5 25 42,8 42,8 42,8 42,8 42,7 42,5 42,2 41,8 41 39,8 37,9 35,4 32,4 29,1
B- NMS4 80/400B/B NMS4 80/400B/B 22 30 48,2 48,2 48,2 48,2 48,1 47,9 47,7 47,3 46,6 45,7 44,1 42,1 39,5 36,3 30,5
B- NMS4 80/400A/B NMS4 80/400A/B 30 40 61,4 61,5 61,5 61,6 61,6 61,5 61,3 61,1 60,7 60,1 59 57,6 55,8 53,7 49,5
B- NMS4 80/400S NMS4 80/400S 37 50 61,4 61,5 61,5 61,6 61,6 61,5 61,3 61,1 60,7 60,1 59 57,6 55,8 53,7 49,5 43,9 39,2*
51
NM4, NMS4 Close Coupled Centrifugal Pumps
Q
P2 48 54 60 66 75 84 96 108 120 132 150 168 180 192 210 240 270 300 330
m3/h
B-NMS4 NM4 - NMS4
kW HP l/min 800 900 1000 1100 1250 1400 1600 1800 2000 2200 2500 2800 3000 3200 3500 4000 4500 5000 5500
B- NM4 100/20C/A NM4 100/20C/A 3 4 9,4 9,3 9,2 9,1 8,9 8,5 8 7,3 6,5 5,6 4
B- NM4 100/20B/A NM4 100/20B/A 4 5,5 12 11,9 11,8 11,7 11,5 11,2 10,7 10 9,3 8,4 6,7 4,5
B- NM4 100/20A/C NM4 100/20A/C 5,5 7,5 15,2 15,2 15,1 15 14,9 14,7 14,3 13,8 13,1 12,2 10,7 9 7,5* 6*
B- NMS4 100/250B/A NM4 100/25B/B 7,5 10 19,5 19,5 19,4 19,3 19 18,7 18,2 17,5 16,6 15,6 13,8 11,7 10 8,4 5,5
B- NMS4 100/250A/A NM4 100/25A/B 9,2 12,5 22,3 22,3 22,2 22,1 21,9 21,7 21,2 20,5 19,8 18,8 17,1 15 13,4 11,7 8,9
H
B- NMS4 100/315C/A NM4 100/31C 11 15 26,9 26,9 26,8 26,6 26,2 25,7 24,9 23,8 22,7 21,3 18,9 15,9 13,7 11,3*
m
B- NMS4 100/315B/A NM4 100/31B 15 20 31,5 31,5 31,4 31,3 31,2 30,8 30,2 29,3 28,2 26,9 24,6 21,8 19,8 17,6* 14*
B- NMS4 100/315A/A NMS4 100/315A/A 18,5 25 36,9 36,9 36,8 36,7 36,6 36,4 36 35,3 34,5 33,4 31,4 29 27,2 25,3* 22,2*
B- NMS4 100/400C/A NMS4 100/400C/A 22 30 41,3 41,2 41,1 41 40,7 40,4 39,8 39 38 36,5 34 31 28,7 26
B- NMS4 100/400B/A NMS4 100/400B/A 30 40 50,2 50,1 50 49,9 49,7 49,4 48,8 48 47,1 46 44 41,3 39,5 37 33,5*
B- NMS4 100/400A/A NMS4 100/400A/A 37 50 58,2 58,1 58 57,9 57,8 57,6 57,2 56,3 55,7 54,5 52,7 50,5 49 47 44*
Q
P2 84 96 108 120 132 150 168 180 192 210 240 270 300 330 360 390 420 450 480
m3/h
B-NMS4 NM4 - NMS4
kW HP l/min 1400 1600 1800 2000 2200 2500 2800 3000 3200 3500 4000 4500 5000 5500 6000 6500 7000 7500 8000
B- NMS4 125/250E/A NM4 125/25E/B 5,5 7,5 11 10,8 10,5 10,1 9,7 9,1 8,3 7,8 7,2 6,2 4,4
B- NMS4 125/250D/A NM4 125/25D/B 7,5 10 14 13,9 13,7 13,4 13 12,4 11,6 11 10,4 9,4 7,4 5,1
B- NMS4 125/250C/A NM4 125/25C/B 9,2 12,5 16,7 16,6 16,4 16,2 15,9 15,4 14,6 14,1 13,5 12,5 10,4 8,2 5,8
B- NMS4 125/250B/A NM4 125/25B 11 15 19,3 19,2 19,1 18,9 18,7 18,2 17,5 17 16,3 15,3 13,3 10,9 8,2
B- NMS4 125/250A/A NM4 125/25A 15 20 22,7 22,7 22,6 22,4 22,2 21,8 21,2 20,8 20,1 19,3 17,4 15 12,4 9,3
B- NMS4 125/315C/A NMS4 125/315C/A 18,5 25 27,9 27,8 27,7 27,6 27,2 26,5 25,6 24,9 24 22,8 20,2 17 13,5 9,5*
B- NMS4 125/315B/A NMS4 125/315B/A 22 30 31,8 31,7 31,6 31,5 31,1 30,6 29,7 29,1 28,5 27,3 24,9 22 18,5 14,3*
B- NMS4 125/315A/A NMS4 125/315A/A 30 40 36,8 36,8 36,7 36,6 36,4 35,9 35,2 34,7 34,2 33,2 31 28,4 25,3 21,6*
B- NMS4 125/400C/A NMS4 125/400C/A 37 50 H 45,4 45,3 45,2 45,1 44,9 44,4 43,7 43 42 40 37 33 28,5* 23,5*
B- NMS4 125/400B/A NMS4 125/400B/A 45 60 m 51,4 51,3 51,2 51,1 50,9 50,4 49,7 49 48,2 46,8 44 40,5 36* 31,5*
B- NMS4 125/400A/A NMS4 125/400A/A 55 75 59,2 59,1 59 58,9 58,7 58,2 57,7 57,2 56,7 55,7 53,5 50,5 46,5* 42,5*
B- NMS4 150/315D/A NMS4 150/315D/A 18,5 25 22,8 22,6 22,3 22 21,7 21,1 20 18,6 17 15,1 13 10,6 8*
B- NMS4 150/315C/A NMS4 150/315C/A 22 30 25,6 25,4 25,1 24,9 24,7 24,2 23,3 22 20,4 18,5 16,5 14,1 11,6* 8,9*
B- NMS4 150/315B/A NMS4 150/315B/A 30 40 30,6 30,6 30,5 30,3 30,1 29,7 29 27,9 26,5 24,9 23 20,8 18,3* 15,4*
B- NMS4 150/315A/A NMS4 150/315A/A 37 50 35,6 35,6 35,5 35,4 35,3 35,2 34,6 33,7 32,5 31 29,2 27,1 24,7* 21,8* 18,5*
B- NMS4 150/400C/A NMS4 150/400C/A 45 60 45 44,9 44,7 44,5 44 43,5 42,5 40,5 38,5 36 33,5 30,5 27* 23,5* 19,5*
B- NMS4 150/400B/A NMS4 150/400B/A 55 75 50,8 50,7 50,5 50,3 50 49,5 48,5 47 45 43 40,5 38 35* 32* 28,5*
B- NMS4 150/400A/A NMS4 150/400A/A 75 100 58,8 58,7 58,6 58,5 58,3 57,9 57 55,5 54 52 49,5 47 44* 41* 37,5
NM4, NMS4 Standard construction. P2 Rated motor power output. Maximum suction lift 1-2 m.
H Total head in m.
*
B-NM4, B-NMS4 Bronze construction. Tolerances according to UNI EN ISO 9906:2012
Rated currents
kW HP IN A IN A IA/IN kW HP IN A IN A IA/IN
0,25 0,34 1,4 0,8 3,7 4 5,5 8,3 4,8 7,2
0,37 0,5 1,65 0,95 4,2 5,5 7,5 12,5 7,2 7,2
0,55 0,75 2,6 1,5 4,8 7,5 10 16 9,2 7,1
0,75 1 3,3 1,9 7,2 9,2 12,5 20,5 11,8 7,4
1,1 1,5 5 2,9 6,6 11 15 22,5 13 9,6
1,5 2 6 3,5 8,3 15 20 29 16,7 9,1
2,2 3 8,6 5 8,6 18,5 25 35 20,5 7,2
3 4 11,1 6,4 5,8 22 30 41 24 6,8
30 40 55 32 7,3
37 50 66 38,5 6,4
45 60 80 46,5 6,4
55 75 96 56 6,8
75 100 133 77 6,9
Hm
H ft
H ft
15
54
4
14
4 10
50
12 2
5
3 10 0 0
3 3
0
Q m /h 1 2 3 4 5 6 0
Q m /h 2 3 4 5 6 7 8
0 l/min 20 40 60 80 100 0 l/min 20 40 60 80 100 120
0 l/s 0.2 0.4 0.6 0.8 1 1.2 1.4 1.6 0 l/s 0.4 0.6 0.8 1 1.2 1.4 1.6 1.8 2 2.2
0.2 0.3 0.4
A
0.2 0.3
0.2 B
A
P kW
P kW
P HP
P HP
0.1 0.2
0.1 0.1
0.1
0 0 0 0
4 8 25
NPSH m
NPSH m
3 10 6 20
NPSH ft
NPSH ft
15
2 4
5 10
1 2
5
0 72.071
0 0 72.072
0
0 Q m /h 1
3 2 3 4 5 6 0 Q m3/h 2 3 4 5 6 7 8
0 U.S. g.p.m. 25 50
15
A Ø200
B Ø194 NM4 25/200
40
C Ø184
10
30
Hm
H ft
20
5
10
0 0
0 3 5 10 15
Qm /h
0 l/min 50 100 150 200 250
0,7
0,6 A
0,8
0,5 B
P kW
0,6
P HP
0,4 C
0,3 0,4
0,2
0,2
0,1
80
60
η (%)
40
20 C B A
0
8 25
NPSH m
6 20
NPSH ft
15
4
10
2
5
0 0
0 Q m /h
3 5 10 72.076N 15
53
NM4, NMS4 Close Coupled Centrifugal Pumps
A Ø 164 50 50
55 58
60 NM4 32/16 30 15 A Ø 204 NM4 32/20
62
8 η 62% B Ø 195
B Ø 150 62 40
35 40
60 45 48
50 52
58 10
η 53%
Hm
Hm
55 30
20
H ft
H ft
6 52
5048
45
40
35
20
5
4
10
10
2 0 0
3 3
0
Q m /h 2 4 6 8 10 12 0
Q m /h 2 4 6 8 10 12 14
0 l/min 50 100 150 200 0 l/min 50 100 150 200
P kW
B 0.6 0.8
P HP
P HP
0.3 B
0.2
0.4 0.6
0.2
0.1 0.4
0.1 0.2
0.2
0 0 0 0
8 25 8 25
NPSH m
NPSH m
6 20 6 20
NPSH ft
NPSH ft
15 15
4 4
10 10
2 2
5 5
0 72.074
0 0 72.075
0
0 Q m /h 2
3 4 6 8 10 12 0 Q m3/h 2 4 6 8 10 12 14
00 U.S. g.p.m.
U.S. g.p.m.20 30 5040 50 60 70 100 80 90 0 U.S. g.p.m. 20 30 40 50 60 70 80 90
10
12 40 18
A Ø 163 55 60
30
10 A Ø 167
64 66 NM440/16
NM4
67
40/16 35
16 NM4 40/20
A Ø 204 40 50
50
B Ø 153 η 67% 30 54 56
8
66 14 η 58%
8 B Ø 151 64 B Ø 195
C Ø 143 25 56
54
C Ø 137 60 12 50 40
ft ft
HHmm
20
Hm
6
HH
20
H ft
6
15 10
4 55 30
10 40
8
42
5
10 6 20
0 0
0 3 10 20 30
2 0 Qm /h
l/min 100 200 300 400 500 4
3
0 5 10 15 20 0 3 5 10 15 20
0,6 Q m /h A350
0,8 Q m /h
0,50 l/min50 100 150 200 250 300 0 l/min50 100 150 200 250 300 350
0,6
0,4
0 l/s 1 2 3 4 5B 6 0 l/s 1 2 3 4 5 6
P kW
P HP
0,3 C 0,4
0.7 1.2 1.6
0,2
0.6 0,2
0,1 A 0.8 1.0 A
0.50 0 B
B 0.6 0.8
P kW
1.0
P kW
80
P HP
P HP
0.4
C 0.6
0.3
60 0.4
0.4
0.2
η (%)
40 C B A 0.2
0.1 0.2
η
20
0 0 0 0
80 25 8 25
8 25
NPSHmm
NPSH m
66 20
20 6 20
NPSHftft
NPSH ft
NPSH
15
15 15
NPSH
44 4
10
10 10
22 2
55 5
00 72.076
00 0 0
72.077
00 Q
Qmm/h/h
33 5 10 10 20
15 72.076N
20 30 0 Q m3/h 5 10 15 20
54
NM4, NMS4 Close Coupled Centrifugal Pumps
H ft
H ft
40 6 20
Hm
Hm
10 15
30
4
20 10
5
2
10 5
0 0 0 0
0 m 3/h 10 20 30 0 m3/h 10 20 30 40 50
0
Q l/min 100 200 300 400 500 0
Q l/min 200 400 600 800
3 4 1,5 2
A 1,2
2 3 1,5
0,9 A
P kW
P kW
P HP
P HP
B 2 1
C 0,6 B
1
1 0,3 0,5
0 0 0 0
60 80
60 A
40 A B
η (%)
η (%)
40
20 B
C 20
0 0
9 9
25 25
NPSH m
NPSH m
6 20 6 20
NPSH ft
NPSH ft
15 15
3 10 3 10
5 5
0 0 0 0
0 Q m 3/h 10 20 72.076N 30 0 Q m3/h 10 20 30 40 72.076N
50
0 U.S. g.p.m. 50 100 150 200 0 U.S. g.p.m. 50 100 150 200
16 25 80
A Ø 209 50 A Ø 255
14 B Ø 200 NM4 50/20 45 B Ø 245
NM4 50/25 70
40 20
C Ø 188 C Ø 229
12 60
35
10 15 D Ø 209 50
30
H ft
H ft
8 25 40
Hm
Hm
6 20 10
30
15
4 20
10 5
2 5 10
0 0 0 0
0 3 10 20 30 40 50 0 3 10 20 30 40 50
Qm
/h
Qm
/h
0 l/min 200 400 600 800 0 l/min 200 400 600 800
2 4
2,5 5
A A
1,5 2 3 4
B B
P kW
P kW
1,5 3
P HP
P HP
1 C 2 C
1 D 2
0,5 1
0,5 1
0 0 0 0
80 70
60
60
A A
40
η (%)
η (%)
40 C B
B
20 C 20
D
0 0
8 25 9
25
NPSH m
NPSH m
6 20
20
NPSH ft
NPSH ft
6
15
4 15
10 3 10
2 5 5
0 0 0 0
72.076N 72.076N
0 Q m3/h 10 20 30 40 50 0 Q m3/h 10 20 30 40 50
55
NM4, NMS4 Close Coupled Centrifugal Pumps
H ft
H ft
6 20 8
Hm
Hm
15 6 20
4
10 4
10
2
5 2
0 0 0 0
0 3 30 60 90 0 3 20 40 60 80 100
0
Qm /h
l/min 300 600 900 1200 1500 0
m /h
Q l/min 500 1000 1500
3 4
3 A 4
3
2 S B 3
P HP
2
P kW
P kW
P HP
A 2
2
1 B 1
C 1 1
0 0 0 0
80 80
A
60 C B A 60
S
η (%)
η (%)
40 40 B
20 20
0 0
8 25 8 25
NPSH m
NPSH m
6 20 6 20
NPSH ft
NPSH ft
15 15
4 4
10 10
2 2
5 5
0 0 0 0
0 Q m 3/h 30 60 72.082N 90 0 Q m3 /h 20 40 60 80 72.082N 100
0 U.S. g.p.m. 100 150 200 250 300 350 400 0 U.S. g.p.m. 100 200 300 380
24 40
A Ø 252
NM4 65/25 A Ø 321.5 50
60
64 NM4 65/31 120
20
B Ø 230 68
60
B Ø 302 η 69%
16 30 68 100
C Ø 278
H ft
40 64
Hm
12
Hm
H ft
80
8 60
20 20
60
4
50
0 0 40
0 3
m /h 20 40 60 80 100
0
Q l/min 500 1000 1500
10
0 3 20 30 40 50 60 70 80 90
Q m /h
6 8
0 l/min 500 1000 1500
A
0 l/s 5 10 15 20 25
B 6
P HP
4
P kW
4 10
2 A 12
2 8
B 10
0 0
6
P kW
8
P HP
C
80 6
A 4
60 4
η (%)
2
40 2
B
0 0
20
0 4
12
8 25
NPSH m
3 10
NPSH ft
NPSH m
6 20 8
NPSH ft
15 2 6
4
10 1 4
2 2
5
0 0
0 0 0 20 30 40 50 60 70 80 72.087
90
0 Q m3 /h 20 40 60 80 72.082N 100 Q m3/h
56
NM4, NMS4 Close Coupled Centrifugal Pumps
H ft
20 10
Hm
6
Hm
H ft
70 30
15 9
4 8 65
10
7 60
2
5 6 20
0 0 5
0 3 20 40 60 80 100 120
Qm /h
0 l/min 400 800 1200 1600 2000 4
0 3
3 4 Q m /h 20 40 60 80 100 120
0 l/min 500 1000 1500 2000
A 3
2 0 l/s 10 20 30
P kW
P HP
B 2
4
1 C A 5
1
3 B 4
0 0
P kW
P HP
C 3
80 2
C B A 2
60 1
η (%)
1
40
0 0
20
0 8 25
8 25
NPSH m
6 20
NPSH ft
NPSH m
6 20
15
NPSH ft
15 4
4 10
10 2
2 5
5
0 0
0 0 0 72.086
0 Q m 3/h 20 40 60 80 100 72.085N 120 Q m3/h 20 40 60 80 100 120
50
H ft
15
40
10
30
20
5
0 3 50 100 150
Q m /h
0 l/min 500 1000 1500 2000 2500
0 l/s 10 20 30 40
8
A 10
6 8
B
P kW
P HP
6
4 C
4
2
2
0 0
8 25
NPSH m
6 20
NPSH ft
15
4
10
2
5
0 72.088
0
0 Q m3/h 50 100 150
57
NM4, NMS4 Close Coupled Centrifugal Pumps
50 B Ø 363 S Ø 403
B Ø 295
30 100 150
C Ø 345
Hm
H ft
Hm
C Ø 277 40
H ft
80
30 100
20
60
20
50
40
10 10
0 3 50 100 150 180 0 3 50 100 150 180
0
Q m /h 500 1000 1500 2000 2500 3000 0
Q m /h 500 1000 1500 2000 2500 3000
20 l/min 40 l/min
S S
16 A
A 20 30 40
P kW
P kW
12
P HP
P HP
B B
20
8 C 10 C 20
4 10
0 0 0 0
80 80
A A
70 70
B S
(%)
(%)
60 C S 60 C B
50 50
40 40
10 10
S 30 S 30
8 8
NPSH m
NPSH m
NPSH ft
NPSH ft
6 20 6 20
4 C 4 C
10 10
2 2
0 0 0 0
0 Q m3/h 50 100 150 180 0 Q m3/h 50 100 150 180
58
NM4, NMS4 Close Coupled Centrifugal Pumps
Hm
73 70
H ft
H ft
70 30 40
65
60
10
30
20
5
20
5
10
10
0 0 0 0
3 3
0 50 100 150 200 0 50 100 150 200
Q m /h Q m /h
0 l/min 500 1000 1500 2000 2500 3000 0 l/min 1000 2000 3000
0 l/s 10 20 30 40 50 0 l/s 10 20 30 40 50 60
6 8 10
A A 12
5 8
6 B 10
4
P kW
P kW
B 6 8
P HP
P HP
3 C 4
4 6
2 4
2 2
1 2
0 0 0 0
8 25 8 25
NPSH m
NPSH m
6 20 6 20
NPSH ft
NPSH ft
15 15
4 4
10 10
2 2
5 5
0 72.091
0 0 72.092
0
0 Q m3/h 50 100 150 200 0 Q m3/h 50 100 150 200
0 U.S. g.p.m. 200 400 600 800 0 U.S. g.p.m. 200 400 600 800
40 60
A Ø 328 65 70 73 A Ø 405
75 NM(S)4 100/315 120 NMS4 100/400 180
B Ø 377 55 60
B Ø 306 50 64
67 160
30 75 100
68
η 77%
C Ø 286 73
C Ø 347 67 140
Hm
Hm
70
H ft
H ft
80 40
64 120
η 69%
20 65
60 100
30
60
80
40
10 20
3
0 50 100 150 200 0 m3/h 50 100 150 200
Q m /h Q
0 l/min 1000 2000 3000 0 l/min 1000 2000 3000
0 l/s 10 20 30 40 50 60 0 l/s 10 20 30 40 50 60
20 40
A 25 A 50
20 30 B 40
B
P kW
P kW
P HP
P HP
C 15 C 30
10 20
10 20
10
5 10
0 0 0 0
10 8 25
30
NPSH m
NPSH m
6 20
NPSH ft
NPSH ft
20 15
5 4
10
10 2
5
0 72.093
0 0 0
72.094
0 Q m3/h 50 100 150 200 0 Q m3/h 50 100 150 200
59
NM4, NMS4 Close Coupled Centrifugal Pumps
Hm
H ft
H ft
40 20
E Ø 203 60 60 60
10
40
20 10
5
20
0 0 0 0
3 3
0 100 200 300 0 100 200 300
Q m /h Q m /h
0 l/min 1000 2000 3000 4000 5000 0 l/min 1000 2000 3000 4000 5000
0 l/s 20 40 60 80 0 l/s 20 40 60 80
18 30 40
A
A 20 B
30
B 20 C
P kW
P kW
P HP
P HP
10
C 20
D 10
E 10
10
0 0 0 0
8 8
NPSH m
NPSH m
6 20 6 20
NPSH ft
NPSH ft
4 4
10 10
2 2
0 72.095
0 0 72.096
0
0 Q m3/h 100 200 300 0 Q m3/h 100 200 300
60 65 200
60 A Ø 405 70
73 NMS4 125/400
75
η 76% 180
B Ø 380 75
50 73 160
C Ø 364 70
Hm
140
H ft
40
66 120
30 100
60
80
20
3
0
Q m /h 50 100 150 200 250 300 350
0 l/min 1000 2000 3000 4000 5000 5800
0 l/s 10 20 30 40 50 60 70 80 90
60 80
A
50
B 60
40
P kW
C
P HP
30 40
20
20
10
0 0
8
NPSH m
6 20
NPSH ft
4
10
2
0 72.097
0
0 Q m3/h 50 100 150 200 250 300 350
60
NM4, NMS4 Close Coupled Centrifugal Pumps
Hm
65
H ft
H ft
20
60 70
30 100
60
40 65
10 60
20
20
50
0 0 10
3 3
0 100 200 300 400 500 0 100 200 300 400 500
Q m /h Q m /h
0 l/min 2000 3000 4000 5000 6000 7000 8000 0 l/min 2000 3000 4000 5000 6000 7000 8000
P kW
P HP
P HP
C 30 C
20 40 50
D
20
10 20
10
0 0 0 0
8 25 10
30
NPSH m
NPSH m
6 20
NPSH ft
NPSH ft
15 20
4 5
10
2 10
5
0 72.098
0 0 72.099
0
0 Q m3/h 100 200 300 400 500 0 Q m3/h 100 200 300 400 500
61
NM4 Close Coupled Centrifugal Pumps
h2
DN1 g1 h1
4.93.098
m2 n3
s b
m1 n2
w n1
Standard construction
mm
DN1 DN2
Picture NM4 DN1 kg
a fM h1 h2 H m1 m2 n1 n2 n3 b s l1 l2 w g
ISO 228
NM4 25/12A/A 56 313 90 140 199 37,5 27,5 170 130 9 38 9,5 85 88 250 10 13,5
NM4 25/160AE-BE 56 380 100 160 228 37,5 27,5 190 150 30 38 9,5 102 102 250 10 17,5
1 G 11/2 G 1
NM4 25/200B/A-C/A 63 385 125 180 253 45 32,5 245 200 49 45 11,5 125 125 250 11 23-21,5
NM4 25/200A/C 63 425 125 180 253 45 32,5 245 200 49 45 11,5 125 125 250 11 27
2 3
fM l1 l2
fM
a
a l1 l2
DN2 DN2
DN2 DN2
A
g2*
h2
DN1
h2
DN1
H A
H
h1
4.93.061.2 g1 h1
4.93.078.2 g2
n3 m2 s s1
m2 s b h4
m1 b b1
m1 n2 w m5 w1 n2 n5
w n1 m4 n1
Standard construction
mm
Picture NM4 kg
DN1 DN2 a fM h1 h2 H h4 m1 m2 n1 n2 n3 n5 w1 b b1 s s1 l1 l2 w m4 m5 g1 g2
NM4 32/16AE-BE 50 32 80 410 132 160 260 - 100 70 240 190 47 - - 50 -- 14 - 120 120 255 - - 12 - 30,5-30
NM4 32/20BE 410 35 DG
50 32 80 160 180 288 - 100 70 240 190 62 - - 50 - 14 - 140 140 255 - - 12 -
NM4 32/20A/B 450 42
NM4 40/16B/A-C/A 65 40 80 410 132 160 268 - 100 70 240 190 47 - - 50 - - 32,4-30,6
- 14 - 121 121 255 10 -
NM4 40/16A/C 450 39
NM4 40/20A/B-B/B 65 40 100 495 160 180 298 - 100 70 265 212 62 - - 50 - 14 - 142 142 295 - - 12 - 49,6-49 W DN
NM4 40/25C/C 495 308 300 67,7 DK
65 40 100 180 225 - 125 95 320 250 60 - - 65 - 14 - 175 175 - - 15 -
NM4 40/25A/B-B/C 528 340 279 78-76,6
4.93.094 DE
NM4 50/16A/C-B/C 65 50 100 495 160 180 298 - 100 70 265 212 62 - - 50 - 14 - 126 140 295 - - 12 - 40-39,5
NM4 50/20B/C-C/C 505 288 62 310 52,5-44,5
NM4 50/20A/C
65 50 100
528
160 200
320
- 100 70 265 212
60
- - 50 - 14 - 140 153
279
- - 14 -
57 mm
NM4 50/25C/C-D/B 68
65 50 100 528 180 225 340 - 125 95 320 250 60 - - 65 - 14 - 175 175 279 - - 15 -
NM4 50/25A/B-B/B 85,5-78
NM4 65/16A/C-B/C-C/C 495 288 62 300 53-49,3-48,7 DN DG DK DE W
80 65 100 160 200 - 125 95 280 212 - - 65 - 14 - 140 161 - - 12 -
NM4 65/16S/A 528 320 60 279 62,3
NM4 65/20A/B-B/C 80 65 100 528 180 225 340 - 125 95 320 250 60 - - 65 - 14 - 159 178 279 - - 12 - 69-68,7
N°
NM4 65/25B/C 543 360 294 97,4
2 80 65 100
200 250 - 160 120 360 280 60 - - 80 - 18 - 179 195 - - 15 - 32 76 100 140 4 19 18
NM4 65/25A/B 645 385 405 118
NM4 65/31C/B-B/B 670 415 153-164 40 84 110 150 4 19 18
80 65 125 225 280 410 - 160 120 400 315 75 - - 80 - 18 - 220 220 - - 20 -
NM4 65/31A/B 720 465 176 50 99 125 165 4 19 20
NM4 80/16B/C-C/B 520 308 62 300 59,6-55,6 65 118 145 185 4 19 20
100 80 125 180 225 - 125 95 320 250 - - 65 - 14 - 153 181 - - 12 -
NM4 80/16A/C 553 340 60 279 69,8
80 132 160 200 8 19 22
NM4 80/20A/A-B/A-C/B 100 80 125 563 180 250 340 - 125 95 345 280 60 - - 65 - 14 - 170 194 289 - - 15 - 91-82-74,5
100 156 180 220 8 19 24
NM4 80/25C/A 563 360 289 102
100 80 125 200 280 - 160 120 400 315 60 - - 80 - 18 - 191 210 - - 20 -
NM4 80/25B/B-A/B 670 385 415 124-135 125 184 210 250 8 19 24
NM4 80/31C/B 100 80 125 720 250 315 435 - 160 120 400 315 90 - - 80 - 18 - 222 234 465 - - 17 - 181 150 211 240 285 8 23 26
3 NM4 80/31A-B 100 80 125 787 260 315 466 10 160 120 400 315 - 254 20 80 74 18 14 222 234 147 435 395 - 6 269-248 200 266 295 340 8 23 30
NM4 100/20B/A-C/A 563 360 289 99-90
125 100 125 200 280 - 160 120 360 280 60 - - 80 - 18 - 180 212 - - 20 -
NM4 100/20A/C 665 385 400 109
2
NM4 100/25B/B 685 415 143
125 100 140 225 280 410 - 160 120 400 315 75 - - 80 - 18 - 205 233 - - 20 -
NM4 100/25A/B 735 465 152
3 NM4 100/31B-C 125 100 140 802 260 315 466 10 160 120 400 315 - 254 20 80 74 18 14 230 250 147 435 395 - 6 280-261
NM4 125/25E/B-D/B 685 415 149-161
2 150 125 140 250 355 435 - 160 120 400 315 90 - - 80 - 18 - 235 268 - - 20 -
NM4 125/25C/B 735 465 173
3 NM4 125/25A-B 150 125 140 802 260 355 466 10 160 120 400 315 - 254 20 80 74 18 14 235 268 147 435 395 - 6 261-243
62
NM4 Close Coupled Centrifugal Pumps
AG
AG
fM
AS DG
AS
fM l1 l2
l1 l2
a a W DN
DN2 DN2 DK
A
4.93.094 DE
g2*
mm
H h2 h2
Fori
DN1
DN1 H A
DN DG DK DE N° Ø W
g1
h1 h1 32 76 100 140 4 19 18
4.93.083.1
4.93.078.2 g2 40 84 110 150 4 19 18
m2 s n3 b 50 99 125 165 4 19 20
m2 s s1
h4 65 118 145 185 4 19 20
m1 n2 m1 b b1
w m5 w1 n2 n5 80 132 160 200 8 19 22
w n1
m4 n1 100 156 180 220 8 19 24
125 184 210 250 8 19 24
mm
Picture NM4 EI kg
DN1 DN2 a fM AG AS h1 h2 H h4 m1 m2 n1 n2 n3 n5 w1 b b1 s s1 l1 l2 w m4 m5 g1 g2
NM4 EI 32/16AE-BE 50 32 80 440 190 105 132 160 418 - 100 70 240 190 47 - - 50 -- 14 - 120 120 255 - - 12 - 37-36,4
NM4 EI 32/20BE 440 40,9
50 32 80 190 105 160 180 466 - 100 70 240 190 62 - - 50 - 14 - 140 140 255 - - 12 -
NM4 EI 32/20A/B 450 48,4
NM4 EI 40/16B/A-C/A 65 40 80 440 - - - - - - 38,4-36,4
190 105 132 160 418 100 70 240 190 47 - 50 14 - 121 121 255 10
NM4 EI 40/16A/C 450 45,4
NM4 EI 40/20A/B-B/B 65 40 100 495 190 105 160 180 547 - 100 70 265 212 62 - - 50 - 14 - 142 142 295 - - 12 - 57,4-56,9
NM4 EI 40/25C/C 495 190 105 474 300 74
65 40 100 180 225 - 125 95 320 250 60 - - 65 - 14 - 175 175 - - 15 -
NM4 EI 40/25A/B-B/C 528 210 118 502 279 85,5-85
NM4 EI 50/16A/C-B/C 65 50 100 495 190 105 160 180 454 - 100 70 265 212 62 - - 50 - 14 - 126 140 295 - - 12 - 46,4-46
NM4 EI 50/20B/C-C/C 505 190 105 454 62 310 59-51
65 50 100 160 200 - 100 70 265 212 - - 50 - 14 - 140 153 - - 14 -
NM4 EI 50/20A/C 528 210 118 482 60 279 63,4
NM4 EI 50/25C/C-D/B 74,4-74,4
65 50 100 528 210 118 180 225 502 - 125 95 320 250 60 - - 65 - 14 - 175 175 279 - - 15 -
NM4 EI 50/25A/B-B/B 93,0-85,5
NM4 EI 65/16B/C-C/C 495 190 105 454 62 300 54,4-54,4
NM4 EI 65/16A/C 80 65 100 495 190 105 160 200 454 - 125 95 280 212 62 - - 65 - 14 - 140 161 300 - - 15 - 60,9
NM4 EI 65/16S/A 528 210 118 528 60 279 61,4
NM4 EI 65/20A/B-B/C 80 65 100 528 210 118 180 225 502 - 125 95 320 250 60 - - 65 - 14 - 159 179 279 - - 12 - 81 -67,4
NM4 EI 65/25B/C 543 210 118 522 294 104,5
1 80 65 100 - - - - - - -
NM4 EI 65/25A/B 645 281 153 200 250 593 160 120 360 280 60 - 80 18 179 195
405
15 130,8
NM4 EI 65/31C/B-B/B 670 281 153 415 179-168
80 65 125 281 153 225 280 618 - 160 120 400 315 75 - - 80 - 18 - 220 220 - - 20 -
NM4 EI 65/31A/B 720 465 190,8
NM4 EI 80/16B/C-C/B 520 190 105 454 62 300 67,4-59,4
100 80 125 180 225 - 125 95 320 250 - - 65 - 14 - 153 181 - - 12 -
NM4 EI 80/16A/C 553 210 118 545 60 279 71,9
NM4 EI 80/20A/A-B/A-C/B 100 80 125 563 210 118 180 250 502 - 125 95 345 280 60 - - 65 - 14 - 170 194 289 - - 15 - 99-90-81
NM4 EI 80/25C/A 563 210 118 522 289 109,5
100 80 125 200 280 - 160 120 400 315 60 - - 80 - 18 - 191 210 - - 20 -
NM4 EI 80/25B/B-A/B 670 281 153 593 415 150-139
NM4 EI 80/31C/B 100 80 125 745 281 153 250 315 613 - 160 120 400 315 90 - - 80 - 18 - 222 234 465 - - 17 - 195,8
NM4 EI 80/31B 281 153 671 283
2 100 80 125 790 350 190 260 315 751 10 160 120 400 315 - 254 20 80 74 18 14 222 234 147 435 395 - 6
NM4 EI 80/31A 304
NM4 EI 100/20B/A-C/A 563 210 118 522 289 107-97,5
125 100 125 200 280 - 160 120 360 280 60 - - 80 - 18 - 180 212 - - 20 -
NM4 EI 100/20A/C 665 281 153 593 400 123,8
1
NM4 EI 100/25B/B 685 415 166,8
125 100 140 281 153 225 280 618 - 160 120 400 315 75 - - 80 - 18 - 205 233 - - 20 -
NM4 EI 100/25A/B 735 465 157,8
NM4 EI 100/31C 281 153 671 296
2 125 100 140 805 260 315 10 160 120 400 315 - 254 20 80 74 18 14 230 250 147 435 395 - 6
NM4 EI 100/31B 350 190 751 315
NM4 EI 125/25E/B-D/B 685 281 153 415 164-176
1 150 125 140 250 355 643 - 160 120 400 315 90 - - 80 - 18 - 235 268 - - 20 -
NM4 EI 125/25C/B 735 281 153 465 187,8
NM4 EI 125/25B 281 153 671 378
2 150 125 140 805 260 355 10 160 120 400 315 - 254 20 80 74 18 14 235 268 147 435 395 - 6
NM4 EI 125/25A 350 190 751 296
63
NMS4 Close Coupled Centrifugal Pumps
Flanges EN 1092-2
DG
fM W DN
a l1 l2 DK
DN2 DN2 DE
4.93.094
mm
DN1
h2
Holes
H DN DG DK DE W
A
N°
h1
32 76 100 140 4 19 18
g2 40 84 110 150 4 19 18
4.93.466.1
A 50 99 125 165 4 19 20
m2 s s1
m1 b b1 65 118 145 185 4 19 20
w m5 w1 n2 n5 80 132 160 200 8 19 22
m4 n1 100 156 180 220 8 19 24
125 184 210 250 8 19 24
150 211 240 285 8 23 26
200 266 295 340 8 23 30
Standard construction
mm
Picture NMS4 kg
DN1 DN2 a fM h1 h2 H m1 m2 n1 n2 n5 w1 b b1 s s1 l1 l2 w m4 m5 g2
NMS4 80/315S 100 80 125 998 250 315 536 160 120 400 315 279 25 80 70 18 15 222 234 312 432 382 6
NMS4 80/400C/B 125 80 125 1003 280 355 566 160 120 435 355 279 25 80 70 18 15 268 269 318 520 435 6 339
NMS4 80/400B/B 125 80 125 1003 280 355 566 160 120 435 355 279 25 80 70 18 15 268 269 318 520 435 6 355
NMS4 80/400A/B 125 80 125 1051 280 355 595 160 120 435 355 318 25 80 83 18 19 268 269 334 540 455 6 413
NMS4 80/400S 125 80 125 1118 280 355 618 160 120 435 355 356 55 80 103 18 19 268 269 380 540 460 8 490
NMS4 100/315A/A 125 100 140 1013 250 315 536 160 120 400 315 279 25 80 70 18 15 230 250 312 432 382 6 308
NMS4 100/400C/A 125 100 140 1018 280 355 566 200 150 500 400 279 25 100 70 22 15 268 280 318 520 435 6 366
NMS4 100/400B/A 125 100 140 1066 280 355 595 200 150 500 400 318 25 100 83 22 19 268 280 334 540 455 6 419
NMS4 100/400A/A 125 100 140 1138 280 355 618 200 150 500 400 356 55 100 103 22 19 268 280 385 540 460 8 506
4 NMS4 125/315C/A 150 125 140 1018 280 355 566 200 150 500 400 279 25 100 70 22 15 247 278 318 520 435 6 331
NMS4 125/315B/A 150 125 140 1018 280 355 566 200 150 500 400 279 25 100 70 22 15 247 278 318 520 435 6 350
NMS4 125/315A/A 150 125 140 1066 280 355 595 200 150 500 400 318 25 100 83 22 19 247 278 334 540 455 6 409
NMS4 125/400C/A 150 125 140 1138 315 400 653 200 150 500 400 356 25 100 103 22 19 280 305 410 540 461 8 524
NMS4 125/400B/A 150 125 140 1198 315 400 653 200 150 500 400 356 25 100 103 22 19 280 305 410 540 461 8 574
NMS4 125/400A/A 150 125 140 1237 315 400 725 200 150 500 400 406 25 100 100 22 24 280 305 454 540 461 8 665
NMS4 150/315D/A 200 150 160 1038 280 400 566 200 150 550 450 279 25 100 70 22 15 260 298 318 520 435 6 349
NMS4 150/315C/A 200 150 160 1038 280 400 566 200 150 550 450 279 25 100 70 22 15 260 298 318 520 435 6 374
NMS4 150/315B/A 200 150 160 1086 280 400 595 200 150 550 450 318 25 100 83 22 19 260 298 334 540 455 6 421
NMS4 150/315A/A 200 150 160 1158 280 400 618 200 150 550 450 356 55 100 103 22 19 260 298 385 540 460 8 501
NMS4 150/400C/A 200 150 160 1218 315 450 653 200 150 550 450 356 25 100 103 22 19 295 328 410 540 461 8 594
NMS4 150/400B/A 200 150 160 1257 315 450 725 200 150 550 450 406 25 100 100 22 24 295 328 454 540 461 8 681
NMS4 150/400A/A 200 150 160 1330 315 450 748 200 150 550 450 457 45 100 100 22 24 295 328 482 625 535 6 845
64
NMS4 EI Close Coupled Centrifugal Pumps
Flanges EN 1092-2
4
DG
AG
fM AS
l1 l2 W DN
DK
4.93.094 DE
a
DN2 mm
Holes
DN DG DK DE W
DN1
h2
H N°
A
32 76 100 140 4 19 18
h1 40 84 110 150 4 19 18
50 99 125 165 4 19 20
g2
65 118 145 185 4 19 20
A 4.93.466.1.EI
m2 s s1 80 132 160 200 8 19 22
m1 b b1
100 156 180 220 8 19 24
w m5 w1 n2 n5
n1 125 184 210 250 8 19 24
m4
150 211 240 285 8 23 26
200 266 295 340 8 23 30
mm
Picture NMS4 EI kg
DN1 DN2 a fM AG AS h1 h2 H m1 m2 n1 n2 n5 w1 b b1 s s1 l1 l2 w m4 m5 g2
NMS4 EI 80/315S 100 80 125 998 350 190 250 315 536 160 120 400 315 279 25 80 70 18 15 222 234 312 432 382 6
NMS4 EI 80/400C/B 125 80 125 1003 350 190 280 355 566 160 120 435 355 279 25 80 70 18 15 268 269 318 520 435 6 374
NMS4 EI 80/400B/B 125 80 125 1003 350 190 280 355 566 160 120 435 355 279 25 80 70 18 15 268 269 318 520 435 6 390
NMS4 EI 80/400A/B 125 80 125 1051 350 190 280 355 595 160 120 435 355 318 25 80 83 18 19 268 269 334 540 455 6 448
NMS4 EI 100/315A/A 125 100 140 1013 350 190 250 315 536 160 120 400 315 279 25 80 70 18 15 230 250 312 432 382 6 343
NMS4 EI 100/400C/A 125 100 140 1018 350 190 280 355 566 200 150 500 400 279 25 100 70 22 15 268 280 318 520 435 6 401
NMS4 EI 100/400B/A 125 100 140 1066 350 190 280 355 595 200 150 500 400 318 25 100 83 22 19 268 280 334 540 455 6 454
4 140 350 190 280 247 278 366
NMS4 EI 125/315C/A 150 125 1018 355 566 200 150 500 400 279 25 100 70 22 15 318 520 435 6
NMS4 EI 125/315B/A 150 125 140 1018 350 190 280 355 566 200 150 500 400 279 25 100 70 22 15 247 278 318 520 435 6 385
NMS4 EI 125/315A/A 150 125 140 1066 350 190 280 355 595 200 150 500 400 318 25 100 83 22 19 247 278 334 540 455 6 444
NMS4 EI 150/315D/A 200 150 160 1038 350 190 280 400 566 200 150 550 450 279 25 100 70 22 15 260 298 318 520 435 6 384
NMS4 EI 150/315C/A 200 150 160 1038 350 190 280 400 566 200 150 550 450 279 25 100 70 22 15 260 298 318 520 435 6 409
NMS4 EI 150/315B/A 200 150 160 1086 350 190 280 400 595 200 150 550 450 318 25 100 83 22 19 260 298 334 540 455 6 456
NMS4 EI 150/315A/A 200 150 160 1158 350 190 280 400 618 200 150 550 450 356 55 100 103 22 19 260 298 385 540 460 8 536
65
B-NM4 Close Coupled Centrifugal Pumps
h2
H
DN1
g1 h1
4.93.098
m2 n3
s b
m1 n2
w n1
mm
DN1 DN2
Picture B-NM4 DN1 kg
a fM h1 h2 H m1 m2 n1 n2 n3 b s l1 l2 w g
ISO 228
B-NM4 25/160AE-BE 56 380 100 160 228 37,5 27,5 190 150 30 38 9,5 102 102 250 10 19-19
1 B-NM4 25/200B/A-C/A G 11/2 G 1 63 400 125 180 253 45 32,5 245 200 49 45 11,5 125 125 250 11 25-23
B-NM4 25/200A/C 63 445 125 180 253 45 32,5 245 200 49 45 11,5 125 125 303 11 29
2 3
fM
fM
a l1 l2
a l1 l2
DN2 DN2
DN2 DN2
A
g2*
h2
DN1
h2
DN1
H
H A
g1
h1
4.93.083.1 h1
n3 4.93.078.1 g2
m2 s b
m1 m2 s s1
n2 h4
m1 b b1
w n1 w m5 w1 n2 n5
m4 n1
Flanges EN 1092-2
Bronze construction B-NM4
B-NM4 kg
DN1 DN2 a fM h1 h2 H h4 m1 m2 n1 n2 n3 n5 w1 b b1 s s1 l1 l2 w m4 m5 g1 g2
Picture DG
B-NM4 32/16A-B 50 32 80 410 132 160 260 - 100 70 240 190 47 - - 50 - 14 - 120 120 255 - - 12 - 38-38
B-NM4 32/20B 410 41
50 32 80 160 180 288 - 100 70 240 190 62 - - 50 - 14 - 140 140 255 - - 12 -
B-NM4 32/20A/A 450 45
2
B-NM4 40/16B-C 410 36,6-34,7 W DN
B-NM4 40/16A/B 65 40 80 450 132 160 260 - 100 70 240 190 47 - - 50 - 14 - 121 121 255 - - 10 - 43
DK
B-NM4 40/20A/B-B/B 65 40 100 495 160 180 298 - 100 70 265 212 62 - - 50 - 14 - 142 142 295 - - 12 - 55-55
B-NM4 4025/C/C 535 318 - 140 54 14 10 156 205 175 73 4.93.094 DE
3 65 40 100 190 225 10 125 95 320 250 15 65 175 175 - 6
B-NM4 4025/A/B-B/C 560 350 - 190 60 12 125 280 250 89-73
B-NM4 50/16A/B-B/B 65 50 100 495 160 180 298 - 100 70 265 212 62 - - 50 - 14 - 126 140 295 - - 12 - 55-55 mm
2 B-NM4 50/20B/C-C/C 505 288 62 310 -
65 50 100 160 200 - 100 70 265 212 - - 50 - 14 - 140 153 - - 14 -
B-NM4 50/20A/C 528 320 60 279 -
B-NM4 5025/C/C-D/B 79,5 Holes
3 65 50 100 560 190 225 350 10 125 95 320 250 - 190 15 65 60 14 12 175 175 125 280 250 - 6 DN DG DK DE W
B-NM4 5025/A/B-B/B 105-92
B-NM4 65/16A/C-B/C-C/C 495 306 62 300 60-57-66
80 65 100 160 200 - 125 95 280 212 - - 65 - 14 - 140 161 - - 12 - N°
B-NM4 65/16S/A 528 320 60 279 69,8
B-NM4 65/20A/A-B/A 80 65 100 528 180 225 340 - 125 95 320 250 60 - - 65 - 14 - 159 179 279 - - 12 - - 32 76 100 140 4 19 18
66
B-NMS4 Close Coupled Centrifugal Pumps
DG
4
W DN
fM DK
a l1 l2
DE
DN2 DN2 4.93.094
mm
DN1
h2 Holes
DN DG DK DE W
H A
N°
h1 32 76 100 140 4 19 18
40 84 110 150 4 19 18
g2
4.93.466.1 50 99 125 165 4 19 20
A
m2 s s1 65 118 145 185 4 19 20
m1 b b1 80 132 160 200 8 19 22
w m5 w1 n2 n5
100 156 180 220 8 19 24
m4 n1
125 184 210 250 8 19 24
150 211 240 285 8 23 26
Bronze construction B-NM4 200 266 295 340 8 23 30
mm
Picture B-NMS4 kg
DN1 DN2 a fM h1 h2 H m1 m2 n1 n2 n5 w1 b b1 s s1 l1 l2 w m4 m5 g2
BNMS4 80/250A/A-B/A 100 80 125 807 200 280 387 160 120 400 315 216 20 80 69 18 12 191 210 322 298 258 6 181-171
BNMS4 80/315B/B 100 80 125 948 250 315 457 160 120 400 315 254 20 80 60 18 15 222 234 271 435 395 6
BNMS4 80/315A/B 100 80 125 948 250 315 457 160 120 400 315 254 20 80 60 18 15 222 234 271 435 395 6
BNMS4 80/315S 100 80 125 998 250 315 536 160 120 400 315 279 25 80 70 18 15 222 234 312 432 382 6
BNMS4 80/400C/B 125 80 125 1003 280 355 566 160 120 435 355 279 25 80 70 18 15 268 269 318 520 435 6
BNMS4 80/400B/B 125 80 125 1003 280 355 566 160 120 435 355 279 25 80 70 18 15 268 269 318 520 435 6
BNMS4 80/400A/B 125 80 125 1051 280 355 595 160 120 435 355 318 25 80 83 18 19 268 269 334 540 455 6
BNMS4 80/400S 125 80 125 1118 280 355 618 160 120 435 355 356 55 80 103 18 19 268 269 380 540 460 8
BNMS4 100/250B/A 125 100 140 822 225 280 412 160 120 400 315 216 20 80 69 18 12 205 233 322 298 258 6 192
BNMS4 100/250A/A 125 100 140 872 225 280 412 160 120 400 315 216 20 80 69 18 12 205 233 322 298 258 6 206
BNMS4 100/315C/A 125 100 140 966 250 315 457 160 120 400 315 254 20 80 60 18 15 230 250 274 435 395 6 284
BNMS4 100/315B/A 125 100 140 966 250 315 457 160 120 400 315 254 20 80 60 18 15 230 250 274 435 395 6 300
BNMS4 100/315A/A 125 100 140 1013 250 315 536 160 120 400 315 279 25 80 70 18 15 230 250 312 432 382 6
BNMS4 100/400C/A 125 100 140 1018 280 355 566 200 150 500 400 279 25 100 70 22 15 268 280 318 520 435 6
BNMS4 100/400B/A 125 100 140 1066 280 355 595 200 150 500 400 318 25 100 83 22 19 268 280 334 540 455 6
BNMS4 100/400A/A 125 100 140 1138 280 355 618 200 150 500 400 356 55 100 103 22 19 268 280 385 540 460 8
4 BNMS4 125/250D/A-E/A 150 125 140 822 250 355 437 160 120 400 315 216 20 80 69 18 12 235 268 322 298 258 6
BNMS4 125/250C/A 150 125 140 872 250 355 437 160 120 400 315 216 20 80 69 18 12 235 268 322 298 258 6
BNMS4 125/250B/A 150 125 140 951 250 355 457 160 120 400 315 254 20 80 60 18 15 235 268 259 435 395 6 265
BNMS4 125/250A/A 150 125 140 951 250 355 457 160 120 400 315 254 20 80 60 18 15 235 268 259 435 395 6 273
BNMS4 125/315C/A 150 125 140 1018 280 355 566 200 150 500 400 279 25 100 70 22 15 247 278 318 520 435 6 383
BNMS4 125/315B/A 150 125 140 1018 280 355 566 200 150 500 400 279 25 100 70 22 15 247 278 318 520 435 6 395
BNMS4 125/315A/A 150 125 140 1066 280 355 595 200 150 500 400 318 25 100 83 22 19 247 278 334 540 455 6
BNMS4 125/400C/A 150 125 140 1138 315 400 653 200 150 500 400 356 25 100 103 22 19 280 305 410 540 461 8
BNMS4 125/400B/A 150 125 140 1198 315 400 653 200 150 500 400 356 25 100 103 22 19 280 305 410 540 461 8
BNMS4 125/400A/A 150 125 140 1237 315 400 725 200 150 500 400 406 25 100 100 22 24 280 305 454 540 461 8
BNMS4 150/315D/A 200 150 160 1038 280 400 566 200 150 550 450 279 25 100 70 22 15 260 298 318 520 435 6 380
BNMS4 150/315C/A 200 150 160 1038 280 400 566 200 150 550 450 279 25 100 70 22 15 260 298 318 520 435 6 395
BNMS4 150/315B/A 200 150 160 1086 280 400 595 200 150 550 450 318 25 100 83 22 19 260 298 334 540 455 6 467
BNMS4 150/315A/A 200 150 160 1158 280 400 618 200 150 550 450 356 55 100 103 22 19 260 298 385 540 460 8 544
BNMS4 150/400C/A 200 150 160 1218 315 450 653 200 150 550 450 356 25 100 103 22 19 295 328 410 540 461 8
BNMS4 150/400B/A 200 150 160 1257 315 450 725 200 150 550 450 406 25 100 100 22 24 295 328 454 540 461 8
BNMS4 150/400A/A 200 150 160 1330 315 450 748 200 150 550 450 457 45 100 100 22 24 295 328 482 625 535 6
67
NM4, NMS4 Close Coupled Centrifugal Pumps
Features
NM4S
Flexible
The option to choose between cast iron and bronze mate-
rias for the hydraulic parts in contact with the pumped
liquid allows NM4 series pumps to be selected for use with
different types of liquids.
Compact Design
The compact design allows for easy installtion even in
confined spaces.
Exclusive design
An innovative, patented guard prevents contact with rota-
ting parts, proving protection to the end user whilst
allowing for inspection of the mechanical seal.
Reliable
The bearing and shaft are designed to ensure the reduc-
tion of the stress, providing high reliability under all opera-
ting conditions.
NMS
Cutting edge hydraulics
The geometry of the impeller and the pump casing are
optimized to achieve maximum efficiency and the best
suction capability.
Flexibility
The option to choose between cast iron and bronze mate-
rias for the hydraulic parts in contact with the pumped
liquid allows NMS4 series pumps to be selected for use
with different types of liquids.
Exclusive design
An innovative, patented guard prevents contact with rota-
ting parts, proving protection to the end user whilst
allowing for inspection of the mechanical seal.
68
03/2021
Construction
Single-stage end-suction centrifugal pumps, with bearing
bracket.
Nominal duty points and main dimensions in accordance with
EN 733. Back Pull-Out construction, for simple and quick
dismantling and reassembly.
N, N4: version with pump casing and lantern bracket in cast iron.
B-N, B-N4: version with pump casing and lantern bracket in bronze.
(the pumps are supplied fully painted).
Applications
For clean liquids, without abrasives, which are non-aggressive
for the pump materials (contents of solids up to 0.2%).
For water supply.
For heating, air conditioning, cooling and circulation plants.
For civil and industrial applications and for agriculture.
For fire fighting applications.
For irrigation.
Operating conditions
Liquid temperature from -10 °C to +90 °C.
Ambient temperature up to 40 °C.
Total suction lift up to 7 m.
Maximum permissible working pressure up to 10 bar (16 bar for
N 32L-160,200; N,N4 40-160,200; N,N4 50-125,160; N,N4 65-
125,160,200,250; N,N4 80-160,200,250,315,400; N,N4 100-200).
Maximum permissible rotation speed: see table on page 90.
The electropumps N, B-N, N4, B-N4 series comply with the European Pump-Motor unit
Regulation no. 547/2012. N,N4 pump connected to a standard electric motor in B3
construction form (EN 60072-1), by means of a baseplate,
driven by a flexible coupling and with coupling protection.
Materials Three-phase 400 V , 50 Hz
Components N, N4 B-N, B-N4 N, N4 Classification scheme IE3 for three-phase motors from 0,75 kW.
Mechanical seal Mechanical seal Stuffing box IP 55 protection.
Pump casing Cast iron Bronze Cast iron Motor suitable for operation with frequency converter.
Casing cover GJL 200 EN 1561 G-Cu Sn 10 EN 1982 GJL 200 EN 1561
Impeller Cast iron Bronze Cast iron
GJL 200 EN 1561 G-Cu Sn 10 EN 1982 GJL 200 EN 1561
Brass P- Cu Zn 40 Pb 2 UNI 5705
Special features on request
For 32-125, 32-160, 32-200, 32L-200, 40-200 - Special mechanical seal.
- Chrome-nickel steel AISI 316 pump-shaft.
Shaft Chrome steel Cr-Ni-Mo steel Carbon steel - Higher or lower liquid or ambient temperatures.
1.4104 EN 10088 1.4401 EN 10088
(AISI 430) (AISI 316) C 40 UNI 7845 - Other motor protection.
- Motor for other voltage.
Shaft sleeve Bronze
_ _ G-Cu Sn5 Zn5 Pb5 EN 1982 - Frequency 60 Hz (as per 60 Hz data sheet).
with chromate surface
Mechanical seal Carbon - Ceramic - NBR _
Counter-flanges Steel Fe 430B UNI 7070
69
N End-Suction Centrifugal Pumps
standardized EN 733
20
5
5 6 7 8 9 10 m 3/h 20 30 40 50 100 200 300 400 500
Q l/min
100 150 300 400 500 1000 2000 3000 4000 5000 8000
72.844.N
Tolerances according to UNI EN ISO 9906:2012
B-N 32-125S/A N 32-125S/A 90 S2 1,5 23,5 23,5 23 22,5 22 21,5 21 20,5 19 18,5 16,5 13
0,86 0,9 0,94 1 1,06 1,12 1,17 1,25 1,3 1,36 1,42 1,49
B-N 32-160B/A N 32-160B/A 90 S2 1,5 29,5 29,5 29 28,5 27,5 27 26 25* 22,5* 20* 17,5* 12,5*
90 L2 2,2 1,1 1,17 1,23 1,30 1,37 1,43 1,48 1,55 1,63 1,7 1,75 1,79
B-N 32-160A/A N 32-160A/A 90 L2 2,2 35,5 35,5 35 34,5 34 33,5 33 32* 30* 28* 25* 21* 15*
100 L2 3 1,56 1,64 1,71 1,81 1,9 1,98 2,05 2,16 2,24 2,33 2,4 2,47 2,5
B-N 32-200D/A N 32-200D/A 90 L2 2,2 Hm 37,5 37 36 35 34 33 32 30 27 22
100 L2 3 1,92 2 2,06 2,17 2,24 2,3 2,35 2,4 2,45 2,5
P3 kW
B-N 32-200C/A N 32-200C/A 100 L2 3 44,5 44 43,5 43 42 41 40 38,5 36 32
2,17 2,28 2,36 2,5 2,63 2,74 2,83 2,97 3,1 3,2
B-N 32-200A/A N 32-200A/A 112 M2 4 57 56,5 56 55,5 54,5 53,5 52,5 51 49 46
132 S2 5,5 2,9 3,1 3,18 3,35 3,51 3,67 3,8 4 4,2 4,4
25,1 24,9 24,7 24,4 23,8 23 21,8 20,3 17,3 13,4
B-N 32L-160C N 32L-160C 90 L2 2,2 1,25 1,35 1,4 1,45 1,55 1,65 1,75 1,85 1,95 2,05
30,4 30,3 30,2 30 29,6 29 28,1 26,8 24,2 20,8 17,9
B-N 32L-160B N 32L-160B 100 L2 3 1,85 1,95 2 2,1 2,2 2,35 2,45 2,55 2,7 2,85 2,9
112 M2 39,9 39,9 39,8 39,6 39,3 38,8 37,9 36,8 34,7 31,9 29,7 25,6
B-N 32L-160A N 32L-160A 4 2,35 2,5 2,6 2,7 2,85 3 3,2 3,35 3,6 3,8 3,9 4,05
B-N 32L-200C N 32L-200C 112 M2 4 42,1 41,8 41,5 41 40,2 38,9 37 34,5 29,7 23,8
2,5 2,65 2,8 2,9 3,1 3,25 3,45 3,6 3,8 4
132 S2 5,5 51,7 51,6 51,4 51,2 50,7 50 48,8 47 43,2 37,8 33,5
B-N 32L-200B N 32L-200B 3,15 3,3 3,45 3,6 3,85 4,1 4,35 4,55 4,9 5,15 5,35
7,5 59,4 59,4 59,4 59,4 59,2 58,8 58 56,6 53,4 48,6 44,6 37,7
B-N 32L-200A N 32L-200A 132 S2 3,8 4 4,2 4,35 4,65 4,9 5,25 5,5 5,9 6,3 6,5 6,8
B-N 40-125C/A N 40-125C/A 90 S2 1,5 17,5 17 16,5 16 15 13,5 12 10,5 7,5 6,5
1,21 1,26 1,32 1,38 1,44 1,49 1,53 1,56 1,57 1,57
22 22 21,5 21 20 19 18 16,5 14 13 11,5
B-N 40-125A/A N 40-125A/A 90 L2 2,2 1,50 1,57 1,65 1,72 1,82 1,91 1,98 2,04 2,10 2,11 2,13
23 22,5 22 21,5 20 18,5 16,5 14,5 11 10
B-N 40-160C/A N 40-160C/A 90 L2 2,2 1,55 1,63 1,72 1,80 1,90 1,99 2,06 2,12 2,17 2,17
B-N 40-200B/A N 40-200B/A 132 S2 5,5 50 49,5 48,5 47,5 45,5 43,5 41,5 37,5 30,5
132 S2 7,5 3,96 4,18 4,41 4,64 4,92 5,17 5,39 5,60 5,87
B-N 40-200AR/A N 40-200AR/A 132 S2 5,5 55 54,5 54 53 51 49
132 S2 7,5 4,50 4,70 5,07 5,30 5,65 5,95
57,5 57 56,5 55,5 54,5 52,5 50,5 48 42,5 40,5 35
B-N 40-200A/A N 40-200A/A 132 S2 7,5 4,78 5,04 5,34 5,63 6,03 6,40 6,70 7,01 7,34 7,43 7,62
61 61 60,5 59,5 58,5 56,5 53,5 49,5 41,5 40 33,5
B-N 40-250C/A N 40-250C/A 160 M2 11 5,86 6,16 6,49 6,82 7,28 7,72 8,07 8,48 9,02 9,15 9,35
69,5 69,5 69 68,5 67 65,5 63,5 60,5 53,5 51 45
B-N 40-250B/A N 40-250B/A 160 M2 11 6,87 7,19 7,56 7,91 8,47 8,91 9,35 9,75 10,40 10,54 10,93
90 90 89,5 89 88,5 87 85 83 77,5 76 70,5
B-N 40-250A/A N 40-250A/A 160 M2 15 9,31 9,73 10,21 10,68 11,34 11,98 12,60 13,19 14,00 14,21 14,65
N Standard construction. P2 Rated motor power output. P3 Pump power input. H Total head in m. * Maximum suction lift 1-2 m.
B-N Bronze construction.
70
N End-Suction Centrifugal Pumps
standardized EN 733
B-N 50-160B/A N 50-160B/A 132 S2 5,5 31 30,5 29,5 28 26 24 21,5 19 17,5 15,5 13,5 11,5 9,5
4,30 4,48 4,71 4,90 5,11 5,28 5,35 5,40 5,40 5,36 5,32 5,30 5,22
B-N 50-160A/A N 50-160A/A 132 S2 7,5 38,5 38 37,5 36,5 34,5 32,5 30 27 25,5 24 22,5 20,5 19
5,44 5,67 6,02 6,31 6,67 6,95 7,18 7,30 7,34 7,38 7,41 7,42 7,46
Hm 48 47,5 47,5 47 45,5 44,5 42,5 40 37 33 30,5 28 25,5 23
B-N 50-200B/A N 50-200B/A 160 M2 11 5,81 6,13 6,44 6,73 7,18 7,55 8,02 8,43 8,77 9,01 9,08 9,15 9,19 9,23
P3 kW
B-N 50-200A/A N 50-200A/A 160 M2 11 55 55 54,5 54,5 53,5 52 50 48 45 41,5 39,5 37 35 32,5
6,92 7,29 7,65 7,99 8,56 8,99 9,57 10,05 10,45 10,75 10,89 10,98 11,11 11,15
B-N 50-200S/A N 50-200S/A 160 M2 15 60 60 59,5 59,5 58,5 57,5 55,5 53,5 50,5 47 45 43 40,5 37
7,56 7,98 8,39 8,79 9,38 9,82 10,48 11,05 11,54 11,85 12,02 12,20 12,30 12,40
B-N 50-250C/A N 50-250C/A 160 M2 11 55 54,5 54 53 51,5 49,5 46,0 41,5 35,5 28,5 24,5
7,28 7,68 8,06 8,42 8,98 9,42 9,99 10,42 10,75 10,95 11,08
B-N 50-250A/A N 50-250A/A 160 L2 18,5 80,5 80,5 80 79,5 78,5 77 74,5 71,5 67 61,5 58,5
11,75 12,33 12,92 13,56 14,47 15,20 16,10 16,94 17,65 18,25 18,55
POMPA
PUMP POMPA
PUMP Q m3/h 24 27 30 33 37,8 42 48 54 60 66 75 84 96 108 120 132 141
MOTORE
MOTOR P2
B-N N kW Q l/min 400 450 500 550 630 700 800 900 1000 1100 1250 1400 1600 1800 2000 2200 2350
B-N 65-125E/B N 65-125E/B 112 M2 4 16,5 16,4 16,2 15,9 15,5 15,1 14,3 13,2 11,4 9,2
2,86 2,99 3,17 3,34 3,5 3,64 3,81 3,94 4,03 4
5,5 21,1 21 20,8 20,6 20,3 19,9 19,1 18,2 16,5 14,4 11,8
B-N 65-125C/B N 65-125C/B 132 S2 3,68 3,86 4,11 4,35 4,57 4,77 5,02 5,23 5,41 5,5 5,49
B-N 65-125A/B 132 S2 7,5 25,9 25,8 25,6 25,4 25,1 24,8 24,1 23,3 21,9 20 17,6
N 65-125A/B 4,71 4,92 5,21 5,5 5,77 6,03 6,38 6,69 7,02 7,25 7,36
B-N 65-160D/B N 65-160D/B 132 S2 7,5 24,3 24,1 23,9 23,6 23,1 22,3 20,8 18,8 16,3
5,11 5,44 5,75 6,05 6,45 6,8 7,15 7,4 7,52
B-N 65-160C/B N 65-160C/B 160 M2 28,1 28 27,8 27,6 27,1 26,3 24,9 23,1 20,7 17,7
11 5,89 6,26 6,61 6,96 7,44 7,87 8,37 8,74 8,98 9,06
B-N 65-160B/B N 65-160B/B 160 M2 32,6 32,5 32,3 32 31,5 30,8 29,5 27,9 25,7 23,0
11 Hm 7,04 7,44 7,84 8,22 8,76 9,25 9,84 10,33 10,7 10,96
36,4 36,3 36,2 35,9 35,5 34,8 33,7 32,1 30,0 27,5
B-N 65-160AR N 65-160AR 160 M2 15 P3 kW 7,98 8,45 8,91 9,36 9,99 10,57 11,27 11,85 12,33 12,71
B-N 65-160A/B N 65-160A/B 160 M2 40,5 40,4 40,2 40 39,5 38,8 37,6 36,1 34,2 31,7
15 8,91 9,44 9,96 10,47 11,19 11,85 12,64 13,33 13,92 14,42
B-N 65-200C/B N 65-200C/B 160 M2 44 43,8 43,5 43,1 42,3 41,2 39,4 37,1 34,4 31,4 28,8
15 9,2 9,8 10,4 10,9 11,7 12,3 13,1 13,8 14,3 14,8 15,1
B-N 65-200B/B N 65-200B/B 160 L2 18,5 50,5 50,4 50,2 49,9 49,2 48,3 46,8 44,8 42,5 39,8 37,5
10,9 11,5 12,2 12,8 13,7 14,6 15,6 16,4 17,2 17,9 18,3
B-N 65-200A/B N 65-200A/B 180 M2 22 57 57 57 56,5 56 55,5 54 52,5 50 47,5 45,5
13,3 14,1 14,9 15,6 16,7 17,7 19 20,1 21,1 22 22,5
B-N 65-250C/B N 65-250C/B 180 M2 22 61 61 60,5 60 58,5 57 54,5 51,5 47,5 43
13,5 14,5 15 16 17 18 19 20 21 21,5
B-N 65-250B/B N 65-250B/B 200 L2 30 73,5 73,5 73,5 73,5 73 71,5 69,5 66,5 63 59
18,5 19,5 20,5 21,5 23 24,5 26 27,5 29 30,5
B-N 65-250A/B N 65-250A/B 200 L2 37 86,5 86,5 87 86,5 86 85,5 83,5 81 78 74,5
22 23,5 24,5 26 27,5 29,5 31,5 34 35,5 37
PUMP
POMPA PUMP
POMPA Q m3/h 60 66 75 84 96 108 120 132 150 168 180 192 210 240 270 300
MOTOR
MOTORE P2
B-N N kW Q l/min 1000 1100 1250 1400 1600 1800 2000 2200 2500 2800 3000 3200 3500 4000 4500 5000
21,5 20,9 19,9 18,7 17,4 15,9 13,4 10,6
B-N 80-160E/B N 80-160E/B 132 S2 7,5 6,81 6,92 7,05 7,15 7,22 7,26 7,27 7,21
B-N 80-160D/B N 80-160D/B 160 M2 11 25,2 24,5 23,5 22,4 21,1 19,6 17,2 14,4
8 8,22 8,49 8,73 8,93 9,09 9,23 9,23
B-N 80-160C/B N 80-160C/B 160 M2 11 28,7 28,2 27,4 26,4 25,1 23,8 21,3 18,5 16,4
9,04 9,35 9,74 10,09 10,39 10,65 10,91 10,99 10,93
B-N 80-160B/B N 80-160B/B 160 M2 15 34,8 34,5 33,8 33 32,1 30,9 28,9 26,4 24,5 22,4
11,37 11,83 12,42 13 13,53 14,01 14,63 15,07 15,26 15,34
B-N 80-160A/B N 80-160A/B 160 L2 18,5 39,9 39,6 39 38,2 37,4 36,4 34,5 32,2 30,3 28,1
13,25 13,82 14,58 15,3 15,99 16,62 17,45 18,09 18,4 18,59
B-N 80-200B/A N 80-200B/A 180 M2 22 46,5 46 45,5 44,5 43,5 42 39* 35,5* 32*
15,7 16,6 17,7 18,6 19,4 20,2 21,3 21,8 22
B-N 80-250E/A N 80-250E/A 180 M2 22 51 50 48,5 46,5 44,5 42 38* 33* 29*
16,2 17,1 18,2 19,1 20 20,6 21,4 21,9 22
Hm 65 64 62,5 61 59 56,5 53* 49* 45,5* 41*
B-N 80-250D/A N 80-250D/A 200 L2 30 21,3 22,3 24 25,3 26,5 27,5 28,6 29,8 30
29,4
P3 kW 73,5 73 72 70,5 69 67 63* 59* 55,5* 51,5*
B-N 80-250C/A N 80-250C/A 200 L2 37 24,6 26 27,8 29,5 31 32,4 33,8 35,2 35,7 36,2
84 83,5 82,5 81,5 80 78 74,5* 70,5* 67* 63*
B-N 80-250B/A N 80-250B/A 225 M2 45 29 30,7 32,9 35 36,7 38,3 40,1 41,8 43 44,1
N Standard construction. P2 Rated motor power output. H Total head in m. * Maximum suction lift 1-2 m. ° Minimum positive suction head 1 m.
B-N Bronze construction. P3 Pump power input.
71
N4 End-Suction Centrifugal Pumps
standardized EN 733
10 U.S. g.p.m. 20 30 40 50 100 200 300 400 500 1000 2000 3000
70
60 200
50
N4 80-400 N4 N4 H
40 100-400 125-400 N4 ft
150-400
30 100
N4 65-315 N4
80-315 N4
N4 100-315 125-315
20
N4 40-250 N4
N4 65-250 N4 150-315
H N4 50-250 80-250 N4 50
100-250
m
N4 40
N4 32-200 N4 40-200 N4
10 65-200 N4 125-250
N4 50-200
80-200 N4 30
100-200
N4 32-160 N4 40-160 N4 50-160 N4
65-160 N4 20
80-160
5
4 N4 50-125 N4
N4 32-125 65-125
3 10
7
2
2 m 3/h 5 10 20 30 40 50 100 200 300 400 500 700
Q l/min
40 50 100 150 200 300 400 500 1000 2000 3000 4000 5000 10000
72.842.C
B-N4 32-125F/A N4 32-125F/A 71 M4 0,25 3,6 3,6 3,5 3,5 3,4 3,2 3 2,8 2,4 1,9 1,1
0,07 0,075 0,08 0,09 0,095 0,1 0,1 0,105 0,11 0,115 0,115
4,7 4,7 4,7 4,7 4,6 4,6 4,5 4,3 4,1 3,8 3,3 2,6
B-N4 32-125D/A N4 32-125D/A 71 M4 0,25 0,095 0,075 0,11 0,115 0,125 0,13 0,135 0,145 0,15 0,155 0,165 0,17
B-N4 32-125A/A N4 32-125A/A 71 M4 5,7 5,8 5,8 5,7 5,7 5,7 5,6 5,5 5,4 5,2 4,8 4,3
0,25
Hm 0,12 0,1 0,135 0,145 0,15 0,16 0,165 0,175 0,185 0,195 0,205 0,215
0,37 7,6 7,5 7,4 7,3 7,2 7,1 6,9 6,7 6,3 5,9 5,2 4,2
B-N4 32-160B/A N4 32-160B/A 71 M4 0,13 0,125 0,15 0,16 0,17 0,18 0,19 0,2 0,21 0,215 0,23 0,235
P3 kW
9 8,95 8,9 8,8 8,7 8,6 8,5 8,3 7,9 7,5 6,8 6 5,1
B-N4 32-160A/A N4 32-160A/A 71 M4 0,37 0,17 0,18 0,19 0,2 0,21 0,22 0,23 0,24 0,26 0,275 0,29 0,305 0,315
12,5 12,4 12,3 12,2 12 11,8 11,6 11,2 10,6 10 8,9 7,6 6,2 4,7
B-N4 32-200B/A N4 32-200B/A 80 M4 0,55 0,28 0,3 0,315 0,33 0,345 0,36 0,375 0,39 0,41 0,43 0,455 0,48 0,5 0,515
14,3 14,2 14,1 14 13,9 13,7 13,5 13,3 12,9 12,3 11,3 10,2 8,9 7,5
B-N4 32-200A/A N4 32-200A/A 80 M4 0,75 0,35 0,375 0,4 0,42 0,44 0,46 0,48 0,5 0,525 0,55 0,585 0,61 0,635 0,655
Q m3/h 5,4 6 6,6 7,5 8,4 9,6 10,8 12 13,2 15 16,8 18,9 21 24 27 30
PUMP
POMPA PUMP
POMPA MOTOR
MOTORE P2
kW Q l/min 90 100 110 125 140 160 180 200 220 250 280 315 350 400 450 500
6,1 6 5,9 5,9 5,8 5,6 5,4 5,2 5 4,5 3,9 3,1 2,3
B-N4 40-160C/A N4 40-160C/A 71 M4 0,37 0,17 0,18 0,19 0,2 0,21 0,23 0,24 0,25 0,26 0,27 0,28 0,29 0,3
7,6 7,6 7,6 7,6 7,6 7,3 7,1 6,9 6,6 6,3 5,7 5 4 2,7
B-N4 40-160B/A N4 40-160B/A 80 M4 0,55 0,22 0,23 0,24 0,26 0,27 0,29 0,31 0,32 0,34 0,36 0,38 0,39 0,4 0,41
9,6 9,6 9,6 9,6 9,4 9,3 9,1 9 8,8 8,4 7,9 7,2 6,4 5,1 3,5
B-N4 40-160A/A N4 40-160A/A 80 M4 0,75 0,28 0,3 0,31 0,33 0,35 0,37 0,4 0,42 0,44 0,47 0,49 0,51 0,53 0,55 0,56
Hm 13 12,9 12,8 12,7 12,6 12,4 12,2 12 11,5 10,8 10 8,6 7
B-N4 40-200B/A N4 40-200B/A 90 S4 1,1 0,51 0,53 0,54 0,57 0,60 0,63 0,66 0,68 0,71 0,75 0,78 0,81 0,83
P3 kW
B-N4 40-200A/A N4 40-200A/A 90 S4 14,8 14,7 14,6 14,5 14,4 14,2 14 13,8 13,6 13 12,2 11,3 10
1,1 0,59 0,6 0,61 0,64 0,67 0,71 0,74 0,77 0,8 0,85 0,9 0,94 0,97
B-N4 40-250C/A N4 40-250C/A 90 L4 1,5 17,4 17,3 17,2 17,2 17 16,8 16,6 16,3 16 15,1 13,8 12,1 10,4 7,2 2,8
0,689 0,715 0,74 0,779 0,817 0,865 0,912 0,967 1,018 1,092 1,134 1,178 1,248 1,301 1,348
B-N4 40-250B/A N4 40-250B/A 100 LA4 2,2 21,4 21,5 21,4 21,3 21,2 21 20,9 20,8 20,5 20 19,5 18,3 16,4 13,3 10 5
0,908 0,942 0,99 1,025 1,075 1,140 1,203 1,266 1,327 1,405 1,482 1,567 1,645 1,752 1,815 1,887
B-N4 40-250A/A N4 40-250A/A 100 LB4 3 22,9 22,8 22,9 22,9 22,8 22,5 22,5 22,2 22 21,8 21,4 20,4 18,9 16 12,6 8
1,068 1,104 1,15 1,193 1,246 1,316 1,385 1,454 1,521 1,638 1,733 1,817 1,933 2,068 2,168 2,267
N4 Standard construction. P2 Rated motor power output. H Total head in m. * Maximum suction lift 1-2 m.
B-N4 Bronze construction. P3 Pump power input.
72
N4 End-Suction Centrifugal Pumps
standardized EN 733
B-N4 50-125F/A N4 50-125F/A 71 M4 0,37 4,5 4,5 4,4 4,3 4,1 3,8 3,5 2,9 2,2 1,4 0,5
0,26 0,275 0,285 0,3 0,31 0,32 0,325 0,33 0,325 0,315 0,3
B-N4 50-125D/A N4 50-125D/A 80 M4 0,55 5,5 5,5 5,4 5,4 5,2 5,1 4,8 4,4 3,8 3,2 2,5
0,32 0,335 0,345 0,365 0,385 0,4 0,415 0,425 0,435 0,43 0,425
B-N4 50-125A/A N4 50-125A/A 80 M4 0,75 6,4 6,4 6,3 6,3 6,2 6,1 5,9 5,6 5,2 4,6 4 2,9
0,37 0,39 0,405 0,425 0,45 0,47 0,49 0,51 0,525 0,535 0,535 0,525
B-N4 50-125S/A N4 50-125S/A 80 M4 0,75 6,8 6,8 6,8 6,8 6,7 6,6 6,4 6,2 5,8 5,3 4,8 3,8
0,4 0,42 0,435 0,46 0,48 0,505 0,525 0,555 0,57 0,585 0,59 0,59
B-N4 50-160B/A N4 50-160B/A 90 S4 1,1 8,2 8,2 8,2 8,1 8 7,8 7,6 7,2 6,7 6,2 5,5 4,4 3,3
0,449 0,469 0,496 0,524 0,555 0,584 0,610 0,643 0,671 0,683 0,692 0,687 0,673
B-N4 50-160A/A N4 50-160A/A 90 S4 1,1 9,6 9,6 9,6 9,5 9,5 9,3 9,1 8,8 8,3 7,8 7,2 6,1 4,9 3,1
Hm 0,555 0,578 0,600 0,632 0,670 0,705 0,742 0,778 0,811 0,833 0,850 0,862 0,861 0,844
11,8 11,8 11,7 11,7 11,5 11,3 10,9 10,4 9,8 9 8,1 6,3 4,7
B-N4 50-200C/A N4 50-200C/A 90 S4 1,1 P3 kW 0,617 0,647 0,682 0,720 0,759 0,801 0,841 0,888 0,927 0,957 0,979 1,005 1,010
90 L4 13,4 13,4 13,4 13,3 13,1 12,9 12,6 12,1 11,5 10,8 9,9 8,2 6,4 3,7
B-N4 50-200B/A N4 50-200B/A 1,5 0,772 0,807 0,840 0,889 0,949 0,998 1,051 1,115 1,171 1,213 1,251 1,278 1,299 1,301
B-N4 50-200A/A N4 50-200A/A 100 L4 14,9 14,9 14,9 14,9 14,8 14,6 14,4 14 13,4 12,8 12 10,4 8,6 6
2,2 0,883 0,923 0,962 1,019 1,074 1,135 1,194 1,273 1,345 1,409 1,464 1,535 1,576 1,596
B-N4 50-250D/A N4 50-250D/A 100 L4 2,2 14,5 14,4 14,3 14 13,7 13,4 13 12,2 11,2 9,7 8,1 5,4 2,3
0,843 0,886 0,929 0,990 1,049 1,098 1,160 1,230 1,300 1,364 1,395 1,435 1,468
B-N4 50-250C/A N4 50-250C/A 100 L4 2,2 17,8 17,8 17,7 17,5 17,2 16,8 16,4 15,7 14,9 13,8 12,4 9,7 6,8
1,091 1,140 1,188 1,258 1,324 1,397 1,465 1,554 1,633 1,700 1,755 1,818 1,844
B-N4 50-250B/A N4 50-250B/A 100 L4 3 20,7 20,7 20,7 20,6 20,4 20 19,5 18,9 18,2 17,1 15,9 13,2 10,6 5,8
1,374 1,437 1,499 1,591 1,680 1,781 1,878 2,009 2,130 2,241 2,320 2,448 2,510 2,580
B-N4 50-250A/A N4 50-250A/A 112 M4 4 22,7 22,7 22,6 22,5 22,4 22,1 21,6 21 20,2 19,4 18,3 16,4 13,6 9
1,493 1,561 1,628 1,728 1,825 1,935 2,042 2,186 2,322 2,445 2,557 2,706 2,804 2,893
POMPA
PUMP POMPA
PUMP Q m3/h 21 24 27 30 33 37,8 42 48 54 60 66 75 84 96 108 120
MOTORE
MOTOR P2
B-N4 N4 kW Q l/min 350 400 450 500 550 630 700 800 900 1000 1100 1250 1400 1600 1800 2000
5,5 25,8 25,7 25,5 25,3 25 24,4 23,8 22,8 21,5 20 18,2 15 11
B-N4 65-315C/A N4 65-315C/A 132 S4 3,12 3,31 3,49 3,67 3,83 4,05 4,25 4,5 4,75 4,96 5,12 5,3 5,44
7,5 31 31 30,9 30,8 30,6 30,2 29,7 28,8 27,8 26,5 25 22,2 18,6
B-N4 65-315B/A N4 65-315B/A 132 M4 3,97 4,23 4,45 4,65 4,85 5,15 5,4 5,75 6,1 6,4 6,65 7 7,2
B-N4 65-315A/A N4 65-315A/A 160 M4 11 35,9 35,9 35,8 35,7 35,5 35,1 34,6 33,8 32,8 31,6 30,2 27,8 25
4,8 5,1 5,4 5,6 5,8 6,15 6,5 6,9 7,3 7,6 7,9 8,3 8,7
POMPA
PUMP POMPA
PUMP Q m3/h 30 33 37,8 42 48 54 60 66 75 84 96 108 120 132 150 168 180
MOTOR
MOTORE P2
B-N4 N4 kW Q l/min 500 550 630 700 800 900 1000 1100 1250 1400 1600 1800 2000 2200 2500 2800 3000
1,1 6,1 6,1 5,9 5,8 5,5 5,2 4,9 4,6 4 3,3
B-N4 80-160C/B N4 80-160C/B 90 S4 0,87 0,88 0,9 0,92 0,95 0,98 1 1,02 1,03 1,04
1,5 7,8 7,7 7,6 7,5 7,3 7 6,8 6,4 5,9 5,2 4,1
B-N4 80-160B/B N4 80-160B/B 90 L4 1,14 1,16 1,2 1,23 1,27 1,31 1,34 1,37 1,41 1,44 1,46
10 10 9,9 9,8 9,7 9,5 9,3 9 8,5 8 7 5,9
B-N4 80-160A/B N4 80-160A/B 100 L4 2,2 1,49 1,53 1,6 1,66 1,74 1,82 1,9 1,97 2,07 2,15 2,22 2,24
10,3 10,2 10,1 10 9,8 9,5 9,1 8,6 7,7 6,6 4,6
B-N4 80-200C/A N4 80-200C/A 100 L4 2,2 1,56 1,62 1,7 1,77 1,86 1,93 2 2,06 2,13 2,18 2,2
12,1 12 11,9 11,8 11,7 11,4 11,1 10,6 9,8 9 7,5 5,7
B-N4 80-200B/A N4 80-200B/A 100 L4 3 1,8 1,88 2 2,1 2,22 2,33 2,43 2,52 2,62 2,68 2,72 2,72
13,9 13,8 13,7 13,6 13,5 13,3 13 12,6 11,8 11 9,6 7,9 6
B-N4 80-200A/A N4 80-200A/A 112 M4 4 2,13 2,22 2,35 2,48 2,65 2,8 2,94 3,05 3,2 3,35 3,44 3,46 3,44
B-N4 80-250C/A N4 80-250C/A 16,9 16,8 16,7 16,6 16,3 15,9 15,4 14,8 13,9 12,7 11,1 9,3 7,2
112 M4 4 2,37 2,5 2,65 2,8 3 3,2 3,35 3,49 3,68 3,83 3,97 3,98 3,88
Hm 20,7 20,6 20,5 20,4 20,3 20 19,6 19,1 18,2 17,1 15,4 13,5 11,4 9*
B-N4 80-250B/A N4 80-250B/A 132 S4 5,5 3,25 3,38 3,58 3,75 4 4,23 4,42 4,6 4,87 5,13 5,35 5,49 5,55 5,45
P3 kW 23,7 23,7 23,6 23,5 23,3 23 22,7 22,2 21,5 20,5 19 17,2 15,1 12,7*
B-N4 80-250A/A N4 80-250A/A 132 M4 7,5 3,94 4,1 4,33 4,54 4,83 5,08 5,33 5,58 5,91 6,23 6,54 6,82 6,98 7,05
B-N4 80-315C/B N4 80-315C/B 160 M4 11 25,7 25,8 25,8 25,8 25,8 25,6 25,4 25 24,4 23,6 22,2 20,4 18,3 15,9
4,6 4,8 5,1 5,4 5,7 6,1 6,4 6,7 7,2 7,6 8,1 8,5 8,9 9,2
B-N4 80-315B/B N4 80-315B/B 160 M4 11 30,3 30,5 30,6 30,7 30,7 30,7 30,5 30,2 29,6 28,8 27,5 25,9 24,1 22
5,3 5,5 5,9 6,2 6,6 7 7,5 7,9 8,5 9 9,7 10,2 10,8 11,2
B-N4 80-315A/B N4 80-315A/B 160 L4 15 36,3 36,4 36,5 36,6 36,6 36,5 36,4 36,1 35,6 35 33,9 32,5 30,9 29 25,3
6,7 6,9 7,3 7,7 8,2 8,7 9,2 9,7 10,4 11,1 12 12,7 13,4 14 14,8
B-N4 80-315S N4 80-315S 180 M4 18,5 39,1 39,2 39,3 39,4 39,5 39,4 39,3 39,2 38,7 38,1 37,1 35,7 34,1 32,1 28,3 22,5*
7,6 7,8 8,3 8,7 9,2 9,8 10,3 10,8 11,6 12,4 13,4 14,3 15,1 15,8 16,8 17,7
18,5 42,8 42,8 42,8 42,8 42,7 42,5 42,2 41,8 41 39,8 37,9 35,4 32,4 29,1
B-N4 80-400C/B N4 80-400C/B 180 M4 8,2 8,5 9 9,4 10,1 10,7 11,3 11,9 12,8 13,7 14,7 15,7 16,6 17,4
B-N4 80-400B/B N4 80-400B/B 180 L4 22 48,2 48,2 48,2 48,2 48,1 47,9 47,7 47,3 46,6 45,7 44,1 42,1 39,5 36,3 30,5
9,7 10,1 10,6 11,1 11,7 12,4 13,1 13,8 14,8 15,7 17 18,2 19,4 20,4 21,8
30 61,4 61,5 61,5 61,6 61,6 61,5 61,3 61,1 60,7 60,1 59 57,6 55,8 53,7 49,5
B-N4 80-400A/B N4 80-400A/B 200 L4 12,8 13,2 13,9 14,5 15,4 16,3 17,2 18,1 19,5 20,8 22,6 24,3 25,9 27,4 29,4
B-N4 80-400S N4 80-400S 225 S4 37 61,4 61,5 61,5 61,6 61,6 61,5 61,3 61,1 60,7 60,1 59 57,6 55,8 53,7 49,5 43,9 39,2*
12,8 13,2 13,9 14,5 15,4 16,3 17,2 18,1 19,5 20,8 22,6 24,3 25,9 27,4 29,4 31,3 32,4
N4 Standard construction. P2 Rated motor power output. H Total head in m. * Maximum suction lift 1-2 m.
B-N4 Bronze construction. P3 Pump power input.
73
N4 End-Suction Centrifugal Pumps
standardized EN 733
PUMP
POMPA PUMP
POMPA Q m3/h 48 54 60 66 75 84 96 108 120 132 150 168 180 192 210
MOTOR
MOTORE P2
B-N4 N4 kW Q l/min 800 900 1000 1100 1250 1400 1600 1800 2000 2200 2500 2800 3000 3200 3500
B-N4 100-400B/A N4 100-400B/A 200 L4 30 50,2 50,1 50 49,9 49,7 49,4 48,8 48 47,1 46 44 41,3 39,5 37 33,5*
15,2 16 16,8 17,4 18,4 19,3 20,6 21,8 23 24,2 25,7 27 27,8 28,5 29,4
B-N4 100-400A/A N4 100-400A/A 225 S4 37 58,2 58,1 58 57,9 57,8 57,6 57,2 56,3 55,7 54,5 52,7 50,5 49 47 44*
17,8 18,75 19,7 20,5 21,7 22,9 24,4 25,9 27,4 28,8 30,9 32,7 33,85 35 36,5
PUMP
POMPA PUMP
POMPA Q m3/h 84 96 108 120 132 150 168 180 192 210 240 270 300 330
MOTOR
MOTORE P2
B-N4 N4 kW Q l/min 1400 1600 1800 2000 2200 2500 2800 3000 3200 3500 4000 4500 5000 5500
5,5 11 10,8 10,5 10,1 9,7 9,1 8,3 7,8 7,2 6,2 4,4
B-N4 125-250E/A N4 125-250E/A 132 S4 4,2 4,5 4,75 4,95 5,05 5,2 5,35 5,45 5,5 5,5 5,35
14 13,9 13,7 13,4 13 12,4 11,6 11 10,4 9,4 7,4 5,1
B-N4 125-250D/A N4 125-250D/A 132 M4 7,5 5,4 5,7 5,95 6,2 6,45 6,75 7 7,1 7,2 7,35 7,4 7,1
16,7 16,6 16,4 16,2 15,9 15,4 14,6 14,1 13,5 12,5 10,4 8,2 5,8
B-N4 125-250C/A N4 125-250C/A 160 M4 11 6,3 6,7 7,1 7,4 7,65 8,05 8,4 8,6 8,75 9 9,2 9,2 9,05
19,3 19,2 19,1 18,9 18,7 18,2 17,5 17 16,3 15,3 13,3 10,9 8,2
B-N4 125-250B/A N4 125-250B/A 160 M4 11 7,8 8,25 8,7 9,1 9,45 10 10,35 10,6 10,85 11,1 11,4 11,45 11,3
22,7 22,7 22,6 22,4 22,2 21,8 21,2 20,8 20,1 19,33 17,4 15 12,4 9,3
B-N4 125-250A/A N4 125-250A/A 160 L4 15
Hm 9,2 9,75 10,3 10,85 11,3 12 12,6 12,95 13,25 13,75 14,3 14,5 14,55 14,4
27,9 27,8 27,7 27,6 27,2 26,5 25,6 24,9 24 22,8 20,2 17 13,5 9,5*
B-N4 125-315C/A N4 125-315C/A 180 M4 18,5 11,5 12,15 12,8 13,4 14 14,7 15,4 15,8 16,2 16,7 17,3 17,7 18 18
P3 kW
31,8 31,7 31,6 31,5 31,1 30,6 29,7 29,1 28,5 27,3 24,9 22 18,5 14,3*
B-N4 125-315B/A N4 125-315B/A 180 L4 22 12,75 13,6 14,45 15,3 15,9 16,8 17,7 18,4 19 19,7 20,6 21,4 22 22,1
36,8 36,8 36,7 36,6 36,4 35,9 35,2 34,7 34,2 33,2 31 28,4 25,3 21,6*
B-N4 125-315A/A N4 125-315A/A 200 L4 30 15,5 16,5 17,5 18,3 19,1 20,4 21,6 22,4 23,1 24,15 25,6 26,6 27,6 28,45
45,4 45,3 45,2 45,1 44,9 44,4 43,7 43 42 40 37 33 28,5* 23,5*
B-N4 125-400C/A N4 125-400C/A 225 S4 37 19,4 20,7 22 23,3 24,6 26,5 28,2 29,3 30,2 31,4 33,4 35 35,9 36,75
B-N4 125-400B/A N4 125-400B/A 225 M4 45 51,4 51,3 51,2 51,1 50,9 50,4 49,7 49 48,2 46,8 44 40,5 36* 31,5*
22,9 24,3 25,7 27,1 28,4 30,35 32,2 33,3 34,4 36 38,5 41 43 44,5
B-N4 125-400A/A N4 125-400A/A 250 M4 55 59,2 59,1 59 58,9 58,7 58,2 57,7 57,2 56,7 55,7 53,5 50,5 46,5* 42,5*
27,8 29,4 30,9 32,4 33,9 36,2 38,4 39,8 41,2 43,2 46,2 49,2 52,1 54,4
PUMP
POMPA PUMP
POMPA Q m3/h 132 150 168 180 192 210 240 270 300 330 360 390 420 450 480
MOTOR
MOTORE P2
B-N4 N4 kW Q l/min 2200 2500 2800 3000 3200 3500 4000 4500 5000 5500 6000 6500 7000 7500 8000
N4 Standard construction. P2 Rated motor power output. H Total head in m. * Maximum suction lift 1-2 m.
B-N4 Bronze construction. P3 Pump power input.
74
N End-Suction Centrifugal Pumps
standardized EN 733
Hm
50
H ft
H ft
15
F Ø 103 25
80
40
10
30 20
60
20
5 15
0 3 5 10 15 20 25 0 3 5 10 15
Q m /h Q m /h
0 l/min 100 200 300 400 0 l/min 100 200 300
0 l/s 1 2 3 4 5 6 0 l/s 1 2 3 4 5
1.6 2.4
S 2.0 A 3
2.0
1.2 1.6
A B 3~
P kW
P kW
P HP
P HP
1.2 B 1~ 2
0.8 D
0.8
F 1.0
0.4
0.4 1
0 0 0.4
8 8 25
NPSH m
NPSH m
6 20 6 20
NPSH ft
NPSH ft
15
4 4
10 10
2 2 5
0 72.010
0 0 72.011
0
0 Q m3/h 5 10 15 20 25 0 Q m3/h 5 10 15
ft ft
Hm
HHmm
25 F Ø 112 80
50
H ft
HH
15
140 20
60
D Ø 178 40
40
15
10 40
120 30
10
5 20
0 m 3/h 10 20 30 20
30 100 50 Q
0 3 5 10 15 0 3 l/min
5 10 200 15 20 400
25 30 35
Q m /h 5 Q m /h
0 l/min 100 200 300 0 l/min 100 200 300 400 500 6
4 A
5
0 l/s 1 2 3 4 5 30 l/s 1 2 3 4 5 6 7 8 9 4
P kW
B
P HP
6 2.5
2 C 3
4 A A 3.0
2
1
2.0 1
5 2.5
0 C 0
P kW
C 1.5
η (%) P kW
2.0
P HP
P HP
3 4 80
F 1.5
1.0
60
D 3
2 1.0
0.5 A
40 C B 0.5
2
1 0
20 0
5 40
15 10
30
NPSH m
NPSHm m
4 C B 10
83 A
NPSH ft
NPSHft ft
10
NPSH
62 20
NPSH
2 5
5 4
1 10
2
0 72.012
0 00 00
72.014
0 Q m3/h 5 10 15 0
0 Q mQ3/hm35/h 10
10 15 20
20 25 3030 35
75
η
η
N End-Suction Centrifugal Pumps
standardized EN 733
H ft
H ft
40
Hm
Hm
30 100
10 30
20 20
50 5
10 10
0 0 0 0
0 3 10 20 30 0 m 3/h 10 20 30 40 50
0
Qm /h
l/min 200 400 0
Q
l/min 200 400 600 800
8 2,5
10 A 3
A 2
6 8 C
B 1,5 2
P kW
P kW
P HP
6
P HP
4 C 1 F
4 1
2 0,5
2
0 0 0
0
80 80
60 A
60
C
η (%)
F
η (%)
40 40
C B A
η
20 20
0 0
6 5
A F A
4
NPSH m
NPSH m
NPSH ft
C
NPSH ft
4 3 10
10 2
B
2
1
0 0 0
0 0 Q m 3/h 10 20 30 40 50
0 Q m3/h 10 20 30
0 U.S. g.p.m. 50 100 150 200 0 U.S. g.p.m. 50 100 150 200
40 130 70
A Ø167 120
200
35 NM 40/16
N 40-160 110 60 A Ø 204
AR Ø 200 NM 40/20
N 40-200
B Ø 151 100 B Ø 195
30
90 50
80 C Ø 185
25 C Ø 137
70 40
D Ø 180
H ft
H ft
20
Hm
Hm
60 100
30
15 50
40
20
10 30
20
5 10
10
0 0 0 0
0 3 10 20 30 40 50 0 3 10 20 30 40 50
0
Q m /h 200 400 600 800 0
Q m /h 200 400 600 800
l/min l/min
5 10
A 6 12
4 5 8 AR A 10
3 B 4 6 B 8
P kW
P kW
P HP
P HP
2 C 3 4 D
6
2 4
1 1 2 C 2
0 0 0 0
80 80
AR
60 A 60
B B A
η (%)
η (%)
40 C 40 C
D
20 20
0 0
6 8 D A
A
NPSH m
NPSH m
C 6 20
NPSH ft
NPSH ft
4
10 4
2 10
2
0 0 0 0
0 Q m3/h 10 20 30 40 50 0 Q m3/h 10 20 30 40 50
76
η
η
N End-Suction Centrifugal Pumps
standardized EN 733
H ft
50
H ft
Hm
50
150
Hm
40
40
10 30
30 100
20 20
50
10 10
0 0 0 0
0 m3/h 10 20 30 40 50 0 m3/h 20 30 40 50 60 70 80 90
Q Q l/min
0 l/min 200 400 600 800 0 500 1000 1500
16 5
A 20 S 6
4
12
B 16 A
D
P kW
3 4
P HP
C 12
P kW
8 F
P HP
8 2
4
2
4 1
0 0 0 0
60
A 80
B
40 C 60 S
η (%)
F D A
η (%)
40
20
20
0 0
6 8
NPSH m
6 20
NPSH m
NPSH ft
4 F S
NPSH ft
10 4
10
2 2
0 0 0 0
0 Q m3/h 10 20 30 40 50 0 Q m3/h 20 30 40 50 60 70 80 90
0 U.S. g.p.m. 100 150 200 250 300 350 0 U.S. g.p.m. 100 150 200 250 300 350
40 130 70
A Ø 174 120
S Ø 209
N 50-160
NM 50/16 110 60
A Ø 200
N 50-200
NM 50/20 200
B Ø 162 100
30 50 B Ø 188
90
150
80
40
H ft
H ft
70
20
Hm
Hm
60 100
30
50
40 20
10 30 50
20 10
10
0 0 0
0 0 20 30 40 50 60 70 80 90
0 m3/h 20 30 40 50 60 70 80 90 m3/h
Q l/min Q l/min
0 500 1000 1500 0 500 1000 1500
8 15 20
A 10
6
S
B 8 A 15
P kW
P kW
10
P HP
P HP
4 6 B
4 10
2 5
2
3 5
0 0
80 80
A 60 S
60 A
B
η (%)
η (%)
40 B
40
20 20
0 0
8
B
NPSH m
NPSH m
6 20 6 20
A
NPSH ft
NPSH ft
4 4
10 10
2 2
0 0 0 0
0 Q m3/h 20 30 40 50 60 70 80 90 0 Q m3/h 20 30 40 50 60 70 80 90
77
N End-Suction Centrifugal Pumps
standardized EN 733
H ft
H ft
H ft
Hm
Hm
50 50
Hm
150
150 40
40 40 10 30
30 30 100
100 20
20 20 10
5050
10 10 0 0
0 0 m3/h
m3/h 2020 3030 4040 5050 6060 7070 8080 0 m3/h 20 30 40 50 60 70 80 90 100 110 120 130
Q Q l/min Q l/min
0 0 l/min 500
500 1000
1000 0 500 1000 1500 2000
8
SS 3030 A 10
20 20
AA 6 8
C
2020
P kW
BB
P kW
6
P kW
P HP
P HP
CC 4 E
P HP
10 10 4
1010 2
2
0 0 00 0 0
80 80
80 A
60 60 A A/S
A/S E
C
B B 60
η (%)
η (%)
40 40
η (%)
CC 40
20 20 20
0 0 0
10 8
10
3030
8
NPSH m
NPSH m
8 20
NPSH m
6
NPSH ft
6 20 A
NPSH ft
6 20 E
NPSH ft
4 4
4 10 10
2 10 2
2
0 0
0 0 0 0
QQ
0 3 20 30 40 50 60 70 80
m /h 0 Q m3/h 20 30 40 50 60 70 80 90 100 110 120 130
0 m 3/h 20 30 40 50 60 70 80
0 U.S. g.p.m. 100 200 300 400 500 600 0 U.S. g.p.m. 150 300 450 600
A Ø 175 60
190
40 N 65-160
NM 65/16 130 A Ø 206
NM 65/20
N 65-200 180
AR Ø 167 120
B Ø 193 170
B Ø 160 110 50 160
100 C Ø 182 150
30 C Ø 150
90 140
H ft
130
H ft
40
Hm
D Ø 143
Hm
80
120
70 110
20
60 100
30
90
50
80
40
70
10 20
0 m /h 20
3 30 40 50 60 70 80 90 100 110 120 130 140 0 3 30 60 90 120 150
Q l/min 0
Qm /h
l/min 500 1000 1500 2000 2500
0 500 1000 1500 2000
16 25
A 20 A 30
AR 20 25
12 16 B
B 20
P kW
15 C
P kW
C
P HP
8 12 15
D
P HP
10
8 10
4 5
4 5
0 0 0 0
100
A
80 AR
D 80 B
C B A
60 C
η (%)
η (%)
60
40
40
20
0 20
8 A
6 20
C
NPSH m
A
NPSH m
6 20
NPSH ft
D 4
NPSH ft
4 10
10 2
2
0 0 0 0
0 Q m3 /h 20 30 40 50 60 70 80 90 100 110 120 130 140 0 Q m3/h 30 60 90 120 150
78
N End-Suction Centrifugal Pumps
standardized EN 733
H ft
C Ø 155 100
30
70 D Ø 147
220
H ft
25 E Ø 140 80
Hm
Hm
C Ø 212
200
60 20 60
180
15
50 160 40
10
140 20
40 5
0 20
3 30 40 50 60 70 80 90 100 110 120 130 140 0 3 50 100 150 200
Q m /h Q m /h
0 l/min 500 1000 1500 2000 20
0 l/min 1000 2000 3000
40 A
A 50 16
30 B B 20
40
12
P kW
P kW
C
P HP
20 C 30 D
8
P HP
20 E 12
10 4
10
0 0 0 0
80 A
C 80 A
60 B D C B
60 E
η (%)
η (%)
40
40
20
20
0
8 8
C
NPSH m
A
NPSH m
6 E A 20
NPSH ft
6 20
4
NPSH ft
4
10 10
2 2
0 0 0 0
0 Q m3 /h 20 30 40 50 60 70 80 90 100 110 120 130 140 0 Q m3/h 50 100 150 200
0 U.S. g.p.m. 200 400 600 800 0 U.S. g.p.m. 200 400 600 800
60 100
A Ø 264
A Ø 210 60 65 68
72 NM(S) 80/250
N 80-250
70
73
N 80-200
NM(S) 80/200 180
90 74
76
300
B Ø 250 η 77%
74
75 80 76
50 C Ø 238 250
160
B Ø 198
70
η 76%
Hm
Hm
D Ø 226
H ft
140 60 200 H ft
40 E Ø 207
50
120 150
40
68
30 100 30 100
0 3 50 100 150 200 3
0 50 100 150 200
Q m /h Q m /h
0 l/min 1000 2000 3000 0 l/min 1000 2000 3000
0 l/s 10 20 30 40 50 0 l/s 10 20 30 40 50
30 40 60 80
A
A
B 30 B 60
20 40
P kW
P kW
C
P HP
P HP
20 D 40
10 20 E
10 20
0 0 0 0
8 25
8 25
NPSH m
NPSH m
6 20
NPSH ft
NPSH ft
6 20
15
4 15
10 4
10
2 5 2 5
0 72.027
0 0 0
72.028
0 Q m3/h 50 100 150 200 0 Q m3/h 50 100 150 200
79
N End-Suction Centrifugal Pumps
standardized EN 733
Hm
140
H ft
H ft
40 70
D Ø 180 74
120
60 200
E Ø 168
30 100
70
65 50
80
150
20
60 40
0 Q m3/h 50 100 150 200 250 300 0 Q m3/h 50 100 150 200 250 300
0 l/min 1000 2000 3000 4000 5000 0 l/min 1000 2000 3000 4000 5000
0 l/s 10 20 30 40 50 60 70 80 0 l/s 10 20 30 40 50 60 70 80
50 80
A A 100
60
40 B 60 B 80
C
P kW
P kW
30 40
P HP
P HP
60
40
20 D
E 40
20 20
10 20
0 0 0 0
10 10
30
NPSH m
NPSH m
8 26 8
NPSH ft
NPSH ft
6 20
6
16 4
4 10
2
2 72.033
6 0 72.034
0
0 Q m3/h 50 100 150 200 250 300 0 Q m3/h 50 100 150 200 250 300
80
N4 End-Suction Centrifugal Pumps
standardized EN 733
H ft
10
Hm
3 55
20
Hm
H ft
6
2
5
4
1
10
0 0
0 3 5 10 12
Qm /h
2
0 l/min 50 100 150 200 0 3
0,3 0,4 Q m /h 2 4 6 8 10 12
0 l/min 50 100 150 200
0,2 A 0,3
l/s
0 1 2 3 3.6
P kW
D
P HP
0,2 0.4
0,1 F 0.5
0,1
0.3
A
0.4
0 0
P kW
P HP
80 0.3
0.2
60 0.2
0.1
η (%)
40 0.1
20 0 0
0 8 25
4
NPSH m
6 20
NPSH ft
NPSH m
3 10
15
NPSH ft
4
2 10
5 2
1 5
0 0
0 0 0 Q m3/h 2 4 6 8 10 72.074
12
0 Q m 3/h 5 10 72.076N 12
0 U.S. g.p.m. 20 30 40 50 60
50
15 A Ø 204 N4 32-200
B Ø 195
40
35 40
45 48
50 52
10
η 53%
Hm
30
H ft
52
5048
45
40
35
20
5
10
0 0
0 3
Q m /h 2 4 6 8 10 12 14
0 l/min 50 100 150 200
0 l/s 1 2 3 3.8
1.0
1.2
0.8
1.0
A
P kW
0.6 0.8
P HP
B
0.4 0.6
0.4
0.2
0.2
0 0
8 25
NPSH m
6 20
NPSH ft
15
4
10
2
5
0 72.075
0
0 Q m3/h 2 4 6 8 10 12 14
81
N4 End-Suction Centrifugal Pumps
standardized EN 733
35
10 A Ø 167 N4 40-160 16
A Ø 204 40
N4 40-200 50
50
30 54 56
B Ø 151 14 η 58%
8 B Ø 195
25 56
54
C Ø 137 12 50 40
H ft
20
Hm
6
Hm
H ft
15 10
4 30
10 40
8
2
5
6 20
0 0
0 m 3/h 10 20 30
0
Q l/min 100 200 300 400 500
4
0 3 5 10 15 20
0,6 0,8 Q m /h
0,5 A 0 l/min50 100 150 200 250 300 350
0,6
0,4 B 0 l/s 1 2 3 4 5 6
P kW
P HP
P HP
80 0.6
60 0.4
η (%)
40 C B A 0.2
20 0 0
0 8 25
8 25
NPSH m
6 20
NPSH ft
NPSH m
6 20
15
NPSH ft
15 4
4 10
10 2
2 5
5
0 0
0 0 0 5 10 15 20 72.077
0 Q m 3/h 10 20 72.076N 30 Q m3/h
15 50 5 F Ø 124
15
H ft
H ft
40 4
Hm
Hm
10 10
30 3
20 2
5 5
10 1
0 0 0 0
0 3 10 20 30 0 3 10 20 30 40
0
Qm
/h
l/min 100 200 300 400 500 0
Qm /h
l/min 200 400 600
3 4 0,8
1
A 0,6 S
3 0,8
2 A
P kW
P kW
0,6
P HP
P HP
B 2 0,4 D
C F 0,4
1
1 0,2
0,2
0 0 0 0
60 80
60
40 A
η (%)
η (%)
40
20 B
C 20
0 0
9 4
25
NPSH m
NPSH m
3 10
6 20
NPSH ft
NPSH ft
15 2
3 10 5
1
5
0 0 0 0
0 Q m 3/h 10 20 72.076N 30 0 Q m3/h 10 20 30 72.076N
40
82
N4 End-Suction Centrifugal Pumps
standardized EN 733
30 12 C Ø 188 40
B Ø 162
8 35
25 10
30
H ft
H ft
6 20 8 25
Hm
Hm
15 6 20
4
15
10 4
10
2
5 2 5
0 0 0 0
0 m3/h 10 20 30 40 50 0 3 10 20 30 40 50
0
Q l/min 200 400 600 800 0
Qm /h
l/min 200 400 600 800
1,5 2 2
2,5
1,2 A
1,5 1,5 2
0,9 A B
P kW
P kW
1,5
P HP
P HP
1 1 C
0,6 B 1
0,3 0,5 0,5
0,5
0 0 0 0
80 80
60 A 60
A
B
η (%)
η (%)
40 40
B
20 20 C
0 0
9 8 25
25
NPSH m
NPSH m
6 20
6 20
NPSH ft
NPSH ft
15
15 4
3 10 10
2 5
5
0 0 0 0
72.076N 72.076N
0 Q m3/h 10 20 30 40 50 0 Q m3/h 10 20 30 40 50
0 U.S. g.p.m. 50 100 150 200 0 U.S. g.p.m. 100 150 200 250 300
25 80 7
A Ø 255 A Ø 146
N4 65-125
20
B Ø 245
N4 50-250 70 6
20
C Ø 229 60 C Ø 134
5
15 D Ø 209 50 15
E Ø 123
H ft
H ft
40 4
Hm
Hm
10
30 10
3
20
5
2
10
5
0 0 1
0 3 10 20 30 40 50 0 3 10 20 30 40 50 60 70
Qm
/h
Qm
/h
0 l/min 200 400 600 800 0 l/min 500 1000
4 1,5 2
5
3 A 4 1,5
1 A
B
P kW
P kW
P HP
3
P HP
2 1
C C
D 2 0,5 E
1 0,5
1
0 0 0 0
70
60 80 A
C
A 60 E
40
η (%)
η (%)
C B 40
20
D 20
0 0
9 4
25
NPSH m
NPSH m
3 10
20
NPSH ft
NPSH ft
6 E A
15 2
10 5
3
1
5
0 0 0 0
0 Q m3/h 10 20 30 40 72.076N
50 0 Q m 3/h 10 20 30 40 50 60 72.082N 70
83
N4 End-Suction Centrifugal Pumps
standardized EN 733
H ft
H ft
6 20 8
Hm
Hm
15 6 20
4
10 4
10
2
5 2
0 0 0 0
0 3 30 60 90 0 3 20 40 60 80 100
Qm /h m /h
0 l/min 300 600 900 1200 1500 0
Q l/min 500 1000 1500
3 4
3 A 4
3
2 S B 3
P HP
2
P kW
P kW
P HP
A 2
2
1 B 1
C 1 1
0 0 0 0
80 80
A
60 C B A 60
S
η (%)
η (%)
40 40 B
20 20
0 0
8 25 8 25
NPSH m
NPSH m
6 20 6 20
NPSH ft
NPSH ft
15 15
4 4
10 10
2 2
5 5
0 0 0 0
0 Q m /h
3 30 60 72.082N 90 0 Q m /h
3 20 40 60 80 72.082N 100
0 U.S. g.p.m. 100 150 200 250 300 350 400 0 U.S. g.p.m. 100 200 300 380
24 40
A Ø 252
NM4 65/25
N4 65-250 A Ø 321.5 50
60
64 NM4
N4 65/31
65-315 120
20
B Ø 230 68
60
B Ø 302 η 69%
16 30 68 100
C Ø 278
H ft
40 64
Hm
12
Hm
H ft
80
8 60
20 20
60
4
50
0 0 40
0 3
m /h 20 40 60 80 100
0
Q l/min 500 1000 1500
10
0 3 20 30 40 50 60 70 80 90
Q m /h
6 8
0 l/min 500 1000 1500
A
0 l/s 5 10 15 20 25
B 6
P HP
4
P kW
4 10
2 A 12
2 8
B 10
0 0
6
P kW
8
P HP
C
80 6
A 4
60 4
η (%)
2
40 2
B
0 0
20
0 4
12
8 25
NPSH m
3 10
NPSH ft
NPSH m
6 20 8
NPSH ft
15 2 6
4
10 1 4
2 2
5
0 0
0 0 0 20 30 40 50 60 70 80 72.087
90
0 Q m3 /h 20 40 60 80 72.082N 100 Q m3/h
84
N4 End-Suction Centrifugal Pumps
standardized EN 733
H ft
20 10
Hm
6
Hm
H ft
70 30
15 9
4 8 65
10
7 60
2
5 6 20
0 0 5
0 3 20 40 60 80 100 120
Qm /h
0 l/min 400 800 1200 1600 2000 4
0 3
3 4 Q m /h 20 40 60 80 100 120
0 l/min 500 1000 1500 2000
A 3
2 0 l/s 10 20 30
P kW
P HP
B 2
4
1 C A 5
1
3 B 4
0 0
P kW
P HP
C 3
80 2
C B A 2
60 1
η (%)
1
40
0 0
20
0 8 25
8 25
NPSH m
6 20
NPSH ft
NPSH m
6 20
15
NPSH ft
15 4
4 10
10 2
2 5
5
0 0
0 0 0 72.086
0 Q m 3/h 20 40 60 80 100 72.085N 120 Q m /h 20
3 40 60 80 100 120
50
H ft
15
40
10
30
20
5
0 3 50 100 150
Q m /h
0 l/min 500 1000 1500 2000 2500
0 l/s 10 20 30 40
8
A 10
6 8
B
P kW
P HP
6
4 C
4
2
2
0 0
8 25
NPSH m
6 20
NPSH ft
15
4
10
2
5
0 72.088
0
0 Q m3/h 50 100 150
85
N4 End-Suction Centrifugal Pumps
standardized EN 733
50 B Ø 363 S Ø 403
B Ø 295
30 100 150
C Ø 345
Hm
H ft
Hm
C Ø 277 40
H ft
80
30 100
20
60
20
50
40
10 10
0 3 50 100 150 180 0 3 50 100 150 180
0
Q m /h 500 1000 1500 2000 2500 3000 0
Q m /h 500 1000 1500 2000 2500 3000
20 l/min 40 l/min
S S
16 A
A 20 30 40
P kW
P kW
12
P HP
P HP
B B
20
8 C 10 C 20
4 10
0 0 0 0
80 80
A A
70 70
B S
(%)
(%)
60 C S 60 C B
50 50
40 40
10 10
S 30 S 30
8 8
NPSH m
NPSH m
NPSH ft
NPSH ft
6 20 6 20
4 C 4 C
10 10
2 2
0 0 0 0
0 Q m3/h 50 100 150 180 0 Q m3/h 50 100 150 180
86
N4 End-Suction Centrifugal Pumps
standardized EN 733
Hm
73 70
H ft
H ft
70 30 40
65
60
10
30
20
5
20
5
10
10
0 0 0 0
3 3
0 50 100 150 200 0 50 100 150 200
Q m /h Q m /h
0 l/min 500 1000 1500 2000 2500 3000 0 l/min 1000 2000 3000
0 l/s 10 20 30 40 50 0 l/s 10 20 30 40 50 60
6 8 10
A A 12
5 8
6 B 10
4
P kW
P kW
B 6 8
P HP
P HP
3 C 4
4 6
2 4
2 2
1 2
0 0 0 0
8 25 8 25
NPSH m
NPSH m
6 20 6 20
NPSH ft
NPSH ft
15 15
4 4
10 10
2 2
5 5
0 72.091
0 0 72.092
0
0 Q m /h
3 50 100 150 200 0 Q m /h
3 50 100 150 200
0 U.S. g.p.m. 200 400 600 800 0 U.S. g.p.m. 200 400 600 800
40 60
A Ø 328 65 A Ø 405
70 73
NM(S)4 100/315 120 N4 100-400
NMS4 100/400 180
75
N4 100-315
B Ø 377 55 60
B Ø 306 50 64
67 160
30 75 100
68
η 77%
C Ø 286 73
C Ø 347 67 140
Hm
Hm
70
H ft
H ft
80 40
64 120
η 69%
20 65
60 100
30
60
80
40
10 20
3
0 50 100 150 200 0 m3/h 50 100 150 200
Q m /h Q
0 l/min 1000 2000 3000 0 l/min 1000 2000 3000
0 l/s 10 20 30 40 50 60 0 l/s 10 20 30 40 50 60
20 40
A 25 A 50
20 30 B 40
B
P kW
P kW
P HP
P HP
C 15 C 30
10 20
10 20
10
5 10
0 0 0 0
10 8 25
30
NPSH m
NPSH m
6 20
NPSH ft
NPSH ft
20 15
5 4
10
10 2
5
0 72.093
0 0 0
72.094
0 Q m3/h 50 100 150 200 0 Q m3/h 50 100 150 200
87
N4 End-Suction Centrifugal Pumps
standardized EN 733
Hm
H ft
H ft
40 20
E Ø 203 60 60 60
10
40
20 10
5
20
0 0 0 0
3 3
0 100 200 300 0 100 200 300
Q m /h Q m /h
0 l/min 1000 2000 3000 4000 5000 0 l/min 1000 2000 3000 4000 5000
0 l/s 20 40 60 80 0 l/s 20 40 60 80
18 30 40
A
A 20 B
30
B 20 C
P kW
P kW
P HP
P HP
10
C 20
D 10
E 10
10
0 0 0 0
8 8
NPSH m
NPSH m
6 20 6 20
NPSH ft
NPSH ft
4 4
10 10
2 2
0 72.095
0 0 72.096
0
0 Q m3/h 100 200 300 0 Q m3/h 100 200 300
60 65 200
60 A Ø 405 70
73 NMS4 125/400
N4 125-400
75
η 76% 180
B Ø 380 75
50 73 160
C Ø 364 70
Hm
140
H ft
40
66 120
30 100
60
80
20
3
0
Q m /h 50 100 150 200 250 300 350
0 l/min 1000 2000 3000 4000 5000 5800
0 l/s 10 20 30 40 50 60 70 80 90
60 80
A
50
B 60
40
P kW
C
P HP
30 40
20
20
10
0 0
8
NPSH m
6 20
NPSH ft
4
10
2
0 72.097
0
0 Q m3/h 50 100 150 200 250 300 350
88
N4 End-Suction Centrifugal Pumps
standardized EN 733
Hm
65
H ft
H ft
20
60 70
30 100
60
40 65
10 60
20
20
50
0 0 10
3 3
0 100 200 300 400 500 0 100 200 300 400 500
Q m /h Q m /h
0 l/min 2000 3000 4000 5000 6000 7000 8000 0 l/min 2000 3000 4000 5000 6000 7000 8000
P kW
P HP
P HP
C 30 C
20 40 50
D
20
10 20
10
0 0 0 0
8 25 10
30
NPSH m
NPSH m
6 20
NPSH ft
NPSH ft
15 20
4 5
10
2 10
5
0 72.098
0 0 72.099
0
0 Q m3/h 100 200 300 400 500 0 Q m3/h 100 200 300 400 500
89
N, N4 End-Suction Centrifugal Pumps
standardized EN 733
Interchangeability of parts
N4 80-315 X X X X
N4 80-400 X X X X
N,N4 100-200 X X X X
N,N4 100-250 X X X X
N4 100-315 X X X X
N4 100-400 X X X X
N4 125-250 X X X X
N4 125-315 X X X X
N4 125-400 X X X X
N4 150-315 X X X X
N4 150-400 X X X X
Suction pipe: recommended minimum inside diameter (DN) for different capacities (Q)
Q max m /h
3 10,5 19 28,8 45 75 108 215 350 508
90
N, N4 End-Suction Centrifugal Pumps
standardized EN 733
a f x
DN2 l1 l2
h2
DN1
h1
m2 s1 14 b
m1 110
w n2
n1
Shaft extension ISO 775 Parallel key UNI 6604 Flanges PN 10, EN 1092-2
mm
u mm
DG DN DG DK DE Holes W
d l u t
t
24 j6 50 8 27 N° Ø
32 k6 80 10 35 32 76 100 140 4 19 18
d 4.93.114
42 k6 110 12 45 W DN 40 84 110 150 4 19 18
DK 50 99 125 165 4 19 20
DE 65 118 145 185 4 19 20
4.93.094
80 132 160 200 8 19 22
100 156 180 220 8 19 24
N n = 2900 1/min
125
150
200
184
211
266
210
240
295
250
285
340
8
8
8
19
23
23
24
26
30
N4 n = 1450 1/min
mm kg
TYPE
TIPO
a x B-N N
DN1 DN2 f h1 h2 l1 l2 m1 m2 n1 n2 b s1 d w B-N4 N4
B-N, B-N4 - N, N4 32-125 112 140 93 97 190 140 30 26,5
B-N, B-N4 - N, N4 32-160 132 160 120 120 37 33
B-N, B-N4 - N, N4 32-200 50 32 80 360 160 180 140 140 100 70 240 190 50 14 24 260 100 44 38,4
B-N, - N, 32L-160 132 160 120 120 35,8 33,2
B-N, - N, 32L-200 160 180 140 140 265 212 43,8 40
B-N, - N, 40-125 112 140 100 113 210 160 32 28,4
80
B-N, B-N4 - N, N4 40-160 132 160 119 119 100 70 240 190 50 38 33,6
65 40 360 14 24 260 100
B-N, B-N4 - N, N4 40-200 160 180 140 140 265 212 47,1 40,4
100
B-N, B-N4 - N, N4 40-250 180 225 175 175 125 95 320 250 65 63 55
B-N, B-N4 - N, N4 50-125 132 160 121 137 240 190 42,4 36,5
B-N, B-N4 - N, N4 50-160 180 127 141 100 70 50 45 39,2
160 265 212
B-N, B-N4 - N, N4 50-200 65 50 100 360 200 140 153 14 24 260 100 54 47
B-N, B-N4 - N, N4 50-250 180 225 175 175 125 95 320 250 65 66 57,5
B-N, B-N4 - N, N4 65-125 180 134 155 48 38,7
160 280 212 100
B-N, B-N4 - N, N4 65-160 360 200 150 172 125 95 65 14 24 260 50,6 44,5
100
B-N, B-N4 - N, N4 65-200 80 65 180 225 155 175 320 250 55,5 50
B-N, B-N4 - N, N4 65-250 200 250 175 190 360 280 140 103 90
470 160 120 80 18 32 340 149 130
B-N4 - N4 65-315 125 225 280 220 220 400 315
B-N, B-N4 - N, N4 80-160 360 225 165 193 320 250 24 260 61 53
180 125 95 65 14
B-N, B-N4 - N, N4 80-200 250 170 194 345 280 140 93 80,5
100 80 125
B-N, B-N4 - N, N4 80-250 470 200 280 191 210 32 340 110 95
160 120 400 315 80 18
B-N4 - N4 80-315 250 315 220 232 154 134
B-N4 - N4 80-400 (1 125 80 125 530 280 355 268 268 160 120 435 355 80 18 42 370 140 220 192
B-N, B-N4 - N, N4 100-200 125 200 180 212 360 280 103 89
280
B-N, B-N4 - N, N4 100-250 470 225 205 233 160 120 80 18 32 340 123 104
125 100 400 315 140
B-N4 - N4 100-315 140 250 315 230 250 158 138
B-N4 - N4 100-400 530 280 355 268 280 200 150 500 400 100 22 42 370 230 200
B-N4 - N4 125-250 470 250 235 268 160 120 400 315 80 18 32 340 150 129
355 217 189
B-N4 - N4 125-315 150 125 140 280 247 278 140
530 200 150 500 400 100 22 42 370
B-N4 - N4 125-400 315 400 280 305 255 222
B-N4 - N4 150-315 280 400 260 298 231 201
200 150 160 530 200 150 550 450 100 22 42 370 140
B-N4 - N4 150-400 315 450 295 328 284 247
1) Additional size
91
N End-Suction Centrifugal Pumps
standardized EN 733
Dimensions
FM
a f
n≈ 2900 rpm
DN 2
DN 1
h2
H
h3
g2
g2
a1 s1
4.93.070
w1 m5 w1 n5 n5
m4 n4 n4
n4 < 400 n4 > 480
mm
TYPE
POMPA MOTOR
MOTORE kW
DN1 DN2 a f h3 h2 m4 m5 w1 n4 n5 a1 g2 s1 FM≈ H≈
B-N, N 32-125 71 M2 0,55 50 32 80 360 197 140 780 750 15 240 180 90 85 14 718 308
80 M2 0,75 50 32 80 360 197 140 780 750 15 240 180 90 85 14 770 319
80 M2 1,1 50 32 80 360 197 140 780 750 15 240 180 90 85 14 770 319
90 S2 1,5 50 32 80 360 197 140 780 750 15 240 180 90 85 14 825 323
B-N, N 32-160 90 S2 1,5 50 32 80 360 217 160 780 750 15 240 180 90 85 14 825 343
90 L2 2,2 50 32 80 360 217 160 780 750 15 240 180 90 85 14 865 343
100 L2 3 50 32 80 360 232 160 880 850 15 300 240 90 100 14 920 398
B-N, N 32-200 90 L2 2,2 50 32 80 360 245 180 780 750 15 240 180 90 85 14 865 371
100 L2 3 50 32 80 360 260 180 880 850 15 300 240 90 100 14 920 426
112 M2 4 50 32 80 360 260 180 880 850 15 300 240 90 100 14 903 437
132 S2 5,5 50 32 80 360 260 180 1020 990 15 350 290 100 100 14 954 462
B-N, N 32L-160 90 L2 2,2 50 32 80 360 217 160 780 750 15 240 180 90 85 14 865 343
100 L2 3 50 32 80 360 232 160 880 850 15 300 240 90 100 14 920 398
112 M2 4 50 32 80 360 232 160 880 850 15 300 240 90 100 14 903 409
B-N, N 32L-200 112 M2 4 50 32 80 360 260 180 880 850 15 300 240 100 100 14 903 437
132 S2 5,5 50 32 80 360 260 180 1020 990 15 350 290 100 100 14 953 462
132 S2 7,5 50 32 80 360 260 180 1020 990 15 350 290 100 100 14 953 462
B-N, N 40-125 80 M2 1,1 65 40 80 360 197 140 780 750 15 240 180 90 85 14 770 319
90 S2 1,5 65 40 80 360 197 140 780 750 15 240 180 90 85 14 825 323
90 L2 2,2 65 40 80 360 197 140 780 750 15 240 180 90 85 14 865 323
B-N, N 40-160 90 L2 2,2 65 40 80 360 217 160 780 750 15 240 180 90 85 14 865 343
100 L2 3 65 40 80 360 232 160 880 850 15 300 240 90 100 14 920 398
112 M2 4 65 40 80 360 232 160 880 850 15 300 240 90 100 14 903 409
132 S2 5,5 65 40 80 360 232 160 1020 990 15 350 290 90 100 14 953 434
B-N, N 40-200 112 M2 4 65 40 100 360 260 180 880 850 15 300 240 100 100 14 923 437
132 S2 5,5 65 40 100 360 260 180 1020 990 15 350 290 100 100 14 973 462
132 S2 7,5 65 40 100 360 260 180 1020 990 15 350 290 100 100 14 973 462
B-N, N 40-250 160 M2 11 65 40 100 360 280 225 1020 990 15 350 290 100 100 14 1082 517
160 M2 15 65 40 100 360 280 225 1020 990 15 350 290 100 100 14 1082 517
B-N, N 50-125 90 L2 2,2 65 50 100 360 217 160 780 750 15 240 180 90 85 14 885 343
100 L2 3 65 50 100 360 232 160 880 850 15 300 240 90 100 14 940 398
112 M2 4 65 50 100 360 232 160 880 850 15 300 240 90 100 14 923 409
132 S2 5,5 65 50 100 360 232 160 1020 990 15 350 290 90 100 14 973 434
B-N, N 50-160 132 S2 5,5 65 50 100 360 260 180 1020 990 15 350 290 100 100 14 973 462
132 S2 7,5 65 50 100 360 260 180 1020 990 15 350 290 100 100 14 973 462
B-N, N 50-200 160 M2 11 65 50 100 360 260 200 1020 990 15 350 290 100 100 14 1082 497
160 M2 15 65 50 100 360 260 200 1020 990 15 350 290 100 100 14 1082 497
B-N, N 50-250 160 M2 11 65 50 100 360 280 225 1020 990 15 350 290 100 100 14 1082 517
160 M2 15 65 50 100 360 280 225 1020 990 15 350 290 100 100 14 1082 517
160 L2 18,5 65 50 100 360 280 225 1020 990 15 350 290 100 100 14 1142 517
180 M2 22 65 50 100 360 280 225 1140 1110 15 350 290 100 100 14 1218 566
B-N, N 65-125 112 M2 4 80 65 100 360 260 180 880 850 15 300 240 100 100 14 923 437
132 S2 5,5 80 65 100 360 260 180 1020 990 15 350 290 100 100 14 973 462
132 S2 7,5 80 65 100 360 260 180 1020 990 15 350 290 100 100 14 973 462
B-N, N 65-160 132 S2 5,5 80 65 100 360 260 200 1020 990 15 350 290 100 100 14 973 462
132 S2 7,5 80 65 100 360 260 200 1020 990 15 350 290 100 100 14 973 462
160 M2 11 80 65 100 360 260 200 1020 990 15 350 290 100 100 14 1112 497
160 M2 15 80 65 100 360 260 200 1020 990 15 350 290 100 100 14 1082 497
B-N, N 65-200 160 M2 15 80 65 100 360 280 225 1020 990 15 350 290 100 100 14 1082 517
160 L2 18,5 80 65 100 360 280 225 1020 990 15 350 290 100 100 14 1142 517
180 M2 22 80 65 100 360 280 225 1140 1110 15 350 290 100 100 14 1218 566
B-N, N 65-250 180 M2 22 80 65 100 470 310 250 1360 1320 20 400 340 130 110 18 1328 596
200 L2 30 80 65 100 470 310 250 1360 1320 20 400 340 130 110 18 1348 625
200 L2 37 80 65 100 470 310 250 1360 1320 20 400 340 130 110 18 1348 625
B-N, N 80-160 132 S2 7,5 100 80 125 360 280 225 1020 990 15 350 290 100 100 14 998 482
160 M2 11 100 80 125 360 280 225 1020 990 15 350 290 100 100 14 1107 517
160 M2 15 100 80 125 360 280 225 1020 990 15 350 290 100 100 14 1107 517
160 L2 18,5 100 80 125 360 280 225 1020 990 15 350 290 100 100 14 1167 517
B-N, N 80-200 180 M2 22 100 80 125 470 290 250 1230 1190 20 400 340 100 110 18 1353 576
200 L2 30 100 80 125 470 310 250 1360 1320 20 400 340 130 110 18 1373 625
B-N, N 80-250 180 M2 22 100 80 125 470 310 280 1360 1320 20 400 340 130 110 18 1353 596
200 L2 30 100 80 125 470 310 280 1360 1320 20 400 340 130 110 18 1373 625
200 L2 37 100 80 125 470 310 280 1360 1320 20 400 340 130 110 18 1373 625
B-N, N 80-250 225 M2 45 100 80 125 470 385 280 1250 840 205 480 430 95 16 24 1470 723
250 M2 55 100 80 125 470 415 280 1250 840 205 480 430 95 16 24 1509 825
B-N, N 100-200 160 L2 18,5 125 100 125 470 310 280 1230 1190 20 400 340 130 110 18 1263 547
180 M2 22 125 100 125 470 310 280 1360 1320 20 400 340 130 110 18 1353 596
200 L2 30 125 100 125 470 310 280 1360 1320 20 400 340 130 110 18 1373 625
200 L2 37 125 100 125 470 310 280 1360 1320 20 400 340 130 110 18 1373 625
B-N, N 100-200 225 M2 45 125 100 125 470 385 280 1250 840 205 480 430 95 16 24 1470 723
B-N, N 100-250 250 M2 55 125 100 140 470 415 280 1250 840 205 480 430 95 16 24 1524 825
280 S2 75 125 100 140 470 505 280 1400 940 230 510 450 95 17,5 24 1597 938
92
N4 End-Suction Centrifugal Pumps
standardized EN 733
Dimensions
n≈ 1450 rpm
mm
TYPE
POMPA MOTOR
MOTORE kW
DN1 DN2 a f h3 h2 m4 m5 w1 n4 n5 a1 g2 s1 fM≈ H≈
B-N4, N4 32-125 71 M4 0,25 50 32 80 360 197 140 780 750 15 240 180 90 85 14 718 308
B-N4, N4 32-160 71 M4 0,37 50 32 80 360 217 160 780 750 15 240 180 90 85 14 718 328
B-N4, N4 32-200 80 M4 0,55 50 32 80 360 245 180 780 750 15 240 180 90 85 14 770 367
80 M4 0,75 50 32 80 360 245 180 780 750 15 240 180 90 85 14 770 367
B-N4, N4 40-125 71 M4 0,25 65 40 80 360 197 140 780 750 15 240 180 90 85 14 718 308
71 M4 0,37 65 40 80 360 197 140 780 750 15 240 180 90 85 14 718 308
B-N4, N4 40-160 71 M4 0,37 65 40 80 360 217 160 780 750 15 240 180 90 85 14 718 328
80 M4 0,55 65 40 80 360 217 160 780 750 15 240 180 90 85 14 770 339
80 M4 0,75 65 40 80 360 217 160 780 750 15 240 180 90 85 14 770 339
B-N4, N4 40-200 90 S4 1,1 65 40 100 360 260 180 880 850 15 300 240 100 100 14 845 386
B-N4, N4 40-250 90 L4 1,5 65 40 100 360 280 225 880 850 15 350 290 100 100 14 885 406
100 L4 2,2 65 40 100 360 280 225 880 850 15 350 290 100 100 14 929 446
100 L4 3 65 40 100 360 280 225 880 850 15 350 290 100 100 14 929 446
B-N4, N4 50-125 71 M4 0,37 65 50 100 360 217 160 780 750 15 240 180 90 85 14 738 328
80 M4 0,55 65 50 100 360 217 160 780 750 15 240 180 90 85 14 790 339
80 M4 0,75 65 50 100 360 217 160 780 750 15 240 180 90 85 14 790 339
B-N4, N4 50-160 90 S4 1,1 65 50 100 360 260 180 880 850 15 300 240 100 100 14 845 386
B-N4, N4 50-200 90 S4 1,1 65 50 100 360 260 200 880 850 15 300 240 100 100 14 845 386
90 L4 1,5 65 50 100 360 260 200 880 850 15 300 240 100 100 14 885 386
100 L4 2,2 65 50 100 360 260 200 880 850 15 300 240 100 100 14 929 426
B-N4, N4 50-250 100 L4 2,2 65 50 100 360 280 225 880 850 15 350 290 100 100 14 929 446
100 L4 3 65 50 100 360 280 225 880 850 15 350 290 100 100 14 929 446
112 M4 4 65 50 100 360 280 225 880 850 15 350 290 100 100 14 912 457
B-N4, N4 65-125 80 M4 0,75 80 65 100 360 260 180 880 850 15 300 240 100 100 14 790 382
90 S4 1,1 80 65 100 360 260 180 880 850 15 300 240 100 100 14 845 386
B-N4, N4 65-160 90 S4 1,1 80 65 100 360 260 200 880 850 15 300 240 100 100 14 845 386
90 L4 1,5 80 65 100 360 260 200 880 850 15 300 240 100 100 14 885 386
100 L4 2,2 80 65 100 360 260 200 880 850 15 350 290 100 100 14 929 426
B-N4, N4 65-200 100 L4 2,2 80 65 100 360 280 225 880 850 15 350 290 100 100 14 929 446
100 L4 3 80 65 100 360 280 225 880 850 15 350 290 100 100 14 929 446
B-N4, N4 65-250 112 M4 4 80 65 100 470 310 250 1030 990 20 400 340 130 110 18 1022 487
132 S4 5,5 80 65 100 470 310 250 1030 990 20 400 340 130 110 18 1123 512
B-N4, N4 65-315 132 S4 5,5 80 65 125 470 335 280 1030 990 20 400 340 130 110 18 1148 537
132 M4 7,5 80 65 125 470 335 280 1030 990 20 400 340 130 110 18 1148 537
160 M4 11 80 65 125 470 335 280 1230 1190 20 400 340 130 110 18 1237 572
B-N4, N4 80-160 90 S4 1,1 100 80 125 360 280 225 880 850 15 350 290 100 100 14 870 406
90 L4 1,5 100 80 125 360 280 225 880 850 15 350 290 100 100 14 910 406
100 L4 2,2 100 80 125 360 280 225 880 850 15 350 290 100 100 14 954 446
B-N4, N4 80-200 100 L4 2,2 100 80 125 470 280 250 1020 990 15 350 290 100 100 14 1064 446
100 L4 3 100 80 125 470 280 250 1020 990 15 350 290 100 100 14 1064 446
112 M4 4 100 80 125 470 280 250 1020 990 15 350 290 100 100 14 1047 457
B-N4, N4 80-250 112 M4 4 100 80 125 470 310 280 1030 990 20 400 340 130 110 18 1047 487
132 S4 5,5 100 80 125 470 310 280 1030 990 20 400 340 130 110 18 1148 512
132 M4 7,5 100 80 125 470 310 280 1030 990 20 400 340 130 110 18 1148 512
B-N4, N4 80-315 160 M4 11 100 80 125 470 360 315 1230 1190 20 400 340 130 110 18 1237 597
160 L4 15 100 80 125 470 360 315 1230 1190 20 400 340 130 110 18 1297 597
180 M4 18,5 100 80 125 470 360 315 1360 1320 20 400 340 130 110 18 1301 646
B-N4, N4 80-400 180 M4 18,5 125 80 125 530 445 355 1250 840 205 480 430 115 16 24 1361 731
180 L4 22 125 80 125 530 445 355 1250 840 205 480 430 115 16 24 1391 760
200 L4 30 125 80 125 530 445 355 1250 840 205 480 430 115 16 24 1439 760
225 S4 37 125 80 125 530 445 355 1250 840 205 480 430 115 16 24 1481 783
B-N4, N4 100-200 100 L4 3 125 100 125 470 310 280 1030 990 20 400 340 130 110 18 1064 476
112 M4 4 125 100 125 470 310 280 1030 990 20 400 340 130 110 18 1047 487
132 S4 5,5 125 100 125 470 310 280 1030 990 20 400 340 130 110 18 1148 512
B-N4, N4 100-250 132 M4 7,5 125 100 140 470 335 280 1030 990 20 400 340 130 110 18 1163 537
160 M4 11 125 100 140 470 335 280 1230 1190 20 400 340 130 110 18 1252 572
B-N4, N4 100-315 160 M4 11 125 100 140 470 360 315 1230 1190 20 400 340 130 110 18 1252 597
160 L4 15 125 100 140 470 360 315 1230 1190 20 400 340 130 110 18 1312 597
180 M4 18,5 125 100 140 470 360 315 1360 1320 20 400 340 130 110 18 1316 646
B-N4, N4 100-400 180 L4 22 125 100 140 530 445 355 1250 840 205 480 430 115 16 24 1406 760
200 L4 30 125 100 140 530 445 355 1250 840 205 480 430 115 16 24 1454 760
225 S4 37 125 100 140 530 445 355 1250 840 205 480 430 115 16 24 1496 783
B-N4, N4 125-250 132 S4 5,5 150 125 140 470 360 355 1030 990 20 400 340 130 110 18 1163 562
132 M4 7,5 150 125 140 470 360 355 1030 990 20 400 340 130 110 18 1163 562
160 M4 11 150 125 140 470 360 355 1230 1190 20 400 340 130 110 18 1252 597
160 L4 15 150 125 140 470 360 355 1230 1190 20 400 340 130 110 18 1312 597
B-N4, N4 125-315 180 M4 18,5 150 125 140 530 445 355 1250 840 205 480 430 115 16 24 1376 731
180 L4 22 150 125 140 530 445 355 1250 840 205 480 430 115 16 24 1406 760
200 L4 30 150 125 140 530 445 355 1250 840 205 480 430 115 16 24 1454 760
B-N4, N4 125-400 225 S4 37 150 125 140 530 480 400 1250 840 205 480 430 115 16 24 1496 818
225 M4 45 150 125 140 530 480 400 1250 840 205 480 430 115 16 24 1556 818
250 M4 55 150 125 140 530 540 400 1400 940 230 510 450 115 17,5 24 1595 950
B-N4, N4 150-315 180 M4 18,5 200 150 160 530 445 400 1250 840 205 480 430 115 16 24 1396 731
180 L4 22 200 150 160 530 445 400 1250 840 205 480 430 115 16 24 1426 760
200 L4 30 200 150 160 530 445 400 1250 840 205 480 430 115 16 24 1474 760
225 S4 37 200 150 160 530 445 400 1250 840 205 480 430 115 16 24 1516 783
B-N4, N4 150-400 225 M4 45 200 150 160 530 480 450 1250 840 205 480 430 115 16 24 1576 818
250 M4 55 200 150 160 530 540 450 1400 940 230 510 450 115 17,5 24 1615 950
280 S4 75 200 150 160 530 540 450 1400 940 230 510 450 115 17,5 24 1688 973
93
N, N4 End-Suction Centrifugal Pumps
standardized EN 733
Features
Flexible
The option to choose between cast iron and bronze materias for the hydraulic parts in contact
with the pumped liquid allows N-N4 series pumps to be selected for use with different types of
liquids.
Robust
The mechanical structure of the hydraulic parts in contact with the pumped liquid are
dimensioned to guarantee the maximum resistence to mechanical stress. Also the casing cover is
provided with wings that prevent turbulence in the area of the mechanical sea, increasing the
reliability.
Reliable
The bearing and shaft are designed to ensure the reduction of the stress, providing high reliability
under all operating conditions.
94
03/2021
Construction
Close-coupled, single-impeller, centrifugal pumps; electric
motor with extended shaft directly connected to the pump.
Applications
For clean liquids, without abrasives, which are non-aggressive
for the pump materials (contents of solids up to 0.2%).
For heating, conditioning, cooling and circulation plants.
For civil and industrial applications.
When low noise operation is required (n ≈ 1450 rpm).
Operating conditions
Liquid temperature from -10 °C to +90 °C.
Ambient temperature up to 40 °C.
Total suction lift up to 7 m.
Maximum permissible working pressure up to 10 bar.
Continuous duty.
Motor
2-pole induction motor, 50 Hz (n ≈ 2900 rpm).
NR(D) : three-phase 230/400 V ± 10% up to 3 kW;
400/690 V ± 10% from 4 to 18,5 kW.
NRM : single-phase 230 V ± 10%.
Insulation class F.
Protection IP 54.
Motor suitable for operation with frequency converter from
0,75 kW for NR4 and from 1,1 kW for NR(D).
The electropumps NR, NR4 series comply with the European Regulation no. Classification scheme IE3 for three-phase motors from 0,75 kW.
547/2012. Constructed in accordance with EN 60034-1, EN 60034-30-1.
Materials EN 60335-1, EN 60335-2-41.
Component Material
Pump casing
Cast iron GJL 200 EN 1561 Special features on request
Lantern bracket - Other voltages.
Impeller Cast iron GJL 200 EN 1561 - Protection IP 55.
- Frequency 60 Hz
(Brass P-Cu Zn Pb 2 EN 1982 for NR-NR4 32..., 40..., 50/200)
- Special mechanical seal.
Shaft Chrome-nickel steel AISI 303 - Higher or lower liquid or ambient temperatures.
(Chrome steel AISI 430 from 3 kW to 18,5 kW) - Motor suitable for operation with frequency converter up to
Valve Chrome-nickel steel AISI 304 - NBR 0,55 kW for NR4 and up to 0,75 kW for NR.
Mecanical seal Carbon - Ceramic - NBR
Counterflanges Steel Fe 42 UNI 7070
95
NR(D) EI, NR4 EI In-line Pumps
The NR(D) EI, NR4 EI, pumps are available with power from 0,25 kW up to 18,5 kW, the pumps are equipped with I-MAT installed on
board which allows to realize a variable-speed system extremely compact and efficient, ideal in applications of water supply and in the
distribution of hot and cold water.
The pump is equipped with transducers suitable for operation and is already programmed at the factory.
Advantages
- Energy saving
- Compact design
- Easy to use
- Programmable to suit the system requirements
- Reliability
Costruction
The system comprises of:
- Pump
- Induction motor (2 for NRD EI)
- I-MAT Frequency converter (2 for NRD EI)
- Motor adapter for the motor mounting of the frequency converter (2 for NRD EI)
- Connection cable between frequency converter and induction motor
- Transducers
- Communication cable for cascade mode for NRD EI
- 2 Cascade mode expansion board for NRD EI
Main features
Rated motor power output from 0,25 kW to 18,5 kW
Control range from 1750 to 2900 rpm (2-pole)
Control range from 870 to 1450 rpm (4-pole)
Protection against dry running
Protection against operations with closed valve ports
Protection against system leakages
Protection against overcurrent in the motor
Protection agains overvoltage and undervoltage of the power supply
Protection against current unbalances between phases
Operating modes
H
Constant pressure mode
with pressure transducer +
-
In this mode, the system maintains the preset pressure when the flow required by
the installation changes.
Q
H
Proportional pressure mode
with pressure transducer +
-
In this mode the system changes the working pressure according to the required
flow rate.
H
Constant flow mode
with flow meter
-
+
In this mode the system maintains a constant flow rate value in a point of the instal-
lation according to the required pressure.
Q
H
Fixed speed mode
with setting of the speed preferential rotation. max
+
-
In this mode, by changing the working frequency, you may choose any operational
curve included within the working range. min
In this mode the system keeps the temperature constant inside a system by chan-
ging the speed of the pump.
96
NR(D), NR4 In-line Pumps
Coverage chart
100 50
NR n ≈ 2900 rpm 40 NR4 n ≈ 1450 rpm
H
m NR 50/250
30
NR 65/250
50
NR 32/200 NR 50/200 NR 65/200 20
40
NR 40/200 NR4 50/250
H NR4 65/250
30 m
NR 32/160 NR 40/160 NR 65/160
NR4 32/200 NR4
NR 50/160 10 50/200 NR4 125
20 NR4
40/200 NR4 65/200
5 2
3 4 5 6 3 10 15 20 30 40 50 100 1 3 2 3 4 5 10 20 30 40 50 100
50 100
Qm /h
l/min 200 300 400 500 1000 1500 20
Qm /h
l/min 40 50 100 150 200 300 400 500 1000 1500
50 50
NRD n ≈ 2900 rpm NRD n ≈ 2900 rpm
40 40
30 30
20 20
10 10
5 5
4 4
10 3 20 30 40 50 60 70 80 20 30 3 40 50 100 150
100
Qm /h
l/min 300 400 500 1000 400 500
Q m /h
l/min 1000 1500
* Single operation
** Parallel operation
97
NR In-line Pumps
A A A kW kW HP l/min 0 100 110 125 140 160 180 200 220 250 280 315
NR 50D/A 2,3 1,3 NRM 50D/A 3,6 0,72 0,45 0,6 H 11,6 11 10,8 10,5 10,2 9,5 8,5 7 6
NR 50C/B 3,7 2,2 NRM 50C/A 5,7 1,13 0,75 1 m 16,2 16 15,9 15,8 15,7 15,3 14,6 14 13 11 9 5,5
Q
3~ 230V 400V
P2 m3/h 0 2,4 3 3,6 4,8 6 6,6 7,5 8,4 9,6 10,8 12 13,2 15 16,8
A A kW HP l/min 0 40 50 60 80 100 110 125 140 160 180 200 220 250 280
NR 32/160B/A 4,6 2,7 1,1 1,5 28,1 27,9 27,6 27,3 26,5 25,6 25,1 24,3 23,4 21,9 20
NR 32/160A/A 7,5 4,3 1,5 2 H 36,8 36,3 36,1 35,7 35 34,3 33,8 33,2 32,4 31,2 29,7
NR 32/200B/A 9,2 5,3 2,2 3 m 42,5 41,6 41,3 40,6 39,8 39,3 38,5 37,7 36,5 35,1 33,4
NR 32/200A 11,5 6,6 3 4 51,2 49,7 49,5 48,9 48,2 47,9 47,2 46,5 45,4 44,2 42,8 41,2 37,9
NR 32/200S/A 9,4 4 5,5 58 57,4 57,2 56,7 56,1 55,8 55,1 54,4 53,3 52 50,5 48,8 45,9 42,6
Q
3~ 230V 400V
P2 m3/h 0 6,6 7,5 8,4 9,6 10,8 12 13,2 15 16,8 18,9 21 24
A A kW HP l/min 0 110 125 140 160 180 200 220 250 280 315 350 400
NR 40/125C 4 2,3 0,75 1 15,5 15,7 15,5 15,3 14,8 14,3 13,6 12,9 11,6 10,2 8,1 5,8
NR 40/125B/A 4,6 2,7 1,1 1,5 19,5 19,8 19,6 19,4 19,0 18,5 18,0 17,5 16,5 15,2 13,6 11,6 8,5
NR 40/125A/A 7,5 4,3 1,5 2 23,3 23,7 23,7 23,6 23,4 23,1 22,8 22,4 21,7 20,6 19,1 17,3 14,2
NR 40/160B/A 7,5 4,3 1,5 2 H 26,1 25,7 25,4 25,1 24,6 24,0 23,3 22,6 21,4 19,7 17,3 14,4 9,9
NR 40/160A/A 9,2 5,3 2,2 3 m 33,6 32,9 32,6 32,3 31,8 31,3 30,6 29,9 28,7 27,2 25,2 23,1 19,4
NR 40/200B 11,5 6,6 3 4 41,9 40,2 39,7 39,2 38,5 37,6 36,7 35,7 33,8 31,0 26,9 22,0
NR 40/200A/A 9,6 4 5,5 52,4 49,6 49,1 48,5 47,6 46,7 45,7 44,7 43,0 41,2 38,6 34,8
Q
3~ 230V 400V
P2 m3/h 0 15 16,8 18,9 21 24 27 30 33 37,8 39 42 45
A A kW HP l/min 0 250 280 315 350 400 450 500 550 630 650 700 750
NR 50/125F/A 4,6 2,7 1,1 1,5 14,9 13,8 13,4 12,8 12,1 11 9,9 8,4 6,9
NR 50/125C/A 7,5 4,3 1,5 2 17,7 17,4 17 16,5 16 15 13,9 12,6 11,3 9 8,3
NR 50/125A/B 9,2 5,3 2,2 3 22,2 21,7 21,4 21 20,6 19,8 18,8 17,5 16,3 14,1 13,5 12
NR 50/160C/B 9,2 5,3 2,2 3 23,1 21,9 21,4 20,6 19,9 18,6 17,3 15,6 13,8 10,8 10
NR 50/160B/A 11,5 6,6 3 4 28,6 27,9 27,4 26,7 26 24,6 23,1 21,3 19,7 16,6 15,7 13,6
NR 50/160A/B 9,6 4 5,5 H 36,6 35,5 35,1 34,5 33,7 32,7 31,2 29,4 27,5 24,3 23,4 21,3 19,1
NR 50/200D/B 9,6 4 5,5 m
41,8 37,8 36,8 35,7 34,5 32,4 30,1 27,6 24,9
NR 50/200B/A 10,8 5,5 7,5 50,9 48,5 47,7 46,8 45,7 43,9 41,7 39,2 36,5
NR 50/200A/A 14,3 7,5 10 56,7 54,9 54,3 53,4 52,4 50,7 48,9 46,5 44,1 39,7 38,8
NR 50/250C/B 18,5 9,2 12,5 61,2 58,8 58 57,3 56,5 55 53,2 51,1 48,9 44,8 43,1 39,4
NR 50/250B/B 21,5 11 15 69,4 67 66,4 65,5 64,8 63,2 61,5 59,6 57,7 53,8 52,6 50
NR 50/250A/B 27,3 15 20 87 84,6 84,1 83,2 82,3 80,7 78,8 76,9 74,3 69,8 68,4 65,2
Q
3~ 230V 400V
P2 m3/h 0 21 24 27 30 33 37,8 42 48 54 60 66 69 72
A A kW HP l/min 0 350 400 450 500 550 630 700 800 900 1000 1100 1150 1200
NR 65/125F/B 9,2 5,3 2,2 3 16,5 16 15,7 15,3 14,8 14,3 13,5 12,5 11,1 9,5 7,3 5,3
NR 65/125D/A 11,5 6,6 3 4 21,1 20,2 19,9 19,6 19,2 18,7 17,9 16,9 15,2 13,3 11,3 9,1
NR 65/125A/B 9,6 4 5,5 25 24,4 24,1 23,8 23,4 23 22,2 21,4 19,8 18 15,9 13,7 12,4
NR 65/125S/B 9,6 4 5,5 27,2 26,3 26 25,7 25,4 25 24,3 23,6 22,1 20,3 18,3 16,1 14,7
NR 65/160B/A 10,8 5,5 7,5 31,9 32 31,7 31,4 30,9 30,4 29,5 28,6 26,8 24,8 22,2 19,7 18,3 16,7
NR 65/160A/A 14,3 7,5 10 H 39 39,3 39 38,7 38,3 37,9 36,9 36,1 34,7 32,9 30,6 28,1 26,7 25,3
NR 65/200B/B 18,5 9,2 12,5 m
47,1 46,7 45,9 45,1 44,4 43,6 42 40,5 37,9 35,3 32,4 28,3
NR 65/200A/B 21,5 11 15 54,2 53,3 52,8 52,3 51,5 50,7 49,2 47,5 45,1 41,9 38,1 34,5
NR 65/200S/B 27,3 15 20 60,4 60,5 60,2 59,6 59 58 56,3 54,5 52,2 49,5 46,5 42,7
NR 65/250C/B 21,5 11 15 54,6 54,8 54,2 53,5 52,8 52 50,5 48,9 46,3 43,5 40,6 37,3
NR 65/250B/B 27,3 15 20 67,1 67,2 66,7 66 65,1 64,3 62,8 61,3 58,6 55,8 52,9 49,7
NR 65/250A/C 34 18,5 25 78,5 78,5 77,8 77,3 76,7 76 74,8 73,6 71,1 68,4 65,5 62,2
P1 Max. power input. P2 Rated motor power output. Tolerances according to UNI EN ISO 9906:2012
98
NR4 In-line Pumps
A A A kW kW HP l/min 0 33 67 100 133 167 200 233 267 300 333 417
NR4 50C/A 1,35 0,75 NR4M 50C/A 2,1 0,27 0,25 0,34 3,9 3,9 3,8 3,3 2,5
NR4 50B/A 1,35 0,75 NR4M 50B/A 2,1 0,29 0,25 0,34 4,7 4,7 4,6 4,3 3,5 2,3
NR4 50A/A 1,35 0,75 NR4M 50A/A 2,1 0,33 0,25 0,34 H 5,6 5,6 5,5 5,2 4,5 3,5 2
NR4 65C/A 1,35 0,75 NR4M 65C/A 2,1 0,31 0,25 0,34 m 3,8 3,8 3,7 3,5 3,1 2,6 1,9
NR4 65B/A 2,1 1,2 0,37 0,5 4,7 4,7 4,6 4,5 4,2 3,8 3,2 2,5
NR4 65A/A 2,1 1,2 0,37 0,5 5,6 5,6 5,5 5,3 5 4,6 4,1 3,5 2,7
3~ 230V 400V Q
P2 m3/h 0 1 1,2 1,5 1,89 2,4 3 3,6 4,2 4,8 5,4 6 6,6 7,5 8,4 9,6
3~ 230V 400V Q
P2 m3/h 0 2,4 3 3,6 4,8 5,4 6 7,5 8,4 9,6 10,8 12 13,2 15
3~ 230V 400V Q
P2 m3/h 0 5,4 6 7,5 8,4 9,6 10,8 12 13,2 15 16,8 18,9 21 24 27 30
A A kW HP l/min 0 90 100 125 140 160 180 200 220 250 280 315 350 400 450 500
NR4 50/160C 1,65 0,95 0,37 0,5 5,9 5,9 5,8 5,7 5,6 5,4 5,2 5 4,7 4,2 3,7 3,1 2,3
NR4 50/160B 2,6 1,5 0,55 0,75 7,3 7,4 7,4 7,2 7,1 6,9 6,7 6,4 6,2 5,7 5,2 4,5 3,8 2,5
NR4 50/160A/B 3,3 1,9 0,75 1 9,2 9,2 9,2 9,1 9 8,9 8,7 8,4 8,2 7,6 7,1 6,4 5,6 4,4 3,1
NR4 50/200B/B 5 2,9 1,1 1,5 H 12,8 12,6 12,5 12,3 12,1 11,9 11,5 11,2 10,7 10 9,2 8,2 7,1 5,2
NR4 50/200A/B 5 2,9 1,1 1,5 m 14,3 14,1 14 13,9 13,7 13,5 13,2 12,8 12,4 11,7 11 10 8,8 7,3
NR4 50/250C/B 6 3,5 1,5 2 17,1 17 16,9 16,6 16,4 16,1 15,9 15,6 15,2 14,6 13,9 12,8 11,3 8,5 5,3
NR4 50/250B/B 8,6 5 2,2 3 21 20,9 20,8 20,5 20,3 20 19,7 19,4 19 18,4 17,8 16,8 15,6 13,8 11,7 8,5
NR4 50/250A/A 11,1 6,4 3 4 22 21,9 21,9 21,8 21,6 21,4 21,1 20,9 20,5 19,9 19,2 18,3 17,2 15,3 13,4 11
3~ 230V 400V Q
P2 m3/h 0 10,8 12 13,2 15 16,8 18,9 21 24 27 30 33 37,5 42 48
A A kW HP l/min 0 180 200 220 250 280 315 350 400 450 500 550 630 700 800
NR4 65/125F 1,65 0,95 0,37 0,5 4,1 3,9 3,85 3,8 3,6 3,5 3,3 3 2,6 2,1 1,6 1
NR4 65/125D 2,6 1,5 0,55 0,75 5,3 5 5 4,9 4,8 4,7 4,5 4,3 3,9 3,4 2,9 2,4 1,5
NR4 65/125A/B 3,3 1,9 0,75 1 6,3 6,2 6,1 6 5,9 5,8 5,7 5,5 5,1 4,6 4,1 3,5 2,6 1,5
NR4 65/125S/B 3,3 1,9 0,75 1 6,8 6,6 6,6 6,5 6,4 6,3 6,1 5,9 5,6 5,1 4,6 4,1 3,2 2,1
NR4 65/160B/B 5 2,9 1,1 1,5 8,2 8,2 8,2 8,1 8 7,9 7,7 7,5 7,1 6,6 6 5,4 4,3 3,2
NR4 65/160A/B 5 2,9 1,1 1,5 H 9,7 9,6 9,5 9,5 9,4 9,2 9 8,8 8,5 8 7,4 6,8 5,8 4,7 3
NR4 65/200C/B 5 2,9 1,1 1,5 m 11,4 11,3 11,2 11,1 10,8 10,6 10,3 9,9 9,4 8,7 7,9 7 5,3 3,4
NR4 65/200B/B 6 3,5 1,5 2 13,3 13,1 13 12,9 12,7 12,4 12,1 11,8 11,2 10,5 9,7 8,9 7,2 5,4
NR4 65/200A/B 8,6 5 2,2 3 14,5 14,6 14,5 14,4 14,2 13,9 13,6 13,2 12,7 12 11,3 10,5 9 7,2
NR4 65/250D/B 8,6 5 2,2 3 13,7 13,9 13,8 13,8 13,6 13,4 13,1 12,8 12,3 11,6 10,9 10,1 8,6 7,2
NR4 65/250C/B 8,6 5 2,2 3 17,1 17,3 17,2 17,2 16,9 16,7 16,3 16 15,4 14,7 13,9 13 11,4 10
NR4 65/250B/A 11,1 6,4 3 4 19,9 20,1 20 20 19,8 19,6 19,3 19 18,4 17,7 16,9 16,1 14,6 13,2 10,8*
NR4 65/250A/A 14,4 8,3 4 5,5 21,4 21,6 21,5 21,4 21,3 21,1 20,8 20,5 19,9 19,2 18,4 17,6 16,1 14,7 12,2*
3~ 230V 400V P2 Q
m3/h 0 20 25 30 35 40 50 60 70 80 90 100 110
A A kW HP l/min 0 333 417 500 583 667 833 1000 1167 1333 1500 1667 1833
NR4 100C/B 5 2,9 1,1 1,5 6,6 6,6 6,4 6,3 6 5,6 4,6 3,3
NR4 100B/B 5 2,9 1,1 1,5 7,5 7,5 7,4 7,2 7 6,6 5,6 4,4
NR4 100A/B 6 3,5 1,5 2 H 9 9 8,9 8,8 8,6 8,3 7,4 6,2 4,8
NR4 125C/B 8,6 5 2,2 3 m 10,2 10,2 10,1 10 9,6 9 8,2 7,1 5,7 4
NR4 125B/A 11,1 6,4 3 4 12 12 11,9 11,8 11,6 11 10,4 9,4 8,2 6,7 5,1
NR4 125A/A 14,4 8,3 4 5,5 13,6 13,6 13,5 13,4 13,2 12,9 12,3 11,4 10,3 8,8 7,2
P1 Max. power input. P2 Rated motor power output. Tolerances according to UNI EN ISO 9906:2012
99
NRD In-line Pumps
Q
3~ 230V 400V
P2 m 3/h 0 15 16,8 18,9 21 24 27 30 33 37,8 39 42 45
A A kW HP l/min 0 250 280 315 350 400 450 500 550 630 650 700 750
NRD 50-125F 4,6 2,7 1,1 1,5 13,7 13,2 12,7 12,0 11,2 9,9 8,5 6,8 4,8
NRD 50-125C 7,5 4,3 1,5 2 17,8 17,8 17,4 16,8 16,0 14,8 13,3 11,7 9,9 6,8 5,9
NRD 50-125A 9,2 5,3 2,2 3 H 20,8 21,2 20,9 20,5 19,9 18,7 17,4 15,8 14,1 11,1 10,4 8,3
NRD 50-160C 9,2 5,3 2,2 3 m 23,4 22,9 22,4 21,7 20,9 19,4 17,7 15,7 13,4 9,1 7,8
NRD 50-160B 11,5 6,6 3 4 25,6 25,0 24,6 24,0 23,3 22,0 20,4 18,5 16,2 11,9 10,7 7,5
NRD 50-160A 9,6 4 5,5 34,0 34,6 34,3 33,8 33,2 32,0 30,5 28,7 26,7 22,8 21,7 18,8 15,6
Q
3~ 230V 400V
P2 m 3/h 0 21 24 27 30 33 37,8 42 48 54 60 66 69
A A kW HP l/min 0 350 400 450 500 550 630 700 800 900 1000 1100 1150
NRD 65/125F 9,2 5,3 2,2 3 16,2 14,9 14,4 13,8 13,2 12,5 11,3 10,1 8,2 6,1 3,9
NRD 65/125D 11,5 6,6 3 4 H 20,4 19,1 18,6 18,1 17,5 16,9 15,7 14,4 12,4 10,0 7,2 4,3
m
NRD 65/125A 9,6 4 5,5 25,3 25,0 24,7 24,3 23,8 23,2 22,1 21,0 19,1 16,9 14,3 11,5 9,9
Parallel operation
Q
3~ 230V 400V
P2 m 3/h 0 30 33 37,8 42 48 54 60 66 75 84 90
A A kW HP l/min 0 500 550 630 700 800 900 1000 1100 1250 1400 1500
NRD 50-125F 4,6 x2 2,7 x2 1,1 x2 1,5 x2 13,7 13,3 12,9 12,0 11,1 9,7 8,1
NRD 50-125C 7,5 x2 4,3 x2 1,5 x2 2 x2 17,8 17,7 17,4 16,7 15,9 14,5 12,9 11,1 9,3
NRD 50-125A 9,2 x2 5,3 x2 2,2 x2 3 x2 H 20,8 21,0 20,8 20,3 19,7 18,5 17,1 15,4 13,5 10,8
NRD 50-160C 9,2 x2 5,3 x2 2,2 x2 3 x2 m 23,4 22,9 22,5 21,7 20,8 19,2 17,2 15,0 12,3
NRD 50-160B 11,5 x2 6,6 x2 3 x2 4 x2 25,6 25,0 24,6 23,9 23,1 21,6 19,9 17,7 15,1 10,3
NRD 50-160A 9,6 x2 4 x2 5,5 x2 34,0 34,2 34,0 33,5 32,9 31,7 30,2 28,2 25,9 21,8 17,0 13,2
Q
3~ 230V 400V
P2 m 3/h 0 42 48 54 60 66 75 84 96 108 120
A A kW HP l/min 0 700 800 900 1000 1100 1250 1400 1600 1800 2000
NRD 65/125F 9,2 x2 5,3 x2 2,2 x2 3 x2 16,2 15,2 14,8 14,4 13,8 13,0 11,7 10,2 7,9 5,2
NRD 65/125D 11,5 x2 6,6 x2 3 x2 4 x2 H 20,4 19,8 19,4 18,9 18,4 17,7 16,5 15,0 12,7 10,0
m
NRD 65/125A 9,6 x2 4 x2 5,5 x2 25,3 24,9 24,6 24,2 23,7 23,1 22,0 20,7 18,5 16,0 13,1
P1 Max. power input. P2 Rated motor power output. Tolerances according to UNI EN ISO 9906:2012
100
NR In-line Pumps
0 U.S. g.p.m. 20 40 60 80
18
C Ø 116 50 55
60 62
15 η 64%
NR 50 50
62
60 40
D Ø 103
55
10
Hm
50
H ft
30
20
5
10
0 0
3
0 Q m /h 5 10 15 20
0 l/min 100 200 300
0 l/s 1 2 3 4 5
1.0
C 1.2
1.0
P kW
0.8
P HP
0.5
D 0.6
0.4
0.2
0 0
0 5 10 15 72.115 20
Q m3/h
0 U.S.g.p.m. 10 20 30 40 50 0 U.S.g.p.m. 20 30 40 50 60 70
40 60
S ∅ 200
A ∅ 161,5 NR 32/160 120
NR 32/200 180
50 A ∅ 190 160
30 100
B ∅ 144
140
80 40 B ∅ 178
m
120
H ft
H
20
H
60
30 100 H ft
40
80
10
20
20 60
40
0 0 10
0 Q m 3/h 2,5 5 7,5 10 12,5 0 Q m 3/h 5 10 15 20
0 Q l/min 50 100 150 200 0 Q l/min 100 150 200 250 300
5
3 S 6
2 4
A 5
P kW
1,5
P kW
2
P HP
3 4
P HP
B A
1 2 3
B
1 2
0,5 1 1
0 0 0 0
80 80
B A S
A
60 60
η%
B
η%
40 40
20 20
0 0
8 8
NPSH m
20
NPSH m
6 6 20
NPSH ft
NPSH ft
4 4
10 10
2 2
0 0 0 0
0 Q m 3/h 2,5 5 7,5 10 12,5 0 Q m 3/h 5 10 15 20
101
NR In-line Pumps
Hm
40 20
60
H ft
H ft
10
30
15 50
20 40
5
10
10 30
20
0 0 5
0 Q m 3/h 5 10 15 20 25 0 Q m 3/h 5 10 15 20 25
0 Q l/min 100 200 300 400 0 Q l/min 100 200 300 400
2 3 4
A A
1,5 2 3
B 2
P kW
P HP
P kW
P HP
1 B
2
C 1 1
0,5 1
0 0 0 0
80 80
70 70
A A
60
η%
η%
60 B
B 50
50
C 40
40 30
8 8
NPSH m
6 20
NPSH m
6 20
NPSH ft
NPSH ft
4 4
10 10
2 2
0 0 0 0
0 Q m 3/h 5 10 15 20 25 0 Q m 3/h 5 10 15 20 25
0 U.S.g.p.m. 25 50 75 100
60
A ∅196
NR 40/200 180
50
160
B ∅ 178 140
40
120
Hm
100
H ft
30
80
20
60
40
10
0 Q m 3/h 5 10 15 20 25
P HP
2
2
1
0 0
80
70
60
η%
A
50
B
40
30
8
NPSH m
6 20
NPSH ft
4
10
2
0 0
0 Q m 3/h 5 10 15 20 25
102
NR In-line Pumps
15 50 80
m
F ∅115 C ∅ 137
H ft
Hm
H
40 20
60
H ft
10
30
40
20 10
5
20
10
0 0 0 0
0 Q m 3/h 10 20 30 40 50 0 Q m 3/h 10 20 30 40 50
0 Q l/min 200 400 600 800 0 Q l/min 200 400 600 800
2,5 5
A 3 A 6
2 4
5
1,5 C 2
P kW 3 4
P kW
B
P HP
P HP
1 F 2 C 3
1 2
0,5 1 1
0 0 0 0
80 80
A
60 60
C A
F B
η%
η%
40 40 C
20 20
0 0
8 8
NPSH m
NPSH m
6 20 6 20
NPSH ft
NPSH ft
4 4
10 10
2 2
0 0 0 0
0 Q m 3/h 10 20 30 40 50 0 Q m 3/h 10 20 30 40 50
120
H ft
C ∅ 215
H
60 200
H
30 100
H ft
150
80
40
20
60
100
40
10 20
0 Q m 3/h 10 15 20 25 30 35 40 0 Q m 3/h 10 20 30 40 50
0 Q l/min 200 300 400 500 600 0 Q l/min 200 400 600 800
10 16
12 A 20
8 A 12
10 15
B
P kW
P kW
6 8
P HP
P HP
B
B
C
6 8 10
4 D
D
4
2 4 5
2
0 0 0 0
80 80
60 60 A
B
C
η%
η%
40 40
20 20
0 0
8 8
NPSH m
20
NPSH m
6 20 6
NPSH ft
NPSH ft
4 4
10 10
2 2
0 0 0 0
0 Q m 3/h 10 15 20 25 30 35 40 0 Q m 3/h 10 20 30 40 50
103
NR In-line Pumps
m
60 80
F ∅ 124
H
m
50 20
H
60
H ft
H ft
40
10
30 40
10
20
20
10
0 0 0 0
0 Q m 3/h 20 30 40 50 60 70 80 0 Q m 3/h 20 30 40 50 60 70 80
0 Q l/min 400 600 800 1000 1200 0 Q l/min 400 600 800 1000 1200
5 8
6 A 10
4 S
A 5 6 8
B
P kW
P kW
3 4
P HP
P HP
D 6
3 4
2 F 4
2 2
1 1 2
0 0 0 0
80 80
S A
60 60
D A B
η%
η%
40 F 40
20 20
0 0
10 10
30 30
8 8
NPSH m
NPSH m
NPSH ft
NPSH ft
6 20 6 20
4 4
10 10
2 2
0 0 0 0
0 Q m 3/h 20 30 40 50 60 70 80 0 Q m 3/h 20 30 40 50 60 70 80
0 U.S.g.p.m. 100 150 200 250 300 350 0 U.S.g.p.m. 100 150 200 250 300 350
70 90
220
280
60
S ∅ 209 NR 65/200 200 80 A ∅ 245 NR 65/250 260
A ∅ 200
H ft
180
50 70 B ∅ 229
B ∅ 188 160
220
140
m
40 60 200
H
H
H ft
C ∅ 209
180
30 100 50 160
50
140
20 40
60
120
40
10 30 100
0 Q m 3/h 20 30 40 50 60 70 80 0 Q m 3/h 20 30 40 50 60 70 80
0 Q l/min 400 600 800 1000 1200 0 Q l/min 400 600 800 1000 1200
16 20
20 A 24
12 S 16 B
16 20
A
P kW
P kW
12 16
P HP
P HP
8 B 12 C
8 12
8
4 8
4 4 4
0 0 0 0
80 80
S
60 A 60
B
η%
η%
40 40
20 20
0 0
8 8
NPSH m
NPSH m
6 20 6 20
NPSH ft
NPSH ft
4 4
10 10
2 2
0 0 0 0
0 Q m 3/h 20 30 40 50 60 70 80 0 Q m 3/h 20 30 40 50 60 70 80
104
NR4 In-line Pumps
Hm
Hm
60 65 12
H ft
H ft
4 C Ø 110
55 60
12 3 10
50
8
3 10
2
6
8
4
2 1
0 Q m3/h 2 4 6 8 10 12 0 Q m3/h 5 10 15 20
0 l/min 50 100 150 200 0 l/min 50 100 150 200 250 300
P HP
P HP
0.1 C C 0.2
0.1 0.1
0.1
0 0 0 0
0 0 Q m3/h 5 10 15 20
Q m3/h 2 4 6 8 10 12 72.079 72.111
105
NR4 In-line Pumps
m
H ft
H ft
5 10
H
H
15 30
4 8
3 10 6 20
2 4
5 10
1 2
0 0 0 0
0 Q m 3/h 2,5 5 7,5 0 Q m3/h 2,5 5 7,5 10
P kW
P HP
P HP
0,2 0,4 B
B C
0,2 0,4
0,1 0,2
0 0 0 0
80 80
60 60
A
A
η%
η%
40 40
B C B
20 20
0 0
6 8
5
NPSH m
NPSH m
15 6 15
NPSH ft
NPSH ft
4
3 10 4
2 10
5 2
1
0 0 0 0
0 Q m 3/h 2,5 10 7,5 0 Q m 3/h 2,5 5 7,5 10
0 U.S.g.p.m. 20 30 40 50 60 0 U.S.g.p.m. 20 30 40 50 60
10 20
A ∅ 164 30 60
9 18
NR4 40/160 NR4 40/200
8 16
25 50
B ∅ 149 A ∅ 204
7 14
6 20 12 B ∅ 195 40
m
m
H ft
H ft
5 10
H
15 30
4 8
3 10 6 20
2 4
5 10
1 2
0 0 0 0
0 Q m 3/h 2,5 5 7,5 10 12,5 15 0 Q m 3/h 2,5 5 7,5 10 12,5 15
0 Q l/min 50 100 150 200 250 0 Q l/min 50 100 150 200 250
0,4 0,8
A A
0,3 0,4 0,6 0,8
B
P kW
P kW
P HP
P HP
0,2 0,4 B
0,2 0,4
0,1 0,2
0 0 0 0
80 80
60 60
A
η%
η%
40 40 A
B
20 20 B
0 0
5 10
15 30
4 8
NPSH m
NPSH m
NPSH ft
NPSH ft
3 10 6 15
2 4
5 10
1 2
0 0 0 0
0 Q m 3/h 2,5 5 7,5 10 12,5 15 0 Q m 3/h 2,5 5 7,5 10 12,5 15
106
NR4 In-line Pumps
20 10
6 C ∅ 137 30
m
m
H ft
H ft
5 8
H
H
15
4
6 20
3 10
4
2 10
5
2
1
0 0 0 0
0 Q m 3/h 5 10 15 20 25 30 0 Q m 3/h 5 10 15 20 25 30
0 Q l/min 100 200 300 400 500 0 Q l/min 100 200 300 400 500
0,7 1,4
0,6 A 0,8 1,6
0,5 1 A
B 0,6 1,2
P kW
P kW
P HP
P HP
0,4 B
0,3 C 0,4 0,8
0,2 0,4
0,2 0,4
0,1
0 0 0 0
80 80
60 60
A
A
η%
η%
40 C B 40 B
20 20
0 0
10 5
30 15
8 4
NPSH m
NPSH m
NPSH ft
NPSH ft
6 20 3 10
4 2
10 5
2 1
0 0 0 0
0 Q m 3/h 5 10 15 20 25 30 0 Q m 3/h 5 10 15 20 25 30
15 50
m
H ft
H
40
10
30
20
5
10
0 0
0 Q m 3/h 5 10 15 20 25 30
P HP
B
C 1,6
0,8
0,8
0 0
80
60
A
η%
40
B
20 C
0
8
NPSH m
6 20
NPSH ft
4
10
2
0 0
0 Q m 3/h 5 10 15 20 25 30
107
NR4 In-line Pumps
m
F ∅ 124
H ft
H ft
4 5
H
H
15
4
3 10
3 10
2
5 2
5
1
1
0 0 0 0
0 Q m 3/h 10 20 30 40 50 0 Q m 3/h 10 20 30 40 50
0 Q l/min 200 400 600 800 0 Q l/min 200 400 600 800
0,6 0,8 1
S A 1,2
A 0,8
0,6 B 1
0,4
P kW
D P kW 0,6 0,8
P HP
P HP
F 0,4 0,6
0,4
0,2 0,4
0,2 0,2 0,2
0 0 0 0
80 80
60 60
S B A
η%
η%
40 F D A 40
20 20
0 0
8 10
30
8
NPSH m
NPSH m
6 20
NPSH ft
NPSH ft
6 20
4
10 4
10
2 2
0 0 0 0
0 Q m 3/h 10 20 30 40 50 0 Q m 3/h 10 20 30 40 50
12 C ∅ 188 40 15 50
D ∅ 209
m
m
H ft
H ft
10
H
H
40
30
8 10
30
6 20
20
4 5
10
10
2
0 0 0 0
0 Q m 3/h 10 20 30 40 50 0 Q m 3/h 10 20 30 40 50
0 Q l/min 200 400 600 800 0 Q l/min 200 400 600 800
2 4
2,4 4,8
1,6 A 3,2
2 A 4
B B
P kW
P kW
C 1,2 C 2,4
0,8 1,6 D
0,8 1,6
0,4 0,4 0,8 0,8
0 0 0 0
80 80
60 60 A
A
C-D B
η%
η%
40 B 40
C
20 20
0 0
5 10
15 30
4 8
NPSH m
NPSH m
NPSH ft
NPSH ft
3 10 6 20
2 4
5 10
1 2
0 0 0 0
0 Q m 3/h 10 20 30 40 50 0 Q m 3/h 10 20 30 40 50
108
NR4 In-line Pumps
0 U.S. g.p.m. 100 200 300 0 U.S. g.p.m. 100 200 300 400 500
10 14
60 65 45
A Ø 210 68 70
9
A Ø 174 60 65 67.5
70 NR4 100 30 72 NR4 125
72 B Ø 200 40
74
12
8
B Ø 160 η 74% 72
C Ø 188 η 74% 35
7 C Ø 152 72 10 70
70 68
Hm
Hm
30
H ft
20
H ft
6 67.5
65 65
8
5 25
4
60 6 20
60
3 10
15
2 4
3 0 m /h3 20 40 60 80 100 120
0 m /h 10 20 30 40 50 60 70
Q Q
0 l/min 200 400 600 800 1000 1200 0 l/min 500 1000 1500 2000
0 l/s 4 6 8 10 12 14 16 18 20 0 l/s 10 20 30
1.6 4
A 2 A 5
3 B 4
B
1.0
P kW
P kW
P HP
P HP
C C 3
2
1
2
1
1
0 0 0 0
72.113 72.114
0 Q m3/h 10 20 30 40 50 60 70 0 Q m3/h 20 40 60 80 100 120
109
NRD In-line Pumps
m
15 F ∅ 110 50 80
H
C∅137
m
40 20
H
60
H ft
H ft
10
30
40
20 10
5
20
10
0 0 0 0
0 Q m 3/h 20 30 40 50 60 70 80 0 Q m3/h 20 30 40 50 60 70 80 90 100
0 Q l/min 400 600 800 1000 1200 0 Q l/min 400 600 800 1000 1200 1400 1600
5 12
6 8 A
4 A 10
5
C 6 B 8
P kW
P kW
3 4
P HP
P HP
F 3 4 C 6
2 A
A 4
C 2 B
1 2 C
F 1 2
0 0 0 0
80 80
60 60
F C A
η%
η%
40 A 40 A C
F C A
B
C B
20 20
0 0
10 14
A 30 A
8 12 40
NPSH m
NPSH m
A 10
NPSH ft
NPSH ft
6 20
F 8 C
4 6 A 20
F 10 C
2 4
2
0 0 0 0
0 Q m 3/h 20 30 40 50 60 70 80 0 Q m3/h 20 30 40 50 60 70 80 90 100
90
A ∅ 146
NRD 65/125
80
D ∅ 133 70
20
60
F ∅ 120
m
50
H
H ft
40
10
30
20
10
0 0
0 Q m3/h 20 40 60 80 100 120
P HP
4 F
6
A 4
2 D
F 2
0 0
80
60
A A
D
η%
40
F
F
20 D
0
12
A
10
30
NPSH m
F
8
NPSH ft
6 A 20
F
4
10
2
0 0
0 Q m3/h 20 40 60 80 100 120
110
NR,NR4 In-line Pumps
mm
TYPE
DN a fM h1 h6 n2 m2 j1 Øb AD l1 l2 x kg
x
NR 50D/A-C/B 50 320 360 90 270 - - - 98 111 93 100 70 21,7-23,8
NR 32/160A/A-B/A 32 340 421 80 341 76 90 50 - 128 102 102 60 28,6-27
NR 32/200B 32 440 469 85 384 84 104 60 - 128 126 126 60 36,3
NR 32/200A/A-S/A 32 440 495 85 410 84 104 60 - 138 126 126 60 44-47
NR 40/125A/A-B/A-C 40 320 420 81 339 80 80 49 - 128 93 98 70 29,5-27,5-26,5
NR 40/160B/A 40 320 430 81 349 80 80 49 - 128 119 119 75 35,0
h6
DN
NR 65/200A/B 65 475 716 105 611 110 110 60 - 185 140 153 90 114
l2
NR 65/200S/B 65 475 741 105 636 110 110 60 - 185 140 153 90 142,5
NR 65/250C/B 65 475 722 105 567 110 110 60 - 185 175 175 90 134
NR 65/250B/B 65 475 747 105 642 110 110 60 - 185 175 175 90 155
a NR 65/250A/C 65 475 793 105 688 110 110 60 - 206 175 175 90 -
mm
TYPE
DN a fM h1 h6 n2 m2 j1 Øb AD l1 l2 x kg
NR4 50A/A-B/A-C/A 50 320 360 90 270 - - - 98 111 93 100 70 22-22-22
M16 NR4 65A/A-B/A-C/A 65 360 370 100 270 - - - 118 111 102 114 70 28-28-28
Øb NR4 100A/B-B/B-C/B 100 500 549 150 399 - - - 162 138 153 173 105 67-59-59
NR4 125C/B 125 600 589 170 419 - - - 194 138 172 195 120 91,5
3 fori M 10 x10 195 120 110-108
NR4 125A/A-B/A 125 600 608 160 438 - - - 194 160 172
NR4 32/160A-B 32 340 421 80 341 76 90 50 - 128 102 102 60 23-22,9
NR4 32/200B-C 32 440 429 85 344 84 104 60 - 128 126 126 60 30,8-29,2
n2
Holes
Installation
DN DG DK DE W
N° Ø
32 76 100 140 4 19 18
40 84 110 150 4 19 18
50 99 125 165 4 19 20
65 118 145 185 4 19 20
80 132 160 200 8 19 22
100 156 180 220 8 19 24
125 184 210 250 8 19 24
4.93.032.2
111
NR EI, NR4 EI In-line Pumps
mm
TYPE
DN a fM h1 h6 AD AG AR l1 l2 x kg
NR EI 50D/A-C/B 50 320 399 90 270 270 190 105 93 100 70 28-30,2
NR EI 32/160A/A-B/A 32 340 421 80 341 286 190 105 102 102 60 35-33,3
h6
NR EI 32/200B 32 440 469 85 384 286 210 118 126 126 60 43,8
NR EI 32/200A/A-S/A 32 440 495 85 410 294 210 118 126 126 60 51,5-54,5
fM
DN
4.93.101.2
NR EI 50/125A/B 50 340 477 90 387 286 210 118 96 115 75 43,6
NR EI 50/160C/B 50 340 480 90 390 286 210 118 120 128 75 49,1
40
NR EI 50/160A/B-B/A 50 340 506 90 416 294 210 118 120 128 75 59,3-56
NR EI 50/200D/B 50 440 516 100 416 294 210 118 140 140 80 67,2
a NR EI 50/200A/A-B/A 50 440 544 100 444 368 281 153 140 140 80 92-84,5
220 NR EI 50/250C/B 50 440 657 100 557 393 281 153 175 175 85 128,8
NR EI 50/250B/B 50 440 707 100 557 393 281 153 175 175 85 135,8
NR EI 50/250A/B 50 440 732 100 632 471 350 190 175 175 85 184,5
NR EI 65/125F/B 65 340 494 105 389 286 210 118 121 145 95 53,5
l1
NR EI 65/125S/B-A/B-D/A 65 340 520 105 415 294 210 118 121 145 95 63,6-63,6-62,1
220
NR EI 65/160A/A-B/A 65 340 552 105 447 368 281 153 121 142 95 88,8-82,3
NR EI 65/200B/B 65 475 666 105 561 368 281 153 140 153 90 122,8
l2
NR EI 65/200A/B 65 475 716 105 611 393 281 153 140 153 90 128,8
NR EI 65/200S/B 65 475 741 105 636 471 350 190 140 153 90 177,5
4 fori Ø14
AD
NR EI 65/250C/B 65 475 722 105 567 393 281 153 175 175 90 148,8
NR EI 65/250B/B 65 475 747 105 642 471 350 190 175 175 90 190
NR EI 65/250A/C 65 475 793 105 688 491 350 190 175 175 90 -
AR mm
AG TYPE
DN a fM h6 h2 AD AG AR l1 l2 x kg
NR4 EI 50A/A-B/A-C/A 50 320 399 90 270 270 190 105 93 100 70 28,4-28,4-28,4
NR4 EI 65A/A-B/A-C/A 65 360 409 100 270 270 190 105 102 114 70 34,4-34,4-34,4
Flanges PN 10, EN 1092-2 NR4 EI 100B/B-C/B 100 500 549 150 399 294 190 105 153 173 105 65,4-65,4
NR4 EI 100A/B 100 500 549 150 399 294 190 105 153 173 105 73,4
NR4 EI 125A/A-B/A-C/B 125 600 608 160 438 368 210 118 172 195 120 117,5-115,5-97,9
DG NR4 EI 32/160A-B 32 340 421 80 341 286 190 105 102 102 60 29,4-29,3
NR4 EI 32/200B-C 32 440 429 85 344 286 190 105 126 126 60 37,2-35,2
NR4 EI 32/200A/A 32 440 469 85 344 286 190 105 126 126 60 -
W DN NR4 EI 40/160A-B 40 320 430 81 349 286 190 105 119 119 75 37,9-37,4
DK NR4 EI 40/200B 40 440 430 81 349 286 190 105 140 140 75 45,9
DE NR4 EI 40/200A/A 40 440 470 81 349 286 190 105 140 140 75 49,4
4.93.094
NR4 EI 50/160B-C 50 340 440 90 350 286 190 105 120 128 75 41,9-39,9
mm NR4 EI 50/160A/B 50 340 480 90 350 286 190 105 120 128 75 43,9
NR4 EI 50/200A/B-B/B 50 440 516 100 416 294 190 105 140 140 80 62,4
Holes NR4 EI 50/250C/B 50 440 516 100 416 294 190 105 175 175 85 83,9
DN DG DK DE W
N° Ø NR4 EI 50/250A/A-B/B 50 440 545 100 445 368 210 118 175 175 85 101-86,4
32 76 100 140 4 19 18 NR4 EI 65/125D-F 65 340 454 105 349 286 190 105 121 145 95 45,4-43,4
NR4 EI 65/125S/B-A/B 65 340 494 105 349 286 190 105 121 145 95 48,4-48
40 84 110 150 4 19 18
NR4 EI 65/160A/B-B/B 65 340 504 105 399 294 190 105 121 142 95 49,1-48,9
50 99 125 165 4 19 20
NR4 EI 65/200C/B 65 475 536 105 431 294 190 105 140 153 90 58,4
65 118 145 185 4 19 20
NR4 EI 65/200B/B 65 475 536 105 431 294 190 105 140 153 90 66,4
80 132 160 200 8 19 22
NR4 EI 65/200A/B 65 475 552 105 447 368 210 118 175 175 90 70,9
100 156 180 220 8 19 24
NR4 EI 65/250C/B-D/B 65 475 555 105 450 365 210 118 175 175 90 81,9-81,9
125 184 210 250 8 19 24 555 105 450 368 210 118 175 175 90
NR4 EI 65/250A/A-B/A 65 475 105,5-92,5
112
NRD In-line Pumps
DG
fM
W DN
DK
DN
DN
DE
h1
4.93.094
mm
a j5
Holes
DN DG DK DE W
N° Ø
50 99 125 165 4 19 20
I1
mm
TYPE
DN a fM h1 h6 AD j5 l1 l2 kg
NRD 50/125C-F 50 340 433,5 90 343,5 130 310 278,5 278,5
I2
NRD 65/125A-D 65 340 514,5 105 409,5 139 310 303,5 303,5 106,3-99,3
DG
DN
DN
W DN
h1
DK
j3 j4 j5 j2 4.93.094 DE
a
mm
Holes
DN DG DK DE W
N° Ø
50 99 125 165 4 19 20
65 118 145 185 4 19 20
I1
mm
TYPE
DN a fM h1 h6 AD AG AR j1 j2 j3 j4 j5 l1 l2 kg
NRD EI 50/125C-F 50 340 433,5 90 343,5 284 190 105 243 269 269 243 310 278,5 278,5
NRD EI 50/125A 50 340 473,5 90 383,5 284 210 118 249 277 277 249 310 278,5 278,5
NRD EI 50/160C 50 340 473,5 90 383,5 284 210 118 249 277 277 249 310 291,5 291,5
I2
NRD EI 50/160A-B 50 340 499,5 90 409,5 293 210 118 256 283 283 256 310 291,5 291,5
NRD EI 65/125F 65 340 488,5 105 383,5 284 210 118 249 277 277 249 310 303,5 303,5 102,7
NRD EI 65/125A-D 65 340 514,5 105 409,5 293 210 118 256 283 283 256 310 303,5 303,5 121,3-114,3
AD
AG
AR
j1
113
NR,NR4 In-line Pumps
Features
Advanced hydraulics
Optimum impeller geometry provides maxi-
A Unique Design mum efficiency and excellent suction cha-
An innovative guard (patented) pre- racteristics.
vents contact with rotating parts,
providing protection to the end user
whilst allowing for inspection of the
mechanical seal.
Silent operation
Specially designed fluid ducts provide
very quiet operation
114
03/2021
Construction
Horizontal multi-stage close coupled pumps in chrome-nickel
stainless steel.
Compact and robust construction, without protruding flange
and with single-piece lantern bracket and base.
Single-piece barrel casing, with front suction port above
pumps axis and radial delivery at top.
Filling and draining plugs on the middle of the pump, accessi-
ble from any side (like the terminal box).
Version with frequency converter (on request)
Applications
For water supply.
For clean liquids, without abrasives, which are non-aggressive
for stainless steel (with suitable seal materials, on request).
Universal pump, for domestic use, for civil and industrial
applications, for garden use and irrigation.
Operating conditions
Liquid temperature from - 15 °C to + 110 °C.
Ambient temperature up to 40 °C.
Maximum permissible pressure in the pump casing: 8 bar.
Continuous duty.
Motor
2-pole induction motor, 50 Hz (n ≈ 2800 rpm).
MXH: three-phase 230/400 V ± 10% up to 3 kW;
400/690 V ± 10% from 3,7 to 4 kW.
Materials MXHM: single-phase 230 V ± 10%, with thermal protector.
Capacitor inside the terminal box.
Component Material Insulation class F. Protection IP 54.
Pump casing Chrome-nickel steel 1.4301 EN 10088 (AISI 304) Motor suitable for operation with frequency converter from 1,1 kW.
Stage casing Chrome-nickel steel 1.4301 EN 10088 (AISI 304) Classification scheme IE3 for three-phase motors from 0,75 kW.
Wear ring PTFE Constructed in accordance with: EN 60034-1; EN 60034-30-1.
Impeller Chrome-nickel steel 1.4301 EN 10088 (AISI 304) EN 60335-1, EN 60335-2-41.
Casing cover Chrome-nickel steel 1.4301 EN 10088 (AISI 304)
Spacer sleeve Chrome-nickel steel 1.4301 EN 10088 (AISI 304) Special features on request
- Other voltages. - Frequency 60 Hz (as per 60 Hz data sheet).
Pump shaft Chrome-nickel steel 1.4305 EN 10088 (AISI 303) - Protection IP 55.
Plug Chrome-nickel steel 1.4305 EN 10088 (AISI 303) - Special mechanical seal
Mechanical seal with seat Ceramic alumina, carbon, EPDM - Pump casing seal rings in FPM.
according to ISO 3069 (Other materials on request) - Higher or lower liquid or ambient temperatures.
- Motor suitable for operation with frequency converter up to 0,75 kW.
60 200
180
50
160
H ft
m 140
40
120
MXH 16
30 100
MXH 2 MXH 4 MXH 8
80
20
60
40
10
20
0 0
0 m 3/h 2 4 6 8 10 12 14 16 18 20 22 24 26
0 Q l/min 50 100 150 200 250 300 350 400
72.978/05
115
MXH EI Horizontal Multi-Stage Close Coupled Pumps
in stainless steel
The MXH EI pumps are available with power from 0,55 kW up to 4 kW, the pumps are equipped with I-MAT installed on
board which allows to realize a variable-speed system extremely compact and efficient, ideal in applications of water
supply and in the distribution of hot and cold water.
The pump is equipped with transducers suitable for operation and is already programmed at the factory.
Advantages
- Energy saving
- Compact design
- Easy to use
- Programmable to suit the system requirements
- Reliability
Costruction
The system comprises of:
- Pump
- Induction motor
- I-MAT Frequency converter
- Motor adapter for the motor mounting of the frequency converter
- Connection cable between frequency converter and induction motor
- Transducers
Main features
Rated motor power output from 0,55 kW to 4 kW
Control range from 1750 to 2900 rpm (2-pole)
Protection against dry running
Protection against operations with closed valve ports
Protection against system leakages
Protection against overcurrent in the motor
Protection agains overvoltage and undervoltage of the power supply
Protection against current unbalances between phases
Operating modes
H
Constant pressure mode
with pressure transducer +
-
In this mode, the system maintains the preset pressure when the flow required by
the installation changes.
Q
H
Proportional pressure mode
with pressure transducer +
-
In this mode the system changes the working pressure according to the required
flow rate.
H
Constant flow mode
with flow meter
-
+
In this mode the system maintains a constant flow rate value in a point of the instal-
lation according to the required pressure.
Q
H
Fixed speed mode
with setting of the speed preferential rotation. max
+
-
In this mode, by changing the working frequency, you may choose any operational
curve included within the working range. min
In this mode the system keeps the temperature constant inside a system by chan-
ging the speed of the pump.
116
MXH 2,4,8,16 Horizontal Multi-Stage Close Coupled Pumps
in stainless steel
117
MXH 2,4,8,16 Horizontal Multi-Stage Close Coupled Pumps
in stainless steel
3
0 m /h 1 2 3 4 5 0 m3/h 2 4 6 8
Q Q
0 l/min 20 40 60 80 0 l/min 50 100
50 60
η η
% %
40 50
30 40
8 8
NPSH 20 NPSH 20
m m
ft ft
4 4
10 10
0 0 0 0
0 Q m3/h 1 2 3 4 72.976/05 5 0 Q m 3/h 2 4 6 72.977/05 8
MXH 803 40 ft
30 100 MXH 1603
30 100
20
MXH 802 MXH 1602
20
50
50
10 10
0 m3/h 4 6 8 10 12 14 0 m3/h 8 12 16 20 24 28
Q Q
0 l/min 50 100 150 200 0 l/min 100 200 300 400
70 70
η η
% %
60 50
50 30
4 5 16
12
NPSH NPSH
m 8 m 12
2 ft 3 ft
4 8
4
0 0 1
72.397/1 72.397/2
0 Q m3/h 4 6 8 10 12 14 0 Q m3/h 8 12 16 20 24 28
118
MXH 2,4,8,16 Horizontal Multi-Stage Close Coupled Pumps
in stainless steel
fM
DN1 DN2 mm kg
a 160 TYPE ISO 228 fM a H w1 MXH MXHM
(1) DN 2
DN 1
MXH 202E - MXHM 202E G 1 1/4 G1 331 94 176 98,5 6,8 6,9
MXH 203E - MXHM 203E G 1 1/4 G1 331 94 176 98,5 7,6 7,7
57
H
MXH 205/B - MXHM 205/A G 1 1/4 G1 405 142 193 112 12,3 12,5
127
MXH 402E - MXHM 402E G 1 1/4 G1 331 94 176 98,5 7,6 7,7
MXH 403/A - MXHM 403/A G 1 1/4 G1 357 94 193 112 9,3 10,3
4.93.209
MXH 404/B - MXHM 404/A G 1 1/4 G1 381 118 193 112 11,6 11,8
28 9 30
(2) MXH 802/B - MXHM 802/A G 1 1/2 G1 381 118 193 112 11,4 11,6
10
88 8 112
w1 146
DN1 DN2 mm kg
fM 131 (MXHM 805) TYPE ISO 228
fM a w H h1 h2 m1 m3 b w1 MXH MXHM
a
160 MXH 206/C - MXHM 206 G 1 1/4 G1 500 166 88 210 127 57 31 10 30,5 167 18,5 18,6
(1) DN 2
DN 1
MXH 405/C - MXHM 405 G 1 1/4 G1 476 142 88 210 127 57 31 10 30,5 167 18 18
MXH 406/A - MXHM 406 G 1 1/4 G1 500 166 88 210 127 57 31 10 30,5 167 19,5 20,5
h2
MXH 803/A - MXHM 803 G 1 1/2 G1 452 118 88 210 127 57 31 10 30,5 167 15,8 16,9
MXH 804/A - MXHM 804 G 1 1/2 G1 482 148 88 210 127 57 31 10 30,5 167 18,2 19,2
H
h1
MXH 805/B - MXHM 805 G 1 1/2 G1 552 178 88 210 127 57 31 10 30,5 207 21,4 22,4
MXH 1602/A G2 G 1 1/2 476 128 101 210 117 70 31 10 30,5 167 18,2 -
3.93.020/1
MXH 1603/B G2 G 1 1/2 516 128 101 210 117 70 31 10 30,5 207 20,8 -
m1 10 b
10,5
MXH 1604/A G2 G 1 1/2 612 166 113 235 132 70 44 12 38 232 33,8 -
(2) w m3 112
w1 146 MXH 1605/B G2 G 1 1/2 650 203 113 235 132 70 44 12 38 232 35,5 -
MXH 1606/B G2 G 1 1/2 687 241 113 235 132 70 44 12 38 232 36,4 -
fM 190
105
a
DN 2
DN1 DN2 mm
(1)
TYPE ISO 228 fM a H w1 kg
DN 1
108
28 9 30
(2)
10
88 8 112
w1 146
160
fM AG
AS
DN1 DN2 mm
TYPE
ISO 228 kg
a fM AG AS a w H h1 h2 m1 m3 b w1
DN 2 MXH EI 206/C G 1 1/4 G1 532 190 105 166 88 368 127 108 31 10 30,5 167 24,9
(1) MXH EI 405/C G 1 1/4 G1 508 190 105 142 88 368 127 108 31 10 30,5 167 24,4
DN 1
MXH EI 406/A G 1 1/4 G1 532 190 105 166 88 368 127 108 31 10 30,5 167 25,9
h2
MXH EI 803/A G 1 1/2 G1 484 190 105 118 88 368 127 108 31 10 30,5 167 22,2
H
MXH EI 804/A G 1 1/2 G1 514 190 105 148 88 368 127 108 31 10 30,5 167 24,6
MXH EI 805/B G 1 1/2 G1 552 190 105 178 88 368 127 108 31 10 30,5 207 27,8
h1
MXH EI 1602/A G2 G 1 1/2 508 190 105 128 101 368 117 122 31 10 30,5 167 24,6
MXH EI 1603/B G2 G 1 1/2 516 190 105 128 101 368 117 122 31 10 30,5 207 27,2
3.93.020/2
m1 10 b MXH EI 1604/A G2 G 1 1/2 627 210 118 166 113 391 132 122 44 12 38 232 41,3
10,5
(2) w m3 112 MXH EI 1605/B G2 G 1 1/2 665 210 118 203 113 391 132 122 44 12 38 232 43,0
w1 146 MXH EI 1606/B G2 G 1 1/2 702 210 118 241 113 391 132 122 44 12 38 232 43,9
160
Features
3.93.001
Extra safety
against running dry, with the suction port above pump axis.
Reliable
All hydraulic parts in contact with the pumped liquid are of stainless steel.
For liquids from -15 °C to 110 °C.
Robust
Single-piece, thick barrel casing.
Compact
Single-piece lantern bracket and base.
Without protruding flange.
Greater protection
against leakage, with the pump casing cover separated from the motor shield.
Possibility of inspecting the seal through the side apertures between the two walls.
Greater protection against water entering the motor from outside provided by an
extension of the pump casing around the lantern bracket.
120
MXHL AISI 316L Horizontal Multi-Stage
Close Coupled Pumps
Construction
Horizontal multi-stage close coupled pumps in chrome-
nickel-molybdenum stainless steel AISI 316L.
Compact and robust construction, without protruding flange
and with single-piece lantern bracket and base.
Single-piece barrel casing, with front suction port above
pumps axis and radial delivery at top.
Filling and draining plugs on the middle of the pump, accessi-
ble from any side (like the terminal box).
Applications
For water supply.
For clean liquids, without abrasives, which are non-aggressive
for stainless steel (with suitable seal materials, on request).
Universal pump, for domestic use, for civil and industrial
applications, for garden use and irrigation.
Operating conditions
Liquid temperature from - 15 °C to + 110 °C.
Ambient temperature up to 40 °C.
Maximum permissible pressure in the pump casing: 8 bar.
Continuous duty.
Motor
2-pole induction motor, 50 Hz (n ≈ 2800 rpm).
MXHL: three-phase 230/400 V ± 10%.
MXHLM: single-phase 230 V ± 10%, with thermal protector.
Materials Capacitor inside the terminal box.
Insulation class F. Protection IP 54.
Component Material
Motor suitable for operation with frequency converter from 1,1 kW.
Pump casing Cr-Ni-Mo steel 1.4404 EN 10088 (AISI 316L) Classification scheme IE3 for three-phase motors from 0,75 kW.
Stage casing Cr-Ni-Mo steel 1.4404 EN 10088 (AISI 316L) Constructed in accordance with: EN 60034-1; EN 60034-30-1.
Wear ring PTFE EN 60335-1, EN 60335-2-41.
Impeller Cr-Ni-Mo steel 1.4404 EN 10088 (AISI 316L)
Casing cover Cr-Ni-Mo steel 1.4404 EN 10088 (AISI 316L) Special features on request
Spacer sleeve Cr-Ni-Mo steel 1.4404 EN 10088 (AISI 316L) - Other voltages. - Frequency 60 Hz (as per 60 Hz data sheet).
Pump shaft Cr-Ni-Mo steel 1.4404 EN 10088 (AISI 316L) - Protection IP 55.
Plug Cr-Ni-Mo steel 1.4404 EN 10088 (AISI 316L) - Special mechanical seal
- Pump casing seal rings in FPM.
Mechanical seal with seat Ceramic alumina, carbon, EPDM
- Higher or lower liquid or ambient temperatures.
according to ISO 3069 (Other materials on request) - Motor suitable for operation with frequency converter up to 0,75 kW.
0 U.S. g.p.m. 10 20 30 40 50 60
70
220
60 200
180
50
160
H ft
m 140
40
120
30 100
MXHL 2 MXHL 4 MXHL 8
80
20
60
40
10
20
0 0
0 m 3/h 2 4 6 8 10 12 14
0 Q l/min 50 100 150 200
72.978/05
121
MXHL AISI 316L Horizontal Multi-Stage
Close Coupled Pumps
P1 Max. power input. Test results with clean cold water, without gas content. + 0,5 m security margin on NPSH-value is necessary.
P2 Rated motor power output. Tolerances according to UNI EN ISO 9906:2012
MXHL 202E - MXHLM 202E G 1 1/4 G 1 331 94 176 98,5 6,8 6,9
MXHL 203E - MXHLM 203E G 1 1/4 G 1 331 94 176 98,5 7,6 7,7
H
MXHL 205/B - MXHLM 205/A G 1 1/4 G 1 405 142 193 112 12,3 12,5
4.93.209
MXHL 402E - MXHLM 402E G 1 1/4 G 1 331 94 176 98,5 7,6 7,7
28 9 30 MXHL 403/A - MXHLM 403/A G 1 1/4 G 1 357 94 193 112 9,3 10,3
(2)
10
88 8 112 MXHL 404/B - MXHLM 404/A G 1 1/4 G 1 381 118 193 112 11,6 11,8
w1 146 MXHL 802/B - MXHLM 802/A G 1 1/2 G 1 381 118 193 112 11,4 11,6
DN1 DN2 mm kg
TYPE
215 (MXHLM 805)
57
ISO 228
fM a w1 MXHL MXHLM
MXHL 206/C - MXHLM 206 G 1 1/4 G1 500 166 167 18,5 18,6
210
MXHL 406/A - MXHLM 406 G 1 1/4 G1 500 166 167 19,5 20,5
3.93.020/1
MXHL 803/A - MXHLM 803 G 1 1/2 G1 452 118 167 15,8 16,9
31 10 30,5 MXHL 804/A - MXHLM 804 G 1 1/2 G1 482 148 167 18,2 19,2
10,5
(2) 88 10 112 MXHL 805/B - MXHLM 805 G 1 1/2 G1 552 178 207 21,4 22,4
w1 146
122
MXHL AISI 316L Horizontal Multi-Stage
Close Coupled Pumps
3
0 m /h 1 2 3 4 5 0 m3/h 2 4 6 8
Q Q
0 l/min 20 40 60 80 0 l/min 50 100
50 60
η η
% %
40 50
30 40
8 8
NPSH 20 NPSH 20
m m
ft ft
4 4
10 10
0 0 0 0
0 Q m3/h 1 2 3 4 72.976/05 5 0 Q m 3/h 2 4 6 72.977/05 8
0 U.S. g.p.m. 20 30 40 50 60
60 200
H
m
MXHL 805
50
150
MXHL 804
40
ft
MXHL 803
30 100
MXHL 802
20
50
10
0 m3/h 4 6 8 10 12 14
Q
0 l/min 50 100 150 200
70
η
%
60
50
4
12
NPSH
m 8
2 ft
4
0 0
72.397/1
0 Q m3/h 4 6 8 10 12 14
123
MXHL AISI 316L Horizontal Multi-Stage
Close Coupled Pumps
Features
3.93.001
Extra safety
against running dry, with the suction port above pump axis.
Reliable
All hydraulic parts in contact with the pumped liquid are of stainless steel.
For liquids from -15 °C to 110 °C.
Robust
Single-piece, thick barrel casing.
Compact
Single-piece lantern bracket and base.
Without protruding flange.
Greater protection
against leakage, with the pump casing cover separated from the motor shield.
Possibility of inspecting the seal through the side apertures between the two walls.
Greater protection against water entering the motor from outside provided by an
extension of the pump casing around the lantern bracket.
124
MXH 20,32,48 Horizontal Multi-Stage
Close Coupled Pumps
Construction
Horizontal multi-stage close coupled pumps in chrome-nickel
stainless steel.
Compact and robust construction,with compact lantern
bracket and motor with feet.
Single-piece barrel casing, with front suction port above
pumps axis and radial delivery at top.
Filling and draining plugs on the middle of the pump,
accessible from any side (like the terminal box).
Version with frequency converter (on request)
Applications
For water supply.
For clean liquids, without abrasives, which are non-aggressive
for stainless steel (with suitable seal materials, on request).
Universal pump, for civil and industrial applications, for garden
use and irrigation.
Operating conditions
Liquid temperature from - 15 °C to + 110 °C.
Ambient temperature up to 40 °C.
Maximum permissible pressure in the pump casing: 10 bar.
Motor
2-pole induction motor, 50 Hz (n ≈ 2900 rpm).
MXH: three-phase 230/400 V ± 10% up to 3 kW;
400/690 V ± 10% from 4 to 7,5 kW.
Insulation class F. Protection IP 54.
Materials Motor suitable for operation with frequency converter.
Component Material Classification scheme IE3 for three-phase motors from 0,75 kW.
Constructed in accordance with: EN 60034-1;
Pump casing Chrome-nickel steel 1.4301 EN 10088 (AISI 304) EN 60034-30-1.
Stage casing Chrome-nickel steel 1.4301 EN 10088 (AISI 304)
Wear ring PTFE
Impeller Chrome-nickel steel 1.4301 EN 10088 (AISI 304)
Special features on request
- Pump with Victaulic ports (MXH-V).
Casing cover Chrome-nickel steel 1.4301 EN 10088 (AISI 304)
- Pump with flanged ports (MXH-F).
Spacer sleeve Chrome-nickel steel 1.4301 EN 10088 (AISI 304) - Other voltages.
Pump shaft Chrome-nickel steel 1.4401 EN 10088 (AISI 316) - Frequency 60 Hz (as per 60 Hz data sheet).
Plug Chrome-nickel steel 1.4305 EN 10088 (AISI 303) - Protection IP 55.
- Special mechanical seal
Mechanical seal with seat Ceramic alumina, carbon, EPDM
- Seal rings in FPM.
according to ISO 3069-KU (Other materials on request)
- Higher or lower lambient temperatures.
80
70
200
60
H
m
ft
40
MXH 20 MXH 32
30 100
MXH 48
20
10
0 72.978/05
0
0 m 3/h 10 20 30 40 50 60 70
0 Q l/min 200 400 600 800 1000
125
MXH EI Horizontal Multi-Stage
Close Coupled Pumps
The MXH EI pumps are available with power from 1,1 kW up to 7,5 kW, the pumps are equipped with I-MAT
installed on board which allows to realize a variable-speed system extremely compact and efficient, ideal in
applications of water supply and in the distribution of hot and cold water.
The pump is equipped with transducers suitable for operation and is already programmed at the factory.
Advantages
- Energy saving
- Compact design
- Easy to use
- Programmable to suit the system requirements
- Reliability
Costruction
The system comprises of:
- Pump
- Induction motor
- I-MAT Frequency converter
- Motor adapter for the motor mounting of the frequency converter
- Connection cable between frequency converter and induction motor
- Transducers
Main features
Rated motor power output from 1,1 kW to 7,5 kW
Control range from 1750 to 2900 rpm (2-pole)
Protection against dry running
Protection against operations with closed valve ports
Protection against system leakages
Protection against overcurrent in the motor
Protection agains overvoltage and undervoltage of the power supply
Protection against current unbalances between phases
Operating modes
H
Constant pressure mode
with pressure transducer +
-
In this mode, the system maintains the preset pressure when the flow required by
the installation changes.
Q
H
Proportional pressure mode
with pressure transducer +
-
In this mode the system changes the working pressure according to the required
flow rate.
H
Constant flow mode
with flow meter
-
+
In this mode the system maintains a constant flow rate value in a point of the instal-
lation according to the required pressure.
Q
H
Fixed speed mode
with setting of the speed preferential rotation. max
+
-
In this mode, by changing the working frequency, you may choose any operational
curve included within the working range. min
In this mode the system keeps the temperature constant inside a system by chan-
ging the speed of the pump.
126
MXH 20,32,48 Horizontal Multi-Stage
Close Coupled Pumps
H
DN1
150
g2
g2*
w s1 b1
m5 w1 n5
m4 n4
DN1 DN2 mm
TYPE
ISO 228 kg
fM a H m4 m5 n4 n5 w1 b1 s1 w g2
MXH 2001/A G2 G 1 1/2 467 127 280 205 175 170 130 15 54 10 95 6* 26
MXH 2002/A G2 G 1 1/2 507 127 280 205 175 170 130 15 54 10 95 6* 30
MXH 2003 G2 G 1 1/2 540 146 290 205 175 180 140 15 54 10 112 6* 38
MXH 2004/A G2 G 1 1/2 574 180,5 290 205 175 180 140 15 54 10 112 6* 39 Flanges*
Flange* EN 1092-2
MXH 2005 G2 G 1 1/2 630,5 215 310 280 250 258 190 15 68 12 84 38 50,5
Holes
Fori
MXH 3201/B G 2 1/2 G2 503,5 123 280 205 175 170 130 15 54 10 95 6* 29,4
DN DE DK DG
MXH 3202/B G 2 1/2 G2 517,5 123 290 205 175 180 140 15 54 10 112 6* 38,5 N. Ø
MXH 3203/A G 2 1/2 G2 584,5 169 310 280 250 258 190 15 68 12 84 38 50 DN 40 150 110 81 4 19
MXH 3204/A G 2 1/2 G2 630,5 215 310 280 250 258 190 15 68 12 84 38 57,5 DG 50 165 125 99 4 19
MXH 4801/A G3 G 2 1/2 547,5 138,5 290 205 175 180 140 15 54 10 128,5 6* 38 DK 65 185 145 118 4 19
MXH 4802/A G3 G 2 1/2 568,5 138,5 310 280 250 258 190 15 68 12 100 38 49,5 DE 80 200 160 132 8 19
MXH 4803/A G3 G 2 1/2 630,5 200 310 280 250 258 190 15 68 12 100 38 58
* ASME 150 lb (ex ANSI 150 lb)
mm
Victaulic ports Flanged ports TYPE DN1 DN2
MXH-V MXH-F mm mm fMF aF
fMV fMF MXH-F 2001/A 50 40 502 161,5
aV aF MXH-F 2002/A 50 40 542 161,5
DN2 DN2 MXH-F 2003 50 40 575 180,5
mm
TYPE DN1 DN2 MXH-F 2004/A 50 40 624 215
mm mm fMV aV MXH-F 2005 50 40 665 249,5
MXH-V 3201/B 76,1 (DN65) 60,3 (DN50) 541 160 MXH-F 3201/B 65 50 531 151
175
177
MXH-V 3202/B 76,1 (DN65) 60,3 (DN50) 555 160 MXH-F 3202/B 65 50 545 151
MXH-V 3203/A 76,1 (DN65) 60,3 (DN50) 622 206 MXH-F 3203/A 65 50 612 197
MXH-V 3204/A 76,1 (DN65) 60,3 (DN50) 668 252 MXH-F 3204/A 65 50 658 243
MXH-V 4801/A 88,9 (DN80) 76,1 (DN65) 585 175 MXH-F 4801/A 80 65 565 156
DN1
DN1
150
150
MXH-V 4802/A 88,9 (DN80) 76,1 (DN65) 606 175 MXH-F 4802/A 80 65 586 156
MXH-V 4803/A 88,9 (DN80) 76,1 (DN65) 668 237 MXH-F 4803/A 80 65 648 218
127
MXH 20,32,48 Horizontal Multi-Stage
Close Coupled Pumps
Threaded ports
AG
MXH EI
fM AS
250
a
DN2
h2
H
DN1
150
g2
g2*
w s1 b1
m5 w1 n5
m4 n4
DN1 DN2 mm
TYPE ISO 228
fM AG AS a H h2 m4 m5 n4 n5 w1 b1 s1 w g2 kg
MXH EI 2001/A G2 G 1 1/2 499 190 105 127 436 192 205 175 170 130 15 54 10 95 6* 32,4
MXH EI 2002/A G2 G 1 1/2 532 210 118 127 436 192 205 175 170 130 15 54 10 95 6* 36,4
MXH EI 2003 G2 G 1 1/2 572 210 118 146 444 192 205 175 180 140 15 54 10 112 6* 45,5
MXH EI 2004/A G2 G 1 1/2 606 210 118 180,5 444 192 205 175 180 140 15 54 10 112 6* 46,5
MXH EI 2005 G2 G 1 1/2 630,5 210 118 215 472 192 280 250 258 190 15 68 12 84 38 65,3
MXH EI 3201/B G 2 1/2 G2 528,5 210 118 123 436 197 205 175 170 130 15 54 10 95 6* 35,8
MXH EI 3202/B G 2 1/2 G2 594,5 210 118 123 444 197 205 175 180 140 15 54 10 112 6* 46,0
MXH EI 3203/A G 2 1/2 G2 594,5 210 118 169 472 197 280 250 258 190 15 68 12 84 38 64,8
MXH EI 3204/A G 2 1/2 G2 665,5 281 153 215 518 197 280 250 258 190 15 68 12 84 38 72,3
MXH EI 4801/A G3 G 2 1/2 579,5 210 118 138,5 444 202 205 175 180 140 15 54 10 128,5 6* 45,5
MXH EI 4802/A G3 G 2 1/2 568,5 210 118 138,5 472 202 280 250 258 190 15 68 12 100 38 64,3
MXH EI 4803/A G3 G 2 1/2 665,5 281 153 200 518 202 280 250 258 190 15 68 12 100 38 72,8
128
MXH 20,32,48 Horizontal Multi-Stage
Close Coupled Pumps
10 10
0 0 0 0
0 m 3/h 5 10 15 20 25 0 m 3/h 10 20 30 40 50
Q Q l/min
0 l/min 100 200 300 400 0 200 300 400 500 600 700 800
70 1,6 70 2,5
η η
η 1,2 η 2
50 0,8 50 1,5
Pst Pst
% Pst % Pst
kW kW
30 0 30 0,5
8 8
NPSH 20 NPSH 20
ft ft
4 4
10 10
m m
0 0 0 0
72.974 72.974
0 Q m 3/h 5 10 15 20 25 0 Q m 3/h 10 20 30 40 50
60 200
MXH 4803
H
m
ft
40
MXH 4802
30 100
20 MXH 4801
10
Designation
0 0
0
Q
m3/h 10 20 30 40 50 60 70 MXH-F EI 3204 *
0 l/min 200 400 600 800 1000
70 3 Series
η
60 2,5 No code = threaded ports
η% Pst Victaulic ports V
50 2
Pst kW Flanged ports F
40 1,5
With frequency converter I-MAT
30 1 Rated capacity in m3/h
6 ft Number of stages
NPSH
4 ft Construction variants
m 10 special seal code (no code = standard seal)
2
0 0
72.1035
0 Q m3/h 10 20 30 40 50 60 70
129
MXH 20,32,48 Horizontal Multi-Stage
Close Coupled Pumps
Features
Flexibility
Three versions of ports: threaded, flanged and Victaulic.
Extra safety
With front axis suction port for optimum suction conditions.
Reliable
All hydraulic parts in contact with the pumped liquid are made in stainless steel.
For liquids from -15 °C to 110 °C.
Robust
Single-piece, thick barrel casing, open on one side only, with reinforced threaded
ports.
Compact
The bracket between pump and motor is extremely compact.
Greater protection
Against leakage, with the pump casing cover separated from the motor shield.
Possibility of inspecting the seal through the side apertures between the two walls.
130
03/2021
Construction
Horizontal multi-stage close coupled pump.
Single-piece barrel casing in chrome-nickel stainless steel, with
front suction port above pumps axis and radial delivery at top.
Stages in Noryl.
Applications
For water supply.
For domestic use, for garden use and irrigation.
Operating conditions
Liquid temperature: 0 °C to +50 °C.
Ambient temperature up to +40 °C.
Maximum permissible pressure in the pump casing: 8 bar.
Continuous duty.
Motor
2-pole induction motor, 50 Hz (n ≈ 2800 rpm).
MXP: three-phase 230/400 V ± 10%.
MXPM: single-phase 230 V ± 10%, with thermal protector.
Capacitor inside the terminal box.
Insulation class F.
Protection IP 54.
Materials Motor suitable for operation with frequency converter from 1,1 kW.
Component Material Classification scheme IE3 for three-phase motors from 0,75 kW.
Pump casing Cr-Ni steel 1.4301 EN 10088 (AISI 304) Constructed in accordance with: EN 60034-1; EN 60034-30-1.
Casing cover Cr-Ni steel 1.4301 EN 10088 (AISI 304) EN 60335-1, EN 60335-2-41.
60
MXP 200 60 406
MXP 200
206
205 405
50 50
H 150 H 150
m m
204 404
40 40
ft ft
20 202 20 402
50 50
10 10
0 0 0 0
0 m3/h 1 2 3 4 5 0 m3/h 2 4 6 8
0
Q l/min 20 40 60 80 0 Q l/min 50 100
45 4 55 4
η η NPSH
40 NPSH 50 NPSH
m m
η NPSH η
2 2
% %
30 40
25 0 35 0
0 Q m3/h 1 2 3 4 5 72.1136 0 Q m3/h 2 4 6 72.1137 8
131
MXP Horizontal Multi-Stage Close Coupled Pumps
H
ISO 228
DN1
h1
4.93.281
m2 m3 s b
g1
m1 n2
w w1 n1
Dimensions
Dimensioni Pesoweight
Net netto
TIPO
TYPE DN1 DN2 mm kg
ISO 228 fM a w h1 h2 H L m1 m2 m3 n1 n2 b s g1 w1 MXP MXPM
MXP 202 - MXPM 202 G1 G 1 362 115 95 116 61 176 161 33 25 8 146 112 30 9 10 102 5,9 6
MXP 203 - MXPM 203 G1 G 1 362 115 95 116 61 176 161 33 25 8 146 112 30 9 10 102 6,6 6,7
MXP 204/A - MXPM 204/A G1 G 1 391 115 95 116 61 192 161 33 25 8 146 112 30 9 10 112 8,7 9,6
MXP 205/A - MXPM 205 G1 G 1 391 115 95 116 61 192 161 33 25 8 146 112 30 9 10 112 10,3 10,5
MXP 206 - MXPM 206 G 1 1/4 G 1 462 140 113 152 68 225 213,5 37,5 28 9,5 185 155 33 9,5 11 147 12,5 12,5
MXP 402 - MXPM 402 G1 G 1 362 115 95 116 61 176 161 33 25 8 146 112 30 9 10 102 6,5 6,6
MXP 403/A - MXPM 403/A G1 G 1 391 115 95 116 61 192 161 33 25 8 146 112 30 9 10 112 8,6 9,5
MXP 404/B - MXPM 404/A G1 G 1 391 115 95 116 61 192 161 33 25 8 146 112 30 9 10 112 10,3 10,5
MXP 405 - MXPM 405 G1 G 1 421 115 95 116 61 192 161 33 25 8 146 112 30 9 10 142 13,2 13,5
MXP 406 - MXPM 406 G 1 1/4 G 1 488,5 140 113 152 68 240 213,5 37,5 28 9,5 185 155 33 9,5 11 157,5 17,5 17,5
Features
Extra safety
against running dry, with the suction port
above pump axis.
Robust
Single-piece barrel casing.
Compact
Single-piece lantern bracket and base.
Low noise
with the water-filled shroud around the stages.
3.93.123
132
03/2021
Construction
Horizontal multi-stage close coupled pump.
Single-piece barrel casing in cast iron, with front suction
port above pumps axis and radial delivery at top.
Stages in Noryl.
Applications
For water supply.
For domestic use, for garden use and irrigation.
Operating conditions
Liquid temperature: 0 °C to +50 °C.
Ambient temperature up to +40 °C.
Maximum permissible pressure in the pump casing: 8 bar.
Continuous duty.
Motor
2-pole induction motor, 50 Hz (n ≈ 2800 rpm).
MGP: three-phase 230/400 V ± 10%.
MGPM: single-phase 230 V ± 10%, with thermal protector.
Capacitor inside the terminal box.
Insulation class F.
Materials Protection IP 54.
Component Material Motor suitable for operation with frequency converter from 1,1 kW.
Classification scheme IE3 for three-phase motors from 0,75 kW.
Pump casing Cast iron GJL 200 EN 1561 Constructed in accordance with: EN 60034-1; EN 60034-30-1.
EN 60335-1, EN 60335-2-41.
Casing cover Cr-Ni steel 1.4301 EN 10088 (AISI 304)
Pump Shaft Chrome steel 1.4104 EN 10088 (AISI 430)
Stage casing PPO-GF20 (Noryl)
Special features on request
Impeller PPO-GF20 (Noryl) - Other voltages.
- Frequency 60 Hz (as per 60 Hz data sheet).
Mechanical seal Carbon - Ceramic - NBR - Motor suitable for operation with frequency converter up to 0,75 kW.
10 10
0 0 0 0
3
0 m /h 1 2 3 4 5 0 m3/h 2 4 6 8
Q Q l/min
0 l/min 20 40 60 80 0 50 100
45 4 55 4
η η NPSH
40 NPSH 50 NPSH
m m
η NPSH η
2 2
% %
30 40
25 0 35 0
0 Q m3/h 1 2 3 4 5 72.976 0 Q m3/h 2 4 6 72.977 8
133
MGP Horizontal Multi-Stage Close Coupled Pumps
fM
115
G1 ISO 228 161 Net weight
mm kg
TYPE
fM H w1 MGP MGPM
51
4.93.367 MGP 205/A - MGPM 205 391 192 112 13,3 13,5
MGP 402 - MGPM 402 362 176 102 9,5 9,6
33 9 30
10
Features
Extra safety
Più sicurezza
against
contro running dry, witha the
il funzionamento suction
secco, con laport above
bocca
pump axis.sopra l'asse della pompa.
aspirante
Robust
Robusta
Single-piece
Corpo pompabarrel casing.
in un solo pezzo aperto su un solo
lato.
Compact
Single-piece
Compattalantern bracket and base.
Raccordo
Low noisepompa-motore e base in un solo pezzo.
with the water-filled shroud around the stages.
Bassa rumorosità
con il mantello d'acqua attorno agli stadi.
134
03/2021
Construction
PATENTED 5” Vertical multi-stage close coupled submersible or surface
pumps.
External jacket in stainless steel AISI 304 and stages Noryl.
MPSUM with built-in capacitor, accessible through the delivery
casing.
Suction connection on the lower casing and delivery connec-
tion on the top casing.
Motor cooled by the pumped water passing between the
motor jacket and the external jacket.
Double mechanical shaft seal with interposed oil chamber.
Applications
For clean water without abrasives or additives aggressive
for the materials of the pump.
For domestic, civil and industrial applications.
For installation in confined space with minimum ventilation.
For installation in locations subject to risk of temporary flooding,
the pump can be fully immersed.
For installation in areas exposed to water jetting.
When low-noise operation is required.
Operating conditions
Water temperature up to 35 °C.
Maximum permissible pressure in the pump casing: 8 bar.
Continuous duty.
Motor
2-pole induction motor, 50 Hz (n ≈ 2900 1/min).
MPSU : three-phase 230 V ± 10%;
Materials three-phase 400 V ± 10%.
Cable: H07RN8-F, length 5 m, without plug.
Component Material
MPSUM :single-phase 230 V ± 10%, with thermal protector.
Delivery casing
External jacket Incorporated capacitor.
Chrome-nickel steel 1.4301 EN 10088 (AISI 304) Float switch MPSUM.. CG (on demand)
Base
Motor jacket Cable: H07RN8-F, length 5 m, with plug CEI-UNEL 47166.
Stage casing Insulation class F.
PPO-GF20 (Noryl)
Impeller Protection IP X8 (for continuous immersion).
Shaft Chrome-nickel steel 1.4301 EN 10088 (AISI 304) Triple impregnation humidity-proof dry winding.
Capacitor cover Constructed in accordance with EN 60034-1;
Oil chamber cover EN 60335-1, EN 60335-2-41.
PPS Polymer (Grivory)
Preload ring stages
Support ring preload Special features on request
Upper mechanical seal Steatite, carbon, NBR - Other voltages. - Frequency 60 Hz (as per 60 Hz data sheet).
Lower mechanical seal Carbon, silicon carbide, NBR - Cable length 15 m.
Seal lubrication oil Oil for food machinery and pharmaceutic use - Motor suitable operation with frequency converter.
90 300
ft
80
250
70
H 200
m
50
150
40
MPSU
MPS 33
30 100
MPSU
MPS 55
20
50
10
0 0
0 m3/h 2 4 6 8 10
Q
0 l/min 50 100 150
72.986/1
135
MPSU Vertical multi-stage close coupled pumps
Ø7
G1 1/4
ISO 228
(fM)
fM kg Cavo H07RN8-F
PUMP
230V 230V 400V
mm MPSU MPSUM 1~ 3~ 3~
MPSU 304 - MPSUM 304 553 11,4 12,4 3G1 mm2 4G1 mm2 4G1 mm2
ISO 228
G1 1/4
MPSU 305 - MPSUM 305 602 12,7 13,7 3G1 mm2 4G1 mm2 4G1 mm2
MPSU 306 - MPSUM 306 626 13,3 14,8 3G1 mm2 4G1 mm2 4G1 mm2
MPSU 307 - MPSUM 307 650 13,5 15 3G1 mm2 4G1 mm2 4G1 mm2
578 13,1 14,1 3G1 mm2 4G1 mm2 4G1 mm2
2
4.93.687
MPSU 505 - MPSUM 505 602 14 15 3G1 mm2 4G1 mm2 4G1 mm2
100 MPSU 506 - MPSUM 506 671 15,5 17 3G1,5 mm2 4G1 mm2 4G1 mm2
MPSU 507 - MPSUM 507 720 17 18,5 3G2,5 mm2 4G1 mm2 4G1 mm2
205
180
136
MPSU Vertical multi-stage close coupled pumps
300 300
90 MPSU 3 90 MPSU 5
80 80
250 250
H H
70 307 70
m m 507
60 306 200 60 200
506
ft ft
50 305 50
150 505 150
304
40 40
504
30 100 30 100
20 20
50 50
10 10
0 0 0 0
0 m 3/h 1 2 3 4 5 0 m3/h 2 4 6 8
0 Q l/min 20 40 60 80 0 Q l/min 50 100
40 50
η η
% %
30 40
5 16 10 32
NPSH 12 NPSH 24
m 3 ft m 6 ft
8 16
2 4
1 4 8
2
0 0 0 0
0 Q m3 /h 1 2 3 4 72.980.2
5 0 Q m3 /h 2 4 6 72.981.2
8
Installation examples
B
100 mm 150 mm
min min
4.93.177
150 mm
3.93.037/4
min
137
MPSU Vertical multi-stage close coupled pumps
Features
PATENTED
Innovative
Designed to withstand water hammering and
the ON-OFF operation of any valve located in
the discharge line.
The impacts generated by water hammering
or by the closing of the valve are fully
supported by the capacitor cover,which
relieves the stresses on a specific support
made on the stainless steel jacket, without
affecting the plastic hydraulic part.
Low-Noise operation
The design of hydraulic parts, the
Flexible water-filled shroud around the
Allows the inspection of the capacitor motor and the submerged opera-
without disassembling the pump, through tion ensures low noise operation.
the delivery casing.
Reliable
The ball bearings and shaft are sized in
order to reduce stresses, guaranteeing
high reliability in any operating condition. Greater Safety
The double shaft sealing with an oil
chamber separates the motor from
the water and provides further pro-
tection against accidental opera-
tion when dry.
138
03/2021
Construction
Vertical multi-stage close coupled pumps with suction and deli-
very connections of the same diameter and arranged along the
same axis (in-line).
All parts that come into contact with the liquid, including wet-end
covers, are in chrome-nickel stainless steel with corrosion-
resistant bearing sleeves lubricated by the pumped liquid.
Version with frequency converter (on request)
Applications
For water supply systems.
For clean non-explosive liquids, without solid, filamentary or
abrasive matter and non-aggressive for stainless steel (with
adaptation of sealing materials on request).
A universal pump for civil and industrial use, for pressure-
boosting systems, high-pressure washing plants, irrigation,
agricultural uses and sport installations.
Operating conditions
Temperature of liquid: from -15 °C to +90 °C.
Operating environment temperature: up to 40 °C.
Maximum permissible pressure in pump casing: 16 bar.
Motor
2-pole induction motor, 50 Hz (n ≈ 2900 rpm).
MXV-B: three-phase 230/400 V ± 10% up to 3 kW;
400/690 V ± 10% from 3,7 to 7,5 kW.
MXV-BM: single-phase 230 V ± 10%, with thermal protector.
Capacitor inside the terminal box.
Insulation class F. Protection IP 54.
Motor suitable for operation with frequency converter from 1,1 kW.
Classification scheme IE3 for three-phase motors from 0,75 kW.
Constructed in accordance with: EN 60034-1, EN 60034-30-1.
EN 60335-1, EN 60335-2-41.
Designation
MXV-B M E I 2 5 - 2 0 5
20
Series
Single-phase motor (up to 2.2 kW)
15 50 With frequency converter I-MAT
1 m3/h 2 3 4 5 10 20 30
Q DN ports in mm
20 l/min 30 40 50 100 150 200 300 400 500
Rated capacity in m3/h
72.1002/1
Number of stages
139
MXV-B EI Vertical Multi-Stage In-Line Pumps
Advantages
- Energy saving
- Compact design
- Easy to use
- Programmable to suit the system requirements
- Reliability
Costruction
The system comprises of:
- Pump
- Induction motor
- I-MAT Frequency converter
- Motor adapter for the motor mounting of the frequency converter
- Connection cable between frequency converter and induction motor
- Transducers
Main features
Rated motor power output from 0,75 kW to 7,5 kW
Control range from 1750 to 2900 rpm (2-pole)
Protection against dry running
Protection against operations with closed connection ports
Protection against system leakages
Protection against overcurrent in the motor
Protection agains overvoltage and undervoltage of the power supply
Protection against current unbalances between phases
Operating modes
H
Constant pressure mode
with pressure transducer +
-
In this mode, the system maintains the preset pressure when the flow required by
the installation changes.
Q
H
Proportional pressure mode
with pressure transducer +
-
In this mode the system changes the working pressure according to the required
flow rate.
H
Constant flow mode
with flow meter
-
+
In this mode the system maintains a constant flow rate value in a point of the instal-
lation according to the required pressure.
Q
H
Fixed speed mode
with setting of the speed preferential rotation. max
+
-
In this mode, by changing the working frequency, you may choose any operational
curve included within the working range. min
In this mode the system keeps the temperature constant inside a system by chan-
ging the speed of the pump.
140
MXV-B 25-2 Vertical Multi-Stage Close Coupled Pumps
MXV-B 25-210
100
300
8
80
7 ft
H
m
6
200
60
5
4
40
3
100
20
0 0
0 m3/h 1 2 3 4 5
0
Q l/min 20 30 40 50 60 70 80
50 0.2
η Pst
Pst Test results with clean cold water, without gas
40 0.1
η content.
% kW A safety margin of + 0.5 m is recommended for
the NPSH value.
30 0 Tolerances in accordance with UNI EN ISO 9906:2012
4
Head and power values valid for liquids with
NPSH 10
density ρ = 1,0 kg/dm3 and kinematic viscosity
2 ft ν = max 20 mm2/sec.
MXV-B 25-203 4 2,3 MXV-BM 25-203 5,8 1,1 0,75 1 34 32 30 28 26 23,5 20,5 17 12,5
MXV-B 25-204 4 2,3 MXV-BM 25-204 5,8 1,1 0,75 1 44 42,5 40 37,5 34,5 31 27 22,5 17
MXV-B 25-205 4 2,3 MXV-BM 25-205 5,8 1,1 0,75 1 56 53 50 47 43 39 34 28 21
MXV-B 25-206/A 4,7 2,7 MXV-BM 25-206 7,4 1,5 1,1 1,5 H 68 63,5 60,5 56 51,5 46,5 40,5 34 25
MXV-B 25-207/A 4,7 2,7 MXV-BM 25-207 7,4 1,6 1,1 1,5 m 79,5 74 70,5 65,5 60 54,5 47,5 39,5 30
MXV-B 25-208/A 7,5 4,3 MXV-BM 25-208 9,2 2 1,5 2 91 85 80,5 75 69 62 54 45,5 34
MXV-B 25-210/A 7,5 4,3 MXV-BM 25-210 9,2 2,3 1,5 2 114 106 101 94 86 78 68 57 42
141
MXV-B 32-4 Vertical Multi-Stage Close Coupled Pumps
MXV-B 32-410
100
300
8
80
ft
H 7
m
60
6
200
4
40
3
100
20
0
0 3
m /h 2 3 4 5 6 7 8 9 0
0
Q l/min 50 100 150
55 0.25
η
η Pst
0.2
Pst Test results with clean cold water, without gas
45 content.
kW
% A safety margin of + 0.5 m is recommended for
0.1 the NPSH value.
35 0.05 Tolerances in accordance with UNI EN ISO 9906:2012
4
Head and power values valid for liquids with
NPSH 10 density ρ = 1,0 kg/dm3 and kinematic viscosity
ν = max 20 mm2/sec.
2 ft
MXV-B 32-403 4 2,3 MXV-BM 32-403 5,8 1,1 0,75 1 34 31 30,5 29 28 26,5 25 21 17 11,5
MXV-B 32-404/A 4,7 2,7 MXV-BM 32-404 7,4 1,5 1,1 1,5 45 41,5 40 38,5 36,5 34,5 32,5 27,5 22 14,5
MXV-B 32-405/A 4,7 2,7 MXV-BM 32-405 7,4 1,6 1,1 1,5 56 51,5 50 48 46 43,5 41 34,5 27,5 18,5
H
MXV-B 32-406/A 7,5 4,3 MXV-BM 32-406 9,2 2 1,5 2 68 62 60 58 55,5 52,5 49,5 42 33,5 22,5
m
MXV-B 32-407/A 7,5 4,3 MXV-BM 32-407 9,2 2,3 1,5 2 79,5 72,5 70,5 68 65 61,5 58 49 39 26,5
MXV-B 32-408/B 9,15 5,3 2,2 3 91 83 80,5 78 74 70 66 56 44,5 30
MXV-B 32-410/B 9,15 5,3 2,2 3 114 104 101 97,5 93 88 83 70 56 38
142
MXV-B 40-8 Vertical Multi-Stage Close Coupled Pumps
100
300
8
80 ft
7
H
m 6
60 200
5
4
40
3
100
20
0 0
0 m3/h 2 4 6 8 10 12 14
0
Q l/min 50 100 150 200
70 0.4
η Pst
Pst η
Test results with clean cold water, without gas
60 0.2
content.
% kW A safety margin of + 0.5 m is recommended for
the NPSH value.
50 0 Tolerances in accordance with UNI EN ISO 9906:2012
4
Head and power values valid for liquids with
10
NPSH density ρ = 1,0 kg/dm3 and kinematic viscosity
ft ν = max 20 mm2/sec.
2
MXV-B 40-803/A 4,7 2,7 MXV-BM 40-803 7,4 1,6 1,1 1,5 35,5 32,5 31,5 31 29,5 28 25,5 22,5 19,5 15,5
MXV-B 40-804/A 7,5 4,3 MXV-BM 40-804 9,2 2,3 1,5 2 47 43 42 41 40 37 34 30 26 21
MXV-B 40-805/B 9,15 5,3 2,2 3 59 54 53 51 50 47 43 38 32 26
H
MXV-B 40-806/B 9,15 5,3 2,2 3 71 65 63 62 59 56 51 45 39 31
m
MXV-B 40-807/A 11,5 6,6 3 4 83 76 74 72 69 66 60 53 45 36
MXV-B 40-808/A 11,5 6,6 3 4 95 87 85 82 79 75 69 60 51 42
MXV-B 40-810/B 9,6 3,7 5 119 109 106 103 99 94 86 75 64 52
143
MXV-B 50-18 Vertical Multi-Stage Close Coupled Pumps
400
120 MXV-B 50-1810
H
m
100
9
300
8
80 ft
7
6
60 200
5
4
40
3
100
20
0 0
0 m3/h 4 8 12 16 20 24 28
0
Q l/min 100 200 300 400
100 0.8
Pst
η Pst
Test results with clean cold water, without gas
60 0.4
η content.
% kW A safety margin of + 0.5 m is recommended for
the NPSH value.
20 0 Tolerances in accordance with UNI EN ISO 9906:2012
8
Head and power values valid for liquids with
NPSH 20 density ρ = 1,0 kg/dm3 and kinematic viscosity
ν = max 20 mm2/sec.
4 ft
MXV-B 50-1803/B 9,15 5,3 2,2 3 35,5 33,5 32 30 27,5 25,5 23,5 20,5 16,5 9
MXV-B 50-1804/A 11,5 6,6 3 4 48 46,5 44,5 41,5 38 36 33 29 23 14
MXV-B 50-1805/B 9,6 3,7 5 60 57,5 55 51,5 48 45 42 37,5 31,5 19
MXV-B 50-1806/B 9,6 4 5,5 71 68 65 61 56 53 49 44 36 22
H
MXV-B 50-1807/A 10,9 5,5 7,5 m 84 81,5 78 73,5 68 64,5 60 54 45 28
MXV-B 50-1808/A 10,9 5,5 7,5 94,5 92 88 82 76 72 68 60 50 32
MXV-B 50-1809/A 14,3 7,5 10 108 105 100 95 89 84 79 71 60 40
MXV-B 50-1810/A 14,3 7,5 10 120 117 112 106 98 94 88 78 67 44
144
MXV-B Vertical Multi-Stage Close Coupled Pumps
MXV-B(M) 25-208/A 1,5 2 G1 215 75 660 128 210 180 150 100 12,5 30 31
MXV-B(M) 25-210/A 1,5 2 G1 215 75 708 128 210 180 150 100 12,5 31 32
20 (25 MXV-B 50-18..)
(1)
(25 MXV-B 40-8..)
MXV-B(M) 32-403 0,75 1 G 1 1/4 215 75 564 128 210 180 150 100 12,5 24 25
MXV-B(M) 32-404/A 1,1 1,5 G 1 1/4 215 75 565 128 210 180 150 100 12,5 25 26
MXV-B(M) 32-405/A 1,1 1,5 G 1 1/4 215 75 588 128 210 180 150 100 12,5 26 27
G
MXV-B(M) 32-406/A 1,5 2 G 1 1/4 215 75 612 128 210 180 150 100 12,5 28 29
MXV-B(M) 32-407/A 1,5 2 G 1 1/4 215 75 636 128 210 180 150 100 12,5 29 30
MXV-B 32-408/B 2,2 3 G 1 1/4 215 75 700 128 210 180 150 100 12,5 34 -
h1
4.93.298
MXV-B 32-410/B 2,2 3 G 1 1/4 215 75 748 128 210 180 150 100 12,5 35 -
(2)
a MXV-B(M) 40-803/A 1,1 1,5 G 1 1/2 225 80 593 128 246 215 190 130 14 27 28
MXV-B(M) 40-804/A 1,5 2 G 1 1/2 225 80 593 128 246 215 190 130 14 28 29
MXV-B 40-805/B 2,2 3 G 1 1/2 225 80 663 128 246 215 190 130 14 33 -
MXV-B 40-806/B 2,2 3 G 1 1/2 225 80 693 128 246 215 190 130 14 34 -
MXV-B 40-807/A 3 4 G 1 1/2 225 80 746 138 246 215 190 130 14 45 -
n2
n1
MXV-B 40-808/A 3 4 G 1 1/2 225 80 776 138 246 215 190 130 14 49 -
MXV-B 40-810/B 3,7 5 G 1 1/2 225 80 953 138 246 215 190 130 14 49 -
s
MXV-B 50-1803/B 2,2 3 G2 250 90 635 128 246 215 190 130 14 34 -
MXV-B 50-1804/A 3 4 G2 250 90 701 138 246 215 190 130 14 44 -
m2
MXV-B 50-1805/B 3,7 5 G2 250 90 738 138 246 215 190 130 14 46,5 -
m1 MXV-B 50-1806/B 4 5,5 G2 250 90 776 138 246 215 190 130 14 47,5 -
(1)(1)
Filling
Riempimento MXV-B 50-1807/A 5,5 7,5 G2 250 90 841 160 246 215 190 130 14 59 -
(2)(2) Scarico
Draining MXV-B 50-1808/A 5,5 7,5 G2 250 90 878 160 246 215 190 130 14 60 -
(3)(3) Posizione
Standard standard
position scatola morsetti
of terminal box MXV-B 50-1809/A 7,5 10 G2 250 90 916 160 246 215 190 130 14 67 -
(for(altre
otherposizioni ruotando
positions rotateilmotor
motorethrough
di 90° o90°
180°)
or 180°) MXV-B 50-1810/A 7,5 10 G2 250 90 953 160 246 215 190 130 14 68 -
AD
Pump Motor
Motore mm Net
Pompa weight
P2
P2
kW HP G a h1 fM AD AG AS n1 n2 m1 m2 s kg
ISO 228
MXV-B EI 25-203 0,75 1 G1 215 75 564 286 190 105 210 180 150 100 12,5 29,4
MXV-B EI 25-204 0,75 1 G1 215 75 565 286 190 105 210 180 150 100 12,5 29,9
MXV-B EI 25-205 0,75 1 G1 215 75 588 286 190 105 210 180 150 100 12,5 30,9
MXV-B EI 25-206/A 1,1 1,5 G1 215 75 612 286 190 105 210 180 150 100 12,5 32,4
MXV-B EI 25-207/A 1,1 1,5 G1 215 75 636 286 190 105 210 180 150 100 12,5 33,4
fM
MXV-B EI 25-208/A 1,5 2 G1 215 75 660 286 190 105 210 180 150 100 12,5 36,4
(3)
MXV-B EI 25-210/A 1,5 2 G1 215 75 708 286 190 105 210 180 150 100 12,5 37,4
20 (25 MXV-B EI 40-8..)
(1) (4) MXV-B EI 32-403 0,75 1 G 1 1/4 215 75 564 286 190 105 210 180 150 100 12,5 30,4
MXV-B EI 32-404/A 1,1 1,5 G 1 1/4 215 75 565 286 190 105 210 180 150 100 12,5 31,4
MXV-B EI 32-405/A 1,1 1,5 G 1 1/4 215 75 588 286 190 105 210 180 150 100 12,5 32,4
MXV-B EI 32-406/A 1,5 2 G 1 1/4 215 75 612 286 190 105 210 180 150 100 12,5 34,4
G
MXV-B EI 32-407/A 1,5 2 G 1 1/4 215 75 636 286 190 105 210 180 150 100 12,5 35,4
MXV-B EI 32-408/B 2,2 3 G 1 1/4 215 75 700 286 210 118 210 180 150 100 12,5 41,5
h1
MXV-B EI 32-410/B 2,2 3 G 1 1/4 215 75 748 286 210 118 210 180 150 100 12,5 42,5
4.93.298
(2) MXV-B EI 40-803/A 1,1 1,5 G 1 1/2 225 80 593 286 190 105 246 215 190 130 14 33,4
a
MXV-B EI 40-804/A 1,5 2 G 1 1/2 225 80 593 286 190 105 246 215 190 130 14 34,4
MXV-B EI 40-805/B 2,2 3 G 1 1/2 225 80 663 286 190 105 246 215 190 130 14 40,5
MXV-B EI 40-806/B 2,2 3 G 1 1/2 225 80 693 286 190 105 246 215 190 130 14 41,5
MXV-B EI 40-807/A 3 4 G 1 1/2 225 80 746 294 210 118 246 215 190 130 14 52,5
n2
n1
AG
MXV-B EI 40-808/A 3 4 G 1 1/2 225 80 776 294 210 118 246 215 190 130 14 56,5
MXV-B EI 40-810/B 3,7 5 G 1 1/2 225 80 953 294 210 118 246 215 190 130 14 56,5
AS
MXV-B EI 50-1803/B 2,2 3 G2 250 90 635 286 210 118 246 215 190 130 14 41,5
s MXV-B EI 50-1804/A 3 4 G2 250 90 701 294 210 118 246 215 190 130 14 51,5
m2 MXV-B EI 50-1805/B 3,7 5 G2 250 90 738 294 210 118 246 215 190 130 14 54,0
m1 MXV-B EI 50-1806/B 4 5,5 G2 250 90 776 294 210 118 246 215 190 130 14 55,0
(1) Filling MXV-B EI 50-1807/A 5,5 7,5 G2 250 90 841 368 281 153 246 215 190 130 14 73,8
(2) Draining MXV-B EI 50-1808/A 5,5 7,5 G2 250 90 878 368 281 153 246 215 190 130 14 74,8
(3) Standard position of I-MAT MXV-B EI 50-1809/A 7,5 10 G2 250 90 916 368 281 153 246 215 190 130 14 81,8
(for other positions rotate motor through 90° or 180°)
MXV-B EI 50-1810/A 7,5 10 G2 250 90 953 368 281 153 246 215 190 130 14 82,8
(4) Pressure transducer
145
MXV-B Vertical Multi-Stage Close Coupled Pumps
Features
3.93.127
Low-Noise Operation
The water filled shroud around the stages and thick external walls, work together for low-
noise operation.
146
03/2021
Construction
Vertical multi-stage pumps with suction and delivery connections
of the same diameter and arranged along the same axis (in-line).
Corrosion-resistant bearing sleeves lubricated by the pumped liquid.
Removal of the mechanical seal without dismantling the motor
(for MXV 25-32-40-50,100 with motors exceeding 4 KW).
A pump with thrust bearing and sleeve coupling for use of any
standard motor with IM V1 construction.
Version with frequency converter (on request)
Applications
For water supply systems.
For clean non-explosive liquids, without solid, filamentary or
abrasive matter (with adaptation of sealing materials on request).
A universal pump for civil and industrial use, for pressure-boosting
systems, high-pressure washing plants, irrigation, agricultural
uses and sport installations.
Operating conditions
Temperature of liquid: from -15 °C to +110 °C (up to +120 °C
for MXV 50).
Operating environment temperature: up to 40 °C.
Maximum permissible pressure in pump casing: 25 bar.
(16 bar for pumps with oval flanges).
Continuous duty.
Motor
Standard-type: 2-pole induction motor, 50 Hz (n ≈ 2900 rpm).
Construction IM V1 (EN 60034-7).
Motor suitable for operation with frequency converter.
Classification scheme IE3 for three-phase motors.
Insulation class F. Protection IP 55.
three-phase with rated voltage: up to 3 kW 230/400 V;
The electropumps MXV series comply with the European Regulation no. 547/2012. from 4 kW 400/690 V.
147
MXV EI Vertical Multi-Stage In-Line Pumps
Advantages
- Energy saving
- Compact design
- Easy to use
- Programmable to suit the system requirements
- Reliability
Costruction
The system comprises of:
- Pump
- Induction motor
- I-MAT Frequency converter
- Motor adapter for the motor mounting of the frequency converter
- Connection cable between frequency converter and induction motor
- Transducers
Main features
Rated motor power output from 0,75 kW to 22 kW
Control range from 1750 to 2900 rpm (2-pole)
Protection against dry running
Protection against operations with closed connection ports
Protection against system leakages
Protection against overcurrent in the motor
Protection agains overvoltage and undervoltage of the power supply
Protection against current unbalances between phases
Operating modes
H
Mode at a constant pressure
with pressure sensor +
-
In this mode, the system maintains the preset pressure when the flow required by
the installation changes.
Q
H
Proportional pressure mode
with pressure sensor +
-
In this mode the system changes the working pressure according to the required
flow rate.
H
Constant flow mode
with flow meter
-
+
In this mode the system maintains a constant flow rate value in a point of the
installation according to the required pressure.
Q
H
Fixed speed mode
with setting of the speed preferential rotation. max
+
-
In this mode, by changing the working frequency, you may choose any operational
curve included within the working range. min
148
MXV Vertical Multi-Stage In-Line Pumps
Designation
MXV L EI 25 - 3 05 F H1 *
Series
AISI 316L vesion
(no code = AISI 304 vesion)
With frequency converter I-MAT
DN ports in mm
Rated capacity in m3/h (n ≈ 2900 rpm)
Number of stages
Construction variants
flanged ports F
oval flange ports (only for MXV(L) 25,32,40,50) O
with support feet for horizontal installation H, variant 1
with motor (or without motor)
* with no further designation = with standard motor
Variants
Varianti Installations
Installazioni
Vertical installation
Installazione verticale
4.93.213/1
(Standard).
(Standard).
149
MXV Vertical Multi-Stage In-Line Pumps
Coverage chart
4 5 Imp. g.p.m. 10 20 30 40 50 100 200 300 400 500
250
800
MXV
n≈ 2900 1/min
700
200
50-20 H
H
ft
m
50-15
150 500
400
100-65
100
300
100
0 0
1 m3 /h 2 3 4 5 6 7 8 9 10 16 20 32 40 48 60 70 80 90100 150
Q l/min 30 40 50 100 150 200 300 400 500 1000 1500 2000
72.936/1
150
MXV 25-3 Vertical Multi-Stage In-Line Pumps
MXV 25-320
220
700
200
18
600
180
16
H ft
m
14 500
140
12
120 400
10
100
300
8
80 7
6
60 200
5
4
40
100
20
0 0
0 m3/h 1 2 3 4 5
0
Q l/min 20 30 40 50 60 70 80
50 0.2
η Pst
Pst
40 0.1
η Test results with clean cold water, without gas
% kW content.
A safety margin of + 0.5 m is recommended for
30 0 the NPSH value.
4 Tolerances in accordance with UNI EN ISO 9906:2012
151
MXV 32-5 Vertical Multi-Stage In-Line Pumps
220
700
200
MXV 32-518
600
180
H ft
16
m
500
14
140
12 400
120
100
10
300
80
8
7
60 6 200
5
40
4
100
20
0 0
0 m /h3 2 3 4 5 6 7 8 9
0
Q l/min 50 100 150
55 0.25
η
η Pst
0.2
Pst
45 Test results with clean cold water, without gas
kW
% content.
0.1
A safety margin of + 0.5 m is recommended for
35 0.05 the NPSH value.
4 Tolerances in accordance with UNI EN ISO 9906:2012
152
MXV 40-9 Vertical Multi-Stage In-Line Pumps
200
17
600
180
H ft
15
m
500
13
140
120
11 400
10
100
8 300
80 7
6
60 200
5
4
40
100
20
0 0
0 m3/h 2 4 6 8 10 12 14
0
Q l/min 50 100 150 200
70 0.4
η Pst
Pst η
60 0.2 Test results with clean cold water, without gas
% kW content.
A safety margin of + 0.5 m is recommended for
50 0 the NPSH value.
4 Tolerances in accordance with UNI EN ISO 9906:2012
153
MXV 50-15 Vertical Multi-Stage In-Line Pumps
260
800
240 MXV 50-1517
220
16 700
200 15
14
180 600
13
H 12 ft
m
500
11
140
10
120 9 400
8
100
7 300
80 6
5
60 200
4
40 3
2 100
20
1
0 0
0 m 3/h 4 8 12 16 20 24
Q
0 l/min 100 150 200 250 300 350 400
80 1.0
η η Pst Pst
Test results with clean cold water, without gas
60 0.6 content.
% kW A safety margin of + 0.5 m is recommended for
the NPSH value.
40 0.2 Tolerances in accordance with UNI EN ISO 9906:2012
8
154
MXV 50-20 Vertical Multi-Stage In-Line Pumps
200 14
13
180 600
12
H ft
11
m
500
10
140
9
120 400
8
100 7
300
6
80
5
60 4 200
3
40
2 100
20
1
0 0
0 m 3/h 4 8 12 16 20 24 28
Q
0 l/min 100 150 200 250 300 350 400 450
80 1.0
Pst
η η Pst
Test results with clean cold water, without gas
60 0.6 content.
% kW A safety margin of + 0.5 m is recommended for
the NPSH value.
40 0.2 Tolerances in accordance with UNI EN ISO 9906:2012
8
20
Head and power values valid for liquids with
NPSH density ρ = 1,0 kg/dm3 and kinematic viscosity
ft
4 ν = max 20 mm2/sec.
10
m
Pst = Power with reference to one stage.
0 0 A* Calpeda motor currents
72.937
0 Q m 3/h 4 8 12 16 20 24 28
Motor power
Pump type 230 V 400 V m3/h 0 10 12 14 16 18 20 22 24 26 28
Q
A* A* kW HP l/min 0 166,6 200 233 266 300 333 366 400 433 466
MXV 50-2001 4,7 2,7 1,1 1,5 15,5 13,0 12,6 12,1 11,5 10,7 9,8 8,7 7,3 5,8 4,0
MXV 50-2002 9,2 5,3 2,2 3 30,7 27,0 26,3 25,5 24,5 23,3 21,7 19,8 17,5 14,7 11,7
MXV 50-2003 11,4 6,6 3 4 46,5 41,4 40,4 39,1 37,5 35,4 32,9 30,0 26,5 22,5 18,0
MXV 50-2004 9,6 4 5,5 62,5 56,0 54,5 53,0 51,0 48,5 45,5 42,0 37,5 32,0 26,0
MXV 50-2005 10,9 5,5 7,5 78,0 70,0 68,0 66,0 64,0 61,0 57,0 52,5 46,5 40,0 32,5
MXV 50-2006 14,3 7,5 10 92,0 84,0 82,0 79,5 76,5 73,0 68,5 62,5 55,5 47,0 37,5
MXV 50-2007 14,3 7,5 10 107,0 98,0 95,5 93,0 89,5 85,0 80,0 73,0 64,5 55,0 44,0
MXV 50-2008 18,5 9,2 12,5 H 122 112 109 106 102 97 91 83 74 63 50
MXV 50-2009 18,5 9,2 12,5 m 142 130 127 124 120 114 108 100 89 77 63
MXV 50-2010 21,5 11 15 158 144 141 137 133 127 120 111 99 86 71
MXV 50-2011 21,5 11 15 173 159 155 151 146 140 132 122 109 94 78
MXV 50-2012 27,3 15 20 188 172 168 164 158 151 143 132 118 103 84
MXV 50-2013 27,3 15 20 204 186 182 177 171 164 154 143 128 111 91
MXV 50-2014 27,3 15 20 219 201 196 191 185 177 166 154 138 120 99
MXV 50-2015 27,3 15 20 235 215 210 205 198 189 178 165 148 128 106
MXV 50-2016 34 18,5 25 251 232 227 221 214 205 193 179 161 140 116
MXV 50-2017 34 18,5 25 267 246 241 235 227 217 205 190 172 149 124
155
MXV 65-32 Vertical Multi-Stage In-Line Pumps
MXV 65-3212
220
700
200
600
180
10
H ft
m 9
500
140 8
7 400
120
6
100
5 300
80
4
60 200
3
40 2
100
20
0 0
0 m3/h 10 20 30 40 50
0
Q l/min 200 300 400 500 600 700 800
80 2
Pst
η Pst
60 η 1
Test results with clean cold water, without gas
% kW content.
A safety margin of + 0.5 m is recommended for
40 0 the NPSH value.
8 Tolerances in accordance with UNI EN ISO 9906:2012
NPSH 20
Head and power values valid for liquids with
ft density ρ = 1,0 kg/dm3 and kinematic viscosity
4
10 ν = max 20 mm2/sec.
m
Pst = Power with reference to one stage.
0 0 A* Calpeda motor currents
72.974
3
0 Q m /h 10 20 30 40 50
156
MXV 80-48 Vertical Multi-Stage In-Line Pumps
600
180
160
ft
H MXV 80-4808 500
m
140
7
120 400
6
100
5 300
80
4
60 200
3
40 2
100
20 1
0 0
0 m3/h 10 20 30 40 50 60
Q l/min 200
0 300 400 500 600 700 800 900 1000
80
70 4
η% η Pst
60 3 Test results with clean cold water, without gas
Pst kW
50 2
content.
A safety margin of + 0.5 m is recommended for
40 1 the NPSH value.
6 ft Tolerances in accordance with UNI EN ISO 9906:2012
NPSH
ft Head and power values valid for liquids with
4
10
density ρ = 1,0 kg/dm3 and kinematic viscosity
m
ν = max 20 mm2/sec.
2
Motor power
Pump type 230 V 400 V m3/h 0 21 27 33 39 45 48 51 54 60
Q
A* A* kW HP l/min 0 350 450 550 650 750 800 850 900 1000
MXV 80-4801/D 9,6 4 5,5 20 18 17 16 15 13 12 10,7 9,5 7
MXV 80-4802/C 10,9 5,5 7,5 40,5 36 34,5 32,5 29,5 26,5 24,5 22 20 15,5
MXV 80-4803/C 14,3 7,5 10 61 54 51 48 44 40 37 34 31 24,5
MXV 80-4804/D 21,5 11 15 H 81 72 69 65 60 55 51,5 48 44 35
MXV 80-4805/D 27,3 15 20 m 101 90 86 81 75 68,5 64,5 60 55 44
MXV 80-4806/D 27,3 15 20 121 108 103 97 90 82 77,5 72 66 53
MXV 80-4807/E 34 18,5 25 142 126 120 113 105 96 90 84 77 61,5
MXV 80-4808/D 41 22 30 162 144 137 129 120 109 103 96 88 70,5
157
MXV 100-65 Vertical Multi-Stage In-Line Pumps
MXV 100-65
220
700
8
200
8-2R
600
180 7
H ft
7-2R
m 6 500
140 6-2R
5
120 400
5-2R
100 4
300
4-2R
80
3
60 3-2R 200
2
40
2-2R
100
1
20
0 0
0 m3/h 20 40 60 80 100
0
Q l/min 400 600 800 1000 1200 1400 1600
100 8
80 6
η% η Pst Test results with clean cold water, without gas
60 Pst 4 content.
kW A safety margin of + 0.5 m is recommended for
40 Pst R
2
the NPSH value.
20 0 Tolerances in accordance with UNI EN ISO 9906:2012
12
NPSH Head and power values valid for liquids with
8 ft density ρ = 1,0 kg/dm3 and kinematic viscosity
m 10 ν = max 20 mm2/sec.
4
Pst = Power with reference to one stage.
A* Calpeda motor currents
0 0
72.974
3
0 Q m /h 20 40 60 80 100
158
MXV 100-90 Vertical Multi-Stage In-Line Pumps
6
160
ft
H 6-2R 500
m
140 5
5-2R
120 400
4
100 4-2R
300
3
80
3-2R
60 200
2
2-2R
40
1 100
20
1-1R
0 0
0 m3/h 20 40 60 80 100 120
Q l/min 400
0 600 800 1000 1200 1400 1600 1800 2000
100 10
80 η 8
η% Pst
Pst
60 6
Pst R kW Test results with clean cold water, without gas
40 4 content.
A safety margin of + 0.5 m is recommended for
20 2 the NPSH value.
12 ft Tolerances in accordance with UNI EN ISO 9906:2012
NPSH
8 ft Head and power values valid for liquids with
m 10 density ρ = 1,0 kg/dm3 and kinematic viscosity
4
ν = max 20 mm2/sec.
159
25-3
32-5
MXV 40-9 Vertical Multi-Stage In-Line Pumps
M
(4)
P
G 1/4
d
G 1/4 G 1/4
(1) (1) (1) Flanges EN 1092-1 PN 25 - 40
fM
Holes
f DN DE DK DG N. Ø
G 3/8 G 3/8 25 115 85 65 4 14
(2) (3) 32 140 100 76 4 19
DN
DN 40 150 110 84 4 19
h1
4.93.210/2
g1
a
G 3/8
(1) Filling and air vent (2) G 1/4
(1)
(2) Air vent suction side
(3) Draining
n2
n1
200
(for other positions rotate motor through 90° or 180°)
Ø15
(5) MXV (H) : + 3 kg G 3/8
(3)
s 15 130
(6) With standard motor 40 170
m2
(7) Net weight
m1 m4
without with
Pump Motor mm motor motor
(5) (5)
(6) (6) (7) (7)
kW HP DN a h1 f n1 n2 m1 m2 s g1 M fM P AD m4 kg kg
MXV 25-304 0,75 1 M80 V1 25 250 75 382,5 205 180 165 100 13 35,5 255 637,5 200 127,5 283 - -
MXV 25-305 0,75 1 M80 V1 25 250 75 406,5 205 180 165 100 13 35,5 255 661,5 200 127,5 307
MXV 25-306 1,1 1,5 M80 V1 25 250 75 430,5 205 180 165 100 13 35,5 255 685,5 200 127,5 331
MXV 25-307 1,1 1,5 M80 V1 25 250 75 454,5 205 180 165 100 13 35,5 255 709,5 200 127,5 355
MXV 25-308 1,5 2 M90 V1 25 250 75 478,5 205 180 165 100 13 35,5 255 733,5 200 127,5 379
MXV 25-310 1,5 2 M90 V1 25 250 75 527 205 180 165 100 13 35,5 255 782 200 127,5 427,5
MXV 25-312 2,2 3 M90 V1 25 250 75 575,5 205 180 165 100 13 35,5 295 870,5 200 127,5 476
MXV 25-314 2,2 3 M90 V1 25 250 75 623,5 205 180 165 100 13 35,5 295 918,5 200 127,5 524
MXV 25-316 3 4 M100 V1 25 250 75 672 205 180 165 100 13 35,5 311 983 250 137,5 572,5
MXV 25-318 3 4 M100 V1 25 250 75 720,5 205 180 165 100 13 35,5 311 1031,5 250 137,5 621
MXV 25-320 3 4 M100 V1 25 250 75 768,5 205 180 165 100 13 35,5 311 1079,5 250 137,5 669
MXV 32-504 1,1 1,5 M80 V1 32 250 75 382,5 205 180 165 100 13 35,5 255 637,5 200 127,5 283
MXV 32-505 1,1 1,5 M80 V1 32 250 75 406,5 205 180 165 100 13 35,5 255 661,5 200 127,5 307
MXV 32-506 1,5 2 M90 V1 32 250 75 430,5 205 180 165 100 13 35,5 255 685,5 200 127,5 331
MXV 32-507 1,5 2 M90 V1 32 250 75 454,5 205 180 165 100 13 35,5 255 709,5 200 127,5 355
MXV 32-508 2,2 3 M90 V1 32 250 75 478,5 205 180 165 100 13 35,5 295 773,5 200 127,5 379
MXV 32-510 2,2 3 M90 V1 32 250 75 527 205 180 165 100 13 35,5 295 822 200 127,5 427,5
MXV 32-512 3 4 M100 V1 32 250 75 575,5 205 180 165 100 13 35,5 311 886,5 250 137,5 476
MXV 32-514 3 4 M100 V1 32 250 75 623,5 205 180 165 100 13 35,5 311 934,5 250 137,5 524
MXV 32-516 4 5,5 M112 V1 32 250 75 672 205 180 165 100 13 35,5 311 983 250 137,5 572,5
MXV 32-518 4 5,5 M112 V1 32 250 75 720,5 205 180 165 100 13 35,5 311 1031,5 250 137,5 621
MXV40-904 1,5 2 M90 V1 40 280 80 411,5 250 215 190 130 14 30,5 255 666,5 200 127,5 312
MXV 40-905 2,2 3 M90 V1 40 280 80 441,5 250 215 190 130 14 30,5 295 736,5 200 127,5 342
MXV 40-906 2,2 3 M90 V1 40 280 80 471,5 250 215 190 130 14 30,5 295 766,5 200 127,5 372
MXV 40-907 3 4 M100 V1 40 280 80 501,5 250 215 190 130 14 30,5 311 812,5 250 137,5 402
MXV 40-908 3 4 M100 V1 40 280 80 532 250 215 190 130 14 30,5 311 843 250 137,5 432,5
MXV 40-910 4 5,5 M112 V1 40 280 80 592 250 215 190 130 14 30,5 311 903 250 137,5 492,5
MXV 40-911 4 5,5 M112 V1 40 280 80 622 250 215 190 130 14 30,5 311 933 250 137,5 522,5
MXV 40-913 5,5 7,5 M132 V1 40 280 80 769,5 250 215 190 130 14 30,5 339 1108,5 300 159,5 583,5
MXV 40-915 5,5 7,5 M132 V1 40 280 80 830 250 215 190 130 14 30,5 339 1169 300 159,5 644
MXV 40-917 7,5 10 M132 V1 40 280 80 890 250 215 190 130 14 30,5 339 1229 300 159,5 704
MXV 40-919 7,5 10 M132 V1 40 280 80 950 250 215 190 130 14 30,5 339 1289 300 159,5 764
160
25-3
32-5
MXV 40-9 Vertical Multi-Stage In-Line Pumps
DN
G
(4) 40 1 1/2 26 2 15
P
G 3/8 G 3/8 DN DE
(2) (3)
h1
4.93.210/2
g1
a
G 3/8
(1) Filling and air vent (2) G 1/4
(1)
(2) Air vent suction side
(3) Draining
n2
n1
200
(for other positions rotate motor through 90° or 180°)
Ø15
(5) MXV (H) : + 3 kg G 3/8
(3)
15 130
s
(6) With standard motor 40 170
m2
(7) Net weight
m1 m4
without with
Pump Motor mm motor motor
(5) (5) (6)
(6) (6) (7) (7)
kW HP DN ao h1 f n1 n2 m1 m2 s g1 M fM P AD m4 kg kg
MXV 25-304 O 0,75 1 M80 V1 25 160 50 367 205 180 165 100 13 20 255 622 200 127,5 268 - -
MXV 25-305 O 0,75 1 M80 V1 25 160 50 391 205 180 165 100 13 20 255 646 200 127,5 292
MXV 25-306 O 1,1 1,5 M80 V1 25 160 50 415 205 180 165 100 13 20 255 670 200 127,5 316
MXV 25-307 O 1,1 1,5 M80 V1 25 160 50 439 205 180 165 100 13 20 255 694 200 127,5 340
MXV 25-308 O 1,5 2 M90 V1 25 160 50 463 205 180 165 100 13 20 255 718 200 127,5 364
MXV 25-310 O 1,5 2 M90 V1 25 160 50 511,5 205 180 165 100 13 20 255 766,5 200 127,5 412,5
MXV 25-312 O 2,2 3 M90 V1 25 160 50 560 205 180 165 100 13 20 295 855 200 127,5 461
MXV 25-314 O 2,2 3 M90 V1 25 160 50 608 205 180 165 100 13 20 295 903 200 127,5 509
MXV 32-504 O 1,1 1,5 M80 V1 32 160 50 367 205 180 165 100 13 20 255 622 200 127,5 267,5
MXV 32-505 O 1,1 1,5 M80 V1 32 160 50 391 205 180 165 100 13 20 255 646 200 127,5 291,5
MXV 32-506 O 1,5 2 M90 V1 32 160 50 415 205 180 165 100 13 20 255 670 200 127,5 315,5
MXV 32-507 O 1,5 2 M90 V1 32 160 50 439 205 180 165 100 13 20 255 694 200 127,5 339,5
MXV 32-508 O 2,2 3 M90 V1 32 160 50 463 205 180 165 100 13 20 295 758 200 127,5 363,5
MXV 32-510 O 2,2 3 M90 V1 32 160 50 511,5 205 180 165 100 13 20 295 806,5 200 127,5 412
MXV 32-512 O 3 4 M100 V1 32 160 50 560 205 180 165 100 13 20 311 871 250 137,5 460,5
MXV 32-514 O 3 4 M100 V1 32 160 50 608 205 180 165 100 13 20 311 919 250 137,5 508,5
MXV40-904 O 1,5 2 M90 V1 40 200 80 411,5 250 215 190 130 14 30,5 255 666,5 200 127,5 312
MXV 40-905 O 2,2 3 M90 V1 40 200 80 441,5 250 215 190 130 14 30,5 295 736,5 200 127,5 342
MXV 40-906 O 2,2 3 M90 V1 40 200 80 471,5 250 215 190 130 14 30,5 295 766,5 200 127,5 372
MXV 40-907 O 3 4 M100 V1 40 200 80 501,5 250 215 190 130 14 30,5 311 812,5 250 137,5 402
MXV 40-908 O 3 4 M100 V1 40 200 80 532 250 215 190 130 14 30,5 311 843 250 137,5 432,5
MXV 40-910 O 4 5,5 M112 V1 40 200 80 592 250 215 190 130 14 30,5 311 903 250 137,5 492,5
MXV 40-911 O 4 5,5 M112 V1 40 200 80 622 250 215 190 130 14 30,5 311 933 250 137,5 522,5
MXV 40-913 O 5,5 7,5 M132 V1 40 200 80 769,5 250 215 190 130 14 30,5 339 1108,5 300 159,5 583,5
161
50-15
MXV 50-20 Vertical Multi-Stage In-Line Pumps
d
(1) (1) (1)
fM Flanges EN 1092-2 ENPN 25
1092-2 PN 25
Holes
DN DE DK DG
N. Ø
G 3/8 G 3/8 50 165 125 99 4 19
(2) (3)
DN
DN
h1
4.93.210/2
25
a
G 3/8
(1) Filling and air vent (2) G 1/4
(1)
(2) Air vent suction side
(3) Draining
215
250
200
(for other positions rotate motor through 90° or 180°) Ø15
G 3/8
(5) (H) : + 3 kg (3)
13 15 130
(6) With standard motor
(7) Net weight 130 40 170
196 m4
without with
Pump Motor mm motor motor
MXV (5) (6)
(6) (6) (7) (7)
kW HP DN a h1 f M fM P AD m4 kg kg
MXV 50-1501 1,1 1,5 M80 V1 50 300 90 438 255 693 200 127,5 313 27,4 40,7
MXV 50-1502 1,5 2 M90 V1 50 300 90 438 255 693 200 127,5 313 27,9 41,2
MXV 50-1503/A 2,2 3 M90 V1 50 300 90 486 311 797 200 137,5 361 29,4 55,0
MXV 50-1504 3 4 M100 V1 50 300 90 534 311 845 250 137,5 409 31,8 57,4
MXV 50-1505 4 5,5 M112 V1 50 300 90 582 311 893 250 137,5 457 33,3 61,1
MXV 50-1506 5,5 7,5 M132 V1 50 300 90 693 339 1032 300 159,5 505 44,3 86,6
MXV 50-1507 5,5 7,5 M132 V1 50 300 90 741 339 1080 300 159,5 553 45,7 88,0
MXV 50-1508/A 5,5 7,5 M132 V1 50 300 90 789 339 1128 300 159,5 601 47,2 94,9
MXV 50-1509 7,5 10 M132 V1 50 300 90 837 339 1176 300 159,5 649 48,6 96,3
MXV 50-1510 7,5 10 M132 V1 50 300 90 885 339 1224 300 159,5 697 50,1 97,8
MXV 50-1511 9,2 12,5 M160 V1 50 300 90 963 413 1376 350 186 745 58,0 128
MXV 50-1512 9,2 12,5 M160 V1 50 300 90 1011 413 1424 350 186 793 59,3 129,3
MXV 50-1513 11 15 M160 V1 50 300 90 1059 459 1518 350 186 841 60,7 136,7
MXV 50-1514 11 15 M160 V1 50 300 90 1107 459 1566 350 186 889 62,2 138,2
MXV 50-1515 11 15 M160 V1 50 300 90 1155 459 1614 350 186 937 63,7 139,7
MXV 50-1516 15 20 M160 V1 50 300 90 1203 484 1687 350 186 985 65,1 167,1
MXV 50-1517 15 20 M160 V1 50 300 90 1251 484 1735 350 186 1033 66,6 168,6
MXV 50-2001 1,1 1,5 M80 V1 50 300 90 438 255 693 200 127,5 313 27,4 40,7
MXV 50-2002 2,2 3 M90 V1 50 300 90 438 295 733 200 127,5 313 27,9 46,0
MXV 50-2003 3 4 M100 V1 50 300 90 486 311 797 250 137,5 361 30,3 55,9
MXV 50-2004 4 5,5 M112 V1 50 300 90 534 311 845 250 137,5 409 31,8 59,6
MXV 50-2005 5,5 7,5 M132 V1 50 300 90 645 339 984 300 159,5 457 42,8 85,1
MXV 50-2006 7,5 10 M132 V1 50 300 90 693 339 1032 300 159,5 505 44,3 92,0
MXV 50-2007 7,5 10 M132 V1 50 300 90 741 339 1080 300 159,5 553 45,7 93,4
MXV 50-2008 9,2 12,5 M160 V1 50 300 90 819 413 1232 350 186 601 53,5 123,5
MXV 50-2009 9,2 12,5 M160 V1 50 300 90 867 413 1280 350 186 649 54,9 124,9
MXV 50-2010 11 15 M160 V1 50 300 90 915 459 1374 350 186 697 56,4 132,4
MXV 50-2011 11 15 M160 V1 50 300 90 963 459 1422 350 186 745 57,8 133,8
MXV 50-2012 15 20 M160 V1 50 300 90 1011 484 1495 350 186 793 59,3 161,3
MXV 50-2013 15 20 M160 V1 50 300 90 1059 484 1543 350 186 841 60,7 162,7
MXV 50-2014 15 20 M160 V1 50 300 90 1107 484 1591 350 186 889 62,2 164,2
MXV 50-2015 15 20 M160 V1 50 300 90 1155 484 1639 350 186 937 63,7 165,7
MXV 50-2016 18,5 25 M160 V1 50 300 90 1203 538 1741 350 206 985 65,1 187,1
MXV 50-2017 18,5 25 M160 V1 50 300 90 1251 538 1789 350 206 1033 66,6 188,6
162
50-15
MXV 50-20 Vertical Multi-Stage In-Line Pumps
M Oval Counterflanges
(4)
P 34
DN 50
G2
G 1/4 G 1/4 G 1/4
(1) (1) (1)
fM
Oval Flanges
N. 2 M 12
f
G 3/8 G 3/8
(2) (3)
DN
DN DN 50
100
130
h1
4.93.210/2
25
a
G 3/8
(1) Filling and air vent (2) G 1/4
(1)
(2) Air vent suction side
(3) Draining
215
250
200
(for other positions rotate motor through 90° or 180°) Ø15
G 3/8
(5) (H) : + 3 kg (3)
13 15 130
(6) With standard motor
(7) Net weight 130 40 170
196 m4
without with
Pump Motor mm motor motor
MXV (5) (6)
(6) (6) (7) (7)
kW HP DN a h1 f M fM P AD m4 kg kg
MXV 50-1501 O 1,1 1,5 M80 V1 50 200 90 438 255 693 200 127,5 313 24,6 37,9
MXV 50-1502 O 1,5 2 M90 V1 50 200 90 438 255 693 200 127,5 313 25,1 38,4
MXV 50-1503/A O 2,2 3 M90 V1 50 200 90 486 311 797 200 137,5 361 26,6 52,2
MXV 50-1504 O 3 4 M100 V1 50 200 90 534 311 845 250 137,5 409 29,0 54,6
MXV 50-1505 O 4 5,5 M112 V1 50 200 90 582 311 893 250 137,5 457 30,5 58,3
MXV 50-1506 O 5,5 7,5 M132 V1 50 200 90 693 339 1032 300 159,5 505 41,5 83,8
MXV 50-1507 O 5,5 7,5 M132 V1 50 200 90 741 339 1080 300 159,5 553 42,9 85,2
MXV 50-1508/A O 5,5 7,5 M132 V1 50 200 90 789 339 1128 300 159,5 601 44,4 86,7
MXV 50-1509 O 7,5 10 M132 V1 50 200 90 837 339 1176 300 159,5 649 45,8 93,5
MXV 50-1510 O 7,5 10 M132 V1 50 200 90 885 339 1224 300 159,5 697 47,3 95,0
MXV 50-2001 O 1,1 1,5 M80 V1 50 200 90 438 255 693 200 127,5 313 24,6 37,9
MXV 50-2002 O 2,2 3 M90 V1 50 200 90 438 295 733 200 127,5 313 25,1 43,2
MXV 50-2003 O 3 4 M100 V1 50 200 90 486 311 797 250 137,5 361 27,6 53,2
MXV 50-2004 O 4 5,5 M112 V1 50 200 90 534 311 832 250 137,5 409 29,0 56,8
MXV 50-2005 O 5,5 7,5 M132 V1 50 200 90 645 339 984 300 159,5 457 40,0 82,3
MXV 50-2006 O 7,5 10 M132 V1 50 200 90 693 339 1032 300 159,5 505 41,5 89,2
MXV 50-2007 O 7,5 10 M132 V1 50 200 90 741 339 1080 300 159,5 553 42,9 90,6
MXV 50-2008 O 9,2 12,5 M160 V1 50 200 90 819 413 1232 350 186 601 50,7 120,7
MXV 50-2009 O 9,2 12,5 M160 V1 50 200 90 867 413 1280 350 186 649 52,1 122,1
MXV 50-2010 O 11 15 M160 V1 50 200 90 915 459 1374 350 186 697 53,6 129,6
163
65-32
MXV 80-48 Vertical Multi-Stage In-Line Pumps
M DN
(4)
DG
P DK
DE
Flanges EN 1092-2 PN 25 - 40
G 3/8
(1) Holes
fM
DN DE DK DG
N. Ø
f G 1/8 65 185 145 118 8 19
(2) 80 200 160 132 8 19
G 3/8 G 3/8 DN DN
(3) (3)
h1
4.93.210/2
35
200
(1) Filling and air vent Ø14
(2) Air vent suction side G 3/8 (3) 4.93.210/3
without with
Pump Motor mm motor motor
164
100-65
MXV 100-90 Vertical Multi-Stage In-Line Pumps
M
P
(3)
fM
(1) (1)
f
Flanges EN 1092-2
DN DN
Holes
DN DN PN DE DK
N. Ø
DK
140
n1
N. 4 x Ø15
m2
m1
without with
Pump Motor mm motor motor
165
25-3
32-5
MXV EI 40-9 Vertical Multi-Stage In-Line Pumps
d
G 1/4 G 1/4 G 1/4 (7) Flanges EN 1092-1 PN 25 - 40
(1) (1) (4) (1)
fM
Holes
G 3/8 DN DE DK DG N. Ø
f (2)
G 3/8 G 3/8 25 115 85 65 4 14
(2) (3) 32 140 100 76 4 19
DN
DN
40 150 110 84 4 19
h1
4.93.210/2
g1
a
G 3/8 (4)
(1) Filling and air vent (2) G 1/4
(2) Air vent suction side (1)
(3) Draining
n2
n1
200
AS Ø15
(6) Net weight G 3/8
(3)
(7) Pressure transducer 15 130
s
m2 40 170
(4) Standard position of I-MAT.
(for other positions rotate motor through 90° or 180°) m1 m4
Pump Motor mm
(5)
(6)
kW HP DN a h1 f n1 n2 m1 m2 s g1 M fM P AD AG AS m4 kg
MXV EI 25-304 0,75 1 M80 V1 25 250 75 382,5 205 180 165 100 13 35,5 255 637,5 200 286 190 105 283 -
MXV EI 25-305 0,75 1 M80 V1 25 250 75 406,5 205 180 165 100 13 35,5 255 661,5 200 286 190 105 307
MXV EI 25-306 1,1 1,5 M80 V1 25 250 75 430,5 205 180 165 100 13 35,5 255 685,5 200 286 190 105 331
MXV EI 25-307 1,1 1,5 M80 V1 25 250 75 454,5 205 180 165 100 13 35,5 255 709,5 200 286 190 105 355
MXV EI 25-308 1,5 2 M90 V1 25 250 75 478,5 205 180 165 100 13 35,5 255 733,5 200 286 190 105 379
MXV EI 25-310 1,5 2 M90 V1 25 250 75 527 205 180 165 100 13 35,5 255 782 200 286 190 105 427,5
MXV EI 25-312 2,2 3 M90 V1 25 250 75 575,5 205 180 165 100 13 35,5 295 870,5 200 286 210 118 476
MXV EI 25-314 2,2 3 M90 V1 25 250 75 623,5 205 180 165 100 13 35,5 295 918,5 200 286 210 118 524
MXV EI 25-316 3 4 M100 V1 25 250 75 672 205 180 165 100 13 35,5 311 983 250 294 210 118 572,5
MXV EI 32-504 1,1 1,5 M80 V1 32 250 75 382,5 205 180 165 100 13 35,5 255 637,5 200 286 190 105 283
MXV EI 32-505 1,1 1,5 M80 V1 32 250 75 406,5 205 180 165 100 13 35,5 255 661,5 200 286 190 105 307
MXV EI 32-506 1,5 2 M90 V1 32 250 75 430,5 205 180 165 100 13 35,5 255 685,5 200 286 190 105 331
MXV EI 32-507 1,5 2 M90 V1 32 250 75 454,5 205 180 165 100 13 35,5 255 709,5 200 286 190 105 355
MXV EI 32-508 2,2 3 M90 V1 32 250 75 478,5 205 180 165 100 13 35,5 295 773,5 200 286 210 118 379
MXV EI 32-510 2,2 3 M90 V1 32 250 75 527 205 180 165 100 13 35,5 295 822 200 286 210 118 427,5
MXV EI 32-512 3 4 M100 V1 32 250 75 575,5 205 180 165 100 13 35,5 311 886,5 250 294 210 118 476
MXV EI 32-514 3 4 M100 V1 32 250 75 623,5 205 180 165 100 13 35,5 311 934,5 250 294 210 118 524
MXV EI 32-516 4 5,5 M112 V1 32 250 75 672 205 180 165 100 13 35,5 311 983 250 294 210 118 572,5
MXV EI 40-904 1,5 2 M90 V1 40 280 80 411,5 250 215 190 130 14 30,5 255 666,5 200 286 190 105 312
MXV EI 40-905 2,2 3 M90 V1 40 280 80 441,5 250 215 190 130 14 30,5 295 736,5 200 286 210 118 342
MXV EI 40-906 2,2 3 M90 V1 40 280 80 471,5 250 215 190 130 14 30,5 295 766,5 200 286 210 118 372
MXV EI 40-907 3 4 M100 V1 40 280 80 501,5 250 215 190 130 14 30,5 311 812,5 250 294 210 118 402
MXV EI 40-908 3 4 M100 V1 40 280 80 532 250 215 190 130 14 30,5 311 843 250 294 210 118 432,5
MXV EI 40-910 4 5,5 M112 V1 40 280 80 592 250 215 190 130 14 30,5 311 903 250 294 210 118 492,5
MXV EI 40-911 4 5,5 M112 V1 40 280 80 622 250 215 190 130 14 30,5 311 933 250 294 210 118 522,5
MXV EI 40-913 5,5 7,5 M132 V1 40 280 80 769,5 250 215 190 130 14 30,5 339 1108,5 300 321 210 118 583,5
MXV EI 40-915 5,5 7,5 M132 V1 40 280 80 830 250 215 190 130 14 30,5 339 1169 300 321 210 118 644
166
25-3
32-5
MXV EI 40-9 Vertical Multi-Stage In-Line Pumps
DN
G
M 40 1 1/2 26 2 15
G 3/8 G 3/8 DN DE
(2) (3)
h1
4.93.210/2
g1
a
G 3/8 (4)
(1) Filling and air vent (2) G 1/4
(1)
(2) Air vent suction side
(3) Draining
n2
n1
200
AS Ø15
G 3/8
(6) Net weight (3)
(7) Pressure transducer s 15 130
m2 40 170
(4) Standard position of I-MAT.
(for other positions rotate motor through 90° or 180°) m1 m4
Pump Motor mm
(5)
(6)
kW HP DN a h1 f n1 n2 m1 m2 s g1 M fM P AD AG AS m4 kg
MXV EI 25-304 O 0,75 1 M80 V1 25 160 50 367 205 180 165 100 13 20 255 622 200 286 190 105 268 -
MXV EI 25-305 O 0,75 1 M80 V1 25 160 50 391 205 180 165 100 13 20 255 646 200 286 190 105 292
MXV EI 25-306 O 1,1 1,5 M80 V1 25 160 50 415 205 180 165 100 13 20 255 670 200 286 190 105 316
MXV EI 25-307 O 1,1 1,5 M80 V1 25 160 50 439 205 180 165 100 13 20 255 694 200 286 190 105 340
MXV EI 25-308 O 1,5 2 M90 V1 25 160 50 463 205 180 165 100 13 20 255 718 200 286 190 105 364
MXV EI 25-310 O 1,5 2 M90 V1 25 160 50 511,5 205 180 165 100 13 20 255 766,5 200 286 190 105 412,5
MXV EI 25-312 O 2,2 3 M90 V1 25 160 50 560 205 180 165 100 13 20 295 855 200 286 210 118 461
MXV EI 25-314 O 2,2 3 M90 V1 25 160 50 608 205 180 165 100 13 20 295 903 200 286 210 118 509
MXV EI 32-504 O 1,1 1,5 M80 V1 32 160 50 367 205 180 165 100 13 20 255 622 200 286 190 105 267,5
MXV EI 32-505 O 1,1 1,5 M80 V1 32 160 50 391 205 180 165 100 13 20 255 646 200 286 190 105 291,5
MXV EI 32-506 O 1,5 2 M90 V1 32 160 50 415 205 180 165 100 13 20 255 670 200 286 190 105 315,5
MXV EI 32-507 O 1,5 2 M90 V1 32 160 50 439 205 180 165 100 13 20 255 694 200 286 190 105 339,5
MXV EI 32-508 O 2,2 3 M90 V1 32 160 50 463 205 180 165 100 13 20 295 758 200 286 210 118 363,5
MXV EI 32-510 O 2,2 3 M90 V1 32 160 50 511,5 205 180 165 100 13 20 295 806,5 200 286 210 118 412
MXV EI 32-512 O 3 4 M100 V1 32 160 50 560 205 180 165 100 13 20 311 871 250 294 210 118 460,5
MXV EI 32-514 O 3 4 M100 V1 32 160 50 608 205 180 165 100 13 20 311 919 250 294 210 118 508,5
MXV EI 40-904 O 1,5 2 M90 V1 40 200 80 411,5 250 215 190 130 14 30,5 255 666,5 200 286 190 105 312
MXV EI 40-905 O 2,2 3 M90 V1 40 200 80 441,5 250 215 190 130 14 30,5 295 736,5 200 286 210 118 342
MXV EI 40-906 O 2,2 3 M90 V1 40 200 80 471,5 250 215 190 130 14 30,5 295 766,5 200 286 210 118 372
MXV EI 40-907 O 3 4 M100 V1 40 200 80 501,5 250 215 190 130 14 30,5 311 812,5 250 294 210 118 402
MXV EI 40-908 O 3 4 M100 V1 40 200 80 532 250 215 190 130 14 30,5 311 843 250 294 210 118 432,5
MXV EI 40-910 O 4 5,5 M112 V1 40 200 80 592 250 215 190 130 14 30,5 311 903 250 294 210 118 492,5
MXV EI 40-911 O 4 5,5 M112 V1 40 200 80 622 250 215 190 130 14 30,5 311 933 250 294 210 118 522,5
MXV EI 40-913 O 5,5 7,5 M132 V1 40 200 80 769,5 250 215 190 130 14 30,5 339 1108,5 300 321 210 118 583,5
167
50-15
MXV EI 50-20 Vertical Multi-Stage In-Line Pumps
Oval
d
Counterflanges G 1/4 (7)
G 1/4 G 1/4
(1) (1) (4) (1) Flanges EN 1092-2 ENPN 25
1092-2 PN 25
fM
Holes
G 3/8 DN DE DK DG
N. Ø
(2)
G 3/8 G 3/8 50 165 125 99 4 19
(2) (3)
DN
DN
h1
4.93.210/2
25
a
G 3/8 (4)
(2) G 1/4
(1)
(1) Filling and air vent
215
250
200
(5) MXV EI (H) : + 3 kg AS Ø15
G 3/8
(6) Net weight (3)
13 15 130
(7) Pressure transducer
130 40 170
(4) Standard position of I-MAT.
(for other positions rotate motor through 90° or 180°) 196 m4
Pump Motor mm
(5)
(6)
kW HP DN a h1 f M fM P AD AG AS m4 kg
MXV EI 50-1501 1,1 1,5 M80 V1 50 300 90 438 255 693 200 286 190 105 313 47,1
MXV EI 50-1502 1,5 2 M90 V1 50 300 90 438 255 693 200 286 190 105 313 47,6
MXV EI 50-1503/A 2,2 3 M90 V1 50 300 90 486 311 797 200 294 210 118 361 62,5
MXV EI 50-1504 3 4 M100 V1 50 300 90 534 311 845 250 294 210 118 409 64,9
MXV EI 50-1505 4 5,5 M112 V1 50 300 90 582 311 893 250 294 210 118 457 69,1
MXV EI 50-1506 5,5 7,5 M132 V1 50 300 90 693 339 1032 300 321 210 118 505 94,6
MXV EI 50-1507 5,5 7,5 M132 V1 50 300 90 741 339 1080 300 321 210 118 553 96,0
MXV EI 50-1508/A 5,5 7,5 M132 V1 50 300 90 789 339 1128 300 368 281 153 601 97,5
MXV EI 50-1509 7,5 10 M132 V1 50 300 90 837 339 1176 300 368 281 153 649 111,1
MXV EI 50-1510 7,5 10 M132 V1 50 300 90 885 339 1224 300 368 281 153 697 112,6
MXV EI 50-1511 9,2 12,5 M160 V1 50 300 90 963 413 1376 350 393 281 153 745 145
MXV EI 50-1512 9,2 12,5 M160 V1 50 300 90 1011 413 1424 350 393 281 153 793 146,5
MXV EI 50-1513 11 15 M160 V1 50 300 90 1059 459 1518 350 393 281 153 841 151,5
MXV EI 50-1514 11 15 M160 V1 50 300 90 1107 459 1566 350 393 281 153 889 153,0
MXV EI 50-1515 11 15 M160 V1 50 300 90 1155 459 1614 350 393 281 153 937 154,5
MXV EI 50-1516 15 20 M160 V1 50 300 90 1203 484 1687 350 471 350 190 985 202,1
MXV EI 50-1517 15 20 M160 V1 50 300 90 1251 484 1735 350 471 350 190 1033 203,6
MXV EI 50-2001 1,1 1,5 M80 V1 50 300 90 438 255 693 200 286 190 105 313 47,1
MXV EI 50-2002 2,2 3 M90 V1 50 300 90 438 295 733 200 286 210 118 313 53,0
MXV EI 50-2003 3 4 M100 V1 50 300 90 486 311 797 250 294 210 118 361 63,4
MXV EI 50-2004 4 5,5 M112 V1 50 300 90 534 311 845 250 294 210 118 409 67,6
MXV EI 50-2005 5,5 7,5 M132 V1 50 300 90 645 339 984 300 321 210 118 457 93,1
MXV EI 50-2006 7,5 10 M132 V1 50 300 90 693 339 1032 300 368 281 153 505 106,8
MXV EI 50-2007 7,5 10 M132 V1 50 300 90 741 339 1080 300 368 281 153 553 108,2
MXV EI 50-2008 9,2 12,5 M160 V1 50 300 90 819 413 1232 350 393 281 153 601 140,7
MXV EI 50-2009 9,2 12,5 M160 V1 50 300 90 867 413 1280 350 393 281 153 649 142,1
MXV EI 50-2010 11 15 M160 V1 50 300 90 915 459 1374 350 393 281 153 697 147,2
MXV EI 50-2011 11 15 M160 V1 50 300 90 963 459 1422 350 393 281 153 745 148,6
MXV EI 50-2012 15 20 M160 V1 50 300 90 1011 484 1495 350 471 350 190 793 196,3
MXV EI 50-2013 15 20 M160 V1 50 300 90 1059 484 1543 350 471 350 190 841 197,7
MXV EI 50-2014 15 20 M160 V1 50 300 90 1107 484 1591 350 471 350 190 889 199,2
MXV EI 50-2015 15 20 M160 V1 50 300 90 1155 484 1639 350 471 350 190 937 200,7
MXV EI 50-2016 18,5 25 M160 V1 50 300 90 1203 538 1741 350 491 350 190 985 222,1
168
50-15
MXV EI 50-20 Vertical Multi-Stage In-Line Pumps
M Oval Counterflanges
34
P
DN 50
G2
G 1/4 G 1/4 G 1/4 (7)
(1) (1) (4) (1)
fM
Oval Flanges
N. 2 M 12
f
G 3/8 G 3/8
(2) (3)
DN
DN
DN 50
100
130
h1
4.93.210/2
25
a
(4)
G 1/4
(1)
(1) Filling and air vent
215
250
200
(5) MXV EI (H) : + 3 kg AS Ø15
G 3/8
(6) Net weight (3)
13 15 130
(7) Pressure transducer
130 40 170
(4) Standard position of I-MAT.
(for other positions rotate motor through 90° or 180°) 196 m4
Pump Motor mm
(5)
(6)
kW HP DN a h1 f M fM P AD AG AS m4 kg
MXV EI 50-1501 O 1,1 1,5 M80 V1 50 200 90 438 255 693 200 286 190 105 313 44,3
MXV EI 50-1502 O 1,5 2 M90 V1 50 200 90 438 255 693 200 286 190 105 313 44,8
MXV EI 50-1503/A O 2,2 3 M90 V1 50 200 90 486 311 797 200 294 210 118 361 59,7
MXV EI 50-1504 O 3 4 M100 V1 50 200 90 534 311 845 250 294 210 118 409 62,1
MXV EI 50-1505 O 4 5,5 M112 V1 50 200 90 582 311 893 250 294 210 118 457 66,3
MXV EI 50-1506 O 5,5 7,5 M132 V1 50 200 90 693 339 1032 300 321 210 118 505 91,8
MXV EI 50-1507 O 5,5 7,5 M132 V1 50 200 90 741 339 1080 300 321 210 118 553 93,2
MXV EI 50-1508/A O 5,5 7,5 M132 V1 50 200 90 789 339 1128 300 368 281 153 601 95,2
MXV EI 50-1509 O 7,5 10 M132 V1 50 200 90 837 339 1176 300 368 281 153 649 108,3
MXV EI 50-1510 O 7,5 10 M132 V1 50 200 90 885 339 1224 300 368 281 153 697 109,8
MXV EI 50-2001 O 1,1 1,5 M80 V1 50 200 90 438 255 693 200 286 190 105 313 44,3
MXV EI 50-2002 O 2,2 3 M90 V1 50 200 90 438 295 733 200 286 210 118 313 50,2
MXV EI 50-2003 O 3 4 M100 V1 50 200 90 486 311 797 250 294 210 118 361 60,7
MXV EI 50-2004 O 4 5,5 M112 V1 50 200 90 534 311 845 250 294 210 118 409 64,8
MXV EI 50-2005 O 5,5 7,5 M132 V1 50 200 90 645 339 984 300 321 210 118 457 90,3
MXV EI 50-2006 O 7,5 10 M132 V1 50 200 90 693 339 1032 300 368 281 153 505 104,0
MXV EI 50-2007 O 7,5 10 M132 V1 50 200 90 741 339 1080 300 368 281 153 553 105,4
MXV EI 50-2008 O 9,2 12,5 M160 V1 50 200 90 819 413 1232 350 393 281 153 601 137,9
MXV EI 50-2009 O 9,2 12,5 M160 V1 50 200 90 867 413 1280 350 393 281 153 649 139,3
MXV EI 50-2010 O 11 15 M160 V1 50 200 90 915 459 1374 350 393 281 153 697 144,4
169
65-32
MXV EI 80-48 Vertical Multi-Stage In-Line Pumps
DN 65-80
M DN
DG
P DK
DE
Flanges in accordance
(4) G 3/8 EN 1092-2 PN 25 EN- 40
1092-2 PN 25 - 40
(1)
fM Holes
DN DE DK DG
N. Ø
f G 1/8 (7)
(2) 65 185 145 118 8 19
G 3/8 G 3/8 DN DN 80 200 160 132 8 19
(3) (3)
h1
4.93.210/2
35
a
(4)
AG
200
AS Ø14
G 3/8 (3)
14 15 220
220 43 260
Pump mm MXV EI
Motor
(5)
kW HP DN a h1 f M fM P AD AG AS m4 kg (6)
MXV EI 65-3202/D 4 5,5 M112 V1 65 320 105 407 311 718 250 294 210 118 334 80,8
MXV EI 65-3203/C 5,5 7,5 M132 V1 65 320 105 473 339 812 300 321 210 118 380 101,3
MXV EI 65-3204/C 7,5 10 M132 V1 65 320 105 519 339 858 300 368 281 153 426 115,5
MXV EI 65-3205/D 11 15 M160 V1 65 320 105 595 459 1054 350 393 281 153 472 152,8
MXV EI 65-3206/D 11 15 M160 V1 65 320 105 641 459 1100 350 393 281 153 518 154,8
MXV EI 65-3207/D 15 20 M160 V1 65 320 105 687 484 1171 350 471 350 190 564 203
MXV EI 65-3208/D 15 20 M160 V1 65 320 105 733 484 1217 350 471 350 190 610 205
MXV EI 65-3209/E 18,5 25 M160 V1 65 320 105 779 538 1317 350 491 350 190 656 227
MXV EI 65-3210/E 18,5 25 M160 V1 65 320 105 825 538 1363 350 491 350 190 702 229
MXV EI 65-3212/D 22 30 M180 V1 65 320 105 917 538 1455 350 491 350 190 794 239
MXV EI 80-4801/D 4 5,5 M112 V1 80 320 105 411 311 722 250 294 210 118 338 80,8
MXV EI 80-4802/C 5,5 7,5 M132 V1 80 320 105 466 339 805 300 321 210 118 373 101,3
MXV EI 80-4803/C 7,5 10 M132 V1 80 320 105 527 339 866 300 368 281 153 434 116,5
MXV EI 80-4804/D 11 15 M160 V1 80 320 105 618 459 1077 350 393 281 153 495 154,8
MXV EI 80-4805/D 15 20 M160 V1 80 320 105 680 484 1164 350 471 350 190 557 203
MXV EI 80-4806/D 15 20 M160 V1 80 320 105 741 484 1225 350 471 350 190 618 206
MXV EI 80-4807/E 18,5 25 M160 V1 80 320 105 802 538 1340 350 491 350 190 679 229
MXV EI 80-4808/D 22 30 M180 V1 80 320 105 864 538 1402 350 491 350 190 741 238
170
100-65
MXV EI 100-90 Vertical Multi-Stage In-Line Pumps
AD
M
P
(3)
(1)(5)
fM
(1)
f
Flanges in accordance
EN 1092-2 EN 1092-2
DN DN
Holes
DN DN PN DE DK
N. Ø
DK
140
n1
(2) Draining
AG
(3) Standard position of I-MAT
AS (for other positions rotate motor through 90° or 180°)
(4) Net weight
m2 (5) Pressure transducer
N. 4 x Ø15 m1
Pump Motor mm
MXV EI
kW HP PN Size a f n1 n2 m1 m2 M fm P AD AG AS kg (4)
MXV EI 100-6501 5,5 7,5 16 M132 V1 365 737 316 265 240 190 339 1076 300 321 210 118 131,3
MXV EI 100-6502-2R 7,5 10 16 M132 V1 365 829 316 265 240 190 339 1168 300 368 281 153 142,6
MXV EI 100-6502 11 15 16 M160 V1 365 849 316 265 240 190 459 1308 350 393 281 153 179,3
MXV EI 100-6503-2R 15 20 16 M160 V1 365 941 316 265 240 190 484 1425 350 471 350 190 230
MXV EI 100-6503/A 18,5 25 16 M160 V1 365 941 316 265 240 190 538 1479 350 491 350 190 250
MXV EI 100-6504-2R/A 18,5 25 16 M160 V1 365 1033 316 265 240 190 538 1571 350 4-1 350 190 254,5
MXV EI 100-6504 22 30 16 M180 V1 365 1033 316 265 240 190 538 1571 350 491 350 190 262
MXV EI 100-9001-1R 5,5 7,5 16 M132 V1 380 737 341 280 260 199 339 1076 300 321 210 118 132,8
MXV EI 100-9001 7,5 10 16 M132 V1 380 737 341 280 260 199 339 1076 300 368 281 153 139,6
MXV EI 100-9002-2R 11 15 16 M160 V1 380 849 341 280 260 199 459 1308 350 393 281 153 179,8
MXV EI 100-9002 15 20 16 M160 V1 380 849 341 280 260 199 484 1333 350 471 350 190 226
MXV EI 100-9003-2R/A 18,5 25 16 M160 V1 380 941 341 280 260 199 538 1479 350 491 350 190 250
MXV EI 100-9003 22 30 16 M180 V1 380 941 341 280 260 199 538 1479 350 491 350 190 257
171
MXV Vertical Multi-Stage In-Line Pumps
Features
MXV 25,32,40,50
Removable mechanical Seal
Easy removal of the mechanical seal
without dismantling the motor (for MXV
25,32,40,50 and MXV 100 with motors
exceeding 4 KW).
Extra Safety
Single-piece coupling guard to be removed only by means of a tool, positioned
around the lantern bracket, thus avoiding accidental pushing and rubbing
against the coupling. MXV 25, 32, 40, 50
Low-Noise Operation
The water filled shroud around the stages and thick external walls, work
together for low-noise operation.
Low-noise standard motor.
3.93.112
MXV 65, 80
172
MXVL AISI 316L Vertical Multi-Stage In-Line Pumps
Construction
Vertical multi-stage pumps with suction and delivery connections of
the same diameter and arranged along the same axis (in-line).
Corrosion-resistant bearing sleeves lubricated by the pumped liquid.
Removal of the mechanical seal without dismantling the motor
(for MXVL 25, 32, 40, 50, 100 with motors exceeding 4 KW).
A pump with thrust bearing and sleeve coupling for use of any
standard motor with IM V1 construction.
Version with frequency converter (on request)
Applications
For water supply systems.
For clean non-explosive liquids, without solid, filamentary or
abrasive matter (with adaptation of sealing materials on request).
A universal pump for civil and industrial use, for pressure-boosting
systems, fire-extinguishing systems, high-pressure washing
plants, irrigation, agricultural uses and sport installations.
Operating conditions
Temperature of liquid: from -15 °C to +110 °C (up to +120 °C
for MXVL 50).
Operating environment temperature: up to 40 °C.
Maximum permissible pressure in pump casing: 25 bar.
(16 bar for pumps with oval flanges).
Motor
Standard-type: 2-pole induction motor, 50 Hz (n ≈ 2900 rpm).
Construction IM V1 (EN 60034-7).
Motor suitable for operation with frequency converter.
Classification scheme IE3 for three-phase motors.
Insulation class F.
Protection IP 55.
three-phase with rated voltage: up to 3 kW 230/400 V;
The electropumps MXVL series comply with the European Regulation no. 547/2012. from 4 kW 400/690 V.
173
MXVL AISI 316L Vertical Multi-Stage In-Line Pumps
Coverage chart
4 5 Imp. g.p.m. 10 20 30 40 50 100 200 300 400 500
250
800
MXV
MXVL
n≈ 2900 1/min
700
200
50-20 H
H
ft
m
50-15
150 500
400
100-65
100
300
100
0 0
1 m3 /h 2 3 4 5 6 7 8 9 10 16 20 32 40 48 60 70 80 90100 150
Q l/min 30 40 50 100 150 200 300 400 500 1000 1500 2000
72.936/1
174
03/2021
SPA
Compact SPA
Self-Draining Whirlpool Pumps
Construction
Self-draining, single-impeller pumps, with motor insulated
from pumped water, constructed with high quality, corrosion-
proof plastic materials, with stainless steel diffuser.
Compact design (158 mm wide).
PVC pipe connections:
Ports for cementing joint, with external thread for union coupling.
Applications
For spas, hydromassage bathtubs and whirlpool baths.
Operating conditions
Water temperature up to 60 °C.
Room temperature up to 40 °C.
Maximum permissible pressure in the pump casing: 2,5 bar.
Continuous duty.
Motor
2-pole induction motor, 50 Hz (n ≈ 2800 rpm).
SPA: three-phase 230/400 V ± 10%.
SPAM: single-phase 230 V ± 10%, with thermal protector.
Capacitor inside the terminal box.
Insulation class F.
Protection IP X5.
Materials Classification scheme IE3 for three-phase motors from 0,75 kW.
Component Material Constructed in accordance with: EN 60034-1; EN 60034-30-1.
EN 60335-1, EN 60335-2-60.
Pump casing ABS (Acrylonitrile-Butadiene-Styrene)
Union coupling
Diffuser cover Glass reinforced Special features on request
Impeller thermoplastic: PPO-GF30, NORYL*
- Other voltages.
Diffuser-wall Cr-Ni-Mo stainless steel - Frequency 60 Hz (as per 60 Hz data sheet).
with wear-ring 1.4401 EN 10088 (AISI 316)
Mechanical seal Ceramic alumina, Carbon, FPM
* Trademark of General Electric
0 U.S. g.p.m. 20 40 60 80
20
60
H
m ft
40
10
41
20
SPA 11 21 31
0 0
0 m 3/h 6 12 18
0 Q l/min 100 200 300
72.917.2
175
SPA
Compact SPA
Self-Draining Whirlpool Pumps
mm kg
Type
TIPO
fM H m1 m2 w1 w SPA SPAM
146
SPA 11 339 176 34 26 122 97 6,7 6,8
180
H
SPA 21/A 371 191 39 31 136 102 8 9
10
SPA 31/B 371 191 39 31 136 102 9,8 10
34
3.93.070
m1 9
w 8 112
m2 w1 146
SPA 41/A
419 158
70
Ø 50
Cemented joint.
25
146
208
180
10
34
ISO 228
G 2 1/4
Ø 50
4.93.225/1
Features
Diffuser with peripheral-longitudinal flow,
of stainless steel for extra reliability.
4.93.035
176
03/2021
MPC
Compact Pool
Self-Priming Swimming Pool Pumps
Construction
Self-priming swimming pool pumps with built-in strainer and
motor insulated from pumped water.
The pump is made with high quality plastic materials, corrosion
and sand erosion resistant.
With stainless steel diffuser.
Base-plate kit.
Applications
- For water circulation in swimming pool filtration systems.
- For clean or slightly dirty water with solids in suspension.
Operating conditions
Water temperature up to 60 °C.
Ambient temperature up to 40 °C.
Maximum permissible pressure in the pump casing 2,5 bar.
Continuous duty.
Motor
2-pole induction motor, 50 Hz (n ≈ 2800 rpm).
MPC: three-phase 230/400 V ± 10%.
MPCM: single-phase 230 V ± 10%, with thermal protector.
Capacitor inside the terminal box.
Insulation class F.
Protection IP X4.
Classification scheme IE3 for three-phase motors from 0,75 kW.
Constructed in accordance with: EN 60034-1; EN 60034-30-1.
EN 60335-1, EN 60335-2-41.
Materiali
Component Material Special features on request
Pump casing Glass reinforced - Other voltages.
Diffuser cover thermoplastic - Frequency 60 Hz (as per 60 Hz data sheet).
Impeller PPO-GF30, NORYL
Strainer cover Transparent polycarbonate, LEXAN
Strainer basket Polypropylene
Certification marks for MPCM, up to 1,5 kW:
Diffuser funnel
Cr-Ni-Mo steel AISI 316
and wear-ring
Mechanical seal Ceramic alumina, Carbon, FPM SUD geprüfte
Sicherheit
60
H ft
m
40
10
MPC 71
41 20
61 MPCM 71
31
21 51
11
0 0
0 m 3/h 6 12 18 24 30 36 42
Q
0 l/min 100 200 300 400 500 600 700
72.859.2
177
MPC
Compact Pool
Self-Priming Swimming Pool Pumps
Self-Priming Capability with the pump located above the water level
15 15 15 15
L=5m 4 3 2 1 L=5m 4 3 2 1 L=7m L=7m
6
6
5
MPC 11 0 MPC 21 MPC 31 MPC 41 5
4
3 4
10 10 10 2 10
0
3
t t t 1 t
min min min min 2
0 1
5 5 5 5
0
(1)
(1)
72.859/1
(1) (1)
0 0 0 0
0 1 2 3 4 0 1 2 3 4 0 1 2 3 4 0 1 2 3 4
Hs m Hs m Hs m Hs m
15 15 15
L=7m 6 5 L=7m
L =7m 6
4
MPC 51 6 MPC 61 MPC 71
three-phase only 5
3
5
4
10 10 2 10
4
3
t 3 t 1 t
min min min 2
2 0
1
5 1 5 5
0
0
(1)
72.906
(1)
(1)
0 0 0
0 1 2 3 4 0 1 2 3 4 0 1 2 3 4
Hs m Hs m Hs m
L
(1) Application limit for automatic self-repriming at each start-up, without L
check valve.
L (m) Horizontal length of suction pipe above the water level. G2
Hs (m) Suction lift. Hs DN 50
t (min) Self-priming time.
3.93.025
178
MPC
Compact Pool
Self-Priming Swimming Pool Pumps
mm kg
50
TIPO
TYPE
G2
fM w MPC MPCM
323
293 MPC 21/A - MPCM 21/A 536 100 10,2 11,3
243
MPC 31/B - MPCM 31/A 536 100 12,0 12,2
3.93.028
7
(2) (2) w 9
(1)
197
128,5 123 215
410
584
235 215
ISO 228
323
293
243
80
G2
MPCM 51 18,9 kg
323
MPC 51/A
323
17,4 kg
243
MPCM 61 20,7 kg
MPC 61/A 19,6 kg
21
30
188 260 72 220
520 250
179
MPC
Compact Pool
Self-Priming Swimming Pool Pumps
Features
4.93.035
3.93.102
Stainless steel AISI 316 wear-ring diffuser-funnel, Mechanical seal without contact with the shaft,
for extra reliability for extra safety
180
03/2021
Construction
Close-coupled self-priming centrifugal pumps with built-in
strainer.
Inner basket with Ø 3 mm holes.
NMP: version with pump casing and lantern bracket in cast iron,
with cataphoresis coating.
B-NMP: version with pump casing and lanter bracket in bronze
(the pumps are supplied fully painted).
Applications
For water circulation in swimming pool filtration systems.
For clean or slightly dirty water with solids in suspension.
Operating conditions
Liquid temperature up to 60° C.
Ambient temperature up to 40° C.
Total suction lift up to 7 m.
Maximum permissible working pressure up to 6 bar.
Continuous duty.
Motor
2-pole induction motor, 50 Hz (n ≈ 2900 rpm).
NMP: three-phase 230/400 V ± 10% up to 3 kW;
400/690 V ± 10% from 4 to 7,5 kW;
NMPM: single-phase 230 V ± 10%, with thermal protector.
Materials Insulation class F.
Components NMP B-NMP Protection IP 54.
Pump casing Cast iron Bronze Classification scheme IE3 for three-phase motors from 0,75 kW.
Lantern bracket GJL 200 EN 1561 G-Cu Sn 10 EN 1982 Constructed in accordance with: EN 60034-1; EN 60034-30-1.
Impeller Cast iron Bronze EN 60335-1, EN 60335-2-41.
GJL 200 EN 1561 G-Cu Sn 10 EN 1982
Brass P- Cu Zn 40 Pb 2 UNI 5705 for NMP 32/12
Shaft Chrome-nickel steel Cr-Ni-Mo steel
1.4305 EN 10088 (AISI 303) 1.4401 EN 10088 (AISI 316) Special features on request
Strainer cover Cast iron Bronze - Other voltages.
GJL 200 EN 1561 G-Cu Sn 10 EN 1982 - Frequency 60 Hz (as per 60 Hz data sheet).
Strainer Chrome-nickel steel 1.4301 EN 10088 (AISI 304) - Protection IP 55.
Mechanical seal Carbon - Ceramic - FPM - Special mechanical seal
- Higher liquid or ambient temperatures.
H 80
m
20
60
NMP 65/12
H
ft
10
20
0 0
5 m3/h 10 20 30 40 50 100 120 140
Q
100 l/min 200 300 400 500 1000 1500 2000
72.891.C
181
NMP Self-Priming Centrifugal Pumps
with built-in strainer
P1 Maximum power input. B-NMP = Bronze construction. * Maximum suction lift 2-3 m.
P2 Rated motor power output. H Total head in m. Tolerances according to UNI EN ISO 9906:2012
fM
a l1 l2
DN2
h2
DN1
h5
h1 H
g1
4.93.067
m2 s n3 b
m1 n2 TYPE NMP B-NMP
TIPO
w n1 kg kg
(B)NMP 32/12FE 30 32
DN1 DN2 mm (B) NMP 32/12DE 30 32
TIPO
TYPE (B) NMP 32/12A/A 31 33
ISO 228 a fM h1 h2 H h5 m1 m2 n1 n2 n3 b s l1 l2 w g1 (B) NMP 32/12S/A 33 35
182
NMP Self-Priming Centrifugal Pumps
with built-in strainer
Hm
50 H Ø 100
H ft
H ft
15 10 52
F Ø 103 30
40
20
10 66 5
30
η 67%
10
20
5 0 0
0 3 5 10 15 20 25 3
0
Q m /h Q m /h 10 20 30 40 50 60 70
0 l/min 100 150 200 250 300 350 400 0 l/min 200 400 600 800 1000
0 l/s 1 2 3 4 5 6 0 l/s 2 4 6 8 10 12 14 16 18
1.6 3 4
S 2.0 D
1.2 F 3
A 1.5 2
P kW
P kW
P HP
P HP
0.8 D G
1.0 2
F H
1
0.4 0.5 1
0 0 0 0
8 25 8 25
NPSH m
NPSH m
6 20 6 20
NPSH ft
NPSH ft
15 15
4 4
10 10
2 2
5 5
0 72.063
0 0 72.061
0
0 Q m3/h 5 10 15 20 25 0 Q m3/h 10 20 30 40 50 60 70
40
10 30
20
10
0 0
0 m3/h 20 30 40 50 60 70 80 90 100 110 120 130
Q l/min
0 500 1000 1500 2000
8
A 10
6 8
C
P kW
4 6
E
P HP
4
2
2
0 0
80
60
A
η (%)
40 C
E
20
0
10
A 30
E
NPSH m
8
20
NPSH ft
6
4
10
2
0 0
0 Q m3/h 20 30 40 50 60 70 80 90 100 110 120 130
183
NMP Self-Priming Centrifugal Pumps
with built-in strainer
Features
3.94.082
Flexible
The option to choose between cast iron and bronze materias for the hydraulic
parts in contact with the pumped liquid allows NMP seies pumps to be selec-
ted for use with different types of liquids.
Exclusive design
An innovative, patented guard prevents contact with rotating parts, proving pro-
tection to the end user whilst allowing for inspection of the mechanical seal.
Reliable
The bearing and shaft are designed to ensure the reduction of the stress, pro-
viding high reliability under all operating conditions.
184
03/2021
Construction
Pre-filters with removable basket, constructed in stainless steel.
Loose ring flange connections.
Clamp type closing with lever and double adjustment clamp.
Inner basket with Ø 6 mm holes.
Applications
For water circulation pump in filtration plants in swimming
pools.
To prevent foreign bodies from entering the pump and the
plant.
Operating conditions
Max working pressure: 3 bar.
Max flow: 180 m3/h for PF 100.
240 m3/h for PF 125.
300 m3/h for PF 150.
Materials
Components Materials
Pre-filter body PF 100-304
PF 125-304 Stainless steel AISI 304
PF 150-304
Pre-filter body PF 100-316
PF 125-316 Stainless steel AISI 316
PF 150-316
Strainer basket Stainless steel AISI 316
4
H DN
H DN
m
h2 h1
3
4.93.206.1
L (2) B
2 FlangesUNI
Flange UNI6089
6089PN
PN10
10
mm
Type
Tipo
kg
DN H h1 h2 L D B
0
0
Q m3 /h 50 100 150 200 250 300 1 Relief valve 2 Draining plug
185
PF Pre-filters in stainless steel
Examples of installations
186
03/2021
Construction
Close-coupled centrifugal pumps with open impeller.
The built-in backflow preventer avoids reverse siphoning when the
pump is stopped and assures automatic re-priming at the next start.
The pump re-primes itself even if partially filled with liquid and
with completely empty suction pipe.
A: version with pump casing and lantern bracket in cast iron.
B-A: version with pump casing and lantern bracket in bronze
(the pumps are supplied fully painted).
Applications
For clean or slightly dirty water, also with solids up to 10 mm
grain size for A 40, A 50 and 15 mm for A 65, A 80.
For draining a basin or a sump.
For irrigation. For civil and industrial applications.
Operating conditions
Liquid temperature from -10 °C to +90 °C.
Room temperature up to 40 °C.
Maximum permissible working pressure up to 6 bar (10 bar for
A 80-170).
Continuous duty.
Motor
2-pole induction motor, 50 Hz (n ≈ 2900 rpm).
A three-phase 230/400 V ± 10% up to 3 kW;
400/690 V ± 10% from 4 to 7,5 kW;
AM: single-phase 230 V ± 10%, with thermal protector.
Capacitor inside the terminal box.
Materials Insulation class F.
Components A B-A Protection IP 54.
Classification scheme IE3 for three-phase motors from 0,75 kW.
Pump casing Constructed in accordance with: EN 60034-1; EN 60034-30-1.
Suction flange
Inspection cover Cast iron Bronze EN 60335-1, EN 60335-2-41.
(for A 65, A 80) GJL 200 EN 1561 G-Cu Sn 10 EN 1982
Lantern bracket Special features on request
Impeller Other voltages.
Shaft Chrome-nickel steel Frequency 60 Hz (as per 60 Hz data sheet).
1.4305 EN 10088 (AISI 303) Cr-Ni-Mo steel Protection IP 55.
Chrome steel 1.4104 EN 10088 1.4401 EN 10088 (AISI 316) Special mechanical seal.
(AISI 430) for A 40/110, A 65-150A,B Higher or lower liquid or ambient temperatures.
Mechanical seal Carbon - Ceramic - NBR Construction with bearing bracket.
120
30 100
H
H ft
m A 80-170 80
20
A 65-150 60
40
10 A 50-125
A 40-110 20
0 0
0 m 3/h 10 20 30 40 50 60 70
0 Q l/min 200 300 400 500 600 700 800 900 1000 1100
72.855
187
A Self-Priming Centrifugal Pumps
with open impeller
3~ 230 V 400 V 1~ 230 V P1 P2 m3/h 3,6 4,8 6 7,5 8,4 9,6 10,8 12 15 18
Q
A A A kW kW HP l/min 60 80 100 125 140 160 180 200 250 300
A 40-110B/A AM 40-110B/A
B-A 40-110B/A 2,8 1,6 B-AM 40-110B/A 4,5 0,85 0,55 0,75 12,9 12,4 11,8 11 10,4 9,8 9 8,3 6 3,4
A 40-110A/B AM 40-110A/A
Hm
B-A 40-110A/B 3,7 2,2 B-AM 40-110A/A 6 1,1 0,75 1 15,4 14,9 14,2 13,3 12,9 12,1 11,3 10,5 8,4 5,6
P1 Maximum power input. P2 Rated motor power output. H Total head in m. B-A, B-AM = Bronze construction. Tolerances according to UNI EN ISO 9906:2012
188
A Self-Priming Centrifugal Pumps
with open impeller
Self-priming capability
with DN
Tubo 40 mmDN
aspirante suction
40 mm pipe with DN
Tubo 50 mmDN
aspirante suction
50 mm pipe with DN
Tubo 65 mmDN
aspirante suction
65 mm pipe
20 20 15
A 40-110 A 50-125 t
A 65-150
L =1m
min
L= 1 m L= 1 m
t t C
min min
10
B C
A
10 10 B
B
5
A A
0 0 0
0 2 4 6 0 2 4 6 0 2 4 6
Hs m Hs m Hs m
Tubo aspirante
with DN 80 mmDN 80 mm
suction pipe
10
A 80-170
t
L= 1 m
min
5
A
≥ 0,5 m
L
0
0 2 4 6
Hs m
Hs
3.93.021.2
HsHs(m)(m)
Suction lift.di aspirazione.
Altezza
L L(m)(m)Horizontal
Lunghezza length
del of suction
tubo pipe orizzontale
aspirante above the water
sopralevel.
il livello dell'acqua.
t t(min) Self-priming time.
(min) Tempo di autoadescamento.
Risultati di collaudo con acqua fredda
189
A Self-Priming Centrifugal Pumps
with open impeller
C Ø 107 58
H ft
10
Hm
56
30
H ft
54 40
8 50
10
6 20 30
4 20
10
5
2
10
0 0
0 3 5 10 15 20
Q m /h 0 0
0 l/min 100 200 300 0 3
1,0 Q m /h 5 10 15 20 25 30 35
0 l/min 100 200 300 400 500
0,8 A 1,0
P kW
l/s 1
P HP
0,6 B 0 2 3 4 5 6 7 8 9
0,4 2
0,5 2.5
0,2 A
2.0
0 0
P kW
P HP
60
B 1.5
1
C
1.0
η (%)
40 A
0.5
20 B
0 0
0
8 25
8
NPSH m
NPSH m
6 6 20
NPSH ft
20
NPSH ft
15
4 4
10 10
2 2
5
0 0 0 0
0 3 5 10 15 20 72.370
Q m /h 0 Q m3/h 5 10 15 20 25 30 35
0 U.S. g.p.m. 50 100 150 200 250 0 U.S. g.p.m.50 100 150 200 250 300
40
A Ø 150 100 A Ø 165 120
30 50
55 57
A 65-150 A 80-170
59 100
30 B Ø 153
80
B Ø 133 η 61%
59 80
20 57
C Ø 126 55 20
Hm
Hm
60
H ft
50 60
H ft
40 40
10 10
20
20
0 0
0
Q m /h 10 20 30 40 50 60 70
3
0 0
0 3 10 20 30 40 50 60 0 l/min 200 400 600 800 1000
Q m /h
0 l/min 200 300 400 500 600 700 800 900 1000 7 A 10
0 l/s 2 4 6 8 10 12 14 16 8
P HP
B
P kW
5
5 6
A 6 3 4
4
5 2
1
P kW
3 4
P HP
B
60
2 C 3 A
η (%)
2 40 B
1
1
20
0 0
10 0
30 10
30
NPSH m
NPSH m
8
8
NPSH ft
NPSH ft
6 20 6 20
4 4
10 10
2 2
0 0 0 0
0
Q m /h 10 20 30 40 50 60 70
3
0 Q m3/h 20 40 72.371 60
190
A Self-Priming Centrifugal Pumps
with open impeller
275
208
B-A 40-110A/B 23,3
206
B-AM 40-110A/A 23,5
B-A 40-110B/A 21,6
B-AM 40-110B/A 22,5
70 16 50
100 140
199 190
490
147 96 102
kg
G2
ISO 228 A 50-125A/A 29,9
AM 50-125AE 31
A 50-125B/A 28
AM 50-125BE 29,1
A 50-125CE 26,9
ISO 228
295
G2
AM 50-125CE 27,8
231
223
B-A 50-125A/A 33,6
14 B-AM 50-125AE 33,6
4.93.103 B-A 50-125B/A 31
70 16 30 50 B-AM 50-125BE 32,6
100 140 B-A 50-125CE 29,6
263 190 B-AM 50-125CE 30,6
fM
172 115 121
G 2 1/2
ISO 228
mm
TIPO
TYPE kg
fM H w
660
202
G3 132 140
ISO 228
kg
A 80-170A/A 85,8
A 80-170B/A 80,3
ISO 228
G3
427
342
317
B-A 80-170A/A 95,6
17
B-A 80-170B/A 90,1
110 18 47 60
145 220
311 280
191
A Self-Priming Centrifugal Pumps
with open impeller
Features
1.94.032
Flexible
The option to choose between cast iron and bronze materias for the hydraulic
parts in contact with the pumped liquid allows A series pumps to be selected for
use with different types of liquids.
Solid parts
The open impeller allows for the passage of suspended solids in pumped liquid.
Exclusive design
An innovative, patented guard prevents contact with rotating parts, proving pro-
tection to the end user whilst allowing for inspection of the mechanical seal.
Reliable
The bearing and shaft are designed to ensure the reduction of the stress, provi-
ding high reliability under all operating conditions.
192
03/2021
C Centrifugal Pumps
with open impeller
Construction
Close-coupled centrifugal pumps with open impeller.
Free-flow impeller (vortex or recessed impeller) for type C 16/1E.
Applications
For moderately dirty liquids or emulsions.
For industry and agriculture.
Operating conditions
Liquid temperature from -10 °C to +90 °C.
Ambient temperature up to 40 °C.
Total suction lift up to 8 m.
Maximum permissible working pressure: 6 bar.
Maximum size of solids: 4 mm.
Continuous duty.
Motor
2-pole induction motor, 50 Hz (n ≈ 2900 rpm).
C: three-phase 230/400 V ± 10%.
CM: single-phase 230 V ± 10%, with thermal protector.
Capacitor inside the terminal box.
Insulation class F.
Protection IP 54.
Motor suitable for operation with frequency converter from 1,1 kW.
Materials Classification scheme IE3 for three-phase motors from 0,75 kW.
Component C B-C Constructed in accordance with: EN 60034-1; EN 60034-30-1.
Pump casing Cast iron Bronze EN 60335-1, EN 60335-2-41.
GJL 200 EN 1561 G-Cu Sn 10 EN 1982
Lantern bracket Cast iron Bronze Special features on request
GJL 200 EN 1561 G-Cu Sn 10 EN 1982 - Other voltages.
Impeller Brass P- Cu Zn 40 Pb 2 UNI 5705 - Frequency 60 Hz (as per 60 Hz data sheet).
Shaft Chrome steel - Protection IP 55.
1.4104 EN 10088 (AISI 430) Cr-Ni-Mo steel - Special mechanical seal
Chrome-nickel steel 1.4401 EN 10088 - Higher or lower liquid or ambient temperatures.
1.4305 EN 10088 (AISI 303) (AISI 316) - Motor suitable for operation with frequency converter up to 0,75 kW.
for C 41 - Construction with bearing bracket.
Mechanical seal Carbon - Ceramic - NBR
U.S. g.p.m. 4 6 8 10 20 30 40 50 60 70
30
H
m 80
C 41 H
C 22 ft
20
C 22/1 C4 60
C 4/1
C 20 40
10
C 16/1 20
0 0
0.5 m3/h 1 2 3 4 5 10 15 18
Q l/min
10 20 30 40 50 100 200 300
72 892 C
193
C Centrifugal Pumps
with open impeller
194
C Centrifugal Pumps
with open impeller
266 263
34 l1 l2
33
G1 l3
G 1/2 122 ISO 228
ISO 228
ISO 228
ISO 228
G 1/2
G1
h2
75
160 160
8 63 h4 8 63
4.93.221 4.93.222
7 22
7 22
93 80 100
88 80 100
96 122 96 122
mm kg
TYPE kg TYPE kg TYPE
h2 h4 l1 l2 l3 C CM
C 16/1E 5,2 B-C 16/1E 5,6 C 20E 90 5 67 82 60 6,8 6,8
CM 16/1E 5,2 B-CM 16/1E 5,6 C 22/1E - C 22E 110 17 77 94 71 8 - 8,3 8 - 8,3
fM
a l1 l2
DN 2 l3
DN 1
h2
h4 HA h1
4_93_223
K AA
w B A
BB AB
DN1 DN2 mm kg
TIPO
TYPE
ISO 228 a fM h1 h2 H h4 BB B AB A AA K l1 l2 l3 w HA C CM B-C B-CM
– B-C 20/A G1 G1 35 303 71 90 182 - 106 90 134 112 22 7 70 84 60 105 10 - - 9,1 9,1
195
C Centrifugal Pumps
with open impeller
Hm
25 15
H ft
H ft
η 56%
28 14 11
35
4 30 13 54
η 31% 10
12
9 30
11
3 10 8
0 3 0.5 1 1.5 2 2.5 0 3 1 2 3 4 5
Q m /h Q m /h
0 l/min 10 20 30 40 0 l/min 20 30 40 50 60 70 80
0 l/s 0.1 0.2 0.3 0.4 0.5 0.6 0 l/s 0.2 0.4 0.6 0.8 1 1.2
0.1 0.3 0.4
P kW
0.1 0.3
0.2
P kW
P HP
P HP
0.05 0.2
0.1
0.1
0 0 0 0
72.126
0 Q m3/h 0.5 1 1.5 2 2.5
4
12
NPSH m
3 10
NPSH ft
8
2 6
1 4
2
0 72.121
0
0 Q m3/h 1 2 3 4 5
0 U.S. g.p.m. 10 20 30
25
80
C 22
C 22 Ø 119.5
20
35
40
44
C 22/1 70
46
C 22/1 Ø 116 47 60
46
Hm
44 50
H ft
15
40
η 49% 35
40
10
30
20
5
0 3
Q m /h 1 2 3 4 5 6 7
0 l/min 20 40 60 80 100
0.5
P HP
C 22/1
0.6
0.4
0.5
0.3 0.4
0.2 0.3
4
12
NPSH m
3 10
NPSH ft
8
2 6
1 4
2
0 0
72.123
0 Q m3/h 1 2 3 4 5 6 7
196
C Centrifugal Pumps
with open impeller
Hm
H ft
H ft
65
40 40
60
10 10
55 30 30
20 20
5 5
0 3 5 10 15 0 3 5 10 15
Q m /h Q m /h
0 l/min 50 100 150 200 250 300 0 l/min 50 100 150 200 250 300
0 l/s 1 2 3 4 5 0 l/s 1 2 3 4 5
1.0 1.0
1.2 1.2
0.8 0.8
1.0 1.0
P kW
P kW
P HP
0.4 0.6 0.4 0.6
0.4 0.4
0.2 0.2
0.2 0.2
0 0 0 0
8 25 8 25
NPSH m
NPSH m
6 20 6 20
NPSH ft
NPSH ft
15 15
4 4
10 10
2 2
5 5
0 0 0 0
72.124.1 72.124.2
0 Q m3/h 5 10 15 0 Q m3/h 5 10 15
0 U.S. g.p.m. 20 30 40 50 60 70
25
80
Ø 124 40 50
54 C 41
58
70
η 59.5%
20
58
60
Hm
H ft
15 50
40
10
0 3 5 10 15
Q m /h
0 l/min 100 200 260
0 l/s 1 2 3 4
1.2 1.6
1.0 1.4
P kW
1.2
P HP
0.8
1.0
0.6 0.8
0.6
0.4
6
NPSH m
15
NPSH ft
4
10
2
5
0 0
72.125
0 Q m3/h 5 10 15
197
C Centrifugal Pumps
with open impeller
Features
3.94.058
Flexible
The option to choose between cast iron and bronze materias for the hydraulic
parts in contact with the pumped liquid allows C series pumps to be selected for
use with different types of liquids.
Solid parts
The open impeller allows for the passage of suspended solids in pumped liquid.
Reliable
The bearing and shaft are designed to ensure the reduction of the stress, provi-
ding high reliability under all operating conditions.
198
03/2021
CT 61 Peripheral Pump
Construction
Close-coupled peripheral pump (regenerative pump) with
turbine impeller. Compact, patented construction with single-
piece motor casing and pump-side wall.
Protected against water entering the motor from outside.
CT: version with pump casing in cast iron.
B-CT: version with pump casing in bronze
(the pumps are supplied fully painted).
Applications
For clean liquids without abrasives, without suspended solids,
non-explosive, non-aggressive for the pump materials.
For increasing network pressure (follow local specifications).
For the reduced dimensions, these pumps are very well suitable
to be mounted in cooling and air-conditioning machines and
equipments, circulation.
Operating conditions
Liquid temperature up to 60 °C.
Ambient temperature up to 40 °C.
Total suction lift up to 7 m.
Maximum permissible working pressure: 6 bar.
Continuous duty.
Motor
2-pole induction motor, 50 Hz (n ≈ 2900 rpm).
CT 61: three-phase 230/400 V ± 10%.
Materials CTM 61: single-phase 230 V ± 10%, with thermal protector.
Components CT 61 B-CT 61 Capacitor inside the terminal box.
Insulation class F.
Pump casing Cast iron Bronze Protection IP 54.
GJL 200 EN 1561 G-Cu Sn 10 EN 1982 Constructed in accordance with: EN 60034-1;
Casing cover motor side Brass P- Cu Zn Pb 2 UNI 5705 EN 60335-1, EN 60335-2-41.
0 U.S. g.p.m. 2 4 6 8 10
44
140
40
CTM 61
120
CT 61
30 100
H H
m
ft
20
60
40
10
20
0 0
0 m 3/h 1 2 2.6
0
Q l/min 10 20 30 40
72.865
199
CT 61 Peripheral Pump
158
108
63
8
4.93.159/1
22 7
100 80 40.5
122 96
Features
Patented
4.94.160
200
CT 60 Peripheral Pump
Construction
Close-coupled peripheral pump (regenerative pump) with
turbine impeller.
Compact, patented construction with single-piece motor casing
and pump-side wall.
Protected against water entering the motor from outside.
Applications
For clean liquids without abrasives, without suspended solids,
non-explosive, non-aggressive for the pump materials.
For increasing network pressure (follow local specifications).
For the reduced dimensions, these pumps are very well suitable
to be mounted in cooling and air-conditioning machines and
equipments, circulation.
Operating conditions
Liquid temperature up to 60 °C.
Ambient temperature up to 40 °C.
Total suction lift up to 7 m.
Maximum permissible working pressure: 6 bar.
Continuous duty.
Motor
2-pole induction motor, 50 Hz (n ≈ 2900 rpm).
CT 60: three-phase 230/400 V ± 10%.
Materials CTM 60: single-phase 230 V ± 10%, with thermal protector.
Capacitor inside the terminal box.
Components Materials
Insulation class F.
Pump casing Cast iron GJL 200 EN 1561 Protection IP 54.
Casing cover motor side Brass P- Cu Zn Pb 2 UNI 5705 Constructed in accordance with: EN 60034-1;
EN 60335-1, EN 60335-2-41.
Impeller Brass P- Cu Zn Pb 2 UNI 5705
Shaft Chrome steel 1.4104 EN 10088 (AISI 430)
Special features on request
Mechanical seal Carbon - Ceramic - NBR - Other voltages.
- Frequency 60 Hz (as per 60 Hz data sheet).
- Special mechanical seal.
0 U.S. g.p.m. 2 4 6 8 10
44
140
40
CTM 60
120
CT 60
30 100
H H
m
ft
20
60
40
10
20
0 0
0 m 3/h 1 2 2.6
0
Q l/min 10 20 30 40
72.865_12
201
CT 60 Peripheral Pump
CT 60/A 1,9 1,1 CTM 60/A 2,5 0,55 0,33 0,45 H m 41 38,5 35,5 31 25,5 19 11 3
20 CT 60/A 4,9 kg
CTM 60/A 5 kg
G1 ISO 228 218
G1 ISO 228
75
158
63
8
4.93.528
22 7
100 80 40.5 42
122 96
Features
Patented
4.93.529
202
03/2021
T, TP Peripheral Pumps
Construction
Close-coupled peripheral pumps (regenerative pumps) with
turbine impeller.
T, TP: version with pump casing and lantern bracket in cast iron.
B-T, B-TP: version with pump casing and lantern bracket in bronze
(the pumps are supplied fully painted).
Applications
For clean liquids without abrasives, without suspended solids,
non-explosive, non-aggressive for the pump materials.
For increasing network pressure (follow local specifications).
For the reduced dimensions, these pumps are very well suitable
to be mounted in cooling and air-conditioning machines and
equipments, circulation, boiler feed.
Operating conditions
Liquid temperature from -10 °C to +90 °C.
Ambient temperature up to 40 °C.
Total suction lift up to 7 m.
Maximum permissible working pressure: 12,5 bar (16 bar for TP).
Continuous duty.
Motor
2-pole induction motor, 50 Hz (n ≈ 2900 rpm).
T, TP: three-phase 230/400 V ± 10% up to 3 kW;
400/690 V ± 10% from 4 to 7,5 kW;
TM, TPM: single-phase 230 V ± 10% with thermal protector.
Capacitor inside the terminal box.
Materials Insulation class F.
Components T, TP B-T, B-TP Protection IP 54.
Pump casing Cast iron Bronze Classification scheme IE3 for three-phase motors from 0,75 kW.
Lantern bracket GJL 200 EN 1561 G-Cu Sn 10 EN 1982 Constructed in accordance with: EN 60034-1; EN 60034-30-1.
Casing cover Cast iron Bronze EN 60335-1, EN 60335-2-41.
GJL 200 EN 1561 G-Cu Sn 10 EN 1982
Brass P- Cu Zn Pb 40 2 UNI 5705 for T 61-65-70, B-T 61-70 Special features on request
Impeller Brass P- Cu Zn 40 Pb 2 UNI 5705 - Other voltages.
Bronze G-Cu Sn 10 EN 1982 for T 125, TP 132-132R - Frequency 60 Hz (as per 60 Hz data sheet).
Shaft Cr-Ni steel AISI 303 - Protection IP 55.
T 76, Tp 80-100 Cr-Ni-Mo steel
Chrome steel AISI 430 AISI 316
- Special mechanical seal.
T 61-65-70-100-125, Tp 78-132-132R - Higher or lower liquid or ambient temperatures.
Mechanical seal Carbon - Ceramic - NBR - Construction with bearing bracket.
0 U.S. g.p.m. 5 10 15 20 25
TP 132
160
TP 100 TP 132R 500
H
m ft
T 125
120 400
T 100
TP 80 300
80
200
40
T 76 100
TP 78 T 61 T 65 T 70
0 0
0 3
m /h 1 2 3 4 5 6
0 Q l/min 20 40 60 80 100
72.853
203
T, TP Peripheral Pumps
Q
3~ 230V 400V 1~ 230V P1 P2
m3/h 0,06 0,12 0,24 0,38 0,48 0,6 0,75 1 1,2 1,5 1,89 2,4 3 3,6 4,2 4,8 5,4 6
45 h2
160 182
108 h1
8 63 10 71
4.93.227
7 22 4.93.218
7 22
80 80 100
93 90 112
96 122
106 134
T 61E: kg 6,3
DN1 DN2 mm kg
B- T 61E: kg 6,5 TYPE
TIPO
ISO 228 a1 fM h2 h1 a T B-T
T 65E: kg 7,3
B- T 65E: kg 7,5 T 70/B B-T 70/B G 1 G 1 24 278 50 121 63 12 12,4
TP 78/A B-TP 78/A G 1/2 G 1/2 22 276 24 127 56 8,2 8,8
fM
a1 a
DN2 DN1 DN2
h2
H
h1
HA HS
4.93.093
K AA
w B A
BB AB
mm kg
DN1 DN2
TIPO
TYPE
ISO 228 a1 fM HS h2 h1 H BB B AB A AA K a w HA T, TP B-TP
T 76/A – G 11/4 G 11/4 26 338 80 56 136 208 117 100 155 125 30 9 80 105 10 18,4 -
T 100/A – G 11/4 G 11/4 32 410 90 59 161 226 152 125 180 140 40 9,5 95 121 12 32,5 -
T 125/B – G 11/4 G 11/4 32 470 90 75 170 226 152 125 180 140 40 9,5 90 195 12 39,5 -
TP 80E B-TP 80E G 3/4 G 3/4 27 332 80 35 135 208 117 100 155 125 30 9 60 104 10 16,4 16,8
TP 100/B – G 3/4 G 3/4 27 387 80 38 142 208 117 100 155 125 30 9 65 113 10 23,2 -
TP 132R/A – 53,6 -
G 11/4 G 11/4 42 485 112 70 202 272 180 140 230 190 50 11,5 100 183 14
TP 132/A – 58,5 -
204
T, TP Peripheral Pumps
Hm
30
H ft
H ft
80
80
20
60 20
60
40 40
10 10
20 20
0 0 0 0
3 3
0 Q m /h 0.5 1 1.5 2 2.5 0 Q m /h 1 2 3
0 l/min 8 12 16 20 24 28 32 36 40 0 l/min 10 20 30 40 50
0 l/s 0.1 0.2 0.3 0.4 0.5 0.6 0 l/s 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8
0.4 0.6 0.8
0.5
0.3 0.4 0.6
0.4
P kW
P kW
P HP
P HP
0.3
0.2 0.4
0.2 0.2
0.1 0.2
0.1
0 0 0 0
6 8 25
18
NPSH m
NPSH m
5 6 20
NPSH ft
NPSH ft
4 13 15
4
3 10
8 2
2 5
1 72.136
3 0 72.137
0
0 Q m3/h 0.5 1 1.5 2 2.5 0 Q m3/h 1 2 3
60
Ø 71 T 70 200
Ø 76 T 76
60 200
50
40
Hm
Hm
H ft
H ft
40
30 100
100
20
20
10
0 0 0 0
0 3 1 2 3 4 0 3 1 2 3 4
Q m /h Q m /h
0 l/min 10 20 30 40 50 60 0 l/min 10 20 30 40 50 60
0 l/s 0.2 0.4 0.6 0.8 1 0 l/s 0.2 0.4 0.6 0.8 1
1.0 1.6
1.2 2
0.8
1.0 1.2
P kW
0.6
P kW
0.8
P HP
P HP
0.8 1
0.4 0.6
0.4 0.4
0.2
0.2
0 0 0 0
5 4
15
NPSH m
NPSH m
4 3 10
NPSH ft
NPSH ft
3 10
2
2 5
5 1
1
0 0 0 0
72.138 72.139
0 Q m3/h 1 2 3 4 0 Q m3/h 1 2 3 4
205
T, TP Peripheral Pumps
60 200 80
Hm
Hm
H ft
H ft
160
40 60 200
120
80
20 40
40 100
0 0 20
3 3
0
Q m /h 0.2 0.4 0.6 0.8 1 1.2 0
Q m /h 0.5 1 1.5 2
0 l/min 4 6 8 10 12 14 16 18 20 0 l/min 5 10 15 20 25 30
0 l/s 0.1 0.2 0.3 0 l/s 0.1 0.2 0.3 0.4 0.5
0.5 1.0
0.6 1.2
0.4 0.8
0.5 1.0
P kW
P kW
P HP
0.2 0.3 0.4 0.6
0.2 0.4
0.1 0.2
0.1 0.2
0 0 0 0
5 5 16
15
NPSH m
NPSH m
4 4
12
NPSH ft
NPSH ft
3 10 3
8
2 2
5
1 1 4
0 0 0 0
72.145 72.141
0 Q m3/h 0.2 0.4 0.6 0.8 1 1.2 0 Q m3/h 0.5 1 1.5 2
600 400
TP 100 120
T 100
110
Ø 100 500
150
Ø 100
H ft
100
Hm
Hm
H ft
400 90 300
100 80
300
70
60 200 60 200
0 3 0.5 1 1.5 2 2.5 0 3 1 2 3 4 5
Q m /h Q m /h
0 l/min 10 20 30 40 0 l/min 20 30 40 50 60 70 80
0 l/s 0.1 0.2 0.3 0.4 0.5 0.6 0 l/s 0.2 0.4 0.6 0.8 1 1.2
3 4.0 5
3.5 6
4
P kW
3.0
P HP
P HP
P kW
5
2
2.5
3 4
2.0
1.5 3
1 2
5
6 20
NPSH m
NPSH m
14
NPSH ft
NPSH ft
15 4
4 12
10 10
2 3
5 8
0 0 2 6
0 0.5 1 1.5 2 72.142 2.5 0 1 2 3 4 72.140 5
Q m3/h Q m3/h
206
T, TP Peripheral Pumps
T 125
600 TP 132
TP 132R
300 1000
150 500
H ft
Hm
Hm
H ft
Ø 124 400
200
100 TP 132 Ø 132
300 TP 132R Ø 126 500
100
200
50 60 200
3 3
0 1 2 3 4 5 0
Q m /h Q m /h 1 2 3 4 5 6 7
0 l/min 20 30 40 50 60 70 80 0 l/min 20 40 60 80 100
0 l/s 0.2 0.4 0.6 0.8 1 1.2 0 l/s 0.4 0.6 0.8 1 1.2 1.4 1.6 1.8
7 16
20
6 8 16
10
P kW
P kW
5
P HP
P HP
12
6 TP 132
4 TP 132R
8
3 4 4
2 0 0
10 10
30 30
NPSH m
NPSH m
8 8
NPSH ft
NPSH ft
6 20
6 20
4
4 10
10 2
2 0 0
72.143 72.144
0 Q m3/h 1 2 3 4 5 0 Q m3/h 1 2 3 4 5 6 7
207
T, TP Peripheral Pumps
Features
Range
The high number of pumps in the range can meet the widest range of services
required by the user.
Flexible
The option to choose between cast iron and bronze materias for the hydraulic
parts in contact with the pumped liquid allows T-TP series pumps to be selected
for use with different types of liquids.
Reliable
The bearing and shaft are designed to ensure the reduction of the stress, provi-
ding high reliability under all operating conditions.
Optimized hydraulics
The pump hydraulics are designed to ensure high performance and consistency
of performance.
208
03/2021
Construction
Close-coupled self-priming liquid ring pumps with star impeller
and anti-lock wear ring.
CA: version with pump casing and lantern bracket in cast iron.
B-CA: version with pump casing and lantern bracket in bronze
(the pumps are supplied fully painted).
Applications
For clean liquids without abrasives, without suspended solids,
non-explosive, non-aggressive for the pump materials.
If the liquid to be pumped has entrained air or gas or the flow in
the suction pipe is not stable.
For drawing water out of a well.
For increasing network pressure (follow local specifications).
Operating conditions
Liquid temperature from -10 °C to +90 °C.
Ambient temperature up to 40 °C.
Negative suction pressure up to 9 m.
Maximum permissible working pressure: 6 bar.
Continuous duty.
Motor
2-pole induction motor, 50 Hz (n ≈ 2900 rpm).
CA: three-phase 230/400 V ± 10%.
CAM: single-phase 230 V ± 10%, with thermal protector.
Capacitor inside the terminal box.
Insulation class F.
Materials Protection IP 54.
Classification scheme IE3 for three-phase motors from 0,75 kW.
Components CA B-CA Constructed in accordance with: EN 60034-1; EN 60034-30-1.
Pump casing Cast iron Bronze EN 60335-1, EN 60335-2-41.
Lantern bracket GJL 200 EN 1561 G-Cu Sn 10 EN 1982
Impeller Brass P- Cu Zn Pb 2 UNI 5705
Special features on request
- Other voltages.
Shaft Chrome steel Cr-Ni-Mo steel - Frequency 60 Hz (as per 60 Hz data sheet).
1.4104 EN 10088 1.4401 EN 10088 - Protection IP 55.
(AISI 430) (AISI 316) - Special mechanical seal
- Higher or lower liquid or ambient temperatures.
Mechanical seal Carbon - Ceramic - NBR
- Construction with bearing bracket.
CA 91
H
m
150
CA 90
ft
40
CA 80
100
CA 60
20
50
0 0
0.1 m3 /h 0.5 1 2 3
Q l/min
2 5 10 20 30 40 50
72.863.C
209
CA Self-Priming Liquid Ring Pumps
P1 Maximum power input. P2 Rated motor power output. B-CA = Bronze construction. H Total head in m.
h2
H
h1
HA HS
4.93.217
K AA
w B A
BB AB
DN1 DN2 mm kg
TYPE
TIPO
ISO 228 a fM HS h2 h1 H BB B AB A AA K l2 l3 w HA CA B-CA
CA 60E - B-CA 60E G 1/
2 G 1/
2 18 256 63 25 103 158 96 80 122 100 22 7 45 14 103 8 6 6,8
CA 80E G 3/
4 G 3/
4 23 272 63 27 126 158 96 80 122 100 22 7 55 17 109 8 7,6 -
CA 90/A 10,8 -
G1 G1 28 318 71 41 142 182 106 90 134 112 22 7 63 21 128 10
CA 91/B 12,2 -
fM l2 l3
a DN2
DN1
h2
H
h1
HA HS
4.93.228
K AA
w B A
BB AB
DN1 DN2 mm kg
TYPE
TIPO
ISO 228 a fM HS h2 h1 H BB B AB A AA K l2 l3 w HA B-CA
B-CA 80/A G 3/
4 G 3/
4 23 307 71 27 134 182 106 90 134 112 22 7 55 17 122 10 10
B-CA 90/A 13,1
G1 G1 28 318 71 41 142 182 106 90 134 112 22 7 63 21 128 10
B-CA 91/B 14,7
210
CA Self-Priming Liquid Ring Pumps
Hm
H ft
H ft
40 80
10
30
20
60
20
5
10
40
0 0 10
3 3
0 0.2 0.4 0.6 0.8 1.0 0 0.5 1 1.5 2
Q m /h Q m /h
0 l/min 5 10 15 0 l/min 10 20 30
0.5 0.7
0.2
P kW
P kW
0.6
P HP
P HP
0.1 0.4
0.5
0.1
0.3 0.4
0.3
0 0 0.2
8 25 8 25
NPSH m
NPSH m
6 20 6 20
NPSH ft
NPSH ft
15 15
4 4
10 10
2 5 2 5
0 0 0 0
72.074 72.075
0 Q m3/h 0.2 0.4 0.6 0.8 1.0 0 Q m3/h 0.5 1 1.5 2
CA 90 CA 91 180
140 50 Ø 89.7 160
40 Ø 89.6
120 140
40
Hm
Hm
100 120
H ft
H ft
30
30 100
80
80
20
60 20
60
40 40
10 10
0 3 0.5 1 1.5 2 2.5 0 3 0.5 1 1.5 2 2.5
Q m /h Q m /h
0 l/min 10 20 30 40 0 l/min 10 20 30 40
0 l/s 0.1 0.2 0.3 0.4 0.5 0.6 0 l/s 0.1 0.2 0.3 0.4 0.5 0.6
1.0 1.0
1.2 1.2
0.8 0.8
1.0 1.0
P kW
P HP
P HP
P kW
NPSH m
6 20 6 20
NPSH ft
NPSH ft
15 15
4 4
10 10
2 5 2 5
0 0 0 0
0 Q m3/h 0.5 1 1.5 2 72.076 2.5 0 0.5 1 1.5 2 72.077 2.5
Q m3/h
211
CA Self-Priming Liquid Ring Pumps
Features
Flexible
The option to choose between cast iron and bronze materias for the hydraulic
parts in contact with the pumped liquid allows CA series pumps to be selected
for use with different types of liquids.
Easy maintenance
The construction features an anti-wear ring screwed to the pump body,
allowing for rapid replacement in case of wear.
212
03/2021
Construction
Close-coupled self-priming shallow-well pump with built-in
ejector.
Applications
For drawing water out of a well.
For lifting water containing air or other gases.
For increasing water pressure from flooded suction applications.
As pressure boosting pump for central water systems with low
pressure (follow local specifications if increasing network pres-
sure).
For garden use.
For washing with a jet of water.
Operating conditions
Liquid temperature: 0 °C to +35 °C.
Ambient temperature up to +40 °C.
Suction lift up to 9 m.
Maximum permissible pressure in the pump casing: 8 bar.
Continuous duty.
Motor
2-pole induction motor, 50 Hz (n ≈ 2800 rpm).
Materials NGL: three-phase 230/400 V ± 10%.
NGLM: single-phase 230 V ± 10%, with thermal protector.
Component Material
Capacitor inside the terminal box.
Pump casing Cast iron GJL 200 EN 1561 Insulation class F.
Casing cover Cr-Ni steel 1.4301 EN 10088 (AISI 304) Protection IP 54.
Impeller PPO-GF20 (Noryl) Classification scheme IE3 for three-phase motors from 0,75 kW.
Wear ring impeller-diffuser Cr-Ni steel 1.4301 EN 10088 (AISI 304) Constructed in accordance with: EN 60034-1; EN 60034-30-1.
EN 60335-1, EN 60335-2-41.
Diffuser PPO-GF20 (Noryl)
Ejector PPO-GF20 (Noryl)
Shaft Chrome steel 1.4104 EN 10088 (AISI 430) Special features on request
Mechanical seal Carbon - Ceramic - NBR - Other voltages.
- Frequency 60 Hz (as per 60 Hz data sheet).
50
H 150
m
40
ft
30 100
NGL 4/110
20 NGL 3/100
NGL 2/80
50
10
0 m 3/h 1 2 3 4 5
0 Q l/min 10 20 30 40 50 60 70 80
72.1072.1
213
NGL Self-Priming Pumps
50 50
H 150 H 150
m m
9
40 40
HS = 9m ft ft
8
HS = 9m
8 7
100 8 100
30 7 6 30 7
5
6 4 6
3 NGL 3/100 5
5 2 4
4 3
3 1 2
20 2 20 1 NGL 4/110
1 NGL 2/80
50 50
10 HS = 0m 10 HS = 0m
0 m3/h 1 2 3 4 0 m3/h 1 2 3 4 5 6
0 Q l/min 20 40 60 0 Q l/min 20 40 60 80 100
72.1072.1 72.1072.1
Self-priming capability
10
0 0
NGL 10 0 11
3/ 2/8 4/ 30
0,5 m 9
0,5 m
Hs ft
8
m 25
72.1072.3 7
Check valve.
Valvola di
6 20
non ritorno
5
Hs 15
4
G1 DN 25
(Øi 28 mm)
3 10
2
5
1
214
NGL Self-Priming Pumps
fM
115
G1 ISO 228 161
51
H
116
ISO 228
G1
4.93.367
33 9 30
10
95 8 112
210 w1 146
Dimensions
Dimensioni Net weight
Peso netto
TYPE
TIPO mm kg
fM H w1 NGL NGLM
NGL 2/80 362 176 102 9,8 9,9
NGL 3/100 391 192 112 11,1 12,1
NGL 4/110 391 192 112 13,1 13,1
215
NGL Self-Priming Pumps
Features
3.93.122
* Patented
Reliable
With new design features the NGL is more robust and forgiving when temporary abnormal
operating conditions may exist.
Compact
The NGL is smaller than conventional pumps of a similar type, allowing for installation in
restricted spaces and providing for easier retrofit applications.
Safe
Fast air evacuation reduces the risk of air-pockets developing at the mechanical seal
preventing the danger of seal failure due to a lack of flushing and cooling.
Better self-priming
The NGL are capable of lifting water from depths of 9 m in less than 3 minutes, offers new
possibilities on suction lift applications and provides better trouble free service on normal
shallow-well suction lift duties, also with a long suction pipe above the water level.
Low noise
The new diffuser and flow control device* guide the fluid from the impeller into the central
part of the pump casing, reducing turbulence and velocity, with effective use of the
surrounding liquid in dampening the noise of flow.
216
03/2021
Construction
Close-coupled self-priming shallow-well pump with built-in
ejector.
A high-quality pump for domestic water supply. Designed with
environmental considerations, featuring a stainless steel casing.
Applications
For drawing water out of a well.
For lifting water containing air or other gases.
For increasing water pressure from flooded suction applications.
As pressure boosting pump for central water systems with low
pressure (follow local specifications if increasing network
pressure).
For garden use.
For washing with a jet of water.
Operating conditions
Liquid temperature: 0 °C to +35 °C.
Ambient temperature up to +40 °C.
Suction lift up to 9 m.
Maximum permissible pressure in the pump casing: 8 bar.
Continuous duty.
Motor
2-pole induction motor, 50 Hz (n ≈ 2800 rpm).
NGX: three-phase 230/400 V ± 10%.
Materials NGXM: single-phase 230 V ± 10%, with thermal protector.
Component Material Capacitor inside the terminal box.
Pump casing Cr-Ni steel 1.4301 EN 10088 (AISI 304) Insulation class F.
Casing cover Cr-Ni steel 1.4301 EN 10088 (AISI 304) Protection IP 54.
Impeller Brass P-Cu Zn 40 Pb 2 UNI 5705 Classification scheme IE3 for three-phase motors from 0,75 kW.
(PPO-GF20 (Noryl) for NGX 2/80,3/100,4/110) Constructed in accordance with: EN 60034-1; EN 60034-30-1.
Wear ring impeller-diffuser Cr-Ni steel 1.4301 EN 10088 (AISI 304) EN 60335-1, EN 60335-2-41.
Diffuser PPO-GF20 (Noryl)
Ejector PPO-GF20 (Noryl) Special features on request
Shaft Chrome steel 1.4104 EN 10088 (AISI 430) - Other voltages.
Cr-Ni steel 1.4305 EN 10088 (AISI 303) for NGX 6 - Frequency 60 Hz (as per 60 Hz data sheet).
Mechanical seal Carbon - Ceramic - NBR
60 200
50 NG
X4 NGX 6/18
/16
H 150
m
40
ft
30 100
NGX
4/18
NGX 6/22
20 NGX 3/100
NGX 2/80 NGX 4/110
NGX 4/22 50
10
0 m3/h 1 2 3 4 5 6 7 8 9
0 Q l/min 10 20 30 40 50 60 70 80 90 100 110 120 130 140 150
72.1072.1
217
NGX Self-Priming Pumps
3~ 230V 400V 1~ 230V P1 P2 m3/h 0 0,3 0,5 1 2 2,4 3 4 4,5 5 5,5 6 6,5 7 8 8,4
Q
A A A kW kW HP l/min 0 5 8,3 16,6 33,3 40 50 66,6 75 83,3 91,6 100 108 116 133 140
NGX 4/16 4,5 2,6 NGXM 4/16 7 1,6 1,1 1,5 57,5 54 52 47,3 40 37,5 34 28,5 26
NGX 4/18 4,5 2,6 NGXM 4/18 7 1,6 1,1 1,5 48 46 44 42,5 37 35 32,5 28,5 27 25
H
NGX 4/22 4,5 2,6 NGXM 4/22 7 1,6 1,1 1,5 m 35,5 34,8 34 33 30,5 29,5 28 25,3 24 23 22 21 20,3 19,5 18 17,5
NGX 6/18/A 7,5 4,3 NGXM 6/18 9,2 2 1,5 2 58 54,7 51,5 46 44 41,3 37 34,7 32,5 30,5 28,5
NGX 6/22/A 7,5 4,3 NGXM 6/22 9,2 2 1,5 2 46,5 45 43,5 40,5 39,3 37,5 35 33,5 32,5 31,2 30 28,5 27,5 25,5 24,5
P1 Max. power input. P2 Rated motor power output. Tolerances according to UNI EN ISO 9906:2012
Curve caratteristiche
Characteristic curvescon
fordiverse altezze
different di aspirazione
suction lifts Hs Hs
0 U.S. g.p.m. 5 10 15 20 0 U.S. g.p.m. 5 10 15 20 25 0 U.S. g.p.m. 10 15 20 25 30 35
NG
NG
X6
X
/18
4/
16
50 50 50
NG
NG
X4 NG
X
m 9 m /18 9 m /22
00
9
40 8 40 8 40
9 9
HS = 9m 7 ft 7 ft NG ft
8 X4
HS = 9m 8 6 /22 8
8 7 6
8 7 5 7
30 7 6 5 100 30 4 100 30 6 100
4 7 6
6 5 5 3 5
4 3 6 2 HS = 9m 4
5 5 4 1 3
3 2 3 8 2
4 2 1 4 2 1 1
3 3 7
20 2 1 20
2
20 6
1 NGX 4/110 5
1 4
NGX 2/80 3 2
50 50 1 50
10 HS = 0m 10 HS = 0m 10 HS = 0m
0 m3 /h 1 2 3 4 5 0 m3/h 1 2 3 4 5 6 0 m3 /h 2 3 4 5 6 7 8 9
0 Q l/min 20 40 60 80 0 Q l/min 20 40 60 80 100 0 Q l/min 50 100 150
72.1072.1 72.1072.1 72.1072.1
Self-priming capability
Capacità di autoadescamento
50 Hz (n ≈ 2800 1/min), H2O, T = 20°C, Pa = 1000 hPa (mbar)
10
0 0
10 0 11
18 3/ 2/8 4/ 16 30
9 6/ 2 4/
0,5 m 6/
2
0,5 m
Hs ft
8
4 /22 25
m
8
72.1072.3 7 4/1
Check valve.
Valvola di
6 20
non ritorno
G 1 DN 25 5
(Øi 28 mm) 15
NGX 2/80, 4
NGX 3/100,
Hs
NGX 4/110. NGX 2/80
3 NGX 3/100 10
NGX 4/110
G 11/4 DN 32 NGX 4/16
2
(Øi 36 mm) NGX 4/18
NGX 4/22
5
NGX 4/16, 1 NGX 6/18
NGX 4/18, NGX 6/22
NGX 4/22,
NGX 6. 0 Hs (m) Suction
Altezzalift.
di aspirazione
0 t min 1 2 3
t (min) Self-priming
Tempo di autoadescamento
time.
218
NGX Self-Priming Pumps
fM
a L
DN2
ISO 228
h2
H
ISO 228
DN1
h1
4.93.281
m2 m3 s b
g1
m1 n2
w w1 n1
Dimensions
Dimensioni Net weight
Peso netto
TYPE
TIPO DN1 DN2 mm kg
219
NGX Self-Priming Pumps
Features
3.93.122
* Patented
Reliable
With new design features the NGX is more robust and forgiving when temporary abnormal
operating conditions may exist.
Compact
The NGX is smaller than conventional pumps of a similar type, allowing for installation in
restricted spaces and providing for easier retrofit applications.
Safe
Fast air evacuation reduces the risk of air-pockets developing at the mechanical seal
preventing the danger of seal failure due to a lack of flushing and cooling.
Better self-priming
The NGX are capable of lifting water from depths of 9 m in less than 4 minutes, offers new
possibilities on suction lift applications and provides better trouble free service on normal
shallow-well suction lift duties, also with a long suction pipe above the water level.
Low noise
The new diffuser and flow control device* guide the fluid from the impeller into the central
part of the pump casing, reducing turbulence and velocity, with effective use of the
surrounding liquid in dampening the noise of flow.
220
03/2021
NG Self-Priming Pumps
Construction
Close-coupled self-priming shallow well jet pumps with
built-in ejector.
NG: version with pump casing and lanter bracket in cast iron.
B-NG: version with pump casing and lanter bracket in bronze
(the pumps are supplied fully painted).
Applications
For drawing water out of a well.
As pressure boosting pump for central water systems with
low pressure (follow local specifications if increasing network
pressure).
For clean liquids or slightly dirty surface water.
For garden use.
For washing with a jet of water.
Operating conditions
Liquid temperature up to 40 °C.
Ambient temperature up to 40 °C.
Maximum permissible working pressure up to 10 bar.
Continuous duty.
Motor
2-pole induction motor, 50 Hz (n ≈ 2900 rpm).
NG: three-phase 230/400 V ± 10%.
Materials NGM:single-phase 230 V ± 10%, with thermal protector.
Components NG B-NG Capacitor inside the terminal box.
Pump casing Insulation class F.
Cover with lantern bracket Cast iron Bronze
Diffuser plate GJL 200 EN 1561 G-Cu Sn 10 EN 1982 Protection IP 54.
Classification scheme IE3 for three-phase motors from 0,75 kW.
Impeller Brass P- Cu Zn 40 Pb 2 UNI 5705
Constructed in accordance with: EN 60034-1; EN 60034-30-1.
Shaft Cr steel 1.4104 EN 10088 Cr-Ni-Mo steel EN 60335-1, EN 60335-2-41.
(AISI 430) for NG 3-4 1.4401 EN 10088
Cr-Ni steel 1.4305 EN 10088 AISI 316
(AISI 303) for NG 5-6-7 Special features on request
Diffuser PPO-GF20 (Noryl)
- Other voltages. - Frequency 60 Hz (as per 60 Hz data sheet).
Nozzle PPO-GF20 (Noryl) - Protection IP 55.
Mechanical seal Carbon - Ceramic - NBR - Special mechanical seal
80
60 200 50
H
m ft H H 150
m ft m ft
60 200 50 NG 7/18 40 NG 7/22
NG 7/16
150
50 NG 6/22 100
40 NG 6/18 30
221
NG Self-Priming Pumps
P1 Max. power input. P2 Rated motor power output. B-NG, B-NGM = Bronze construction. Tolerances according to UNI EN ISO 9906:2012
222
NG Self-Priming Pumps
NG 3 180 NG 4 140
40 130
50 Ø 130
160
Ø 130
120
35
140
110
Hm
Hm
H ft
H ft
40
120 30 100
90
30 100
25
80
80
70
20 20
0 3
Q m /h 0.5 1 1.5 2 2.5 3 0 3 1 2 3 4
Q m /h
0 l/min 10 20 30 40 50 0 l/min 10 20 30 40 50 60 70
0 l/s 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0 l/s 0.2 0.4 0.6 0.8 1
0.7 0.7
0.9
0.9
0.6 0.8
P kW
P kW
P HP
P HP
0.6
0.8
0.7
0.5
0.6
0.7
0.4 0.5
8 25
NPSH m
NPSH m
6 20 20
NPSH ft
NPSH ft
15 5
4
10 10
2
5
0 72.163
0 0 72.164
0
0 Q m3/h 0.5 1 1.5 2 2.5 3 0 Q m3/h 1 2 3 4
223
NG Self-Priming Pumps
200
60 50
160
Ø 143 Ø 143
180
140
Hm
Hm
H ft
H ft
50 40
160
120
140
40 30 100
120
80
30 100 20
0 Q m3/h 1 2 3 4 0 Q m3/h 1 2 3 4 5 6
0 l/min 20 30 40 50 60 70 0 l/min 20 40 60 80 100
0 l/s 0.2 0.4 0.6 0.8 1 1.2 0 l/s 0.2 0.4 0.6 0.8 1 1.2 1.4 1.6
1.2
1.2 1.6
P kW
P kW
P HP
P HP
1.6
1.1 1.5
1.4
1.1 1.5 1.0
8 25 8 25
NPSH m
NPSH m
NPSH ft
NPSH ft
6 20 6 20
15 15
4 4
10 10
2 5 2 5
0 72.168
0 0 72.169
0
0 Q m3/h 1 2 3 4 0 Q m3/h 1 2 3 4 5 6
0 U.S. g.p.m. 10 20 30 40
40
120
NG 5/22
Ø 134
30 100
Hm
H ft
80
20
60
40
10
0 3 2 4 6 8 10
Q m /h
0 l/min 50 100 150
1.1 1.5
P kW
P HP
1.4
1.0
1.3
0.9
8 25
NPSH m
6 20
NPSH ft
15
4
10
2
5
0 72.170
0
0 Q m3/h 2 4 6 8 10
224
NG Self-Priming Pumps
NG 6/18 200
60 50
Ø 157 160
NG 6/22
180 Ø 157
NGM 6/18 140
Hm
Hm
Ø 149
H ft
H ft
50 40 NGM 6/22
160
Ø 149
120
140
40 30 100
120
80
30 100 20
0 m3/h 1 2 3 4 5 6 0 Q m3/h 2 4 6 8 10
Q
0 l/min 20 30 40 50 60 70 80 90 100 0 l/min 40 60 80 100 120 140 160
0 l/s 0.4 0.6 0.8 1 1.2 1.4 1.6 0 l/s 0.4 0.8 1.2 1.6 2 2.4
1.8 2.0
NG 6/18 2.4 2.6
1.7 NG 6/22
1.8 2.4
2.2
P kW
P kW
1.6
P HP
P HP
1.6 2.2
1.5 NGM 6/18 NGM 6/22
2.0 2.0
1.4 1.4
1.8
1.3 1.8
1.2 1.6
8 25
8 25
NPSH m
NPSH m
6 20
NPSH ft
NPSH ft
6 20
15 15
4 4
10 10
2 2
5 5
0 72.171
0 0 72.172
0
0 Q m3/h 1 2 3 4 5 6 0 Q m /h
3 2 4 6 8 10
225
NG Self-Priming Pumps
Hm
250 200
H ft
H ft
60
70 230
180
210
50
60 160
190
140
170
50 40
0 3 1 2 3 4 5 0
Q m /h 1
3 2 3 4 5 6 7
Q m /h
0 l/min 20 30 40 50 60 70 80 0 l/min 20 40 60 80 100
0 l/s 0.2 0.4 0.6 0.8 1 1.2 0 l/s 0.4 0.6 0.8 1 1.2 1.4 1.6 1.8
2.3 2.2
3.0 2.9
2.1
2.1 2.8
P kW
P kW
2.8
P HP
P HP
2.0 2.7
1.9 2.6
1.9 2.6
2.4 2.5
1.7 1.8
10 10
30 30
NPSH m
NPSH m
8 8
NPSH ft
NPSH ft
6 20 6 20
4 4
10 10
2 2
0 72.178
0 0 72.173
0
0 Q m3/h 1 2 3 4 5 0 Q m3/h 1 2 3 4 5 6 7
0 U.S. g.p.m. 10 20 30 40
70
220
NG 7/22
200
60
Ø 164
180
Hm
H ft
50
160
140
40
120
30 100
3
0 Q m /h 2 4 6 8 10
0 l/min 40 60 80 100 120 140 160
P HP
1.9 2.6
1.8
2.4
1.7
1.6 2.2
8 25
NPSH m
6 20
NPSH ft
15
4
10
2
5
0 72.174
0
0 Q m3/h 2 4 6 8 10
226
NG Self-Priming Pumps
fM
a2 a1
DN2
h2
DN1
h1
g
4.93.104
m2 m3 s b
m1 n2
w n1
mm kg
DN1 DN2
TYPE
TIPO
ISO 228 a1 a2 fM h1 h2 H m1 m2 m3 n1 n2 b s w g NG B-NG
Installation examples
≥1m
Check valve.
3.93.100.1
4.93.100
Check valve.
227
NG Self-Priming Pumps
Features
3.94.116
Robust
The mechanical structure of the hydraulic parts in contact with the pumped liquid
are dimensioned to guarantee the maximum resistence to mechanical stress.
Self priming
The hydraulic design allows the pump to self prime even with the high suction
lifts or with long suction pipe runs above the water level.
Flexible
The option to choose between cast iron and bronze materias for the hydraulic
parts in contact with the pumped liquid allows NG series pumps to be selected
for use with different types of liquids.
228
03/2021
Construction
Horizontal multi-stage, self-priming, close coupled
pump.
Single-piece barrel casing in chrome-nickel stainless
steel, with front suction port above pumps axis and
radial delivery at top.
Stages in Noryl.
Applications
For water supply.
For domestic use, for garden use and irrigation.
Operating conditions
Liquid temperature: 0 °C to +35 °C.
Ambient temperature up to +40 °C.
Suction lift up to 8 m.
Maximum permissible pressure in the pump casing: 8 bar.
Continuous duty.
Motor
2-pole induction motor, 50 Hz (n ≈ 2800 rpm).
MXA: three-phase 230/400 V ± 10%.
MXAM: single-phase 230 V ± 10%, with thermal protector.
Capacitor inside the terminal box.
Materials Insulation class F.
Component Material Protection IP 54.
Classification scheme IE3 for three-phase motors from 0,75 kW.
Pump casing Cr-Ni steel 1.4301 EN 10088 (AISI 304) Constructed in accordance with: EN 60034-1; EN 60034-30-1.
Casing cover Cr-Ni steel 1.4301 EN 10088 (AISI 304)
EN 60335-1, EN 60335-2-41.
Pump Shaft Chrome steel 1.4104 EN 10088 (AISI 430)
Plug Cr-Ni steel 1.4305 EN 10088 (AISI 303)
Suction casing PPO-GF20 (Noryl) Special features on request
Stage casing PPO-GF20 (Noryl) - Other voltages.
Impeller PPO-GF20 (Noryl)
- Frequency 60 Hz (as per 60 Hz data sheet).
Mechanical seal Carbon - Ceramic - NBR - Protection IP 55.
60 Self-priming
Hs h (mm)
capability (m)
≤ 203 204 205 403 404 405
50
MXA H2O, T = 20°C, 2 100 100 500 100 100 500
205 405 Pa = 1000 hPa (mbar) 4 200 200 500 450 450 500
H 150 50 Hz (n ≈ 2800 1/min) 6 450 450 500 600 600 600
m
Hs 8 600 600 600 600 600 600
40 204 8
404 ft 3
MXA 205
20 404 25
4
m
20
h 7
100 0,5 m ft
403
5
30
40
203 6 20
403
20 72.1141 5
Check valve 15
50 4
10 Hs
0 8 G 1 DN 25
m3/h 2 4 6 3 10
Q l/min (Øi 28 mm)
0 50 100
60 8
NPSH NPSH 2
G 1 1/4 DN 32
50 6 (Øi 36 mm) 5
η η m
MXA 205,405 1
4
%
30 2 0
0 t min 1 2 3 4 5
20 0
0 Q m3/h 2 4 6 72.1140 8 Hs (m) Suction lift t (min) Self-priming time
229
MXA Multi-Stage Self-Priming Pumps
H
ISO 228
DN1
h1
4.93.281
m2 m3 s b
g1
m1 n2
w w1 n1
Dimensions
Dimensioni Net
Pesoweight
netto
TYPE
TIPO DN1 DN2 mm kg
ISO 228 fM a w h1 h2 H L m1 m2 m3 n1 n2 b s g1 w1 MXA MXAM
MXA 203 - MXAM 203 G1 G1 362 115 95 116 61 176 161 33 25 8 146 112 30 9 10 102 6,6 6,7
MXA 204/A - MXAM 204/A G1 G1 391 115 95 116 61 192 161 33 25 8 146 112 30 9 10 112 8,7 9,6
MXA 205/B - MXAM 205/A G 1 1/4 G1 462 140 113 152 68 225 213,5 37,5 28 9,5 185 155 33 9,5 11 147 13,3 13,8
MXA 403/A - MXAM 403/A G1 G1 391 115 95 116 61 192 161 33 25 8 146 112 30 9 10 112 8,6 9,5
MXA 404/B - MXAM 404/A G1 G1 391 115 95 116 61 192 161 33 25 8 146 112 30 9 10 112 9,5 10,5
MXA 405/A - MXAM 405/A G 1 1/4 G1 462 140 113 152 68 225 213,5 37,5 28 9,5 185 155 33 9,5 11 147 14,2 14,5
Features
Extra safety
against running dry, with the suction port above
pump axis and with the self-priming construction.
Robust
Single-piece barrel casing.
Compact
Single-piece lantern bracket and base.
Low noise
with the water-filled shroud around the stages.
3.93.124
230
03/2021
I, IR Gear Pumps
Construction
Close-coupled gear pumps (rotary pumps).
Pump casing with suction and delivery connections with the
same diameter and on the same axis (in-line execution).
Applications
For fuel oil and liquids with lubricating properties.
Operating conditions
Kinematic viscosity from 30 mm2/s (4°E) to 120 mm2/s (15°E).
Liquid temperature up to 90 °C.
Ambient temperature up to 40 °C.
Total suction lift up to 4 m.
Continuous duty.
Motor
4-pole induction motor, 50 Hz (n ≈ 1450 rpm).
I, IR, IRR: three-phase 230/400 V ± 10%.
IM: single-phase 230 V ± 10%.
Insulation class F.
Protection IP 54.
Materials Classification scheme IE3 for three-phase motors from 0,75 kW.
Constructed in accordance with: EN 60034-1; EN 60034-30-1.
Components Materials EN 60335-1, EN 60335-2-41.
Pump casing Cast iron GJL 200 EN 1561
231
I, IR Gear Pumps
319 140
I 25/4 /A: 10 kg 35 120
IM 25/4 /A: 11,7 kg
ISO 228
ISO 228
IR 25/4 /A: 11,6 kg
G1
G1
182
88
10
4.93.224
Ø10 22
107.5 90 112
106 134
408 160
IRR 25/4/B: 17,6 kg 35 120
ISO 228
ISO 228
G1
G1
205
97
10
4.93.065
Ø 9.5 30
125 100 125
117 155
Features
Innovative structure
The flanged pump casing and two piece shaft allows the hydraulics to be
disassembled easier, facilitating quick maintenance operations.
232
03/2021
Construction
Vertical column sump pumps, with motor in dry installation and
with pump body submerged in the liquid handled (without suc-
tion line or foot valve).
Impeller - VAL: free-flow impeller (vortex or recessed
impeller).
- SC: open impeller.
Connection - VAL 30, SC 30, SC 50: threaded port ISO 228 (BS 2779).
- VAL 65: flange with plain face oval threaded
counter-flange UNI 2245, PN 2,5.
Applications
For draining a basin or a sump with domestic or industrial sewage.
For slightly dirty waste water, for liquids which are non-aggessive
for the pump materials.
Operating conditions
Liquid temperature up to 40 °C.
Ambient temperature up to 40 °C.
Continuous duty.
Maximum size of solids: VAL 30 = 25 mm; VAL 65 = 50 mm;
SC 30 = 3 mm; SC 50 = 6 mm.
Motor
2-pole induction motor, 50 Hz (n ≈ 2900 rpm).
VAL -SC: three-phase 230/400 V ± 10%.
Materials
VALM-SCM: single-phase 230 V ± 10%, with thermal protector.
Components VAL SC
Insulation class F.
Pump casing Cast iron Cast iron
Lower bearing housing* GJL 200 EN 1561 GJL 200 EN 1561
Protection IP 54.
Classification scheme IE3 for three-phase motors from 0,75 kW.
Impeller Brass P-Cu Zn 40 Pb 2 UNI 5705
for VAL 30 Brass
Constructed in accordance with: EN 60034-1; EN 60034-30-1.
Cast iron GJL 200 EN 1561 P-Cu Zn 40 Pb 2 UNI 5705 EN 60335-1, EN 60335-2-41.
for VAL 65
Shaft Steel C 40 UNI 7231 Special features on request
Bearing bush Tecnopolymer - Other voltages.
Shaft sleeve Chromate bronze _ - Frequency 60 Hz (as per 60 Hz data sheet).
for VAL 65 - Protection IP 55.
* Not existing for VAL 30. - Bronze bearing bush (for liquid up to 100 °C).
6 20 H
H
m ft
20
4
65 5
65R 10
30 30 50
2 3 10
3 3
1 m /h 5 10 50 70 1 m /h 5 10 20 30
Q l/min Q l/min
20 50 100 200 500 1000 20 50 100 200 500
72.869.C
233
VAL, SC Vertical Submerged Pumps
Q
3~ 230V 400V 1~ 230V P1 P2 m3/h 3 3,5 4 4,5 5 5,5 6 6,5 7 7,5 8 9 10 12 14 16 18 20 25 30
A A A kW kW HP l/min 50 58,3 66,6 75 83,3 91,6 100 108 116 125 133 150 166 200 233 266 300 333 416 500
VAL 30/A 2,3 1,3 VALM 30/A 3,6 0,63 0,45 0,6 6,7 6,5 6,2 5,9 5,6 5,3 5 4,7 4,3 4 3 2
VAL 65/A 7,5 4,3 1,5 2 7,1 6,9 6,6 6,3 6 5,6 5,3 4,5 3,7
VAL 65-R/B
H
9,15 5,3 2,2 3 7,1 6,9 6,6 6,3 6 5,6 5,3 4,5 3,7
m
SC 30/A 2,3 1,3 SCM 30/A 2,8 0,47 0,37 0,5 11 10,6 10,2 9,6 9 8,3 7,4 6,5 5,4 4
SC 50/A 2,3 1,3 SCM 50/A 3,6 0,69 0,45 0,6 10,3 10,2 10,1 10 9,9 9,8 9,7 9,4 9 8 6,7 5 3
P1 Max. power input. P2 Rated motor power output. H Total head in m. Tolerances according to UNI EN ISO 9906:2012
M
CALPEDA
fM
fM
L max
1)
L max
1)
DN
DN
VAL 30 L min
L min
SC 30 h2
VAL 65 h2
SC 50 VAL 65-R
l1 l2 l1 l2
l l
AD AD
4.93.173 4.93.058
DN mm
TYPE
ISO 228 fM M h2 AD a L min L max l l1 l2 kg
VAL 30/750/A 1025 750 17,8
G 1 1/4 200 82 111 120 150 180 90 148
VAL 30/1000/A 1275 1000 19,5
VAL 65/1000/A 1245 950 40
VAL 65/1500/A 1745 1450 48
G 2 1/2 235 140 135 140 250 175 88 195
VAL 65/2000/A 2245 1950 56
VAL 65/2500/A 2745 2450 64
VAL 65/1000-R/B 1285 950 43
VAL 65/1500-R/B 1785 1450 51
G 2 1/2 275 140 135 140 250 175 88 195
VAL 65/2000-R/B 2285 1950 59
VAL 65/2500-R/B 2785 2450 67
SC 30/500/A 765 455 17,4
SC 30/750/A 1015 705 19,6
G 1 1/4 200 105 111 100 200 132 65 127
SC 30/1000/A 1265 955 21,8
SC 30/1250/A 1515 1205 24
SC 50/500/A 780 470 18,5
SC 50/750/A 1030 720 20,7
G2 200 120 111 120 215 173 86 157
SC 50/1000/A 1280 970 22,9
SC 50/1250/A 1530 1220 25,1
234
VAL, SC Vertical Submerged Pumps
6 20 6 20
Hm
Hm
H ft
H ft
15 15
4 4
10 10
2 2
5 5
0 0 0 0
3 3
0 2 4 6 8 10 12 0
Q m /h Q m /h 5 10 15 20 25 30
0 l/min 50 100 150 200 0 l/min 100 200 300 400 500
P kW
0.3 0.4
P HP
P HP
1.5
1
0.2 0.3
1.0
0.2
0.1 0.5
0.1
0 0 0 0
0 Q m3/h 2 4 6 8 10 72.181 12 0 Q m3/h 5 10 15 20 25 72.182 30
40 35
Ø 95.5 SC 30 10
Ø 95
SC 50
30
10
30 25
Hm
Hm
H ft
H ft
20
20 5
15
5
10
10
5
0 0 0 0
3 3
0 2 3 4 5 6 7 8 0 5 10 15 20
Q m /h Q m /h
0 l/min 20 40 60 80 100 120 0 l/min 50 100 150 200 250 300
0 l/s 0.4 0.6 0.8 1 1.2 1.4 1.6 1.8 2 2.2 0 l/s 1 2 3 4 5
0.3 0.4 0.5
0.6
0.4
0.3 0.5
0.2
P kW
P kW
0.3 0.4
P HP
P HP
0.2
0.2 0.3
0.1 0.2
0.1 0.1
0.1
0 0 0 0
0 Q m3/h 2 3 4 5 6 7 72.185 8 0 Q m3/h 5 10 15 72.184 20
235
VAL, SC Vertical Submerged Pumps
Features
Range
The high number of pumps in the range can meet the widest range of services
required by the user.
Float switch
The pumps can be fitted with a float switch, eliminating the need for level control
systems.
236
03/2021
Construction
Submersible drainage pump constructed with composite poly-
mers developed especially for this product.
These new rustproof materials are resistant to corrosion,
indeformable at maximum temperature differentials in the pump
and motor and resistant to internal and external strain.
Shaft of chrome steel AISI 430. Three lip seals in NBR.
With float switch for automatic start/stop.
Applications
For clean or slightly dirty water.
For draining flooded rooms or tanks.
Extraction of water from ponds, flowing water or pits for collec-
tion of rain water. For irrigation purposes.
For use outdoor, the power supply cable shall have a length not
less than 10 m.
Operating conditions
Maximum liquid temperature for prolonged use: 35 °C (with
immersed motor).
Immersion depth: 5 m max (with suitable cable length).
Not suitable for continuous duty for prolonged time.
Motor
2-pole induction motor, 50 Hz (n ≈ 2900 rpm). Special features on request
Single-phase 230 V ± 10%, with thermal protector. Other voltages.
Capacitor inserted in the housing incorporated in the plug. Frequency 60 Hz (as per 60 Hz data sheet).
Cable: with plug, length 5 m, 245IEC57 4 G 0,75 mm2, according to EN 60335-2-41 Cable H07RN8-F, 4 G 1 mm2, length 10 m, without plug.
for pumps up to 5 kg. Control box with capacitor, for pumps with cable without plug.
Insulation class B. Without float switch.
Protection IP X8. With elbow on discharge port.
Triple impregnation humidity-proof dry winding.
H ft
m
6 20
10
2 1~ m3/h 0
Capacitor P1
230V Condensatore P2 3 6 9 12
Q
A μF V kW kW HP l/min 0 50 100 150 200
GM 10 1,75 6,3 450 0,4 0,3 0,4 Hm 7,5 6,5 5,2 3,7 2,2
0 3
0
0 m /h 3 6 9 12 P1 Max. power input
0
Q 50 100 150 200 P2 Rated motor power output
l/min
H Total head in m
237
GM 10 Submersible Drainage Pump
G 1 1/2
212
179
200
40
4.93.119
4.93.130
168 M20x1,5
Maximum reliability
A metal support ensures correct alignment between the pump shaft
and the motor also in heavy duty conditions.
A threaded metallic insert in the delivery port allows for secure
connection of the delivery pipe or fitting without any risk of damaging
the pump.
A suction strainer prevents solids bigger than 8 mm grain size from
entering the pump.
Compact
Minimum dimension and high levels of performance, for use in many
different applications, for flow rates up to 200 liters/min.
Avviamento
On
300
212
Arresto
40
100
Off
3.93.004/2
179 max
G 1 1/2
ISO 228 min 350 x 350
238
03/2021
Construction
Single-impeller submersible pumps in chrome-nickel stainless
steel, with vertical delivery port.
GXR: with open impeller.
GXV: with free-flow (vortex) impeller.
Motor cooled by the pumped water passing between the motor
jacket and the external jacket.
Double shaft seal with oil chamber.
Applications
GXR: - For clean water containing solids up to 10 mm grain size.
- For draining rooms or or emptying tanks.
- Extraction of water from ponds, streams or pits and
for rainwater collection.
- For irrigation purposes.
GXV: - For clean or slightly dirty water, containing solids up to
25 mm grain size.
- Particularly suitable for liquids with a high solid content.
For outdoor use a power supply cable of not less than 10 m
should be used in accordance with: EN 60 335-2-41.
Operating conditions
Liquid temperature up to 50° C.
Maximum immersion depth: 5 m.
Minimum water level with float: GXR = 70 mm, GXV = 130 mm.
Minimum water level manual operation: GXR = 15 mm, GXV = 30 mm.
Continuous duty.
Materials
Component Material
Motor
Pump casing 2-pole induction motor, 50 Hz (n ≈ 2900 rpm).
Strainer GXR, GXV: three-phase 230 V ± 10%;
Impeller Chrome-nickel steel 1.4301 EN 10088 (AISI 304) three-phase 400 V ± 10%;
Motor jacket
Pump jacket GXRM, GXVM: single-phase 230 V,
with float switch and thermal protector.
Handle Polypropylene
Incorporated capacitor.
Shaft Chrome-nickel steel 1.4305 EN 10088 (AISI 303)
Insulation class F.
Mechanical seal Ceramic alumina/Carbon/NBR Protection IP X8 (for continuous immersion)
Seal lubrication oil Oil for food/pharmaceutical machinery Double impregnation humidity-proof dry winding.
Constructed in accordance with: EN 60034-1;
Other features on request EN 60335-1, EN 60335-2-41.
- Other voltages. - Frequency 60 Hz. - Other mechanical seal. - Cable length 10 m.
- Vertical magnetic float switch. - Motor suitable for operation with frequency converter.
GX ft ft
R
10 13 10
GX
R 30 GX 30
11 V2
5-1
H H 0
GX
m GX m V2
R 5-8
9
6 20 6 20
GX
V2
5-6
4 4
10 10
2 2
0 0 0 0
0 m3/h 5 10 15 0 m3/h 5 10 15
Q Q
0 l/min 50 100 150 200 250 0 l/min 50 100 150 200 250
239
GXR, GXV Submersible Pumps
in stainless steel
3~ 230V 400V 1~ 230V Capacitor P1 P2 m3/h 0 1,2 3 4,5 6 7,5 9 10,2 12 13,2
Q
A A A Vc kW kW HP l/min 0 20 50 75 100 125 150 170 200 220
GXV 25-6 1,6 0,9 GXVM 25-6 2,5 8 450 0,5 0,25 0,33 6 5,7 5,2 4,5 3,8 3 2,2 1,5
GXV 25-8 2,3 1,3 GXVM 25-8 3,5 12,5 450 0,7 0,37 0,5 Hm 8,2 7,8 7,2 6,7 6,1 5,4 4,5 3,6 2,2
GXV 25-10 2,8 1,6 GXVM 25-10 4,5 16 450 0,95 0,45 0,6 10 9,5 8,7 8 7,3 6,5 5,7 4,9 3,7 2,6
P1 Max. power input. P2 Rated motor power output. Density ρ = 1000 kg/m . 3
Kinematic viscosity ν = max 20 mm /sec. 2
fM a fM a
Ø 25
Ø 10
4.93.388 4.93.411
176
176
G 1 1/4
ISO 228
ISO 228
G 1 1/4
56 56
240
GXR, GXV Submersible Pumps
in stainless steel
Installation examples
G 1 1/4 G 1 1/4
ISO 228 ISO 228
On
On
375
340 Off fM
Off fM
70 130
3.93.037/3 3.93.037/3
Ø 176 Ø 176
min 350 x 350 min 350 x 350
fM
h
h fM max
max
h h
min min
3.93.037/3 3.93.037/3
Ø 176 Ø 176
min 250 x 250 min 250 x 250
mm mm
TYPE TYPE
h h h h
fM min max fM min max
GXRM 9 GF 265 100 190 GXVM 25-6 GFA 302 70 150
GXRM 11 GF 300 135 225 GXVM 25-8 GFA 337 70 185
GXRM 13 GF 300 135 225 GXVM 25-10 GFA 337 70 185
241
GXR, GXV Submersible Pumps
in stainless steel
Features
PATENTED
Shaft in chrome-nickel
stainless steel.
Oil chamber.
242
GXR 12 Submersible Pumps
in stainless steel
Construction
Single-impeller submersible pumps in chrome-nickel stainless
steel, with vertical delivery port.
GXR: with open impeller.
Motor cooled by the pumped water passing between the motor
jacket and the external jacket.
Double shaft seal with oil chamber.
Applications
- For clean water containing solids up to 12 mm grain size.
- For draining rooms or emptying tanks.
- Extraction of water from ponds, streams or pits and for
rainwater collection.
- For irrigation purposes.
For outdoor use a power supply cable of not less than 10 m
should be used in accordance with: EN 60335-2-41.
Operating conditions
Liquid temperature up to 40° C.
Maximum immersion depth: 5 m.
Minimum water level with float: 70 mm,.
Minimum water level manual operation: 15 mm.
Continuous duty.
Motor
2-pole induction motor, 50 Hz (n ≈ 2900 rpm).
GXR: three-phase 230 V ± 10%;
three-phase 400 V ± 10%;
Cable: H07RN-F, 4G1 mm2, length 10 m, without plug.
GXRM: single-phase 230 V,
Materials with float switch and thermal protector.
Incorporated capacitor.
Component Material Cable: H07RN-F, 3G1 mm2 (3G1,5 mm2 for 1,1 kW,
Pump casing 3G2,5 mm2 for 1,5 kW), length 10 m, with plug CEI-
Strainer UNEL 47166.
Impeller Chrome-nickel steel 1.4301 EN 10088 (AISI 304) Insulation class F.
Protection IP X8 (for continuous immersion)
Motor jacket
Double impregnation humidity-proof dry winding.
Pump jacket Constructed in accordance with: EN 60034-1;
Handle Polypropylene (with frame in AISI 304) EN 60335-1, EN 60335-2-41.
Shaft Chrome-nickel steel 1.4301 EN 10088 (AISI 304)
Other features on request
Mechanical seal: upper - Other voltages. - Frequency 60 Hz.
Ceramic alumina/Carbon/NBR
lower - Other mechanical seal. - Cable length 20 m.
- Vertical magnetic float switch.
Seal lubrication oil Oil for food/pharmaceutical machinery
- Motor suitable for operation with frequency converter.
- Three-phase pumps with incorporated float switch.
18 60
GXR
12-20
H GXR
m 12-18 50
14 GXR 1 ft
2-16
GXR
12-14 40
12
GXR
10 12-1
2
30
GXR
8 12-1
0
6 20
4
10
2
0 0
0 m3/h 10 20 30
Q l/min
0 100 200 300 400 500
243
GXR 12 Submersible Pumps
in stainless steel
P1 Max. power input. P2 Rated motor power output. Density ρ = 1000 kg/m . 3
Kinematic viscosity ν = max 20 mm /sec.
2
4.93.601
228
G 1 1/2
ISO 228
80
mm kg (1)
TYPE
fM a GXR GXRM
GXR 12-10 - GXRM 12-10 360 310 10,3 11,3
GXR 12-12 - GXRM 12-12 375 325 11,5 12,5
GXR 12-14 - GXRM 12-14 400 350 13 14
GXR 12-16 - GXRM 12-16 400 350 13,6 14,6
GXR 12-18 - GXRM 12-18 420 370 14,4 15,9
GXR 12-20 - GXRM 12-20 450 400 16 17,5
(1) With cable length: 10 m
244
GXR 12 Submersible Pumps
in stainless steel
Installation examples
G 1 1/2
ISO 228
mm
TYPE
On
h h
fM min max
GXR 12-10 - GXRM 12-10 360 175 435
h GXR 12-12 - GXRM 12-12 375 190 450
max GXR 12-14 - GXRM 12-14 400 215 475
Off fM GXR 12-16 - GXRM 12-16 400 215 475
h GXR 12-18 - GXRM 12-18 420 235 495
min GXR 12-20 - GXRM 12-20 450 265 525
3.93.037/3
Ø 228
min 550 x 550
287,5
mm
TYPE
MAX h h
fM a min max
a MIN
h fM GXRM 12-10 GF 360 310 180 270
max GXRM 12-12 GF 375 325 195 285
h
min GXRM 12-14 GF 400 350 220 310
4.93.602
3.93.037/3 GXRM 12-16 GF 400 350 220 310
Ø 228
min 350 x 350
245
GXR 12 Submersible Pumps
in stainless steel
Features
PATENTED
Shaft in chrome-nickel
stainless steel.
Suction strainer with a double row of holes, for extra The double shaft seal with oil chamber separates the motor
safety against clogging with the passage of solids up to from the water and provides further protection against
12 mm grain size. accidental operation when dry.
246
GXVL Submersible Pumps
in stainless steel AISI 316L
Construction
Single-impeller submersible pumps in chrom-enickel-molybdenum
stainless steel AISI 316L, with vertical delivery port.
GXVL: with free-flow (vortex) impeller.
Motor cooled by the pumped water passing between the motor
jacket and the external jacket.
Double shaft seal with oil chamber.
Applications
For clean or slightly dirty water, containing solids up to 25 mm
grain size.
Particularly suitable for liquids with a high solid content.
For outdoor use a power supply cable of not less than 10 m
should be used in accordance with: EN 60 335-2-41.
Operating conditions
Liquid temperature up to 50° C.
Maximum immersion depth: 5 m.
Minimum water level with float 130 mm.
Minimum water level manual operation 30 mm.
Continuous duty.
Motor
2-pole induction motor, 50 Hz (n ≈ 2900 rpm).
GXVL: three-phase 230 V ± 10%;
three-phase 400 V ± 10%;
Cable: H07RN-F, 4G1 mm2, length 5 m, without plug.
GXVLM: single-phase 230 V,
with float switch and thermal protector.
Materials Incorporated capacitor.
Cable: H07RN-F, 3G1 mm2, length 5 m, with plug
Component Material CEI-UNEL 47166.
Pump casing
Insulation class F.
Strainer Protection IP X8 (for continuous immersion)
Impeller Cr-Ni-Mo steel 1.4404 EN 10088 (AISI 316L) Double impregnation humidity-proof dry winding.
Motor jacket Constructed in accordance with: EN 60034-1;
Pump jacket EN 60335-1, EN 60335-2-41.
Handle Polypropylene
Other features on request
Shaft Cr-Ni-Mo steel 1.4404 EN 10088 (AISI 316L) - Other voltages.
Mechanical seal Ceramic alumina/Carbon/NBR - Frequency 60 Hz.
- Other mechanical seal.
Seal lubrication oil Oil for food/pharmaceutical machinery - Cable length 10 m.
- Motor suitable for operation with frequency converter.
GXVL
12 40
ft
10
GX 30
VL
25-
H 10
m
6 20
4
10
2
0 0
0 m3/h 5 10 15
Q
0 l/min 50 100 150 200 250
247
GXVL Submersible Pumps
in stainless steel AISI 316L
P1 Max. power input. P2 Rated motor power output. Density ρ = 1000 kg/m . 3
Kinematic viscosity ν = max 20 mm /sec.
2
fM a
Ø 25
4.93.411
176
ISO 228
G 1 1/4
56
Dimensions (1)
TYPE mm kg
fM a GXVL GXVLM
GXVL 25-10 - GXVLM 25-10 337 302 6,8 7,3
(1) With cable length: 5 m
Installation examples
G 1 1/4
ISO 228
On
375
Off fM
130
3.93.037/3
Ø 176
min 350 x 350
248
03/2021
Construction
Single-impeller submersible pumps in chrome-nickel stainless
steel, with vertical delivery port and suction non-return valve.
Suction capability up to 1 mm from the bottom.
Motor cooled by the pumped water passing between the motor
jacket and the external jacket.
Double shaft seal with oil chamber.
The pump is fitted with a suction non-return valve which,
during operation, allows to manually move the pump to seve-
ral points in the room and draw water up to 1 mm avoiding that
the pump loses its priming.
Applications
For clean water containing solids up to 3 mm grain size.
For draining rooms or or emptying tanks.
Extraction of water from ponds, streams or pits and for
rainwater collection.
For irrigation purposes.
Operating conditions
Liquid temperature up to 35° C.
Maximum immersion depth: 5 m.
Minimum water level 1 mm.
Continuous duty.
Motor
2-pole induction motor, 50 Hz (n ≈ 2900 rpm).
GX ZERO: three-phase 230 V ± 10%;
three-phase 400 V ± 10%;
Cable: H05RN-F, 4G0,75 mm2, length 10 m,
Materials without plug.
GXM ZERO: single-phase 230 V,
Component Material with thermal protector.
Pump casing PA66-50FV (Noryl) Incorporated capacitor.
Impeller PPO-GF20 (Noryl) Cable: H05RN-F, 3G0,75 mm2, length 10 m,
with plug CEI-UNEL 47166.
Valve NBR / Chrome-nickel steel AISI 304 Insulation class F.
Motor jacket Protection IP X8 (for continuous immersion)
Chrome-nickel steel 1.4301 EN 10088 (AISI 304)
Pump jacket Double impregnation humidity-proof dry winding.
Strainer Constructed in accordance with: EN 60335-2-41.
Polypropylene
Handle
Shaft Chrome-nickel steel 1.4305 EN 10088 (AISI 303)
Other features on request
- Other voltages.
Mechanical seal Ceramic alumina/Carbon/NBR - Frequency 60 Hz.
Seal lubrication oil Oil for food/pharmaceutical machinery - Other mechanical seal.
- Motor suitable for operation with frequency converter.
10 GX ZERO
30
H ft
m
6 20
4
10
2
0 0
0 m3/h 2 3 4 5 6 7
Q
0 l/min 25 50 75 100
249
GX ZERO Submersible clean water pumps
Dimensions (1)
TYPE mm kg
G 1 1/4
ISO 228
fM a GX GXM
GX ZERO - GXM ZERO 297 261 5 5,2
(1) With cable length: 10 m
176
56
Installation examples
min. 1 mm 3.93.037/3
248
03/2021
Construction
PATENTED Single-impeller submersible drainage pump, with open impeller.
GQR: with vertical threaded delivery port (G 1 1/2).
GQR 10 32: with horizontal flanged and threaded delivery
port (DN 32, PN 6 - G 1 1/2).
Double mechanical shaft seal with interposed oil chamber, to
protect against dry-running.
Applications
For clean water containing solids up to 10 mm grain size.
For draining rooms or or emptying tanks.
Extraction of water from ponds, streams or pits and for rainwater
collection.
For irrigation purposes.
Operating conditions
Liquid temperature up to 35° C.
Maximum immersion depth: 5 m.
Minimum immersion depth: 205 mm.
Continuous duty (with submerged motor).
Motor
2-pole induction motor, 50 Hz (n ≈ 2900 rpm).
GQR: three-phase 230 V ± 10%;
three-phase 400 V ± 10%;.
Cable: H07RN-F, 4G1 mm2, length 10 m, without plug.
GQRM: single-phase 230 V ± 10%,
with float switch and thermal protector.
Incorporated capacitor.
Materials Cable: H07RN-F, 3G1 mm2, length 10 m, with plug
Component Material CEI-UNEL 47166.
Pump casing Insulation class F.
Cast iron GJL 200 EN 1561 Protection IP X8 (for continuous immersion)
Impeller
Triple impregnation humidity-proof dry winding.
Strainer
Constructed in accordance with: EN 60034-1;
Motor jacket
Chrome-nickel steel 1.4301 EN 10088 (AISI 304) EN 60335-1, EN 60335-2-41.
Jacket cover
Casing cover Other features on request
Handle Polypropylene (with frame in AISI 304) - Other voltages. - Frequency 60 Hz (as per 60 Hz data sheet).
Shaft Chrome-nickel steel 1.4301 EN 10088 (AISI 304) - Other mechanical seal.
Mechanical seal: upper - Cable length 20 m.
Ceramic alumina/Carbon/NBR - Vertical magnetic float switch.
lower
- Motor suitable for operation with frequency converter.
Seal lubrication oil Oil for food/pharmaceutical machinery
- Three-phase pumps with incorporated float switch.
6 20
4
10
2
0 0
0 m3/h 10 20 30
Q l/min
0 100 200 300 400 500
249
GQR Submersible Drainage Pumps
P1 Max. power input. P2 Rated motor power output. Density ρ = 1000 kg/m3. Kinematic viscosity ν = max 20 mm2/sec.
On On
h max
h max
Off
fM
Off
fM
G1 1/2
h min
h min
ISO 228
90
62
4.93.432 4.93.581
Ø 10 Ø 10
G1 1/2
ISO 228 Ø 90
247 245
DN 32 Ø 120
PN 6
190
190
430 430
mm kg (1) mm kg (1)
TYPE TYPE
fM h max h min GQR GQRM fM h max h min GQR GQRM
GQR(M) 10-10 390 410 205 14 15 GQR(M) 10 32-10 395 415 210 14,7 15,7
GQR(M) 10-12 405 425 220 14,5 15,5 GQR(M) 10 32-12 410 430 225 15,2 16,2
GQR(M) 10-14 405 425 220 14,5 15,5 GQR(M) 10 32-14 410 430 225 15,2 16,2
GQR(M) 10-16 430 450 245 16 18 GQR(M) 10 32-16 435 455 250 16,7 18,7
GQR(M) 10-18 450 470 265 17,5 19 GQR(M) 10 32-18 455 475 270 18,2 19,7
GQR 10-20 450 470 265 19 - GQR 10 32-20 455 475 270 19,7 -
GQRM 10-20 480 500 295 - 20,5 GQRM 10 32-20 485 505 300 - 21,2
1) With cable length: 10 m 1) With cable length: 10 m
250
GQR Submersible Drainage Pumps
Installation examples
500 min
285
12
86 190
52
On
3/4" mm
TYPE
h max h min
GQR(M) 10 32-10 487 282
G2 ISO 228
Off
h max
547 342
134
GQR 10 32-20
72
4.93.581/1
min 500 x 500
380
138 mm
TYPE
h h
On min max
16 GQRM 10-10 GF 225 315
Off
GQRM 10-12 GF 240 330
88
360 min
h
132
100
38
Installation examples
251
GQR Submersible Drainage Pumps
Features
PATENTED
Cable length 10 m, pump single-phase
with plug Handle in polypropylene, with
frame in stainless steel.
GQR .. 32
252
03/2021
Construction
PATENTED Single-impeller submersible pumps in chrome-nickel stainless
steel, with vertical delivery port.
GXC: with two-passage impeller.
GXV: with free-flow (vortex) impeller.
Double shaft seal with interposed oil chamber.
Applications
For clean and dirty water, also containing solids up to 35 mm
grain size.
The GXV free-flow impeller construction is particularly suitable
for liquids with a high solid content or with filamentous particles.
This construction (with smooth surfaces in rolled-stainless steel
and easy access for cleaning) is also suitable for certain uses in
the food industry.
Operating conditions
Liquid temperature up to 35 °C.
Minimum immersion depth: 250 mm.
Maximum immersion depth: 5 m.
Continuous duty (with submerged motor).
Motor
2-pole induction motor, 50 Hz (n ≈ 2900 rpm).
GXC, GXV: three-phase 230 V ± 10%;
three-phase 400 V ± 10%;.
Cable: H07RN-F, 4G1 mm2, length 10 m, without plug.
GXCM, GXVM: single-phase 230 V ± 10%,
Materials with float switch and thermal protector.
Incorporated capacitor.
Component Material Cable: H07RN-F, 3G1 mm2, length 10 m, with
Pump casing plug CEI-UNEL 47166.
Casing cover Insulation class F.
Impeller Chrome-nickel steel 1.4301 EN 10088 (AISI 304) Protection IP X8 (for continuous immersion)
Motor jacket Triple impregnation humidity-proof dry winding.
Jacket cover Constructed in accordance with: EN 60034-1;
EN 60335-1, EN 60335-2-41.
Handle Polypropylene (with frame in AISI 304)
Shaft Chrome-nickel steel 1.4301 EN 10088 (AISI 304) Other features on request
Mechanical seal: upper - Other voltages. - Frequency 60 Hz (as per 60 Hz data sheet).
Ceramic alumina/Carbon/NBR - Other mechanical seal. - Cable length 20 m.
lower
- Motor suitable for operation with frequency converter.
Seal lubrication oil Oil for food/pharmaceutical machinery - Three-phase pumps with incorporated float switch.
30
12 40
H 8
m ft ft
10 H
m
GX 30 GX
C4 GX V4 20
6 GX V4
8 0-1 0
GX 3 V4 0-8 -9
C4 0-7
0-1
0
6 20
4
10
4
10 2
2
0 0 0 0
0 m 3/h 6 12 18 24 30 0 m3/h 6 12 18 24
Q Q
0 l/min 100 200 300 400 500 0 l/min 100 200 300 400
72.918-N
253
GXC, GXV Submersible Sewage and Drainage Pumps
P1 Max. power input. P2 Rated motor power output. Density ρ = 1000 kg/m3. Kinematic viscosity ν = max 20 mm2/sec.
On
100
h max
G1 1/2 Off
fM
ISO 228
h min
190
4.93.522
Ø 35
215
103
103
405
mm kg(1) mm kg(1)
TYPE TYPE
fM h max h min GXV GXVM fM h max h min GXC GXCM
GXV(M) 40-7 433 508 248 10,1 11,7 GXC(M) 40-10 433 508 248 10,1 11,7
GXV(M) 40-8 458 533 273 11,7 13,2 GXC(M) 40-13 458 533 273 11,7 13,2
GXV(M) 40-9 458 533 273 11,7 13,2
1) With cable length: 10 m
254
GXC, GXV Submersible Sewage and Drainage Pumps
Installation examples
On
Off G 1 1/2
ISO 228
3.93.037/3
215
3.93.037/3
min 550 x 550
Connection examples
Pump with hosetail seat and Pump with pipe screwed into Pump with pipe and union
clamp the delivery port (locally available)
(locally available)
255
GXC, GXV Submersible Sewage and Drainage Pumps
Features
PATENTED
GXC GXV
GXV The free-fow impeller (vortex)
GXC The two-passage impeller construction is particularly suitable
costruction is particulary suitable Shaft in chrome-nickel stainless for liquids with a high solid content
for liquids containing solids up to 35 steel. up to 35 mm grain size or with fila-
mm grain size. mentous particles.
256
03/2021
Construction
PATENTED Single-impeller submersible pumps, with free-flow (vortex) impeller
with vertical threaded delivery port.
Double mechanical shaft seal with interposed oil chamber, to
protect against dry-running.
Applications
For domestic or industrial waste water, dirty water with solids up
to 40 mm grain size, for liquids which are compatible with the
pump materials.
For draining rooms or or emptying tanks.
Extraction of water from ponds, streams or pits and for rainwater
collection.
Operating conditions
Liquid temperature up to 35° C.
pH value: 6-11.
Maximum immersion depth: 5 m.
Minimum immersion depth: 200 mm.
Continuous duty (with submerged motor).
Motor
2-pole induction motor, 50 Hz (n ≈ 2900 rpm).
GQS: three-phase 230 V ± 10%;
three-phase 400 V ± 10%;.
Cable: H07RN-F, 4G1 mm2, length 10 m, without plug.
GQSM: single-phase 230 V ± 10%,
with float switch and thermal protector.
Incorporated capacitor.
Materials Cable: H07RN-F, 3G1 mm2, length 10 m, with plug
Component Material CEI-UNEL 47166.
Insulation class F.
Pump casing Cast iron GJL 200 EN 1561
Protection IP X8 (for continuous immersion)
Impeller Double impregnation humidity-proof dry winding.
Motor jacket Chrome-nickel steel 1.4301 EN 10088 (AISI 304) Constructed in accordance with: EN 60034-1;
Jacket cover EN 60335-1, EN 60335-2-41.
9 30
GQ
8 S4
0-9 ft
H
m
6 20
3 10
0 0
0 m3/h 10 20
Q l/min
0 100 200 300
257
GQS 40 Submersible Sewage and Drainage Pumps
GQS 40-9 2,8 1,6 GQSM 40-9 4,5 20 450 0,95 0,45 0,6 Hm 9,3 8,8 8,3 7,3 6,3 5,2 3,8 2,3 0,9 - - - -
P1 Max. power input. P2 Rated motor power output. Density ρ = 1000 kg/m3. Kinematic viscosity ν = max 20 mm2/sec.
On
Installation examples
DN ISO 228
h max
l3
fM
Off
h min
a1
Øp
j5
l2l1
3.93.037/3
mm kg (1)
TYPE
DN a1 fM l1 l2 l3 j5 Øp j1 h max h min GQS GQSM
GQS(M) 40-9 G 11/2 120 385 78 81 110 222 40 410 460 200 10,5 10,5
1) With cable length: 10 m
258
03/2021
Construction
PATENTED Single-impeller submersible pumps, with free-flow (vortex) impeller.
GQS: with vertical threaded delivery port (G 2”).
GQV: with horizontal flanged and threaded delivery port
(DN 50 - G 2”).
Double mechanical shaft seal with interposed oil chamber, to
protect against dry-running.
Applications
For domestic or industrial waste water, dirty water with solids up
to 50 mm grain size, for liquids which are compatible with the
pump materials.
For draining rooms or or emptying tanks.
Extraction of water from ponds, streams or pits and for rainwater
collection.
Operating conditions
Liquid temperature up to 35° C.
pH value: 6-11.
Maximum immersion depth: 5 m.
Minimum immersion depth: 275 mm.
Continuous duty (with submerged motor).
Motor
2-pole induction motor, 50 Hz (n ≈ 2900 rpm).
GQV, GQS: three-phase 230 V ± 10%;
three-phase 400 V ± 10%;.
Cable: H07RN-F, 4G1 mm2, length 10 m, without plug.
GQVM, GQSM: single-phase 230 V ± 10%,
Materials with float switch and thermal protector.
Component Material Incorporated capacitor.
Pump casing Cable: H07RN-F, 3G1 mm2, length 10 m, with
Cast iron GJL 200 EN 1561 plug CEI-UNEL 47166.
Impeller
Insulation class F.
Motor jacket
Protection IP X8 (for continuous immersion)
Jacket cover Chrome-nickel steel 1.4301 EN 10088 (AISI 304)
Triple impregnation humidity-proof dry winding.
Casing cover Constructed in accordance with: EN 60034-1;
Handle Polypropylene (with frame in AISI 304) EN 60335-1, EN 60335-2-41.
Shaft Chrome-nickel steel 1.4301 EN 10088 (AISI 304)
Other features on request
Mechanical seal: upper - Other voltages. - Frequency 60 Hz (as per 60 Hz data sheet).
Ceramic alumina/Carbon/NBR
lower - Other mechanical seal. - Cable length 20 m.
- Motor suitable for operation with frequency converter.
Seal lubrication oil Oil for food/pharmaceutical machinery
- Three-phase pumps with incorporated float switch.
H
m 50
14 GQS, ft
GQV
50-15
GQS 40
12 , GQ
V 50-
13
GQS,
10 GQV
50-11
30
GQS
, GQ
8 V 50-
9
GQS
, GQ
V 50
6 -8 20
4
10
2
0 0
0 m3/h 10 20 30 36
0
Q l/min 100 200 300 400 500 600
259
GQS, GQV Submersible Sewage and Drainage Pumps
P1 Max. power input. P2 Rated motor power output. Density ρ = 1000 kg/m3. Kinematic viscosity ν = max 20 mm2/sec.
On On
Ø 165
Ø 125
G 2 ISO 228
Ø 90
130 Off 150 Off
G2
h max
h max
fM
G 2 ISO 228
fM
Ø 50
D N 50
h min
h min
145
90
Ø 50 M8 Ø 19 Ø 50
264 242
89
89
94
94
452 430
mm kg (1) mm kg (1)
TYPE TYPE
fM h max h min GQS GQSM fM h max h min GQV GQVM
GQS(M) 50-8 460 535 275 14,8 15,8 GQV(M) 50-8 460 535 275 15 16
GQS(M) 50-9 460 535 275 15 16 GQV(M) 50-9 460 535 275 15,2 16,2
GQS(M) 50-11 485 560 300 15,8 17,8 GQV(M) 50-11 485 560 300 16 18
GQS(M) 50-13 505 580 320 18,8 20,3 GQV(M) 50-13 505 580 320 19 20,5
GQS 50-15 505 580 320 20,3 - GQV 50-15 505 580 320 20,5 -
GQSM 50-15 535 610 350 - 21,8 GQVM 50-15 535 610 350 - 22
1) With cable length: 10 m 1) With cable length: 10 m
260
GQS, GQV Submersible Sewage and Drainage Pumps
Installation examples
500 min
284
12
86 190
52
On
3/4"
mm
TYPE
h h
max min
Off
h max
G2 ISO 228
45
134
430 max
380
138
16
89
360 min
132
100
38
94
110
166 Pump with threaded ports: Pump with threaded ports: Pump with DN 50 flanged ports:
pipes screwed into the ports pipes with union couplings pipes with counter-flanges
(locally available)
3/730.39.3
261
GQS, GQV Submersible Sewage and Drainage Pumps
Features
Cable length 10 m, pump single-phase Handle in polypropylene, with frame
with plug PATENTED
in stainless steel.
GQS
262
03/2021
Construction
PATENTED Single-impeller submersible pumps, (with two-passage) with
channels impeller with vertical threaded delivery port (G 2”).
Double mechanical shaft seal with interposed oil chamber, to
protect against dry-running.
Applications
For domestic or industrial waste water, dirty water with solids up
to 50 mm grain size, for liquids which are compatible with the
pump materials.
For draining rooms or or emptying tanks.
Extraction of water from ponds, streams or pits and for rainwater
collection.
Operating conditions
Liquid temperature up to 35° C.
pH value: 6-11.
Maximum immersion depth: 5 m.
Minimum immersion depth: 275 mm.
Continuous duty (with submerged motor).
Motor
2-pole induction motor, 50 Hz (n ≈ 2900 rpm).
GQN : three-phase 230 V ± 10%;
three-phase 400 V ± 10%;.
Cable: H07RN-F, 4G1 mm2, length 10 m, without plug.
GQNM: single-phase 230 V ± 10%,
with float switch and thermal protector.
Incorporated capacitor.
Materials Cable: H07RN-F, 3G1 mm2, length 10 m, with plug
Component Material CEI-UNEL 47166.
Pump casing Insulation class F.
Cast iron GJL 200 EN 1561 Protection IP X8 (for continuous immersion)
Impeller
Triple impregnation humidity-proof dry winding.
Motor jacket
Constructed in accordance with: EN 60034-1;
Jacket cover Chrome-nickel steel 1.4301 EN 10088 (AISI 304)
EN 60335-1, EN 60335-2-41.
Casing cover
Handle Polypropylene (with frame in AISI 304) Other features on request
- Other voltages.
Shaft Chrome-nickel steel 1.4301 EN 10088 (AISI 304)
- Frequency 60 Hz (as per 60 Hz data sheet).
Mechanical seal: upper - Other mechanical seal.
Ceramic alumina/Carbon/NBR
lower - Cable length 20 m.
- Motor suitable for operation with frequency converter.
Seal lubrication oil Oil for food/pharmaceutical machinery
- Three-phase pumps with incorporated float switch.
H
m 50
14 ft
GQ
N5 40
12 0-1
7
GQ
10 N5
0-1
5
30
GQ
8 N5
0-1
3
6 20
4
10
2
0 0
0 m3/h 10 20 30 40 50
0
Q l/min 200 300 400 500 600 700 800
263
GQN Submersible Sewage and Drainage Pumps
P1 Max. power input. P2 Rated motor power output. Density ρ = 1000 kg/m3. Kinematic viscosity ν = max 20 mm2/sec.
On
G 2 ISO 228
130 Off
h max
fM
h min
152,5
4.93.690
Ø 50
272
92
104
452
mm kg (1)
TYPE
fM h max h min GQN GQNM
GQN(M) 50-13 493 568 308 16 18
GQN(M) 50-15 513 588 328 19 20,5
GQN 50-17 513 588 328 20,5 -
GQNM 50-17 543 618 358 - 22
1) With cable length: 10 m
264
GQN Submersible Sewage and Drainage Pumps
Installation examples
3.93.037/3
3/730.39.3
265
GQN Submersible Sewage and Drainage Pumps
Features
PATENTED
268
03/2021
Construction
Close coupled electric submersible pumps.
GMC: with single-channel impeller.
GMV: with free-flow (vortex) impeller.
Double mechanical shaft seal with interposed oil chamber, to
protect against dry-running.
Applications
For domestic or industrial waste water, dirty water with solids up
to 45 mm grain size for GMC and 50 mm for GMV, for liquids
which are compatible with the pump materials.
Operating conditions
Liquid temperature up to 35 °C.
pH value: 6-11.
Maximum immersion depth: 10 m (with suitable cable length).
Continuous duty (with submerged motor).
Motor
2-pole induction, 50 Hz (n ≈ 2900 rpm).
GMC, GMV:
three-phase 230 V ± 10%;
three-phase 400 V ± 10%;
2 built-in thermal protectors to be connected
to a control box.
Cable: 4G1,5 mm2+ 2x0,5 mm2, length 10 m.
GMCM, GMVM: single-phase 230 V ± 10%.
With float switch, built-in thermal protector
Materials and built-in capacitor.
Component Material Cable: H07RN8-F, 3G1,5 mm2, length 10 m,
Pump casing with plug (CEI - UNEL 47166).
Casing cover Insulation class F.
Impeller Cast iron GJL 200 EN 1561 Protection IP X8.
Motor housing Triple impregnation, humidity-proof winding.
Motor cover Constructed in accordance with: EN 60335-2-41.
Shaft Chrome steel 1.4016 EN 10088 (AISI 430)
Mechanical seal: Upper Carbon, ceramic, NBR Other features on request
- Other voltages.
Lower Silicon carbide, silicon carbide, NBR
- Frequency 60 Hz (as per 60 Hz data sheet).
Seal lubrication oil Oil for food machinery and pharmaceutic use - Motor suitable for operation with frequency converter.
0 3
0 0 3
0
0 m /h 12 18 24 30 36 42 48 0 m /h 12 18 24 30 36 42
0
Q l/min 200 300 400 500 600 700 800 0
Q l/min 200 300 400 500 600 700
72.868.C
269
GMC, GMV Submersible Sewage and Drainage Pumps
3
3~ 230 V 400 V 1~ 230 V Capacitor P1 P2 m /h 0 6 12 18 24 30 36 42 48
Q
A A A Vc kW kW HP l/min 0 100 200 300 400 500 600 700 800
GMC 50CE GMCM 50CE
GMC 50-65C 3,3 1,9 GMCM 50-65C 4,5 16 450 1,1 0,75 1 12,8 9,5 8 6,5 5 3 1
GMC 50BE GMCM 50BE
GMC 50-65B 4,8 2,7 GMCM 50-65B 6,5 12,5x2 450 1,5 1,1 1,5 Hm 15,5 12,5 10 8,5 6,5 5 3 1
GMC 50AE
6,6 3,8 1,5 2 17,3 14,5 12,5 11 9 7,5 5,5 3 1
GMC 50-65A
3
3~ 230 V 400 V 1~ 230 V Capacitor P1 P2 m /h 0 6 12 18 24 30 31 35 39
Q
A A A Vc kW kW HP l/min 0 100 200 300 400 500 516 583 650
GMV 50CE GMVM 50CE
GMV 50-65C 3,3 1,9 GMVM 50-65C 4,5 16 450 1,1 0,75 1 9,2 8 7 5 3,5 1,5 1
GMV 50BE GMVM 50BE
GMV 50-65B 4,8 2,7 GMVM 50-65B 6,5 12,5x2 450 1,5 1,1 1,5 Hm 10,7 9,5 8 6,5 4,5 2,5 2,3 1
GMV 50AE
GMV 50-65A 6,6 3,8 1,5 2 12,9 11,5 10 8,5 6,5 4,3 4 2,5 1
P1 Max. power input. H Total head in m. Density ρ = 1000 kg/m3. Kinematic viscosity ν = max 20 mm2/sec.
P2 Rated motor power output.
185
505
145
500
90 ISO 228 G 2
DN 65
400
395
185
155
180
100
4.93.107
kg
kg
GMV 50CE 27
GMV 50-65C 29
GMV 50BE 28
GMV 50-65B 30
GMV 50AE 29,5
GMV 50-65A 31,5 304 315
530 max
GMVM 50CE 27
530 max
GMVM 50-65C 29
GMVM 50BE 28,5
GMVM 50-65B 30,5
kg
118
kg
GMC 50CE 28
GMC 50-65C 30
248
GMC 50BE 29
GMC 50-65B 31
GMC 50AE 30,5
GMC 50-65A 32,5
130
GMCM 50CE 28
GMCM 50-65C 30
GMCM 50BE 29,5
GMCM 50-65B 31,5
270
GMC, GMV Submersible Sewage and Drainage Pumps
78
13
33
500 min 600 min
12 346 443
83
52 86 223 85 319
100
2"
3/4"
180 117
DN 65
G2 ISO 228
EN 1092-2
575
540
80 22 PN 10
253
255
220
176
134
34
68
200
16
92 92
132
100
198
120
110
166
18
440 531
138 180
530 max
530 max
118
118
360 min
360 min
185
145
38
18
130
130
271
GMC, GMV Submersible Sewage and Drainage Pumps
Features
GMV GMC
Safety
The double mechanical seal with oil chamber ensures safe separation separa-
ting the motor from water and providing further protection against accidental
operation when dry.
Reliable
The lower double ball bearing ensures high reliability under all operating condi-
tions.
Protection
The three-phase motors are equipped with integrated thermistors, which provi-
de the motor with thermal protection. The motor cable is pre-wired to enable the
user to connect directly to a control panel, providing easier installation.
Flexible installation
The availability of the pump casing with horizontal or vertical flanged ports allows
the installation of pumps in all pits and wells, both small and large sizes.
Installation is also possible with a duck foot coupling.
272
03/2021
Construction
PATENTED Submersible pumps with high power grinder, with horizontal
flanged and threaded delivery port (DN 32 PN 6 - G 1 1/2).
Double mechanical shaft seal with interposed oil chamber, to
protect against dry-running.
Applications
Suitable for pumping waste water containing long filamentous,
paper and textile materials and organics.
They are particularly suitable for use in domestic, residential and
industrial installations.
Solid passage Ø 6 mm
Operating conditions
Liquid temperature up to 35° C.
Maximum immersion depth: 5 m.
Minimum immersion depth: 300 mm.
Continuous duty (with submerged motor).
Motor
2-pole induction motor, 50 Hz (n ≈ 2900 rpm).
GQG: three-phase 230 V ± 10%;
three-phase 400 V ± 10%;.
GQGM:single-phase 230 V ± 10%,
with float switch, thermal protection and control box with
starting capacitors.
Materials Cable: H07RN8-F, 4G1 mm2 (4G1,5 mm2 for GMGM 6-25),
Component Material length 10 m.
Insulation class F.
Pump casing
Impeller Cast iron GJL 200 EN 1561 Protection IP X8 (for continuous immersion)
Casing cover Triple impregnation humidity-proof dry winding.
Rotating cutting blade Constructed in accordance with: EN 60034-1;
Nickel-Molybdenum steel 1.4125 EN 10088 (AISI 440C) EN 60335-1, EN 60335-2-41.
Fixed cutting blade
Motor jacket
Chrome-nickel steel 1.4301 EN 10088 (AISI 304)
Jacket cover Other features on request
Handle Polypropylene (with frame in AISI 304) - Other voltages.
Shaft Chrome-nickel steel 1.4305 EN 10088 (AISI 303)
- Frequency 60 Hz.
- Other mechanical seal.
Mechanical seal: upper
lower
Ceramic alumina/Carbon/NBR - Cable length 20 m.
- Vertical magnetic float switch.
Seal lubrication oil Oil for food/pharmaceutical machinery - Three-phase pumps with incorporated float switch.
90
GQG
80
6-25
70
20 6-21
60
H 6-18
m 50
ft
40
10
30
20
10
0 0
0 m3/h 5 10 15 18
Q l/min
0 50 100 150 200 250 300
273
GQG Submersible pumps with high power grinder
P1 Max. power input. P2 Rated motor power output. Density ρ = 1000 kg/m . 3
Kinematic viscosity ν = max 20 mm /sec. 2
On
560 max
485
Off
300 min
16
65
4.93.436
GQGM
Control with box starting capacitors
216 111
kg
TYPE
GQG GQGM
219
made in italy
274
GQG Submersible pumps with high power grinder
Installation example
500 min
12 313
86 218
52
On
3/4"
G2 ISO 228
80 22
Off
628 max
368 min
68.5
176
134
4.93.436/2
430 max
393
138
16
98.5 91.5
360 min
132
100
38
110
166
275
GQG Submersible pumps with high power grinder
Features
PATENTED
Cable length 10 m.
Handle in polypropylene, with frame in
stainless steel.
Pump casing and casing cover with epoxy Cutting system made of HRC 60 hardness AISI 440C
cataphoresis treatment joined to the external stainless steel.
paint for a greater protection against the rust.
276
03/2021
GM
Submersible Pumps
277
GM Submersible Pumps
GMV
Submersible pumps with vortex impeller in cast iron EN-GJL-250 pag. 280
GMVS
Submersible pumps with vortex impeller in cast iron with polyurethane coating pag. 287
GMC
Submersible pumps with single channel impeller in cast iron EN-GJL-250 pag. 289
GMN
Submersible pumps with channels impeller in cast iron EN-GJL-250 pag. 298
GMG
I-GMV
Submersible pumps with vortex impeller in stainless steel AISI316 pag. 316
I-GMC
Submersible pumps with single channel impeller in stainless steel AISI316 pag. 316
I-GMN
Submersible pumps with channels impeller in stainless steel AISI316 pag. 316
B-GMV
Submersible pumps with vortex impeller in Marine Bronze B10 pag. 327
B-GMC
Submersible pumps with single channel impeller in Marine Bronze B10 pag. 327
B-GMN
Submersible pumps with channels impeller in Marine Bronze B10 pag. 327
278
GM Submersible Pumps
Coverage chart
80
70
60
H
m
GMC
50
40
GMV GMN
30
20
GMC4
10
GMV4
0
72.2000
5 Q m 3/h 10 20 30 40 50 100 200 500 1000 2000 3000
279
Submersible pumps
GMV with vortex impeller
Construction
Submersible pumps with vortex impeller.
Twin mechanical seal with oil chamber.
Delivery connection DN 80-100-150.
Applications
Suitable to pump slurry and sewage waters with the presence of
solid and filamentous parts in suspension, they are in particular
pointed out for emptying sceptic tanks in the domestic, residen-
tial and industrial installations.
Solid passage diameter from 50 to 100 mm.
Operating conditions
Liquid temperature up to 40 °C.
Maximum immersion depth: 20 m (with suitable cable length).
Continuous duty (with pump immerged at minimum level).
Motor
2 or 4 poles induction, 50Hz
Main materials Three-phase version: 400V ± 10%
Pump casing: cast iron EN-GJL-250 400/690V ± 10%
Impeller: cast iron EN-GJL-250+Ni
Insulation Class: H
Motor casing: cast iron EN-GJL-250
Protection degree: IP 68
Motor cover: cast iron EN-GJL-250
N° of starting x hour: max 15 with regular intervals
Shaft: stainless steel AISI 420B
Cable: H07RN-F, length 10 m
Mechanical seal motor side: graphite/ceramic
Other models: contact our sale office
Mechanical seal pump side: silicon carbite/silicon carbite
Classification scheme IE3.
Coverage chart
100
50
GMV
40 GMV 50-80
30
GMV 80-80
20
H
m GMV4
GMV4 90-100 100-150
10
GMV4
80-100
5 GMV4 65-80
4
3
72.2001
2
5 Q m3/h 10 15 20 30 40 50 100 150 200 300 400 500
280
Submersible pumps
GMV with vortex impeller
Technical data
P2 Rated power output IN Rated current Standard ATEX Eex Version on demand
281
Submersible pumps
GMV with vortex impeller
Characteristic curves
0 U.S. g.p.m. 150 200 250 300 350 400 0 U.S. g.p.m. 150 200 250 300 350 400
0 Imp. g.p.m. 100 150 200 250 300 350 0 Imp. g.p.m. 100 150 200 250 300 350
25 50
80
160
GMV 50-80 GMV 50-80
20 C n ≈ 2850 1/min 45 n ≈ 2850 1/min
60 A
140
D B
15 ft 40 ft
H E H
m 40 m
120
10 F 35
20
100
5 30
0 0 25
0 m 3/h 20 40 60 80 100 0 m 3/h 20 40 60 80 100
0 Q l/min 500 1000 1500 0 Q l/min 500 1000 1500
40 50
η% B
30
η% 30 A
20 C
E D 20
10 10
F
0 0
8 20
6 15
A B
P2 C P2
4 D 10
kW E kW
2 F 5
0 0
0 m 3/h 20 40 60 80 100 0 m 3/h 20 40 60 80 100
0 Q l/min 500 1000 1500 0 Q l/min 500 1000 1500
72.2007 72.2008
0 U.S. g.p.m. 200 300 400 500 600 0 U.S. g.p.m. 150 200 250 300 350 400
0 Imp. g.p.m. 200 300 400 500 0 Imp. g.p.m. 100 150 200 250 300 350
15 30
C
20 40
D
5 10
0 0 0 0
0 m3/h 50 100 150 0 m 3/h 20 40 60 80 100
0 Q l/min 1000 2000 0 Q l/min 500 1000 1500
60 60
50 50
η% η%
30 30
A
20
B A 20
10 C 10 B
D
0 0
6 14
5 12
P2 P2
kW A kW A
3 B 8
2 C 6 B
1
D 4
0 2
0 m3/h 50 100 150 0 m 3/h 20 40 60 80 100
0 Q l/min 1000 2000 0 Q l/min 500 1000 1500
72.2009 72.2009
282
Submersible pumps
GMV with vortex impeller
Characteristic curves
0 U.S. g.p.m. 200 300 400 500 600 0 U.S. g.p.m. 300 400 500 600 700 800
0 Imp. g.p.m. 200 300 400 500 0 Imp. g.p.m. 200 300 400 500 600 700
50 20
160
60
GMV 80-80 GMV4 90-100
40 n ≈ 2850 1/min n ≈ 1450 1/min
S 120 15 ft
A
A H
30 ft m B 40
H B
m 80 10
20
20
40 5
10
0 0 0 0
0 m3/h 50 100 150 0 m3/h 50 100 150 200
0 Q l/min 1000 2000 0 Q l/min 1000 2000 3000
40 60
30 S
η% 40
20 B A η% A
10 20
B
0 0
25 9
S 8
20 P2 A
P2 A 6
15 B
kW kW
B 4
10
3
5 2
0 m3/h 50 100 150 0 m3/h 50 100 150 200
0 Q l/min 1000 2000 0 Q l/min 1000 2000 3000
72.2010 72.2011
0 U.S. g.p.m. 500 1000 0 U.S. g.p.m. 600 800 1000 1200 1400 1600
0 Imp. g.p.m. 500 1000 0 Imp. g.p.m. 400 600 800 1000 1200 1400
25 40
80
S
GMV4 80-100 GMV4 100-150 120
n ≈ 1450 1/min n ≈ 1450 1/min
20
A 30 ft
60
B H
15 ft m 80
H C
m 40 20
10
40
20 10 E
5
0 0 0 0
0 Q m 3/h 50 100 150 200 250 300 0 m3/h 100 200 300 400
0 l/min 1000 2000 3000 4000 5000 0 Q l/min 2000 4000 6000
80 50
E
60 40
η% η%
40
A S
B 20
20 C
10
0 0
32 35
30
24 S P2
P2 E
kW
16 A 15
kW 10
8 B
C 5
0 0
0 Q m 3/h 50 100 150 200 250 300 0 m3/h 100 200 300 400
0 l/min 1000 2000 3000 4000 5000 0 Q l/min 2000 4000 6000
72.2012 72.2013
283
Submersible pumps
GMV with vortex impeller
83
85 d3
GMV4 65-80
33
Ø 52
100
2“
180 116
DN 80
PN 10
fM
370
DN2
256
HL
200
hf
a
210
160
18 160
d4
110 131
Ø 75
l1
l2 412 min
g2
n3
Version with foot and 90° elbow Version with duck foot coupling
GMV4 90-100 78
13
GMV4 80-100
83
d1 min.
33
Ø 52 d2
100 85 d3
2“
190 116
fM DN 100
PN 10
HL
DN2
220
a
400
hf
266
GMV4 GMV4 HL minimum submersible level
DN1
90-100 80-100 h2 h1
250
100 100 20
210
210
160
160
18
d4
131
140
Ø 100
l1
550 min
l2
g2
n3
Version with foot and 90° elbow Version with duck foot coupling
EN 1092-2 Dimensions
Dimensioni - Dimensions Peso
TIPO
TYPE
TYPE PN 10 mmmm Weight
DN1 DN2 fM HL hf a l1 l2 d1 d2 d3 d4 h1 h2 n3 g2 kg
GMV4 90-100B/A
125 100 829 490 89 111 180 180 800 633 443 933 241 277 500 150 165
GMV4 90-100A/A
GMV4 80-100C/A
GMV4 80-100B/A 125 100 921 570 54 147 189 212 800 640 445 940 195 279 500 150 205
GMV4 80-100A/A
GMV4 80-100S/A 125 100 1343 670 54 146 193 212 800 640 441 936 200 280 500 150 325
285
Submersible pumps
GMV with vortex impeller
GMV4 100-150 78
13
83
d1 min.
33
Ø 52 d2
100 85 d3
2“
222 116
DN 150
PN 10
fM
DN2
HL 538
285
a 383
300
100 100 20
250
200
200
250
18
d4
131
205
Ø 150
l1
740 min
l2
g2
600
Version with foot and 90° elbow Version with duck foot coupling
EN 1092-2 Dimensions
Dimensioni - Dimensions Peso
TIPO
TYPE PN 10 mm mm Weight
TYPE
DN1 DN2 fM HL hf a l1 l2 d1 d2 d3 d4 h1 h2 n3 g2 kg
GMV4 100-150E/A 150 150 1359 710 114 146 193 223 850 675 469 1040 206 280 600 225 355
286
Submersible pumps vortex
GMVS with polyurethane coated hydraulic parts
Construction
Submersible pumps with vortex impeller
Impeller in Polyurethane with a stainless steel core - Pump
casing in Cast iron EN-GJL-250, with polyurethane coating for
parts subject to high wear.
Twin mechanical seal with oil chamber.
Delivery connection DN 80.
Applications
The pumps are designed to suit applications in plants with an
high sand presence, in marble work companies, in the ceramic
industry, crystals machining or industrial processes handling
abrasives liquids.
Solid passage diameter from 35 mm.
Operating conditions
Liquid temperature up to 40 °C.
Maximum immersion depth: 20 m (with suitable cable length).
Continuous duty (with pump immerged at minimum level).
Motor
2 or 4 poles induction, 50Hz
Main materials Three-phase version: 400/690V ± 10%
Pump casing: cast iron EN-GJL-250 with polyurethane coating Insulation Class: H
Impeller: Polyurethane with a stainless steel core Protection degree: IP 68
Motor casing: cast iron EN-GJL-250 N° of starting x hour: max 15 with regular intervals
Motor cover: cast iron EN-GJL-250 Cable: H07RN-F, length 10 m
Shaft: stainless steel AISI 420B Other models: contact our sale office
Mechanical seal motor side: graphite/ceramic Classification scheme IE3.
Mechanical seal pump side: silicon carbite/silicon carbite
Coverage chart
70
60 GMVS 35-80A
50 GMVS 35-80B GMVS
GMVS 35-80C
40 GMVS 35-80D
GMVS 35-80E
GMVS 35-80F
30
GMVS 35-80G
GMVS 35-80H
20
H
m GMVS4 35-80A
10
3
3 4 5 Q m 3/h 10 20 50 100 150 200
287
Submersible pumps vortex
GMVS with polyurethane coated hydraulic parts
Technical data
13 2“
78
fM
83
HL
33
a DN 80
PN 10
DN1
h2 h1
370
hf
256
250
100 100 20 d4
110
131
Ø 75
210
210
160
160
18
l1
400 min
l2
g2
n3
288
Submersible pumps
GMC with single channel impeller
Construction
Submersible pumps with single channel impeller.
Twin mechanical seal with oil chamber (lip-seal motor side up to
1,4 kW).
Delivery connection DN 50-65-80-100-150
Applications
Suitable to pump slurry, sewage, waste water (non-corrosive).
In industrial and residential installations and drainag applications
Solid passage from 40 to 100mm
Operating conditions
Liquid temperature up to 40 °C.
Maximum immersion depth: 20 m (with suitable cable length).
Continuous duty (with pump immerged at minimum level).
Motor
2 or 4 poles induction, 50Hz
Main materials Single-phase version: 230V ± 10%, with float switch and built-in
Pump casing: cast iron EN-GJL-250 - Impeller: cast iron EN-GJL-250+Ni capacitor.
Motor casing, Motor cover: cast iron EN-GJL-250 Three-phase version: 400V ± 10%,
Motor shaft: stainless steel AISI 420B 400/690V ± 10%
Lip seal made of nitrile up to 1,4 kW Insulation class: H
Mechanical seal motor side: graphite/ceramic over 1,4 kW Protection degree: IP 68
Mechanical seal pump side: silicon carbite/silicon carbite N° of starting x hour: max 15 with regular intervals
Cable: H07RN-F, length 10 m
Other models: contact our sale office
Classification scheme IE3.
Coverage chart
100
50
GMC
40
30 GMC 40-80
20
H GMC4 90-100
m
GMC4 80-100
10 GMC4
100-150
2
5 Q m3/h 10 15 20 30 40 50 100 150 200 300 400 500
289
Submersible pumps
GMC with single channel impeller
Technical data
P2 Rated power output IN Rated current Standard ATEX Eex Version on demand
290
Submersible pumps
GMC with single channel impeller
Characteristic curves
0 U.S. g.p.m. 50 100 150 200 0 U.S. g.p.m. 100 300 200 250
0 Imp. g.p.m. 50 100 150 0 Imp. g.p.m. 100 150 200
30 30
B 1~
20 20
0 0 0 0
0 Q m 3/h 10 20 30 40 50 0 Q m 3/h 10 20 30 40 50 60
0 l/min 250 500 750 0 l/min 250 500 750 1000
60 60
η 50
40 η A
% 30
20
A % B 1~
B 3~
10
B 1~ B 3~
0 0
1,5 3
A
B 3~ P2 A
1,0 B 1~ 2
kW B 3~
P2 B 1~
0,5 1
kW
0 0
0 Q m 3/h 10 20 30 40 50 0 Q m 3/h 10 20 30 40 50 60
0 l/min 250 500 750 0 l/min 250 500 750 1000
72.2014 72.2015
GMC 40-80
60 A n ≈ 2850 1/min 200
B
H
m C 150
40 ft
100
20
50
0 0
0 Q m 3/h 20 40 60 80 100
0 l/min 500 1000 1500
60
η B
40 C
%
A
20
0
20
A B
15
P2 C
10
kW
5
0 Q m 3/h 20 40 60 80 100
0 l/min 500 1000 1500
72.2014
291
Submersible pumps
GMC with single channel impeller
Characteristic curves
0 U.S. g.p.m. 200 300 400 500 0 U.S. g.p.m. 400 600 800 1000
0 Imp. g.p.m. 200 300 400 0 Imp. g.p.m. 400 600 800
15 20
0 0 0 0
0 Q m 3/h 20 40 60 80 100 120 0 m3/h 200 250
0 l/min 500 1000 1500 2000 Q l/min 50 100 150
0 1000 2000 3000 4000
70 80
60 η
75-8
50 0A %
η 65- A
80C 40 C
30
%
20
B
10
0 0
4 6
3
5 A
P2 75-80A P2
2 3
C B
kW 65-80C kW
1
1
0 0
0 Q m 3/h 20 40 60 80 100 120 0 m3/h 200 250
l/min Q l/min 50 100 150
0 500 1000 1500 2000 0 1000 2000 3000 4000
72.2015 72.2016
0 U.S. g.p.m. 400 600 800 1000 1200 0 U.S. g.p.m. 500 1000 1500 2000
0 Imp. g.p.m. 400 600 800 1000 0 Imp. g.p.m. 500 1000 1500
30 35
ft
H GMC4 90-100 GMC4 100-150 100
30 n ≈ 1450 1/min
m n ≈ 1450 1/min 80
ft
H A
m 80
20
A 60 B
20
B 60
15 C
15
40
40
10
10
20 20
5 5
0 0 0 0
0 m3/h 100 200 300 0 m3/h 100 200 300 400 500
Q l/min 0 Q l/min 2000 4000 6000 8000
0 1000 2000 3000 4000 5000
80 80
η η
% %
40 A 40
A
20
B 20 C
B
0 0
12 20
10 16 A
P2 A P2
kW
B B
kW
6 8 C
4 4
2 0
0 m3/h 100 200 300 0 m3/h 100 200 300 400 500
0
Q l/min
1000 2000 3000 4000 5000 0 Q l/min 2000 4000 6000 8000
72.2017 72.2018
292
Submersible pumps
GMC with single channel impeller
GMC 30-50
450 min.
52
12 307
86 189
3/4“
75 28
HL G 2”
475
Ø 50
268
176
134
64
71
110
156
392
116
106 106
400 min
2“
2“
90
136
16
Version with threaded flange and 90° elbow Version with duck foot coupling
TIPO Peso
TYPE
TYPE Weight
kg
GMCM 30-50B
GMC 30-50B 31
GMC 30-50A
293
Submersible pumps
GMC with single channel impeller
GMC 40-65
13
78 600 min
85 447
83
317
33
Ø 52
100
2“
180 117
DN 65
EN 1092-2
HL PN 10
556
Ø 60
335
253
47
121
18
720
181
124
Ø 69
130 130
360 min.
2“ 1/2
2“
1/
15
2
90
96
15
Version with threaded flange and 90° elbow Version with duck foot coupling
TIPO Peso
TYPE Weight
TYPE
kg
GMCM 40-65B
GMC 40-65B 45
GMC 40-65A
294
Submersible pumps
GMC with single channel impeller
GMC 40-80 13
d1 min.
78
GMC4M 65-80 d2
83
GMC4 65-80 85 d3
33
Ø 52
GMC4 75-80
100
2“
180 116
DN 80
PN 10
200
GMC
fM
40-80 DN2 370
HL 256
200
hf
a
210
160
160
18
d4
131
110
Ø 75
l1
412 min
l2
g2
n3
Version with foot and 90° elbow Version with duck foot coupling
EN 1092-2 Dimensions
Dimensioni - Dimensions Peso
TIPO
TYPE PN 10 mmmm Weight
TYPE
DN1 DN2 fM HL hf a l1 l2 d1 d2 d3 d4 h1 h2 n3 g2 kg
GMC 40-80C/A
GMC 40-80B/A 80 80 890 523 85 116 168 168 750 603 416 883 187 250 500 150 195
GMC 40-80A/A
GMC4M 65-80C/A 80 80 533 330 104 100 132 132 658 498 366 775 132 200 364 140 49
GMC4 65-80C/A
GMC4 75-80A/A 80 80 516 380 80 121 143 169 700 548 396 828 152 250 364 140 67
295
Submersible pumps
GMC with single channel impeller
GMC4 80-100 78
13
GMC4 90-100
83
d1 min.
33
Ø 52 d2
100 85 d3
2“
190 116
fM DN 100
PN 10
HL
DN2
220
a
400
hf
266
HL minimum submersible level
GMC4 GMC4 DN1
80-100B 80-100A h2 h1
90-100B
90-100A
250
100 100 20
210
210
160
160
18
d4
131
140
Ø 100
l1
550 min
l2
g2
n3
Version with foot and 90° elbow Version with duck foot coupling
296
Submersible pumps
GMC with single channel impeller
GMC4 100-150 78
13
83
d1 min.
33
Ø 52 d2
100 85 d3
2“
222 116
DN 150
PN 10
fM
DN2
HL 538
285
383
a
200
250
18
d4
131
205
Ø 150
l1
740 min
l2
g2
n3
Version with foot and 90° elbow Version with duck foot coupling
297
Submersible pumps
GMN with channels impeller
Construction
Submersible pumps with channels impeller.
Twin mechanical seal with oil chamber.
Delivery connection DN 65-80-100-150-200-250-300.
Applications
Suitable to pump slurry, sewage and waste water (non-corrosive)
with solids in suspension.
For industrial and residential installations and general drainage
applications.
They are ideal for applications with smaller solids.
Solid passage from 30 to 140 mm
Operating conditions
Liquid temperature up to 40 °C.
Maximum immersion depth: 20 m (with suitable cable length).
Continuous duty (with pump immerged at minimum level).
Motor
Main materials 2-4-6 or 8 poles induction, 50Hz
Pump casing: cast iron EN-GJL-250 Three-phase version: 400V ± 10%,
Impeller: cast iron EN-GJL-250+Ni 400/690V ± 10%
Motor casing: cast iron EN-GJL-250 Insulation class: H
Motor cover: cast iron EN-GJL-250 Protection degree: IP 68
Shaft: stainless steel AISI 420B N° of starting x hour: max 15 with regular intervals
Mechanical seal motor side: graphite/ceramic Cable: H07RN-F, length 10 m
Mechanical seal pump side: silicon carbide/silicon carbide Other models: contact our sale office
Classification scheme IE3.
Coverage chart
100
50
GMN
40 GMN 40-100
30
GMN4 100-250
20
GMN 30-80
GMN4 80-150
H GMN4 GMN4
m 100-150 100-200
10
GMN4 80-100
GMN6
100-250
GMN 30-65 GMN6
100-200
5
4
GMN8
3 GMN8 100-250 GMN8 140-300 GMN6 140-300
GMN6 80-100 GMN6 80-150 100-200
72.2003
2
10 Q m3/h 20 30 40 50 100 150 200 300 400 500 1000 1500 2000 3000
298
Submersible pumps
GMN with channels impeller
Technical data
P2 Rated power output IN Rated current Standard ATEX Eex Version on demand
299
Submersible pumps
GMN with channels impeller
Characteristic curves
0 U.S. g.p.m. 200 300 400 0 U.S. g.p.m. 200 300 400 500 600
0 Imp. g.p.m. 100 200 300 0 Imp. g.p.m.100 200 300 400 500
20 40
60 120
A GMN 30-65 GMN 30-80
n ≈ 2850 1/min n ≈ 2850 1/min
H
30 S
m
B ft
H
40 m A 80
10 20 B
20 40
10
0 0 0 0
0 m3/h 20 40 60 80 100 0 m3/h 50 100 140
0 Q l/min 500 1000 1500 Q l/min
0 1000 2000
80 80
A A
60 60
η% B η% S
20
B
20
0 0
4 8
P2 A S
6
kW B P2
A
2 B
kW
1 2
0 0
0 m3/h 20 40 60 80 100 0 m3/h 50 100 140
0 Q l/min 500 1000 1500 Q l/min
0 1000 2000
72.2019 72.2020
H
m 80
20
40
10
0 0
0 m3/h 50 100 150 200 250
0 Q l/min 1000 2000 3000 4000
80
η%
S
40
D B
20 C
0
20
P2 S
kW
C B
10 D
5
0
0 m3/h 50 100 150 200 250
0 Q l/min 1000 2000 3000 4000
72.2021
300
Submersible pumps
GMN with channels impeller
Characteristic curves
0 U.S. g.p.m. 400 600 800 0 U.S. g.p.m. 800 1200
0 Imp. g.p.m. 200 400 600 0 Imp. g.p.m. 400 800
10
30
GMN6 80-100 20 GMN4 80-100
n ≈ 950 1/min n ≈ 1450 1/min
H H 60
A
m m A
ft
B 20
ft
C
5 40
10
D
10
20
0 0 0 0
0 m 3/h 50 100 150 200 0 m /h
3
100 200 300
0 Q l/min 1000 2000 3000 0 Q l/min 2000 4000
80 80
60 60 A
η% η % D C
A
20 B 20
0 0
3 10
A
A 8
2 B P2 C
P2 kW
kW D
4
1
2
0 0
0 m 3/h 50 100 150 200 0 m /h
3
100 200 300
0 Q l/min 1000 2000 3000 0 Q l/min 2000 4000
72.2023 72.2024
0 U.S. g.p.m. 400 800 1200 1600 0 U.S. g.p.m. 800 1200 1600 2000 2400
0 Imp. g.p.m. 400 800 1200 0 Imp. g.p.m.
400 800 1200 1600 2000
15 50
160
H
m C 80
20 20
5
40
10 10
0 0 0 0
0 m3/h 100 200 300 400 0 Q m3/h 100 200 300 400 500 600
0 Q l/min 2000 4000 6000 0 l/min 2000 4000 6000 8000 10000
80 80
60 A η%
η% B 40
C B
20 20
0 0
10 40
8 P2
A kW B
P2
kW 20 C
4 B
2 10
0 0
0 m3/h 100 200 300 400 0 Q m3/h 100 200 300 400 500 600
0 Q l/min 2000 4000 6000 0 l/min 2000 4000 6000 8000 10000
72.2025 72.2026
301
Submersible pumps
GMN with channels impeller
Characteristic curves
0 U.S. g.p.m. 800 1200 1600 2000 0 U.S. g.p.m. 800 1200 1600 2000 2400
0 Imp. g.p.m. 400 800 1200 1600 400
0 Imp. g.p.m. 800 1200 1600 2000
25 40
80
GMN6 100-150 S
GMN4 100-150 120
40
20 10 E
5
0 0 0 0
0 m3/h 100 200 300 400 500 0 Q m3/h 100 200 300 400 500 600
0 Q l/min 2000 4000 6000 8000 0 l/min 2000 4000 6000 8000 10000
80 80
S
η% η%
A
40 40 E F
G D
20 B 20
0 0
16 40
P2 A P2 S
kW kW
E F D
8 B 20
G
4 10
0 0
0 m /h
3
100 200 300 400 500 0 Q m3/h 100 200 300 400 500 600
0 Q l/min 2000 4000 6000 8000 0 l/min 2000 4000 6000 8000 10000
72.2027 72.2028
302
Submersible pumps
GMN with channels impeller
Characteristic curves
0 U.S. g.p.m. 1000 1500 2000 2500 0 U.S. g.p.m. 1600 2400 3200
0 Imp. g.p.m. 500 1000 1500 2000 0 Imp. g.p.m. 800 1600 2400
15 20
60
H GMN8 100-200 GMN6 100-200
m n ≈ 750 1/min 40 n ≈ 950 1/min
H
m
D ft
10
ft 40
A E
B 10
20
5
20
0 0 0 0
0 m3/h 200 300 400 500 600 0 m3/h 200 400 600 800
Q l/min 0 Q l/min 4000 8000 12000
0 5000 10000
100 100
80 80
A 60 D
60
% η%
η B
20 20
0
E
0
10 14
A D
12
8
B P2 E
P2 kW
kW 8
4 6
2 4
0 m3/h 200 300 400 500 600 0 m3/h 200 400 600 800
Q l/min 0 Q l/min 4000 8000 12000
0 5000 10000
72.2029 72.2030
0 U.S. g.p.m. 1600 2400 3200 4000 0 U.S. g.p.m. 2000 3000 4000 5000
0 Imp. g.p.m. 800 1600 2400 3200 0 Imp. g.p.m. 1000 2000 3000 4000
40 15
A
GMN4 100-200 120
H GMN8 100-250
n ≈ 1450 1/min m 40
B n ≈ 750 1/min
30 ft A
C 10
H
m 80 ft
20
B
20
5
40
10
0 0 0 0
0 m3/h 200 400 600 800 1000 0 m 3/h 500 1000
Q l/min 0 Q l/min 10000 20000
0 4000 8000 12000 16000
80 100
80
η%
60 A
40
C A η% B
B
20 20
0 0
50 20
40
A
B 16 A
P2
kW C P2
20 kW
B
10 8
0 4
0 m3/h 200 400 600 800 1000 0 m 3/h 500 1000
0 Q l/min 4000 8000 12000 16000 Q l/min
0 10000 20000
72.2028 72.2031
303
Submersible pumps
GMN with channels impeller
Characteristic curves
0 U.S. g.p.m. 2000 3000 4000 5000 0 U.S. g.p.m. 800 1200 1600 2000
0 Imp. g.p.m. 1000 2000 3000 4000 0 Imp. g.p.m. 400 800 1200 1600
30 50
160
C H
m 80
D 40 20
10
40
10
0 0 0 0
0 m 3/h 500 1000 0 m3/h 500 1000 1500
0 Q l/min 10000 20000 Q l/min 5000
0 10000 15000 20000 25000
100 100
80
A
80
A
60 η%
η% 40
B
D C
20 D 20
C B
0 0
40 100
A B P2
30
C kW A
P2 B
kW D 60
C
10 40 D
0 20
0 m 3/h 500 1000 0 m3/h 500 1000 1500
0 Q l/min 10000 20000 0 Q l/min 5000 10000 15000 20000 25000
72.2032 72.2033
0 U.S. g.p.m. 1600 2400 3200 0 U.S. g.p.m. 4000 6000 8000 10000
0 Imp. g.p.m. 800 1600 2400 0 Imp. g.p.m. 2000 4000 6000 8000
20 30
60
GMN8 140-300 H GMN6 140-300
n ≈ 750 1/min m n ≈ 950 1/min 80
H A
m
ft 20
A B
40 ft
C
10
D
40
10
20
0 0 0 0
0 m3/h 400 800 1200 1600 0 m 3/h 1000 2000
0 Q l/min 8000 16000 24000 0 Q l/min 10000 20000 30000 40000
100 100
80 A 80
A
60 60
% η% D B
C
20 20
0 0
30 60
A
A 50
P2 P2
20 kW B
kW
30
C
10 20 D
0 m3/h 400 800 1200 1600 0 m 3/h 1000 2000
0 Q l/min 8000 16000 24000 Q l/min 10000
0 20000 30000 40000
72.2030 72.2034
304
Submersible pumps
GMN with channels impeller
GMN 30-65 78
13
d1 min.
83
85 d2
33
d3
Ø 52
100
2“
180 117
DN 65
PN 10
fM
DN2
253
216
HL
185
hf
a
h2 h1 200
92 92
120
198
18
d4
100 180
Ø 62
360 min
l1
l2
g2
n3
Version with foot and 90° elbow Version with duck foot coupling
EN 1092-2 Dimensions
Dimensioni - Dimensions Peso
TIPO
TYPE PN 10 mm mm Weight
TYPE
DN1 DN2 fM HL hf a l1 l2 d1 d2 d3 d4 h1 h2 n3 g2 kg
GMN 30-65B/A
80 65 456 300 78 90 133 145 625 495 357 767 138 220 364 140 62
GMN 30-65A/A
305
Submersible pumps
GMN with channels impeller
GMN 30-80 78
13
d1 min.
d2
83
85 d3
33
Ø 52
100
2“
180 116
DN 80
PN 10
fM
370
DN2
256
HL
200
hf
a
HL minimum submersible level
DN1
h2 h1 250
100 100 20
210
210
160
160
18
d4
131
110
Ø 75
l1
412 min
l2
g2
n3
Version with foot and 90° elbow Version with duck foot coupling
EN 1092-2 Dimensions
Dimensioni - Dimensions Peso
TIPO
TYPE PN 10 mm mm Weight
TYPE
DN1 DN2 fM HL hf a l1 l2 d1 d2 d3 d4 h1 h2 n3 g2 kg
GMN 30-80B/A
80 80 515 330 110 90 133 145 700 511 366 791 145 220 370 140 75
GMN 30-80A/A
GMN 30-80S/A 100 80 767 438 132 68 165 165 700 571 386 851 185 220 500 150 150
306
Submersible pumps
GMN with channels impeller
13
78
GMN 40-100
83
d1 min.
GMN 50-100
33
d2
GMN4 80-100 Ø 52
d3
85
GMN6 80-100 100
2“
220
190 116
a
400
250
100 100 20
210
210
160
160
18
d4
140
131
Ø 100
l1
550 min
l2
g2
n3
Version with foot and 90° elbow Version with duck foot coupling
EN 1092-2 Dimensions
Dimensioni - Dimensions Peso
TIPO
TYPE PN 10 mm mm Weight
TYPE
DN1 DN2 fM HL hf a l1 l2 d1 d2 d3 d4 h1 h2 n3 g2 kg
GMN 40-100D/A
GMN 40-100C/A 125 100 794 480 127 73 168 184 750 628 441 928 187 275 500 150 206
GMN 40-100B/A
GMN 40-100S/A 125 100 1269 570 127 73 193 193 800 628 441 928 187 275 500 150 340
GMN4 80-100D/A 125 100 597 424 62 138 180 231 850 673 466 973 207 300 500 150 115
GMN4 80-100C/A 125 100 852 526 54 147 189 212 800 640 445 940 195 279 500 150 175
GMN4 80-100A/A 125 100 920 570 54 147 189 212 800 640 445 940 195 279 500 150 205
GMN6 80-100B/A 125 100 531 372 62 138 180 231 850 673 466 973 207 300 500 150
96
GMN6 80-100A/A 597 424 114
307
Submersible pumps
GMN with channels impeller
13
GMN6 80-150 78
GMN6 100-150
83
d1 min.
33
GMN4 80-150 Ø 52 d2
85 d3
GMN4 100-150 100
2“
222 116
DN 150
PN 10
fM
DN2
HL
285
538
383
a
200
250
18
205 d4
131
Ø 150
l1
740 min
l2
g2
n3
Version with foot and 90° elbow Version with duck foot coupling
EN 1092-2 Dimensions
Dimensioni - Dimensions Peso
TIPO
TYPE PN 10 mmmm Weight
TYPE
DN1 DN2 fM HL hf a l1 l2 d1 d2 d3 d4 h1 h2 n3 g2 kg
GMN6 80-150B/A 820 540 190
150 150 113 147 191 223 850 673 467 1038 206 301 600 225
GMN6 80-150A/A 933 580 220
GMN6 100-150B/B 150 150 1274 737 80 180 239 304 990 840 566 1208 273 400 500 225 382
GMN6 100-150A/B
GMN4 80-150C/B 150 150 1409 737 80 180 239 304 990 840 566 1208 273 400 500 225 450
GMN4 80-150B/B 150 150 1439 742 80 180 239 304 990 840 566 1208 273 400 500 225 515
GMN4 100-150G/A
GMN4 100-150F/A 150 150 1409 737 80 180 239 304 990 840 566 1208 273 400 500 225 430
GMN4 100-150E/B
GMN4 100-150D/B 150 150 1439 742 80 180 239 304 990 840 566 1208 273 400 500 225 518
GMN4 100-150S/B
308
Submersible pumps
GMN with channels impeller
13
GMN4 100-200 78
GMN6 100-200 d1 min.
83
GMN8 100-200 d2
33
Ø 52
85 d3
100
2“
337 116
DN 200
fM PN 10
DN2 HL
700
340
461
a
HL minimum submersible level hf
DN1
h2 h1
400
133 133 20
300
250
250
300
20
d4
110
l1
800 min
l2
g2
n3
EN 1092-2 Dimensions
Dimensioni - Dimensions Peso
TIPO
TYPE PN 10 mmmm Weight
TYPE
DN1 DN2 fM HL hf a l1 l2 d1 d2 d3 d4 h1 h2 n3 g2 kg
GMN4 100-200C/A
GMN4 100-200B/A 200 200 1613 780 153 198 306 335 1200 962 656 1469 306 480 700 265 665
GMN4 100-200A/A
GMN6 100-200E/B
200 200 1256 665 153 180 269 336 1200 958 656 1467 303 480 700 265 385
GMN6 100-200D/B
GMN8 100-200B/C 200 200 1392 665 153 180 269 335 1200 958 656 1467 303 480 700 265 435
GMN8 100-200A/A
309
Submersible pumps
GMN with channels impeller
30
GMN4 100-250
d1 min.
GMN6 100-250
d2
GMN8 100-250 200
120 d3
2“
275 112
DN 250
fM PN 10
DN2 HL
695
395
a 435
HL minimum submersible level
DN1
hf
h2 h1
22
Ø
320
365 74
584
d4
122
l1
1000 min
l2
g2
n3
EN 1092-2 Dimensions
Dimensioni - Dimensions Peso
TIPOTYPE
PN 10 mm mm Weight
TYPE
DN1 DN2 fM HL hf a l1 l2 d1 d2 d3 d4 h1 h2 n3 g2 kg
GMN4 100-250D
GMN4 100-250C 250 250 1710 797 250 214 336 419 1400 1130 752 1602 378 600 700 265 914
GMN4 100-250B
GMN4 100-250A
GMN6 100-250D 1408 530
250 250 735 250 180 336 419 1400 1130 752 1602 378 600 700 265
GMN6 100-250C 1437 590
GMN6 100-250B 250 250 1629 800 286 214 336 419 1400 1130 752 1602 378 600 700 265 750
GMN6 100-250A
GMN8 100-250B/A 250 250 1408 735 250 180 336 419 1400 1130 752 1602 378 600 700 265
520
GMN8 100-250A/B 1437 600
310
Submersible pumps
GMN with channels impeller
103
11 11
GMN6 140-300
d1 min.
19
d2
120 d3
125
3“
437 119
DN 300
PN 10
fM
DN2
HL
445
827
665
a
650
30
500
500
795
d4
113
l1
1000 min
l2
g2
n3
EN 1092-2 Dimensions
Dimensioni - Dimensions Peso
TIPO
TYPE PN 10 mm mm Weight
TYPE
DN1 DN2 fM HL hf a l1 l2 d1 d2 d3 d4 h1 h2 n3 g2 kg
GMN6 140-300D
GMN6 140-300C 350 300 1959 1127 260 494 465 465 1500 1254 789 1930 465 600 1248 540 1030
GMN6 140-300B 350 300 2040 1164 260 494 465 465 1500 1254 789 1930 465 600 1248 540 1190
GMN6 140-300A
GMN8 140-300A 350 300 1959 1127 260 494 465 465 1500 1254 789 1930 465 600 1248 540 1024
311
Submersible pumps
GMG with high power grinder
Construction
Submersible pumps with high power grinder.
Twin mechanical seal with oil chamber (lip-seal motor side up
to 1,6 kW).
Delivery connection DN 40.
Applications
Suitable for pumping waste water containing long filamentous,
Paper and textile materials and organics.
They are particularly suitable for use in domestic, residential and
industrial installations
Solid passage from 6 and 7 mm
Operating conditions
Liquid temperature up to 40 °C.
Maximum immersion depth: 20 m (with suitable cable length).
Continuous duty (with pump immerged at minimum level).
Motor
2 poles induction, 50Hz
Main materials Single-phase version: 230V ± 10%, with float switch and control
Pump casing: cast iron EN-GJL-250 box with thermal protection and starting capacitors.
Motor casing: cast iron EN-GJL-250 Three-phase version: 400V ± 10%,
Motor cover: cast iron EN-GJL-250 400/690V ± 10%
Impeller: cast iron EN-GJS-400 Insulation class: H
Shaft : stainless steel AISI 420B Protection degree: IP 68
Lip seal made of nitrile up to 1,6 kW N° of starting x hour: max 15 with regular intervals
Mechanical seal motor side: graphite/ceramic over 1,6 kW Cable: H07RN-F, length 10 m
Mechanical seal pump side: silicon carbide/silicon carbide Other models: contact our sale office
Classification scheme IE3.
Coverage chart
0 U.S. g.p.m. 20 30 40 50 60 70 80
50
160
GMG 7-40A
GMG 7-40B
GMG
40
GMG 7-40D
30 ft
GMG 7-40E
H
m GMG-GMGM 6-40A 80
20 GMG-GMGM 6-40B
GMGM 6-40C
40
GMGM 6-40D
10
GMGM 6-40E
0 0
0 m 3/h 5 10 15 20
0 Q l/min 100 200 300
72.2004
312
Submersible pumps
GMG with high power grinder
Technical data
313
Submersible pumps
GMG with high power grinder
Characteristic curves
0 U.S. g.p.m. 30 40 50 60 70 0 U.S. g.p.m. 30 40 50 60 70
H
GMGM 6-40 A GMG 7-40
m
A n ≈ 2850 1/min 80 n ≈ 2850 1/min 140
40
B
ft
20 B H C 120
ft m
C D
30 100
E
40
D 80
10
E 20
60
40
0 0 10
0 m3/h 5 10 15 0 m3/h 5 10 15
0 Q l/min 0 Q l/min 100 200
100 200
50 40
B E
40 C 30 D
A
η% C
η%
20 B
D 10
A
10
E
0 0
2,0 5
A A
P2 4 B
kW P2 C
B kW
1,0 C D
2
D E
0,5 E 1
0 0
0 m /h
3
5 10 15 0 m3/h 5 10 15
0 Q l/min 0 Q l/min 100 200
100 200
72.2035 72.2036
314
Submersible pumps
GMG with high power grinder
3/4“
fM
Ø 40 75
HL
28
a G 2”
h2 h1 HL minimum submersible level
176
134
hf
d4
116
400 min
l1
100
1“
2“
1 /2
l2
90
110
136 R6
16
Version with threaded flange and 90° elbow Version with duck foot coupling
Dimensions
Dimensioni - Dimensions Peso
TIPO
TYPE mm
mm Weight
TYPE
Ø1 fM HL hf a l1 l2 d1 d2 d3 d4 h1 h2 kg
GMGM 6-40E/B
40 487 246 65 103 122 122 450 297 178 392 118 135 30
GMGM 6-40D/B
GMGM 6-40C/A
GMGM 6-40B/A
GMG 6-40B/A 40 464 316 72 63 112 112 450 312 194 392 118 150 40
GMGM 6-40A/A
GMG 6-40A/A
GMG 7-40E/A
40 451 325 17 117 121 121 450 327 189 413 138 150 52
GMG 7-40D/A
GMG 7-40C/A
GMG 7-40B/A 40 510 353 17 117 121 121 450 334 189 420 147 150 67
GMG 7-40A/A
195
To fix the control panel, use the preposed holes
as specify in this drawing.
In order to maintain the protection degree,
suitable fixing devices must be used.
315
I-GM Submersible pumps AISI 316
Construction
Submersible pumps in AISI 316 stainless steel.
I-GMV with free-flow (vortex) impeller
I-GMC with single-channel impeller
I-GMN with channels impeller
Twin mechanical seal with oil chamber (lip-seal motor side up to
2,4 kW 2 poles).
Delivery connection DN 50-65-80-100-150
Applications
Suitable to pump aggressive and corrosive liquids, particularly
to drain waste water in industrial and chemical process plants.
Solid passage from 30 to 100 mm
Operating conditions
Liquid temperature up to 40 °C.
Maximum immersion depth: 20 m (with suitable cable length).
Continuous duty (with pump immerged at minimum level).
Coverage chart
100
50
I-GM
40
30
I-GMN
20
H
m
I-GMC
10
5
I-GMV
4
3
72.2006
2
2 Q m3/h 5 10 15 20 30 40 50 100 150 200 300 400 500
316
I-GM Submersible pumps AISI 316
Technical data
317
I-GM Submersible pumps AISI 316
Characteristic curves
0 U.S. g.p.m. 50 100 150 0 U.S. g.p.m. 80 120 160 200 240
0 Imp. g.p.m. 50 100 0 Imp. g.p.m. 80 120 160 200
15 10
30
9
I-GMV 50-50 I-GMV4 50-65
40 8 n ≈ 1450 1/min
n ≈ 2850 1/min A 25
A H ft
10 m
B B
30 6 20
H
m C
C ft 5
15
20 4 ft
5
10
3
10 2
5
1
0 0 0 0
0 Q m3/h 10 20 30 40 0 m3/h 40 50 60
0 l/min 100 200 300 400 500 600 Q l/min 10 20 30
0 200 400 600 800 1000
50 50
40 40
η% A η%
20 20 A
10 10 B
C B C
0 0
2
A 1,2 A
1,5 B
P2 B P2
1
C 0,8
kW C
kW
0,5 0,4
0 0
0 Q m3/h 10 20 30 40 0 m3/h 40 50 60
Q l/min 10 20 30
0 l/min 100 200 300 400 500 600 0 200 400 600 800 1000
72.2037 72.2038
0 U.S. g.p.m. 100 200 300 400 0 U.S. g.p.m. 80 120 160 200 240
0 Imp. g.p.m. 100 200 300 0 Imp. g.p.m. 80 120 160 200
10 20
30 60
9
I-GMV4 50-80 I-GMC 40-65
8
A n ≈ 1450 1/min n ≈ 2850 1/min
ft 15 50
H B ft
m A
6 20 H 40
m B
5 10
30
4 ft
3 10 20
5
2
10
1
0 0 0 0
0 Q m3/h 60 80 100 0 m3/h 40 50 60
0 l/min
20
500
40
1000 1500 Q l/min 10 20 30
0 200 400 600 800 1000
60 60
40 40
η% A η% A
20 B 20
B
0 0
3 3
A P2 A
P2
2 2
kW kW
B
B
1 1
0 0
0 Q m3/h 60 80 100 0 m3/h 40 50 60
0 l/min
20
500
40
1000 1500 Q l/min 10 20 30
0 200 400 600 800 1000
72.2039 72.2040
318
I-GM Submersible pumps AISI 316
Characteristic curves
0 U.S. g.p.m. 100 200 300 400 0 U.S. g.p.m. 200 300 400 500 600
0 Imp. g.p.m. 100 200 300 0 Imp. g.p.m.100 200 300 400 500
20 40
60 120
I-GMN 30-65 I-GMN 30-80
A n ≈ 2850 1/min n ≈ 2850 1/min
15 ft 30 ft
S
H
B
H
m 40 m 80
A
10 20
20 40
5 10
0 0 0 0
0 Q m3/h 20 40 60 80 100 0 Q m3 /h 20 40 60 80 100 120 140
0 l/min 500 1000 1500 0 l/min 500 1000 1500 2000
80 80
A
60 60 S
η% η%
40 40 A
B
20 B 20
0 0
4 8
P2 A P2 S
3 6 A
kW B kW
2 4 B
1 2
0 Q m3/h 20 40 60 80 100 0 Q m3 /h 20 40 60 80 100 120 140
0 l/min 500 1000 1500 0 l/min 500 1000 1500 2000
72.2041 72.2042
0 U.S. g.p.m. 400 600 800 1000 0 U.S. g.p.m. 400 600 800 1000
0 Imp. g.p.m. 200 400 600 800 0 Imp. g.p.m. 200 400 600 800
50 80
160
C 200
30 ft 60 B
H D H
m 80 m
C
20 50
160
40 ft
10 40
120
0 0 30
0 Q m3/h 50 100 150 200 250 0 Q m 3/h 50 100 150 200 250
0 l/min 1000 2000 3000 4000 0 l/min 1000 2000 3000 4000
80 80
60 60
η% S η%
40 40
D B
20 20
C
0 0
20 60
S A
P2 P2
15 B 40 B
kW C kW
C
10 D 20
5 0
0 Q m3/h 50 100 150 200 250 0 Q m 3/h 50 100 150 200 250
0 l/min 1000 2000 3000 4000 0 l/min 1000 2000 3000 4000
72.2043 72.2044
319
I-GM Submersible pumps AISI 316
Characteristic curves
0 U.S. g.p.m. 400 600 800 1000 0 U.S. g.p.m. 400 600 800 1000 1200
0 Imp. g.p.m. 200 400 600 800 0 Imp. g.p.m. 400 600 800 1000 1200
20 25
80
I-GMN4 60-100 60
I-GMN4 80-100
n ≈ 1450 1/min n ≈ 1450 1/min
B A 20
15 ft
60
A
H
m 40 15 ft
H B
10 m 40
10
20
5 20
5
0 0 0 0
0 Q m3/h 50 100 150 200 250 0 Q m 3/h 100 200 300 340
0 l/min 1000 2000 3000 4000 0 l/min 1000 2000 3000 4000 5000
80 80
60 A 60 A
η% η%
40 40 B
20
B 20
0 0
8 12
P2 P2
A
6
A 8
kW kW B
4
B 4
2 0
0 Q m3/h 50 100 150 200 250 0 Q m /h 100 200 300 340
0 l/min 1000 2000 3000 4000 0 l/min 1000 2000 3000 4000 5000
72.2045 72.2046
A I-GMN4 100-150
25 n ≈ 1450 1/min 80
B
20
H 60
m
15 ft
40
10
20
5
0 0
0 Q m 3/h 100 200 300 400 500
0 l/min 2000 4000 6000 8000
80
60 A
η%
40
B
20
0
30
P2 A
20
kW B
10
0
0 Q m 3/h 100 200 300 400 500
0 l/min 2000 4000 6000 8000
72.2047
320
I-GM Submersible pumps AISI 316
Dimensions and weights
I-GMV 50-50
450 min.
52 312
12 86 194
3/4“
HL
555
Ø 50
330
75 28
125
G 2”
HL minimum submersible level
Ø 55
176
150 118
134
13
132
100
110
156
392
137
112 112
400 min
Ø 50
2“
90
136
16
Version with threaded flange and 90° elbow Version with duck foot coupling
TIPO Peso
TYPE Weight
TYPE
kg
I-GMV 50-50C/A
I-GMV 50-50B/B 46
I-GMV 50-50A/B
321
I-GM Submersible pumps AISI 316
Dimensions and weights
I-GMV4 50-65
I-GMC 40-65
13
78 600 min
85 447
83
33
317
Ø 52
100
2“
80 117
G 2 1/2"
HL
47
168
567
Ø 60
335
121
170
600min.
141
Ø 63
2“
130 130
360 min.
1/
15
2
5
10
110
15
Version with threaded flange and 90° elbow Version with duck foot coupling
TIPO Peso
TYPE Weight
TYPE
kg
I-GMV4 50-65C/A
I-GMV4 50-65B/A 47
I-GMV4 50-65A/A
I-GMC 40-65B/A 49
I-GMC 40-65A/A
322
I-GM Submersible pumps AISI 316
Dimensions and weights
13
I-GMN 30-65 78
625 min.
83
85 495
33
357
Ø 52
100
2“
80 117
HL G 2 1/2"
DN 65
456
EN 1092-2
300
PN 10
168
78
90
170
153 625min.
Ø 63 133
360 min.
145
140
364
Version with foot and 90° elbow Version with duck foot coupling
TIPO Peso
TYPE Weight
TYPE
kg
I-GMN 30-65B/A
62
I-GMN 30-65A/A
323
I-GM Submersible pumps AISI 316
Dimensions and weights
I-GMV4 50-80 13
78 d1 min.
I-GMN 30-80 d2
83
85 d3
33
Ø 52
100
2“
180 116
DN 80
EN 1092-2
PN 10
fM
370
DN 80
EN 1092-2
256
PN 10 HL
200
hf
a
210
160
160
18
d4
179 131
Ø 80
l1
412 min
l2
g2
n3
Version with foot and 90° elbow Version with duck foot coupling
324
I-GM Submersible pumps AISI 316
Dimensions and weights
I-GMN 40-100 78
13
I-GMN4 60-100
83
d1 min.
I-GMN4 80-100
33
Ø 52 d2
85 d3
100
2“
190 116
fM
HL DN2
DN2
220
a
400
250
100 100 20
210
210
160
160
18
d4
231
131
Ø 100
l1
550 min
l2
g2
n3
Version with foot and 90° elbow Version with duck foot coupling
325
I-GM Submersible pumps AISI 316
Dimensions and weights
I-GMN4 100-150 78
13
83
d1 min.
33
Ø 52 d2
85 d3
100
2“
222 116
DN2
fM
DN2
HL
538
285
383
a
300
100 100 20
250
200
200
250
18
d4
131
l1
740 min
l2
g2
n3
EN 1092-2 Dimensions
Dimensioni - Dimensions Peso
TIPO
TYPE PN 10 mm mm Weight
TYPE
DN1 DN2 fM HL hf a l1 l2 d1 d2 d3 d4 h1 h2 n3 g2 kg
GMN4 100-150B/A 150 150 991 576 100 160 235 305 990 931 566 1208 280 400 600 225 370
GMN4 100-150A/A 1055 600 405
326
B-GM Submersible pumps B 10
Construction
Submersible pumps, B 10 bronze marine version.
B-GMV with free-flow (vortex) impeller
B-GMC with single-channel impeller
B-GMN with channels impeller
Twin mechanical seal with oil chamber (lip-seal motor side up to
2,4 kW 2 poles).
Delivery connection DN 50-65-80
Applications
Suitable to pump industrial waste water in chemical, and process
industries, agricultural and marine areas.
Solid passage from 30 to 50 mm
Operating conditions
Liquid temperature up to 40 °C.
Maximum immersion depth: 20 m (with suitable cable length).
Continuous duty (with pump immerged at minimum level).
Motor
Main materials 2 or 4 poles induction, 50Hz
Pump casing, Motor casing, Motor cover: B 10 bronze marine Three-phase version: 400V ± 10%,
Impeller: stainless steel AISI 316 400/690V ± 10%
Motor shaft: stainless steel AISI 316L Insulation class: H
Screws: stainless steel AISI 316 Protection degree: IP 68
Mechanical seal motor side: graphite/ceramic/FPM (lip-seal made of nitrile up to N° of starting x hour: max 15 with regular intervals
2,4 kW 2 poles). Cable: H07RN-F, length 10 m
Mechanical seal pump side: silicon carbide/silicon carbide/FPM Other models: contact our sale office
Classification scheme IE3.
Coverage chart
30
B-GM
20
H
m
B-GMN
B-GMC
10
5
B-GMV
4
3
72.2005
2
2 Q m3/h 5 10 15 20 30 40 50 100 120
327
B-GM Submersible pumps B 10
Technical data
328
B-GM Submersible pumps B 10
Characteristic curves
0 U.S. g.p.m. 50 100 150 0 U.S. g.p.m. 80 120 160 200 240
0 Imp. g.p.m. 50 100 0 Imp. g.p.m. 80 120 160 200
15 10
30
9
B-GMV 50-50 B-GMV4 50-65
40 8 n ≈ 1450 1/min
n ≈ 2850 1/min A 25
A H ft
10 m
B B
30 6 20
H
m C
C ft 5
15
20 4 ft
5
10
3
10 2
5
1
0 0 0 0
0 Q m3/h 10 20 30 40 0 m3/h 40 50 60
0 l/min 100 200 300 400 500 600 Q l/min 10 20 30
0 200 400 600 800 1000
50 50
40 40
η% A η%
20 20 A
10 10 B
C B C
0 0
2
A 1,2 A
1,5 B
P2 B P2
1
C 0,8
kW C
kW
0,5 0,4
0 0
0 Q m3/h 10 20 30 40 0 m3/h 40 50 60
Q l/min 10 20 30
0 l/min 100 200 300 400 500 600 0 200 400 600 800 1000
72.2037 72.2038
0 U.S. g.p.m. 100 200 300 400 0 U.S. g.p.m. 80 120 160 200 240
0 Imp. g.p.m. 100 200 300 0 Imp. g.p.m. 80 120 160 200
10 20
30 60
9
B-GMV4 50-80 B-GMC 40-65
8
A n ≈ 1450 1/min n ≈ 2850 1/min
ft 15 50
H B ft
m A
6 20 H 40
m B
5 10
30
4 ft
3 10 20
5
2
10
1
0 0 0 0
0 Q m3/h 20 40 60 80 100 0 m3/h
Q l/min 10 20 30 40 50 60
0 l/min 500 1000 1500 0 200 400 600 800 1000
60 60
40 40
η% A η% A
20 B 20
B
0 0
3 3
A P2 A
P2
2 2
kW kW
B
B
1 1
0 0
0 Q m3/h 20 40 60 80 100 0 m3/h
Q l/min 10 20 30 40 50 60
0 l/min 500 1000 1500 0 200 400 600 800 1000
72.2039 72.2040
329
B-GM Submersible pumps B 10
Characteristic curves
0 U.S. g.p.m. 100 200 300 400 0 U.S. g.p.m. 200 300 400 500 600
0 Imp. g.p.m. 100 200 300 0 Imp. g.p.m.100 200 300 400 500
20 30
60
B-GMN 30-65 B-GMN 30-80
A n ≈ 2850 1/min n ≈ 2850 1/min 80
15 ft
B 20
A
H ft
m 40
H
B
10
m
40
10
20
5
0 0 0 0
0 Q m3/h 20 40 60 80 100 0 Q m3 /h 20 40 60 80 100 120 140
0 l/min 500 1000 1500 0 l/min 500 1000 1500 2000
80 80
A
60 60
η% η%
40 40 A
B
20 B 20
0 0
4 6
A
P2 A P2
3 4 B
kW B kW
2 2
1 0
0 Q m3/h 20 40 60 80 100 0 Q m3 /h 20 40 60 80 100 120 140
0 l/min 500 1000 1500 0 l/min 500 1000 1500 2000
72.2041 72.2042
330
B-GM Submersible pumps B 10
Dimensions and weights
B-GMV 50-50
450 min.
52 312
12 86 194
3/4“
HL
544
Ø 50
330
75 28
125
G 2”
HL minimum submersible level
Ø 55
176
150 118
134
13
132
100
110
156
392
137
112 112
400 min
Ø 50
2“
90
136
16
Version with threaded flange and 90° elbow Version with duck foot coupling
TIPO Peso
TYPE Weight
TYPE
kg
B-GMV 50-50C/A
B-GMV 50-50B/B 48
B-GMV 50-50A/B
331
B-GM Submersible pumps B 10
Dimensions and weights
B-GMV4 50-65
B-GMC 40-65
13
78 600 min
83
85 447
33
Ø 52 317
100
2“
80 117
G 2 1/2"
HL
47
168
567
Ø 60
335
121
170
600min.
141
Ø 63
2“
130 130
360 min.
1/
15
2
5
10
110
15
Version with threaded flange and 90° elbow Version with duck foot coupling
TIPO Peso
TYPETYPE Weight
kg
B-GMV4 50-65C/A
B-GMV4 50-65B/A 48
B-GMV4 50-65A/A
B-GMC 40-65B/A 50
B-GMC 40-65A/A
332
B-GM Submersible pumps B 10
Dimensions and weights
B-GMN 30-65 78
13
625 min.
83
85 495
33
357
Ø 52
100
2“
80 117
HL G 2 1/2"
DN 65
456
EN 1092-2
300
PN 10
168
78
90
170
153 625min.
Ø 63 133
360 min.
145
140
364
Version with foot and 90° elbow Version with duck foot coupling
TIPO Peso
TYPE Weight
TYPE
kg
B-GMN 30-65B/A
65
B-GMN 30-65A/A
333
B-GM Submersible pumps B 10
Dimensions and weights
13
B-GMV4 50-80 78 d1 min.
B-GMN 30-80 d2
83
85 d3
33
Ø 52
100
2“
180 116
DN 80
EN 1092-2
PN 10
fM
370
DN 80
EN 1092-2 HL
256
PN 10
200
hf
a
HL minimum submersible level
DN 80
EN 1092-2
PN 10 250
h2 h1 100 100 20
210
210
160
160
18
d4
179 131
Ø 80
l1
412 min
l2
g2
n3
Version with foot and 90° elbow Version with duck foot coupling
334
GM Submersible Pumps
Features
335
GM Submersible Pumps
336
GM Submersible pumps
6 5
Allarme
Alarm
Marcia 2
Activation 2
1 Submersible pump
4
6 Gate valve
2
7 Level floats
8 Control box
337
GM Submersible pumps
Accessories
Non-return ball valves
Construction
Non-return self-cleaning ball valves, suitable for dirty and viscous liquids, sewage water.
Operating conditions
Working temperature from -10°C up to +80°C
Rated pressure: 10 bar
Vertical or horizontal installation
Materials
Valve body: Cast iron EN-GJL-250
Cover: Cast iron EN-GJL-250
Ball: Resin for threaded VNRP
Resin + nitril for VNRP DN 50-100
Cast iron + nitril for VNRP DN 125-250
Screws: SS AISI 304
Joint: nitril
Dimensions
B
B
DN E
DN D
A A
C
C
338
03/2021
Construction
This macerating pumping system has been designed to pump
away the waste water from a WC and a washbasin.
It is possibile to use it to add a new cloakroom, washroom or
toilet, in a basement or loft conversion or anywhere
conventional large bore pipework is impractical.
The GEOTRIT macerating system is installed in a case
specifically designed for horizontal outlet spigots.
Installed and used correctly, this unit will give consistent and
reliable service.
The system has a grinder pump, clapet valve and carbon filter.
GEOTRIT is provided with flexible sleeves, elbow, metal hose
clips.
Operating conditions
Voltage: 220-240 V
Frequency: 50 Hz
Degree of protection: IP44
Maximum power rating: 400 W
Maximum current consumption: 1,9 A
Vertical pumping: max. 4 m
Liquid temperature up to 35 °C
Application
GEOTRIT takes waste from :
WC Washbasin
Characteristic curve
0 U.S. g.p.m. 5 10 15 20 25
0 Imp. g.p.m. 5 10 15 20
10 32
GEOTRIT
28
8
24
H
6 ft
H
m 16
4
12
8
2 m3/h 0 1,2 2,4 3,6 4,8 5,4
4
Q
l/min 0 20 40 60 80 90
339
GEOTRIT Macerating pumping system
Installation
4.93.486
Performance
1%
4 m max max 10 m
3m max 20 m
Ø 28/32/40
mm
2m max 30 m 1%
Ø 22/28/32 mm
1m max 40 m
3%
DN 40
mm
4.93.481
318,5
317
258
184,7
183
4.93.483
peso: kg 6,6
427 235
340
GEOCOMP Macerating pumping system
Construction
This macerating pumping system has been designed to pump
away the waste water from WC, washbasin, bidet and shower.
It is possible to install a complete bathroom in a basement
conversion or loft extension.
The GEOCOMP macerating system is installed in a case
specifically designed for horizontal outlet spigots.
Installed and used correctly, this unit will give consistent and
reliable service.
The system has a grinder pump, clapet valve and carbon filter.
GEOCOMP is provided with flexible sleeves, elbow, metal hose
clips.
Operating conditions
Voltage: 220-240 V
Frequency: 50 Hz
Degree of protection: IP44
Maximum power rating: 400 W
Maximum current consumption: 1,9 A
Vertical pumping: max. 4 m
Liquid temperature up to 35 °C
Application
GEOCOMP takes waste from :
Characteristic curve
0 U.S. g.p.m. 5 10 15 20 25
0 Imp. g.p.m. 5 10 15 20
10 32
GEOCOMP 28
8
24
H
6 ft
H
m 16
4
12
8
2 m3/h 0 1,2 2,4 3,6 4,8 5,4
4
Q
l/min 0 20 40 60 80 90
341
GEOCOMP Macerating pumping system
Installation
4.93.485
Performance
1%
4 m max max 10 m
3m max 20 m
2m max 30 m
1m max 40 m
4.93.481
318,5
317
258
184,7
166
183
41,5
weight:
peso: kgkg 6,6
6,8
4.93.482
427,5 235
342
GEOCLEAN Lifting station for clear water
Construction
The system is design to handle the evacuation water from a
domestic kitchen sink, dishwasher and washing machine – all
working at the same time if required.
GEOCLEAN makes the addition of a domestic kitchen or utility
room easy even when below or distant from a drain.
The system has a clapet valve and it cannot be used with waste
waters.
GEOCLEAN is provided with flexible sleeves, elbow, metal hose
clips, plugs.
Operating conditions
Voltage: 220-240 V
Frequency: 50 Hz
Degree of protection: IP44
Maximum power rating: 400 W
Maximum current consuption: 1,9 A
Vertical pumping: max. 5 m
Liquid temperature up to 60 °C
Application
GEOCLEAN takes waste from :
Characteristic curve
0 U.S. g.p.m. 5 10 15 20 25
0 Imp. g.p.m. 5 10 15 20
10 32
GEOCLEAN
28
8
24
H
6 ft
H
m 16
4
12
8
2 m3/h 0 1,2 2,4 3,6 4,8 5,6
4
Q
l/min 0 20 40 60 80 93
343
GEOCLEAN Lifting station for clear water
Installation Performance
1%
5 m max max 5 m
4m max 10 m
3m max 20 m
2m max 30 m
1m max 40 m
4.93.484
4.93.479
4.93.484
318,5
317
258
41,5
weight: kg 6,4
4.93.480
peso: kg 6,4
427,5 112
344
03/2021
Construction
Medium-density polyethylene tank, resistant to corrosion,
GEO 40 with minimum overall dimensions.
- GEO 230 single tank with 230 liters nominal capacity for the
installation of an electropump type GM 10, GQ, GX or GM
series.
GEO 230
- GEO 500 double tank with 500 liters nominal capacity for the
installation of two electropumps type GM 10, GQ, GX or GM
series.
Applications
Automatic waste water collecting and lifting stations, to handle
domestic, civil and industrial waste water.
For collecting and lifting clean waste water and rain water.
For flood drainage.
Designation
GEO 40-GXRM 9
GEO 500 Series
Nominal tank capacity
Pump type
Installation examples
GEO 40-GXR GEO 230-GX.. GEO 500-2GM..
345
GEO 40 Automatic clear water collecting
and lifting station
Pumps characteristics
GEO 40-GXRM GEO 40-GXRM GF
Features
Automatic collecting and lifting station for clean water with GXRM pump
type .
It includes:
1 tank capacity 40 l
1 single-phase pump with 5 m cable and float switch
1 non-return valve with clapet on the pump delivery side
1 discharge pipe kit arranged for the connection of a Ø 40 mm PVC pipe
1 PVC adapting nipple for Ø 40 mm inlet
1 connector for Ø 25 mm flexible pipe
On demand
1 pump with 10 m cable
412
390 350
GXRM
Submersible drainage pump in chrome-nickel stainless steel, for clean water containing
solids up to 10 mm grain size, with vertical delivery port.
Open impeller.
2-pole induction motor, 50Hz (n ≈ 2900 rpm),
Single-phase 230 V +/-10% with float switch and thermal protector.
- GXRM: with standard float switch.
- GXRM .. GF: with vertical magnetic float switch.
Incorporated capacitor.
Cable length 5 m, Shuko plug.
GXRM GF
GXRM Liquid temperature up to 35 °C
14
GXRM
12
GX
RM
10 13
GX
RM
11
H
m GX
RM
9
6
0
0 m3/h 5 10 15
Q
0 l/min 50 100 150 200 250
346
GEO 230 Automatic clear water collecting
and lifting station
Pumps characteristics
GEO 230-GM 10
Features
Automatic clear water collecting and lifting station GM 10 pump series.
It includes:
1 tank capacity 230 l
1 single-phase pump with 5 m cable and float switch
1 control box QM 6,3 type with capacitor
1 discharge pipe kit Ø 40 mm in PVC
On demand
1 pump with 10 m cable
1 discharge pipe kit Ø 40 mm in PVC with a ball valve and non-return ball
valve
1 support kit with safety float switch and auto-supplied control panel for
remote alarm with horn and flashing light
- extention 300 mm
710
60
0
800
GM 10
Submersible drainage pump constructed from composite polymers.
Shaft of chrome steel AISI 430.
2-pole induction motor, 50Hz (n ≈ 2900 rpm).
Single-phase 230 V +/-10% with thermal protector.
Float switch for automatic operation.
5 m cable and control box QM 6,3 with capacitor.
Liquid temperature up to 35 °C
0 Imp. g.p.m.10 20 30 40
8
H ft
m
6 20
GM 10
10
0 0
0 m3/h 3 6 9 12
0 Q 50 100 150 200
l/min
347
GEO 230 Automatic waste water collecting
and lifting station
Pumps characteristics
GEO 230-GX..
Features
Automatic collecting and lifting station - for clean water GXR pump series.
- for waste water GXV pump series.
It includes:
1 tank capacity 230 l
1 single-phase pump with 5 m cable and float switch
1 discharge pipe kit Ø 40 mm in PVC
On demand
1 pump with 10 m cable
1 discharge pipe kit Ø 40 mm in PVC with a ball valve and non-return ball valve
1 support kit with safety float switch and auto-supplied control panel for remote
alarm with horn and flashing light
- extention 300 mm
710
GEO 230-GXRM 9 0,25 2,5 10,2 8,3
GEO 230-GXRM 11 0,37 3,5 12 10,4
GEO 230-GXRM 13 0,45 4,5 13,2 11,7
60
0
800
GXRM, GXVM
Submersible drainage pump in chrome-nickel stainless steel, with vertical delivery port.
GXRM: with open impeller.
GXVM: with free-flow (vortex) impeller.
2-pole induction motor, 50Hz (n ≈ 2900 rpm),
Single-phase 230 V +/-10% with float switch and thermal protector. Incorporated capacitor.
Cable length 5 m.
Liquid temperature up to 35 °C
GXVM GXRM
14 14
GXRM GXVM
12 12
GX
RM
10 13 10
GX
RM GX
11 VM
25-
H H 10
GX
m GX m VM
RM 25-
9 8
6 6
GX
VM
25-
6
4 4
2 2
0 0
0 m3/h 5 10 15 0 m3/h 5 10 15
Q Q
0 l/min 50 100 150 200 250 0 l/min 50 100 150 200 250
348
GEO 230 Automatic clear water collecting
and lifting station
Pumps characteristics
GEO 230-GQR..
Features
Automatic collecting and lifting station for clean water with GQR pump series.
It includes:
1 tank capacity 230 l
1 pump - single-phase with 10 m cable and float switch
- three-phase with 10 m cable with support and float switch kit
1 control box for three-phase version
1 discharge pipe kit Ø 50 mm in PVC
On demand
1 discharge pipe kit Ø 50 mm in PVC with a ball valve and non-return ball valve
1 support kit with safety float switch and auto-supplied control panel for remote
alarm with horn and flashing light
- extention 300 mm
710
GEO 230-GQRM 10-18 1,1 8 30 17,5
GEO 230-GQRM 10-20 1,5 13 30 19,5
GQR
Single-impeller submersible drainage pump, with vertical delivery port.
GQR: with open impeller.
2-pole induction motor, 50Hz (n ≈ 2900 rpm),
GQR: three-phase 400 V +/-10%;
GQRM: Single-phase 230 V +/-10% with float switch and thermal protector.
Incorporated capacitor.
Cable length 10 m.
Liquid temperature up to 35 °C
6 20
4
10
2
0 0
0 m3/h 10 20 30
Q l/min
0 100 200 300 400 500
349
GEO 230 Automatic waste water collecting
and lifting station
Pumps characteristics
GEO 230-GQR..
Features
Automatic collecting and lifting station for clean water with GQR pump series.
It includes:
1 tank capacity 230 l
1 pump - single-phase 10 m cable and float switch
- three-phase with 10 cable with support kit and float switch
1 control box for three-phase version
1 duck foot coupling kit
1 discharge pipe kit Ø 63 mm in PVC with a ball valve and non-return ball
valve
On demand
1 safety float switch (with support for single-phase version) and auto-
supplied control panel for remote alarm with horn and flashing light
- extention 300 mm
Single-phase type 1 ~ 230 V Q max H max
kW A m3/h m
GEO 230-GQRM 10 32-10 0,45 3,1 18 9,5
GEO 230-GQRM 10 32-12 0,55 3,6 21 11,6
GEO 230-GQRM 10 32-14 0,75 4,6 24 13,5
GEO 230-GQRM 10 32-16 0,9 6 27 15,5
710
GEO 230-GQRM 10 32-18 1,1 8 30 17,5
GEO 230-GQRM 10 32-20 1,5 13 30 19,5
GQR
Single-impeller submersible drainage pump, with horizontal delivery port.
GQR: with open impeller.
2-pole induction motor, 50Hz (n ≈ 2900 rpm),
GQR: three-phase 400 V +/-10%;
GQRM: Single-phase 230 V +/-10% with float switch and thermal protector.
Incorporated capacitor.
Cable length 10 m.
Liquid temperature up to 35 °C
6 20
4
10
2
0 0
0 m3/h 10 20 30
Q l/min
0 100 200 300 400 500
350
GEO 230 Automatic waste water collecting
and lifting station
Pumps characteristics
GEO 230-GX..
Features
Automatic waste water collecting and lifting station GX 40 pump series.
It includes:
1 tank capacity 230 l
1 pump - single-phase with 10 m cable and float switch
- three-phase with 10 m cable with support and float switch kit
1 control box for three-phase version
1 discharge pipe kit Ø 50 mm in PVC
On demand
1 discharge pipe kit Ø 50 mm in PVC with a ball valve and non-return ball
valve
1 safety float switch (with support for single-phase version) and auto-
supplied control panel for remote alarm with horn and flashing light
- extention 300 mm
710
GEO 230-GXVM 40-9 0,9 6 21 8,1
GXC, GXV
Submersible sewage and drainage pumps in chrome-nickel stainless steel, with vertical delivery port.
GXC, with two-passage impeller.
GXV: with free-flow (vortex) impeller
2-pole induction motor, 50Hz (n ≈ 2900 rpm).
GXC, GXV: three-phase 400 V; +/-10%
GXCM, GXVM: single-phase 230 V +/-10%, with float switch and thermal protector.
Incorporated capacitor.
Cable length 10 m.
Liquid temperature up to 35 °C
30
12 40
H 8
m ft ft
10 H
m
GX GXV
GX 30
C4 6 V4 4 20
GX
8 GX 0-1
3 V4 0-8 0-9
C4 0-7
0-1
0
6 20
4
10
4
10 2
2
0 0 0 0
0 m 3/h 6 12 18 24 30 0 m 3/h 6 12 18 24
Q Q
0 l/min 100 200 300 400 500 0 l/min 100 200 300 400
72.918-N
351
GEO 230 Automatic waste water collecting
and lifting station
Pumps characteristics
GEO 230-GQG Features
Automatic sewage water collecting and lifting station with grinder pumps
GQG series.
It includes:
1 tank capacity 230 l
1 pump - single-phase with 10 m cable without float switch
- three-phase with 10 m cable
1 support kit with float switch
1 control box (with capacitor for single-phase motors)
1 duck foot coupling kit
1 discharge pipe kit Ø 63 mm in PVC with a ball valve and non-return ball
valve
On demand
1 safety float switch and auto-supplied control panel for remote alarm with
horn and flashing light
- extention 300 mm
710
Three-phase type 3 ~ 400 V Q max H max
kW A m3/h m
GEO 230-GQG 6-18 0,9 2,3 13,2 16,5
GEO 230-GQG 6-21 1,1 2,8 15 19,2
GEO 230-GQG 6-25 1,5 3,8 16,8 23 60
0
800
GQG
Submersible pumps with high power grinder, with horizontal delivery port.
2-pole induction motor, 50Hz (n ≈ 2900 rpm)
GQG: three-phase 400 V +/-10%;
GQGM: Single-phase 230 V +/-10% complete control box with thermal protector and
capacitors (without float switch).
10 m cable.
Liquid temperature up to 35 °C.
0 U.S. g.p.m. 10 20 30 40 50 60 70
30
90
GQG
80
6-25
70
20 6-21
60
H 6-18
m 50
ft
40
10
30
20
10
0 0
0 m3/h 5 10 15 18
Q l/min
0 50 100 150 200 250 300
352
GEO 230 Automatic waste water collecting
and lifting station
Pumps characteristics
GEO 230-GQS 40 GEO 230-GQS 50 Features
Automatic waste water collecting and lifting station GQS series.
It includes:
1 tank capacity 230 l
1 pump - single-phase 10 m cable and float switch
- three-phase with 10 cable with support kit and float switch
1 control box for three-phase version
For GQS 40: 1 discharge pipe kit Ø 50 mm in PVC
For GQS 50: 1 discharge pipe kit Ø 63 mm in PVC with a ball valve and
non-return ball valve
On demand
For GQS 40: 1 discharge pipe kit Ø 50 mm in PVC with a ball valve and
non-return ball valve
1 safety float switch (with support for single-phase version) and auto-
1 ~ 230 V Q max H max supplied control panel for remote alarm with horn and flashing light
Single-phase type - extention 300 mm
kW A m3/h m
GEO 230-GQSM 40-9 0,45 4,5 21 8,8
GEO 230-GQSM 50-8 0,55 4,3 24 7,4
GEO 230-GQSM 50-9 0,75 4,8 27 8,8
GEO 230-GQSM 50-11 0,9 6,6 33 10,5
GEO 230-GQSM 50-13 1,1 8,4 36 12,5
710
GEO 230-GQSM 50-15 1,5 13 36 14,4
GQS
Single-impeller submersible pumps, with vertical delivery port.
GQS: with free-flow (vortex) impeller
2-pole induction motor, 50Hz (n ≈ 2900 rpm)
GQS: three-phase 400 V +/-10%;
GQSM: single-phase 230 V +/-10%, with float switch and thermal protector.
Incorporated capacitor.
Cable length 10 m.
Liquid temperature up to 35 °C
H
m 50
14 GQS ft
50-15
GQS 40
12 50-13
GQS
10 50-1 1
30
GQS
50-9
8
6 20
GQS
50-8
4
GQ
S4 10
0-9
2
0 0
0 m3/h 10 20 30 36
0
Q l/min 100 200 300 400 500 600
353
GEO 230 Automatic waste water collecting
and lifting station
Pumps characteristics
GEO 230-GQN
Features
Automatic waste water collecting and lifting station GQN series.
It includes:
1 tank capacity 230 l
1 pump - single-phase 10 m cable and float switch
- three-phase with 10 cable with support kit and float switch
1 control box for three-phase version
1 discharge pipe kit Ø 63 mm in PVC with a ball valve and non-return ball
valve
On demand
1 safety float switch (with support for single-phase version) and auto-
supplied control panel for remote alarm with horn and flashing light
- extention 300 mm
710
Three-phase type 3 ~ 400 V Q max H max
kW A m3/h m
GEO 230-GQN 50-13 0,9 2,3 36 11,6
GEO 230-GQN 50-15 1,1 3,3 42 13,5 60
0
GEO 230-GQN 50-17 1,5 4,5 48 15,7 800
GQN
Single-impeller submersible pumps, with vertical delivery port.
GQN: with channels impeller (with two-passage)
2-pole induction motor, 50Hz (n ≈ 2900 rpm)
GQN: three-phase 400 V +/-10%;
GQNM: single-phase 230 V +/-10%, with float switch and thermal protector.
Incorporated capacitor.
Cable length 10 m.
Liquid temperature up to 35 °C
H
m 50
14 ft
GQ
N5 40
12 0-1
7
GQ
10 N5
0-1
5
30
GQ
8 N5
0-1
3
6 20
4
10
2
0 0
0 m3/h 10 20 30 40 50
0
Q l/min 200 300 400 500 600 700 800
354
GEO 230 Automatic waste water collecting
and lifting station
Pumps characteristics
GEO 230-GQV
Features
Automatic waste water collecting and lifting station GQV series.
It includes:
1 tank capacity 230 l
1 pump - single-phase with 10 m cable, without float switch
- three-phase with 10 cable, without float switch
1 support kit with float switch
1 control box
1 duck foot coupling kit
1 discharge pipe kit Ø 63 mm in PVC/inox with a ball valve and non-return
ball valve
On demand
1 safety float switch and auto-supplied control panel for remote alarm with
horn and flashing light
- extention 300 mm
Single-phase type 1 ~ 230 V Q max H max
kW A m3/h m
GEO 230-GQVM 50-8 0,55 4,3 24 7,4
GEO 230-GQVM 50-9 0,75 4,8 27 8,8
GEO 230-GQVM 50-11 0,9 6,6 33 10,5
GEO 230-GQVM 50-13 1,1 8,4 36 12,5
710
GEO 230-GQVM 50-15 1,5 13 36 14,4
GQV
Single-impeller submersible pumps, with horizontal delivery port.
GQV: with free-flow (vortex) impeller
2-pole induction motor, 50Hz (n ≈ 2900 rpm)
GQV: three-phase 400 V +/-10%;
GQVM: single-phase 230 V +/-10%, with thermal protector, with built-in capacitor (without float switch).
Cable length 10 m.
Liquid temperature up to 35 °C
H
m 50
14 GQS, ft
GQV
50-15
GQS 40
12 , GQ
V 50-1
3
GQS,
10 GQV
50-11
30
GQS
, GQ
8 V 50-9
GQS
, GQ
V 50
6 -8 20
4
10
2
0 0
0 m3/h 10 20 30 36
0
Q l/min 100 200 300 400 500 600
355
GEO 230 Automatic waste water collecting
and lifting station
Pumps characteristics
GEO 230-GM.. Features
Automatic waste water collecting and lifting station GMV, GMC series.
It includes:
1 tank capacity 230 l
1 pump - single-phase 10 m cable and float switch
- three-phase with 10 cable with support kit and float switch
1 control box for three-phase version
1 discharge pipe kit Ø 63 mm in PVC with a ball valve and non-return ball
valve
On demand
1 safety float switch (with support for single-phase version) and auto-
supplied control panel for remote alarm with horn and flashing light
- extention 300 mm
710
Three-phase type 3 ~ 400 V Q max H max
kW A m3/h m
GEO 230-GMC 50CE 0,75 1,9 36 9,5
GEO 230-GMC 50BE 1,1 2,7 42 12,5
GEO 230-GMC 50AE 1,5 3,8 48 14,5
60
0
GEO 230-GMV 50CE 0,75 1,9 31 8 800
GEO 230-GMV 50BE 1,1 2,7 35 9,5
GEO 230-GMV 50AE 1,5 3,8 39 11,5
GMC, GMV
Submersible sewage and drainage pumps.
GMC, with single-channel impeller.
GMV, with free-flow (vortex) impeller.
2-pole induction motor, 50Hz (n ≈ 2900 rpm)
GMV, GMC: three-phase 400 V +/-10%;
with 2 built-in thermal protectors to be connected to the control panel.
GMVM, GMVM: single-phase 230 V ± 10%, built-in thermal protector and built-in capacitor.
Float switch for automatic operation.
Cable length 10 m.
Liquid temperature up to 35 °C.
0 3
0 0 0
0 m /h 12 18 24 30 36 42 48 0 m 3/h 12 18 24 30 36 42
0
Q l/min 200 300 400 500 600 700 800 0
Q l/min 200 300 400 500 600 700
72.868.C
356
GEO 230 Automatic waste water collecting
and lifting station
Pumps characteristics
GEO 230-GM.. Features
Automatic waste water collecting and lifting station GMV, GMC series.
It includes:
1 tank capacity 230 l
1 pump - single-phase 10 m cable and float switch
- three-phase with 10 cable with support kit and float switch
1 control box for three-phase version
1 duck foot coupling kit
1 discharge pipe kit Ø 63 mm in PVC with a ball valve and non-return ball
valve
On demand
1 safety float switch (with support for single-phase version) and auto-
supplied control panel for remote alarm with horn and flashing light
- extention 300 mm
710
Three-phase type 3 ~ 400 V Q max H max
kW A m3/h m
GEO 230-GMC 50-65C 0,75 1,9 36 9,5
GEO 230-GMC 50-65B 1,1 2,7 42 12,5
GEO 230-GMC 50-65A 1,5 3,8 48 14,5
60
0
GEO 230-GMV 50-65C 0,75 1,9 31 8 800
GEO 230-GMV 50-65B 1,1 2,7 35 9,5
GEO 230-GMV 50-65A 1,5 3,8 39 11,5
GMC, GMV
Submersible sewage and drainage pumps.
GMC, with single-channel impeller.
GMV, with free-flow (vortex) impeller.
2-pole induction motor, 50Hz (n ≈ 2900 rpm)
GMV, GMC: three-phase 400 V +/-10%;
with 2 built-in thermal protectors to be connected to the control panel.
GMVM, GMVM: single-phase 230 V ± 10%, built-in thermal protector and built-in capacitor.
Float switch for automatic operation.
Cable length 10 m.
Liquid temperature up to 35 °C.
0 3
0 0 0
0 m /h 12 18 24 30 36 42 48 0 m 3/h 12 18 24 30 36 42
0
Q l/min 200 300 400 500 600 700 800 0
Q l/min 200 300 400 500 600 700
72.868.C
357
GEO 500 Automatic clear water collecting
and lifting station
Pumps characteristics
GEO 500-GM 10
Features
Automatic clear water collecting and lifting station with GM 10 pump series.
It includes:
1 tank capacity 500 l
2 single-phase pump with 5 m cable without float switch
1 support kit with 2 float switch
1 control box
2 discharge pipe kit Ø 40 mm in PVC
On demand
2 single-phase pumps with 10 m cable, without float switch
2 discharge pipe kit Ø 40 mm in PVC with a ball valve and non-return ball valve
1 safety float switch and auto-supplied control panel for remote alarm with horn
and flashing light
- extention 300 mm
710
12
00
800
GM 10
Submersible drainage pump constructed from composite polymers.
Shaft of chrome steel AISI 430.
2-pole induction motor, 50Hz (n ≈ 2900 rpm).
Single-phase 230 V +/-10% with thermal protector (without float switch).
5 m cable and control box with capacitor.
Liquid temperature up to 35 °C
H
m
6
GM 10
0 3
0 m /h 3 6 9 12
Q
0 l/min 50 100 150 200
358
GEO 500 Automatic waste water collecting
and lifting station
Pumps characteristics
GEO 500-2GX..
Features
Automatic collecting and lifting station - for clean water with GXR pump series
- for waste water with GXV pump series.
It includes:
1 tank capacity 500 l
2 single-phase pump with 5 m cable without float switch
1 support kit with 2 float switch
1 control box
2 discharge pipe kit Ø 40 mm in PVC
On demand
2 single-phase pumps with 10 m cable, without float switch
2 discharge pipe kit Ø 40 mm in PVC with a ball valve and non-return ball valve
1 safety float switch and auto-supplied control panel for remote alarm with horn
and flashing light
- extention 300 mm
Single-phase type 1 ~ 230 V Q max H max
kW A m3/h m
GEO 500-2GXVM 25-6 0,25x2 2,5x2 10,2x2 5,7
GEO 500-2GXVM 25-8 0,37x2 3,5x2 12x2 7,8
GEO 500-2GXVM 25-10 0,45x2 4,5x2 13,2x2 9,5
GEO 500-2GXRM 9 0,25x2 2,5x2 10,2x2 8,3
GEO 500-2GXRM 11 0,37x2 3,5x2 12x2 10,4
710
GEO 500-2GXRM 13 0,45x2 4,5x2 13,2x2 11,7
12
00
800
GXRM, GXVM
Submersible drainage pump in chrome-nickel stainless steel, with vertical delivery port.
GXRM: with open impeller.
GXVM: with free-flow (vortex) impeller.
2-pole induction motor, 50Hz (n ≈ 2900 rpm),
Single-phase 230 V +/-10% with thermal protector. Incorporated capacitor.
Cable length 5 m.
Liquid temperature up to 35 °C
GXVM
GXRM
14 14
GXRM GXVM
12 12
GX
RM
10 13 10
GX
RM GX
11 VM
25-
H H 10
GX
m GX m VM
RM 25-
9 8
6 6
GX
VM
25-
6
4 4
2 2
0 0
0 m3/h 5 10 15 0 m3/h 5 10 15
Q Q
0 l/min 50 100 150 200 250 0 l/min 50 100 150 200 250
359
GEO 500 Automatic clear water collecting
and lifting station
Pumps characteristics
GEO 500-2GQR
Features
Automatic collecting and lifting station for clean water with GQR pump series
It includes:
1 tank capacity 500 l
2 pumps - single-phase with 10 m cable without float switch
- three-phase with 10 m cable
1 support kit with 2 float switch
1 control box
2 discharge pipe kit Ø 50 mm in PVC
On demand
2 discharge pipe kit Ø 50 mm in PVC with a ball valve and non-return ball valve
1 safety float switch and auto-supplied control panel for remote alarm with horn
and flashing light
- extention 300 mm
710
Three-phase type 3 ~ 400 V Q max H max
kW A m3/h m
GEO 500-2GQR 10-10 0,45x2 1,2x2 18x2 9,5
GEO 500-2GQR 10-12 0,55x2 1,4x2 21x2 11,6 12
GEO 500-2GQR 10-14 0,75x2 1,6x2 24x2 13,5 00
GQR
Single-impeller submersible drainage pump, with vertical delivery port.
GQR: with open impeller.
2-pole induction motor, 50Hz (n ≈ 2900 rpm),
GQR: three-phase 400 V +/-10%;
GQRM: Single-phase 230 V +/-10% with thermal protector and incorporated capacitor (without
float switch).
Cable length 10 m.
Liquid temperature up to 35 °C.
6 20
4
10
2
0 0
0 m3/h 10 20 30
Q l/min
0 100 200 300 400 500
360
GEO 500 Automatic waste water collecting
and lifting station
Pumps characteristics
GEO 500-2GQR
Features
Automatic waste water collecting and lifting station with GQR pump series.
It includes:
1 tank capacity 500 l
2 pumps - single-phase 10 m cable without float switch
- three-phase with 10 cable
1 support kit with 2 float switch
1 control box
2 duck foot coupling kit
2 discharge pipe kit Ø 63 mm in PVC with a ball valve and non-return ball
valve
On demand
1 safety float switch and auto-supplied control panel for remote alarm
with horn and flashing light
- extention 300 mm
Single-phase type 1 ~ 230 V Q max H max
kW A m3/h m
GEO 500-2GQRM 10 32-10 0,45x2 3,1x2 18x2 9,5
GEO 500-2GQRM 10 32-12 0,55x2 3,6x2 21x2 11,6
GEO 500-2GQRM 10 32-14 0,75x2 4,6x2 24x2 13,5
GEO 500-2GQRM 10 32-16 0,9x2 6x2 27x2 15,5
GEO 500-2GQRM 10 32-18 1,1x2 8x2 30x2 17,5
GEO 500-2GQRM 10 32-20 1,5x2 13x2 30x2 19,5
710
Three-phase type 3 ~ 400 V Q max H max
kW A m3/h m
GEO 500-2GQR 10 32-10 0,45x2 1,2x2 18x2 9,5
GEO 500-2GQR 10 32-12 0,55x2 1,4x2 21x2 11,6 12
00
GEO 500-2GQR 10 32-14 0,75x2 1,6x2 24x2 13,5
GEO 500-2GQR 10 32-16 0,9x2 2,3x2 27x2 15,5 800
GEO 500-2GQR 10 32-18 1,1x2 2,8x2 30x2 17,5
GEO 500-2GQR 10 32-20 1,5x2 3,8x2 30x2 19,5
GQR
Single-impeller submersible drainage pump, with horizontal delivery port.
GQR: with open impeller.
2-pole induction motor, 50Hz (n ≈ 2900 rpm),
GQR: three-phase 400 V +/-10%;
GQRM: single-phase 230 V +/-10%, with thermal protector, with built-in capacitor (without float
switch).
10 m cable.
Liquid temperature up to 35 °C
6 20
4
10
2
0 0
0 m3/h 10 20 30
Q l/min
0 100 200 300 400 500
361
GEO 500 Automatic waste water collecting
and lifting station
Pumps characteristics
GEO 500-2GX..
Features
Automatic waste water collecting and lifting station with GX 40 pump
series.
It includes:
1 tank capacity 500 l
2 pumps - single-phase with 10 m cable without float switch
- three-phase with 10 m cable
1 support kit with 2 float switch
1 electric control box
2 discharge pipe kit Ø 50 mm in PVC
On demand
2 discharge pipe kit Ø 50 mm in PVC with a ball valve and non-return ball valve
1 safety float switch and auto-supplied control panel for remote alarm with
horn and flashing light
- extention 300 mm
Single-phase type 1 ~ 230 V Q max H max
kW A m3/h m
GEO 500-2GXCM 40-10 0,55x2 4,6x2 21x2 9
GEO 500-2GXCM 40-13 0,9x2 6,6x2 26x2 11,6
GEO 500-2GXVM 40-7 0,55x2 4,6x2 15x2 6,2
GEO 500-2GXVM 40-8 0,75x2 5,4x2 18x2 7,2
GEO 500-2GXVM 40-8 0,9x2 6x2 21x2 8,1
710
Three-phase type 3 ~ 400 V Q max H max
kW A m3/h m
GEO 500-2GXC 40-10 0,55x2 1,6x2 21x2 9
GEO 500-2GXC 40-13 0,9x2 2,3x2 26x2 11,6 12
00
GEO 500-2GXV 40-7 0,55x2 1,6x2 15x2 6,2
GEO 500-2GXV 40-8 0,75x2 2,2x2 18x2 7,2 800
GEO 500-2GXV 40-9 0,9x2 2,3x2 21x2 8,1
GXC, GXV
Submersible sewage and drainage pumps in chrome-nickel stainless steel, with vertical delivery port.
GXC, with single-channel impeller.
GXV: with free-flow (vortex) impeller
2-pole induction motor, 50Hz (n ≈ 2900 rpm).
GXC, GXV: three-phase 400 V +/-10%;
GXCM, GXVM: single-phase 230 V +/-10%, with thermal protector and incorporated capacitor (without
float switch).
Cable length 10 m.
Liquid temperature up to 35 °C
30
12 40
H 8
m ft ft
10 H
m
GX GXV
GX 30
C4 6 V4 4 20
GX
8 GX 0-1
3 V4 0-8 0-9
C4 0-7
0-1
0
6 20
4
10
4
10 2
2
0 0 0 0
0 m 3/h 6 12 18 24 30 0 m 3/h 6 12 18 24
Q Q
0 l/min 100 200 300 400 500 0 l/min 100 200 300 400
72.918-N
362
GEO 500 Automatic waste water collecting
and lifting station
Pumps characteristics
GEO 500-2GQG Features
Automatic sewage water collecting and lifting station with grinder pumps
GQG series.
It includes:
1 tank capacity 500 l
2 pumps - single-phase 10 m cable without float switch
- three-phase with 10 cable
1 support kit with 2 float switch
1 electric control box (with capacitor for single-phase motors)
2 duck foot coupling kit
2 discharge pipe kit Ø 63 mm in PVC with a ball valve and non-return ball
valve
On demand
1 safety float switch and auto-supplied control panel for remote alarm with
horn and flashing light
- extension 300 mm
710
kW A m3/h m
GEO 500-2GQG 6-18 0,9x2 2,3x2 13,2x2 16,5
GEO 500-2GQG 6-21 1,1x2 2,8x2 15x2 19,2
GEO 500-2GQG 6-25 1,5x2 3,8x2 16,8x2 23
12
00
800
GQG
Submersible pumps with high power grinder, with horizontal delivery port.
2-pole induction motor, 50Hz (n ≈ 2900 rpm)
GQG: three-phase 400 V +/-10%;
GQGM: Single-phase 230 V +/-10% complete control box with thermal protector and capacitors
(without float switch).
10 m cable.
Liquid temperature up to 35 °C.
0 U.S. g.p.m. 10 20 30 40 50 60 70
30
90
GQG
80
6-25
70
20 6-21
60
H 6-18
m 50
ft
40
10
30
20
10
0 0
0 m3/h 5 10 15 18
Q l/min
0 50 100 150 200 250 300
363
GEO 500 Automatic waste water collecting
and lifting station
Pumps characteristics
GEO 500-2GQS 40 GEO 500-2GQS 50
Features
Automatic waste water collecting and lifting station GQS series.
It includes:
1 tank capacity 500 l
2 pumps - single-phase 10 m cable without float switch
- three-phase with 10 cable
1 support kit with 2 float switch
1 control box for three-phase version
For GQS 50: 2 discharge pipe kit Ø 50 mm in PVC
For GQS 50: 2 discharge pipe kit Ø 63 mm in PVC with a ball valve and
non-return ball valve
On demand
For GQS 50: 2 discharge pipe kit Ø 50 mm in PVC with a ball valve and non-
return ball valve
Single-phase type 1 ~ 230 V Q max H max
1 safety float switch and auto-supplied control panel for remote alarm
kW A m3/h m with horn and flashing light
GEO 500-2GQSM 40-9 0,45x2 4,5x2 21x2 8,8 - extention 300 mm
GEO 500-2GQSM 50-8 0,55x2 4,3x2 24x2 7,4
GEO 500-2GQSM 50-9 0,75x2 4,8x2 27x2 8,8
GEO 500-2GQSM 50-11 0,9x2 6,6x2 33x2 10,5
GEO 500-2GQSM 50-13 1,1x2 8,4x2 36x2 12,5
GEO 500-2GQSM 50-15 1,5x2 13x2 36x2 14,4
710
kW A m3/h m
GEO 500-2GQS 40-9 0,45x2 1,6x2 21x2 8,8
GEO 500-2GQS 50-8 0,55x2 1,5x2 24x2 7,4
GEO 500-2GQS 50-9 0,75x2 1,8x2 27x2 8,8
GEO 500-2GQS 50-11 0,9x2 2,3x2 33x2 10,5 12
00
GEO 500-2GQS 50-13 1,1x2 3x2 36x2 12,5
GEO 500-2GQS 50-15 1,5x2 4x2 36x2 14,4 800
GQS
Single-impeller submersible pumps, with vertical delivery port.
GQS: with free-flow (vortex) impeller
2-pole induction motor, 50Hz (n ≈ 2900 rpm)
GQS: three-phase 400 V +/-10%;
GQSM: single-phase 230 V +/-10%, with thermal protector, with built-in capacitor (without float switch).
10 m cable.
Liquid temperature up to 35 °C
H
m 50
14 GQS ft
50-15
GQS 40
12 50-13
GQS
10 50-1 1
30
GQS
50-9
8
6 20
GQS
50-8
4
GQ
S4 10
0-9
2
0 0
0 m3/h 10 20 30 36
0
Q l/min 100 200 300 400 500 600
364
GEO 500 Automatic waste water collecting
and lifting station
Pumps characteristics
GEO 500-2GQN
Features
Automatic waste water collecting and lifting station GQN series.
It includes:
1 tank capacity 500 l
2 pumps - single-phase 10 m cable without float switch
- three-phase with 10 cable
1 support kit with 2 float switch
1 control box for three-phase version
2 discharge pipe kit Ø 63 mm in PVC with a ball valve and non-return
ball valve
On demand
1 safety float switch and auto-supplied control panel for remote alarm
with horn and flashing light
- extention 300 mm
710
Three-phase type 3 ~ 400 V Q max H max
kW A m3/h m
GEO 500-2GQN 50-13 0,9x2 2,3x2 36x2 11,6
GEO 500-2GQN 50-15 1,1x2 3,3x2 42x2 13,5
GEO 500-2GQN 50-17 1,5x2 4,5x2 48x2 15,7 12
00
800
GQN
Single-impeller submersible pumps, with vertical delivery port.
GQN: with channels impeller (with two-passage)
2-pole induction motor, 50Hz (n ≈ 2900 rpm)
GQN: three-phase 400 V +/-10%;
GQNM: single-phase 230 V +/-10%, with thermal protector, with built-in capacitor (without float switch).
10 m cable.
Liquid temperature up to 35 °C
H
m 50
14 ft
GQ
N5 40
12 0-1
7
GQ
10 N5
0-1
5
30
GQ
8 N5
0-1
3
6 20
4
10
2
0 0
0 m3/h 10 20 30 40 50
0
Q l/min 200 300 400 500 600 700 800
365
GEO 500 Automatic waste water collecting
and lifting station
Pumps characteristics
GEO 500-2GQV
Features
Automatic waste water collecting and lifting station with GQV pump series.
It includes:
1 tank capacity 500 l
2 pumps - single-phase 10 m cable without float switch
- three-phase with 10 cable
1 support kit with 2 float switch
1 control box
2 duck foot coupling kit
2 discharge pipe kit Ø 63 mm in PVC with a ball valve and non-return
ball valve
On demand
1 safety float switch and auto-supplied control panel for remote alarm
with horn and flashing light
- extention 300 mm
Single-phase type 1 ~ 230 V Q max H max
kW A m3/h m
GEO 500-2GQVM 50-8 0,55x2 4,3x2 24x2 7,4
GEO 500-2GQVM 50-9 0,75x2 4,8x2 27x2 8,8
GEO 500-2GQVM 50-11 0,9x2 6,6x2 33x2 10,5
GEO 500-2GQVM 50-13 1,1x2 8,4x2 36x2 12,5
GEO 500-2GQVM 50-15 1,1x2 13x2 36x2 12,5
710
Three-phase type 3 ~ 400 V Q max H max
kW A m3/h m
GEO 500-2GQV 50-8 0,55x2 1,5x2 24x2 7,4
GEO 500-2GQV 50-9 0,75x2 1,8x2 27x2 8,8
GEO 500-2GQV 50-11 0,9x2 2,3x2 33x2 10,5 12
00
GEO 500-2GQV 50-13 1,1x2 3x2 36x2 12,5
800
GEO 500-2GQV 50-15 1,5x2 4x2 36x2 14,4
GQV
Single-impeller submersible pumps, with horizontal delivery port.
GQV: with free-flow (vortex) impeller
2-pole induction motor, 50Hz (n ≈ 2900 rpm)
GQV: three-phase 400 V +/-10%;
GQVM: single-phase 230 V +/-10%, with thermal protector, with built-in capacitor (without float switch).
10 m cable.
Liquid temperature up to 35 °C
H
m 50
14 GQS, ft
GQV
50-15
GQS 40
12 , GQ
V 50-1
3
GQS,
10 GQV
50-11
30
GQS
, GQ
8 V 50-9
GQS
, GQ
V 50
6 -8 20
4
10
2
0 0
0 m3/h 10 20 30 36
0
Q l/min 100 200 300 400 500 600
366
GEO 500 Automatic waste water collecting
and lifting station
Pumps characteristics
GEO 500-2GM.. Features
Automatic waste water collecting and lifting station GMV, GMC series.
It includes:
1 tank capacity 500 l
2 pumps - single-phase 10 m cable without float switch
- three-phase with 10 cable
1 support kit with 2 float switch
1 control box for three-phase version
2 discharge pipe kit Ø 63 mm in PVC with a ball valve and non-return
ball valve
On demand
1 safety float switch and auto-supplied control panel for remote alarm
with horn and flashing light
- extention 300 mm
710
kW A m3/h m
GEO 500-2GMC 50CE 0,75x2 1,9x2 36x2 9,5
GEO 500-2GMC 50BE 1,1x2 2,7x2 42x2 12,5
GEO 500-2GMC 50AE 1,5x2 3,8x2 48x2 14,5
GEO 500-2GMV 50CE 0,75x2 1,9x2 31x2 8 12
00
GEO 500-2GMV 50BE 1,1x2 2,7x2 35x2 9,5
800
GEO 500-2GMV 50AE 1,5x2 3,8x2 39x2 11,5
GMC, GMV
Submersible sewage and drainage pumps.
GMC, with single-channel impeller.
GMV, with free-flow (vortex) impeller.
2-pole induction motor, 50Hz (n ≈ 2900 rpm)
GMV, GMC: three-phase 400 V +/-10%;
with 2 built-in thermal protectors to be connected to the control panel.
GMVM, GMVM: single-phase 230 V ± 10%, built-in thermal protector and built-in capacitor.
(without float switch)
Cable length 10 m.
Liquid temperature up to 35 °C.
0 3
0 0 0
0 m /h 12 18 24 30 36 42 48 0 m 3/h 12 18 24 30 36 42
0
Q l/min 200 300 400 500 600 700 800 0
Q l/min 200 300 400 500 600 700
72.868.C
367
GEO 500 Automatic waste water collecting
and lifting station
Pumps characteristics
GEO 500-2GM.. Features
Automatic waste water collecting and lifting station GMV, GMC series.
It includes:
1 tank capacity 500 l
2 pumps - single-phase 10 m cable without float switch
- three-phase with 10 cable
1 support kit with 2 float switch
1 control box for three-phase version
2 duck foot coupling kit
2 discharge pipe kit Ø 63 mm in PVC with a ball valve and non-return
ball valve
On demand
1 safety float switch and auto-supplied control panel for remote alarm
with horn and flashing light
- extention 300 mm
Single-phase type 1 ~ 230 V Q max H max
kW A m3/h m
GEO 500-2GMCM 50-65C 0,75x2 4,5x2 36x2 9,5
GEO 500-2GMCM 50-65B 1,1x2 6,5x2 42x2 12,5
GEO 500-2GMVM 50-65C 0,75x2 4,5x2 31x2 8
GEO 500-2GMVM 50-65B 1,1x2 6,5x2 35x2 9,5
710
kW A m3/h m
GEO 500-2GMC 50-65C 0,75x2 1,9x2 36x2 9,5
GEO 500-2GMC 50-65B 1,1x2 2,7x2 42x2 12,5
GEO 500-2GMC 50-65A 1,5x2 3,8x2 48x2 14,5
GEO 500-2GMV 50-65C 0,75x2 1,9x2 31x2 8 12
00
GEO 500-2GMV 50-65B 1,1x2 2,7x2 35x2 9,5
800
GEO 500-2GMV 50-65A 1,5x2 3,8x2 39x2 11,5
GMC, GMV
Submersible sewage and drainage pumps.
GMC, with single-channel impeller.
GMV, with free-flow (vortex) impeller.
2-pole induction motor, 50Hz (n ≈ 2900 rpm)
GMV, GMC: three-phase 400 V +/-10%;
with 2 built-in thermal protectors to be connected to the control panel.
GMVM, GMVM: single-phase 230 V ± 10%, built-in thermal protector and built-in capacitor.
(without float switch)
Cable length 10 m.
Liquid temperature up to 35 °C.
0 3
0 0 0
0 m /h 12 18 24 30 36 42 48 0 m 3/h 12 18 24 30 36 42
0
Q l/min 200 300 400 500 600 700 800 0
Q l/min 200 300 400 500 600 700
72.868.C
368
GEO Automatic waste water collecting
and lifting station
B
A
415
A
335
315
4.93.433
340 300
350
A) Arrangement for : A
Ø 40 mm inlet A
Ø 40 mm outlet
Ø 25 mm relief
390 B) Cable passage with Shuko plug
B
E
545 450 Tank
Serbatoio
kg. 16
kg.16 A
C
15
A
710
570
125 125 C
510
420
4.93.373
800
125 125
600
C
A-C) inlet and relief
B) delivery outlet A
D) G 1 1/2 draining outlet
E) Cable outlet
97
D
369
GEO Automatic waste water collecting
and lifting station
E
Tank Serbatoio
kg. 32 kg. 32
600
545
450 450 A
B
C
A
B
15
C
710
A
570
510
A
C
4.93.389
800
97
125
125
1200
C
A
125 125
C
A-C) inlet and relief D
A
B) delivery outlet
D) G 1 1/2 draining outlet
D
E) Cable outlet
Installation examples
4.93.267
370
GEO Technical appendix
Qr (m3/h)
main only in exceptional cases.
To sizing a lifting station pump it is necessary to calculate
the flow Qtot and the Head hmt necessary for the water 10
drainage.
B
A C
D
FLOW CALCULATION
1
The flow of the lifting pumps can be calculated using
Table1, according to the number of people using the 1 10 100 1000
persons (no.)
persone (n°)
building and the location of the building. It is easy to
calculate the flow Qr of the sewage water. A Houses ----B
----A B Hospitals ----C
C Industry ----D
D Offices
The Qr value is already adjusted by a coefficient that abitazioni ospedali Industrie 2) uffici
includes the peak hours, when the water consumption is
higher. Tabella22
Table
Rainwater
Portata Flow
delle acque meteoriche
The lifting systems of waste water are usually separated 100
from the rainwater system. In case of a mixed system is
required to sum the flow Qm of the rainwater of the Table 2
with the flow Qr of the Table 1.
Qtot = Qr + Qm
A
B C
D
1
HEAD CALCULATION
To calculate the head hmt it is necessary to add the
geodetic head existing between the fluid levels with the
head losses from internal friction created by the flow of the
fluid in the hydraulic pipes and fittings (Figure 1). 0,1
10 20 40 60 80 100 200 400 600 800 1000
After the choice of the discharge pipe diameter, such that area (m2(m
superficie ) 2)
the flow speed it is not lower than 0,7 m/s (to avoid
deposits) and higher than 2,3 m/s, it is possible to ----A Aroofs ----B stone
B on sand ----C Cgravel/pebbles ----D
D gar-
Pietra su sabbia Ciottoli -ghiaia giardini
determine the distributed head loss Hd and concentrated dens Piazzali-tetti
head loss Hv Hc, due to valves and curves (Table 4).
Figure 1
The sum of the head losses DPC is:
∆Pc
Hmt = Hg + Δpc
Hmt
Hg
1) Water arriving from sinks discharge, toilets, showers, washing machines etc.
2) Excluding consumption from industrial processes.
3) The unit flow reference is 1,5 l/min/m2
371
GEO Technical appendix
R
50 0,24 0,85 1,8 3,1 4,6 16,7 35,3 - - - - - - -
acqua
velocity
0,30 0,59 0,89 1,18 1,48 2,96 4,44 - - - - - - d
63 0,08 0,26 0,56 0,95 1,11 5,2 10,9 18,6 34,8 - - - - -
0,18 0,37 0,55 0,73 0,92 1,83 2,75 3,66 5,13 - - - -
d d d d d
75 0,11 0,24 0,4 0,61 2,2 4,6 7,9 14,7 23,4 43 - - - = 0,4 = 0,6 = 0,8 =1 = 1,5
m/sec. R R R R R
0,26 0,39 0,51 0,64 1,29 1,93 2,57 3,6 4,63 6,43 - - -
90 0,05 0,1 0,16 0,25 0,9 1,9 3,3 6,1 9,7 17,8 33,2 - - 0,4 0,11 0,13 0,16 0,23 0,43 0,23
0,18 0,27 0,36 0,45 0,89 1,34 1,79 2,5 3,22 4,47 6,26 - -
0,5 0,18 0,21 0,26 0,37 0,67 0,37
110 0,04 0,06 0,09 0,3 0,67 1,15 2,15 3,4 6,25 11,7 18,5 22,5
0,17 0,2 0,29 0,58 0,87 1,16 1,63 2,10 2,91 4,08 5,24 5,82 0,6 0,25 0,29 0,36 0,52 0,97 0,52
125 0,03 0,05 0,17 0,36 0,6 1,15 1,84 3,37 6,3 10 12,2 0,7 0,34 0,40 0,48 0,70 1,35 0,70
0,18 0,23 0,45 0,68 0,90 1,26 1,63 2,26 3,16 4,06 4,52
HL 0,8 0,45 0,53 0,64 0,93 1,7 0,95
140 0,03 0,1 0,2 0,35 0,65 1,05 1,95 3,6 5,77 7
v 0,18 0,36 0,54 0,72 1,01 1,30 1,80 2,52 3,24 3,60 0,9 0,57 0,67 0,82 1,18 2,2 1,20
160 0,05 0,11 0,18 0,34 0,55 1,02 1,9 3 3,66 1,0 0,7 0,82 1,0 1,45 2,7 1,45
m/100m 0,28 0,41 0,55 0,77 0,99 1,38 1,93 2,48 2,76
m/s 1,5 1,6 1,9 2,3 3,3 6 3,3
180 0,03 0,06 0,1 0,19 0,31 0,57 1,06 1,69 2,05
0,22 0,33 0,43 0,61 0,78 1,09 1,52 1,96 2,17 2,0 2,8 3,3 4,0 5,8 11 5,8
200 0,02 0,04 0,06 0,12 0,18 0,34 0,64 1 1,23 2,5 4,4 5,2 6,3 9,1 17 9,1
0,18 0,26 0,35 0,49 0,63 0,88 1,23 1,59 1,76
3,0 6,3 7,4 9 13 25 13
225 0,02 0,04 0,07 0,1 0,19 0,36 0,57 0,7
0,21 0,28 0,39 0,55 0,70 0,97 1,25 1,39 3,5 8,5 10 12 18 33 18
250 0,02 0,04 0,06 0,12 0,22 0,34 0,42 4,0 11 13 16 23 42 23
0,23 0,32 0,41 0,56 0,79 1,02 1,13
4,5 14 21 26 37 55 37
280 0,01 0,02 0,04 0,07 0,13 0,2 0,24
0,18 0,25 0,32 0,45 0,63 0,81 0,90 5,0 18 29 36 52 67 52
EXAMPLE OF CALCULATION
Suppose it is required to size a lifting station, for a residential building where 80 people live.
The pumps will have to lift waste water up to an additional tank located 5m higher, the linear distance between the 2 tanks is 70 m.
In addition the station will receive rainwater from 400 m2 of tarmac, roof surfaces and 120 m2 of garden.
Considering: Q tot = Qr + Qm
20
It is possible to calculate the Qr from the Table1 which is 4 m3/h, while Qm is obtai- H
ned from the Table 2 and is 36 m3/h ( roofs and tarmac) plus 2 m3/h from gardens, m
with this value Qtot is 42 m3/h. At this flow it will be necessary split the flow between 16
two pumps. GMC
We choose a delivery pipe diameter such that the flow rate with two pumps in ope-
ration does not exceed 2.3 m / sec and not be lower than 0.7 m / s with a single 12
pump. dutydipoint
punto lavoro
he suitable pumps are no. 2 GMCM 50-65B and then it result a station type GEO 500-2GMCM 50-65B.
INSTALLATION EXAMPLE
4.93.267
372
03/2021
Construction
Multi-stage centrifugal submersible pumps with pump jacket in
chrome-nickel stainless steel, with vertical delivery port.
Motor cooled by the pumped water passing between the motor
jacket and the external jacket.
Double shaft seal with oil chamber.
Applications
- For clean water containing solids up to 2 mm grain size.
- For draining rooms or or emptying tanks.
- Extraction of water from ponds, streams or pits and for
rainwater collection.
- For irrigation purposes.
For outdoor use a power supply cable of not less than 10 m
should be used in accordance with: EN 60 335-2-41.
Operating conditions
Liquid temperature up to 35° C.
Maximum immersion depth: 5 m.
Minimum water level with float 100 mm.
Continuous duty.
Motor
2-pole induction motor, 50 Hz (n ≈ 2900 rpm).
MP: three-phase 230 V ± 10%;
three-phase 400 V ± 10%;
MPM: single-phase 230 V,
with float switch and thermal protector.
Incorporated capacitor.
Materials Insulation class F.
Component Material Protection IP X8 (for continuous immersion)
Pump casing Double impregnation humidity-proof dry winding.
Impeller PPO-GF20 (Noryl) Constructed in accordance with: EN 60034-1;
Stage casing EN 60335-1, EN 60335-2-41.
Motor jacket
Pump jacket
Chrome-nickel steel 1.4301 EN 10088 (AISI 304) Other features on request
- Other voltages.
Strainer - Frequency 60 Hz (as per 60 Hz data sheet).
Polypropylene
Handle - Other mechanical seal.
Shaft Chrome-nickel steel 1.4305 EN 10088 (AISI 303) - Cable length 10 m.
Mechanical seal Ceramic alumina/Carbon/NBR - Vertical magnetic float switch.
- Motor suitable for operation with frequency converter.
Seal lubrication oil Oil for food/pharmaceutical machinery
40
MP
MP 204 120
30 100
H
MP 203 ft
H
m 80
20
MP 403 60
40
10
20
0 0
0 m3/h 2,5 5 7,5
0
Q l/min 25 50 75 100 125
0 l/s 0,5 1 1,5 2
373
MP Multi-stage submersible clean water pumps
P1 Max. power input. P2 Rated motor power output. Density ρ = 1000 kg/m3. Kinematic viscosity ν = max 20 mm2/sec.
Tolerances according to UNI EN ISO 9906:2012
fM a
4.93.388
Ø2
176
G 1 1/4
ISO 228
56
Dimensions (1)
TYPE mm kg
fM a MP MPM
374
MP Multi-stage submersible clean water pumps
Installation examples
G 1 1/4
ISO 228
On
TYPE mm
h
max h min h max
Off fM 218 428
MPM 203/A
Ø 176
min 350 x 350
TYPE mm
h min h max
h fM
max MPM 203/A GF 218 308
h MPM 204 GF 218 308
min MPM 403 GF 218 308
3.93.037/3
Ø 176
min 250 x 250
375
MP Multi-stage submersible clean water pumps
Features
Shaft in chrome-nickel
stainless steel.
Easy adjustment of the
float switch: to allow the
adjustement of start/stop
pump levels. Motor cooled by the pumped
water passing between the
motor jacket and the external
jacket.
Oil chamber.
Suction strainer that allows the passage Stage casing and Impeller in PPO-GF20 (Noryl)
of solids up to 2 mm.
The double shaft seal with oil chamber separates the
motor from the water and provides further protection
against accidental operation when dry.
376
03/2021
Construction
PATENTED 5” Close coupled multi-stage submersible pumps.
External jacket in stainless steel AISI 304 and stages Noryl.
MPSM with built-in capacitor, accessible through the delivery
casing.
Hydraulics located below the motor with the motor cooled by
the pumped fluid. Safe operation is possible with the motor
only partially submerged.
Double shaft seal with oil chamber.
The suction strainer prevents the entrance of solids with diame-
ter bigger than 2 mm.
Applications
For water supply from wells, tanks or reservoirs.
For domestic, civil and industrial applications, for garden use,
irrigation and rain water harvesting systems.
Operating conditions
Water temperature up to 35 °C.
Minimum internal diameter of well: 140 mm.
Minimum immersion depth: 100 mm.
Maximum immersion depth: 20 m (with suitable cable length).
Continuous duty.
Motor
2-pole induction motor, 50 Hz (n ≈ 2900 1/min).
MPS : three-phase 230 V ± 10%;
three-phase 400 V ± 10%.
Materials Cable: H07RN8-F, length 15 m, without plug.
Component Material MPSM : single-phase 230 V ± 10%, with thermal protector.
Delivery casing Incorporated capacitor.
External jacket Float switch MPSM.. CG (on demand)
Chrome-nickel steel 1.4301 EN 10088 (AISI 304)
Suction strainer Cable: H07RN8-F, length 15 m, with plug CEI-UNEL 47166.
Motor jacket
Stage casing Insulation class F.
PPO-GF20 (Noryl) Protection IP X8 (for continuous immersion).
Impeller
Shaft Chrome-nickel steel 1.4301 EN 10088 (AISI 304) Triple impregnation humidity-proof dry winding.
Capacitor cover Constructed in accordance with EN 60335-2-41.
Oil chamber cover PPS Polymer (Grivory)
Preload ring stages Special features on request
Support ring preload - Other voltages.
Upper mechanical seal Steatite, carbon, NBR - Frequency 60 Hz (as per 60 Hz data sheet).
Lower mechanical seal Carbon, silicon carbide, NBR - Cable length 20 m.
Seal lubrication oil Oil for food machinery and pharmaceutic use - Motor suitable operation with frequency converter.
90 300
ft
80
250
70
H 200
m
50
150
40
MPS 3
30 100
MPS 5
20
50
10
0 0
0 m3/h 2 4 6 8 10
Q
0 l/min 50 100 150
72.986/1
377
MPS Multi-Stage Submersible Clean Water Pumps
P1 Max. power input. P2 Rated motor power output. Tolerances according to UNI EN ISO 9906:2012 Test results with clean cold water, without gas content.
G 1 1/4
ISO 228
Ø7
fM kg Cable
Cavo H07RN8-F
Pump
230V 230V 400V
mm MPS MPSM 1~ 3~ 3~
fM
MPS 303 - MPSM 303 465 11 12 3G1 mm2 4G1 mm2 4G1 mm2
MPS 304 - MPSM 304 504 11,5 12,5 3G1 mm2 4G1 mm2 4G1 mm2
MPS 305 - MPSM 305 553 12 13 3G1 mm2 4G1 mm2 4G1 mm2
MPS 306 - MPSM 306 577 13,5 15 3G1 mm2 4G1 mm2 4G1 mm2
MPS 307 - MPSM 307 601 14 15,5 3G1 mm2 4G1 mm2 4G1 mm2
MPS 503 - MPSM 503 480 11,5 12,5 3G1 mm2 4G1 mm2 4G1 mm2
MPS 504 - MPSM 504 529 13,5 14,5 3G1 mm2 4G1 mm2 4G1 mm2
MPS 505 - MPSM 505 553 14 15 3G1 mm2 4G1 mm2 4G1 mm2
MPS 506 - MPSM 506 622 15,5 17 3G1,5 mm2 4G1 mm2 4G1 mm2
MPS 507 - MPSM 507 671 17 18,5 3G2,5 mm2 4G1 mm2 4G1 mm2
Ø 133
MPSM ... CG
With float switch pump
(on demand)
378
MPS Multi-Stage Submersible Clean Water Pumps
20 20
50 50
10 10
0 0 0 0
0 m 3/h 1 2 3 4 5 0 m3/h 2 4 6 8
Q Q
0 l/min 20 40 60 80 0 l/min 50 100
40 50
η η
% %
30 40
0 Q m3/h 1 2 3 4 72.987.1
5 0 Q m3/h 2 4 6 72.988
8
379
MPS Multi-Stage Submersible Clean Water Pumps
Features
PATENTED
Innovative Robust
Designed to withstand water hammering and Its robust stainless steel external
the ON-OFF operation of any valve located in construction allows for the pump to
the discharge line. be suspended from the delivery
The impacts generated by water hammering pipe.
or by the closing of the valve are fully
supported by the capacitor cover,which
relieves the stresses on a specific support
made on the stainless steel jacket, without
affecting the plastic hydraulic part.
Low-Noise operation
The design of hydraulic parts, the
Flexible water-filled shroud around the
Allows the inspection of the capacitor motor and the submerged opera-
without disassembling the pump, through tion ensures low noise operation.
the delivery casing.
Reliable
The ball bearings and shaft are sized in
order to reduce stresses, guaranteeing
high reliability in any operating condition. Greater Safety
The double shaft sealing with an oil
chamber separates the motor from
the water and provides further pro-
tection against accidental opera-
Low cost installation tion when dry.
Immersed, without suction pipe and valves.
The cylindrical suction strainer provides
support for the pump when installed on a
flat surface or tank bottom. For operation
with 100 mm minimum water level.
Installation
Max. 1000 mm
max 20 m
Off
Off
0.5 m
min
140 mm
min 3.93.007/3
3.93.007/1 3.93.007/2
Pump in suspended position Pump with float switch (on demand) Installation example
380
03/2021
Construction
PATENTED 5” Close coupled multi-stage submersible pumps.
All parts in contact with the fluid both internal and external
are in chrome-nickle stainless steel.
MXSM with built-in capacitor, accessible through the delivery casing.
Hydraulics located below the motor with the motor cooled by
the pumped fluid. Safe operation is possible with the motor
only partially submerged.
Double shaft seal with oil chamber.
The suction strainer prevents the entrance of solids with diame-
ter bigger than 2 mm.
Applications
For water supply from wells, tanks or reservoirs.
For domestic, civil and industrial applications, for garden use,
irrigation and rain water harvesting systems.
Operating conditions
Water temperature up to 35 °C.
Minimum internal diameter of well: 140 mm.
Minimum immersion depth: 100 mm.
Maximum immersion depth: 20 m (with suitable cable length).
Continuous duty.
Motor
2-pole induction motor, 50 Hz (n ≈ 2900 1/min).
MXS : three-phase 230 V ± 10%;
Materials three-phase 400 V ± 10%.
Cable: H07RN8-F, length 15 m, without plug.
Component Material
MXSM : single-phase 230 V ± 10%, with thermal protector.
Delivery casing Incorporated capacitor.
External jacket Float switch MXSM.. CG up to 10A (on demand)
Suction strainer Cable: H07RN8-F, length 15 m, with plug CEI-UNEL 47166.
Stage casing
Chrome-nickel steel 1.4301 EN 10088 (AISI 304) Insulation class F.
Spacer sleeve
Impeller Protection IP X8 (for continuous immersion).
Motor jacket Triple impregnation humidity-proof dry winding.
Jacket cover Constructed in accordance with EN 60335-2-41.
Oil chamber cover
Shaft Chrome-nickel steel 1.4301 EN 10088 (AISI 304) Special features on request
Upper mechanical seal Steatite, carbon, NBR - Other voltages. - Frequency 60 Hz (as per 60 Hz data sheet).
Lower mechanical seal Ceramic alumina, silicon carbide, NBR - Cable length 20 m.
Seal lubrication oil Oil for food machinery and pharmaceutic use - Motor suitable operation with frequency converter.
110 350
100
90 300
ft
80
250
70
H MXS 3 200
m
50 MXS 5 MXS 9
150
40
30 100
20
50
10
0 0
0 m3/h 2 4 6 8 10 12
Q
0 l/min 50 100 150 200
72.986/1
381
MXS Multi-Stage Submersible Clean Water Pumps
in stainless steel
fM kg Cavo H07RN8-F
Pump
230V 230V 400V
mm MXS MXSM 1~ 3~ 3~
MXS 303 - MXSM 303 465 12,5 13,5 3G1 mm2 4G1 mm2 4G1 mm2
MXS 304 - MXSM 304 504 14,5 15,5 3G1 mm2 4G1 mm2 4G1 mm2
MXS 305 - MXSM 305 553 15 16,5 3G1 mm2 4G1 mm2 4G1 mm2
MXS 306 - MXSM 306 577 15,5 17 3G1 mm2 4G1 mm2 4G1 mm2
MXS 307 - MXSM 307 601 16 17,5 3G1 mm2 4G1 mm2 4G1 mm2
MXS 308 - MXSM 308 671 18,5 19,5 3G1,5 mm2 4G1 mm2 4G1 mm2
MXS 309 - MXSM 309 695 20,6 21,6 3G1,5 mm2 4G1,5 mm2 4G1 mm2
MXS 310 - MXSM 310 744 23 25,1 3G2,5 mm2 4G1,5 mm2 4G1 mm2
fM
MXS 503 - MXSM 503 480 14,5 15,5 3G1 mm2 4G1 mm2 4G1 mm2
MXS 504 - MXSM 504 529 15 16 3G1 mm2 4G1 mm2 4G1 mm2
MXS 505 - MXSM 505 553 16,1 17,6 3G1 mm2 4G1 mm2 4G1 mm2
MXS 506 - MXSM 506 622 17,5 19 3G1,5 mm2 4G1 mm2 4G1 mm2
MXS 507 - MXSM 507 671 20 21,5 3G2,5 mm2 4G1 mm2 4G1 mm2
MXS 508 - MXSM 508 695 20,5 22 3G2,5 mm2 4G1,5 mm2 4G1 mm2
MXS 509 - MXSM 509 744 23 24,5 3G2,5 mm2 4G1,5 mm2 4G1 mm2
MXS 510 768 27 4G1,5 mm2 4G1 mm2
MXS 903 - MXSM 903 523 16,1 17,6 3G1,5 mm2 4G1 mm2 4G1 mm2
MXS 904 - MXSM 904 573 18,2 19,7 3G1,5 mm2 4G1 mm2 4G1 mm2
MXS 905 - MXSM 905 653 19 22 3G2,5 mm2 4G1,5 mm2 4G1 mm2
Ø 133
MXS 906 - MXSM 906 708 23 26 3G2,5 mm2 4G1,5 mm2 4G1 mm2
MXSM ... CG MXS 907 738 26,3 4G2,5 mm2 4G1 mm2
With float switch pump MXS 908 793 27 4G2,5 mm2 4G1 mm2
(on demand) MXS 909 823 28,1 4G2,5 mm2 4G1,5 mm2
MXS 910 853 29,5 4G2,5 mm2 4G1,5 mm2
382
MXS Multi-Stage Submersible Clean Water Pumps
in stainless steel
40 50
η η
% %
30 40
0 Q m3/h 1 2 3 4 72.987.1
5 0 Q m3/h 2 4 6 72.988
8
0 Imp g.p.m. 10 20 30 40
120
110 MXS 9
910
100
909 300
90
H 908
m
ft
907
70
906 200
60
50 905
40 904
30 903 100
20
10
0 m3/h 2 4 6 8 10 12
Q
0 l/min 50 100 150 200
60
η
%
50
72.933
0 Q m3/h 2 4 6 8 10 12
383
MXS Multi-Stage Submersible Clean Water Pumps
in stainless steel
Features
PATENTED
Flexible Robust
Allows the inspection of the capacitor Its robust stainless steel
without disassembling the pump, through construction allows for the pump
the delivery casing. to be suspended from the delivery
pipe.
Reliable
The ball bearings and shaft are sized in
order to reduce stresses, guaranteeing
high reliability in any operating condition.
Low-Noise operation
The design of hydraulic parts, the
water-filled shroud around the
motor and the submerged opera-
tion ensures low noise operation.
Installation
Max. 1000 mm
max 20 m
Off
Off
0.5 m
min
140 mm
min 3.93.007/3
3.93.007/1 3.93.007/2
Pump in suspended position Pump with float switch (on demand) Installation example
384
03/2021
Construction
Submersible borehole pumps for 4” wells (DN 100 mm),
and 6” (DN 150 mm), with external jacket in stainless steel AISI
304 and impellers in Noryl.
Impellers
radial floating impellers 4SDP
radial impellers 6SDN 12, 16, 21
mixed flow impellers 6SD 18, 19, 20
Connection: screwed connection ISO 228.
Delivery casing with built-in non-return valve.
Applications
For water supply.
For civil and industrial applications.
For fire fighting applications.
For irrigation.
Operating conditions
Liquid temperature: - up to a 35 °C for 4” motors
- up to a 25 °C for 6” motors.
Max. sand quantity into the water: 150 g/m3 (300 g/m3 high
percentage of solids and sand).
Continuous duty.
The electropumps 4SDP 1,2,3,6 series comply with the European Regulation no.
547/2012. Operating conditions motor
Motor Max. Cooling: Max. Motor
Liquid minimum starts
Materials temperature flow velocity per hour P2
Pump 4CS-R 35 °C 0,08 m/s 20 all types
Components 4SDP 6SD, 6SDN 6CS-R 30 °C 0,1 m/s 15 4÷11 kW
External jacket Cr-Ni steel AISI 304 Cr-Ni steel AISI 304 0,2 m/s 15 13÷15 kW
Stage casing Cr-Ni steel AISI 304 Cr-Ni steel AISI 304 25 °C 0,2 m/s 15 18,5 kW
Diffuser Polycarbonate GFN2V* (NORYL®)* 0,2 m/s 13 22÷30 kW
Impeller GFN2V* (NORYL®)* GFN2V* (NORYL®)*
Wear ring - Cr-Ni steel AISI 304 Insulation class F for 4” motors, class E for 6” motors.
Shaft Cr-Ni steel AISI 304 Cr steel AISI 430 F Motor suitable operation with frequency converter .
Delivery casing Cr-Ni steel Bronze Protection IP 68.
Suction lantern AISI 304 G-Cu Sn 10 EN 1982
Bearing bush POM - POLYACETAL Rubber Special features on request
Strainer Cr-Ni steel AISI 304 Cr-Ni steel AISI 430 - Other voltages.
Screws Cr-Ni steel AISI 304 Cr-Ni steel AISI 304 - 60 Hz frequency.
* Trademark of General Electric - Other temperatures.
- Encapsulated motor FK series.
Motor
Components 4CS-R 6CS-R
External frame Cr-Ni steel AISI 304 Cr-Ni steel AISI 304 Designation
Motor flange Cast iron GJL 200 EN 1561 Cast iron GJL 200 EN 1561 4 SDP M 6 / 14
nickel-plated Ø of the well in inches
Shaft Cr-Ni-Mo steel Cr steel AISI 431
Series
AISI 316 (shaft end)
Single-phase motor (up to max. 2,2 kW)
Thrust bearing Oil wetted ball type Oscillation pads
Stage identification
Bearing bush Oil wetted ball type Graphite
Number of stages
385
SD Submersible borehole pumps for 4” and 6” wells
300
SD, SDP, SDN 1000
200
H
ft
6SDN 12
H 500
m 400
4SDP 4 6SD 20
100
4SDP 1 4SDP 2 4SDP 6 300
6SDN 6SDN
16 21 200
4SDP 3 4SDP 8
50
4SDP 16
40
6 6
30 SD SD 100
18 19
20
50
40
10
30
20
5
0,3 m3/h 0,5 1 2 3 4 5 10 20 30 40 50 60 70
5 Q l/min 10 20 30 40 50 100 150 200 300 400 500 1000
72.1002/N
386
4SDP Submersible borehole pumps for 4”
400 V
* Q n ≈ 2900 1/min
3~ (380-415) 1~ 230V Capacitor P1 P2
50 Hz m3/h 0 0,3 0,6 0,9 1,2 1,5 1,8 2,1 2,4 2,7 3 3,6 4,2 4,8 6
450 Vc
A A μF kW kW HP l/min 0 5 10 15 20 25 30 35 40 45 50 60 70 80 100
4SDP 1/10 1,2 4SDPM 1/10 3,2 16 0,71 0,37 0,5 67 63 55 46 33 18
4SDP 1/13 1,2 4SDPM 1/13 3,2 16 0,71 0,37 0,5 86 78 70 56 42 23
4SDP 1/19 1,5 4SDPM 1/19 4 25 0,91 0,55 0,75 126 118 105 86 60 30
4SDP 1/26 2,2 4SDPM 1/26 5,6 30 1,24 0,75 1 173 160 141 117 81 39
4SDP 1/38 2,8 4SDPM 1/38 8 40 1,71 1,1 1,5 253 234 208 169 117 52
4SDP 2/5 1,2 4SDPM 2/5 3,2 16 0,71 0,37 0,5 34 32 31 29 27 25 23 19 16
4SDP 2/7 1,2 4SDPM 2/7 3,2 16 0,71 0,37 0,5 46 43 42 39 36 33 29 26 22
4SDP 2/10 1,5 4SDPM 2/10 4 25 0,91 0,55 0,75 67 64 61 58 54 49 43 36 28
4SDP 2/14 2,2 4SDPM 2/14 5,6 30 1,24 0,75 1 92 86 83 79 74 67 60 52 42
4SDP 2/20 2,8 4SDPM 2/20 8 40 1,71 1,1 1,5 139 131 127 120 111 101 90 75 60
4SDP 2/28 3,7 4SDPM 2/28 10,8 60 2,33 1,5 2 H 190 178 172 163 153 141 126 108 89
4SDP 2/40 5,5 4SDPM 2/40 14,7 70 3,25 2,2 3 m 273 256 246 234 218 199 177 151 123
4SDP 3/5 1,2 4SDPM 3/5 3,2 16 0,71 0,37 0,5 34 32 31 30 29 27 25 23 18 11
4SDP 3/8 1,5 4SDPM 3/8 4 25 0,91 0,55 0,75 54 51 50 49 46 43 41 38 30 19
4SDP 3/11 2,2 4SDPM 3/11 5,6 30 1,24 0,75 1 72 68 66 64 61 58 54 49 38 26
4SDP 3/16 2,8 4SDPM 3/16 8 40 1,71 1,1 1,5 106 101 98 95 89 83 77 70 54 33
4SDP 3/21 3,7 4SDPM 3/21 10,8 60 2,33 1,5 2 142 135 132 127 122 11 5 108 100 79 49
4SDP 3/32 5,5 4SDPM 3/32 14,7 70 3,25 2,2 3 208 200 194 187 177 165 152 138 104 62
4SDP 4/5 1,2 4SDPM 4/5 3,2 16 0,71 0,37 0,5 33 29 28 27 26 24 21 18 13 3
4SDP 4/7 1,5 4SDPM 4/7 4 25 0,91 0,55 0,75 46 43 42 41 39 36 33 28 22 7
4SDP 4/9 2,2 4SDPM 4/9 5,6 30 1,24 0,75 1 59 55 54 52 51 47 43 37 28 10
4SDP 4/14 2,8 4SDPM 4/14 8 40 1,71 1,1 1,5 93 87 86 83 81 76 68 58 47 20
4SDP 4/18 3,7 4SDPM 4/18 10,8 60 2,33 1,5 2 120 113 111 108 105 98 88 75 60 25
4SDP 4/27 5,5 4SDPM 4/27 14,7 70 3,25 2,2 3 175 164 161 157 152 141 127 109 87 35
4SDP 4/35 7,4 3 4 228 212 208 203 197 184 166 145 11 9 46
4SDP 4/44 9,4 4 5,5 282 261 255 249 241 223 201 173 140 52
4SDP 4/48 9,4 4 5,5 309 289 283 276 267 248 225 197 162 73
400 V
* Q n ≈ 2900 1/min
3~ (380-415)
1~ 230V Capacitor P1 P2
50 Hz m /h
3
0 3 3,6 4,2 4,8 5,4 6 7,2 8,4 9,6 10,8 12 15,6 18 21,6 24
450 Vc
A A μF kW kW HP l/min 0 50 60 70 80 90 100 120 140 160 180 200 260 300 360 400
4SDP 6/7 2,2 4SDPM 6/7 5,6 30 1,24 0,75 1 42 36 34 32 30 28 25 19 11
4SDP 6/10 2,8 4SDPM 6/10 8 40 1,71 1,1 1,5 62 53 51 48 45 41 38 29 18
4SDP 6/14 3,7 4SDPM 6/14 10,8 60 2,33 1,5 2 90 77 74 71 68 63 59 46 28
4SDP 6/20 5,5 4SDPM 6/20 14,7 70 3,25 2,2 3 125 107 102 97 92 86 80 62 40
4SDP 6/27 7,4 3 4 169 145 139 131 123 115 107 84 55
4SDP 6/34 9,4 4 5,5 208 178 170 162 153 143 132 103 66
4SDP 6/36 9,4 4 5,5 221 190 181 173 164 154 143 11 2 72
4SDP 6/49 13 5,5 7,5 302 257 246 234 222 209 193 151 96
4SDP 8/4 2,2 4SDPM 8/4 5,6 30 1,24 0,75 1 26 23 22 21 20 18 16 12 9
4SDP 8/6 2,8 4SDPM 8/6 8 40 1,71 1,1 1,5 38 35 34 33 31 28 24 19 14
4SDP 8/8 3,7 4SDPM 8/8 10,8 60 2,33 1,5 2 52 47 45 44 41 37 31 25 18
4SDP 8/13 5,5 4SDPM 8/13 14,7 70 3,25 2,2 3 82 75 73 71 66 59 50 40 30
4SDP 8/17 7,4 3 4
H 108 98 96 94 87 79 70 58 46
m
4SDP 8/21 9,4 4 5,5 132 117 114 111 103 93 82 68 52
4SDP 8/23 9,4 4 5,5 148 134 131 127 11 8 108 95 79 60
4SDP 8/32 13 5,5 7,5 202 182 178 172 160 143 125 105 80
4SDP 16/8 5,5 4SDPM 16/8 14,7 70 3,25 2,2 3 49 39 38 36 34 28 23 15 9
4SDP 16/11 7,4 3 4 67 55 53 50 48 39 33 23 16
4SDP 16/13 9,4 4 5,5 79 65 62 59 56 47 40 28 20
4SDP 16/15 9,4 4 5,5 93 76 73 70 66 55 47 34 25
4SDP 16/20 13 5,5 7,5 122 99 95 90 86 72 61 44 32
P1 Max. power input P2 Rated motor power output * Only for single-phase motor 230 V - 50 Hz (on request) Tolerances according to UNI EN ISO 9906:2012
387
4SDP 1 Submersible borehole pumps for 4” wells
0 1 2 Imp. g.p.m. 4 5 6 7
250
800
38
4SDP 1 Rp 1 1/4"
700
200
600
26
H
150 ft
f
H 19 400
m
100
fM
300
13
10
200
50
100
0 0
0 m3/h 0.4 0.8 1.2 1.6 2
0
Q l/min 10 20 30
3.93.063.2N
0 l/s 0.1 0.2 0.3 0.4 0.5
50 0,06 Ø 96
40 η kW/st
98
Ø
η% 0,04
20 kW/st 0,03
10 0,02
0 0,01
0 Q 3
m /h 0.4 0.8 1.2 1.6 72.1007 2
400 V
* Q n≈
n ≈2900
2900 rpm
1/min
4SDP 4SDPM
3~ (380-415) 1~ 230V Capacitor P1 P2
50 Hz m3/h 0 0,3 0,6 0,9 1,2 1,5 f fM fM
450 Vc
A A μ F kW kW HP l/min 0 5 10 15 20 25 mm mm kg mm kg
4SDP 1/10C 1,2 4SDPM 1/10C 3,2 16 0,71 0,37 0,5 67 63 55 46 33 18 324 651 11 651 10,9
4SDP 1/13C 1.2 4SDPM 1/13C 3,2 16 0,71 0,37 0,5 86 78 70 56 42 23 377 704 11,4 704 11,3
4SDP 1/19C 1.5 4SDPM 1/19C 4 25 0,91 0,55 0,75 126 118 105 86 60 30 481 808 12,4 843 14,1
4SDP 1/26C 2.2 4SDPM 1/26C 5,6 30 1,24 0,75 1 173 160 141 117 81 39 642 989 14,5 1004 15,2
H m
4SDP 1/38C 2.8 4SDPM 1/38C 8 40 1,71 1,1 1,5 253 234 208 169 117 52 864 1226 18,7 1266 19,9
P1 Max. power input P2 Rated motor power output * Only for single-phase motor 230 V - 50 Hz (on request) Tolerances according to UNI EN ISO 9906:2012
388
4SDP 2 Submersible borehole pumps for 4” wells
0 Imp. g.p.m 3 4 5 6 7 8 9 10 11 12
300
40
800
H
ft
200
28 600
f
H
m 500
20
400 fM
100
14 300
10
200
7
5
100
0 0
0 m3/h 1 2 3 3,6
Q
0 l/min 10 20 30 40 50 60
3.93.063.2N
0 l/s 0,2 0,3 0,4 0,5 0,6 0,7 0,8 0,9 1,0
60
72.1173
0,10 Ø 96
η
50 kW/st 98
Ø
40 kW/st 0,06
30 0,04
η
0,02
%
10 0
0 Q m3/h 1 2 3 3,6
400 V
* Q n ≈n2900 rpm
≈ 2900 1/min
4SDP 4SDPM
3~ (380-415) 1~ 230V Capacitor P1 P2
50 Hz m3/h 0 0,9 1,2 1,5 1,8 2,1 2,4 2,7 3 f fM fM
450 Vc
A A μ F kW kW HP l/min 0 15 20 25 30 35 40 45 50 mm mm kg mm kg
4SDP 2/5C 1,2 4SDPM 2/5C 3,2 16 0,71 0,37 0,5 34 32 31 29 27 25 23 19 16 236 563 10,2 563 10,1
4SDP 2/7C 1,2 4SDPM 2/7C 3,2 16 0,71 0,37 0,5 46 43 42 39 36 33 29 26 22 271 598 10,5 598 10,4
4SDP 2/10C 1,5 4SDPM 2/10C 4 25 0,91 0,55 0,75 67 64 61 58 54 49 43 36 28 324 651 11 686 12,7
4SDP 2/14C 2,2 4SDPM 2/14C 5,6 30 1,24 0,75 1 92 86 83 79 74 67 60 52 42 394 741 12,6 756 13,3
H m
4SDP 2/20C 2,8 4SDPM 2/20C 8 40 1,71 1,1 1,5 139 131 127 120 111 101 90 75 60 499 861 14,4 901 15,6
4SDP 2/28C 3,5 4SDPM 2/28C 10,8 60 2,33 1,5 2 190 178 172 163 153 141 126 108 89 680 1082 17,7 1127 19,3
4SDP 2/40C 5,5 4SDPM 2/40C 14,7 70 3,25 2,2 3 273 256 246 234 218 199 177 151 123 885 1287 21 1402 25
P1 Max. power input P2 Rated motor power output * Only for single-phase motor 230 V - 50 Hz (on request) Tolerances according to UNI EN ISO 9906:2012
389
4SDP 3 Submersible borehole pumps for 4” wells
900 Rp 1 1/4"
4SDP 3
800
700
32 H
200
ft
600
f
H
m 500
21
400 fM
16
100
300
11
200
8
5
100
0 0
0 m3/h 1 2 3 4 5
Q
0 l/min 20 30 40 50 60 70 80
3.93.063.2N
30 0,04
η
0,02
%
10 0
0 Q m3/h 1 2 3 4 5
400 V
* Q n≈
n ≈2900
2900rpm
1/min
4SDP 4SDPM
3~ (380-415) 1~ 230V Capacitor P1 P2
50 Hz m3/h 0 1,2 1,5 1,8 2,1 2,4 2,7 3 3,6 4,2 f fM fM
450 Vc
A A μ F kW kW HP l/min 0 20 25 30 35 40 45 50 60 70 mm mm kg mm kg
4SDP 3/5C 1,2 4SDPM 3/5C 3,2 16 0,71 0,37 0,5 34 32 31 30 29 27 25 23 18 11 236 563 10,2 563 10,1
4SDP 3/8C 1,5 4SDPM 3/8C 4 25 0,91 0,55 0,75 54 51 50 49 46 43 41 38 30 19 289 616 10,6 651 12,3
4SDP 3/11C 2,2 4SDPM 3/11C 5,6 30 1,24 0,75 1 72 68 66 64 61 58 54 49 38 26 342 689 12,1 704 12,8
4SDP 3/16C 2,8 4SDPM 3/16C 8 40 1,71 1,1 1,5 106 101 98 95 89 83 77 70 54 33 430 792 13,7 832 14,9
H m
4SDP 3/21C 3,7 4SDPM 3/21C 10,8 60 2,33 1,5 2 142 135 132 127 122 115 108 100 79 49 519 921 15,8 966 17,4
4SDP 3/32C 5,5 4SDPM 3/32C 14,7 70 3,25 2,2 3 208 200 194 187 177 165 152 138 104 62 787 1189 19,8 1304 23,8
P1 Max. power input P2 Rated motor power output * Only for single-phase motor 230 V - 50 Hz (on request) Tolerances according to UNI EN ISO 9906:2012
390
4SDP 4 Submersible borehole pumps for 4” wells
0 Imp. g.p.m 4 6 8 10 12 14 16 18 20 22
340
1100
Rp 1 1/4"
300 4SDP 4 1000
48
900
44 H
H ft
m 800
35 700
200 f
600
27
500
fM
18 400
100
14 300
9 200
7
5 100
0 0
0 m3/h 1 2 3 4 5 6
Q
0 l/min 20 30 40 50 60 70 80 90 100
3.93.063.2N
20 0,04
0 0
0 Q m3/h 1 2 3 4 5 6
400 V
* Q n n≈≈2900
2900 rpm
1/min
(380-415) 1~ 230V Capacitor P1 P2 4SDP 4SDPM
3~
50 Hz m3/h 0 1,5 1,8 2,1 2,4 3 3,6 4,2 4,8 6 f fM fM
450 Vc
A A μ F kW kW HP l/min 0 25 30 35 40 50 60 70 80 100 mm mm kg mm kg
4SDP 4/5C 1,2 4SDPM 4/5C 3,2 16 0,71 0,37 0,5 33 29 28 27 26 24 21 18 13 3 257 584 10,4 584 10,3
4SDP 4/7C 1,5 4SDPM 4/7C 4 25 0,91 0,55 0,75 46 43 42 41 39 36 33 28 22 7 301 628 10,7 663 12,4
4SDP 4/9C 2,2 4SDPM 4/9C 5,6 30 1,24 0,75 1 59 55 54 52 51 47 43 37 28 10 344 691 12 706 12,7
4SDP 4/14C 2,8 4SDPM 4/14C 8 40 1,71 1,1 1,5 93 87 86 83 81 76 68 58 47 20 452 814 13,6 854 14,8
H m
4SDP 4/18C 3,7 4SDPM 4/18C 10,8 60 2,33 1,5 2 120 113 111 108 105 98 88 75 60 25 538 940 15,5 985 17,1
4SDP 4/27C 5,5 4SDPM 4/27C 14,7 70 3,25 2,2 3 175 164 161 157 152 141 127 109 87 35 805 1207 18,9 1322 22,9
4SDP 4/35C 7,4 3 4 228 212 208 203 197 184 166 145 119 46 972 1453 23,8
4SDP 4/44C 9,4 4 5,5 282 261 255 249 241 223 201 173 140 52 1166 1712 28,5
4SDP 4/48C 9,4 4 5,5 309 289 283 276 267 248 225 197 162 73 1291 1837 29,1
P1 Max. power input P2 Rated motor power output * Only for single-phase motor 230 V - 50 Hz (on request) Tolerances according to UNI EN ISO 9906:2012
391
4SDP 6 Submersible borehole pumps for 4” wells
0 Imp. g.p.m 8 12 16 20 24 28
340
1100
Rp 2"
300
4SDP 6 1000
900
49 H
H ft
m 800
700
200 f
36
34 600
27 500
fM
400
20
100
300
14
10 200
7
100
0 0
0 m3/h 1 2 3 4 5 6 7 8
Q
0 l/min 20 40 60 80 100 120 140
3.93.063.2N
η kW/st
60 98
0,16 Ø
η
%
40 0,12
kW/st
20 0,08
0 0,04
0 Q m3/h 1 2 3 4 5 6 7 8
400 V
* Q nn≈≈2900
2900 rpm
1/min
4SDP 4SDPM
3~ (380-415) 1~ 230V Capacitor P1 P2
50 Hz m3/h 0 3 3,6 4,2 4,8 5,4 6 7,2 8,4 f fM fM
450 Vc
A A μ F kW kW HP l/min 0 50 60 70 80 90 100 120 140 mm mm kg mm kg
4SDP 6/7C 2,2 4SDPM 6/7C 5,6 30 1,24 0,75 1 42 36 34 32 30 28 25 19 11 390 737 12,4 752 13,1
4SDP 6/10C 2,8 4SDPM 6/10C 8 40 1,71 1,1 1,5 62 53 51 48 45 41 38 29 18 483 845 14,1 885 15,3
4SDP 6/14C 3,7 4SDPM 6/14C 10,8 60 2,33 1,5 2 90 77 74 71 68 63 59 46 28 607 1009 16,5 1054 18,1
4SDP 6/20C 5,5 4SDPM 6/20C 14,7 70 3,25 2,2 3 125 107 102 97 92 86 80 62 40 831 1233 19,2 1348 23,2
H m
4SDP 6/27C 7,4 3 4 169 145 139 131 123 115 107 84 55 1086 1567 25,5
4SDP 6/34C 9,4 4 5,5 208 178 170 162 153 143 132 103 66 1295 1841 30,8
4SDP 6/36C 9,4 4 5,5 221 190 181 173 164 154 143 112 72 1356 1902 31,4
4SDP 6/49C 13 5,5 7,5 302 257 246 234 222 209 193 151 96 1840 2486 39,9
P1 Max. power input P2 Rated motor power output * Only for single-phase motor 230 V - 50 Hz (on request) Tolerances according to UNI EN ISO 9906:2012
392
4SDP 8 Submersible borehole pumps for 4” wells
0 Imp. g.p.m 4 6 8 10 12 14 16 18 20 22
250
800
Rp 2"
4SDP 8
Pumps for specific applications with 700
high percentage of solids and sand
200
32 600
H
150 ft f
23
H 21 400
m
100 17 fM
300
13
200
50 8
6
100
4
0 0
0 m3/h 2 4 6 8 10 12
Q
0 l/min 40 60 80 100 120 140 160 180 200
3.93.063.2N
0 l/s 1 2,0 3
80
72.1175
0,24 Ø 96
η kW/st
60 0,20 98
Ø
η
% kW/st
40 0,16
20 0,12
0 0,08
0 Q m3/h 2 4 6 8 10 12
400 V
* Q n ≈ n2900 rpm
≈ 2900 1/min
(380-415) 230V Capacitor P1 P2 4SDP 4SDPM
3~ 1~
50 Hz m3/h 0 4,8 5,4 6 7,2 8,4 9,6 10,8 12 f fM fM
450 Vc
A A μ F kW kW HP l/min 0 80 90 100 120 140 160 180 200 mm mm kg mm kg
4SDP 8/4C 2,2 4SDPM 8/4C 5,6 30 1,24 0,75 1 26 23 22 21 20 18 16 12 9 294 641 11,5 656 12,2
4SDP 8/6C 2,8 4SDPM 8/6C 8 40 1,71 1,1 1,5 38 35 34 33 31 28 24 19 14 356 718 12,9 758 14,1
4SDP 8/8C 3,7 4SDPM 8/8C 10,8 60 2,33 1,5 2 52 47 45 44 41 37 31 25 18 418 820 14,8 865 16,4
4SDP 8/13C 5,5 4SDPM 8/13C 14,7 70 3,25 2,2 3 82 75 73 71 66 59 50 40 30 573 975 17,2 1090 21,2
H m
4SDP 8/17C 7,4 3 4 108 98 96 94 87 79 70 58 46 697 1178 21,5
4SDP 8/21C 9,4 4 5,5 132 117 114 111 103 93 82 68 52 859 1405 26
4SDP 8/23C 9,4 4 5,5 148 134 131 127 118 108 95 79 60 959 1505 27,6
4SDP 8/32C 13 5,5 7,5 202 182 178 172 160 143 125 105 80 1276 1922 35
P1 Max. power input P2 Rated motor power output * Only for single-phase motor 230 V - 50 Hz (on request) Tolerances according to UNI EN ISO 9906:2012
393
4SDP 16 Submersible borehole pumps for 4” wells
0 Imp. g.p.m 8 12 16 20 24 28 32 36 40 44
150
450 Rp 2"
4SDP 16
Pumps for specific applications with
high percentage of solids and sand
400
H
ft
100 20
300
f
H 15
m 250
13
200 fM
11
50
150
8
100
50
0 0
0 m3/h 4 8 12 16 20 24
Q
0 l/min 80 120 160 200 240 280 320 360 400
3.93.063.2N
0 l/s 2 4,0 6
80
72.1175
0,5 Ø 96
η kW/st
60 0,4 98
Ø
η
%
40 0,3
kW/st
20 0,2
0 0,1
0 Q m3/h 4 8 12 16 20 24
400 V
* Q n≈ 29001/min
≈ 2900 rpm
4SDP 4SDPM
3~ (380-415) 1~ 230V Capacitor P1 P2
50 Hz m3/h 0 8,4 9,6 10,8 12 13,2 15,6 18 21,6 24 f fM fM
450 Vc
A A μ F kW kW HP l/min 0 140 160 180 200 220 260 300 360 400 mm mm kg mm kg
4SDP 16/8C 5,5 4SDPM 16/8C 14,7 70 3,25 2,2 3 49 39 38 36 34 32 28 23 15 9 676 1078 18 1193 22
4SDP 16/11C 7,4 3 4 67 55 53 50 48 45 39 33 23 16 880 1361 23
4SDP 16/13C 9,4 4 5,5 79 65 62 59 56 53 47 40 28 20 1013 1559 27,5
4SDP 16/15C 9,4 4 5,5 H m 93 76 73 70 66 62 55 47 34 25 1149 1695 28,7
4SDP 16/20C 13 5,5 7,5 122 99 95 90 86 81 72 61 44 32 1489 2135 36,5
P1 Max. power input P2 Rated motor power output * Only for single-phase motor 230 V - 50 Hz (on request) Tolerances according to UNI EN ISO 9906:2012
394
6SDN 12 Submersible borehole pumps for 6” wells
0 20 Imp. g.p.m. 40 60
400
DN
6SDN 12 1200
1000
300
29
H
ft
24 800
200 19 f
600
14
400
10
100
200
3.93.110.2
0 0 7 1
0 m 3/h 6 12 18 20 14 15
Ø Ø
0 Q l/min 100 200 300
0 l/s 1 2 3 4 5
80
0.5
η%
60
0.4 η%
kW/st
kW/st 40
0.3
20
0.2
0
0 Q m 3/h 6 12 72.1150 18 20
Q n≈ 2900 rpm
3~ P2
m /h
3
2 4 6 8 10 12 14 16 18 DN f
kW HP l/min 33,3 66,6 100 133,3 166,6 200 233 266 300 mm kg
P2 Rated motor power output (...) FK motor rated power output H Total head in m Tolerances according to UNI EN ISO 9906:2012
395
6SDN 16 Submersible borehole pumps for 6” wells
0 20 40 Imp. g.p.m. 80
400
DN
6SDN 16 1200
Pumps for specific applications with
H 33
high percentage of solids and sand
m
1000
300
27 H
ft
800
23
20
200 f
600
17
13
400
10
100
7
200
3.93.110.2
7 1
0 0 14 15
0 m 3/h 5 10 15 20 25 Ø Ø
0 Q l/min 100 200 300 400
0 l/s 2 3 4 5 6
80
0.6
η%
60
0.5 η%
kW/st
kW/st 40
0.4
20
0.3
0
0 Q m 3/h 5 10 15 20 72.1126 25
Q n≈ 2900 rpm
3~ P2
m /h3
3 6 9 12 15 18 21 25 DN f
P2 Rated motor power output (...) FK motor rated power output H Total head in m Tolerances according to UNI EN ISO 9906:2012
396
6SDN 21 Submersible borehole pumps for 6” wells
300 28
6SDN 21 1000
Pumps for specific applications with
high percentage of solids and sand
H
m 23
800
H
19 ft
200
600
16
f
14
11 400
100 9
5 200
3.93.110.2
0 0 7 1
14 15
0 m 3/h 10 20 30 40 Ø Ø
0 Q l/min 200 400 600
0 l/s 2 4 6 8 10
80
1.0 70
η%
kW/st η%
0.8 50
kW/st
40
0.6 30
20
0.4 10
0 Q m 3/h 10 20 30 72.1142 40
Q n≈ 2900 rpm
3~ P2
m3/h 5 9 12 15 18 21 24 27 30 33 DN f
kW HP l/min 83,3 150 200 250 300 350 400 450 500 550 mm kg
6SDN 21/5 4 5,5 54 51 48,5 46,5 45 41,5 36 29 21,5 11,5 565 13,3
6SDN 21/7 5,5 7,5 75,5 71,5 68 65 62,5 58 50 41 30 16 660 14,5
6SDN 21/9 7,5 10 97 92 87,5 83,5 80,5 74,5 64,5 53 38,5 21 755 15,7
6SDN 21/11 9,2 12,5 119 112 107 102 99 91 79 64 47 25,5 850 16,9
H G3
6SDN 21/14 11 15 151 143 136 130 125 116 100 81,5 60 32,5 ISO 228 990 18,7
m
6SDN 21/16 13 (15) 17,5 (20) 173 163 155 149 143 132 114 93 69 37 1085 19,9
6SDN 21/19 15 20 205 194 185 176 170 157 136 111 81,5 44 1225 21,7
6SDN 21/23 18,5 25 249 235 224 213 206 190 164 134 99 53 1480 24,5
6SDN 21/28 22 30 303 286 272 260 251 231 200 163 120 64,5 1710 27,5
P2 Rated motor power output (...) FK motor rated power output H Total head in m Tolerances according to UNI EN ISO 9906:2012
397
6SD 18 Submersible borehole pumps for 6” wells
H
6SD 18 H
Pumps for specific applications with ft
m
high percentage of solids and sand
16 700 CALPEDA
200
600
13
f
150 500
11
9 400
8
100
7
300
3.93.110.21
6
5
200 1 5
15 15
4 Ø Ø
50
3
100
0 0
0 m 3/h 10 20 30 40 50
0
Q l/min 200 400 600 800
0 l/s 4 6 8 10 12 72.301
Q n≈ 2900 rpm
3~ P2
m /h3
6 12 18 24 30 36 42 45 DN f
P2 Rated motor power output (...) FK motor rated power output H Total head in m Tolerances according to UNI EN ISO 9906:2012
398
6SD 19 Submersible borehole pumps for 6” wells
H 6SD 19 H
m ft
Pumps for specific applications with
high percentage of solids and sand
CALPEDA
250 17
800
200
13
f
600
11
150
8 400
7
100 3.93.110.21
5 1 5
15 15
Ø Ø
4 200
50
3
0 0
0 m 3/h 10 20 30 40 50 60
0
Q l/min 200 400 600 800 1000
0 l/s 5 10 15 72.302
Q n≈ 2900 rpm
3~ P2
m3/h 6 12 18 24 30 36 42 48 54 DN f
kW HP l/min 100 200 300 400 500 600 700 800 900 mm kg
P2 Rated motor power output (...) FK motor rated power output H Total head in m Tolerances according to UNI EN ISO 9906:2012
399
6SD 20 Submersible borehole pumps for 6” wells
200 13
6SD 20 H
Pumps for specific applications with ft
high percentage of solids and sand
CALPEDA
H 600
m
10 500
150
9
f
8 400
100
6 300
5
3.93.110.21
4
200
1 5
50 15 15
3 Ø Ø
2
100
0 0
0 m 3/h 10 20 30 40 50 60
0
Q l/min 200 400 600 800 1000
0 l/s 5 10 15 72.299
Q n≈ 2900 rpm
3~ P2
m /h
3
12 18 24 30 36 42 48 54 57 DN f
kW HP l/min 200 300 400 500 600 700 800 900 950 mm kg
P2 Rated motor power output (...) FK motor rated power output H Total head in m Tolerances according to UNI EN ISO 9906:2012
400
401
03/2021
Construction
Submersible borehole pumps for 6” wells (DN 150 mm) and 8”
(DN 200 mm).
6SDX 16,28,45,60 - 8SDX 78,97: with external jacket and stages
in stainless steel AISI 304.
6SDXL 18,30,46,65 - 8SDXL 78,97: with external jacket and sta-
ges in stainless steel AISI 316.
Impellers
Radial impellers 6SDXL 18
Mixed flow impellers 6SDX 16-28-45-60, 8SDX 78-97
6SDXL 30-46-65, 8SDXL 78-97
Connection: Screwed connection Rp 2” 1/2, 3”, 4”, 5”
Delivery casing with built-in non-return valve.
Applications
For water supply.
For civil and industrial applications.
For fire fighting applications.
For irrigation.
Operating conditions
Liquid temperature up to: 30 °C for 6SDX
60 °C for 8SDX
90 °C for SDXL.
Max. sand quantity into the water: 50 g/m3 per 6SDX
100 g/m3 per 8SDX
100 g/m3 per SDXL
Continuous duty.
402
SDX Submersible borehole pumps for 6” and 8” wells
300 1000
H
ft
200
8SDX 78
H 500
m
6SDX16 400
100 8
SDX 300
6SDX 28
97
6SDX 45 200
50 6SDX
60
40
30 100
20
50
40
10
30
20
5
4
3 m3 /h 4 5 10 20 30 40 50 100 150
Q l/min
50 100 150 200 300 400 500 1000 2000
72.1161_10
300 1000
200
6SDXL 18
H 500
m
6SDXL 30 400
8
100 SDXL
8 300
6SDXL 46 78
SDXL
6SDXL 65
97 200
50
40
30 100
20
50
40
10
30
20
5
5 m 3/h 10 20 30 40 50 100 150
Q l/min
100 150 200 300 400 500 1000 2000
72.1161_10
403
6SDX 16 Submersible borehole pumps for 6” wells
Characteristic curves
50 75 100
33
350 32
31 6SDX 16
30
29
28
1000
300
27
26
H
m 25 ft
24
23
250
22 800
21
20
19
200 18
17
16 600
15
14
150
13
12
11
400
10
100 9
8
7
6
5 200
50 4
3
2
1
0 0
0 m3/h 4 6 8 10 12 14 16 18 20 22 24
0
Q
l/min 100 200 300 400
80 1.6
60 1.2
% kW/st
40 0.8
kW/st
20 0.4
0 0
8
6
NPSH
m
4
0
0 Q m3/h 4 6 8 10 12 14 16 18 20 22 24
404
6SDX 16 Submersible borehole pumps for 6” wells
DN
Q n ≈ 2900 1/min
3~ P2 Motore
m3/h 0 3 6 9 12 15 18 21 23 DN f
Ø
kW HP l/min 0 50 100 150 200 250 300 350 383 mm mm kg
P2 Rated motor power output (...) FK motor rated power output H Total head in m Tolerances according to UNI EN ISO 9906:2012
405
6SDX 28 Submersible borehole pumps for 6” wells
Characteristic curves
35
34 6SDX 28
33 1200
350 32
31
H 30
m 29
28
1000
300 27
26
25 ft
24
250 23
22 800
21
20
19
200 18
17
600
16
15
14
150 500
13
12
11 400
10
9
100
8 300
7
6
5 200
50 4
3
100
2
1
0 0
0 m3/h 6 12 18 24 30 36 42
Q
0 l/min 100 200 300 400 500 600 700
100 2
80 1.6
% kW/st
60 1.2
kW/st
40 0.8
20 0.4
0 0
10
8
NPSH
m 6
0
0 Q m3/h 6 12 18 24 30 36 42
406
6SDX 28 Submersible borehole pumps for 6” wells
DN
Q n ≈29001/min
3~ P2 Motore
m3/h 0 6 9 12 15 18 21 24 27 30 33 36 39 DN f
Ø
kW HP l/min 0 100 150 200 250 300 350 400 450 500 550 600 650 mm mm kg
P2 Rated motor power output (...) FK motor rated power output H Total head in m Tolerances according to UNI EN ISO 9906:2012
407
6SDX 45 Submersible borehole pumps for 6” wells
Characteristic curves
24 1100
6SDX 45
23
22 1000
300
21
H
20 900
m
19
250 18
800
17
ft
16
700
15
200
14
600
13
12
11 500
150
10
9
400
8
100 7
300
6
5
200
4
50
3
2 100
0 0
0 m3/h 10 20 30 40 50 60
Q
0 l/min 200 400 600 800 1000
80 2.2
60 1.8
% kW/st
kW/st
40 1.4
20 1
0 0.6
8
6
NPSH
m
4
0
0 Q m3/h 10 20 30 40 50 60
408
6SDX 45 Submersible borehole pumps for 6” wells
DN
Q n ≈29001/min
3~ P2 Motore
m3/h 0 12 15 18 21 24 27 30 36 42 48 54 60 DN f
Ø
kW HP l/min 0 200 250 300 350 400 450 500 600 700 800 900 1000 mm mm kg
131 (4”)
142 (6”)
142 (6”)
P2 Rated motor power output (...) FK motor rated power output H Total head in m Tolerances according to UNI EN ISO 9906:2012
409
6SDX 60 Submersible borehole pumps for 6” wells
Characteristic curves
1100
6SDX 60
22
1000
300
21
H 20
m 900
19
18
250
17 800
ft
16
15 700
200 14
13 600
12
11
150 500
10
9
400
8
100 7
300
6
4 200
50
3
2 100
0 0
0 m3/h 10 20 30 40 50 60 70 80
Q
0 l/min 200 400 600 800 1000 1200
80 2.2
60 kW/st 1.8
% kW/st
40 1.4
20 1
0 0.6
8
6
NPSH
m
4
0
0 Q m3/h 10 20 30 40 50 60 70 80
410
6SDX 60 Submersible borehole pumps for 6” wells
DN
Q n ≈29001/min
3~ P2 Motore
m3/h 0 18 21 24 30 36 42 48 54 60 66 72 78 DN f
Ø
kW HP l/min 0 300 350 400 500 600 700 800 900 1000 1100 1200 1300 mm mm kg
131 (4”)
142 (6”)
142 (6”)
P2 Rated motor power output (...) FK motor rated power output H Total head in m Tolerances according to UNI EN ISO 9906:2012
411
6SDXL 18 Submersible borehole pumps for 6” wells
Characteristic curves
60 2200
59
58 6SDXL 18
57
56
55
54 2000
600
53
52
51
50
49 1800
48
47
46
500 45
44 1600
43
42
41 ft
40
39
38 1400
37
400 36
35
34
33 1200
32
31
30
29
28
300 27 1000
26
25
24
H 23
m 22 800
21
20
19
200 18
17
16 600
15
14
13
12
11 400
10
100 9
8
7
6
200
0 0
0 Q m3/h 5 10 15 20 25 30
1,0 80
η (%)
0,8 60
kW/st η (%)
kW/st
0,6 40
0,4 20
0,2 0
0 Q m3/h
72.1163
5 10 15 20 25 30
412
6SDXL 18 Submersible borehole pumps for 6” wells
DN
Q nn≈≈2900
2900rpm
1/min
3~ P2 Motore
m3/h 0 8 10 12 15 18 21 24 27 DN f
CS-R FK
kW HP l/min 0 133 167 200 250 300 350 400 450 mm mm mm kg
6SDXL 18/6 4 5,5 70 66,4 64 62 57,6 51,6 43,2 32,9 20,5 494 12,5
6SDXL 18/7 5,5 7,5 81,7 77,5 74,7 72,3 67,2 60,2 50,4 38,4 23,9 532 13,5
6SDXL 18/8 5,5 7,5 93,3 88,5 85,3 82,7 76,8 68,8 57,6 43,9 27,4 569 14,3
6SDXL 18/9 5,5 7,5 105 99,6 96 93 86,4 77,4 64,8 49,4 30,8 607 15
6SDXL 18/10 7,5 10 117 111 107 103 96 86 72,0 54,9 34,2 644 16
6SDXL 18/11 7,5 10 128 122 117 114 106 94,6 79,2 60,4 37,6 682 17
6SDXL 18/12 7,5 10 140 133 128 124 115 103 86,4 65,8 41,0 719 17,5
6SDXL 18/13 9,2 12,5 152 144 139 134 125 112 93,6 71,3 44,5 757 18,5 f
6SDXL 18/14 9,2 12,5 163 155 149 145 134 120 101 76,8 47,9 794 19,3
6SDXL 18/15 9,2 12,5 175 166 160 155 144 129 108 82,3 51,3 832 20
6SDXL 18/16 11 15 187 177 171 165 154 138 115 87,8 54,7 869 21
6SDXL 18/17 11 15 198 188 181 176 163 146 122 93,3 58,1 907 22
6SDXL 18/18 11 15 210 199 192 186 173 155 130 98,8 61,6 944 22,5
6SDXL 18/19 13 (15) 17,5 (20) 222 210 203 196 182 163 137 104 65,0 982 23,5
6SDXL 18/20 13 (15) 17,5 (20) 233 221 213 207 192 172 144 110 68,4 1019 24
6SDXL 18/21 13 (15) 17,5 (20) 245 232 224 217 202 181 151 115 71,8 1057 25
6SDXL 18/22 15 20 257 243 235 227 211 189 158 121 75,2 1094 26
6SDXL 18/23 15 20 268 254 245 238 221 198 166 126 78,7 1132 26,5
6SDXL 18/24 15 20 280 266 256 248 230 206 173 132 82,1 1169 27,5
6SDXL 18/25 18,5 25 292 277 267 258 240 215 180 137 85,5 1207 28,3 Ø 135 6"
6SDXL 18/26 18,5 25 303 288 277 269 250 224 187 143 88,9 1244 29
6SDXL 18/27 18,5 25 315 299 288 279 259 232 194 148 92,3 1282 31
6SDXL 18/28 18,5 25 327 310 299 289 269 241 202 154 95,8 1319 31 7
6SDXL 18/29 18,5 25 338 321 309 300 278 249 209 159 99,2 1356 31,5 14
Ø
6SDXL 18/30 18,5 25 350 332 320 310 288 258 216 165 103 1394 32,5
6SDXL 18/31 22 30 362 343 331 320 298 267 223 170 106 Rp 145 137 1431 33,3
6SDXL 18/32 22 30 373 354 342 331 307 275 230 176 109 2”1/2 6" 6" 1469 34
6SDXL 18/33 22 30 H 385 365 352 341 317 284 238 181 113 1506 35
6SDXL 18/34 22 30 m 397 376 363 351 326 292 245 187 116 1544 35,7
6SDXL 18/35 22 30 408 387 373 362 336 301 252 192 120 1581 36,3
6SDXL 18/36 22 30 420 398 384 372 346 310 259 198 123 1619 37 4
14
6SDXL 18/37 26 (30) 35 (40) 432 409 395 382 355 318 266 203 127 1656 38,4 Ø
6SDXL 18/38 26 (30) 35 (40) 443 420 405 393 365 327 274 209 130 1694 39,8
6SDXL 18/39 26 (30) 35 (40) 455 432 416 403 374 335 281 214 133 1731 40
6SDXL 18/40 26 (30) 35 (40) 467 443 427 413 384 344 288 220 137 1769 40,5
6SDXL 18/41 26 (30) 35 (40) 478 454 437 424 394 353 295 225 140 1806 41,8
6SDXL 18/42 26 (30) 35 (40) 490 465 448 434 403 361 302 230 144 1844 43
6SDXL 18/43 30 40 502 476 459 444 413 370 310 236 147 1881 44
6SDXL 18/44 30 40 513 487 469 455 422 378 317 241 151 1919 45
6SDXL 18/45 30 40 525 498 480 465 432 387 324 247 154 1956 46
6SDXL 18/46 30 40 537 509 491 475 442 396 331 252 157 1993 47
6SDXL 18/47 30 40 548 520 501 486 451 404 338 258 161 2031 47,5
6SDXL 18/48 30 40 560 531 512 496 461 413 346 263 164 2068 48
6SDXL 18/49 30 40 572 542 523 506 470 421 353 269 168 2106 50
6SDXL 18/50 37 50 583 553 533 517 480 430 360 274 171 2143 51
6SDXL 18/51 37 50 595 564 544 527 490 439 367 280 174 2181 52
6SDXL 18/52 37 50 607 575 555 537 499 447 374 285 178 2218 53
6SDXL 18/53 37 50 618 586 565 548 509 456 382 291 181 2256 54
6SDXL 18/54 37 50 630 598 576 558 518 464 389 296 185 2293 55
6SDXL 18/55 37 50 642 609 587 568 528 473 396 302 188 2331 56
6SDXL 18/56 37 50 653 620 597 579 538 482 403 307 192 2368 57
6SDXL 18/57 37 50 665 631 608 589 547 490 410 313 195 2406 58
6SDXL 18/58 37 50 677 642 619 599 557 499 418 318 198 2443 59
6SDXL 18/59 37 50 688 653 629 610 566 507 425 324 202 2481 60
6SDXL 18/60 37 50 700 664 640 620 576 516 432 329 205 2518 61
P2 Rated motor power output (...) FK motor rated power output H Total head in m Tolerances according to UNI EN ISO 9906:2012
413
6SDXL 30 Submersible borehole pumps for 6” wells
Characteristic curves
2200
43
42
6SDXL 30
41
40 2000
600 39
38
37 1800
36
35
34
500 33
1600
32
31
30
29
1400
28
400 27 ft
26
25
1200
H 24
m 23
22
21
300 20 1000
19
18
17
16 800
15
14
200
13
12 600
11
10
9
8 400
100 7
6
5
4 200
3
0 0
0 Q m3/h 5 10 15 20 25 30 35 40 45
1,6 100
1,4 80
η (%)
kW/st η (%)
1,2 60
kW/st
1,0 40
2900 rpm
2850 rpm
0,8 20
0 Q m3/h 5 10 15 20 25 30 35 40 72.1164
45
414
6SDXL 30 Submersible borehole pumps for 6” wells
DN
Q nn≈≈2900
29001/min
rpm
3~ P2 Motore
m3/h 0 15 20 25 30 35 40 45 - DN f
CS-R FK
kW HP l/min 0 250 333 416 500 583 666 750 - mm mm mm kg
6SDXL 30/3 4 5,5 46,3 38,9 36 33,3 30,2 26,7 21,7 15,3 - 620 14,7
6SDXL 30/4 5,5 7,5 62,5 52,6 48,8 45,2 41,1 36,5 30 21,4 705 16,8
6SDXL 30/5 7,5 10 78,6 66,2 61,5 56,9 51,8 46,1 38 27,4 790 18,9
6SDXL 30/6 7,5 10 93,1 78,4 72,6 67,1 61 54 44,1 31,2 876 21
6SDXL 30/7 9,2 12,5 110 92,6 86 79,7 72,6 64,6 53,3 38,4 961,5 23,1 f
6SDXL 30/8 11 15 125 106 98,1 90,9 82,7 73,6 60,5 43,5 1047 25,4
6SDXL 30/9 11 15 140 118 109 101 91,8 81,4 66,6 47,3 1132 27,3
6SDXL 30/10 13 (15) 17,5 (20) 158 133 124 115 105 93,5 77,3 56,1 1218 29,4
6SDXL 30/11 15 20 173 146 135 125 114 102 83,8 60,4 1303 31,5
6SDXL 30/12 15 20 188 158 147 136 123 110 90 64,4 1389 33,6
6SDXL 30/13 18,5 25 205 173 161 149 136 121 100 72,4 1474 35,7
6SDXL 30/14 18,5 25 220 185 172 159 145 129 106 76,7 1560 37,8
6SDXL 30/15 22 30 237 200 185 172 157 140 116 84 1645 39,9
6SDXL 30/16 22 30 252 212 197 183 166 148 122 88,3 1730 42
6SDXL 30/17 22 30 267 224 208 193 176 156 129 92,5 1816 44,1
6SDXL 30/18 22 30 281 237 220 203 185 164 135 96,5 145 137 1901 46,1
6SDXL 30/19 26 (30) 35 (40) 302 255 237 220 201 180 149 109 6" 6" 1987 48,2
Ø 135 4", 6"
6SDXL 30/20 26 (30) 35 (40) H 317 267 249 231 210 188 156 114 2072 50,3
Rp
6SDXL 30/21 26 (30) 35 (40) m 332 280 260 241 220 197 163 118 2157 52,4
3”
6SDXL 30/22 30 40 347 293 272 252 230 205 169 123 2243 54,5
6SDXL 30/23 30 40 362 305 283 263 239 213 176 127 2328 56,6
6SDXL 30/24 30 40 377 317 295 273 249 221 182 131 2414 58,7
6SDXL 30/25 37 50 395 333 309 287 261 233 193 140 2499 60,8
6SDXL 30/26 37 50 410 345 321 297 271 242 200 144 2584 62,9
6SDXL 30/27 37 50 425 358 332 308 280 250 206 149 2670 65
Ø 188 8"
6SDXL 30/28 37 50 440 370 344 318 290 258 212 153 2755 67,2 8")
1(
6SDXL 30/29 37 50 454 383 355 329 299 266 219 157 2840 69,2 19 (6")
Ø 7
6SDXL 30/30 37 50 469 395 366 339 308 274 225 161 2926 71,3 14
Ø
6SDXL 30/31 45 60 490 413 384 356 324 289 239 174 3011 75,2
6SDXL 30/32 45 60 505 425 395 366 334 298 246 178 3096 78,3
6SDXL 30/33 45 60 520 438 407 377 343 306 252 182 3182 80,4
6SDXL 30/34 45 60 535 450 418 387 353 314 259 186 3267 82,5
6SDXL 30/35 45 60 549 463 429 398 362 322 265 190 3352 84,6
8")
6SDXL 30/36 45 60 564 475 441 408 371 330 271 194 3438 1( )
87,9 19 4",6"
Ø
6SDXL 30/37 45 60 579 487 452 418 380 338 277 198 3523 90 4(
14
6SDXL 30/38 51 (55) 70 (75) 613 517 482 448 410 369 309 229 3709 92,3 Ø
6SDXL 30/39 51 (55) 70 (75) 628 530 494 459 420 378 316 234 3794 94,5
6SDXL 30/40 51 (55) 70 (75) 644 543 506 471 430 387 323 240 191 196 3879 96,6
6SDXL 30/41 51 (55) 70 (75) 659 557 518 482 440 396 330 245 8" 8" 3965 97,6
6SDXL 30/42 55 75 675 569 530 493 450 404 338 250 4050 98,7
6SDXL 30/43 55 75 690 582 542 504 460 413 345 255 4135 99,8
P2 Rated motor power output (...) FK motor rated power output H Total head in m Tolerances according to UNI EN ISO 9906:2012
415
6SDXL 46 Submersible borehole pumps for 6” wells
Characteristic curves
500
38
37
6SDXL 46
36 1600
35
34 1500
33 1400
32
31
400 1300
30
29
28 1200
H
27
m
26
1100
25
24 ft
300 23 1000
22
21 900
20
19
18 800
17
16 700
200 15
14 600
13
12
500
11
10
9 400
100 8
7 300
6
5
200
4
3
2 100
0 0
0 Q m3/h 10 20 30 40 50 60
1,6 100
1,0 40
0,8 72.1165
20
0 Q m3/h 10 20 30 40 50 60
416
6SDXL 46 Submersible borehole pumps for 6” wells
DN
Q nn≈≈2900
29001/min
rpm
3~ P2 Motore
m3/h 0 25 30 35 40 45 50 55 60 - - DN f
CS-R FK
kW HP l/min 0 416 500 583 666 750 833 916 1000 - - mm mm mm kg
6SDXL 46/2 3 4 26,4 22,6 20,9 19,3 17,8 16,6 15,1 13,4 11,3 - - 96 - 4" 96 - 4" 594 13,5
6SDXL 46/3 4 5,5 39,4 33,8 31,2 28,8 26,6 24,7 22,5 19,9 16,8 705 16,2
6SDXL 46/4 5,5 7,5 52,5 45 41,5 38,3 35,5 32,9 29,9 26,5 22,3 819 18,8
6SDXL 46/5 7,5 10 66,1 56,8 52,3 48,3 44,7 41,5 37,8 33,6 28,4 933 21,4
6SDXL 46/6 9,2 12,5 80,7 70 65,2 60,4 55,5 50,3 46 41,6 35,7 1047 24,0 f
6SDXL 46/7 9,2 12,5 93,1 80,4 74,8 69,3 63,5 57,6 52,7 47,5 40,5 1161 26,6
6SDXL 46/8 11 15 106 91,6 85,1 78,9 72,2 65,5 59,9 54 46 1275 29,2
6SDXL 46/9 13 (15) 17,5 (20) 121 105 98,2 91 83,7 75,9 69,5 62,9 54,1 1389 31,8
6SDXL 46/10 13 (15) 17,5 (20) 134 116 108 100 91,9 83,3 76,2 68,9 59 1503 34,4
6SDXL 46/11 15 20 146 126 118 109 99,9 90,5 82,8 74,7 63,7 1617 37,0
6SDXL 46/12 18,5 25 161 140 130 120 111 101 92 83,3 71,4 1730 39,6
6SDXL 46/13 18,5 25 174 150 140 130 119 108 98,7 89,2 76,3 1844 42,2
6SDXL 46/14 18,5 25 186 161 149 139 127 115 105 95 81 1958 44,8
6SDXL 46/15 22 30 201 174 162 150 138 125 114 103 88,4 145 137 2072 47,4
6SDXL 46/16 22 30 213 184 171 159 146 132 121 109 93,2 6" 6" 2186 50,1
6SDXL 46/17 22 30 225 195 181 168 154 139 127 115 97,8 2300 52,7
6SDXL 46/18 26 (30) 35 (40) 244 212 198 183 169 153 140 127 109 2414 55,3
Ø 135 4", 6"
6SDXL 46/19 26 (30) 35 (40) H 257 223 208 192 177 160 147 133 114 2527 57,9
Rp
6SDXL 46/20 30 40 m 269 234 218 208 185 168 154 139 119 2641 60,5
3”
6SDXL 46/21 30 40 282 244 227 211 193 175 160 145 124 2755 63,1
6SDXL 46/22 30 40 294 255 237 220 202 183 167 151 129 2869 65,7
6SDXL 46/23 30 40 307 265 247 229 209 190 174 157 134 2983 68,3
6SDXL 46/24 37 50 322 280 260 241 222 201 184 166 143 3096 70,9
6SDXL 46/25 37 50 335 290 270 250 230 208 191 172 147 3210 73,5
6SDXL 46/26 37 50 347 301 280 259 238 216 197 178 152 3324 76,1
Ø 188 8"
6SDXL 46/27 37 50 360 311 289 268 246 223 204 184 157 3438 79,3 8")
1(
6SDXL 46/28 37 50 372 321 299 277 254 230 210 190 162 3552 82,0 19 6")
Ø 7(
6SDXL 46/29 45 60 390 339 315 292 268 243 223 201 173 3665 87,4 14
Ø
6SDXL 46/30 45 60 403 349 325 301 276 251 229 207 178 3779 90,0
6SDXL 46/31 45 60 415 360 334 310 284 258 236 213 183 3893 92,6
6SDXL 46/32 45 60 427 370 344 319 292 265 243 219 187 4007 95,2
6SDXL 46/33 45 60 440 380 353 328 300 272 249 225 192 4121 97,8
6SDXL 46/34 51 (55) 70 (75) 469 411 383 355 328 298 272 248 216 4335 101 8")
6SDXL 46/35 1( )
51 (55) 70 (75) 482 422 394 365 337 306 279 255 221 4449 103 19 4",6"
Ø (
6SDXL 46/36 51 (55) 70 (75) 496 434 404 374 346 314 287 261 227 4562 106 14
4
191 196 4676 Ø
6SDXL 46/37 51 (55) 70 (75) 509 445 415 384 355 322 294 268 233 109
6SDXL 46/38 55 75 522 456 425 394 364 330 302 275 238 8" 8" 4790 111
6SDXL 46/39 55 75 535 467 436 403 372 338 309 281 244 4904 114
6SDXL 46/40 55 75 548 479 446 413 381 346 316 288 249 5018 117
P2 Rated motor power output (...) FK motor rated power output H Total head in m Tolerances according to UNI EN ISO 9906:2012
417
6SDXL 65 Submersible borehole pumps for 6” wells
Characteristic curves
31 1400
30 6SDXL 65
400 29 1300
28
27
1200
350 26
25 1100
24
23
1000
300 22
ft
H 21
900
m 20
19
250
18 800
17
16 700
200 15
14
600
13
12
150 500
11
10
9 400
8
100 7
300
6
5
200
4
50
3
2 100
0 0
0 Q m3/h 10 20 30 40 50 60 70 80 90
2,0 100
1,8 η (%) 80
kW/st η (%)
kW/st
1,6 60
2900 rpm
1,4 40
2850 rpm
1,2 72.1166
20
0 Q m3/h 10 20 30 40 50 60 70 80 90
418
6SDXL 65 Submersible borehole pumps for 6” wells
DN
Q ≈ 2900
n ≈n2900 1/minrpm
3~ P2 Motore
m3/h 0 35 40 45 50 55 60 65 70 75 80 DN f
CS-R FK
kW HP l/min 0 583 666 750 833 916 1000 1083 1166 1250 1333 mm mm mm kg
6SDXL 65/2 4 5,5 26,8 21,1 19 17,3 16,5 15,7 14,9 13,9 12,4 10,5 8,2 592 13,6
6SDXL 65/3 5,5 7,5 40,4 31,8 28,8 26,2 24,9 23,7 22,5 21 18,9 16 12,6 705 16,2
6SDXL 65/4 7,5 10 54 42,5 38,4 35 33,2 31,6 30,1 28 25,2 21,4 16,9 819 18,8
6SDXL 65/5 9,2 12,5 68 53,8 48,7 44,3 41,9 40,1 38,2 35,6 32,2 27,5 22 933 21,4
6SDXL 65/6 11 15 81,2 64 57,9 52,7 50 47,7 45,3 42,3 38,1 32,3 25,7 1047 24,0 f
6SDXL 65/7 13 (15) 17,5 (20) 94,9 76,2 70,1 65,2 61,7 58,6 55,7 52,1 46,1 39,7 33,4 1161 26,7
6SDXL 65/8 15 20 108 86 79,1 73,5 69,7 66,1 62,8 58,5 51,6 44,3 37 1275 29,3
6SDXL 65/9 15 20 120 95,5 87,8 81,5 77,4 73,4 69,6 64,6 56,8 48,6 40,2 1389 31,9
6SDXL 65/10 18,5 25 134 108 99 91,9 87,2 82,7 78,5 73,2 64,6 55,5 46,3 1503 34,5
6SDXL 65/11 18,5 25 147 117 108 100 95 90 85,4 79,4 69,8 59,9 49,6 1617 37,1
6SDXL 65/12 22 30 161 129 118 110 104 99,1 94,1 87,6 77,3 66,3 55,3 145 137 1730 39,7
6SDXL 65/13 22 30 174 138 127 118 112 106 101 93,8 82,5 70,8 58,6 6" 6" 1844 42,4
6SDXL 65/14 26 (30) 35 (40) 190 153 141 131 124 118 112 105 93 80,2 67,7 1958 44,9
6SDXL 65/15 26 (30) 35 (40) H 203 163 150 140 132 126 119 111 98,7 85 71,5 2072 47,5
6SDXL 65/16 30 40 m 216 173 159 148 140 133 126 118 104 89,7 75,2 2186 50,2
6SDXL 65/17 30 40 229 183 168 156 148 141 133 124 110 94,3 78,8 2300 52,8
6SDXL 65/18 37 50 243 195 180 167 158 150 143 133 118 101 85,2 2414 55,4
Ø 135 6"
6SDXL 65/19 37 50 256 205 189 175 166 158 150 140 123 106 88,9 2527 58,0
Rp
6SDXL 65/20 37 50 269 215 198 184 174 165 157 146 129 111 92,4 2641 60,7
3”
6SDXL 65/21 37 50 281 225 206 192 182 173 164 152 134 115 95,7 2755 63,3
6SDXL 65/22 45 60 298 239 220 204 194 184 175 163 144 124 104 2869 68,7
6SDXL 65/23 45 60 310 249 229 213 202 191 182 170 150 129 108 2983 71,3
6SDXL 65/24 45 60 323 259 238 221 209 199 189 176 155 133 111 3096 73,9
6SDXL 65/25 45 60 336 268 247 229 217 206 196 182 161 138 115 3210 76,5
6SDXL 65/26 45 60 348 278 255 237 225 213 202 188 166 142 118 3324 79,1
Ø 188 8"
6SDXL 65/27 51 (55) 70 (75) 373 303 279 259 245 233 222 208 186 162 137 3538 82,6 8")
1(
6SDXL 65/28 51 (55) 70 (75) 386 313 288 268 253 241 229 216 193 167 142 3652 85,3 19 6")
191 196 Ø 7(
6SDXL 65/29 51 (55) 70 (75) 399 324 298 277 262 249 237 223 199 172 146 3765 87,9 14
8" 8" Ø
6SDXL 65/30 55 75 413 334 308 286 270 258 245 230 205 177 151 3879 90,5
6SDXL 65/31 55 75 426 345 317 295 279 265 252 237 211 183 155 3993 93,2
8")
1 ( ")
19 6
Ø 4(
14
Ø
P2 Rated motor power output (...) FK motor rated power output H Total head in m Tolerances according to UNI EN ISO 9906:2012
419
8SDX(L) 78 Submersible borehole pumps for 8” wells
400 19 1300
18
1200
17
16
H 1100
m 15 f
300 1000
14
13 900
12
800
11
700
200 10
9 600
8
7
500 Ø 170,5 6"
6 400
100 5
4 300
3 f
200
L
2
100
0 0
0 Q m3/h 20 30 40 50 60 70 80 90 100 110 Ø 188 8"
4,4 100
η (%) 8")
4,0 80 8") 8(
5 ( ") 19 6")
19 6 Ø 2(
3,6 60 Ø 7( 19
18 Ø
kW/st η (%) Ø
kW/st
3,2 40
2,8 20
2,4 72.1167
0
0 Q m3/h 20 30 40 50 60 70 80 90 100 110
Q n ≈n 2900
≈ 2900
rpm1/min Motor
3~ P2
m3 /h 0 30 40 50 60 70 80 90 100 DN f 8SDXL
CS-R FK
kW HP l/min 0 500 666 833 1000 1166 1333 1500 1666 mm mm mm kg
8SDX 78/2 - 8SDXL 78/2 7,5 10 39,9 37,1 34,9 32,6 29,7 27,1 24,3 20,4 16,3 644 31,5
8SDX 78/3 - 8SDXL 78/3 11 15 59,8 55,7 52,3 48,9 44,6 40,7 36,4 30,6 24,4 770 36,5
8SDX 78/4 - 8SDXL 78/4 15 20 79,7 74,3 69,7 65,1 59,4 54,3 48,6 40,9 32,6 896 41,5
8SDX 78/5 - 8SDXL 78/5 18,5 25 99,6 92,9 87,1 81,4 74,3 67,9 60,7 51,1 40,7 1022 46,5
8SDX 78/6 - 8SDXL 78/6 22 30 120 111 105 97,7 89,1 81,4 72,9 61,3 48,9 1148 51
8SDX 78/7 - 8SDXL 78/7 26 (30) 35 (40) 140 130 122 114 104 95 85 71,5 57 145 137 1274 56
8SDX 78/8 - 8SDXL 78/8 30 40 156 146 138 128 117 107 94,5 80 63,3 6" 6" 1400 61
8SDX 78/9 - 8SDXL 78/9 37 50 176 164 155 144 132 120 106 90 71,2 1526 66
8SDX 78/10 - 8SDXL 78/10 37 50 195 183 173 160 147 134 118 100 79,1 1652 71
8SDX 78/11 - 8SDXL 78/11 45 60 215 201 190 176 162 147 130 110 87 1778 76
8SDX 78/12 - 8SDXL 78/12 45 60 248 232 218 203 187 171 154 130 105 Rp 1909 82
8SDX 78/13 - 8SDXL 78/13 51 (55) 70 (75)
H 268 251 237 220 203 185 166 141 114 2035 87
m 5”
8SDX 78/14 - 8SDXL 78/14 51 (55) 70 (75) 289 271 255 237 218 200 179 152 122 2161 92
8SDX 78/15 - 8SDXL 78/15 55 75 310 290 273 254 234 214 192 163 131 2287 97
8SDX 78/16 - 8SDXL 78/16 59 (75) 80 (100) 332 312 293 274 252 232 206 176 143 2413 101,5
8SDX 78/17 - 8SDXL 78/17 66 (75) 90 (100) 353 332 311 292 268 247 219 187 152 2539 106,5
8SDX 78/18 - 8SDXL 78/18 66 (75) 90 (100) 374 351 329 309 284 261 232 198 161 2665 111,5
191 196
8SDX 78/19 - 8SDXL 78/19 75 100 394 371 348 326 299 276 245 209 170 8" 2791 116,5
8"
8SDX 78/20 - 8SDXL 78/20 75 100 415 390 366 343 315 290 258 220 179 2917 121
8SDX 78/21 - 8SDXL 78/21 75 100 436 409 385 361 331 304 271 231 187 3043 126
8SDX 78/22 - 8SDXL 78/22 92 125 457 428 403 378 347 318 284 242 196 3169 131
8SDX 78/23 - 8SDXL 78/23 92 125 478 448 422 395 363 333 297 253 205 3295 136
8SDX 78/24 - 8SDXL 78/24 92 125 499 467 440 412 379 347 310 264 214 3421 141
P2 Rated motor power output (...) FK motor rated power output H Total head in m Tolerances according to UNI EN ISO 9906:2012
420
8SDX(L) 97 Submersible borehole pumps for 8” wells
23 1700 DN
500
22
8SDX 97 ft
1600
21 8SDXL 97
1500
20
19 1400
400 18
1300
17
16 1200
H
m 15 1100
14 f
300 1000
13
12 900
11 800
10
700
200 9
600
8
7 500 Ø 170,5 6"
6
400
5
100
4 300
3 f
200
L
2
100
0 0
0 Q m3/h 20 30 40 50 60 70 80 90 100 110 120 130 Ø 188 8"-10"
5 100
η (%) 8")
4,6 80 8") 8(
5 ( ") 19 6")
19 6 Ø 2(
4,2 60 Ø 7( 19
18 Ø
kW/st kW/st η (%) Ø
3,8 40
3,4 20
3 0
Q m3/h 20
72.1168
0 30 40 50 60 70 80 90 100 110 120 130
Q nn≈≈2900
2900rpm
1/min
Motor
3~ P2
m /h3
0 40 50 60 70 80 90 100 110 120 DN f 8SDXL
CS-R FK
kW HP l/min 0 666 833 1000 1166 1333 1500 1666 1833 2000 mm mm mm kg
8SDX 97/2 - 8SDXL 97/2 9,2 12,5 41,2 38,6 35,2 32,2 29,8 27,8 24,8 21,8 18,6 14,8 644 31,5
8SDX 97/3 - 8SDXL 97/3 13 (15) 17,5 (20) 61,8 57,9 52,8 48,3 44,7 41,7 37,2 32,7 27,9 22,2 770 36,5
8SDX 97/4 - 8SDXL 97/4 18,5 25 82,4 77,2 70,4 64,4 59,6 55,6 49,6 43,6 37,2 29,6 896 41,5
8SDX 97/5 - 8SDXL 97/5 22 30 103 96,5 88 80,5 74,5 69,5 62 54,5 46,5 37 1022 46
8SDX 97/6 - 8SDXL 97/6 26 (30) 35 (40) 125 113 105 96,7 89 82,7 75 66,3 55 44 145 137 1148 51
8SDX 97/7 - 8SDXL 97/7 30 40 146 132 123 113 104 96,4 87,5 77,4 64,2 51,3 6" 6" 1274 56
8SDX 97/8 - 8SDXL 97/8 37 50 167 151 140 129 119 110 100 88,4 73,3 58,7 1400 61
8SDX 97/9 - 8SDXL 97/9 37 50 188 170 158 145 134 124 113 99,5 82,5 66 1526 66
8SDX 97/10 - 8SDXL 97/10 45 60 219 200 185 172 158 147 135 119 102 83,1 1657 72
8SDX 97/11 - 8SDXL 97/11 51 (55) 70 (75) 241 220 204 189 174 162 149 131 112 91,4 1783 77
8SDX 97/12 - 8SDXL 97/12 51 (55) 70 (75) 263 240 222 206 190 176 162 143 122 99,7 Rp 1909 82
8SDX 97/13 - 8SDXL 97/13 55 75 H 285 260 241 223 206 191 176 155 132 108 2035 87
m 5”
8SDX 97/14 - 8SDXL 97/14 59 (75) 80 (100) 309 281 262 242 224 208 191 169 144 120 2161 92
240 222 205 182 191
8SDX 97/15 - 8SDXL 97/15 66 (75) 90 (100) 331 302 279 261 156 129 2287 97
8"
8SDX 97/16 - 8SDXL 97/16 75 100 353 322 298 278 256 237 219 194 166 138 2413 102
8SDX 97/17 - 8SDXL 97/17 75 100 375 342 317 295 272 251 233 206 176 147 2539 106,5
266 246 218 196
8SDX 97/18 - 8SDXL 97/18 92 125 397 362 335 313 288 187 155 2665 111,5
8"
8SDX 97/19 - 8SDXL 97/19 92 125 419 382 354 330 304 281 260 230 197 164 2791 116,5
8SDX 97/20 - 8SDXL 97/20 92 125 440 403 374 348 322 298 274 244 209 173 2917 121
8SDX 97/21 - 8SDXL 97/21 92 125 462 424 393 365 338 313 288 257 219 182 3043 126
8SDX 97/22 - 8SDXL 97/22 110 150 484 444 411 383 354 328 301 269 230 190 3169 131
240
8SDX 97/23 - 8SDXL 97/23 110 150 507 464 430 400 370 343 315 281 240 199 3295 136
10"
P2 Rated motor power output (...) FK motor rated power output H Total head in m Tolerances according to UNI EN ISO 9906:2012
421
422
03/2021
Construction
Submersible borehole pumps for 6” wells (DN 150 mm),
8” (DN 200 mm) and 10” (DN 250 mm), with stages in cast
iron or in bronze, on request.
Impellers: - mixed flow impellers.
Connection: - screwed connection ISO 228 for 6SDS;
- flange with counter-flange for welding for 8SDS
and 10SDS
Applications
For water supply.
For civil and industrial applications.
For fire fighting applications.
For irrigation.
Operating conditions
Liquid temperature up to a 25 °C.
Max. sand quantity into the water: 150 g/m3 (300 g/m 3 high
percentage of solids and sand).
Continuous duty.
423
SDS Submersible borehole pumps for 6”,8” and 10” wells
300
SDS 1000
8SDS 70 10SDS H
200 160 ft
H 500
m 6
6SDS 32 SDS 400
100 42
300
6SDS 58
200
8SDS 100 8SDS 150 10SDS 10SDS 280
50 190
40
30 100
20
50
40
10
30
20
5
10 m3/h 20 30 40 50 100 200 300 400
200 Q l/min 300 400 500 1000 2000 3000 4000 5000 6000
72.1003/2
424
6SDS 32 Submersible borehole pumps for 6” wells
23
300
6SDS 32 1000
22
B-6SDS 32
21 Pumps for specific applications with H
20 high percentage of solids and sand ft CALPEDA
19
H
18 800
m
17
16
15
200
14 f
600
13
12
11
10
9 400
8
100 7
3.93.065/1
6
5
4 200
9 3
3 14 15
0 0
0 m 3/h 10 20 30 40 50
0
Q l/min 200 400 600 800
0 l/s 5 10 72.1039
Q n≈ 2900 rpm
3~ P2
m /h
3
12 18 21 24 27 30 33 36 39 42 DN f 6SDS B-6SDS
kW HP l/min 200 300 350 400 450 500 550 600 650 700 mm kg kg
6SDS 32/3 - B-6SDS 32/3 4 5,5 39 37 35,5 33,5 31,5 30 26,5 24 21 18 686 30,5 35,5
6SDS 32/4 - B-6SDS 32/4 5,5 7,5 52 49 47 45 42 39,5 35,5 32 28 24 788 35,6 41,6
6SDS 32/5 - B-6SDS 32/5 7,5 10 65 61,5 59 56 52,5 49,5 44,5 40 35 30 890 41 49
6SDS 32/6 - B-6SDS 32/6 7,5 10 78 74 71 67 63 59,5 53,5 48 42 36 992 46 55
6SDS 32/7 - B-6SDS 32/7 9,2 12,5 92 86 82,5 78,5 73,5 69 62 56 49 42 1094 52,3 62,3
6SDS 32/8 - B-6SDS 32/8 11 15 105 98,5 94,5 89,5 84 79 71 64 56 48 1196 57 68
6SDS 32/9 - B-6SDS 32/9 13 (15) 17,5 (20) 118 111 106 101 94,5 89 80 72 63 54 1298 62,5 74,5
6SDS 32/10 - B-6SDS 32/10 13 (15) 17,5 (20) 131 123 118 112 105 99 89 80 70 60 1400 68,5 81,5
6SDS 32/11 - B-6SDS 32/11 15 20 144 135 130 123 115 109 98 88 77 66 1502 72,5 86,5
6SDS 32/12 - B-6SDS 32/12 15 20 157 147 141 134 126 119 107 96 84 72 1604 77,5 93,5
6SDS 32/13 - B-6SDS 32/13 18,5 25
H 170 160 153 145 136 129 116
G3
1706 84 101
104 91 78 ISO 228
m
6SDS 32/14 - B-6SDS 32/14 18,5 25 183 172 165 157 147 138 124 112 98 84 1808 89 108
6SDS 32/15 - B-6SDS 32/15 22 30 196 184 177 168 157 148 133 120 105 90 1910 94,2 112
6SDS 32/16 - B-6SDS 32/16 22 30 209 197 189 179 168 158 142 128 112 96 2012 100 119
6SDS 32/17 - B-6SDS 32/17 22 30 223 209 200 190 178 168 151 136 119 102 2114 105 125
6SDS 32/18 - B-6SDS 32/18 26 (30) 35 (40) 236 221 212 201 189 178 160 144 126 108 2216 111 132
6SDS 32/19 - B-6SDS 32/19 26 (30) 35 (40) 246 234 224 213 199 188 169 152 133 114 2318 116 139
6SDS 32/20 - B-6SDS 32/20 26 (30) 35 (40) 262 246 236 224 210 198 178 160 140 120 2420 122 145
6SDS 32/21 - B-6SDS 32/21 26 (30) 35 (40) 275 258 248 235 220 208 187 168 147 126 2522 127 151
6SDS 32/22 - B-6SDS 32/22 30 40 288 270 259 246 231 218 196 176 154 132 2624 132 157
6SDS 32/23 - B-6SDS 32/23 30 40 301 283 271 257 241 228 205 184 161 138 2726 137 164
P2 Rated motor power output (...) FK motor rated power output H Total head in m Tolerances according to UNI EN ISO 9906:2012
425
6SDS 42 Submersible borehole pumps for 6” wells
H 17
H
m 16 ft
200 15
14
600
13 f
12
150 11
10
9 400
8
100
7
6 3.93.065/1
5
200
4
50 9 3
3 14 15
0 0 0
m 3/h 10 20 30 40 50 60
Q l/min
0 200 400 600 800 1000
0 l/s 5 10 15 72.1040
Q n≈ 2900 rpm
3~ P2
m /h 3
18 24 30 33 36 39 42 45 48 51 DN f 6SDS B-6SDS
kW HP l/min 300 400 500 550 600 650 700 750 800 850 mm kg kg
6SDS 42/2 - B-6SDS 42/2 4 5,5 27 25,5 23,5 22,5 21,5 20 18,5 17 15,5 14 584 25,5 29,5
6SDS 42/3 - B-6SDS 42/3 5,5 7,5 40 38 35,5 34 32 30 28 25,5 23 21 686 31,6 36,6
6SDS 42/4 - B-6SDS 42/4 7,5 10 53,5 51 47 45 43 40 37 34 31 27,5 788 36 42
6SDS 42/5 - B-6SDS 42/5 9,2 12,5 67 63,5 59 56,5 53,5 50 46,5 42,5 38,5 34,5 890 40,3 48,3
6SDS 42/6 - B-6SDS 42/6 11 15 80,5 76 71 68 64 60 56 51 46 41,5 992 47 59
6SDS 42/7 - B-6SDS 42/7 13 (15) 17,5 (20) 94 89 82,5 79 75 70 65 59,5 54 48 1094 50,5 65,5
6SDS 42/8 - B-6SDS 42/8 15 20 107 101 94,5 90,5 85,5 80 74,5 68 61,5 55 1196 55,5 66,5
6SDS 42/9 - B-6SDS 42/9 15 20 120 114 106 102 96 90 84 76,5 69 62 1298 62,5 74,5
6SDS 42/10 - B-6SDS 42/10 18,5 25
H 134 127 118 113 107 100 93 85 77 69
G3
1400 69 81
m ISO 228
6SDS 42/11 - B-6SDS 42/11 18,5 25 147 140 130 124 118 110 102 93,5 85 76 1502 74 86
6SDS 42/12 - B-6SDS 42/12 22 30 161 152 141 135 128 120 111 102 92,5 83 1604 79,2 94,2
6SDS 42/13 - B-6SDS 42/13 22 30 174 165 153 147 139 130 121 110 100 90 1706 83,2 99,2
6SDS 42/14 - B-6SDS 42/14 26 (30) 35 (40) 187 178 165 158 150 140 130 119 108 96,5 1808 91,4 106
6SDS 42/15 - B-6SDS 42/15 26 (30) 35 (40) 201 190 177 169 160 150 139 127 115 103 1910 96,4 113
6SDS 42/16 - B-6SDS 42/16 30 40 214 203 189 181 171 160 149 136 123 110 2012 101 119
6SDS 42/17 - B-6SDS 42/17 30 40 228 216 200 192 182 170 158 144 131 117 2114 106 126
6SDS 42/18 - B-6SDS 42/18 30 40 241 228 212 203 192 180 167 153 138 124 2216 111 132
P2 Rated motor power output (...) FK motor rated power output H Total head in m Tolerances according to UNI EN ISO 9906:2012
426
6SDS 58 Submersible borehole pumps for 6” wells
200
6SDS 58
B-6SDS 58
Pumps for specific applications with
high percentage of solids and sand 600
H CALPEDA
m 17
16
H
150 15 ft
14
13 f
12 400
11
100 10
9
8
7
6 200 3.93.065/1
5
50
4
9 3
3 14 15
0 0
0 m 3/h 20 30 40 50 60 70 80 90
Q l/min
0 500 1000 1500
72.1044
0 l/s 5 10 15 20 25
Q n≈ 2900 rpm
3~ P2
m3/h 27 35 40 45 50 55 60 65 70 75 80 DN f 6SDS B-6SDS
kW HP l/min 450 583 666 750 833 916 1000 1083 1166 1250 1333 mm kg kg
6SDS 58/2 - B-6SDS 58/2 4 5,5 21 20 19 18 17 16,5 15,5 14 12,5 11 9 584 26,5 29,5
6SDS 58/3 - B-6SDS 58/3 5,5 7,5 32 30 28,5 27 26 24,5 23 21 18,5 16 13,5 686 31,6 36,6
6SDS 58/4 - B-6SDS 58/4 7,5 10 42,5 39,5 38 36 34,5 33 31 28 25 21,5 18 788 37 43
6SDS 58/5 - B-6SDS 58/5 9,2 12,5 53 49,5 47,5 45 43 41 38,5 35 31 27 22,5 890 43,3 50,3
6SDS 58/6 - B-6SDS 58/6 11 15 63,5 59,5 57 54 51,5 49 46 42 37 32,5 27 992 48 57
6SDS 58/7 - B-6SDS 58/7 13 (15) 17,5 (20) 74 69,5 66,5 63 60 57,5 54 49 43,5 38 31,5 1094 53,5 63,5
6SDS 58/8 - B-6SDS 58/8 15 20 85 79 76 72 69 66 62 56 49,5 43 36 1196 59,5 70,5
6SDS 58/9 - B-6SDS 58/9 18,5 25 H 95,5 89 85,5 81 77,5 74 69,5 63 56 49 40,5 G4 1298 65 77
6SDS 58/10 - B-6SDS 58/10 18,5 25 m 106 99 95 90 86 82 77 70 62 54 45 ISO 228 1400 71 84
6SDS 58/11 - B-6SDS 58/11 22 30 117 109 104 99 94,5 90 85 77 68 59,5 49,5 1502 76,2 90,2
6SDS 58/12 - B-6SDS 58/12 22 30 127 119 114 108 103 100 94,5 86,5 76,5 66,5 55,5 1604 82,2 97,2
6SDS 58/13 - B-6SDS 58/13 26 (30) 35 (40) 138 129 123 117 112 107 100 91 80,5 70 58,5 1706 87,4 104
6SDS 58/14 - B-6SDS 58/14 26 (30) 35 (40) 148 139 133 126 120 115 108 98 87 75,5 63 1808 93,4 111
6SDS 58/15 - B-6SDS 58/15 30 40 159 148 142 135 129 123 115 105 93 81 67,5 1910 99,4 118
6SDS 58/16 - B-6SDS 58/16 30 40 170 158 152 144 138 131 123 112 99 86,5 72 2012 104 124
6SDS 58/17 - B-6SDS 58/17 30 40 180 168 162 153 146 139 131 119 105 92 76,5 2114 110 131
P2 Rated motor power output (...) FK motor rated power output H Total head in m Tolerances according to UNI EN ISO 9906:2012
427
8SDS 70 Submersible borehole pumps for 8” wells
0 50 100 Imp. g.p.m. 200 250 300 350 Counter-flange for welding.
500
20
8SDS 70 1600
19
B-8SDS 70 190 DN
83
18 1400
109
400
17 H
16 ft CALPEDA
40
H 15 1200
m
14
Ø 15
13 168
300 1000
12 f
11
10 800
9
200
8
600
.
7
6
3.93.066.N
5 400
100 4
9
3 2 19
19
200
2
1
0 0
0 m 3/h 20 40 60 80 100
0
Q l/min 500 1000 1500
0 l/s 5 10 15 20 25 72.972
Q n≈ 2900 rpm
3~ P2 Motor
m /h 3
15 20 30 40 50 60 70 80 90 DN f 8SDS B-8SDS
CS-R FK
kW HP l/min 250 333 500 666 833 1000 1166 1333 1500 mm mm mm kg kg
428
8SDS 100 Submersible borehole pumps for 8” wells
.
CALPEDA
1000
300 14
40
13
Ø 15
12 168
800
11 f
10
200
9
600
8
.
7
6
400 3.93.066.1.N
5
100
4
9
2 19
19
3
200
2
0 0
0 m3/h 40 60 80 100 120 140
0
Q l/min 500 1000 1500 2000
0 l/s 10 20 30 72.970
Q n≈ 2900 rpm
3~ P2 Motor
m /h3
30 40 50 60 70 80 90 100 110 125 DN f 8SDS B-8SDS
CS-R FK
kW HP l/min 500 666 833 1000 1166 1333 1500 1666 1833 2083 mm mm mm kg kg
8SDS 100/1 - B-8SDS 100/1 5,5 7,5 21,5 21 20,5 20 19 18 17 15,5 14 10,5 602 38 43
8SDS 100/2 - B-8SDS 100/2 11 15 43 42 41 40 38 36 34 31 28 21 734 49 55
8SDS 100/3 - B-8SDS 100/3 18,5 25 64,5 63 61,5 60 57 54 51 46,5 42 31,5 866 59 67
8SDS 100/4 - B-8SDS 100/4 22 30 86 84 82 80 76 72 68 62 56 42 145 137 998 70 79
8SDS 100/5 - B-8SDS 100/5 30 40 107 105 102 100 95 90 85 77,5 70 52,5 6” 6” 1130 81 91
8SDS 100/6 - B-8SDS 100/6 37 50 129 126 123 120 114 108 102 93 84 63 1262 92 103
8SDS 100/7 - B-8SDS 100/7 45 60 150 147 143 140 133 126 119 108 98 73,5 1394 102 115
8SDS 100/8 - B-8SDS 100/8 45 60 172 168 164 160 152 144 136 124 112 84 1526 113 128
8SDS 100/9 - B-8SDS 100/9 51 (55) 70 (75)
H 193 189 184 180 171 162 153 139 126 94,5
125
1658 124 140
m
8SDS 100/10 - B-8SDS 100/10 55 75 215 210 205 200 190 180 170 155 140 105 1790 135 152
8SDS 100/11 - B-8SDS 100/11 66 (75) 90 (100) 236 231 225 220 209 198 187 170 154 115 1922 145 164
8SDS 100/12 - B-8SDS 100/12 66 (75) 90 (100) 258 252 246 240 228 216 204 186 168 126 191 196 2054 156 176
8SDS 100/13 - B-8SDS 100/13 75 100 279 273 266 260 247 234 221 201 182 136 8” 8” 2186 167 188
8SDS 100/14 - B-8SDS 100/14 92 125 301 294 287 280 266 252 238 217 196 147 2318 177 200
8SDS 100/15 - B-8SDS 100/15 92 125 322 315 307 300 285 270 255 232 210 157 2450 188 212
8SDS 100/16 - B-8SDS 100/16 92 125 344 336 328 320 304 288 272 248 224 168 2582 199 224
P2 Rated motor power output (...) FK motor rated power output H Total head in m Tolerances according to UNI EN ISO 9906:2012
429
8SDS 150 Submersible borehole pumps for 8” wells
0 100 200 Imp. g.p.m. 400 500 600 700 Counter-flange for welding.
340
.
15 ft CALPEDA
40
m 800
14
13 Ø 15
168
12
200 f
11
600
10
.
7 400
6
100 3.93.066.1.N
4 9
2 19
200 19
3
0 0
0 m3/h 40 80 120 160 200
0 Q l/min 1000 2000 3000
0 l/s 10 20 30 40 50 72.971
Q n≈ 2900 rpm
3~ P2 Motor
m3/h 60 70 80 90 100 110 125 140 150 160 180 DN f 8SDS B-8SDS
CS-R FK
kW HP l/min 1000 1166 1333 1500 1666 1833 2083 2333 2500 2666 3000 mm mm mm kg kg
8SDS 150/1 - B-8SDS 150/1 7,5 10 18 17,5 17 16,5 16 15,5 14,5 13 11,5 10,5 5,5 602 38 43
8SDS 150/2 - B-8SDS 150/2 15 20 36 35 34 33 32 31 29 26 23 21 11 734 49 55,5
8SDS 150/3 - B-8SDS 150/3 22 30 54 52,5 51 49,5 48 46,5 43,5 39 34,5 31,5 16,5 145 137 866 60 68
8SDS 150/4 - B-8SDS 150/4 30 40 72 70 68 66 64 62 58 52 46 42 22 6” 6” 998 71,5 80,5
8SDS 150/5 - B-8SDS 150/5 37 50 90 87,5 85 82,5 80 77,5 72,5 65 57,5 52,5 27,5 1130 82,5 93
8SDS 150/6 - B-8SDS 150/6 45 60 108 105 102 99 96 93 87 78 69 63 33 1262 93,5 106
8SDS 150/7 - B-8SDS 150/7 51 (55) 70 (75) 126 122 119 115 112 108 101 91 80,5 73,5 38,5 1394 105 118
H
8SDS 150/8 - B-8SDS 150/8 59 (75) 80 (100) 144 140 136 132 128 124 116 104 92 84 44 125 1526 116 131
m
8SDS 150/9 - B-8SDS 150/9 66 (75) 90 (100) 162 157 153 148 144 139 130 117 103 94,5 49,5 191 1658 127 143
8SDS 150/10 - B-8SDS 150/10 75 100 180 175 170 165 160 155 145 130 115 105 55 8” 1790 138 156
196
8SDS 150/11 - B-8SDS 150/11 92 125 198 192 187 181 176 170 159 143 126 115 60,5 1922 149 168
8”
8SDS 150/12 - B-8SDS 150/12 92 125 216 210 204 198 192 186 174 156 138 126 66 2054 160 181
8SDS 150/13 - B-8SDS 150/13 110 150 234 227 221 214 208 201 188 169 149 136 71,5 2186 171 194
240
8SDS 150/14 - B-8SDS 150/14 110 150 252 245 238 231 224 217 203 182 161 147 77 2318 182 206
10”
8SDS 150/15 - B-8SDS 150/15 110 150 270 262 255 247 240 232 217 195 172 157 82,5 2450 193 219
P2 Rated motor power output (...) FK motor rated power output H Total head in m Tolerances according to UNI EN ISO 9906:2012
430
10SDS 160 Submersible borehole pumps for 10” wells
0 100 200 Imp. g.p.m. 400 500 600 700 Counter-flange for welding.
400
9
10SDS 160 1200
H B-10SDS 160 235 DN
m 107
ft
179
8
1000
300 CALPEDA
Ø 15
6 800 210
f
200 5
600
3 400 3.93.067.N
100
2
3
3 26
25
200
1
0 0
0 m3/h 40 80 120 160 200
0
Q l/min 1000 2000 3000
0 l/s 10 20 30 40 50 72.334.1
Q n≈ 2900 rpm
3~ P2 Motor
m /h
3
80 90 100 110 125 140 150 160 170 180 190 DN f 10SDS B-10SDS
CS-R FK
kW HP l/min 1333 1500 1666 1833 2083 2333 2500 2666 2833 3000 3166 mm mm mm kg kg
10SDS 160/1 - B-10SDS 160/1 18,5 25 39,5 38 37,5 36 34,5 32,5 31 29 26,5 22 20 145 137 865 77 87
10SDS 160/2 - B-10SDS 160/2 37 50 78,5 76,5 74,5 72,5 69 65 62 58,5 53,5 44 40 6” 6” 1035 103 114
10SDS 160/3 - B-10SDS 160/3 55 75 118 114 112 108 104 98 92,5 87,5 80 66,5 60 1205 126 141
191
10SDS 160/4 - B-10SDS 160/4 75 100 157 153 149 145 138 130 123 117 107 88,5 80 1375 150 169
H 8” 196
10SDS 160/5 - B-10SDS 160/5 92 125 196 191 186 181 173 163 154 146 134 111 100 175 1545 173 195
m 8”
10SDS 160/6 - B-10SDS 160/6 110 150 236 229 224 217 207 195 185 175 160 133 120 1715 197 222
10SDS 160/7 - B-10SDS 160/7 130 175 275 267 261 253 242 228 216 204 187 155 140 240 1885 220 249
10SDS 160/8 - B-10SDS 160/8 150 200 314 305 298 289 276 260 246 233 213 177 160 10” 2055 244 276
10SDS 160/9 - B-10SDS 160/9 185 250 356 342 338 324 311 293 279 261 239 198 180 - 2225 268 303
P2 Rated motor power output (...) FK motor rated power output H Total head in m Tolerances according to UNI EN ISO 9906:2012
431
10SDS 190 Submersible borehole pumps for 10” wells
H 10SDS 190 H
m 7 B-10SDS 190 ft 235 DN
107
250
800 179
6
CALPEDA
200
5 Ø 15
600 210
f
4
150
400
3
100
3.93.067.N
200 3
3 26
50 25
1
0 0
0 m3/h 50 100 150 200 250 300
0
Q l/min 1000 2000 3000 4000 5000
0 l/s 20 40 60 72.336.1N 80
Q n≈ 2900 rpm
3~ P2 Motor
m /h 3
100 120 140 160 180 200 220 230 240 250 DN f 10SDS B-10SDS
CS-R FK
kW HP l/min 1666 2000 2333 2666 3000 3333 3666 3833 4000 4166 mm mm mm kg kg
P2 Rated motor power output (...) FK motor rated power output H Total head in m Tolerances according to UNI EN ISO 9906:2012
432
10SDS 280 Submersible borehole pumps for 10” wells
0 200 400 Imp. g.p.m. 800 1000 1200 Counter-flange for welding.
200
150
H CALPEDA
5 ft
Ø 15
H 210
m 4 400
f
100
2 200 3.93.067.N
50
3
3 26
25
1
0 0
0 m3/h 100 150 200 250 300 350 400
0
Q l/min 2000 3000 4000 5000 6000
Q n≈ 2900 rpm
3~ P2 Motor
m3/h 150 180 200 220 240 260 280 300 315 350 DN f 10SDS B-10SDS
CS-R FK
kW HP l/min 2500 3000 3333 3666 4000 4333 4666 5000 5250 5833 mm mm mm kg kg
10SDS 280/1 - B-10SDS 280/1 26 (30) 35 (40) 29 28 27 26 25 24 23 21 20 16 145-6” 137-6” 865 78 88
10SDS 280/2 - B-10SDS 280/2 55 75 59 55 53 51 50 48 46 42 40 31 191 1035 103 116
10SDS 280/3 - B-10SDS 280/3 75 100 H 88 83 80 77 75 71 69 64 60 47 8” 1205 127 143
175 196
10SDS 280/4 - B-10SDS 280/4 110 150 m 118 111 106 103 100 95 92 85 80 63 1375 151 170
240 8”
10SDS 280/5 - B-10SDS 280/5 130 175 147 139 133 129 125 119 115 106 100 79 1545 175 198
10”
10SDS 280/6 - B-10SDS 280/6 150 200 176 167 160 155 150 143 138 127 120 95 1715 199 226
P2 Rated motor power output (...) FK motor rated power output H Total head in m Tolerances according to UNI EN ISO 9906:2012
433
SD, SDS Submersible pumps
Installation examples
12/13 16
4 4 4
11
O O O
I I I
10 14 15
6 7 8 9 6 7 8 9 6 7 8
3 3 3
2 2 2
Hs
Hs
Hs
Hd
Hd
Hd
5 5 5
1 1 1
P
1 Submersible pump
2 Pump support system
3 Electric control board
4 Circuit breaker
5 Minimum level probes
6 Pressure gauge
7 Check valve
8 Throttle gate valve
9 Pressure switch
10 Pressure tank
11 Probes for air entry control
12 Electric valve
13 Compressor
14 Membrane tank
15 Storage tank
16 Start-stop probes
Hs Static level
Hd Dynamic level
P Tubewell depth
434
03/2021
The Calpeda 4”, 6”, 8” and 10" submersible motors are built using
advanced technology and components of superior quality that they
ensure good mechanical strength and excellent electrical reliability.
The good performances are guaranteed thanks to strict tests of all the
different components during the various production phases.
Operation data
2-pole induction motor, 50 Hz (n ≈ 2900 rpm).
Sized for connection to the pumps according to NEMA Standards (10”
excluded).
Standard voltages:
- single-phase 230 V - up to 2,2 kW for 4” motors.
- three-phase 230 V; (5,5 kW excluded) 400 V for 4” motors.
- three-phase 400 V; 400/690 V for 6-8-10” motors.
Voltage tolerance : ± 10% (+6% / -10% for 4”).
In order to limit both current and torque at each starting, for rated
motor powers equal to or higher than 7.5kW, one of the following types
of starting is necessary: star/delta, soft starter, stator impedance or
autotransformer.
Insulation class:
- class F for 4” motors,
- class E for 6” motors, PVC for I-6” (I-6” 45 kW PE2+PA).
- PVC for 8”
- PVC for 10” (10” 170kW and 190 kW PE2+PA )
Protection IP 68.
Installation below water level: 100 m for 4”, 150 m for 6”, 500 m for
8,10”
Motor suitable operation with frequency converter (with suitable filter
dv/dt for 6.8.10”) (4” single-phase excluded).
4" 1 ~ 4" 3 ~ 6" 3 ~ 8" 3 ~ 10" 3 ~ Horizontal installation (6" 37-45kW, 8" 92kW, 10" 170-190 kW exclu-
ded)
CS-R CS-R CS-R I-CS-R CS-R I-CS-R CS-R I-CS-R
kW
316 316 316 Operating conditions
0,37 Motor Max. Cooling Max.
0,55 Liquid minimum starts
0,75 P2 temperature flow velocity per hou
1,1
4CS-R all types 35 °C 0,08 m/s 20
1,5
2,2
6CS-R 4÷11 kW 30 °C 0,1 m/s 15
3 13÷15 kW 30 °C 0,2 m/s 15
4 18,5 kW 25 °C 0,2 m/s 15
5,5 22÷30 kW 25 °C 0,2 m/s 13
7,5 37 kW 40 °C 0,1 m/s 13
9,2
45 kW 40 °C 0,3 m/s 6
11
13
I-6CS-R 4÷37 kW 30 °C 0,15 m/s 20
15 45 kW 45 °C 0,15 m/s 20
18,5 8CS-R all types 30 °C 0,15 m/s 10
22 10CS-R 75÷150 kW 30 °C 0,15 m/s 10
26
170÷190 kW 50 °C 0,15 m/s 10
30
37
Continuous duty.
45
51
59
Special features on request
66
75
- Other voltage.
92 - Frequency 60 Hz.
110 - Higher liquid temperature.
132 - Bronze, AISI 904 and Super Duplex version for 6.8.10”.
150
- PT100 temperature sensor
170
- PE2 / PA winding insulation
190
- Cooling jackets
4.93.325
435
CS, CS-R Submersible motors
Materiales
Components 4” Cable
External frame Cr-Ni steel AISI 304 Motor 230V - 50Hz - 1~ Section Length
4CS-R 0,37 ÷ 2,2 kW 3x2 + 1G2 mm2 2 m
Motor flange Cast iron GJL 200 EN 1561 nickel-plated
Shaft end Cr-Ni-Mo steel AISI 316 Motor 400V - 50Hz - 3 ~ Section Length
Thrust bearing Oil wetted 4CS-R 0,37 ÷ 1,5 kW 3x2 + 1G2 mm 2
2 m
4CS-R 2,2 ÷ 5,5 kW 3x2 + 1G2 mm2 3 m
Components 6”, 8”, 10” standard 6”, 8”, 10” AISI 316
6CS-R 4 ÷ 11 kW 3 x (1x2,5) mm2 3,5 m
External frame Cr-Ni steel AISI 304 Cr-Ni-Mo steel AISI 316 6CS-R 13 ÷ 22 kW 3 x (1x4) mm2 3,5 m
6CS-R 26 - 30 kW 3 x (1x6) mm2 3,5 m
Motor flange Cast iron GJL 200 EN 1561 Cr-Ni-Mo steel AISI 316 6CS-R 37 - 45 kW 3 x (1x10) mm2 3,5 m
(Cast iron G 25 EN 1561 for 8,10”)
I-6CS-R 4 ÷ 15 kW 3 x (1x4) mm2 3,5 m
Shaft end Cr-Ni steel AISI 431 Duplex 1.4462 I-6CS-R 18,5 ÷ 26 kW 3 x (1x6) mm2 3,5 m
(Steel AISI 420 for 8”) I-6CS-R 30 kW 3 x (1x10) mm2 3,5 m
I-6CS-R 37 ÷ 45 kW 3 x (1x10) mm2 4,5 m
Thrust bearing Oscillating pads Oscillating pads
8CS-R 30 kW 3 x (1x10) mm2 3,5 m
Bushings Resin/ Graphite compound Resin/ Graphite compound 8CS-R 37 ÷ 59 kW 3 x (1x16) mm2 3.5 m
(Graphite for 6”) 8CS-R 66 ÷ 75 kW 3 x (1x25) mm2 3.5 m
8CS-R 92 kW 3 x (1x25) mm2 4.5 m
10CS 75 ÷ 92 kW 3x(1x25) mm2 4.5 m
10CS 110 kW 3x(1x35) mm2 4.5 m
10CS 132 kW 3x(1x50) mm2 4.5 m
10CS 150 ÷ 170 kW 3x(1x70) mm2 4.5 m
10CS 190 kW 3x(1x95) mm2 4.5 m
Cooling jacket
(fig. B)
When the submersible motor is installed :
- below the well inlet points (picture A);
- in tanks, lakes, basins, etc… (pictures B and C)
an external jacket must be installed to create a cooling
flow around the motor. Only in this way a safe operation
can be assured avoiding any overheating which can dam-
age the motor.
4.93.324/2
CALPEDA
(fig. A)
4.93.324/2
(fig. C)
CALPEDA
CALPEDA
4.93.324/3
436
CS-R Submersible motors
ø76 ±0,1 25
4"CS-R - 1 ~ 4" NEMA
h8
Type PN M
cos ϕ η% thrust
ø87,3
230 V IA CA 450 Vc
kW HP A 4/4 3/4 2/4 4/4 3/4 2/4 R.P.M. IN CN µF N mm kg
4CS-R 0,37M 0,37 0,5 3.2 0.96 0.93 0.85 53 46 29 3.8 0.78 16 327 7,6 M8x1
4CS-R 0,55M 0,55 0,75 4.0 0.99 0.97 0.89 62 54 35 4.6 0.80 25 362 9,4 ø95
4CS-R 0,75M 0,75 1 5.6 0.96 61 362 9,4 +0,1
+0,30
38 +0,05
0.91 0.80 55 36 3.6 0.66 30 ø15,5 0
2850 1500
4CS-R 1,1M 1,1 1,5 8.0 0.93 0.86 0.71 66 59 38 4.2 0.65 40 402 10,7
4CS-R 1,5M 1,5 2 10.8 0.94 0.89 0.75 64 59 39 3.5 0.75 60 447 12,4
4CS-R 2,2M 2,2 3 14.7 0.96 0.93 0.80 67 64 44 4.2 0.51 70 517 15,7
3
4"CS-R - 3 ~
PN IN Power factor Efficiency Direct start Axial thrust Weight
Type M
400 V cos ϕ η%
IA CA
kW HP A 4/4 3/4 2/4 4/4 3/4 2/4 R.P.M. IN CN N mm kg M
4CS-R 0,37T 0,37 0,5 1.2 0.73 0.64 0.47 63 58 44 5.6 4.2 327 7,7
4CS-R 0,55T 0,55 0,75 1.5 0.80 0.71 0.53 68 66 52 6.1 4.1 327 7,7
4CS-R 0,75T 0,75 1 2.2 0.77 0.69 0.50 65 63 49 4.2 3 347 8,7
1500
4CS-R 1,1T 1,1 1,5 2.8 0.80 0.71 0.49 72 73 62 4.5 3 362 9,5
4CS-R 1,5T 1,5 2 3.7 0.79 0.70 0.47 76 75 65 2850 5.0 3.1 402 10,8
4CS-R 2,2T 2,2 3 5.5 0.81 0.71 0.47 72 73 62 4.9 2.2 402 11,7
4CS-R 3T 3 4 7,4 0,81 0,72 0,56 73,5 73,5 69 5,7 2,16 481 14,9
Ø 96
4CS-R 4T 4 5,5 9,4 0,82 0,74 0,60 74,5 75 71 6,3 2,19 4500 546 18,2
4CS-R 5,5T 5,5 7,5 13 0,81 0,72 0,57 76 76 71 7,8 3,44 646 23
ø25,2
23
6" NEMA
M12
6"CS-R
73
PN IN Power factor Efficiency Direct start Axial thrust Weight
Type M
400 V cos ϕ η% IA CA
Standard kW HP A 4/4 3/4 4/4 3/4 R.P.M. IN CN N mm kg
ø143
6CS-R 4 4 5,5 11 0,80 0,70 70 68 2825 3 1,5 30000 530 30,5
6CS-R 5,5 5,5 7,5 14,5 0,81 0,72 72 72 2815 3,2 1,5 30000 550 33
6CS-R 7,5 7,5 10 18,5 0,80 0,72 76 76 2830 4,1 2 30000 595 38
6CS-R 9,2 9,2 12,5 22 0,80 0,71 78 78 2840 4 1,7 30000 640 41,7 M
6CS-R 11 11 15 26 0,83 0,76 78 79 2835 5,2 2,5 30000 670 44,4
6CS-R 13 13 17,5 31 0,80 0,69 79 78 2840 5 2,6 30000 700 47,7
6CS-R 15 15 20 35 0,80 0,72 81 81 2855 5 1,95 30000 715 52
6CS-R 18,5 18,5 25 42 0,82 0,74 81 82 2840 5,4 2,5 30000 750 56
6CS-R 22 22 30 49,5 0,83 0,76 81 83 2820 4,5 1,7 30000 790 59,8 ø111,2
h8
6CS-R 26 26 35 57,5 0,82 0,74 83 84 2850 5,3 2 30000 875 70 ø76,17
6CS-R 30 30 40 64,6 0,80 0,74 85 87 2845 5,3 2 30000 1025 85,7
6CS-R 37 37 50 82,5 0,80 0,72 86 87 2870 6 2,4 30000 1227 111
6CS-R 45 45 60 98,9 0,80 0,73 85 85 2860 5,1 2 30000 1287 119
56
,5
50
437
CS-R Submersible motors
I-6CS-R 15 15 20 33 0,83 0,77 0,68 81,6 82,8 81,0 2836 4 1,95 25000 827 69
145
I-6CS-R 18,5 18,5 25 40 0,83 0,78 0,69 81,9 82,6 80,3 2853 4 2,5 35000 897 74
I-6CS-R 22 22 30 47 0,82 0,75 0,64 83,5 84 82,1 2868 4 1,7 35000 967 81
I-6CS-R 26 26 35 54 0,82 0,77 0,66 84,5 86,1 85,2 2864 4 2 35000 1027 90
I-6CS-R 30 30 40 62 0,82 0,77 0,66 85 85,7 84,9 2860 4 2 45000 1167 103
ø 112
I-6CS-R 37 37 50 79 0,81 0,75 0,63 83,5 84,6 84,1 2856 4 2,4 45000 1297 117
I-6CS-R 45 45 60 98 0,83 0,76 0,63 80,5 83,4 83,8 2827 4 2 45000 1327 119
ø192
8" NEMA
ø127
ø74
8"CS-R, I-8"CS-R
PN IN Power factor Efficiency Direct start Axial Weight
Type cos ϕ η% thrust M
400 V IA CA
Standard AISI 316 kW HP A 4/4 3/4 2/4 4/4 3/4 2/4 R.P.M. IN CN N mm kg
8CS-R 30 I-8CS-R 30 30 40 61 0,85 0,82 0,75 83,9 84,9 82,3 2886 4,5 1,8 50000 1049 137
8CS-R 37 I-8CS-R 37 37 50 76 0,84 0,8 0,71 84,8 84,7 82,7 2890 4,5 1,8 50000 1119 157
8CS-R 45 I-8CS-R 45 45 60 91 0,84 0,79 0,71 86 86 83,4 2900 4,5 1,9 50000 1229 169
8CS-R 51 I-8CS-R 51 51 70 103 0,85 0,81 0,73 84,9 86,5 85,1 2879 4,5 1,9 60000 1229 170
M
8CS-R 59 I-8CS-R 59 59 80 116 0,83 0,79 0,69 87,5 88,6 87,4 2898 4,5 2 60000 1349 194 Ø192
8CS-R 66 I-8CS-R 66 66 90 129 0,84 0,81 0,72 87,1 88 87 2883 4,5 2 70000 1419 210
8CS-R 75 I-8CS-R 75 75 100 146 0,85 0,81 0,73 86,9 87,7 86,5 2890 4,5 2 70000 1609 241
8CS-R 92 I-8CS-R 92 92 125 181 0,83 0,77 0,66 88,5 88,4 87,9 2900 4,5 2,1 70000 1679 251
ø152,4
ø 17,5
ø127
Type F ø 42,86 80 5
10"CS-R, I-10"CS-R
101,6
IA CA
45°
PN Rated power output IN Rated current IN Starting current / Nominal current CN Starting torque/Nominal torque
ø22
47,6
438
CS-R Submersible motors
80
70
60
[°C]
Temperatura (°C)
Termperature
50
40
30
20
10 100 1000 10000 100000
PITTING
CREVICE Salinità(ppm)
Salinity [ppm]
439
CS-R Submersible motors
230 Volt - 50 Hz - 1 ~
IN 1 four-wires cable 4 x ....mm2
A 1,5 2,5 4 6 10
cables max m
2 142 235
4 71 118 189
6 47 78 126 189
8 35 59 94 142 231
10 28 47 76 113 185
12 24 39 63 95 154
14 20 34 54 81 132
16 18 29 47 71 115
18 26 42 63 103
20 24 38 57 92
Voltage drop 3%.
25 30 45 74
Maximum ambient temperature + 30 °C.
30 25 38 62
Direct-starting
A 1,5 2,5 4 6 10 16 25 35 50 70 95 120 150 A 1,5 2,5 4 6 10 16 25 35 50 70 95 120 150 185 240
cables max m cables max m
2 164 272 2 285 473
4 82 136 218 4 143 236 379
6 55 91 145 218 6 95 158 253
8 41 68 109 164 267 8 71 118 190 285
10 33 54 87 131 213 10 57 95 152 228
12 27 45 73 109 178 12 48 79 126 190 309
14 23 39 62 94 152 239 14 41 68 108 163 265
16 20 34 55 82 133 209 16 36 59 95 142 232
18 30 48 73 118 186 18 53 84 127 206 323
20 27 44 65 107 167 257 20 47 76 114 185 290
25 35 52 85 134 206 25 61 91 148 232 358
30 29 44 71 111 171 233 30 51 76 124 194 298
35 37 61 95 147 200 35 65 106 166 256 347
40 33 53 83 129 175 227 40 57 93 145 224 304
45 47 74 114 155 202 45 82 129 199 270
50 43 67 103 140 181 249 50 74 116 179 243 316
60 56 86 116 151 207 60 97 149 203 263
70 48 73 100 130 178 230 70 83 128 174 225 309
80 64 87 113 155 201 241 80 112 152 197 270
90 57 78 101 138 179 214 90 99 135 175 240 311
100 51 70 91 124 161 193 224 100 89 122 158 216 280
110 64 82 113 146 175 203 110 110 143 197 255 305
120 58 76 104 134 161 186 120 101 132 180 233 279
130 70 96 124 148 172 130 121 166 216 258 299
140 65 89 115 138 160 140 113 155 200 239 278
150 60 83 107 128 149 150 105 144 187 223 259 302
160 57 78 101 120 140 160 99 135 175 209 243 283
170 53 73 95 113 132 170 93 127 165 197 229 267
180 50 69 89 107 124 180 88 120 156 186 216 252 297
190 48 65 85 101 118 190 83 114 147 176 205 239 281
200 45 62 81 96 112 200 79 108 140 168 195 227 267
220 57 73 88 102 220 98 127 152 177 206 243
240 52 67 80 93 240 90 117 140 162 189 223
260 62 74 86 260 108 129 150 174 206
280 58 69 80 280 100 120 139 162 191
300 54 64 75 300 93 112 130 151 178
440
CS-R Submersible motors
Star-delta starting
A A
1,5 2,5 4 6 10 16 25 35 50 70 95 120 150 1,5 2,5 4 6 10 16 25 35 50 70 95 120 150
cables max m cables max m
- Against short-circuits and overloads to the electric pumps system we advise to follow the usually applied normative.
- To avoid a possible dry working of the electric pump in is better to install a level control.
- In order to avoid overheatings, tension grops above 3%, we advise to use suitable starting motors systems.
- All the cable wave to respect the usually applied normative and to present excellent insullation characteristics.
The tables show the maximum length of the cable depending on the current absorbed by the motor and the cross section area of the cable, at diffe-
rent voltages. The maximum voltage drop equal to 3%, cable temperature of 80°C, water installation similar to air installation at a temperature of
30°C.
441
CS-R Submersible motors
For dimensioning the phase cross section area for the submersible motor need the following information:
The choice of the minimum cross section area of the phase conductor is determined by the rated motor current and the values reported in Table 1.
Table 1
* Up to 35 mm sections four-wire cable are used, from 50 mm single core cables are recommended as well.Tab.1
2 2
The maximum current of the cables listed in Table 1 are for ambient temperature of 30 ° C.
When the temperature is different, the maximum current of the cables should be corrected by a factor given in Table 2.
The cross section area of the phase conductor is choosen by checking the voltage drop along the line , through the following equation:
In case of star / delta starting the rated current of the motor should be divided by 1.73.
442
CS-R Submersible motors
PFC-M Control panel for 1 submersible pump with single-phase motor, PF control
Type Setting Capacitor Motor 50/60Hz Dimensions Construction
220V-240V - 1~ HxBxP Control panel for controlling one submersible
A 450Vc kW mm pump with single-phase motor.
PFC-M 18-16 1 - 18 16 μF 0,37 220x210x110 Electronic control of the operation and dry-
running protection through the power factor (PF)
PFC-M 18-20 1 - 18 20 μF 0,55 220x210x110 control.
PFC-M 18-25 1 - 18 25 μF 0,55 220x210x110 The installation of level probes into the well is
PFC-M 18-30 1 - 18 30 μF 0,75 220x210x110 not required.
PFC-M 18-35 1 - 18 35 μF 0,75 220x210x110 It stops the pump in case of lack of air cushion in
the pressure vessel (patented system).
PFC-M 18-40 1 - 18 40 μF 1,1 220x210x110
Displayed operating data and alarms available in
PFC-M 18-50 1 - 18 50 μF 1,5 220x210x110 four languages.
PFC-M 18-60 1 - 18 60 μF 1,5 220x210x110
PFC-M 18-70 1 - 18 70 μF 2,2 220x210x110
QML/A 1 D Control panel for 1 pump with single-phase motor, direct starting
Type Motor 230V - 1~ Setting Dimensions Construction
Control panel for 1 pump with single-phase motor,
kW A HxBxP mm direct starting for pressure booster sets, with a
patented working time-measuring system that stops
QML/A 1 D 12A-FA 0,25 - 1,5 1 - 12 250x205x105 the pump in case of lack of air cushion in the
QML/A 1 D 12A-FA 20 0,25 - 1,5 1 - 12 250x205x105 pressure vessel.
QML/A 1 D 12A-FA 25 0,25 - 1,5 1 - 12 250x205x105 Arranged for the capacitor internal connection (for
pumps without built-in capacitor).
QML/A 1 D 3 FT 2,2 - 3 13 - 18 400x300x160
Pump operation controlled by an electronic
board type MPS 3000 with microprocessor which
allows three different modes of operation of the
pump: standard, emergency and timed.
PFC-T Control panel for 1 submersible pump with three-phase motor, PF control
Motor 400V - 3~ Setting Dimensions Construction
Type Control panel for controlling 1 submersible pump
kW A HxBxP mm with three-phase motor. Electronic control of the
operation and dry-running protection through the
PFC-T 16/A 0,37 - 5,5 1 - 16 250x205x105 power factor (PF) control.
The installation of level probes into the well is not
required.
It stops the pump in case of lack of air cushion in the
pressure vessel (patented system) Displayed operating
data and alarms, available in four languages.
QTL/A 1 D Control panel for 1 pump with three-phase motor, direct starting
QTL 1 D FTE Control panel for 1 pump with three-phase motor, direct starting
Motor Setting Dimensions Construction
Type
400V - 3~
Electromechanical control panel for 1 pump with
kW A HxBxP mm three-phase motor, direct starting.
QTL 1 D 4 FTE 4 6,3 - 10 400x300x160 Operating signals by E 1000 led card.
Dry-running protection with float switch.
QTL 1 D 5,5 FTE 5,5 9 - 12 400x300x160
Construction with SRLE level control for probes
QTL 1 D 7,5 FTE 7,5 13 - 18 400x300x160 connection against dry-running on request .
QTL 1 D 9,2 FTE 9,2 17 - 23 400x300x160
QTL 1 D 11 FTE 11 20 - 25 400x300x160
QTL 1 D 15 FTE 15 24 - 32 500x350x200
QTL 1 D 18,5 FTE 18,5 32 - 38 500x350x200
QTL 1 D 22 FTE 22 35 - 50 500x350x200
QTL 1 D 30 FTE 30 46 - 65 500x350x200
QTL/A 1 ST FT Control panel for 1 pump with three-phase motor, Y/Δ starting
Type Motor 400V - 3~ Dimensions Construction
Power Current Control panel for 1 pump with three-phase motor,
kW A HxBxP mm Y/Δ starting for pressure booster sets, with a
QTL/A 1 ST 5,5 FT 5,5 11 - 15 600x400x200 patented working time-measuring system that
QTL/A 1 ST 7,5 FT 7,5 12 - 17 600x400x200 stops the pump in case of lack of air cushion in
QTL/A 1 ST 11 FT 9,2 - 11 16 - 24 600x400x200 the pressure vessel.
QTL/A 1 ST 15 FT 15 23 - 31 600x400x200 Pump operation controlled by an electronic card
QTL/A 1 ST 18,5 FT 18,5 30 - 39 600x400x200 type MPS 3000 with microprocessor with
QTL/A 1 ST 22 FT 22 35 - 43 700x500x200 different pump operating modes.
QTL/A 1 ST 30B FT 30 42 - 55 700x500x200 Dry-running protection with float switch or level
QTL/A 1 ST 30A FT 30 55 - 65 700x500x200 control probes.
QTL/A 1 ST 37 FT 37 61 - 84 800x600x250
QTL/A 1 ST 45 FT 45 80 - 105 800x600x250
444
CS-R Submersible motors
QTL 1 ST FTE Control panel for 1 pump with three-phase motor, Y/Δ starting
Type Motor 400V - 3~ Dimensions Construction
Power Current Electromechanical control panel for 1 pump with
kW A HxBxP mm
three-phase motor, Y/Δ starting.
QTL 1 ST 5,5 FTE 5,5 11 - 15 500x350x200 Operating signals by E 1000 led board.
QTL 1 ST 7,5 FTE 7,5 12 - 17 500x350x200 Dry-running protection with float switch.
QTL 1 ST 11 FTE 9,2 - 11 16 - 24 500x350x200 Construction with SRLE level control for probes
QTL 1 ST 15 FTE 15 23 - 31 500x350x200 connection against dry-running on request .
QTL 1 ST 18,5 FTE 18,5 30 - 39 500x350x200
QTL 1 ST 22 FTE 22 35 - 43 600x400x200
QTL 1 ST 30B FTE 30 42 - 55 600x400x200
QTL 1 ST 30A FTE 30 55 - 65 600x400x200
QTL 1 ST 37 FTE 37 61 - 84 700x500x200
QTL 1 ST 45 FTE 45 80 - 105 700x500x200
QTL 1 ST 55 FTE 55 100 - 125 700x500x200
QTL 1 ST 75 FTE 75 120 - 160 800x600x250
QTL 1 ST 92 FTE 92 140 - 198 800x600x250
QTL 1 ST 110 FTE 110 180 - 250 800x600x250
QTL 1 SS E Control panel for 1 pump with three-phase motor, start/stop with soft starter
Type Motor Max current Dimensions Construction
400V - 3~ output Control panel for 1 pump with three-phase
kW max A HxBxP mm motor, start/stop with soft starter.
QTL 1 SS 7,5 E 7,5 17 700x500x250 Operating signals on E 1000 led board.
QTL 1 SS 15 E 9,2 - 11 - 15 30 700x500x250 Application: control of submersible motor with
QTL 1 SS 22 E 18,5 - 22 45 700x500x250 great cable length and surface motors.
QTL 1 SS 30 E 26 - 30 60 900x600x300 Dry-running protection with float switch.
QTL 1 SS 37 E 37 75 900x600x300 Construction with SRLE level control for probes
QTL 1 SS 45 E 45 85 900x600x300 connection against dry-running on request .
QTL 1 SS 55 E 55 110 900x600x300
QTL 1 SS 63 E 63 125 1100x700x300
QTL 1 SS 75 E 75 142 1100x700x300
QTL 1 SS 90 E 90 190 1200x800x400
QTL 1 SS 132 E 110 - 132 245 1200x800x400
QTL 1 IS FTE Control panel for 1 pump with three-phase motor, with Stator Impedence starter
Type Motor 400V - 3~ Dimensions Construction
Power Current Electromechanical control panel for 1
kW A HxBxP mm submersible pump with three-phase motor,
QTL 1 IS 5,5 FTE-2RL 5,5 11 - 15 with Stator Impedence starter.
QTL 1 IS 7,5 FTE-2RL 7,5 12 - 17 Operating signals on led board type E 1000.
QTL 1 IS 11 FTE-2RL 9,2 - 11 16 - 24 Application : submersible motors control with
QTL 1 IS 15 FTE-2RL 15 23 - 31 great cable length.
QTL 1 IS 18,5 FTE-2RL 18,5 30 - 39 Construction with SRLE level control for
QTL 1 IS 22 FTE-2RL 22 35 - 43 probes connection against dry-running .
QTL 1 IS 30 FTE-2RL 30 42- 65
QTL 1 IS 37 FTE-2RL 37 61 - 84
QTL 1 IS 45 FTE-2RL 45 80 - 105
QTL 1 IS 55 FTE-2RL 55 100 - 125
QTL 1 IS 75 FTE-2RL 75 120 - 160
QTL 1 IS 92 FTE-2RL 92 140 - 198
QTL 1 IS 110 FTE-2RL 110 180 - 250
445
CS-R Submersible motors
QML 1 VFT Control panel for 1 pump with variable speed three-phase motor
Type Motor Max current Dimensions Construction
230V - 3~ output HxBxP Single-phase mains supply control panel with
kW max A mm frequency converter for 1 pump with three-phase
variable speed motor, for constant pressure
QML 1 VFT 0,4 0,37 - 0,45 2,4 500x350x200
booster sets.
QML 1 VFT 0,75 0,55 - 0,75 4,2 500x350x200 Arranged for SRL 3 level control application for
QML 1 VFT 1,5 1,1 - 1,5 7,5 500x350x200 probes connection against dry-running.
QML 1 VFT 2,2 2,2 10 500x350x200 Pump operation controlled by an electronic board
type MPS 4000 with microprocessor.
QTL 1 VFT Control panel for 1 pump with variable speed three-phase motor
Type Motor Max current Dimensions Construction
400V - 3~ output HxBxP Control panel with frequency converter for 1
kW max A mm
pump with three-phase variable speed motor,
QTL 1 VFT 0,4 0,4 1,5 500x350x200 for constant pressure booster sets.
QTL 1 VFT 0,75 0,55 - 0,75 2,3 500x350x200 Arranged for SRL 3 level control application for
QTL 1 VFT 1,5 1,1 - 1,5 4,1 500x350x200 probes connection against dry-running.
QTL 1 VFT 2,2 2,2 5,5 500x350x200 Pump operation controlled by an electronic
QTL 1 VFT 4 3-4 9,5 500x350x200 board type MPS 4000 with microprocessor.
QTL 1 VFT 5,5 5,5 14,3 600x400x250
QTL 1 VFT 7,5 7,5 17 600x400x250
QTL 1 VFT 11 9,2 - 11 27,7 700x500x250
QTL 1 VFT 15 15 33 700x500x250
QTL 1 VFT 18,5 18,5 46,3 800x600x250
QTL 1 VFT 22 22 61,5 800x600x250
QTL 1 VFT 30 30 74,5 900x600x250
QTL 1 VFT 37 37 88 1100x700x300
QTL 1 VFT 45 45 106 1200x800x300
QTL 1 VFT 55 55 145 1200x800x300
QTL 1 VFT 75 75 173 1200x800x300
446
03/2021
NCE
Heating and conditioning
447
NCE EI NCE EL
pag. 450 pag. 479
NCE(D) H NCE ES
pag. 454 pag. 483
NCE(D) H F NCE PS
pag. 461 pag. 486
NCE(D) HQ F NCS3
pag. 468 pag. 490
NC3
pag. 493
448
ENERGY EFFICIENCY OF CIRCULATING PUMPS
Directive of the European Parliament COMMISSION REGULATION (EC) No 641/2009 and 622/2012
Eco-design Directive of Energy Using Products (ErP Directive - Energy-related Products). The
European Union wants to improve the design of equipment that "consume" significant energy e.g.
(televisions, refrigerators, washing machines, boilers, pumps, and motors etc.) To improve eco-
design providing environmental sustainability, reduducing negative environmental impact as the
consequence of production, use and disposal of products.
The objective of the Directive is to force manufacturers and importers to produce and distribute
products with high energy efficiency, and carbon output.
The criteria for eco-design will be an integral part of the declaration of conformity (CE), which is a
necessary requirement/mark for products being sold in the EU.
a
This Regulation shall apply to:
Stand-alone* or integrated** circulators with the motor immersed in the pumped medium, with
Energ e
i
y
hydraulic power from 1 up to 2500 W, designed for use in heating systems or in secondary cir-
cuits of cooling distribution systems.
EEI < 0,23 2015
EEI < 0,27 2013
* Stand alone circulators are commonly available on the market.
** circulators integrated in products are component of a device, such as boilers, heat
0,27 < EEI < 0,4 A
pumps, etc.. 0,4 < EEI < 0,6 B
0,6 < EEI < 0,8 C
This Regulation shall not apply to:
a) drinking water circulators 0,8 < EEI < 1,0 D
b) circulators integrated in products and placed on the market not later than 1 January 2020 as
replacement for identical circulators integrated in products and placed on the market no later
1,0 < EEI < 1,2 E
than 1 August 2015. The replacement product or its packaging must clearly indicate the 1,2 < EEI < 1,4 F
product(s) for which it is intended.
EEI < 1,4 G
Q
H
max
Constant speed curve
In this operating mode the pump works as a traditional pump with a constant curve, the
operating curve can be chosen by the user within a range of curves. RPMset
+
-
min
Q
449
NCE EI Energy saving circulating pumps
Construction
Energy saving variable speed circulating pump driven by a per-
manent magnet synchronous motor (pm) controlled by on
board inverter.
Applications
Small domestic heating systems.
Floor heating systems.
Operating conditions
- Liquid temperature from +2 °C to +95 °C
- Ambient temperature from 0 °C to +40 °C
- Maximum permissible working pressure: 6 bar
- Storage: -20°C/+70°C max. relative humidity 95% at 40 °C
- Certifications: in conformity with CE requirements
- Sound pressure ≤ 43 dB (A).
- Minimum suction pressure: 0,3 bar at 50 °C
1,0 bar at 95 °C
- Maximum glycol quantity: 40%
- EMC according to: EN 55014-1, EN 61000-3-2, EN 55014-2
- Connections: threaded ports ISO 228: G 1, G 1 1/2, G 2
- The benchmark for most efficient circulators is EEI ≤ 0,20.
- Minimun power: 3 W.
Motor
Synchronous motor with permanent magnet.
- Motor: variable speed
Designation
- Standard voltage: single-phase 230 V (-10%;+6%)
NCE EI 32 - 60 / 180 - Frequency: 50-60 Hz
Series - Protection: IP 44
- Insulation class: H
Version - Class II appliance
DN ports in mm - Overload protection (jammed rotor):
1) automatic protection with electronic rotor release
Max. head in dm
2) Overload thermal protector
connection size mm - Cable: phases and neutral
- Constructed in accordance with: EN 60335-1, EN 60335-2-51.
Features
Compact design
The space saving NCE EI is a very compact circulating pump, allows inr easy installation in small domestic heating systems.
Reliable
Like all our electronic circulating pumps, the NCE EI features the patented self-cleaning square chamber design, which eliminates any possibility of
rotor blockage.
Ceramic shaft
Hydraulics components are completely painted with cataphoresis.
Easy use
Operating range with fixed curves from 0,5 m to 7 m; possibility to choose 2 (1-2) proportional pressure curves and 2 (I-II) constant pressure curves.
450
NCE EI Energy saving circulating pumps
Operating modes
max
PROPORTIONAL CURVE PROGRAMMING Δp-v
(GREEN LED) min
Moving the switch to 1 or 2 setting, the pump operates with the proportional curve.
This mode ensures maximum energy efficiency.
(ORANGE LED)
Moving the switch to I or II setting, the pump operates with a constant curve according to the min
(BLUE LED)
min
Setting the switch in any position between the MIN and MAX points, the most suitable operating curve
for the installation is manually selected.
WARNING!
- The red LED indicates that the pump is not rotating but is still under tension.
- White flashing LED : plant degassing requirement, air in the system.
Characteristic curves
NCE EI 15-70
NCE EI 25-70
NCE EI 32-70
EEI ≤ 0,21
451
NCE EI Energy saving circulating pumps
Materials
fM
29,5 90
DN 45
a 88
13,2
DN
78
230V P1 mm
TYPE Unions (on request)
DN A max A min W max W min fm a kg
NCE EI 15-40/130 G1 1,67
0,17 0,03 22 3 134 130
NCE EI 25-40/130 G 1 1/2 1,81
NCE EI 25-40/180 G 1 1/2 1,96
0,17 0,03 22 3 134 180
NCE EI 32-40/180 G2 2,10 DN
NCE EI 15-60/130/A G1 1,67
0,33 0,03 42 3 134 130
NCE EI 25-60/130/A G 1 1/2 1,81
DN1
NCE EI 25-60/180/A G 1 1/2 1,96
0,33 0,03 42 3 134 180
NCE EI 32-60/180/A G2 2,10
G1 1,91 DN DN1
NCE EI 15-70/130
0,44 0,03 56 3 144 130
NCE EI 25-70/130 G 1 1/2 2,05 KIT G 1 - G 1/2 (NCE . 15..) G1 G 1/2
NCE EI 25-70/180 G 1 1/2 2,20 KIT G 1 1/2 - G 1 (NCE . 25..) G 1 1/2 G1
0,44 0,03 56 3 144 180
NCE EI 32-70/180 G2 2,34 KIT G 2 - G 1 1/4 (NCE . 32..) G2 G 1 1/4
452
NCE EI Energy saving circulating pumps
Examples of installations
Installation
12
9 3
453
NCE(D) H Energy saving circulating pumps
Construction
Energy saving variable speed circulating pump driven by a per-
manent magnet synchronous motor (pm) controlled by on
board inverter.
Applications
Heating and conditioning systems.
Operating conditions
- Liquid temperature from +2 °C to +110 °C
- Ambient temperature from 0 °C to +40 °C
- Maximum permissible working pressure: 10 bar
- Storage: -20°C/+70°C max. relative humidity 95% at 40 °C
- Certifications: in conformity with CE requirements
- Sound pressure ≤ 40 dB (A).
- Minimum suction pressure: - 0,05 bar at 75 °C
- 0,28 bar a 90 °C.
- Maximum glycol quantity: 20%.
- EMC according to: EN 55014-1, EN 55014-2
EN 61000-3-2, EN 61000-3-2.
- Connections: threaded ports ISO 228: G 1 1/2, G 2.
- The benchmark for most efficient circulators is EEI ≤ 0,20.
Motor
Synchronous motor with permanent magnet.
- Motor: variable speed
- Standard voltage: single-phase 230 V (-10%;+6%)
- Frequency: 50/60 Hz
- Protection: IP 44
- Insulation class: F
Designation - Overload protection (integrated).
- Cable: phases and neutral.
NCE(D) H 25 - 100 / 180
- Constructed in accordance with: EN 60335-1, EN 60335-2-51.
Series
Twin pumps version
Version Special features on request
Additional module (included with NCEDH):
DN ports in mm - Modbus
Max. head in dm - Eternet
- analog input 0-10V
connection size mm
- remote on/off input
- output relay
Features
Smart pump
NCE H adapt its functions to the system: the circulator measures the pressure and the flow and adjusts the speed to the selected pressure.
Easy use
There are different operating modes selectable from the control panel.
454
NCE(D) H Energy saving circulating pumps
Operating modes
Automatic mode
(factory setting):
In this mode the pump automatically sets the operating pressure, depending
on the hydraulic system. This mode is recommended in most systems.
P5
32
The circulator mantains the pressure constant when the reference flow
changes.
The pressure value can be adjusted with the + and - buttons.
Operating mode-control panel
Fixed speed mode:
NCE(D) H could works in:
The circulator works with constant curve and the curve could be changed
- automatic mode
using + e - buttons.
- proportional pressure mode
- constant pressure mode
- fixed speed mode
Night mode:. - night mode
When the liquid temperature fall by 15-20°C the pump automatically swiches to
night mode, in practice the circulator works at minimum curve. The night mode could be selected with any
When the temperature rises again the pump comes back to the selected mode operating mode.
The night mode could be selected with any operating mode.
Coverage chart
12
NCE(D) H
11 NCE(D) H ..-120
10
H NCE(D) H ..-100
m
8
NCE(D) H ..-80
7
5 NCE(D) H ..-60
3
NCE(D) H ..-40
2
0
0 Q m3/h 2 4 6 8 10 12
455
NCE(D) H Energy saving circulating pumps
Characteristic curves
Hm Hm
NCE H 25-40 NCE H 25-60
NCE(D) H 32-40 6 NCE(D) H 32-60
4
EEI ≤ 0,21 EEI ≤ 0,21
5
3
4
3
2
2
1
1
0 0
0 m3/h 2 3 4 5 6 7 8 0 m3/h 2 3 4 5 6 7 8 9 10
Q Q
0 l/min 50 100 0 l/min 50 100 150
PW PW
P1 max
50 100 P1 max
40 80
30 60
20 40
P1 min P1 min
10 20
0 0
0 Q m3/h 2 3 4 5 6 7 8 0 Q m3/h 2 3 4 5 6 7 8 9 10
Hm Hm
NCE H 25-80 12 NCE H 25-100
9
NCE(D) H 32-80 NCE(D) H 32-100
8
EEI ≤ 0,21 10 EEI ≤ 0,21
7
6 8
5
6
4
3 4
2
2
1
0 0
0 m3/h 2 4 6 8 10 12 0 m3/h 2 4 6 8 10 12
Q Q
0 l/min 50 100 150 200 0 l/min 50 100 150 200
PW PW
P1 max P1 max
140 180
120
160
100
80 120
60 80
40
20 40 P1 min
P1 min
0 0
0 Q m3/h 2 4 6 8 10 12 0 Q m3/h 2 4 6 8 10 12
456
NCE(D) H Energy saving circulating pumps
Characteristic curves
Hm
12 NCE H 25-120
NCE(D) H 32-120
10 EEI ≤ 0,21
0
0 m3/h 2 4 6 8 10 12
Q
0 l/min 50 100 150 200
PW
P1 max
180
160
120
80
40 P1 min
0
0 Q m3/h 2 4 6 8 10 12
457
NCE(D) H Energy saving circulating pumps
Materials
9 7 8
4 4
5 6
458
NCE H Energy saving circulationg pumps
Examples of installations
DN 190
117 Unions (on request)
H Q 1~ 230 V P1 a
TYPE
DN m m3/h A min A max W min W max mm kg
NCE H 25-40/180 G 1 1/2 4 DN
4 5 0,1 0,5 10 60 180
NCE H 32-40/180 G2 4,1
NCE H 25-60/180 G 1 1/2 4
6 7,5 0,1 0,75 10 90 180 DN1
NCE H 32-60/180 G2 4,1
NCE H 25-80/180 G 1 1/2 4
8 9 0,1 1,15 10 140 180
NCE H 32-80/180 G2 4,1 DN DN1
459
NCED H Energy saving circulationg pumps
Examples of installations
100
DN
90 90 190
Unions (on request)
297
H Q 1~ 230 V P1 a
TYPE
DN m m3/h A min A max W min W max mm kg
NCED H 32-40/180 DN
G2 4 5 0,1 0,5 10 60 180 8
460
Energy saving circulating pumps
NCE(D) H.F with flanges
Construction
Energy saving variable speed circulating pump driven by a per-
manent magnet synchronous motor (pm) controlled by on
board inverter.
Applications
Heating and conditioning systems.
Operating conditions
- Liquid temperature from +2 °C to +110 °C
- Ambient temperature from 0 °C to +40 °C
- Maximum permissible working pressure: 10 bar
- Storage: -20°C/+70°C max. relative humidity 95% at 40 °C
- Certifications: in conformity with CE requirements
- Sound pressure ≤ 40 dB (A).
- Minimum suction pressure: - 0,05 bar at 75 °C
- 0,28 bar a 90 °C.
- Maximum glycol quantity: 20%.
- EMC according to: EN 55014-1, EN 55014-2
EN 61000-3-2, EN 61000-3-2.
- Connections: Flanges according to PN 6/10, EN 1092-2,
DN 32, 40, 50.
- The benchmark for most efficient circulators is EEI ≤ 0,20.
Motor
Synchronous motor with permanent magnet.
- Motor: variable speed
- Standard voltage: single-phase 230 V (-10%;+6%)
- Frequency: 50/60 Hz
- Protection: IP 44
- Insulation class: F
Designation - Overload protection (integrated).
- Cable: phases and neutral.
NCE(D) H 40 F - 60 / 220
- Constructed in accordance with: EN 60335-1, EN 60335-2-51.
Series
Twin pumps version
Version Special features on request
Additional module (included with NCEDH. F):
DN ports in mm - Modbus
With flanges - Eternet
- analog input 0-10V
Max. head in dm
- remote on/off input
connection size mm - output relay
Features
Smart pump
NCE H.F adapt its functions to the system: the circulator measures the pressure and the flow and adjusts the speed to the selected pressure.
Easy use
There are different operating modes selectable from the control panel.
461
Energy saving circulating pumps
NCE(D) H.F with flanges
Operating modes
Automatic mode
(factory setting):
In this mode the pump automatically sets the operating pressure, depending
on the hydraulic system. This mode is recommended in most systems.
P5
32
The circulator mantains the pressure constant when the reference flow
changes.
The pressure value can be adjusted with the + and - buttons.
Operating mode-control panel
Fixed speed mode:
NCE(D) H.F could works in:
The circulator works with constant curve and the curve could be changed
- automatic mode
using + e - buttons.
- proportional pressure mode
- constant pressure mode
- fixed speed mode
Night mode:. - night mode
When the liquid temperature fall by 15-20°C the pump automatically swiches to
night mode, in practice the circulator works at minimum curve. The night mode could be selected with any
When the temperature rises again the pump comes back to the selected mode operating mode.
The night mode could be selected with any operating mode.
Coverage chart
12
NCE(D) H.F
11 NCE(D) H.F ..-120
10
8
NCE(D) H.F ..-80
7
3
NCE(D) H.F ..-40
2
0
0 Q m3/h 2 4 6 8 10 12
462
Energy saving circulating pumps
NCE(D) H.F with flanges
Characteristic curves
Hm Hm
NCE H 32F-40 NCE H 32F-60
NCE(D) H 40F-40 6 NCE(D) H 40F-60
4 NCE H 50F-40 NCE H 50F-60
EEI ≤ 0,21 5 EEI ≤ 0,21
3
4
3
2
2
1
1
0 0
0 m3/h 2 3 4 5 6 7 8 0 m3/h 2 3 4 5 6 7 8 9 10
Q Q
0 l/min 50 100 0 l/min 50 100 150
PW PW
P1 max
50 100 P1 max
40 80
30 60
20 40
P1 min P1 min
10 20
0 0
0 Q m3/h 2 3 4 5 6 7 8 0 Q m3/h 2 3 4 5 6 7 8 9 10
Hm Hm
NCE H 32F-80 12 NCE H 32F-100
9 NCE(D) H 40F-80 NCE(D) H 40F-100
8 NCE H 50F-80 NCE H 50F-100
10
EEI ≤ 0,21 EEI ≤ 0,21
7
6 8
5
6
4
3 4
2
2
1
0 0
0 m3/h 2 4 6 8 10 12 0 m3/h 2 4 6 8 10 12
Q Q
0 l/min 50 100 150 200 0 l/min 50 100 150 200
PW PW
P1 max P1 max
140 180
120
160
100
80 120
60 80
40
20 40 P1 min
P1 min
0 0
0 Q m3/h 2 4 6 8 10 12 0 Q m3/h 2 4 6 8 10 12
463
Energy saving circulating pumps
NCE(D) H.F with flanges
Characteristic curves
Hm
12 NCE H 32F-120
NCE(D) H 40F-120
NCE H 50F-120
10
EEI ≤ 0,21
0
0 m3/h 2 4 6 8 10 12
Q
0 l/min 50 100 150 200
PW
P1 max
180
160
120
80
40 P1 min
0
0 Q m /h 2
3
4 6 8 10 12
464
Energy saving circulating pumps
NCE(D) H.F with flanges
Materials
9 7 8
4 4
5 6
465
Energy saving circulating pumps
NCE(D) H.F with flanges
Examples of installations
100
DN
53 190 DG
DK
DN 243 DK
117 DE
H Q 1~ 230 V P1 a holes
fori
TYPE
DN m m 3/h A min A max W min W max mm kg DN DE DK DG
N. Ø
NCE H 32F-40/220 32 220 7,4 32 140 90/100 74 4 14/19
NCE H 40F-40/220 40 4 5 0,1 0,5 10 60 220 8,5
40 150 100/110 80 4 14/19
NCE H 50F-40/240 50 240 9,8
50 165 110/125 90 4 14/19
NCE H 32F-60/220 32 220 7,4
NCE H 40F-60/220 40 5 7,5 0,1 0,75 10 90 220 8,5
NCE H 50F-60/240 50 240 9,8
NCE H 32F-80/220 32 220 7,4
NCE H 40F-80/220 40 8 9 0,1 1,15 10 140 220 8,5
NCE H 50F-80/240 50 240 9,8
NCE H 32F-100/220 32 220 7,4
NCE H 40F-100/220 40 10 11 0,1 1,5 10 180 220 8,5
NCE H 50F-100/240 50 240 9,8
NCE H 32F-120/220 32 220 7,9
NCE H 40F-120/220 40 12 15 0,1 1,5 10 180 220 8,7
NCE H 50F-120/240 50 240 10
466
Energy saving circulating pumps
NCE(D) H.F with flanges
Examples of installations
100
DN
53 190 DG
DN DK
90 90 243
DK
297 DE
H Q 1~ 230 V P1 a holes
fori
TYPE
DN m m 3/h A min A max W min W max mm kg DN DE DK DG
N. Ø
NCED H 40F-40/220 40 4 5 0,1 0,5 10 60 220 11,3 32 140 90/100 74 4 14/19
40 150 100/110 80 4 14/19
50 165 110/125 90 4 14/19
NCED H 40F-60/220 40 5 7,5 0,1 0,75 10 90 220 11,3
467
Energy saving twin circulating
NCE(D) HQ.F pumps with flanges
Construction
Energy saving variable speed circulating pump driven by a per-
manent magnet synchronous motor (pm) controlled by on
board inverter.
Applications
Heating and conditioning systems.
Operating conditions
- Liquid temperature from +2 °C to +110 °C
- Ambient temperature from 0 °C to +40 °C
- Maximum permissible working pressure: 10 bar
- Storage: -20°C/+70°C max. relative humidity 95% at 40 °C
- Certifications: in conformity with CE requirements
- Sound pressure ≤ 40 dB (A).
- Minimum suction pressure: - 0,05 bar at 75 °C
- 0,28 bar a 90 °C.
- Maximum glycol quantity: 20%.
- EMC according to: EN 55014-1, EN 55014-2
EN 61000-3-2, EN 61000-3-2.
- Connections: Flanges according to PN 6/10, EN 1092-2,
DN 32,40,50,65,80,100.
- The benchmark for most efficient circulators is EEI ≤ 0,20.
Designation Motor
NCE (D) HQ 40 F - 120 / 220 Synchronous motor with permanent magnet.
- Motor: variable speed
Series - Standard voltage: single-phase 230 V (-10%;+6%)
Twin pumps version - Frequency: 50/60 Hz
- Protection: IP 44
Version
- Insulation class: F
DN ports in mm - Overload protection (integrated).
With flanges - Cable: phases and neutral.
- Constructed in accordance with: EN 60335-1, EN 60335-2-51.
Max. head in dm
connection size mm
Features
Smart pump
NCE(D) HQ.F adapt its functions to the system: the circulator measures the pressure and the flow and adjusts the speed to the selected pressure.
Easy use
There are different operating modes selectable from the control panel.
468
Energy saving twin circulating
NCE(D) HQ.F pumps with flanges
Operating modes
Automatic mode
(factory setting):
In this mode the pump automatically sets the operating pressure, depending
on the hydraulic system. This mode is recommended in most systems.
P5
32
The circulator mantains the pressure constant when the reference flow
changes.
The pressure value can be adjusted with the + and - buttons.
Operating mode-control panel
Fixed speed mode:
NCE HQ.F could works in:
The circulator works with constant curve and the curve could be changed
- automatic mode
using + e - buttons.
- proportional pressure mode
- constant pressure mode
- fixed speed mode
Night mode:. - night mode
When the liquid temperature fall by 15-20°C the pump automatically swiches to
night mode, in practice the circulator works at minimum curve. The night mode could be selected with any
When the temperature rises again the pump comes back to the selected mode operating mode.
The night mode could be selected with any operating mode.
Coverage chart
20
18 NCE(D) HQ.F
16
14
40
/18
0
12 100/
120
10
H
m
8
32
80
/12
10 /12
0/8
40
0
0 0
/12
6
40
0
/80
80
-1
65 00
/80 /18
4 50 0
/1
80- 80
100 80
50/ /40 50 /80
40 /1 65
20 /12
2 0
40
50
65
/4
65/ /80
40
0
/1
80
0
0 Q m3/h 10 20 30 40 50 60 70
469
Energy saving twin circulating
NCE(D) HQ.F pumps with flanges
Characteristic curves
13
12 NCE(D) HQ 32F-120
11 EEI ≤ 0,22
10
9
8
7
H (m)
6
5
4
3
2
1
0
0 (m3/h) 5 10 15 20 25
Q
0 (l/min) 100 200 300 400
400
300
P (W)
200
100
0
0 Q (m3/h) 5 10 15 20 25
470
Energy saving twin circulating
NCE(D) HQ.F pumps with flanges
Characteristic curves
5 9
NCE(D) HQ 40F-40 NCE(D) HQ 40F-80
8
EEI ≤ 0,21 EEI ≤ 0,21
4 7
6
3
5
H (m)
H (m)
4
2
3
2
1
1
0 0
0 (m3/h) 3 4 5 6 7 8 9 10 11 12 13 14 0 (m3/h) 6 8 10 12 14 16 18 20
Q Q
0 (l/min) 100 200 0 (l/min) 100 200 300
120 300
100 250
80 200
P (W)
P (W)
60 150
40 100
20 50
0 0
0 Q (m3/h) 3 4 5 6 7 8 9 10 11 12 13 14 0 Q (m3/h) 4 6 8 10 12 14 16 18 20
13 18
12 NCE(D) HQ 40F-120 17 NCE(D) HQ 40F-180
16
11 EEI ≤ 0,21 15 EEI ≤ 0,23
10 14
13
9
12
8 11
7 10
H (m)
H (m)
9
6 8
5 7
4 6
5
3 4
2 3
2
1
1
0 0
0 (m3/h) 6 8 10 12 14 16 18 20 22 24 0 (m3/h) 6 8 10 12 14 16 18 20 22 24 26
Q Q
0 (l/min) 100 200 300 400 0 (l/min) 100 200 300 400
600 700
500 600
400 500
P (W)
P (W)
400
300
300
200
200
100 100
0 0
0 Q (m3/h) 6 8 10 12 14 16 18 20 22 24 0 Q (m3/h) 6 8 10 12 14 16 18 20 22 24 26
471
Energy saving twin circulating
NCE(D) HQ.F pumps with flanges
Characteristic curves
5 9
NCE(D) HQ 50F-40 NCE(D) HQ 50F-80
8
EEI ≤ 0,23 EEI ≤ 0,22
4 7
6
3
5
H (m)
H (m)
4
2
3
1 2
0 0
0 (m3/h) 6 8 10 12 14 16 18 20 22 24 26 0 (m3/h) 10 20 30 36
Q Q
0 (l/min) 100 200 300 400 0 (l/min) 200 300 400 500 600
180 400
160
140 300
120
P (W)
P (W)
100 200
80
60
40 100
20
0 0
0 Q (m3/h) 6 8 10 12 14 16 18 20 22 24 26 0 Q (m3/h) 10 20 30 36
14 17
13 NCE(D) HQ 50F-120 16 NCE(D) HQ 50F-180
12 15
EEI ≤ 0,21 14 EEI ≤ 0,23
11 13
10 12
9 11
8 10
9
H (m)
H (m)
7
8
6 7
5 6
4 5
3 4
3
2
2
1 1
0 0
0 (m3/h) 10 20 30 40 0 (m3/h) 10 15 20 25 30 35 40 45
Q Q
0 (l/min) 200 300 400 500 600 0 (l/min) 200 300 400 500 600 700
600
500 800
400 600
P (W)
P (W)
300
400
200
100 200
0 0
0 Q (m3/h) 10 20 30 40 0 Q (m3/h) 10 15 20 25 30 35 40 45
472
Energy saving twin circulating
NCE(D) HQ.F pumps with flanges
Characteristic curves
5 9
NCE(D) HQ 65F-40 NCE(D) HQ 65F-80
8
EEI ≤ 0,23 EEI ≤ 0,22
4 7
6
3
5
H (m)
H (m)
4
2
3
1 2
0 0
(m3/h) 6
0 8 10 12 14 16 18 20 22 24 26 28 30 32 0 (m3/h) 10 15 20 25 30 35 40 45
Q Q
0 (l/min) 200 300 400 500 0 (l/min) 200 300 400 500 600 700
250 600
200 500
400
P (W)
P (W)
150
300
100
200
50 100
0 0
0 Q (m3/h) 6 8 10 12 14 16 18 20 22 24 26 28 30 32 0 Q (m3/h) 10 15 20 25 30 35 40 45
13 Hm
10
6
8
5
4 6
3 4
2
2
1
0 0
0 m3 /h 20 30 40 50 60 70
0 (m3/h) 10 15 20 25 30 35 40 45 50 Q
Q l/min 100
0 (l/min) 200 300 400 500 600 700 800 0 200 300 400 500
PW
800 2000
P1 max
600 1600
P (W)
1200
400
800
200 400
0 0
0 Q (m3/h) 10 15 20 25 30 35 40 45 50 0 Q m3 /h 20 30 40 50 60 70
473
Energy saving twin circulating
NCE(D) HQ.F pumps with flanges
Characteristic curves
5 9
NCE(D) HQ 80F-40 NCE(D) HQ 80F-80
8
EEI ≤ 0,22 EEI ≤ 0,23
4 7
6
3
5
H (m)
H (m)
4
2
3
1 2
0 0
0 (m3/h) 10 15 20 25 30 35 40 0 (m3/h) 10 15 20 25 30 35 40 45 50 55
Q Q
0 (l/min) 200 300 400 500 600 0 (l/min) 200 300 400 500 600 700 800 900
400 800
300 600
P (W)
P (W)
200 400
100 200
0 0
0 Q (m3/h) 10 15 20 25 30 35 40 0 Q (m3/h) 10 15 20 25 30 35 40 45 50 55
Hm Hm
14 NCE(D) HQ 80F-120 18 NCE(D) HQ 80F-180
EEI ≤ 0,20 16 EEI ≤ 0,20
12
14
10
12
8
10
6 8
6
4
4
2 2
0 0
0 m3/h10 20 30 40 50 60 70 80 0 m3 /h 20 30 40 50 60 70
Q Q
0 l/min 500 1000 0 l/min 100 200 300 400 500
PW PW
2000 2000
P1 max P1 max
1600 1600
1200 1200
800 800
400 400
P1 min
0 0
0 Q m3/h10 20 30 40 50 60 70 80 0 Q m3 /h 20 30 40 50 60 70
474
Energy saving twin circulating
NCE(D) HQ.F pumps with flanges
Characteristic curves
5 9
NCE(D) HQ 100F-40 NCE(D) HQ 100F-80
8
EEI ≤ 0,20 EEI ≤ 0,20
4 7
6
3
5
H (m)
H (m)
4
2
3
1 2
0 0
0 (m3/h) 10 15 20 25 30 35 40 0 (m3/h)10 20 30 40 50 60
Q Q
0 (l/min) 200 300 400 500 600 0 (l/min) 200 300 400 500 600 700 800 900 1000
400 1600
300 1200
P (W)
P (W)
200 800
100 400
0 0
0 Q (m3/h) 10 15 20 25 30 35 40 0 Q (m3/h)10 20 30 40 50 60
Hm Hm
14 NCE(D) HQ 100F-120 18 NCE(D) HQ 100F-180
EEI ≤ 0,20 16 EEI ≤ 0,20
12
14
10
12
8
10
6 8
6
4
4
2 2
0 0
0 m3/h10 20 30 40 50 60 70 80 0 m3 /h 20 30 40 50 60 70
Q Q
0 l/min 500 1000 0 l/min 100 200 300 400 500
PW PW
2000 2000
P1 max P1 max
1600 1600
1200 1200
800 800
400 400
P1 min
0 0
0 Q m3/h10 20 30 40 50 60 70 80 0 Q m3 /h 20 30 40 50 60 70
475
Energy saving twin circulating
NCE(D) HQ.F pumps with flanges
Materials
9 7 8
4 4
5 6
476
Energy saving circulating pumps
NCE HQ.F with flanges
Ø
DN
Ø
DN DN
DG DG
a DK DK
DK DE
DE
J1
fori
holes
DN DE DK DG
N. Ø
32 140 90/100 74 4 14/19
40 150 100/110 80 4 14/19
h1 h6
50 165 110/125 90 4 14/19
DN FM 65 185 130/145 110 4 14/19
l1 l2
80 200 160 148 8 19
AL1 DN AR1 AL AR 100 220 180 166 8 19
H Q 1~ P1 mm
TYPE 230 V
DN m m3/h A max W max a J1 FM h1 h6 l1 l2 AL AR AL1 AR1 kg
NCE HQ 32F-120/220 32 12 19 1.8 370 220 115 330 65 265 75 75 - - - - 9,1
NCE HQ 40F-40/250 40 4 13 1 110 250 99 270 65 205 59 74 - - - - 8,2
NCE HQ 40F-80/250 40 8 19 1.3 270 250 115 330 65 265 75 75 - - - - 9,6
NCE HQ 40F-120/250 40 12 24 2.3 480 250 115 330 65 265 75 75 - - - - 9,95
NCE HQ 40F-180/250 40 18 25 3.4 680 250 115 330 65 265 - - 90 90 - - 14,2
NCE HQ 50F-40/280 50 4 23 1.3 160 280 99 313 65 241 74 92 - - - - 10,8
NCE HQ 50F-80/280 50 8 32 1.7 370 280 115 373 72 301 75 92 - - - - 12,35
NCE HQ 50F-120/280 50 12 36 2.5 560 280 115 373 72 301 75 92 - - - - 13
NCE HQ 50F-180/280 50 18 42 3.6 830 280 115 383 72 311 - - 92 90 - - 15,9
NCE HQ 65F-40/340 65 4 31 1.1 230 340 115 386 75 311 83 100 - - - - 15,95
NCE HQ 65F-80/340 65 8 43 2.6 560 340 115 386 75 311 83 103 - - - - 16,65
NCE HQ 65F-120/340 65 12 50 3.5 810 340 115 397 75 322 - 103 90 - - - 19,3
NCE HQ 65F-180/340 65 18 57 6,6 1550 340 137 434 75 359 - - - - 94,5 104 -
NCE HQ 80F-40/360 80 4 40 1.8 390 360 115 414 93 321 98 123 - - - - 23,4
NCE HQ 80F-80/360 80 8 53 3.5 800 360 115 425 93 332 98 123 - - - - 25,8
NCE HQ 80F-120/360 80 12 69 6,0 1400 360 137 462 93 369 - - - - 98,5 124 -
NCE HQ 80F-180/360 80 18 72 6,6 1550 360 137 462 93 369 - - - - 98,5 124 -
NCE HQ 100F-40/450 100 4 40 2.4 550 450 115 424 103 321 98 123 - - - - -
NCE HQ 100F-80/450 100 8 59 4,7 1150 450 137 472 103 369 - - - - 110 124 -
NCE HQ 100F-120/450 100 12 72 6,6 1550 450 137 472 103 369 - - - - 110 124 -
NCE HQ 100F-180/450 100 18 72 6,6 1550 450 137 472 103 369 - - - 110 124 -
Examples of installations
477
Energy saving twin circulating
NCE(D) HQ.F pumps with flanges
DN 32,40,50, 65 DN 80,100
PN6/10 PN10
DN
Ø
DN
Ø
DN DN
DG DG
a DK DK
DK DE
J1
DE
fori
holes
DN DE DK DG
N. Ø
h1 h6
32 140 90/100 74 4 14/19
DN FM 40 150 100/110 80 4 14/19
DN l1 l2
50 165 110/125 90 4 14/19
AL1 AR1
AL AR 65 185 130/145 110 4 14/19
80 200 160 148 8 19
100 220 180 166 8 19
H Q 1~ P1 mm
TYPE 230 V
DN m 3
m /h A max W max a J1 FM h1 h6 l1 l2 AL AR AL1 AR1 kg
NCED HQ 32F-120/220 32 12 19 1.8 370 220 115 330 65 265 - - 185 186 - - -
NCED HQ 40F-40/250 40 4 13 1 110 250 99 270 65 205 181 186 - - - - 14,3
NCED HQ 40F-80/250 40 8 19 1.3 270 250 115 330 65 265 - - 185 186 - - 16,7
NCED HQ 40F-120/250 40 12 24 2.3 480 250 115 330 65 265 - - 185 186 - - 16,9
NCED HQ 40F-180/250 40 18 25 3.4 680 250 115 390 65 325 - - 200 200 - - 25
NCED HQ 50F-40/280 50 4 23 1.3 160 280 99 313 72 241 199 200 - - - - 19,6
NCED HQ 50F-80/280 50 8 32 1.7 370 280 115 373 72 301 199 200 - - - - 22,4
NCED HQ 50F-120/280 50 12 36 2.5 560 280 115 373 72 301 199 200 - - - - 23,6
NCED HQ 50F-180/280 50 18 42 3.6 830 280 115 373 72 311 - 203 200 - - - 28,8
NCED HQ 65F-40/340 65 4 31 1.1 230 340 115 384 75 309 216 226 - - - - 32,2
NCED HQ 65F-80/340 65 8 43 2.6 560 340 115 384 75 309 216 226 - - - - 32,7
NCED HQ 65F-120/340 65 12 50 3.5 810 340 115 395 75 320 216 226 - - - - 38,4
NCED HQ 65F-180/340 65 18 57 6,6 1550 340 137 432 75 357 - - - - 216 226 -
NCED HQ 80F-40/360 80 4 40 1.8 390 360 115 414 93 321 241 253 - - - - -
NCED HQ 80F-80/360 80 8 53 3.5 800 360 115 425 93 332 241 253 - - - - -
NCED HQ 80F-120/360 80 12 69 6,0 1400 360 137 462 93 369 - - - - 241 253 -
NCED HQ 80F-180/360 80 18 72 6,6 1550 360 137 462 93 369 - - - - 241 253 -
NCED HQ 100F-40/450 100 4 40 2.4 550 450 115 424 103 321 241 253 - - - - -
NCED HQ 100F-80/450 100 8 59 4,7 1150 450 137 472 103 369 - - - - 241 253 -
NCED HQ 100F-120/450 100 12 72 6,6 1550 450 137 472 103 369 - - - - 241 253 -
NCED HQ 100F-180/450 100 18 72 6,6 1550 450 137 472 103 369 - - - - 241 253 -
Examples of installations
478
Energy saving circulating pumps
NCE EL for solar systems
Construction
Energy saving variable speed circulating pump driven by a per-
manent magnet synchronous motor (pm) controlled by on
board inverter.
Applications
Solar thermal systems.
Operating conditions
- Liquid temperature from +2 °C to +110 °C
- Ambient temperature from 0 °C to +40 °C
- Maximum permissible working pressure: 10 bar
- Storage: -20°C/+70°C max. relative humidity 95% at 40 °C
- Certifications: in conformity with CE requirements
- Sound pressure ≤ 43 dB (A).
- Minimum suction pressure: 0,3 bar at 50 °C
1,0 bar at 95 °C
1,5 bar at 110 °C
- Maximum glycol quantity: 40%
- EMC according to: EN 55014-1, EN 61000-3-2, EN 55014-2
- Connections: threaded ports ISO 228: G 1, G 1 1/2.
- The benchmark for most efficient circulators is EEI ≤ 0,20.
- Minimun power: 3 W.
Motor
Synchronous motor with permanent magnet.
Designation - Motor: variable speed
NCE EL 25 - 60 / 180 - Standard voltage: single-phase 230 V (-10%;+6%)
Series - Frequency: 50-60 Hz
- Protection: IP 44
Version - Insulation class: H
DN ports in mm - Class II appliance
- Overload protection (jammed rotor):
Max. head in dm
1) automatic protection with electronic rotor release
connection size mm 2) Overload thermal protector
- Cable: phases and neutral
- Constructed in accordance with: EN 60335-1, EN 60335-2-51.
Features
Compact design
The space saving NCE EL is a very compact circulating pump, allows inr easy installation in small domestic heating systems.
Reliable
Like all our electronic circulating pumps, the NCE EL features the patented self-cleaning square chamber design, which eliminates any possibility of
rotor blockage.
Ceramic shaft.
Hydraulics components are completely painted with cataphoresis.
Program for automatic routine vent and release.
Easy use
Operating range with fixed curves from 0,6 m to 7 m; possibility to choose proportional pressure curve or selection of the optimum working point.
479
Energy saving circulating pumps
NCE EL for solar systems
Operating modes
MANUAL PROGRAMMING
(BLUE LED) max
Setting the switch in any position between the MIN and MAX points, the most suitable operating curve
for the installation is manually selected.
min
WARNING!
- The red LED indicates that the pump is not rotating but is still under tension.
- White flashing LED : plant degassing requirement, air in the system.
Characteristic curves
NCE EL 15-70
NCE EL 15-60 NCE EL 25-70
NCE EL 25-60
EEI ≤ 0,21
EEI ≤ 0,20
P proportional curve
min-max n fixed curves
480
Energy saving circulating pumps
NCE EL for solar systems
Materials
fM
29,5 90
DN 45
a 88
13,2
DN
78
DN
230V P1 mm
TYPE
DN A max A min W max W min fm a kg
G1 DN1
NCE EL 15-60/130/A 1,67
0,33 0,03 42 3 134 130
NCE EL 25-60/130/A G 1 1/2 1,81
NCE EL 25-60/180/A G 1 1/2 0,33 0,03 42 3 134 180 1,96 DN DN1
NCE EL 15-70/130 G1 1,91 KIT G 1 - G 1/2 (NCE . 15..) G1 G 1/2
0,44 0,03 56 3 144 130
NCE EL 25-70/130 G 1 1/2 2,05
KIT G 1 1/2 - G 1 (NCE . 25..) G 1 1/2 G1
NCE EL 25-70/180 G 1 1/2 0,44 0,03 56 3 144 180 2,20
KIT G 2 - G 1 1/4 (NCE . 32..) G2 G 1 1/4
481
Energy saving circulating pumps
NCE EL for solar systems
Examples of installations
Installation
12
9 3
482
Energy saving circulating pumps
NCE ES for sanitary hot water
Construction
Energy saving variable speed circulating pump driven by a per-
manent magnet synchronous motor (pm) controlled by on
board inverter. Bronze pump casing.
Applications
Hot sanitary water systems.
Operating conditions
- Liquid temperature from +2 °C to +95 °C
- Ambient temperature from +2 °C to +40 °C
- Maximum working pressure: 10 bar
- Storage: -20°C/+70°C UR 95% a 40 °C
- Certifications: in conformity with CE requirements
- Sound pressure ≤ 43 dB (A).
- Minimum suction pressure: 0,3 bar at 50 °C
1,0 bar at 95 °C
- EMC according to: EN 55014-1, EN 55014-2, EN 61000-3-2,
EN 61000-3-3.
- Threated ports ISO 228: G 1, G 1 1/4, G 1 1/2.
Motor
Synchronous motor with permanent magnets.
Designation - Motor: variable speed
NCE ES 25 - 40 / 130 - Standard voltage: single-phase 230 V (-10%;+6%)
- Frequency: 50-60 Hz
Series
- Protection: IP 44
Version - Insulation class: H
DN ports in mm - Class II appliance
- Overload protection (jammed rotor):
Max. head in dm
1) automatic protection with electronic rotor release
connection size mm 2) overload thermal protector
- Cable: phases and neutral
- Constructed in accordance with: EN 60335-1, EN 60335-2-51.
Features
Energy saving
NCE ES is an high energy efficiency product.
Patented
Compact design
The space saving NCE ES facilitate the installation in the smaller systems.
Reliability
NCES features the patented self-cleaning square chamber design, which eliminates any possibility of rotor blockage. Escape routes for
impurities inside the
rotor chamber
Easy use
Operating range with fixed curves from 0,6 m to 4 m with selection of the optimum working point.
483
Energy saving circulating pumps
NCE ES for sanitary hot water
Operating modes
MANUAL PROGRAMMING
max
(BLUE LED)
Setting the switch in any position between the MIN and MAX points, the most suitable operating curve
for the installation is manually selected.
min
WARNING!
- The red LED indicates that the pump is not rotating but is still under tension.
- White flashing LED : plant degassing requirement, air in the system.
Characteristic curves
NCE ES 15-40 14
4 NCE ES 20-40
NCE ES 25-40
12
3 10
2
6
4
1
0 0
484
Energy saving circulating pumps
NCE ES for sanitary hot water
Materials
Examples of installations
12
9 3
DN 45
a 88
Unions (on request)
13,2
DN
DN
88
DN1
230V P1 mm Net
TYPE weight
DN A max A min W max W min a TYPE DN DN1
kg
NCE ES 15-40/130 G1 0,35 0,03 44 4,5 130 2,15 KIT G 1 - G 1/2 (NCE ES 15..) G1 G 1/2
NCE ES 20-40/130 G 1 1/4 0,35 0,03 44 4,5 130 2,25 KIT G 1 1/4 - G 3/4 (NCE ES 20..) G 1 1/4 G 3/4
NCE ES 25-40/130 G 1 1/2 0,35 0,03 44 4,5 130 2,35 KIT G 1 1/2 - G 1 (NCE ES 25..) G 1 1/2 G1
485
Energy saving circulating pumps
NCE PS for sanitary hot water
Construction
Energy saving variable speed circulating pump driven by a per-
manent magnet synchronous motor (pm) controlled by on
board inverter. Bronze pump casing.
Applications
Sanitary hot water systems.
Operating conditions
- Liquid temperature from +5 °C to +65 °C
- Ambient temperature from 0 °C to +40 °C
- Maximum permissible working pressure: 10 bar
- Storage: -20°C/+70°C max. relative humidity 95% at 40 °C
- Certifications: in conformity with CE requirements
- Sound pressure ≤ 38 dB (A).
- Minimum suction pressure: - 0,05 bar at 75 °C
- 0,28 bar a 90 °C.
- Maximum glycol quantity: 20%.
- EMC according to: EN 55014-1, EN 55014-2
EN 61000-3-2, EN 61000-3-2.
- Connections: threaded ports ISO 228: G 1 1/4, G 1 1/2.
Motor
Designation Synchronous motor with permanent magnet.
- Motor: variable speed
NCE PS 25 - 60 / 180
- Standard voltage: single-phase 230 V (-10%;+6%)
- Frequency: 50-60 Hz
Series
- Protection: IP 44
Version for sanitary hot water - Insulation class: F
DN ports in mm - Overload protection (integrated).
- Cable: phases and neutral.
Max. head in dm - Constructed in accordance with: EN 60335-1, EN 60335-2-51.
connection size mm
Features
Easy adjustment
The adjustment is simple and intuitive thanks to the LED indicator.
Easy use
3 proportional curves and 3 fixed speed curves are available and selectable by the button.
486
Energy saving circulating pumps
NCE PS for sanitary hot water
Operating modes
Coverage chart
10
H
m NCE PS
8
7
NCE PS ..-80
5
NCE PS ..-60
3
NCE PS ..-40
0
0 Q m3/h 1 2 3 4 5
487
Energy saving circulating pumps
NCE PS for sanitary hot water
Characteristic curves
Hm Hm
NCE PS 20-40 6 NCE PS 20-60
4 NCE PS 25-40 NCE PS 25-60
5
3 P3
P3 4
P2
P2
2 3
P1
P1
2
1
1
0 0
0 m3/h 1 2 3 0 m3/h 1 2 3
Q Q
0 l/min 10 20 30 40 50 0 l/min 10 20 30 40 50
PW PW
50
25
40
20
30
15
10 20
5 10
0 0
0 Q m3/h 1 2 3 0 Q m3/h 1 2 3
Hm
NCE PS 20-80
8 NCE PS 25-80
6
P3
P2
4
P1
0
0 m 3/h 1 2 3 4 5
Q
0 l/min 20 30 40 50 60 70 80 90
PW
50
40
30
20
10
0
3
0 Q m /h 1 2 3 4 5
488
Energy saving circulating pumps
NCE PS for sanitary hot water
Materials
9 8
1
Component Pos. Material
Pump casing 1 Bronze 7
2
Impeller 2 Composite
Shaft 3 Stainless steel AISI 420 3
Bearings 4 Carbon
Thrust bearing 5 Ceramic
Rotor 6 Stainless steel jacket
Winding 7 Copper wire
Electronic card 8 -
Gasket 9 EPDM 4 4
5 6
Examples of installations
128
DN 20
DN
DN
80 108 DN1
48
489
NCS3 Circulating pumps for sanitary hot water
Construction
Bronze pump casing with suction and delivery connections with
the same diameter and on the same axis (in-line).
Stainless steel AISI 316 can.
Applications
Circulation of sanitary hot water.
Operating conditions
Liquid temperature from +5 °C to +65 °C.
Ambient temperature up to 40 °C.
Sound pressure ≤ 43 dB (A).
Minimum suction pressure: 0,05 bar at 50 °C
Maximum permissible working pressure 10 bar.
Designation
NCS3 2 0 - 4 0 / 1 3 0
Motor
Series 2-pole induction motor, 50 Hz.
Three adjustable speeds.
DN ports in mm NCS3: single-phase 230 V.
Max. head in dm Insulation class H.
Protection IP 44.
connection size mm
Coverage chart
6 NCS3
NCS
5 3 ..-7
0
NCS
3 ..-5
4 0
NCS
H 3 ..-4
0
m
0
0 Q m3/h 1 2 3 4
490
NCS3 Circulating pumps for sanitary hot water
Characteristic curves
6 6
4 4
3
3 3
3
Hm Hm
2 2
2 2
1 1
1 1
0 0
0 3 1 1.5 2 2.5 3 3.5 0 3 1 1.5 2 2.5 3 3.5
Q m /h Q m /h
0 l/min 10 20 30 40 50 0 l/min 10 20 30 40 50
0 l/s 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 0 l/s 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9
80 100
3
3
60 80
2
PW PW 2
40 1 60
1
20 40
0 20
0 Q m3/h 1 1.5 2 2.5 3 3.5 0 Q m3/h 1 1.5 2 2.5 3 3.5
7 8
6
5 3
3
5
4
2 2
Hm 4
3 Hm
3
1
2 1
2
1 1
0 0
0 3 1 1.5 2 2.5 3 3.5 4 0 3 2 3 4 5 6 7 8
Q m /h Q m /h
0 l/min 10 20 30 40 50 60 0 l/min 20 40 60 80 100 120
0 l/s 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1 1.1 0 l/s 0.4 0.6 0.8 1 1.2 1.4 1.6 1.8 2 2.2
160 200
3 3 2
120 150
2
PW 1 PW 1
80 100
40 50
0 0
0 Q m3/h 1 1.5 2 2.5 3 3.5 4 0 Q m3/h 2 3 4 5 6 7 8
491
NCS3 Circulating pumps for sanitary hot water
Examples of installations
DN 128
21
DN 107
80 49 Unions (on request)
1x
TYPE P1 230 V a Bocchettoni
DN Pos. (W) [A] mm [kg]
Unions
NCS3 20-40/130 G 1 1/4 3 70 0,30 DN
Rohrverschraubung
2 59 0,26 130 2,3
NCS3 25-40/130 G 1 1/2 1 41 0,18 Manchons
DN1
Uniones
NCS3 20-50/130 G 1 1/4 3 91 0,38
2 65 0,28 130 2,5
NCS3 25-50/130 G 1 1/2 1 42 0,18 TIPO -TYPE
TYPE - TYP DN DN1
NCS3 20-70/130 G 1 1/4 3 148 0,66 KIT G 1 1/4 - G 3/4 (NCS3 20..) G 1 1/4 G 3/4
2 128 0,59 130 3,8 KIT G 1 1/2 - G 1 (NCS3 25..) G 1 1/2 G1
NCS3 25-70/130 G 1 1/2 87 0,41
1
492
NC3 Three speeds circulating pumps
with threaded ports
Construction Installation
Pump casing with suction and delivery connections with the same
diameter and on the same axis (in-line).
Brass or cast iron unions on request.
Component Materials
Pump casing Cast iron
Impeller Composite
Shaft Stainless steel AISI 420
Applications
For clean liquids, without abrasives, which are non-aggressive for the
pump materials. Unions
Bocchettoni
Civil and industrial heaty sistems.
Unions
DN
Rohrverschraubung
Operating conditions
Liquid temperature from +5 °C to +110 °C (from -10 °C to +110 °C Manchons
for NC3 ..-70 and NC3 ..-80-85-120). DN1
Uniones
Ambient temperature up to 40 °C.
Sound pressure ≤ 43 dB (A).
Maximum glycol quantity: 50% (Mixture with more than 20% glycol TIPO - TYPE
TYPE - TYP DN DN1
content require recheking of the pumping data).
KIT G 1 - G 1/2 (NC3 15..) G1 G 1/2
Maximum permissible working pressure 10 bar.
KIT G 1 1/2 - G 1 (NC3 25..) G 1 1/2 G1
Minimum suction pressure: bar KIT G 2 - G 1 1/4 (NC3 32..) G2 G 1 1/4
TYPE Temperature
50 °C 80 °C 110 °C
NC3 ..-40,50,60 0,05 0,4 1,1
NC3 ..-70 0,05 0,4 1,1
NC3 ..-80,85,120 0,05 0,4 1,2
Designation NC3 32 - 70 / 180
Motor Series
2-pole induction motor, 50 Hz. DN ports in mm
Three adjustable speeds. Max. head in dm
NC3: single-phase 230 V. connection size mm
Insulation class H.
Protection IP 44.
493
NC3 Three speeds circulating pumps
with threaded ports
6 6
4 4
3 3
Hm 3 Hm
2
2 2 2
1
1 1 1
0 0
0 1 1.5 2 2.5 3 3.5 0 3 1 1.5 2 2.5 3 3.5
Q m /h Q m /h
3
0 l/min 10 20 30 40 50 0 l/min 10 20 30 40 50
0 l/s 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 0 l/s 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9
60 100
3 3
50 80
PW PW 2
2
40 60
1
1
30 40
20 20
0 Q m3/h 1 1.5 2 2.5 3 3.5 0 Q m3/h 1 1.5 2 2.5 3 3.5
DN fM
6
h1
NC3 ...-60
5
4
a
3
Hm
2
2 DN
107
80 49
1
1 1x mm
TYPE P1 230 V
DN Pos. (W) [A] a fM h1 [kg]
0
0 3 1 1.5 2 2.5 3 3.5 NC3 15-40/130 G 1 3 53 0,23 130 128 21 2,2
Q m /h
0 l/min 10 20 30 40 50 NC3 25-40/130 G 1 1/2 2 47 0,21 130 135 28 2,4
0 l/s 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 NC3 25-40/180 G 1 1/2 1 38 0,17 180 135 28 2,6
100
3
NC3 15-50/130 G 1 130 128 21 2,2
3 91 0,38
80 NC3 25-50/130 G 1 1/2 65 0,28
130 135 28 2,4
2
PW
2 NC3 25-50/180 G 1 1/2 1 42 0,18 180 135 28 2,6
60 NC3 32-50/180 G 2 180 138 31 3
1 NC3 15-60/130 G 1 130 128 21 2,2
3 95 0,41
40 NC3 25-60/130 G 1 1/2 70 0,30
130 135 28 2,4
2
NC3 25-60/180 G 1 1/2 1 44 0,20 180 135 28 2,6
20
0 Q m3/h 1 1.5 2 2.5 3 3.5
NC3 32-60/180 G 2 180 138 31 3
494
NC3 Three speeds circulating pumps
with threaded ports
8 8
7
NC3 ...-70 7 NC3 ...-80
3 2
1
1
0 1 2 3 4 5
40
3
3
2
2
1
1
0 1 2 3 4 5
DN B
C
180
DN
80 D
1x [mm]
TYPE P1 230 V
DN Pos. (W) [A] B C D [kg]
3 136 0,61
G
NC3 25-70/180 2 116 0,54 135 107 49 2,9
1 1/2 1 77 0,37
3 136 0,61
NC3 32-70/180 G2 2 116 0,54 138 107 49 3,1
1 77 0,37
3 206 0,91
NC3 32-80/180 G2 2 185 0,88 185 143 58 4,7
1 120 0,60
495
NC3 Three speeds circulating pumps
with threaded ports
2 3
8
1
1
40 40
3
2
3 1
2
DN B
C
180
DN
80 D
1x [mm]
TYPE P1 230 V
DN Pos. (W) [A] B C D [kg]
3 277 1,2
NC3 32-85/180 G2 2 250 1,16 185 143 58 4,9
1 172 0,85
3 265 1,15
NC3 32-120/180 G 2 2 251 1,14 208 174 68 5,2
1 176 0,85
496
03/2021
Construction
Regulation device for pump control equipped with flow and pres-
sure sensor connected to an electronic system.
Inlet and delivery connection ports of the same diameter.
Built-in check valve.
Pressure gauge 0-12 bar supplied as standard for IDROMAT 5..
(IDROMAT 6.. not present).
Automatic reset function for the reset of the system without
manual operation.
Applications
Automatic control of pumps for water supply and increase of
network pressure.
Control of starting/stopping of the pump when cocks are
opened/closed.
Operating conditions
Mains voltage: single-phase 230 V ±10% Idromat 5e;
single-phase 115 - 240 V ±5% for Idromat 5, 6.
Frequency: 50 - 60 Hz.
Current values:
- 8A max during operation (16A max at start-up) for IDROMAT 5;
- 16A max during operation (30A max at start-up) for IDROMAT 6
Maximum pump motor power 1,5 kW (2,2 kW for IDROMAT 6).
Protection: IP 65.
Operating conditions Maximum working pressure: 12 bar (1,2 MPa)
Maximum Operating temperature up to 65 °C.
Switching-on Pump Minimum flow ~ 1 l/min.
TYPE pressure head Male connections 1” (1 1/4 for IDROMAT 6).
IDROMAT 5-12 1,2 bar > 25 m
IDROMAT 5-15 1,5 bar > 30 m Materials
IDROMAT 5-22 2,2 bar > 35 m
IDROMAT 5-30 3 bar > 45 m Component Material
IDROMAT 6-15 1,5 bar > 30 m Housing Polyamide PA 6 G.F. reinforced
IDROMAT 6-30 3 bar > 45 m
Membrane Natural rubber
IDROMAT 5e adjustable from 1,5 to 2,5 bar (1)
H 1”
ΔH
m
Pump outlet head
A B 20
1” 1/4
10
Time
4.93.054
0
0 Q m3/h 2 4 6 8 10 12
497
IDROMAT Electronic regulator for pumps
Control Panel
IDROMAT 5 190
R1” 88 52
150,5
98
R1” 140
IDROMAT 6 251
Made in Italy
110V÷240V 65 °C max
50/60 Hz IP 65
30 (16) A max 12 bar max
P607.b- REV00
P607.a - REV00
R 1" 1/4
498
IDROMAT 5-12: max 12 m
IDROMAT 5-15: max 15 m
IDROMAT 5-22: max 22 m
IDROMAT 5-30: max 30 m
Foot valve
4.93.096
499
Electronic regulator for pumps
Check valve
IDROMAT 5-12: max 12 m
IDROMAT 5-15: max 15 m
IDROMAT 5-22: max 22 m
IDROMAT 5-30: max 30 m
Features
Flexibility
The standard double supply voltage (only for Idromat 5 and 6) allows to connect
power supply of 115 - 240V without modifications on the device.
Easy to use
With the Idromat 5e it is possible to change the re-start pressure, the operation is
possible also with the pump that operate.
Safety
The device includes a automatic re-start system with anti-lock mode in order to
reduce the user operations.
Reliability
The pressure gauge locking system (patented) allows an easy replacement in
case of failure and an easy drainage of the device.
User friendly
The high luminosity leds allows a higher visibility of the operating conditions.
500
03/2021
Construction
PATENTED Variable speed system driven by frequency converter, for the
pressure control in domestic and residential plants.
The system is connected to the delivery pipe providing for simple
installation and better cooling (patented) making the unit more
compact and easy to assemble.
Easymat is supplied with one pressure transducer, G 1/4
connection and 1.5 m cable length.
Applications
Automatic frequency inverter control for use on pumps to
increase network pressure.
The system maintains constant pressure whilst the controlling
the pump operation against changing system demand.
For protection of the pumps:
– Against dry running
– Against operations with closed connection ports
– Against overcurrent of the motor
– Against overvoltage and undervoltage of the power supply
Operating conditions
EASYMAT MM - Input voltage: 1~ 230V ±10%
- Output voltage: 1~ 230V
EASYMAT MT - Input voltage: 1~ 230V ±10%
- Output voltage: 3~ 230V
Input frequency: 50-60 Hz
Output frequency: up to 70 Hz
Protection: IP 55
Max Ambient temperature: 40°C
Features Max liquid temperature: 40 °C
Minimum Flow: 3 l/min
Constant pressure Altitude: no higher than 1000 m, inside a closed environment.
The Easymat via a frequency inverter keeps the pressure constant as the flow
demand changes.
Construction
(Standard execution)
Energy saving The system comprises of:
The variable speed operation ensures that only the energy required by the plant at - Frequency converter.
any instant is used. - Pressure transducer.
- Pipe housing.
- Fixing screws.
- Terminal board.
System reliability - Cable glands.
Because the easymat is independent of the pumped liquid it's operation is not - Multi-hole gaskets.
affected by fluid impurity.
A float switch can also be integrated to further protect against dry running.
Type
Type Freqeuency converter Standard power
Flexibility (single-phase) max motor
Thanks to it's patented design the easymat does not come into contact with the current output 230V
pumped fluid. This provides for more flexibility during installation eliminating the
need for pipe-work modifications or the installation of isolating valves. A kW
Easymat 9,2MM 9,2 0,37 - 1,5
Easy to use
The easymat has a clear display making it very simple to set-up. Type Freqeuency converter Standard power
(three-phase) max motor
current output 230V
501
Variable speed system driven
EASYMAT by frequency converter
Control Panel
Easymat is equipped with a control panel for simple system programming and
parameter monitoring.
The 2 scroll buttons are used to scroll the different operating parameters that
EASYMAT can show.
At the same time you can use the 2 scroll buttons to move in the set up menu and to
change the different options.
The LCD custom display gives an easy overview of the system situation and of the
operating parameters.
The icons on the top and below the display area explain in which way EASYMAT is
working and if there are problems on the system.
The four set-up buttons allow the operator to move between and set-up the menu's
and to start and stop the pump. The symbols help to make the function of each
P460
button clear.
With these 4 buttons and the 2 scroll buttons you can manage all the set-up and
operating parameters without the use of an other control panel or computer.
4.93.410
Display LCD
The integrated LCD custom display DISPLAY AREA
gives you an easy overview of the The display area gives the status of the
system situation and operating para- parameters of the pump.
meters.
Manual Mode
The icon show that the system is operating in manual mode (fixed speed mode), with the navigation buttons the user can change the speed,
the fixed speed mode is indicated by the icon on the lower part of the display.
Set-up Mode
The icon shows that the set-up menu is activated, in this mode it is possible to change all the operating parameters of the EASYMAT.
With the navigations buttons it is possible to scroll the parameters and, if necessary, change them.
Sensor State
indicates the state of the pressure transducer connected to the EASYMAT, if lit it indicates that the pressure transducer is working, if it is
blinking there is a fault or a incorrect connection of the pressure transducer.
Alarm
It indicates that there is a fault on the system, the error number appears on the display area.
Cascade Mode
It indicates that the multi-pump mode (up to 2 pumps) is working, the upper icon shows if the pump connected with the frequency
converter is running or is in stand-by, the lower icon indicates if the pump is the master pump (the icon is lit) or the slave pump (the icon is
blinking).
502
Variable speed system driven
EASYMAT by frequency converter
Overview
G 1 and G 1 1/4 aluminium
pipe housing (on request
G 1 1/2).
made in italy
190
503
Variable speed system driven
EASYMAT by frequency converter
Installation example
4.93.412 2.91.092
.4 _1
4.93.412.6
.2
4.93.412 Variable speed system version
.3
4.93.412
504
03/2021
Construction
Variable speed system driven by frequency converter for the
motor control in the water supply applications and in the produc-
tion/distribution of hot/cold water.
I-MAT is an integrated control system which, applied to the motor,
allows to manage a wide range of applications and operating
modes.
Classification scheme IE2 in accordance with EN 50598.2
Applications
Frequency converter for automatic pump control suitable for:
- water supply
- water transport and distribution
- production and distribution of hot/cold water
- water treatment
Operating conditions
Standard voltage: 400 V ±10% (380-415V) three-phase
Input voltage: 3~380V-10% ÷ 3~480V+5%
Output voltage: 0 ÷ 100% of the input voltage
Input frequency: 50-60 Hz
Output frequency: up to 70 Hz
Benefits Protection: IP55
Max Ambient Temperature: 50°C
Flexibility Altitude: no higher than 1000 m, inside closed environment.
I-MAT frequency converters are equipped with a software which provide different
operating modes in order to cover a wide range of applications.
Construction
(standard execution)
The system comprises of:
Reliability - Frequency converter
The high efficiency heatsink with integrated fans allows to cool the frequency - Removable control panel
converter independently from the motor, to provide a higher reliability of the - Power terminal board
system. - Signals terminal board
- Cable glands
On request:
Safety - Adapter for motor mounting
The shape of the I-MAT frequency converters allows to separate the signal - Adapter for wall mounting
terminals area, from the power terminals area, in this way the user can operate on - Pressure and temperature transducer
the signals connections in safety conditions. - Main switch
- Line filter and output filter
Easy to use
The integrated control panel allows to program all the parameters directly on the Type
frequency converters. Moreover it’s possible to remove the control panel and
remote it with a connection cable. Type Freqeuency converter Standard power
(three-phase) max motor
current output 400V
505
I-MAT Variable speed system driven
by frequency converter
Operating modes
Constant pressure mode
Constant pressure keeps the pressure constant at a fixed value set by the user. This value of pressure is automatically kept by the system
to provide to the final user a constant pressure even with different water demand, within the maximum performance of the motor-pump
system.
Night mode
The night mode is an optional mode which allows to reduce the speed of the pump if the temperature in the system decreases below a set
value, this operating mode can be used with all operating modes over described.
Control Panel
I-MAT is equipped with a control panel that allows to carry out the set-up of the
system and to monitor all system parameters.
The control panel is inside a IP55 enclosure which is possible to rotate and install
in remote positions.
It is possible use the control panel in remote positions by means a cable with M12
connectors (standard cable).
The LCD custom display gives an easy overview of the system situation and of
the operating parameters.
The icons on the top and below the display area explain in which way i-MAT is
working and if there are some problems on the system.
The 2 scroll buttons are used to scroll the different operating parameters that i-
MAT can show. At the same time you can use the 2 scroll buttons to move in the
set up menu and to change the different options.
The 4 set-up buttons are created to enter and to move on the set-up menus and
to start and to stop the pump. The symbols help to understand the function of
each button. With these 4 buttons and the 2 scroll buttons you can manage all the
set-up and operating parameters without the use of another control panel or
computers.
506
I-MAT Variable speed system driven
by frequency converter
Overview
Control panel
The integrated control panel gives the customer the
possibility to set all the parameters of the frequency Optional modules
converter. On the front side of the frequency converter are
predisposed compartments for connecting the
optional modules.
Main switch
The frequency converters have the possibi-
lity (optional) to install a main switch.
h l2
mm
TYPE
f
kg
h f l1 l2
I-MAT 5,2 TT-A 165 263 170 190 5,8
I-MAT 11,2 TT-B 165 292 185 210 6,7
I-MAT 25,8 TT-C 207 336 255 281 13,5
I-MAT 65,4 TT-D 288 460 320 350 33
l1 I-MAT 119 TT-E 336 700 424 455 59
507
I-MAT Variable speed system driven
by frequency converter
Installation example
One pump installation scheme
MXH EI NM EI NR EI MXV EI
508
03/2021
BS
Fixed speed pump units
Variable speed pump units with frequency converter
509
Index
Pressure boosting sets with NM,NMD pag. 518
Designation
BS M 2V 2 MXV 25/204 - I TT
BS M 1V 1F 2 MXV 25/204 - E MM
BS M 2F 2 MXV 25/204
T Three-phase motor
M Sigle-phase motor
Pump type
T Three-phase supply
Nr of pumps
M Sigle-phase supply
E= EASYMAT series,
I= I-MAT series
1F 1 fixed speed pump
2F 2 fixed speed pumps
3F 3 fixed speed pumps
1V1F 1 variable speed pump and 1 fixed speed pump
1V2F 1 variable speed pump and 2 fixed speed pumps
1V 1 variable speed pump
2V 2 variable speed pumps
3V 3 variable speed pumps
Sigle-phase supply
(no indication: three-phase supply)
Product series
511
Operation
BSF
with 2 and 3 fixed speed pumps
Construction
Pressure boosting sets with automatic operation, consisting in 2 and 3
pumps on a common baseplate, with sunction and delivery manifolds, gate
and non-return valves, pressure switches, pressure gauge, control panel
and from 100 to 1000 litres diaphragm tank (on request).
BS
BS 2F2F
2 fixed speed
2 pompe pumps fissa
a velocità
F F
BS
BS3F
3F
33 fixed
pompespeed pumpsfissa
a velocità
F F F
Operation
The control panel, with electronic card, manages the pump operation, the
changeover of pump starting sequence and it stops the system when there
is no air in the tank (patented system).
Pumps starting in a cascade sequence, with a signal from the pressure
switches.
BS
BS2F2F
2 fixed speed
2 pompe a pumps
velocità fissa
H
m
Stop
Start
Q m 3/h
BS
BS3F3F
3 fixed speed
3 pompe a pumps
velocità fissa
H
m
Stop
Start
Q m 3/h
512
BSV.F. BSV
2-6 variable speed pumps (with frequency converter)
1 variable speed pump (with frequency converter)
1 to 5 fixed speed pumps Construction
Construction Pressure boosting sets with automatic operation, consisting of
Pressure boosting sets with automatic operation, consisting of 1 variable variable speed pumps (from 1 to 6) with frequency converter,
speed pump with frequency converter and from 1 to 5 fixed speed pumps, assembled on a common baseplate, with suction and delivery
assembled on a common baseplate, with suction and delivery manifolds, manifolds, gate and non-return valves, pressure transducer,
gate and non-return valves, pressure gauge, control panel and 20 litres
diaphragm tank (on request).
pressure gauge, control panel and 20 litres diaphragm tank (on
request).
BS
BS1V1F
1V1F BS
BS2V
2V
22pumps:
pompe:1variable
1 variabile 22variable
pompespeed pumpsvariabile
a velocità
1 fixed
1 fissa
V F V V
BS
BS1V2F
1V2F BS
BS3V
3V
32pumps:
pompe:1variable
1 variabile 33variable
pompespeed pumpsvariabile
a velocità
2 fixed
2 fisse
V F F V V V
Operation Operation
The control panel, with electronic card, manages the pump operation, the
changeover of fixed speed pumps starting sequence The control panel, with electronic card, manages the pump ope-
Pumps starting is in a cascade sequence, with a signal from the pressu- ration, the changeover of pumps starting sequence.
re transducer. Pumps starting in a cascade sequence, with a signal from the
Constant pressure is guaranteed by the variable speed pumps, while pressure transducer.
fixed speed pumps start when the request is higher than the capacity of
the variable speed pump.
BSBS
1V1F
1V1F BS
BS2V2V
2 pumps: 1variable
2 pompe: 1 variabile 22variable
pompe speed pumps variabile
a velocità
1 fixed1 fissa
H H
m m
H set H set
Q m 3/h Q m 3/h
BSBS
1V2F
1V2F BS
BS3V3V
3 pumps: 1variable
3 pompe: 1 variabile 33variable
pompe speed pumps
a velocità variabile
2 fixed 2 fisse
H H
m m
H set H set
Q m 3/h Q m 3/h
513
Pressure Boosting Sets
Fixed speed pump units
New electrical control panels
for fixed speed pump units.
New electrical control panels for pressurisation units, all with
electronic card with microprocessors, for managing pump
operation.
In particular:
- pumps starting in a cascade sequence according to water
demand.
- changeover of pump starting sequence.
- delay start-up of the 2nd/3rd pump in case of breakdown of
pressure switch 1 or after a power cut.
- avoid pump starting in case of water hammering.
- activate the alarm when pressure 1 fails.
- activate the alarm when air cushion in the vessel drops.
- stop the pump when air cushion is over.
Operation
For booster sets made up to three pumps: according to the pressure decrease in the system, the pressure switches (pressure transducer for 3-pump
sets) make the pumps to start in cascade mode and the starting changeover is made by the
microprocessor.
For sets made of 4, 5, 6 pumps: Operation controlled by a microprocessor with signal from a pressure transducer. The pumps operate with only one
pressure setting.
514
Pressure Boosting Sets
Variable speed pump units with frequency converter
Silent operation
Motors working at reduced speed and check valves that close gradually mean that operation is particularly quite.
Energy savings
The motors consume only the precise level of power necessary moment to moment, in order to supply the quantity of water required by the system.
Great versatility
The great versatility of the MPS 4000 electronic card enables the construction of special units with operational logics different from those of normal pres-
surisation units, depending on the requirements and characteristics of the systems.
Operation
Depending on water consumption, one or more pumps are activated, all at variable speed, in order to guarantee the quantity of water required at the set
pressure.
515
Pressure Boosting Sets
Variable speed pump units with EASYMAT
EASYMAT
for variable speed pump units.
Variable speed system driven by frequency converter, for the pres-
sure control in domestic and residential plants.
The system maintains constant pressure whilst the controlling the
pump operation against changing system demand.
At the same time you can use the 2 scroll buttons to move in the
set up menu and to change the different options.
The icons on the top and below the display area explain in which
way EASYMAT is working and if there are problems on the
system.
The four set-up buttons allow the operator to move between and
set-up the menu's and to start and stop the pump. The symbols
help to make the function of each button clear.
With these 4 buttons and the 2 scroll buttons you can manage
all the set-up and operating parameters without the use of an
other control panel or computer
Operation
Depending on water consumption, one or more pumps are activated, all at variable speed, in order to guarantee the quantity of water required at the
set pressure.
The system is connected to the delivery pipe providing for simple installation and better cooling (patented) making the unit more compact and easy
to assemble.
Easymat is supplied with one pressure transducer, G 1/4 connection and 1.5 m cable length.
Silent operation
Motors working at reduced speed and check valves that close gradually mean that operation is particularly quite.
Energy savings
The motors consume only the precise level of power necessary moment to moment, in order to supply the quantity of water required by the system.
516
Pressure Boosting Sets
Variable speed pump units with I-MAT
I-MAT
for variable speed pump units.
Variable speed system driven by frequency converter, for the pres-
sure control in domestic and residential plants.
The system maintains constant pressure whilst the controlling the
pump operation against changing system demand.
The icons on the top and below the display area explain in which
way I-MAT is working and if there are some problems on the
system.
The 2 scroll buttons are used to scroll the different operating
parameters that I-MAT can show. At the same time you can use
the 2 scroll buttons to move in the set up menu and to change
the different options.
Operation
Depending on water consumption, one or more pumps are activated, all at variable speed, in order to guarantee the quantity of water required at the
set pressure.
Night mode
The night mode is an optional mode which allows to reduce the speed of the pump if the temperature in the system decreases below a set
value, this operating mode can be used with all operating modes over described.
Silent operation
Motors working at reduced speed and check valves that close gradually mean that operation is particularly quite.
Energy savings
The motors consume only the precise level of power necessary moment to moment, in order to supply the quantity of water required by the system.
517
BS. NM Pressure boosting sets with 1 to 3 Centrifugal Pumps
Fixed speed pump or Variable speed pump (frequency converter)
Coverage chart
50 100 U.S. g.p.m. 300 500 1000 2000
50 100 Imp. g.p.m. 300 500 1000 2000
120
100
90 300
80 H
m
H
m
1-3NM-NMD 200
60
50
40
30 100
90
80
70
20
10 m3/h 20 30 40 50 100 200 400 600
Q l/min
200 500 1000 2000 3000 5000 10000
72.961.C
Operation
BS 1-6F Pressure boosting sets with 1 to 6 fixed speed pump. Suction and delivery manifolds for boosting sets with 2,3 pumps:
- stainless steel AISI 304 up to 2NM 40.. and 3NM 32...
Sets with 4,5 and 6 pumps on request.
- steel S235JR from 2NM 50.. and 3NM 40... .
Depending on the reduction of the pressure in the system,
the pressure switches (pressure transducer for 3-pump sets)
Connections are located on the delivery manifold for the installation of
determine the starting up of the pumps in sequence and the
vessels G1 connection.
microprocessor alternates the starts.
Electrical control boards:
- with microprocessor for fixed speed pump units. Motor starting is D.O.L.
BS2-3V Pressure boosting sets with 2 to 3 variable speed pumps
up to 5,5 kW and Y/Δ for power rating 7,5 up to 55 kW.
(with I-MAT). - with frequency converter for variable speed pump units.
Depending on water consumption, one or more pumps are
activated, all at variable speed, in order to guarantee the The unit includes one pressure gauge and three adjustable differential
quantity of water required at the set pressure. pressure switches or pressure transducer.
BS1V2-5F Pressure boosting sets with 1 variable speed pump (with Applications
frequency converter into the control panel) and from 1 to 5 To supply water in civil and industrial buildings.
fixed speed pumps As pressure boosting pump to increase water pressure when needed
Sets with 4,5 and 6 pumps on request. (follow local rules).
According to the water consumption, one or more pumps
start, one at variable speed and the others at fixed speed,
to grant the water quantity required at the set pressure. Motors
2-pole induction motors, 50 Hz, n ≈ 2900 rpm, suitable for operation with
frequency converter.
- Three-phase 230/400V ± 10% up to 3 kW;
BS1-6V Pressure boosting sets with 1 to 6 variable speed pumps 400/690V ± 10% for 4 kW to 55 kW;
Insulation class F.
(with frequency converter into the control panel).
Protection IP 54.
Sets with 4,5 and 6 pumps on request.
Constructed in accordance with: IEC 60034.
Depending on water consumption, one or more pumps are
Other voltages and frequencies on request.
activated, all at variable speed, in order to guarantee the
quantity of water required at the set pressure.
Vessels on request
When installing the unit, connect in the delivery section to a diaphragm
or galvanised tank.
The recommended sized are shown in the following page.
Construction
- Automatic pressure boosting plant consisting of 1 to 6 centrifugal pumps
complete with ball, non return valve on the suction side and ball valves
Special features on request
Pressure boosting sets with 4,5 and 6 pumps.
on the delivery side.
518
BS. NM Pressure boosting sets with 1 to 3 Centrifugal Pumps
Fixed speed pump or Variable speed pump (frequency converter)
Coverage chart
36 34
1-3NM 2/A 32 1-3NMD 20/110B
34
30
32
28
30 26
H m
H m
28 24
22
26
20
24
18
22 16
0 5 10 15 20 0 2 4 6 8 10 12
Q m 3/h Q m 3/h
46 54
1-3NMD 20/110A 52 1-3NMD 20/140B
42
50
38
48
34 46
H m
H m
1~ 1~ 1~
44
30
42 3~ 3~ 3~
26
40
22 38
0 Q m 3/h
2 4 6 8 10 12 14 0 Q m 3/h 4 8 12 16
70 65
3~
65
1-3NMD 20/140A 1-3NMD 25/190C
60
60 1~
55
55
50
H m
H m
50
45
45
40 40
35 35
0 4 8 12 16 20 0 5 10 15 20 25 30
Q m 3/h Q m 3/h
80 100
1-3NMD 25/190B 1-3NMD 25/190A
75 95
70
90
65
85
H m
H m
60
80
55
50 75
45 70
0 3 5 10 15 20 25 30 0 5 10 15 20 25 30
Q m /h Q m 3/h
519
BS. NM Pressure boosting sets with 1 to 3 Centrifugal Pumps
Fixed speed pump or Variable speed pump (frequency converter)
Coverage chart
40 50
1-3NM 3/C/A 1-3NM 3/B/A
38 45
36
40
34
H m
H m
35
32
30
30
28 25
0 Q m 3/h 5 10 15 20 0 6 8 10 12 14 16 18 20 22 24 26
Q m 3/h
60 32
1-3NM 3/A/B 1-3NM 25/160B/A
55 30
50 28
H m
H m
45 26
40 24
35 22
0 Q m 3/h 6 8 10 12 14 16 18 20 22 24 26 0 Q m 3/h 5 10 15 20 25 30
40 44
1-3NM 25/160A/A 1-3NM 25/20B/C
42
35
40
H m
H m
38
30
36
25 34
0 Q m 3/h 10 20 30 40 0 Q m 3/h 10 20 30 40
52 60
1-3NM 25/20A/B 1-3NM 25/20S/C
50
48
55
46
H m
H m
44
50
42
40
38 45
0 10 20 30 40 50 0 10 20 30 40 50 60
Q m 3/h Q m 3/h
520
BS. NM Pressure boosting sets with 1 to 3 Centrifugal Pumps
Fixed speed pump or Variable speed pump (frequency converter)
Coverage chart
32 38
1-3NM 32/16BE 37 1-3NM 32/16A/A
30
36
28
35
26 34
H m
H m
33
24
32
22 31
20 30
0 Q m 3/h 10 20 30 40 50 0 10 20 30 40 50
Q m 3/h
48 60
1-3NM 32/20C/A 1-3NM 32/20A/A
46 58
44
56
42
54
H m
H m
40
52
38
36 50
34 48
0 Q m 3/h 10 20 30 40 50 0 Q m 3/h 10 20 30 40 50
32 42
H m
32
22
30
20
28
18 26
16 24
0 3
20 30 40 50 60 70 80 90 0 20 30 40 50 60 70 80 90 100
Q m /h Q m 3/h
56 64
1-3NM 32L/20B 60
1-3NM 32L/20A
52
56
48
52
44
H m
H m
48
40
44
36 40
32 36
0 Q m 3/h 20 30 40 50 60 70 80 90 0 Q m 3/h 20 30 40 50 60 70 80 90 100
521
BS. NM Pressure boosting sets with 1 to 3 Centrifugal Pumps
Fixed speed pump or Variable speed pump (frequency converter)
Coverage chart
80 90
1-3NMD 32/210D/A 1-3NMD 32/210C/A
70
80
60
70
H m
H m
50
60
40
30 50
0 Q m 3/h 10 20 30 40 0 Q m 3/h 10 20 30 40 50
110 120
1-3NMD 32/210B/A 1-3NMD 32/210A/B
100 110
90 100
H m
H m
80 90
70 80
0 Q m 3/h 10 20 30 40 50 0 Q m 3/h 10 20 30 40 50
65 75
60 1-3NMD 40/180D/A 70 1-3NMD 40/180C/A
55 65
50
60
45
55
H m
H m
40
50
35
30 45
25 40
20 35
0 Q m 3/h 20 40 60 80 0 Q m 3/h 20 40 60 80
90 100
1-3NMD 40/180B/A 1-3NMD 40/180A/B
85 95
80 90
75 85
H m
H m
70 80
65 75
60 70
55 65
0 Q m 3/h 20 40 60 80 0 Q m 3/h 20 40 60 80
522
BS. NM Pressure boosting sets with 1 to 3 Centrifugal Pumps
Fixed speed pump or Variable speed pump (frequency converter)
Coverage chart
26 32
24 1-3NM 40/16C/C 30 1-3NM 40/16B/B
28
22
26
20
24
18 22
H m
H m
16 20
18
14
16
12
14
10 12
8 10
0 Q m 3/h 30 40 50 60 70 80 90 100 110 120 0 Q m 3/h 40 60 80 100 120 140
40 45
1-3NM 40/16A/B 40
1-3NM 40/20D/A
35
35
30 30
H m
H m
25
25
20
20
15
15 10
0 Q m 3/h 50 100 150 0 Q m 3/h20 30 40 50 60 70 80 90 100 110 120
44 55
1-3NM 40/20C/A 1-3NM 40/20B/A
42
50
40
45
38
H m
H m
40
36
34 35
32 30
0 Q m
103/h 20 30 40 50 60 70 80 90 0 Q m 3/h20 40 60 80 100 120
56 60
55
1-3NM 40/20AR/A 1-3NM 40/20A/A
55
54
53
50
52
H m
H m
51 45
50
40
49
48 35
0 Q m 3/h 20 30 40 50 60 70 80 90 0 Q m 3/h 40 60 80 100 120 140
523
BS. NM Pressure boosting sets with 1 to 3 Centrifugal Pumps
Fixed speed pump or Variable speed pump (frequency converter)
Coverage chart
75 95
70
1-3NM 40/25B/C 1-3NM 40/25A/C
90
65
60 85
H m
H m
55
80
50
75
45
40 70
0 Q m 3/h 40 60 80 100 120 140 0 Q m 3/h 40 60 80 100 120 140
35 45
1-3NM 50/16B/B 1-3NM 50/16A/B
30 40
25 35
20 30
H m
H m
15 25
10 20
5 15
0 Q m 3/h 50 100 150 200 250 0 Q m 3/h 50 100 150 200 250
50 60
1-3NM 50/20B/C 1-3NM 50/20A/C
45 55
40 50
35 45
H m
H m
30 40
25 35
20 30
0 50 100 150 200 250 0 Q m 3/h 50 100 150 200 250
Q m 3/h
65
1-3NM 50/20S/C
60
55
50
H m
45
40
35
0 Q m 3/h 50 100 150 200 250
524
BS. NM Pressure boosting sets with 1 to 3 Centrifugal Pumps
Fixed speed pump or Variable speed pump (frequency converter)
Coverage chart
60 75
55 1-3NM 50/25C/C 1-3NM 50/25B/C
70
50
65
45
60
40
H m
H m
55
35
30 50
25 45
20 40
0 Q m 3/h 40 60 80 100 120 140 160 180 200 220 0 Q m 3/h 40 60 80 100 120 140 160 180 200 220
85 26
1-3NM 50/25A/D 1-3NM 65/16D
80 24
75
22
70
H m
H m
20
65
18
60
55 16
0 Q 20 0 100 200 300 400
m 3/h 40 60 80 100 120 140 160 180 200 220 Q m 3/h
30 34
28
1-3NM 65/16C 1-3NM 65/16B/C
32
26
30
24
28
H m
H m
22
26
20
18 24
16 22
0 100 200 300 400 0 100 200 300 400
Q m 3/h Q m 3/h
38 42
1-3NM 65/16AR 1-3NM 65/16A/C
36 40
34
38
32
H m
H m
36
30
34
28
26 32
0 Q m 3/h 100 200 300 400 0 Q m 3/h 100 200 300 400
525
BS. NM Pressure boosting sets with 1 to 3 Centrifugal Pumps
Fixed speed pump or Variable speed pump (frequency converter)
Coverage chart
46 52
1-3NM 65/20C/C 50 1-3NM 65/20B/D
42
48
38 46
44
H m
H m
34 42
40
30
38
26 36
0 Q m 3/h 100 150 200 250 300 350 400 450 Q m 3/h 100 150 200 250 300 350 400 450
60 64
H m
52
50 50
48 48
46
46
44
44 42
0 Q m 3/h 100 150 200 250 300 350 400 450 0 Q m 3/h 100 200 300 400
76 88
74 1-3NMS 65/250B/A 86
1-3NMS 65/250A/B
72
84
70
68 82
H m
H m
66 80
64
78
62
76
60
58 74
0 Q m 3/h 100 200 300 400 0 Q m 3/h 100 200 300 400
526
BS. NM Pressure boosting sets with 1 to 3 Centrifugal Pumps
Fixed speed pump or Variable speed pump (frequency converter)
Coverage chart
24 28
22
1-3NM 80/16E/B 26
1-3NM 80/16D/C
20 24
18 22
H m
H m
16 20
14 18
12 16
10 14
0 Q m 3/h 100 200 300 400 500 0 100 200 300 400 500
Q m 3/h
30 36
28
1-3NM 80/16C/C 34
1-3NM 80/16B/C
26 32
24 30
H m
H m
22 28
20 26
18 24
16 22
0 100 200 300 400 500 600 0 Q m 3/h100 200 300 400 500 600
Q m 3/h
42 48
1-3NM 80/16A/D 46 1-3NM 80/20B
40
44
38
42
36
40
H m
H m
34
38
32
36
30 34
28 32
0 Q m 3/h100 200 300 400 500 600 0 Q m 3/h
100 200 300 400 500 600
58 55
50 40
H m
H m
48
35
46
30
44
42 25
0 Q m 3/h100 200 300 400 500 600 0 Q m 3/h
100 200 300 400 500 600
527
BS. NM Pressure boosting sets with 1 to 3 Centrifugal Pumps
Fixed speed pump or Variable speed pump (frequency converter)
Coverage chart
70 80
1-3NMS 80/250D 1-3NMS 80/250C/A
65 75
60 70
55 65
H m
H m
50 60
45 55
40 50
0 Q m 3/h100 200 300 400 500 600 0 Q m 3/h
100 200 300 400 500 600
90 100
1-3NMS 80/250B/A 1-3NMS 80/250A/A
85 95
80
90
H m
75
H m
85
70
80
65
60 75
0 Q m 3/h100 200 300 400 500 600 0 Q m 3/h100 200 300 400 500 600
32 38
1-3NM 100/20E/A 36 1-3NM 100/20D
30
34
28 32
26 30
28
H m
H m
24
26
22 24
22
20
20
18 18
0 250 500 750 0 Q m 3/h150 300 450 600 750 900
Q m 3/h
528
BS. NM Pressure boosting sets with 1 Centrifugal Pumps
Fixed speed pump
Performance
BS1F
Mains: 400V 3~ Motor Pres. switch 1 Vessel Vessel
Motor: 400V 3~ bar Membrane
kW HP min max litre litre
BS1F 1NM 32/16B/A 1,5 2 2,2 2,8 500 800
BS1F 1NM 32/16A/B 2,2 3 2,7 3,4 500 1000
BS1F 1NM 32/20C/A 3 4 3,2 4,2 500 1000
BS1F 1NM 32/20A/B 4 5,5 4,5 5,5 750 1000
BS1F 1NM 32L/16B 3 4 1,9 2,7 750 1500
BS1F 1NM 32L/16A 4 5,5 2,8 3,6 1500 3000
BS1F 1NM 32L/20B 5,5 7,5 3,1 4,6 1000 1500
BS1F 1NM 32L/20A 7,5 10 3,7 5,3 1500 3000
BS1F 1NMD 32/210D/B 4 5,5 5 7 500 500
BS1F 1NMD 32/210C/A 5,5 7,5 6 8 500 800
BS1F 1NMD 32/210B/A 7,5 10 8 10 750 1000
BS1F 1NMD 32/210A/B 9,2 12,5 9,5 11 1000 1500
BS1F 1NMD 40/180D/B 4 5,5 4 5,5 500 1000
BS1F 1NMD 40/180C/A 5,5 7,5 5 6,5 750 1500
BS1F 1NMD 40/180B/A 7,5 10 6,7 8,2 1000 2000
BS1F 1NMD 40/180A/B 9,2 12,5 7,5 9 1500 2000
BS1F 1NM 40/16B/B 3 4 1,5 2,5 750 1500
BS1F 1NM 40/16A/C 4 5,5 2,4 3,4 1000 2000
BS1F 1NM 40/20B/A 5,5 7,5 3,7 4,7 1500 3000
BS1F 1NM 40/20A/A 7,5 10 4,4 5,4 2000 4000
BS1F 1NM 40/25B/C 11 15 5,6 6,6 3000 5000
BS1F 1NM 40/25A/C 15 20 7,7 8,7 4000 -
BS1F 1NM 50/16B/B 5,5 7,5 1,7 2,7 2000 4000
BS1F 1NM 50/16A/B 7,5 10 2,5 3,5 3000 5000
BS1F 1NM 50/20B/C 9,2 12,5 3,5 4,5 3000 5000
BS1F 1NM 50/20A/C 11 15 4,2 5,2 4000 -
BS1F 1NM 50/25C/C 11 15 4,1 5,1 4000 -
BS1F 1NM 50/25B/C 15 20 5,6 6,6 4000 -
BS1F 1NM 50/25A/D 18,5 25 6,6 7,6 5000 -
BS1F 1NM 65/16B/C 11 15 2,2 3,2 4000 -
BS1F 1NM 65/16AR 15 20 2,6 3,6 5000 -
BS1F 1NM 65/16A/C 15 20 3,1 4,1 5000 -
BS1F 1NM 65/20C/C 15 20 3 4 - -
BS1F 1NM 65/20B/D 18,5 25 3,6 4,6 - -
BS1F 1NM 65/20A/A 22 30 4,2 5,2 - -
BS1F 1NM 65/25C/A 22 30 5 6 - -
BS1F 1NMS 65/250B/A 30 40 6,6 7,6 - -
BS1F 1NMS 65/250A/A 37 50 7,7 8,7 - -
BS1F 1NM 80/16B/C 15 20 2,5 3,5 - -
BS1F 1NM 80/16A/D 18,5 25 2 3 - -
BS1F 1NM 80/20B 22 30 3,3 4,3 - -
BS1F 1NMS 80/200A 30 40 4,3 5,3 - -
BS1F 1NM 80/25E 22 30 3,8 4,8 - -
BS1F 1NMS 80/250D 30 40 4,5 6 - -
BS1F 1NMS 80/250C/A 37 50 5,5 7 - -
BS1F 1NMS 80/250B/A 45 60 6,5 8 - -
BS1F 1NMS 80/250A/A 55 75 8 9 -
529
BS. NM Pressure boosting sets with 2 Centrifugal Pumps
Fixed speed pump
Performance
BS2F
Mains: 400V 3~ Motor Pres. switch 1 Pres. switch 2 Vessel Vessel
Motor: 400V 3~ bar bar Membrane
kW HP min max min max litre litre
BS2F 2NMD 20/110B/A 0,45 x2 0,6 x2 2,0 3,0 1,7 2,7 24x2 100
BS2F 2NMD 20/110A/B 0,75 x2 1 x2 2,8 4,0 2,4 3,6 60 100
BS2F 2NM 2/A/B 0,75 x2 1 x2 2,0 3,0 1,7 2,7 80 200
BS2F 2NMD 20/140B/A 1,1 x2 1,5 x2 3,4 4,9 3,2 4,7 80 200
BSM2F 2NMDM 20/140AE 1,5 x2 2 x2 4,0 5,3 3,7 5,0 100 200
BS2F 2NMD 20/140A/A 1,5 x2 2 x2 5,0 6,3 4,7 6,0 100 200
BS2F 2NM 3/C/A 1,1 x2 1,5 x2 2,5 3,5 2,2 3,2 100 200
BSM2F 2NMM 3/BE 1,5 x2 2 x2 3,0 4,0 2,7 3,7 100 300
BS2F 2NM 3/B/A 1,5 x2 2 x2 3,2 4,5 2,9 4,2 100 300
BS2F 2NM 3/A/B 2,2 x2 3 x2 4,0 5,3 3,7 5,0 200 300
BS2F 2NM 25/20B/C 2,2 x2 3 x2 3,0 4,0 2,7 3,7 300 500
BS2F 2NM 25/20A/B 3 x2 4 x2 3,8 4,8 3,5 4,5 500 800
BS2F 2NM 25/20S/C 4 x2 5,5 x2 4,0 5,5 3,5 5,0 500 800
BS2F 2NMD 25/190C/B 2,2 x2 3 x2 4,3 5,8 3,8 5,3 200 300
BS2F 2NMD 25/190B/A 3 x2 4 x2 5,0 7,0 4,5 6,5 200 300
BS2F 2NMD 25/190A/B 4 x2 5,5 x2 7,5 9,0 7,0 8,5 300 500
BS2F 2NM 32/16B/A 1,5 x2 2 x2 2,2 2,8 2 2,6 500 800
BS2F 2NM 32/16A/B 2,2 x2 3 x2 2,7 3,4 2,5 3,2 500 1000
BS2F 2NM 32/20C/A 3 x2 4 x2 3,2 4,2 3 4 500 1000
BS2F 2NM 32/20A/B 4 x2 5,5 x2 4,5 5,5 4 5 750 1000
BS2F 2NM 32L/16B 3 x2 4 x2 1,9 2,7 1,6 2,4 750 1500
BS2F 2NM 32L/16A 4 x2 5,5 x2 2,8 3,6 2,5 3,3 1000 2000
BS2F 2NM 32L/20B 5,5 x2 7,5 x2 3,2 4,7 2,9 4,4 750 1000
BS2F 2NM 32L/20A 7,5 x2 10 x2 3,7 5,4 3,5 5,1 1000 1500
BS2F 2NMD 32/210D/B 4 x2 5,5 x2 5 7 4,5 6,5 500 500
BS2F 2NMD 32/210C/A 5,5 x2 7,5 x2 6 8 5,5 7,5 500 800
BS2F 2NMD 32/210B/A 7,5 x2 10 x2 8 10 7,5 9,5 750 1000
BS2F 2NMD 32/210A/B 9,2 x2 12,5 x2 9,5 11 9 10,5 1000 1500
BS2F 2NMD 40/180D/B 4 x2 5,5 x2 4 5,5 3,5 5 500 1000
BS2F 2NMD 40/180C/A 5,5 x2 7,5 x2 5 6,5 4,5 6 750 1500
BS2F 2NMD 40/180B/A 7,5 x2 10 x2 6,7 8,2 6,2 7,7 1000 2000
BS2F 2NMD 40/180A/B 9,2 x2 12,5 x2 7,5 9 7 8,5 1500 2000
BS2F 2NM 40/16B/B 3 x2 4 x2 1,5 2,5 1,2 2,2 750 1500
BS2F 2NM 40/16A/C 4 x2 5,5 x2 2,4 3,4 2 3 1000 2000
BS2F 2NM 40/20B/A 5,5 x2 7,5 x2 3,7 4,7 3,3 4,3 1500 3000
BS2F 2NM 40/20A/A 7,5 x2 10 x2 4,4 5,4 3,9 4,9 2000 4000
BS2F 2NM 40/25B/C 11 x2 15 x2 5,6 6,6 5,1 6,1 3000 5000
BS2F 2NM 40/25A/C 15 x2 20 x2 7,7 8,7 7,3 8,3 4000 -
BS2F 2NM 50/16B/B 5,5 x2 7,5 x2 1,7 2,7 1,2 2,2 2000 4000
BS2F 2NM 50/16A/B 7,5 x2 10 x2 2,5 3,5 2 3 3000 5000
BS2F 2NM 50/20B/C 9,2 x2 12,5 x2 3,5 4,5 3 4 3000 5000
BS2F 2NM 50/20A/C 11 x2 15 x2 4,2 5,2 3,7 4,7 4000 -
BS2F 2NM 50/25C/C 11 x2 15 x2 4,1 5,1 3,6 4,6 4000 -
BS2F 2NM 50/25B/C 15 x2 20 x2 5,6 6,6 5,1 6,1 4000 -
BS2F 2NM 50/25A/D 18,5 x2 25 x2 6,6 7,6 6,1 7,1 5000 -
BS2F 2NM 65/16B/C 11 x2 15 x2 2,2 3,2 1,7 2,7 4000 -
BS2F 2NM 65/16AR 15 x2 15 x2 2,6 3,6 2,1 3,1 5000
BS2F 2NM 65/16A/C 15 x2 15 x2 3,1 4,1 2,6 3,6 5000 --
BS2F 2NM 65/20C/C 15 x2 20 x2 3 4 2,5 3,5 - -
BS2F 2NM 65/20B/D 18,5 x2 25 x2 3,6 4,6 3,2 4,2 - -
BS2F 2NM 65/20A/A 22 x2 30 x2 4,2 5,2 3,8 4,8 - -
BS2F 2NM 65/25C/A 22 x2 30 x2 5 6 4,6 5,6 - -
BS2F 2NMS 65/250B/A 30 x2 40 x2 6,6 7,6 6,2 7,2 - -
BS2F 2NMS 65/250A/A 37 x2 50 x2 7,7 8,7 7,3 8,3 - -
BS2F 2NM 80/16B/C 15 x2 20 x2 2,2 3,2 1,7 2,7 - -
BS2F 2NM 80/16A/D 18,5 x2 25 x2 2,8 3,8 2,3 3,3 - -
BS2F 2NM 80/20B 22 x2 30 x2 3,3 4,3 3 4 - -
BS2F 2NMS 80/200A 30 x2 40 x2 4,3 5,3 4 5 - -
BS2F 2NM 80/25E 22 x2 30 x2 3,8 4,8 3,2 4,2 - -
BS2F 2NMS 80/250D 30 x2 40 x2 4,5 6 4 5,5 - -
BS2F 2NMS 80/250C/A 37 x2 50 x2 5,5 7 5 6,5 - -
BS2F 2NMS 80/250B/A 45 x2 60 x2 6,5 8 6 7,5 - -
BS2F 2NMS 80/250A/A 55 x2 75 x2 8 9 7,5 8,5 - -
530
BS. NM Pressure boosting sets with 3 Centrifugal Pumps
Fixed speed pump
Performance
BS3F
Mains: 400V 3~ Motor pressure transducer Vessel Vessel
Motor: 400V 3~ bar Membrane
kW HP min max litre litre
BS3F 3NM 40/16B/B 3 x3 4 x3 1,8 2,6 750 2000
BS3F 3NM 40/16A/C 4 x3 5,5 x3 2,5 3,3 1500 3000
BS3F 3NM 40/20B/A 5,5 x3 7,5 x3 3 4,5 1000 2000
BS3F 3NM 40/20A/A 7,5 x3 10 x3 3,5 5,1 1500 3000
BS3F 3NM 40/25B/C 11 x3 15 x3 4,5 6,2 2000 3000
BS3F 3NM 40/25A/C 15 x3 20 x3 6,1 8,1 3000 4000
BS3F 3NM 50/16B/B 5,5 x3 7,5 x3 2 2,8 2000 4000
BS3F 3NM 50/16A/B 7,5 x3 10 x3 2,6 3,4 3000 6000
BS3F 3NM 50/20B/C 9,2 x3 12,5 x3 3,4 4,3 - 6000
BS3F 3NM 50/20A/C 11 x3 15 x3 3,4 4,9 3000 5000
BS3F 3NM 50/25C/C 11 x3 15 x3 3,4 4,9 3000 5000
BS3F 3NM 50/25B/C 15 x3 20 x3 4,5 6,2 - 6000
BS3F 3NM 50/25A/D 18,5 x3 25 x3 5,4 7,2 - 8000
BS3F 3NM 65/16B/C 11 x3 15 x3 2,1 2,9 - 10000
BS3F 3NM 65/16AR 15 x3 20 x3 2,4 3,2 - -
BS3F 3NM 65/16A/C 15 x3 20 x3 2,8 3,6 - -
BS3F 3NM 65/20C/C 15 x3 20 x3 3 3,9 - -
BS3F 3NM 65/20B/D 18,5 x3 25 x3 2,9 4,4 - -
BS3F 3NM 65/20A/A 22 x3 30 x3 3,5 5 - -
BS3F 3NM 65/25C/A 22 x3 30 x3 4 5,7 - -
BS3F 3NMS 65/250B/A 30 x3 40 x3 5,3 7,1 - -
BS3F 3NMS 65/250A/A 37 x3 50 x3 6,1 8,1 - -
BS3F 3NM 80/16B/C 15 x3 20 x3 2,3 3,1 - -
BS3F 3NM 80/16A/C 18,5 x3 25 x3 2,7 3,5 - -
BS3F 3NM 80/20B 22 x3 30 x3 3,2 4,1 - -
BS3F 3NMS 80/200A 30 x3 40 x3 3,4 4,9 - -
BS3F 3NM 80/25E 22 x3 30 x3 3 4,5 -
BS3F 3NMS 80/250D 30 x3 40 x3 4,1 5,8 - -
BS3F 3NMS 80/250C/A 37 x3 50 x3 4,8 6,6 - -
BS3F 3NMS 80/250B/A 45 x3 60 x3 5,7 7,6 - -
BS3F 3NMS 80/250A/A 55 x3 75 x3 6,6 8,6 - -
531
BS. NM Pressure boosting sets with 1 to 3 Centrifugal Pumps
Fixed speed pump or Variable speed pump (frequency converter)
Performance
BS.. BS.. ..-ITT
PP22 PP22
N.PUMPS
POMPENos PUMPS Nos
N. POMPE
PUMP
TIPO TYPE
POMPE ForPer
eachpompa
pump PUMP TYPE
TIPO POMPE ForPer
eachpompa
pump
1 2 3 4 5 6 kW HP 2 3 kW HP
NM 2/A/B 0,75 1 NM 3/C/A-ITT 1,1 1,5
NMD 20/110B/A 0,45 0,6 NM 3/B/A-ITT 1,5 2
NMD 20/110A/B 0,75 1 NM 3/A/B-ITT 2,2 3
NMD 20/140B/A 1,1 1,5 NM 25/160B/A-ITT 1,1 1,5
NMD 20/140A/A 1,5 2 NM 25/160A/A-ITT 1,5 2
NM 3/C/A 1,1 1,5 NM 25/20B/C-ITT 2,2 3
BS2V NM 3/B/A 1,5 2 NM 25/20A/B-ITT 3 4
BS1V1F NM 3/A/B 2,2 3 NM 25/20S/C-ITT 4 5,5
NM 25/20B/C 2,2 3 NM 32/16B/A-ITT 1,5 2
NM 25/20A/B 3 4 NM 32/16A/B-ITT 2,2 3
NM 25/20S/C 4 5,5 NM 32/20D/B-ITT 2,2 3
NMD 25/190C/B 2,2 3 NM 32/20C/A-ITT 3 4
NMD 25/190B/A 3 4 NM 32/20A/B-ITT 4 5,5
NMD 25/190A/B 4 5,5 NM 32L/16B-ITT 3 4
NM 32/16B/A 1,5 2 NM 32L/16A-ITT 4 5,5
NM 32/16A/B 2,2 3 NM 32L/20B-ITT 5,5 7,5
NM 32/20C/A 3 4 NM 32L/20A-ITT 7,5 10
NM 32/20A/B 4 5,5 NM 40/16C/C-ITT 2,2 3
NM 32L/16B 3 4 NM 40/16B/B-ITT 3 4
NM 32L/16A 4 5,5 NM 40/16A/C-ITT 4 5,5
NM 32L/20B 5,5 7,5 NM 40/20D/B-ITT 4 5,5
NM 32L/20A 7,5 10 NM 40/20C/B-ITT 4 5,5
NMD 32/210D/B 4 5,5 NM 40/20B/A-ITT 5,5 7,5
NMD 32/210C/A 5,5 7,5 NM 40/20AR/A-ITT 5,5 7,5
NMD 32/210B/A 7,5 10 BS2V BS3V NM 40/20A/A-ITT 7,5 10
NMD 32/210A/B 9,2 12,5 -ITT -ITT NM 40/25C/C-ITT 9,2 12,5
NMD 40/180D/B 4 5,5 NM 40/25B/C-ITT 11 15
NMD 40/180C/A 5,5 7,5 NM 40/25A/C-ITT 15 20
NMD 40/180B/A 7,5 10 NM 50/16B/B-ITT 5,5 7,5
NMD 40/180A/B 9,2 12,5 NM 50/16A/B-ITT 7,5 10
NM 40/16B/B 3 4 NM 50/20B/C-ITT 9,2 12,5
NM 40/16A/C 4 5,5 NM 50/20A/C-ITT 11 15
NM 40/20B/A 5,5 7,5 NM 50/20S/C-ITT 15 20
NM 40/20A/A 7,5 10 NM 50/25C/C-ITT 11 15
NM 40/25B/C 11 15 NM 50/25B/C-ITT 15 20
BS1V BS2V BS3V BS4V BS5V BS6V NM 40/25A/C 15 20 NM 50/25A/D-ITT 18,5 25
BS1V1F BS1V2F BS1V3F BS1V4F BS1V5F NM 50/16B/B 5,5 7,5 NM 65/16D/B-ITT 7,5 10
NM 50/16A/B 7,5 10 NM 65/16C/C-ITT 9,2 12,5
NM 50/20B/C 9,2 12,5 NM 65/16B/C-ITT 11 15
NM 50/20A/C 11 15 NM 65/16AR-ITT 15 20
NM 50/25C/C 11 15 NM 65/16A/C-ITT 15 20
NM 50/25B/C 15 20 NM 65/20C/C-ITT 15 20
NM 50/25A/D 18,5 25 NM 65/20B/D-ITT 18,5 25
NM 65/16B/C 11 15 NM 65/20A/A-ITT 22 30
NM 65/16AR 15 20 NM 65/25C/A-ITT 22 30
NM 65/16A/C 15 20 NM 80/16E/B-ITT 7,5 10
NM 65/20C/C 15 20 NM 80/16D/C-ITT 9,2 12,5
NM 65/20B/D 18,5 25 NM 80/16C/C-ITT 11 15
NM 65/20A/A 22 30 NM 80/16B/C-ITT 15 20
NM 65/25C/A 22 30 NM 80/16A/D-ITT 18,5 25
NMS 65/250B/A 30 40 NM 80/20B-ITT 22 30
NMS 65/250A/A 37 50 NM 80/25E-ITT 22 30
NM 80/16B/C 15 20 NM 100/20E/A-ITT 18,5 25
NM 80/16A/D 18,5 25 NM 100/20D-ITT 22 30
NM 80/20B 22 30
NMS 80/200A 30 40
NM 80/25E 22 30
NMS 80/250D 30 40
NMS 80/250C/A 37 50
NMS 80/250B/A 45 60
NMS 80/250A /A 55 75
532
BS. NM Pressure boosting sets with 1 to 3 Centrifugal Pumps
Fixed speed pump or Variable speed pump (frequency converter)
Hv
DN 2
Hf
h2 DN 1
h1
(1) m1
L1
TYPE Connection
Collettori mm weight
Peso
DN 1 DN 2 Hv Hf h1 L1 m1 kg
BS1.. 1NM 32/16B/A
G2 G1 1045 875 175 625 365 -
BS1.. 1NM 32/16A/B
BS1.. 1NM 32/20C/A
G2 G1 1045 875 205 625 365 -
BS1.. 1NM 32/20A/B
BS1.. 1NM 32L/16B
G2 G1 1045 875 175 625 365 -
BS1.. 1NM 32L/16A
BS1.. 1NM 32L/20B
G2 G1 1045 875 205 625 365 -
BS1.. 1NM 32L/20A
BS1.. 1NMD 32/210D/B 135
BS1.. 1NMD 32/210C/A 155
G2 G 1 1/4 1045 875 625 365 -
BS1.. 1NMD 32/210B/A 155
BS1.. 1NMD 32/210A/B 175
BS1.. 1NMD 40/180D/B 135
BS1.. 1NMD 40/180C/A 155
G2 G 1 1/2 1045 875 625 365 -
BS1.. 1NMD 40/180B/A 155
BS1.. 1NMD 40/180A/B 175
BS1.. 1NM 40/16B/B
G 2 1/2 G 1 1/2 1045 875 175 625 365 -
BS1.. 1NM 40/16A/C
BS1.. 1NM 40/20B/A 875
G 2 1/2 G 1 1/2 1145 205 625 365 -
BS1.. 1NM 40/20A/A 1145
BS1.. 1NM 40/25B/C
G 2 1/2 G 1 1/2 - - - - - -
BS1.. 1NM 40/25A/C
BS1.. 1NM 50/16B/B
G 2 1/2 G2 - - - - - -
BS1.. 1NM 50/16A/B
BS1.. 1NM 50/20B/C
G 2 1/2 G2 - - - - - -
BS1.. 1NM 50/20A/C
BS1.. 1NM 50/25C/D
BS1.. 1NM 50/25B/C G 2 1/2 G2 - - - - - -
BS1.. 1NM 50/25A/C
BS1.. 1NM 65/16B/C
BS1.. 1NM 65/16AR G3 G 2 1/2 - - - - - -
BS1.. 1NM 65/16A/C
BS1.. 1NM 65/20C/C
BS1.. 1NM 65/20B/C G3 G 2 1/2 - - - - - -
BS1.. 1NM 65/20A/A
BS1.. 1NM 65/25C/A
BS1.. 1NMS 65/250B/A G3 G 2 1/2 - - - - - -
BS1.. 1NMS 65/250A/A
BS1.. 1NM 80/16B/C
100 80 - - - - - -
BS1.. 1NM 80/16A/B
BS1.. 1NM 80/20B
100 80 - - - - - -
BS1.. 1NMS 80/200A
BS1.. 1NM 80/25E
BS1.. 1NMS 80/250D
BS1.. 1NMS 80/250C/A 100 80 - - - - - -
BS1.. 1NMS 80/250B/A
BS1.. 1NMS 80/250A/A
533
BS. NM Pressure boosting sets with 1 to 3 Centrifugal Pumps
Fixed speed pump or Variable speed pump (frequency converter)
L2
DN 2
Hf
Hv
h2
DN 1
h1
3.93.042
(1)
m1
L1 B2
TYPE Connection
Collettori mm weight
Peso
DN 1 DN 2 Hf Hv h1 h2 L1 L2 m1 B B2 kg
BS.. 2NMD 20/110B/A 129 277 670 315 51
G2 G 1 1/2 840 235 600 625
BS.. 2NMD 20/110A/B 129 277 670 315 55
BS.. 2NM 2/A/B G2 G 1 1/2 129 295 620 262 54
BS.. 2NMD 20/140B/A 146 295 670 320 72
G2 G 1 1/2 840 235 600 625
BS.. 2NMD 20/140A/A 146 295 670 320 77
BS.. 2NM 3/C/A 156 307 650 254 71
BS.. 2NM 3/B/A G2 G 1 1/2 867 156 307 650 254 365 600 625 76
BS.. 2NM 3/A/B 156 307 650 254 78
BS.. 2NM 25/20B/C 160 330 725 373 87
BS.. 2NM 25/20A/B G 21/2 G2 840 160 330 725 373 235 600 625 106
BS.. 2NM 25/20S/C 160 330 725 373 114
BS.. 2NMD 25/190C/B 175 330 760 407 108
BS.. 2NMD 25/190B/A G 21/2 G2 840 175 330 760 407 235 600 625 123
BS.. 2NMD 25/190A/B 175 330 760 407 132
BS.. 2NM 32/16B/A 830 1210 266 389
G3 G 21/2 345 304 476 600 625
BS.. 2NM 32/16A/B 830 1210 266 389
BS.. 2NM 32/20C/A 830 1210 294 389
G3 G 21/2 365 324 476 600 625
BS.. 2NM 32/20A/B 830 1210 294 389
BS.. 2NMD 32/210D/B 890 1270 245 420
BS.. 2NMD 32/210C/A 890 1370 272 440
G3 G 21/2 380 460 550 700 800
BS.. 2NMD 32/210B/A 1370 1370 272 440
BS.. 2NMD 32/210A/B 1370 1670 307 515
BS.. 2NMD 40/180D/B 890 1270 245 415
BS.. 2NMD 40/180C/A 890 1370 272 435
G3 G 21/2 460 475 550 700 800
BS.. 2NMD 40/180B/A 1370 1370 272 435
BS.. 2NMD 40/180A/B 1370 1670 307 510
Dimensions not binding to be verified when ordering Dimensions on request Hf= Fixed speed boosting sets
Hv= Variable speed boosting sets
(1) Anti-vibration pads kit supplied loose as standard
534
BS. NM Pressure boosting sets with 1 to 3 Centrifugal Pumps
Fixed speed pump or Variable speed pump (frequency converter)
DN 2
Hv
Hf
DN 1
h2
h1
L1 L2 B2
m1 B
TYPE Connection
Collettori mm weight
Peso
DN 1 DN 2 Hf Hv h1 h2 L1 L2 m1 B B2 kg
BS.. 2NM 32L/16B 830 1210 280 330
100 80 387 487 476 820 800 -
BS.. 2NM 32L/16A 830 1210 280 370
BS.. 2NM 32L/20B 830 1310 320 395
100 80 407 507 1040 820 900 -
BS.. 2NM 32L/20A 1310 1310 320 395
BS.. 2NM 40/16B/B 830 1210 280 395
100 80 387 487 476 820 800 -
BS.. 2NM 40/16A/C 830 1210 280 395
BS.. 2NM 40/20B/A 830 1310 320 425
100 80 407 507 1040 820 900 -
BS.. 2NM 40/20A/A 1310 1310 320 425
BS.. 2NM 40/25B/C 1455 1755 340 540
100 80 452 507 1040 820 900 -
BS.. 2NM 40/25A/C 1455 1755 340 615
BS.. 2NM 50/16B/B 975 1455 315 425
125 100 435 515 - 920 -
BS.. 2NM 50/16A/B 1455 1455 315 425 -
BS.. 2NM 50/20B/C 1455 1755 315 540
125 100 455 515 - 920 -
BS.. 2NM 50/20A/C 1455 1755 315 540
BS.. 2NM 50/25C/D 1455 1755 340 545 -
BS.. 2NM 50/25B/C 125 100 1455 1755 340 480 515 620 - 920 -
BS.. 2NM 50/25A/D 1455 1855 340 620
BS.. 2NM 65/16B/C 1455 1755 320 540 -
BS.. 2NM 65/16AR 200 150 1455 1755 320 525 625 540 - 1020 -
BS.. 2NM 65/16A/C 1455 1755 320 615
BS.. 2NM 65/20C/C 1455 1755 340 615 1020 -
BS.. 2NM 65/20B/C 200 150 1455 1855 340 550 625 615 - 1200 -
BS.. 2NM 65/20A/A 1655 1855 340 725 1200
-
BS.. 2NM 65/25C/A 1655 1855 360 725
BS.. 2NMS 65/250B/A 200 150 1655 1855 360 575 625 725 - 1200 -
-
BS.. 2NMS 65/250A/A 1855 1600* 360 975
BS.. 2NM 80/16B/C 1455 1755 340 620 1050
250 200 615 730 - -
BS.. 2NM 80/16A/D 1455 1855 340 620 1200
BS.. 2NM 80/20B 1655 1855 360 725 -
250 200 640 730 - 1200 -
BS.. 2NMS 80/200A 1655 1855 360 725
BS.. 2NM 80/25E 1655 1855 360 725
BS.. 2NMS 80/250D 1655 1855 360 725
BS.. 2NMS 80/250C/A 250 200 1855 1600* 310 670 730 975 - 1200 -
BS.. 2NMS 80/250B/A 1400* 2100* 310 1040
BS.. 2NMS 80/250A/A 1400* 2100* 310 1110
Dimensions not binding to be verified when ordering Dimensions on request Hf= Fixed speed boosting sets
Hv= Variable speed boosting sets
* Cabinet version
535
BS. NM Pressure boosting sets with 1 to 3 Centrifugal Pumps
Fixed speed pump or Variable speed pump (frequency converter)
DN 2
Hv
Hf
DN 1
h2
h1
L1 L2 B2
m1 B
Connection
Collettori mm weight
TYPE Peso
DN 1 DN 2 Hf Hv h1 h2 L1 L2 m1 B B2 kg
BS.. 3NM 40/16B/B 830 1310 292 395
125 100 400 500 1100 1340 1400 -
BS.. 3NM 40/16A/C 830 1310 292 395
BS.. 3NM 40/20B/A 830 1610 320 425
125 100 420 520 1100 1340 1400 -
BS.. 3NM 40/20A/A 1410 1610 320 425
BS.. 3NM 40/25B/B 1555 1700* 340 540
125 100 465 520 1100 1340 1400 -
BS.. 3NM 40/25A/B 1555 1700* 340 615
BS.. 3NM 50/16B/B 975 1755 315 425
150 125 448 525 - 1340 - -
BS.. 3NM 50/16A/B 1555 1755 315 425
BS.. 3NM 50/20B/C 1555 1700* 315 540
150 125 468 525 - 1340 - -
BS.. 3NM 50/20A/C 1555 1700* 315 540
BS.. 3NM 50/25C/D 1555 1700* 340 545 1440
BS.. 3NM 50/25B/C 150 125 1555 1700* 340 493 525 620 - 1440 - -
BS.. 3NM 50/25A/D 1755 1700* 340 620 -
BS.. 3NM 65/16B/C 1555 1700* 320 540
BS.. 3NM 65/16AR 250 200 1555 1700* 320 555 650 540 - 1540 - -
BS.. 3NM 65/16A/C 1555 1700* 320 615
BS.. 3NM 65/20C/C 1555 1700* 340 615 1540
BS.. 3NM 65/20B/C 250 200 1755 1700* 340 580 650 615 - 1900 - -
BS.. 3NM 65/20A/A 1855 1700* 340 725 1900
BS.. 3NM 65/25C/A 1855 1700* 360 725
BS.. 3NMS 65/250B/A 250 200 1855 1700* 260 605 650 725 - 1900 - -
BS.. 3NMS 65/250A/A 1545 - 310 975
BS.. 3NM 80/16B/C 1555 1700* 340 620
300 250 645 755 - 1900 - -
BS.. 3NM 80/16A/D 1755 1700* 240 620
BS.. 3NM 80/20B 1855 1700* 360 725
300 250 670 755 - 1900 - -
BS.. 3NMS 80/200A 1855 1700* 260 725
BS.. 3NM 80/25E 1855 1700* 360 725
BS.. 3NMS 80/250D 1855 1700* 260 725
BS.. 3NMS 80/250C/A 300 250 1400* - 310 700 755 975 - 1900 - -
BS.. 3NMS 80/250B/A 1400* - 310 1040
BS.. 3NMS 80/250A/A 1400* - 310 1110
Dimensions not binding to be verified when ordering Dimensions on request Hf= Fixed speed boosting sets
Hv= Variable speed boosting sets
* Cabinet version
536
BS. NM. ITT Pressure boosting sets with 2 to 3 Centrifugal Pumps
with I-MAT frequency converter
h2
DN 1
h1
(1) m1 B
L1 L2 B2
Tipo
TYPE Motor
Motore Connection
Collettori mm weight
Peso
kW HP A DN 1 DN 2 H h1 h2 L1 L2 m1 B B2 kg
BS2V 2NM 3/C/A-ITT 1,1 x2 1,5 x2 2,7 x2 876 325
BS2V 2NM 3/B/A-ITT 1,5 x2 2 x2 4,3 x2 G2 G 1 1/2 876 156 307 254 325 365 600 625
BS2V 2NM 3/A/B-ITT 2,2 x2 3 x2 5,3 x2 876 365
BS2V 2NM 25/160B/A-ITT 1,1 x2 1,5 x2 2,7 x2 876 135 305 273 324 365 600 625
G2 G 1 1/2
BS2V 2NM 25/160A/A-ITT 1,5 x2 2 x2 4,3 x2 876
BS2V 2NM 25/20B/C-ITT 2,2 x2 3 x2 5,3 x2 876 370
BS2V 2NM 25/20A/B-ITT 3 x2 4 x2 6,6 x2 G 2 1/2 G2 883 169 330 373 397 365 600 625
BS2V 2NM 25/20S/C-ITT 4 x2 5,5 x2 9,6 x2 883 397
BS2V 2NM 32/16B/A-ITT 1,5 x2 2 x2 4,3 x2 876 330
G3 G 2 1/2 266 304 389 476 600 625
BS2V 2NM 32/16A/B-ITT 2,2 x2 3 x2 5,3 x2 876 370
BS2V 2NM 32/20D/B-ITT 2,2 x2 3 x2 5,3 x2 876 370
BS2V 2NM 32/20C/A-ITT 3 x2 4 x2 6,6 x2 G3 G 2 1/2 876 294 324 389 395 476 600 625
BS2V 2NM 32/20A/B-ITT 4 x2 5,5 x2 9,6 x2 876 395
(1) Anti-vibration pads kit supplied loose as standard
DN 2
H
DN 1
h2
h1
L1 L2 B2
m1 B
Tipo
TYPE Motor
Motore Connection
Collettori mm weight
Peso
kW HP A DN 1 DN 2 H h1 h2 L1 L2 m1 B B2 kg
BS2V 2NM 32L/16B-ITT 3 x2 4 x2 6,6 x2 897 280 330
100 80 387 487 476 820 800
BS2V 2NM 32L/16A-ITT 4 x2 5,5 x2 9,6 x2 897 280 370
BS2V 2NM 32L/20B-ITT 5,5 x2 7,5 x2 10,8 x2 897 320 395
100 80 407 507 1040 820 900
BS2V 2NM 32L/20A-ITT 7,5 x2 10 x2 14,3 x2 897 320 395
BS2V 2NM 40/16C/C-ITT 2,2 x2 3 x2 5,3 x2 897 280 370
BS2V 2NM 40/16B/B-ITT 3 x2 4 x2 6,6 x2 100 80 897 280 387 487 395 476 820 800
BS2V 2NM 40/16A/C-ITT 4 x2 5,5 x2 9,6 x2 897 280 395
BS2V 2NM 40/20D/B-ITT 4 x2 5,5 x2 9,6 x2 897 309 395 476 800
BS2V 2NM 40/20C/B-ITT 4 x2 5,5 x2 9,6 x2 897 309 395 476 800
BS2V 2NM 40/20B/A-ITT 5,5 x2 7,5 x2 10,8 x2 100 80 897 320 407 507 425 1040 820 900
BS2V 2NM 40/20AR/A-ITT 5,5 x2 7,5 x2 10,8 x2 897 320 425 1040 900
BS2V 2NM 40/20A/A-ITT 7,5 x2 10 x2 14,3 x2 897 320 425 1040 900
BS2V 2NM 40/25C/C-ITT 9,2 x2 12,5 x2 18,5 x2 977 340 540
BS2V 2NM 40/25B/C-ITT 11 x2 15 x2 21,5 x2 100 80 977 340 452 507 590 1040 820 -
BS2V 2NM 40/25A/C-ITT 15 x2 20 x2 27,3 x2 977 340 615
BS2V 2NM 50/16B/B-ITT 5,5 x2 7,5 x2 10,8 x2 977 315 425
125 100 435 515 - 920 -
BS2V 2NM 50/16A/B-ITT 7,5 x2 10 x2 14,3 x2 977 315 425
BS2V 2NM 50/20B/C-ITT 9,2 x2 12,5 x2 18,5 x2 977 315 540
BS2V 2NM 50/20A/C-ITT 11 x2 15 x2 21,5 x2 125 100 977 315 455 515 590 - 920 -
BS2V 2NM 50/20S/C-ITT 15 x2 20 x2 27,3 x2 977 315 620
BS2V 2NM 50/25C/C-ITT 11 x2 15 x2 21,5 x2 977 340 595
BS2V 2NM 50/25B/C-ITT 15 x2 20 x2 27,3 x2 125 100 977 340 480 515 620 - 920 -
BS2V 2NM 50/25A/D-ITT 18,5 x2 25 x2 34 x2 977 340 620
BS2V 2NM 65/16D/B-ITT 7,5 x2 10 x2 14,3 x2 977 320 425
BS2V 2NM 65/16C/C-ITT 9,2 x2 12,5 x2 18,5 x2 977 320 540
BS2V 2NM 65/16B/C-ITT 11 x2 15 x2 21,5 x2 200 150 977 320 525 625 540 - 1020 -
BS2V 2NM 65/16AR-ITT 15 x2 20 x2 27,3 x2 977 320 540
BS2V 2NM 65/16A/C-ITT 15 x2 20 x2 27,3 x2 977 320 615
BS2V 2NM 65/20C/C-ITT 15 x2 20 x2 27,3 x2 200 150 977 340 - 445 1020
BS2V 2NM 65/20B/D-ITT 18,5 x2 25 x2 34 x2 977 340 550 - 570 - 1200 -
BS2V 2NM 65/20A/A-ITT 22 x2 30 x2 41 x2 977 360 730 620 1200
BS2V 2NM 65/25C/A-ITT 22 x2 30 x2 41 x2 200 150 977 360 575 725 - 1200 -
BS2V 2NM 80/16E/B-ITT 7,5 x2 10 x2 14,3 x2 977 - 420 1050
BS2V 2NM 80/16D/C-ITT 9,2 x2 12,5 x2 18,5 x2 977 - 545 1050
BS2V 2NM 80/16C/C-ITT 11 x2 15 x2 21,5 x2 250 200 977 - 615 - 595 - 1050 -
BS2V 2NM 80/16B/C-ITT 15 x2 20 x2 27,3 x2 977 340 620 1050
BS2V 2NM 80/16A/D-ITT 18,5 x2 25 x2 34 x2 977 340 620 1200
BS2V 2NM 80/20B-ITT 22 x2 30 x2 41 x2 250 200 - 360 640 725 1200 -
BS2V 2NM 80/25E-ITT 22 x2 30 x2 41 x2 250 200 - 360 670 725 1200 -
BS2V 2NM 100/20E/A-ITT 18,5 x2 25 x2 34 x2
300 250 1490 410 770 1083 662 1835 1200 1200
BS2V 2NM 100/20D-ITT 22 x2 30 x2 41 x2
Dimensions not binding to be verified when ordering
537
BS. NM. ITT Pressure boosting sets with 2 to 3 Centrifugal Pumps
with I-MAT frequency converter
DN 2
h2
DN 1
h1
(1) m1 B
L1 L2 B2
TYPE Motor
Motore Connection
Collettori mm weight
Peso
kW HP A DN 1 DN 2 H h1 h2 L1 L2 m1 B B2 kg
BS3V 3NM 3/C/A-ITT 1,1 x3 1,5 x3 2,7 x3 876 325
BS3V 3NM 3/B/A-ITT 1,5 x3 2 x3 4,3 x3 G 2 1/2 G2 876 171 316 - 325 406 950 1000
BS3V 3NM 3/A/B-ITT 2,2 x3 3 x3 5,3 x3 876 365
BS3V 3NM 25/160B/A-ITT 1,1 x3 1,5 x3 2,7 x3 G2 876 135 290 - 324 406 950 1000
G2
BS3V 3NM 25/160A/A-ITT 1,5 x3 2 x3 4,3 x3 876
BS3V 3NM 25/20B/C-ITT 2,2 x3 3 x3 5,3 x3 876 370
BS3V 3NM 25/20A/B-ITT 3 x3 4 x3 6,6 x3 G3 G 2 1/2 883 184 316 - 397 406 950 1000
BS3V 3NM 25/20S/C-ITT 4 x3 5,5 x3 9,6 x3 883 397
DN 2
H
DN 1
h2
h1
L1 L2 B2
m1 B
TYPE Motor
Motore Connection
Collettori mm weight
Peso
kW HP A DN 1 DN 2 H h1 h2 L1 L2 m1 B B2 kg
BS3V 3NM 32/16B/A-ITT 1,5 x3 2 x3 4,3 x3 876 165 330
100 80 - - - 950 -
BS3V 3NM 32/16A/B-ITT 2,2 x3 3 x3 5,3 x3 876 165 370
BS3V 3NM 32/20D/B-ITT 2,2 x3 3 x3 5,3 x3 876 195 370
BS3V 3NM 32/20C/A-ITT 3 x3 4 x3 6,6 x3 100 80 876 195 - - 395 - 950 -
BS3V 3NM 32/20A/B-ITT 4 x3 5,5 x3 9,6 x3 876 195 395
BS3V 3NM 32L/16-ITT 3 x3 4 x3 6,6 x3 100 876 292 330
125 400 500 1100 1340 1400
BS3V 3NM 32L/16A-ITT 4 x3 5,5 x3 9,6 x3 876 292 370
BS3V 3NM 32L/20B-ITT 5,5 x3 7,5 x3 10,8 x3 100 876 320 395
125 420 500 1100 1340 1400
BS3V 3NM 32L/20A-ITT 7,5 x3 10 x3 14,3 x3 876 320 395
BS3V 3NM 40/16C/C-ITT 2,2 x3 3 x3 5,3 x3 897 292 370
BS3V 3NM 40/16B/B-ITT 3 x3 4 x3 6,6 x3 125 100 897 292 400 500 395 1100 1340 1400
BS3V 3NM 40/16A/C-ITT 4 x3 5,5 x3 9,6 x3 897 292 395
BS3V 3NM 40/20D/B-ITT 4 x3 5,5 x3 9,6 x3 897 320 395
BS3V 3NM 40/20C/B-ITT 4 x3 5,5 x3 9,6 x3 897 320 395
BS3V 3NM 40/20B/A-ITT 5,5 x3 7,5 x3 10,8 x3 125 100 897 320 420 520 425 1100 1340 1400
BS3V 3NM 40/20AR/A-ITT 5,5 x3 7,5 x3 10,8 x3 897 320 425
BS3V 3NM 40/20A/A-ITT 7,5 x3 10 x3 14,3 x3 897 320 425
BS3V 3NM 40/25C/C-ITT 9,2 x3 12,5 x3 18,5 x3 977 340 540
BS3V 3NM 40/25B/C-ITT 11 x3 15 x3 21,5 x3 125 100 977 340 465 520 590 1100 1340 1400
BS3V 3NM 40/25A/D-ITT 15 x3 20 x3 27,3 x3 977 340 615
BS3V 3NM 50/16B/B-ITT 5,5 x3 7,5 x3 10,8 x3 977 315 425
150 125 448 525 - 1340 -
BS3V 3NM 50/16A/B-ITT 7,5 x3 10 x3 14,3 x3 977 315 425
BS3V 3NM 50/20B/C-ITT 9,2 x3 12,5 x3 18,5 x3 977 315 540
- -
BS3V 3NM 50/20A/C-ITT 11 x3 15 x3 21,5 x3 150 125 977 315 468 525 590 1340
BS3V 3NM 50/20S/C-ITT 15 x3 20 x3 27,3 x3 977 315 620 -
BS3V 3NM 50/25C/C-ITT 11 x3 15 x3 21,5 x3 977 340 595 1440
BS3V 3NM 50/25B/C-ITT 15 x3 20 x3 27,3 x3 150 125 977 340 493 525 620 - 1440 -
BS3V 3NM 50/25A/D-ITT 18,5 x3 25 x3 34 x3 977 340 620 -
BS3V 3NM 65/16D/B-ITT 7,5 x3 10 x3 14,3 x3 977 320 425
BS3V 3NM 65/16C/C-ITT 9,2 x3 12,5 x3 18,5 x3 977 320 540
BS3V 3NM 65/16B/C-ITT 11 x3 15 x3 21,5 x3 250 200 977 320 555 650 540 - 1540 -
BS3V 3NM 65/16AR-ITT 15 x3 20 x3 27,3 x3 977 320 540
BS3V 3NM 65/16A/C-ITT 15 x3 20 x3 27,3 x3 977 320 615
BS3V 3NM 65/20C/C-ITT 15 x3 20 x3 27,3 x3 977 340 - 445 1540
BS3V 3NM 65/20B/D-ITT 18,5 x3 25 x3 34 x3 250 200 977 340 580 - 570 - 1900 -
BS3V 3NM 65/20A/A-ITT 22 x3 30 x3 41 x3 977 340 755 620 1900
BS3V 3NM 65/25C/A-ITT 22 x3 30 x3 41 x3 250 200 977 360 605 - 725 - 1900 -
BS3V 3NM 80/16E/B-ITT 7,5 x3 10 x3 14,3 x3 977 340 420
BS3V 3NM 80/16D/C-ITT 9,2 x3 12,5 x3 18,5 x3 977 340 545
BS3V 3NM 80/16C/C-ITT 11 x3 15 x3 21,5 x3 300 250 977 340 645 - 595 - 1900 -
BS3V 3NM 80/16B/C-ITT 15 x3 20 x3 27,3 x3 977 340 620
BS3V 3NM 80/16A/D-ITT 18,5 x3 25 x3 34 x3 977 340 620
BS3V 3NM 80/20B-ITT 22 x3 30 x3 41 x3 300 250 - 360 670 - 725 - 1900 -
BS3V 3NM 80/25E-ITT 22 x3 30 x3 41 x3 300 250 - 360 700 - 725 - 1900 -
BS3V 3NM 100/20E/A-ITT 18,5 x3 25 x3 34 x3 - - - - - 1900 -
350 300 662
BS3V 3NM 100/20D-ITT 22 x3 30 x3 41 x3
Dimensions not binding to be verified when ordering
538
BS. MXH Pressure boosting sets with 1 to 3 Horizontal Multi-Stage Pumps
Fixed speed pump or Variable speed pump (frequency converter)
Coverage chart
10 U.S. g.p.m. 30 40 50 100 200 300 400 500 800
10 Imp. g.p.m. 30 40 50 100 150 200 300 400 500 700
70
60 200
H
ft
50
150
40
H 1-3MXH
m
30 100
20
50
10
0
2 m3/h 5 10 15 20 30 40 50 100 150 200
Q l/min 100 150 200 300 400 500 1000 2000 3000
72.949.C
Operation Construction
BS 1-6F Pressure boosting sets with 1 to 6 fixed speed pump. - Automatic pressure boosting plant consisting of 1 to 6 horizontal multi-
Sets with 4,5 and 6 pumps on request. stage pumps complete with ball, non return valve on the suction side
Depending on the reduction of the pressure in the system, and ball valves on the delivery side.
the pressure switches (pressure transducer for 3-pump sets) Suction and delivery manifolds for boosting sets with 2,3 pumps:
determine the starting up of the pumps in sequence and the - stainless steel AISI 304.
microprocessor alternates the starts. Connections are located on the delivery manifold for the installation of
vessels G1 connection.
BS2-3V Pressure boosting sets with 2 to 3 variable speed pumps Electrical control boards:
(with I-MAT). - with microprocessor for fixed speed pump units. Motor starting is D.O.L.
Depending on water consumption, one or more pumps are up to 5,5 kW and Y/Δ for power rating 7,5 kW.
activated, all at variable speed, in order to guarantee the - with frequency converter for variable speed pump units.
quantity of water required at the set pressure.
The unit includes one pressure gauge and three adjustable differential
BS1-3V Pressure boosting sets with 1 to 3 variable speed pumps pressure switches or pressure transducer.
(with EASYMAT).
Depending on water consumption, one or more pumps are Applications
activated, all at variable speed, in order to guarantee the To supply water in civil and industrial buildings.
quantity of water required at the set pressure. As pressure boosting pump to increase water pressure when needed
(follow local rules).
Motors
BS1V2-5F Pressure boosting sets with 1 variable speed pump (with 2-pole induction motors, 50 Hz, n ≈ 2900 rpm, suitable for operation with
frequency converter into the control panel) and from 1 to 5 frequency converter.
fixed speed pumps - Three-phase 230/400V ± 10% up to 3 kW;
Sets with 4,5 and 6 pumps on request. 400/690V ± 10% for 4 kW to 7,5 kW;
According to the water consumption, one or more pumps - Single-phase 230 V ± 10%, with thermal protector.
start, one at variable speed and the others at fixed speed, Insulation class F.
to grant the water quantity required at the set pressure. Protection IP 54.
Constructed in accordance with: IEC 60034.
Other voltages and frequencies on request.
BS1-6V Pressure boosting sets with 1 to 6 variable speed pumps Vessels on request
(with frequency converter into the control panel). When installing the unit, connect in the delivery section to a diaphragm
Sets with 4,5 and 6 pumps on request. or galvanised tank.
Depending on water consumption, one or more pumps are The recommended sized are shown in the following page.
activated, all at variable speed, in order to guarantee the
quantity of water required at the set pressure. Special features on request
Pressure boosting sets with 4,5 and 6 pumps.
539
BS. MXH Pressure boosting sets with 1 to 3 Horizontal Multi-Stage Pumps
Fixed speed pump or Variable speed pump (frequency converter)
Coverage chart
0 Imp. g.p.m. 15 30 45 0 Imp. g.p.m. 30 60
70 70
50 50
H 150 H 150
m m 6
40
6
40
ft ft
5 5
30 100 30 100
4 4
20 3 20 3
50 50
10 10
0 0
0 m3/h 3 6 9 12 15 0 m3/h 6 12 18 24
0 Q l/min 60 120 180 240 0 Q l/min 150 300
0 0 0 0
0 3
Q m /h 10 20 30 40 0 Q m 3/h 20 30 40 50 60 70 80
0 l/min 200 300 400 500 600 700 0 l/min 400 600 800 1000 1200
0 U.S. g.p.m. 75 150 225 300 0 Imp. g.p.m. 200 300 400 500
90 80
80 ft 70 ft
1-3MXH 20 1-3MXH 32
70 60 200
5
60 200 H
m 4
H 4
m 40
40 3 3
30 100
30 100
2 2
20
20
10 10
0 0 0 0
0 3 20 30 40 50 60 70 75 0 m 3/h 50 100 150
Q m /h Q l/min
0 l/min 300 600 900 1200 0 500 1000 1500 2000 2500
60 200
H 1-3MXH 48
m
ft
40
3
30 100
2
20
10
0 0
0 m3/h 30 60 90 120 150 180 210
Q
0 l/min 500 1000 1500 2000 2500 3000 3500
540
BS. MXH Pressure boosting sets with 1 to 3 Horizontal Multi-Stage Pumps
Fixed speed pump or Variable speed pump (frequency converter)
Performance
BS1F BSM1F
Mains: 400V 3~ Mains: 230V 1~ Motor Pres. switch 1 Vessel Vessel
Motor: 400V 3~ Motor: 230V 1~ bar Membrane
kW HP min max litre litre
BS1F 1MXH 203E BSM1F 1MXHM 203E 0,45 0,6 1,4 2,8 24 100
BS1F 1MXH 204/A BSM1F 1MXHM 204/A 0,55 0,75 2,8 4 40 100
BS1F 1MXH 205/B BSM1F 1MXHM 205/A 0,75 1 3,5 5 50 100
BS1F 1MXH 206/C BSM1F 1MXHM 206 1,1 1,5 4 6 50 100
BS1F 1MXH 403/A BSM1F 1MXHM 403/A 0,55 0,75 1,4 2,6 60 100
BS1F 1MXH 404/B BSM1F 1MXHM 404/A 0,75 1 2,4 3,6 80 200
BS1F 1MXH 405/C BSM1F 1MXHM 405 1,1 1,5 3,4 4,9 100 200
BS1F 1MXH 406/A BSM1F 1MXHM 406 1,5 2 4 6 100 200
BS1F 1MXH 803/A BSM1F 1MXHM 803 1,1 1,5 1,6 2,8 100 300
BS1F 1MXH 804/A BSM1F 1MXHM 804 1,5 2 2,8 4 200 300
BS1F 1MXH 805/B 1,8 2,5 3,5 5 200 500
BS1F 1MXH 1603/B 1,8 2,5 1,5 3 300 500
BS1F 1MXH 1604/A 3 4 2,8 4 500 1000
BS1F 1MXH 1605/B 3,7 5 3,8 5,3 500 1000
BS1F 1MXH 1606/B 4 5,5 4,5 6,5 500 800
BS1F 1MXH 2002/A 1,8 2,5 1,5 2,8 300 500
BS1F 1MXH 2003 3 4 3 4,5 500 1000
BS1F 1MXH 2004/A 4 5,5 4,4 5,9 1000 1500
BS1F 1MXH 2005 5,5 7,5 5,5 7 1000 1500
BS1F 1MXH-F 3202/B 4 5,5 1,5 3 1000 2000
BS1F 1MXH-F 3203/A 5,5 7,5 3 4,5 1000 2000
BS1F 1MXH-F 3204/A 7,5 10 4 6 1500 3000
BS1F 1MXH-F 4802/A 5,5 7,5 1,5 3 1500 2000
BS1F 1MXH-F 4803/A 7,5 10 3 4,5 2000 3000
BS2F BSM2F
Mains: 400V 3~ Alimentazione 230V 1~ Motor Pres. switch 1 Pres. switch 2 Vessel Vessel
Motor: 400V 3~ Motore 230V 1~ bar bar Membrane
kW HP min max min max litre litre
BS2F 2MXH 203E BSM2F 2MXHM 203E 0,45 x2 0,6 x2 1,4 2,8 1 2,4 24 100
BS2F 2MXH 204/A BSM2F 2MXHM 204/A 0,55 x2 0,75 x2 2,8 4 2,4 3,6 40 100
BS2F 2MXH 205/B BSM2F 2MXHM 205/A 0,75 x2 1 x2 3,5 5 3 4,5 50 100
BS2F 2MXH 206/C BSM2F 2MXHM 206 1,1 x2 1,5 x2 4 6 3,5 5,5 50 100
BS2F 2MXH 403/A BSM2F 2MXHM 403/A 0,55 x2 0,75 x2 1,4 2,6 1 2,2 60 100
BS2F 2MXH 404/B BSM2F 2MXHM 404/A 0,75 x2 1 x2 2,4 3,6 2 3,2 80 200
BS2F 2MXH 405/C BSM2F 2MXHM 405 1,1 x2 1,5 x2 3,4 4,9 3 4,5 100 200
BS2F 2MXH 406/A BSM2F 2MXHM 406 1,5 x2 2 x2 4 6 3,5 5,5 100 200
BS2F 2MXH 803/A BSM2F 2MXHM 803 1,1 x2 1,5 x2 1,6 2,8 1,2 2,4 100 300
BS2F 2MXH 804/A BSM2F 2MXHM 804 1,5 x2 2 x2 2,8 4 2,4 3,6 200 300
BS2F 2MXH 805/B 1,8 x2 2,5 x2 3,5 5 3 4,5 200 500
BS2F 2MXH 1603/B 1,8 x2 2,5 x2 1,5 3 1,2 2,7 300 500
BS2F 2MXH 1604/A 3 x2 4 x2 2,8 4 2,4 3,6 500 1000
BS2F 2MXH 1605/B 3,7 x2 5 x2 3,8 5,3 3,4 4,9 500 1000
BS2F 2MXH 1606/B 4 x2 5,5 x2 4,5 6,5 4 6 500 800
BS2F 2MXH 2002/A 1,8 x2 2,5 x2 1,5 2,8 1,2 2,5 300 500
BS2F 2MXH 2003 3 x2 4 x2 3 4,5 2,5 4 500 1000
BS2F 2MXH 2004/A 4 x2 5,5 x2 4,4 5,9 3,9 5,4 1000 1500
BS2F 2MXH 2005 5,5 x2 7,5 x2 5,5 7 5,1 6,6 1000 1500
BS2F 2MXH-F 3202/B 4 x2 5,5 x2 1,5 3 1,2 2,7 1000 2000
BS2F 2MXH-F 3203/A 5,5 x2 7,5 x2 3 4,5 2,5 4 1000 2000
BS2F 2MXH-F 3204/A 7,5 x2 10 x2 4 6 3,5 5,5 1500 3000
BS2F 2MXH-F 4802/A 5,5 x2 7,5 x2 1,5 3 1,2 2,7 1500 2000
BS2F 2MXH-F 4803/A 7,5 x2 10 x2 3 4,5 2,5 4 2000 3000
BS3F
Mains: 400V 3~ Motor Pressure transducer Vessel Vessel
Motor: 400V 3~ bar Membrane
kW HP min max litre litre
BS3F 3MXH 203E 0,45 x3 0,6 x3 2 2,8 24x2 100
BS3F 3MXH 204/A 0,55 x3 0,75 x3 2,9 3,8 24x2 100
BS3F 3MXH 205/B 0,75 x3 1 x3 3,3 4,8 24x2 100
BS3F 3MXH 206/C 1,1 x3 1,5 x3 4,2 5,9 60 100
BS3F 3MXH 403/A 0,55 x3 0,75 x3 1,9 2,7 80 200
BS3F 3MXH 404/B 0,75 x3 1 x3 2,8 3,6 100 200
BS3F 3MXH 405/C 1,1 x3 1,5 x3 3,2 4,7 100 200
BS3F 3MXH 406/A 1,5 x3 2 x3 4 5,7 150 200
BS3F 3MXH 803/A 1,1 x3 1,5 x3 2,1 2,9 200 500
BS3F 3MXH 804/A 1,5 x3 2 x3 2,9 3,8 300 500
BS3F 3MXH 805/B 1,8 x3 2,5 x3 3,4 4,9 300 500
BS3F 3MXH 1603/B 1,8 x3 2,5 x3 2,2 3 300 800
BS3F 3MXH 1604/A 3 x3 4 x3 3,3 4,2 500 1000
BS3F 3MXH 1605/B 3,7 x3 5 x3 3,6 5,2 500 1000
BS3F 3MXH 1606/B 4 x3 5,5 x3 4,4 6,1 500 1000
BS3F 3MXH 2003 3 x3 4 x3 3,4 4,3 500 800
BS3F 3MXH 2004/A 4 x3 5,5 x3 4,1 5,8 500 1000
BS3F 3MXH 2005 5,5 x3 7,5 x3 5,4 7,3 750 1500
BS3F 3MXH-F 3202/B 4 x3 5,5 x3 2,1 2,9 1000 2000
BS3F 3MXH-F 3203/A 5,5 x3 7,5 x3 2,9 4,4 1000 2000
BS3F 3MXH-F 3204/A 7,5 x3 10 x3 4,3 6 1500 3000
BS3F 3MXH-F 4802/A 5,5 x3 7,5 x3 2,3 3,1 1500 3000
BS3F 3MXH-F 4803/A 7,5 x3 10 x3 3,2 4,7 1500 3000
541
BS. MXH Pressure boosting sets with 1 to 3 Horizontal Multi-Stage Pumps
Fixed speed pump or Variable speed pump (frequency converter)
Performance
542
BS. MXH Pressure boosting sets with 1 to 3 Horizontal Multi-Stage Pumps
Fixed speed pump or Variable speed pump (frequency converter)
Hv
Hf
DN2
h2
DN1
h1
(1) m1 B2
TYPE Connection
Collettori mm weight
Peso
DN 1 DN 2 Hv Hf h1 h2 m1 B2 kg
BS1.. 1MXH 203E -
BS1.. 1MXH 204/A
G 1 1/4 G1 1045 875 170 145 625 365
BS1.. 1MXH 205/B
BS1.. 1MXH 206/C
BS1.. 1MXH 403/A
BS1.. 1MXH 404/B
G 1 1/4 G1 1045 875 170 145 625 365
BS1.. 1MXH 405/C
BS1.. 1MXH 406/A
BS1.. 1MXH 803/A
BS1.. 1MXH 804/A G 1 1/2 G1 1045 875 170 145 625 365
BS1.. 1MXH 805/B
BS1.. 1MXH 1603/B
BS1.. 1MXH 1604/A
G 1 1/2 G 1 1/2 1045 875 175 195 625 365
BS1.. 1MXH 1605/B
BS1.. 1MXH 1606/B
Dimensions not binding to be verified when ordering (1) Anti-vibration pads kit supplied loose as standard
DN 2
Hv
Hf
DN 1
h2
h1
m1 B2
(1)
TYPE Connection
Collettori weight
mm Peso
DN 1 DN 2 Hv Hf h1 h2 m1 B2 kg
BS1.. 1MXH 2002/A
BS1.. 1MXH 2003 G2 G 1 1/2 1045 875 195 197 625 365
BS1.. 1MXH 2004/A
BS1.. 1MXH 2005 1145 1145
BS1.. 1MXH-F 3202/B
BS1.. 1MXH-F 3203/A 65 50 1045 875 195 265 625 365
BS1.. 1MXH-F 3204/A
BS1.. 1MXH-F 4802/A
80 65 1145 1145 195 275 625 365
BS1.. 1MXH-F 4803/A
Dimensions not binding to be verified when ordering (1) Anti-vibration pads kit supplied loose as standard
543
BS. MXH Pressure boosting sets with 1 to 3 Horizontal Multi-Stage Pumps
Fixed speed pump or Variable speed pump (frequency converter)
L2
DN 2
L2
DN 2
Hv-Hf
Hv
DN 1
h2
Hf
h2 DN 1
h1
h1
3.93.043
m1 m1 B2
(1)
L1 B2 L1v-L1f
Connection
Collettori mm weight
TYPE Peso
DN 1 DN 2 Hf Hv h1 h2 L1f L1v L2 m1 B2 B kg
BS.. 2MXH 203E G2 G 11/2 840 - 162 202 773 - 335 42
BS.. 2MXH 204/A G2 G 11/2 840 - 162 202 796 - 358 47
BS.. 2MXH 205/B G2 G 11/2 840 - 162 202 820 - 382 50
BS.. 2MXH 206/C G2 G 11/2 840 - 162 202 845 - 406 54
BS.. 2MXH 403/A G2 G 11/2 840 - 162 202 773 - 335 46
BS.. 2MXH 404/B G2 G 11/2 840 - 162 202 796 - 358 49
BS.. 2MXH 405/C G2 G 11/2 840 - 162 202 820 - 382 235 625 600 53
BS.. 2MXH 406/A G2 G 11/2 840 - 162 202 845 - 406 57
BS.. 2MXH 803/A G 21/2 G2 840 - 162 208 866 - 428 61
BS.. 2MXH 804/A G 21/2 G2 840 - 162 208 896 - 458 66
BS.. 2MXH 805/B G 21/2 G2 840 - 162 208 926 - 488 68
BS.. 2MXH 1603/B G3 G 21/2 1040 980 258 281 1050 1115 490 -
BS.. 2MXH 1604/A G3 G 21/2 1040 980 273 281 1085 1150 530 -
1090 625 600
BS.. 2MXH 1605/B G3 G 21/2 1040 980 273 281 1120 1185 565 -
BS.. 2MXH 1606/B G3 G 21/2 1040 980 273 281 1178 1245 605 -
BS.. 2MXH 2002/A G3 G 2 1/2 1040 980 220 351 1155 1220 484 -
BS.. 2MXH 2003 G3 G 2 1/2 1040 980 230 351 1155 1220 503 1090 625 600 -
BS.. 2MXH 2004/A G3 G 2 1/2 1040 980 230 351 1180 1245 537 -
BS.. 2MXH 2005 G3 G 2 1/2 1040 980 252 351 1230 1295 572 -
Dimensions not binding to be verified when ordering (1) Anti-vibration pads kit supplied loose as standard Hf= Fixed speed boosting sets
Hv= Variable speed boosting sets
DN 2
L2
Hv-Hf
DN 1
h2
h1
3.93.155
m1 B2
L1f-L1v
TYPE Connection
Collettori mm weight
Peso
DN 1 DN 2 Hf Hv h1 h2 L1f L1v L2 m1 B2 B kg
BS.. 2MXH-F 3202/B 100 80 1510 - 298 402 1265 - 558 1175 214
BS.. 2MXH-F 3203 100 80 1510 - 298 402 1270 - 604 1150 243
BS.. 2MXH-F 3204/A 100 80 1510 - 298 402 1320 - 650 1175 750 750 260
BS.. 2MXH-F 4802/A 125 100 1510 - 298 465 1380 - 654 1175 268
BS.. 2MXH-F 4803/A 125 100 1510 - 298 465 1420 - 716 1220 286
Dimensions not binding to be verified when ordering
544
BS. MXH Pressure boosting sets with 1 to 3 Horizontal Multi-Stage Pumps
Fixed speed pump or Variable speed pump (frequency converter)
L2
DN 2
L2
H
DN 2
Hv
h2
DN 1
Hf
h2 DN 1
h1
h1
3.93.043
m1
m1 B2
(1)
L1 B2
L1
TYPE Connection
Collettori mm weight
Peso
DN 1 DN 2 Hf Hv h1 h2 L1f L1v L2 m1 B2 B kg
BS.. 3MXH 203E G 2 1/2 G2 840 - 162 202 773 - 335 -
BS.. 3MXH 204/A G 2 1/2 G2 840 - 162 202 796 - 358
BS.. 3MXH 205/B G 2 1/2 G2 840 - 162 202 820 - 382
BS.. 3MXH 206/C G 2 1/2 G2 840 - 162 202 845 - 406
BS.. 3MXH 403/A G 2 1/2 G2 840 - 162 202 773 - 335
BS.. 3MXH 404/B G 2 1/2 G2 840 - 162 202 796 - 358
BS.. 3MXH 405/C G 2 1/2 G2 840 - 162 202 820 - 382 305 1000 950
BS.. 3MXH 406/A G 2 1/2 G2 840 - 162 202 845 - 406
BS.. 3MXH 803/A G3 G 21/2 840 - 162 208 866 - 428
BS.. 3MXH 804/A G3 G 21/2 840 - 162 208 896 - 458
BS.. 3MXH 805/B G3 G 21/2 840 - 162 208 926 - 488
BS.. 3MXH 1603/B DN 100 DN 80 1060 1550 258 327 1096 1100 500
BS.. 3MXH 1604/A DN 100 DN 80 1060 1550 273 327 1131 1135 538
1090 1000 950
BS.. 3MXH 1605/B DN 100 DN 80 1060 1550 273 327 1167 1171 575
BS.. 3MXH 1606/B DN 100 DN 80 1060 1550 273 327 1227 1231 613
BS.. 3MXH 2002/A DN 100 DN 80 1060 1550 290 398 1166 1170 499
BS.. 3MXH 2003 DN 100 DN 80 1060 1550 290 398 1166 1170 518 1090 1000 950
BS.. 3MXH 2004/A DN 100 DN 80 1060 1550 290 398 1226 1230 553
BS.. 3MXH 2005 DN 100 DN 80 1060 1550 252 398 1241 1245 587
Dimensions not binding to be verified when ordering (1) Anti-vibration pads kit supplied loose as standard Hf= Fixed speed boosting sets
Hv= Variable speed boosting sets
DN 2
L2
Hv-Hf
DN 1
h2
h1
3.93.155
m1 B2
L1f-L1v
Connection
Collettori mm weight
TYPE Peso
DN 1 DN 2 Hf Hv h1 h2 L1f L1v L2 m1 B2 B kg
BS.. 3MXH-F 3202/B 125 100 1510 - 318 415 1265 - 565 1175 -
BS.. 3MXH-F 3203/A 125 100 1510 - 318 415 1270 - 617 1060
BS.. 3MXH-F 3204/A 125 100 1510 - 318 415 1320 - 660 1175 1150 1200
BS.. 3MXH-F 4802/A 150 125 1510 - 318 465 1380 - 665 1175
BS.. 3MXH-F 4803/A 150 125 1510 - 318 465 1420 - 725 1220
Dimensions not binding to be verified when ordering
545
BS. MXH. EM Pressure boosting sets with 1 to 3 horizontal multi-stage
pumps with EASYMAT frequency converter
DN2
h2
H
DN1
h1
4.93.334.1
m1 B2
L2
L1
Aliment.:
Mains: 1~ 230 V
1 ~230V Aliment.:
Mains: ~230 V
1~1230V Connection mm
Motore: 230 V
3 ~230V ~230 V
Motore:1~1230V P2
Motor: 3~ mains motor
aliment. motore Motor:
A A A kW HP DN1 DN2 H h1 h2 L1 L2 m1 B B2
BSM1V 1MXH 203E-EMT 3,2 2,4 BSM1V 1MXHM 203E-EMM 3 0,45 0,6 511 274
BSM1V 1MXH 204/A-EMT 4 2,8 BSM1V 1MXHM 204/A-EMM 4,2 0,55 0,75 561 298
G 1 1/4 G1 708 127 516 88 165 146
BSM1V 1MXH 205/B-EMT 5 3,5 BSM1V 1MXHM 205/A-EMM 5,4 0,75 1 585 322
BSM1V 1MXH 206/C-EMT 6,3 4,7 BSM1V 1MXHM 206-EMM 7,4 1,1 1,5 609 346
BSM1V 1MXH 403/A-EMT 4 2,8 BSM1V 1MXHM 403/A-EMM 4,2 0,55 0,75 537 274
BSM1V 1MXH 404/B-EMT 5 3,5 BSM1V 1MXHM 404/A-EMM 5,4 0,75 1 561 298
G 1 1/4 G1 708 127 516 88 165 146
BSM1V 1MXH 405/C-EMT 6,7 4,7 BSM1V 1MXHM 405-EMM 7,4 1,1 1,5 585 322
BSM1V 1MXH 406/A-EMT 8 6,2 1,5 2 680 346
BSM1V 1MXH 803/A-EMT 7,1 5 BSM1V 1MXHM 803-EMM 7,4 1,1 1,5 657 323
BSM1V 1MXH 804/A-EMT 8,6 6,2 1,5 2 G 1 1/2 G1 708 127 516 687 353 88 165 146
BSM1V 1MXH 805/B-EMT 10,7 7,5 1,8 2,5 717 383
BSM1V 1MXH 1602/A-EMT 9,1 6,2 1,5 2 752 404
G2 G 1 1/2 750 117 560 101 165 146
BSM1V 1MXH 1603/B-EMT 10,7 7,5 1,8 2,5 752 404
546
BS. MXH. EM Pressure boosting sets with 1 to 3 horizontal multi-stage
pumps with EASYMAT frequency converter
DN2
h2
H
DN1
h1
(1)
m1
B
L2
B2
L1
Aliment.:
Mains: 1~ 1~ 230 V
230V Connection mm
Motore: 3~ 230 V P2
Motor: 3~ 230V mains motore
aliment. motor
A A kW HP DN1 DN2 H h1 h2 L1 L2 m1 B B2
BSM2V 2MXH 203E-EMT 2 x 3,2 2 x 2,4 2 x 0,45 2 x 0,6 563 326
BSM2V 2MXH 204/A-EMT 2x4 2 x 2,8 2 x 0,55 2 x 0,75 613 350
G2 G 1 1/2 848 161 506 240 600 625
BSM2V 2MXH 205/B-EMT 2x5 2 x 3,5 2 x 0,75 2x1 637 374
BSM2V 2MXH 206/C-EMT 2 x 6,3 2 x 4,7 2 x 1,1 2 x 1,5 661 398
BSM2V 2MXH 403/A-EMT 2x4 2 x 2,8 2 x 0,55 2 x 0,75 589 326
BSM2V 2MXH 404/B-EMT 2x5 2 x 3,5 2 x 0,75 2x1 613 350
G2 G 1 1/2 848 161 506 240 600 625
BSM2V 2MXH 405/C-EMT 2 x 6,7 2 x 4,7 2 x 1,1 2 x 1,5 637 374
BSM2V 2MXH 406/A-EMT 2x8 2 x 6,2 2 x 1,5 2x2 732 398
BSM2V 2MXH 803/A-EMT 2 x 7,1 2x5 2 x 1,1 2 x 1,5 727 393
BSM2V 2MXH 804/A-EMT 2 x 8,6 2 x 6,2 2 x 1,5 2x2 G 2 1/2 G2 854 161 512 757 423 240 600 625
BSM2V 2MXH 805/B-EMT 2 x 10,7 2 x 7,5 2 x 1,8 2 x 2,5 787 453
BSM2V 2MXH 1602/A-EMT 2 x 9,1 2 x 6,2 2 x 1,5 2x2 829 481
G3 G 2 1/2 882 151 551 240 600 625
BSM2V 2MXH 1603/B-EMT 2 x 10,7 2 x 7,5 2 x 1,8 2 x 2,5 829 481
Dimensions not binding to be verified when ordering (1) Anti-vibration pads kit supplied loose as standard
DN2
h2
H
DN1
h1
(1)
m1
B L2
B2 L1
Mains: 1~
Aliment.: 230V
1~ 230 V Connection mm
Motore: 3~ 230 V P2
Motor: 3~ 230V mains motore
aliment. motor
A A kW HP DN1 DN2 H h1 h2 L1 L2 m1 B B2
BSM3V 3MXH 203E-EMT 3 x 3,2 3 x 2,4 3 x 0,45 3 x 0,6 563 326
BSM3V 3MXH 204/A-EMT 3x4 3 x 2,8 3 x 0,55 3 x 0,75 613 350
G2 G 1 1/2 848 161 506 240 600 625
BSM3V 3MXH 205/B-EMT 3x5 3 x 3,5 3 x 0,75 3x1 637 374
BSM3V 3MXH 206/C-EMT 3 x 6,3 3 x 4,7 3 x 1,1 3 x 1,5 661 398
BSM3V 3MXH 403/A-EMT 3x4 3 x 2,8 3 x 0,55 3 x 0,75 589 326
BSM3V 3MXH 404/B-EMT 3x5 3 x 3,5 3 x 0,75 3x1 613 350
G2 G 1 1/2 848 161 506 240 600 625
BSM3V 3MXH 405/C-EMT 3 x 6,7 3 x 4,7 3 x 1,1 3 x 1,5 637 374
BSM3V 3MXH 406/A-EMT 3x8 3 x 6,2 3 x 1,5 3x2 732 398
BSM3V 3MXH 803/A-EMT 3 x 7,1 3x5 3 x 1,1 3 x 1,5 727 393
BSM3V 3MXH 804/A-EMT 3 x 8,6 3 x 6,2 3 x 1,5 3x2 G 2 1/2 G2 854 161 512 757 423 240 600 625
BSM3V 3MXH 805/B-EMT 3 x 10,7 3 x 7,5 3 x 1,8 3 x 2,5 787 453
BSM3V 3MXH 1602/A-EMT 3 x 9,1 3 x 6,2 3 x 1,5 3x2 829 481
G3 G 2 1/2 882 151 551 240 600 625
BSM3V 3MXH 1603/B-EMT 3 x 10,7 3 x 7,5 3 x 1,8 3 x 2,5 829 481
Dimensions not binding to be verified when ordering (1) Anti-vibration pads kit supplied loose as standard
547
BS. MXH. ITT Pressure boosting sets with 2 to 3 horizontal
multi-stage pumps with I-MAT frequency converter
L2 DN 2
L2
HI
HI DN 1
h2
h2
h1
h1
m1 B2
m1
(1) L1I
L1I B2
TYPE Motore
Motor Collettori
Connection mm weight
Peso
kW HP A DN 1 DN 2 HI h1 h2 L1I L2 m1 B2 B kg
BS2V 2MXH 204/A-ITT 0,55 x2 0,75 x2 1,6 x2 G2 G 1 1/2 848 162 187 725 347 47
BS2V 2MXH 205/B-ITT 0,75 x2 1 x2 2 x2 G2 G 1 1/2 848 162 187 749 371 50
BS2V 2MXH 206/C-ITT 1,1 x2 1,5 x2 2,7 x2 G2 G 1 1/2 848 162 187 773 395 54
BS2V 2MXH 403/A-ITT 0,55 x2 0,75 x2 1,6 x2 G2 G 1 1/2 848 162 187 701 323 46
BS2V 2MXH 404/B-ITT 0,75 x2 1 x2 2 x2 G2 G 1 1/2 848 162 187 725 347 49
BS2V 2MXH 405/C-ITT 1,1 x2 1,5 x2 2,7 x2 G2 G 1 1/2 848 162 187 749 371 235 625 600 53
BS2V 2MXH 406/A-ITT 1,5 x2 2 x2 3,6 x2 G2 G 1 1/2 848 162 187 773 295 57
BS2V 2MXH 803/A-ITT 1,1 x2 1,5 x2 2,7 x2 G 2 1/2 G2 848 162 193 764 386 61
BS2V 2MXH 804/A-ITT 1,5 x2 2 x2 3,6 x2 G 2 1/2 G2 848 162 193 794 416 66
BS2V 2MXH 805/B-ITT 1,8 x2 2,5 x2 4,3 x2 G 2 1/2 G2 848 162 193 830 446 68
BS2V 2MXH 1603/B-ITT 1,8 x2 2,5 x2 4,3 x2 G3 G 2 1/2 980 258 281 1065 490 87
BS2V 2MXH 1604/A-ITT 3 x2 4 x2 6,6 x2 G3 G 2 1/2 980 273 281 1100 530 114
BS2V 2MXH 1605/B-ITT 3,7 x2 5 x2 9,6 x2 G3 G 2 1/2 980 273 281 1133 565 122
BS2V 2MXH 1606/B-ITT 4 x2 5,5 x2 9,6 x2 G3 G 2 1/2 980 273 281 1192 605 124
BS2V 2MXH 2001/A-ITT 1,1 x2 1,5 x2 2,7 x2 G3 G 2 1/2 980 220 351 1170 484
1090 625 600
BS2V 2MXH 2002/A-ITT 1,8 x2 2,5 x2 5,3 x2 G3 G 2 1/2 980 220 351 1170 484
BS2V 2MXH 2003-ITT 3 x2 4 x2 6,6 x2 G3 G 2 1/2 980 230 351 1170 503
BS2V 2MXH 2004/A-ITT 4 x2 5,5 x2 9,6 x2 G3 G 2 1/2 980 230 351 1195 537
BS2V 2MXH 2005-ITT 5,5 x2 7,5 x2 10,9 x2 G3 G 2 1/2 980 252 351 1245 572
Dimensions not binding to be verified when ordering (1) Anti-vibration pads kit supplied loose as standard
L2 B
DN 2
DN 1
h2
HI
h1
3.93.155
m1 B2
L1I
TYPE Motor
Motore Connection
Collettori mm weight
Peso
kW HP A DN 1 DN 2 HI h1 h2 L1I L2 m1 B2 B kg
BS2V 2MXH-F 3201/B-ITT 2,2 x2 3 x2 5,3 x2 100 80 1100 266 402 1164 558 990 214
BS2V 2MXH-F 3202/B-ITT 4 x2 5,5 x2 9,6 x2 100 80 1180 298 402 1180 558 1010 243
BS2V 2MXH-F 3203/A-ITT 5,5 x2 7,5 x2 10,9 x2 100 80 1180 298 402 1274 604 1050 260
BS2V 2MXH-F 3204/A-ITT 7,5 x2 10 x2 14,3 x2 100 80 1180 298 402 1320 650 1110 750 750
BS2V 2MXH-F 4801/A-ITT 3 x2 4 x2 6,6 x2 125 100 1198 298 468 1250 654 1010 268
BS2V 2MXH-F 4802/A-ITT 5,5 x2 7,5 x2 10,9 x2 125 100 1198 298 468 1306 654 1065 286
BS2V 2MXH-F 4803/A-ITT 7,5 x2 10 x2 14,3 x2 125 100 1198 298 468 1367 716 1110
Dimensions not binding to be verified when ordering
548
BS. MXH. ITT Pressure boosting sets with 2 to 3 horizontal
multi-stage pumps with I-MAT frequency converter
L2
DN 2
L2
H
HI
h2
DN 1
h2
h1
h1
m1 m1 B2
(1)
L1
L1I B2
TYPE Motore
Motor Collettori
Connection mm weight
Peso
kW HP A DN 1 DN 2 HI h1 h2 L1I L2 m1 B2 B kg
BS3V 3MXH 204/A-ITT 0,55 x3 0,75 x3 1,6 x3 G 2 1/2 G2 913 227 193 857 356 -
BS3V 3MXH 205/B-ITT 0,75 x3 1 x3 2 x3 G 2 1/2 G2 913 227 193 881 380
BS3V 3MXH 206/C-ITT 1,1 x3 1,5 x3 2,7 x3 G 2 1/2 G2 913 227 193 905 404
BS3V 3MXH 403/A-ITT 0,55 x3 0,75 x3 1,6 x3 G 2 1/2 G2 913 227 193 833 332
BS3V 3MXH 404/B-ITT 0,75 x3 1 x3 2 x3 G 2 1/2 G2 913 227 193 857 356
BS3V 3MXH 405/C-ITT 1,1 x3 1,5 x3 2,7 x3 G 2 1/2 G2 913 227 193 881 390 423 1000 950
BS3V 3MXH 406/A-ITT 1,5 x3 2 x3 3,6 x3 G 2 1/2 G2 913 227 193 905 404
BS3V 3MXH 803/A-ITT 1,1 x3 1,5 x3 2,7 x3 G3 G 21/2 913 227 193 905 404
BS3V 3MXH 804/A-ITT 1,5 x3 2 x3 3,6 x3 G3 G 21/2 913 227 193 933 432
BS3V 3MXH 805/B-ITT 1,8 x3 2,5 x3 4,3 x3 G3 G 21/2 913 227 193 950 449
BS3V 3MXH 1603/B-ITT 1,8 x3 2,5 x3 4,3 x3 DN 100 DN 80 980 258 321 1100 500
BS3V 3MXH 1604/A-ITT 3 x3 4 x3 6,6 x3 DN 100 DN 80 980 273 321 1135 538
BS3V 3MXH 1605/B-ITT 3,7 x3 5 x3 9,6 x3 DN 100 DN 80 980 273 321 1171 575
BS3V 3MXH 1606/B-ITT 4 x3 5,5 x3 9,6 x3 DN 100 DN 80 980 273 321 1231 613
BS3V 3MXH 2001/A-ITT 1,1 x3 1,5 x3 2,7 x3 DN 100 DN 80 980 290 391 1170 499
1090 1000 950
BS3V 3MXH 2002/A-ITT 1,8 x3 2,5 x3 5,3 x3 DN 100 DN 80 980 290 391 1170 499
BS3V 3MXH 2003-ITT 3 x3 4 x3 6,6 x3 DN 100 DN 80 980 290 391 1170 518
BS3V 3MXH 2004/A-ITT 4 x3 5,5 x3 9,6 x3 DN 100 DN 80 980 290 391 1230 553
BS3V 3MXH 2005-ITT 5,5 x3 7,5 x3 10,9 x3 DN 100 DN 80 980 252 391 1245 587
Dimensions not binding to be verified when ordering (1) Anti-vibration pads kit supplied loose as standard
L2 B
DN 2
DN 1
h2
HI
h1
3.93.155
m1 B2
L1I
TYPE Motor
Motore Connection
Collettori mm weight
Peso
kW HP A DN 1 DN 2 HI h1 h2 L1I L2 m1 B2 B kg
BS3V 3MXH-F 3201/B-ITT 2,2 x3 3 x3 5,3 x3 125 100 1246 286 415 1164 571 1010 -
BS3V 3MXH-F 3202/B-ITT 4 x3 5,5 x3 9,6 x3 125 100 1246 318 415 1180 571 1065
BS3V 3MXH-F 3203/A-ITT 5,5 x3 7,5 x3 10,9 x3 125 100 1246 318 415 1096 617 1060
BS3V 3MXH-F 3204/A-ITT 7,5 x3 10 x3 14,3 x3 125 100 1246 318 415 1320 663 1110 1150 1200
BS3V 3MXH-F 4801/A-ITT 3 x3 4 x3 6,6 x3 150 125 1246 316 480 1272 668 1010
BS3V 3MXH-F 4802/A-ITT 5,5 x3 7,5 x3 10,9 x3 150 125 1246 316 480 1320 668 1065
BS3V 3MXH-F 4803/A-ITT 7,5 x3 10 x3 14,3 x3 150 125 1246 316 480 1381 750 1110
Dimensions not binding to be verified when ordering
549
BS. MXP, MGP Pressure boosting sets with 1 to 3
Fixed speed pump or Variable speed pump
Coverage chart
0 U.S. g.p.m. 20 40 60
60
50
H 150
m
40
ft
30 100
1-2MXP
20
1-2MGP
50
10
0 0
0 m3/h 4 8 12 16
0 Q l/min 100 200
Operation Construction
BS 2F Pressure boosting sets with 2 fixed speed pump. - Automatic pressure boosting plant consisting of 1 to 3 horizontal multi-
Depending on the reduction of the pressure in the system, stage pumps complete with ball, non return valve on the suction side
the pressure switches determine the starting up of the pumps and ball valves on the delivery side.
in sequence and the microprocessor alternates the starts. Suction and delivery manifolds for boosting sets with 2,3 pumps:
- stainless steel AISI 304.
Connections are located on the delivery manifold for the installation of
vessels G1 connection.
BS1V1F Pressure boosting sets with 1 variable speed pump (with Applications
frequency converter into the control panel) and from 1 To supply water in civil and industrial buildings.
fixed speed pump As pressure boosting pump to increase water pressure when needed
According to the water consumption, one or more pumps (follow local rules).
start, one at variable speed and the others at fixed speed,
to grant the water quantity required at the set pressure. Motors
2-pole induction motors, 50 Hz, n ≈ 2900 rpm, suitable for operation with
frequency converter.
- Three-phase 230/400V ± 10% up to 3 kW;
BS2V Pressure boosting sets with two variable speed pumps 400/690V ± 10% for 4 kW to 7,5 kW;
(with frequency converter into the control panel). - Single-phase 230 V ± 10%, with thermal protector.
Depending on water consumption, one or more pumps are Insulation class F.
activated, all at variable speed, in order to guarantee the Protection IP 54.
quantity of water required at the set pressure. Constructed in accordance with: IEC 60034.
Other voltages and frequencies on request.
Vessels on request
When installing the unit, connect in the delivery section to a diaphragm
or galvanised tank.
The recommended sized are shown in the following page.
550
BS. 2MGP Systems with two Multi-Stage stainless steel pumps
Fixed speed pump or Variable speed pump (frequency converter)
Coverage chart
24 34
22 1-3MGP 202 1-3MGP 203
20 28
18
16 22
14
H m
H m
12 16
10
8 10
6
4 4
0 2
3 4 6 8 10 12 14 16 0 2 4 6 8 10 12 14 16
Q m /h Q m 3/h
45 60
40
1-3MGP 204 1-3MGP 205
50
35
30 40
25
H m
H m
20 30
15
20
10
5 10
0 2 4 6 8 10 12 14 16 18 0 Q m2 4 6 8 10 12 14 16 18
Q m 3/h 3
/h
24 35
1-3MGP 402 1-3MGP 403
20 30
16 25
H m
H m
12 20
8 15
4 10
0 Q m
2 3/h 4 6 8 10 12 14 16 18 20 22 0Q m
2 3/h 4 6 8 10 12 14 16 18 20 22
50 60
1-3MGP 404 1-3MGP 405
40 50
30 40
H m
H m
20 30
10 20
0 Q m
2 3/h 4 6 8 10 12 14 16 18 20 22 0Q m
23/h 4 6 8 10 12 14 16 18 20 22
551
BS. 2MGP Systems with two Multi-Stage stainless steel pumps
Fixed speed pump or Variable speed pump (frequency converter)
L2
DN 2
Hv
Hf
h2 DN 1
h1
4.93.315.MGP
m1
(1)
L1 B2
(1) Anti-vibration pads kit supplied loose as standard Hf= Fixed speed boosting sets
Hv= Variable speed boosting sets
BS2F BSM2F
Mains: 400V 3~ Mains: 230V 1~ Motor Q Vessel
3~ 1~ max* Pres. switch setting Connection mm
Motor: 400V 3~ Motor: 230V 1~ Weight Mem. Vessel
kW HP l/min bar bar DN1 DN2 H h1 h2 L1 L2 m1 B2 B kg litre litre
BS2F 2MGP 203 BSM2F 2MGPM 203 0,45+0,45 0,6+0,6 155 1,4÷2,6 1,0÷2,2 G2 G 11/2 840 151 206 793 355 41 24x2 100
BS2F 2MGP 204 BSM2F 2MGPM 204 0,55+0,55 0,75+0,75 160 2,0÷3,2 1,5÷2,7 G2 G 11/2 840 151 206 793 355 46 24x2 100
BS2F 2MGP 205/A BSM2F 2MGPM 205 0,75+0,75 1+1 160 3,0÷4,5 2,5÷4,0 G2 G 11/2 840 151 206 793 355 52 24x2 100
235 625 600
BS2F 2MGP 403 BSM2F 2MGPM 403 0,55+0,55 0,75+0,75 230 1,2÷2,4 0,9÷2,1 G2 G 11/2 840 151 206 793 355 46 24x2 100
BS2F 2MGP 404/A BSM2F 2MGPM 404 0,75+0,75 1+1 220 2,4÷3,6 2,0÷3,2 G2 G 11/2 840 151 206 793 355 48 80 200
BS2F 2MGP 405 BSM2F 2MGPM 405 1,1+1,1 1,5+1,5 220 3,0÷4,5 2,5÷4,0 G2 G 11/2 840 151 206 793 355 54 80 200
* Maximum pumps flow at minimum set pressure of 2 nd pressure switch.
BS1V1F BSM1V1F
Mains: 400V 3~ Mains: 230V 1~ Motor Connection mm Vessel
3~
Motor: 400V 3~ 1~
Motor: 230V 3~ and 230V 1~ Weight Membrane
kW HP DN1 DN2 H h1 h2 L1 L2 m1 B2 B kg litre
BS1V1F 2MGP 203 BSM1V1F 2MGP 203 0,45+0,45 0,6+0,6 G2 G 11/2 1100 151 206 793 355 41 24x2
BS1V1F 2MGP 204 BSM1V1F 2MGP 204 0,55+0,55 0,75+0,75 G2 G 11/2 1100 151 206 793 355 46 24x2
BS1V1F 2MGP 205/A BSM1V1F 2MGP 205 0,75+0,75 1+1 G2 G 11/2 1100 151 206 793 355 52 24x2
235 625 600
BS1V1F 2MGP 403 BSM1V1F 2MGP 403 0,55+0,55 0,75+0,75 G2 G 11/2 1100 151 206 793 355 46 24x2
BS1V1F 2MGP 404/A BSM1V1F 2MGP 404 0,75+0,75 1+1 G2 G 11/2 1100 151 206 793 355 48 24x2
BS1V1F 2MGP 405 BSM1V1F 2MGP 405 1,1+1,1 1,5+1,5 G2 G 11/2 1100 151 206 793 355 54 24x2
BS2V BSM2V
Mains: 400V 3~ Mains: 230V 1~ Motor Connection mm Vessel
3~
Motor: 400V 3~ 1~
Motor: 230V 3~ Weight Membrane
kW HP DN1 DN2 H h1 h2 L1 L2 m1 B2 B kg litre
BS2V 2MGP 203 BSM2V 2MGP 203 0,45+0,45 0,6+0,6 G2 G 11/2 1100 151 206 793 355 41 24x2
BS2V 2MGP 204 BSM2V 2MGP 204 0,55+0,55 0,75+0,75 G2 G 11/2 1100 151 206 793 355 46 24x2
BS2V 2MGP 205/A BSM2V 2MGP 205 0,75+0,75 1+1 G2 G 11/2 1100 151 206 793 355 52 24x2
235 625 600
BS2V 2MGP 403 BSM2V 2MGP 403 0,55+0,55 0,75+0,75 G2 G 11/2 1100 151 206 793 355 46 24x2
BS2V 2MGP 404/A BSM2V 2MGP 404 0,75+0,75 1+1 G2 G 11/2 1100 151 206 793 355 48 24x2
BS2V 2MGP 405 BSM2V 2MGP 405 1,1+1,1 1,5+1,5 G2 G 11/2 1100 151 206 793 355 54 24x2
Dimensions not binding to be verified when ordering
552
BS. MGP. EM Pressure boosting sets with 1 to 3 horizontal multi-stage
pumps with EASYMAT frequency converter
DN2
h2
H
DN1
h1
4.93.334.1
m1 B2
L2
L1
Mains: 1~
Aliment.: 1 ~230V
230 V Mains:
Aliment.:1~
1 ~230V
230 V Connection
P2 mm
Motor:
Motore:3~ 3 ~230V
230 V Motor:
Motore: 1~1 ~230V
230 V
mains
Aliment. motor
motore
A A A kW HP DN1 DN2 H h1 h2 L1 L2 m1 B B2
BSM1V 1MGP 202-EMT 2,1 1,7 BSM1V 1MGPM 202-EMM 2,3 0,33 0,45 516
BSM1V 1MGP 203-EMT 3,2 2,4 BSM1V 1MGPM 203-EMM 3 0,45 0,6 516
G1 G 1 691 116 535 269 95 200 146
BSM1V 1MGP 204-EMT 4 2,8 BSM1V 1MGPM 204-EMM 3,3 0,55 0,75 516
BSM1V 1MGP 205/A-EMT 5 3,5 BSM1V 1MGPM 205-EMM 5,4 0,75 1 545
BSM1V 1MGP 402-EMT 3,2 2,4 BSM1V 1MGPM 402-EMM 3 0,45 0,6 516
BSM1V 1MGP 403-EMT 4,3 3 BSM1V 1MGPM 403-EMM 3,5 0,55 0,75 516
G1 G 1 691 116 535 269 95 200 146
BSM1V 1MGP 404/A-EMT 5 3,5 BSM1V 1MGPM 404-EMM 5,4 0,75 1 545
BSM1V 1MGP 405-EMT 6,4 4,5 BSM1V 1MGPM 405-EMM 7 1,1 1,5 575
Dimensions not binding to be verified when ordering
553
BS. MGP. EM Pressure boosting sets with 1 to 3 horizontal multi-stage
pumps with EASYMAT frequency converter
DN2
h2
H
DN1
h1
(1) m1
B L2
B2 L1
Mains: 1~
Aliment.: 1 ~230V
230 V Connection mm
Motor:
Motore:3~ 3 ~230V
230 V P2
mains
Aliment. motor
motore
A A kW HP DN1 DN2 H h1 h2 L1 L2 m1 B B2
BSM2V 2MGP 202-EMT 2 x 2,1 2 x 1,7 2 x 0,33 2 x 0,45 566
BSM2V 2MGP 203-EMT 2 x 3,2 2 x 2,4 2 x 0,45 2 x 0,6 566
G 2 G 1 1/2 783 151 480 319 240 600 625
BSM2V 2MGP 204-EMT 2x4 2 x 2,8 2 x 0,55 2 x 0,75 566
BSM2V 2MGP 205/A-EMT 2x5 2 x 3,5 2 x 0,75 2 x 1 595
BSM2V 2MGP 402-EMT 2 x 3,2 2 x 2,4 2 x 0,45 2 x 0,6 566
BSM2V 2MGP 403-EMT 2 x 4,3 2x3 2 x 0,55 2 x 0,75 566
G 2 G 1 1/2 783 151 480 319 240 600 625
BSM2V 2MGP 404/A-EMT 2x5 2 x 3,5 2 x 0,75 2 x 1 595
BSM2V 2MGP 405-EMT 2 x 6,4 2 x 4,5 2 x 1,1 2 x 1,5 625
Dimensions not binding to be verified when ordering (1) Anti-vibration pads kit supplied loose as standard
DN2
h2
H
DN1
h1
(1)
m1
B L2
B2 L1
Mains:
Aliment.:1~
1 ~230V
230 V Connection mm
Motor:
Motore:3~ 3 ~230V
230 V P2
mains motor
Aliment. motore
A A kW HP DN1 DN2 H h1 h2 L1 L2 m1 B B2
BSM3V 3MGP 202-EMT 3 x 2,1 3 x 1,7 3 x 0,33 3 x 0,45 573
BSM3V 3MGP 203-EMT 3 x 3,2 3 x 2,4 3 x 0,45 3 x 0,6 573
G 2 1/2 G 2 805 167 486 326 305 950 1000
BSM3V 3MGP 204-EMT 3x4 3 x 2,8 3 x 0,55 3 x 0,75 573
BSM3V 3MGP 205/A-EMT 3x5 3 x 3,5 3 x 0,75 3x1 602
BSM3V 3MGP 402-EMT 3 x 3,2 3 x 2,4 3 x 0,45 3 x 0,6 573
BSM3V 3MGP 403-EMT 3 x 4,3 3x3 3 x 0,55 3 x 0,75 573
G 2 1/2 G 2 805 167 486 326 305 950 1000
BSM3V 3MGP 404/A-EMT 3x5 3 x 3,5 3 x 0,75 3x1 602
BSM3V 3MGP 405-EMT 3 x 6,4 3 x 4,5 3 x 1,1 3 x 1,5 632
Dimensions not binding to be verified when ordering (1) Anti-vibration pads kit supplied loose as standard
554
BS. 2MXP Systems with two Multi-Stage stainless steel pumps
Fixed speed pump or Variable speed pump (frequency converter)
Coverage chart
24 34
22 1-3MXP 202 1-3MXP 203
20 28
18
16 22
14
Hm
Hm
12 16
10
8 10
6
4 4
0 Q m 3/h 4 6 8 10 12 14 16 0 Q m 3/h 4 6 8 10 12 14 16
45 60
40 1-3MXP 204 1-3MXP 205
50
35
30 40
25
Hm
Hm
20 30
15
20
10
5 10
0 Q m 3/h 4 6 8 10 12 14 16 18 0 Q m 3/h 3 6 9 12 15 18
70 24
1-3MXP 206 1-3MXP 402
60 20
50
16
40
Hm
Hm
12
30
20 8
10 4
0 Q m 3/h 3 6 9 12 15 18 0 Q m 3/h 4 6 8 10 12 14 16 18 20 22
35 50
1-3MXP 403 1-3MXP 404
30
40
25
30
Hm
Hm
20
20
15
10 10
0 Q m 3/h 4 6 8 10 12 14 16 18 20 22 0 Q m 3/h 4 6 8 10 12 14 16 18 20 22
60 70
1-3MXP 405 1-3MXP 406
60
50
50
40
Hm
Hm
40
30
30
20 20
0 Q m 3/h 4 6 8 10 12 14 16 18 20 22 0 Q m 3/h 4 6 8 10 12 14 16 18 20 22
555
BS. 2MXP Systems with two Multi-Stage stainless steel pumps
Fixed speed pump or Variable speed pump (frequency converter)
L2
DN 2
Hv
Hf
DN 1
h2
h1
4.93.315
m1
(1)
L1 B2
(1) Anti-vibration pads kit supplied loose as standard Hf= Fixed speed boosting sets
Hv= Variable speed boosting sets
BS2F BSM2F
Mains: 400V 3~ Mains: 230V 1~ Motor Q Pres. switch setting Vessel
max* mm
Motor: 400V 3~ Motor: 230V 1~ Mem. Vessel
kW HP l/min bar bar DN1 DN2 Hf h1 h2 L1 L2 m1 B2 B kg litre litre
BS2F 2MXP 203 BSM2F 2MXPM 203 0,45+0,45 0,6+0,6 155 1,4÷2,6 1,0÷2,2 G2 G 11/2 857 151 191 729 319 41 24x2 100
BS2F 2MXP 204/A BSM2F 2MXPM 204/A 0,55+0,55 0,75+0,75 160 2,0÷3,2 1,5÷2,7 G2 G 11/2 857 151 191 729 319 46 24x2 100
BS2F 2MXP 205/A BSM2F 2MXPM 205 0,75+0,75 1+1 160 3,0÷4,5 2,5÷4,0 G2 G 11/2 857 151 191 729 319 48 24x2 100
BS2F 2MXP 206 BSM2F 2MXPM 206 0,75+0,75 1+1 160 3,7÷5,3 3,4÷5 G2 G 11/2 857 187 198 779 369 24x2 100
240 625 600
BS2F 2MXP 403/A BSM2F 2MXPM 403/A 0,55+0,55 0,75+0,75 230 1,5÷2,7 1,2÷2,4 G2 G 11/2 857 151 191 729 319 46 24x2 100
BS2F 2MXP 404/B BSM2F 2MXPM 404/A 0,75+0,75 1+1 220 2,4÷3,6 2,0÷3,2 G2 G 11/2 857 151 191 729 319 48 80 200
BS2F 2MXP 405 BSM2F 2MXPM 405 1,1+1,1 1,5+1,5 220 3,0÷4,5 3,5÷4,0 G2 G 11/2 857 151 191 729 319 54 80 200
BS2F 2MXP 406 BSM2F 2MXPM 406 1,1+1,1 1,5+1,5 220 3,8÷5,4 3,5÷5,1 G2 G 11/2 857 187 198 779 369 80 200
* Maximum pumps flow at minimum set pressure of 2 nd pressure switch.
BS1V1F BSM1V1F
Mains: 400V 3~ Mains: 230V 1~ Motor Connection Vessel
mm Weight Membrane
Motor: 400V 3~ Motor: 230V 3~ and 230V 1~ litre
kW HP DN1 DN2 Hf h1 h2 L1 L2 m1 B2 B kg
BS1V1F 2MXP 203 BSM1V1F 2MXP 203 0,45+0,45 0,6+0,6 G2 G 11/2 1349 257 206 814 319 41 24x2
BS1V1F 2MXP 204/A BSM1V1F 2MXP 204/A 0,55+0,55 0,75+0,75 G2 G 11/2 1349 257 206 814 319 46 24x2
BS1V1F 2MXP 205/A BSM1V1F 2MXP 205 0,75+0,75 1+1 G2 G 11/2 1349 257 206 814 319 48 24x2
BS1V1F 2MXP 206 BSM1V1F 2MXP 206 0,75+0,75 1+1 G2 G 11/2 1349 293 213 864 369 24x2
476 625 600
BS1V1F 2MXP 403/A BSM1V1F 2MXP 403/A 0,55+0,55 0,75+0,75 G2 G 11/2 1349 257 206 814 319 46 24x2
BS1V1F 2MXP 404/B BSM1V1F 2MXP 404/A 0,75+0,75 1+1 G2 G 11/2 1349 257 206 814 319 48 80
BS1V1F 2MXP 405 BSM1V1F 2MXP 405 1,1+1,1 1,5+1,5 G2 G 11/2 1349 257 206 814 319 54 80
BS1V1F 2MXP 406 BSM1V1F 2MXP 406 1,1+1,1 1,5+1,5 G2 G 11/2 1349 293 213 864 369 80
BS2V BSM2V
Mains: 400V 3~ Mains: 230V 1~ Motor Connection Vessel
mm Weight Membrane
Motor: 400V 3~ Motor: 230V 3~ litre
kW HP DN1 DN2 Hf h1 h2 L1 L2 m1 B2 B kg
BS2V 2MXP 203 BSM2V 2MXP 203 0,45+0,45 0,6+0,6 G2 G 11/2 1349 257 206 814 319 41 24x2
BS2V 2MXP 204/A BSM2V 2MXP 204/A 0,55+0,55 0,75+0,75 G2 G 11/2 1349 257 206 814 319 46 24x2
BS2V 2MXP 205/A BSM2V 2MXP 205 0,75+0,75 1+1 G2 G 11/2 1349 257 206 814 319 48 24x2
BS2V 2MXP 206 BSM2V 2MXP 206 0,75+0,75 1+1 G2 G 11/2 1349 293 213 864 369 24x2
476 625 600
BS2V 2MXP 403/A BSM2V 2MXP 403/A 0,55+0,55 0,75+0,75 G2 G 11/2 1349 257 206 814 319 46 24x2
BS2V 2MXP 404/B BSM2V 2MXP 404/A 0,75+0,75 1+1 G2 G 11/2 1349 257 206 814 319 48 80
BS2V 2MXP 405 BSM2V 2MXP 405 1,1+1,1 1,5+1,5 G2 G 11/2 1349 257 206 814 319 54 80
BS2V 2MXP 406 BSM2V 2MXP 406 1,1+1,1 1,5+1,5 G2 G 11/2 1349 293 213 814 369 80
556
BS. MXP. EM Pressure boosting sets with 1 to 3 horizontal multi-stage
pumps with EASYMAT frequency converter
DN2
h2
H
DN1
h1
4.93.334.1
m1 B2
L2
L1
Mains:
Aliment.:1~
1 ~230V
230 V Mains:
Aliment.:1~
1 ~230V
230 V Connection
P2 mm
Motor:
Motore: 3~3 ~230V
230 V Motor:
Motore: 1~1 ~230V
230 V
mains motore
Aliment. motor
A A A kW HP DN1 DN2 H h1 h2 L1 L2 m1 B B2
BSM1V 1MXP 202-EMT 2,1 1,7 BSM1V 1MXPM 202-EMM 2,3 0,33 0,45 516
BSM1V 1MXP 203-EMT 3,2 2,4 BSM1V 1MXPM 203-EMM 3 0,45 0,6 516
BSM1V 1MXP 204/A-EMT 4 2,8 BSM1V 1MXPM 204/A-EMM 3,3 0,55 0,75 G1 G1 701 116 545 545 269 95 200 146
BSM1V 1MXP 205/A-EMT 5 3,5 BSM1V 1MXPM 205-EMM 5,4 0,75 1 545
BSM1V 1MXP 206-EMT 5 3,5 BSM1V 1MXPM 206-EMM 5,4 0,75 1 G 1 1/4 G1 744 152 552 646 324 113 214 185
BSM1V 1MXP 402-EMT 3,2 2,4 BSM1V 1MXPM 402-EMM 3 0,45 0,6 516
BSM1V 1MXP 403/A-EMT 4,3 3 BSM1V 1MXPM 403/A-EMM 3,5 0,55 0,75 G1 G1 701 116 545 545 269 95 200 146
BSM1V 1MXP 404/B-EMT 5 3,5 BSM1V 1MXPM 404/A-EMM 5,4 0,75 1 545
BSM1V 1MXP 405-EMT 6,4 4,5 BSM1V 1MXPM 405-EMM 7 1,1 1,5 575
BSM1V 1MXP 406-EMT 10,8 7,5 BSM1V 1MXPM 406-EMM 9,2 1,5 2 G 1 1/4 G1 744 152 552 673 324 113 214 185
557
BS. MXP. EM Pressure boosting sets with 1 to 3 horizontal multi-stage
pumps with EASYMAT frequency converter
DN2
h2
H
DN1
h1
(1)
m1
B L2
B2 L1
Mains: 1~
Aliment.: 1 ~230V
230 V Connection mm
P2
Motor:
Motore:3~ 3 ~230V
230 V
Aliment.
mains motore
motor
A A kW HP DN1 DN2 H h1 h2 L1 L2 m1 B B2
BSM2V 2MXP 202-EMT 2 x 2,1 2 x 1,7 2 x 0,33 2 x 0,45 566
BSM2V 2MXP 203-EMT 2 x 3,2 2 x 2,4 2 x 0,45 2 x 0,6 566
BSM2V 2MXP 204/A-EMT 2x4 2 x 2,8 2 x 0,55 2 x 0,75 G2 G 1 1/2 793 151 490 595 319 240 600 625
BSM2V 2MXP 205/A-EMT 2x5 2 x 3,5 2 x 0,75 2x1 595
BSM2V 2MXP 206-EMT 2x5 2 x 3,5 2 x 0,75 2x1 836 187 497 691 369
BSM2V 2MXP 402-EMT 2 x 3,2 2 x 2,4 2 x 0,45 2 x 0,6 566
BSM2V 2MXP 403/A-EMT 2 x 4,3 2x3 2 x 0,55 2 x 0,75 595
BSM2V 2MXP 404/B-EMT 2x5 2 x 3,5 2 x 0,75 2x1 G2 G 1 1/2 793 151 490 595 319 240 600 625
BSM2V 2MXP 405-EMT 2 x 6,4 2 x 4,5 2 x 1,1 2 x 1,5 625
BSM2V 2MXP 406-EMT 2 x 10,8 2 x 7,5 2 x 1,5 2x2 836 187 497 718 369
Dimensions not binding to be verified when ordering (1) Anti-vibration pads kit supplied loose as standard
DN2
h2
H
DN1
h1
(1)
m1
B L2
B2 L1
Mains: 1~
Aliment.: 1 ~230V
230 V Connection mm
Motor:
Motore:3~ 3 ~230V
230 V P2
mains motor
Aliment. motore
A A kW HP DN1 DN2 H h1 h2 L1 L2 m1 B B2
BSM3V 3MXP 202-EMT 3 x 2,1 3 x 1,7 3 x 0,33 3 x 0,45 573
BSM3V 3MXP 203-EMT 3 x 3,2 3 x 2,4 3 x 0,45 3 x 0,6 573
BSM3V 3MXP 204/A-EMT 3x4 3 x 2,8 3 x 0,55 3 x 0,75 G 2 1/2 G2 815 167 496 602 326 305 950 1000
BSM3V 3MXP 205/A-EMT 3x5 3 x 3,5 3 x 0,75 3x1 602
BSM3V 3MXP 206-EMT 3x5 3 x 3,5 3 x 0,75 3x1 858 203 503 699 377
BSM3V 3MXP 402-EMT 3 x 3,2 3 x 2,4 3 x 0,45 3 x 0,6 573
BSM3V 3MXP 403/A-EMT 3 x 4,3 3x3 3 x 0,55 3 x 0,75 602
BSM3V 3MXP 404/B-EMT 3x5 3 x 3,5 3 x 0,75 3x1 G 2 1/2 G2 815 167 496 602 326 305 950 1000
BSM3V 3MXP 405-EMT 3 x 6,4 3 x 4,5 3 x 1,1 3 x 1,5 632
BSM3V 3MXP 406-EMT 3 x 10,8 3 x 7,5 3 x 1,5 3x2 858 203 503 726 377
Dimensions not binding to be verified when ordering (1) Anti-vibration pads kit supplied loose as standard
558
BS. MPSU Pressure boosting sets with 1 to 3 Vertical Multi-Stage Pumps
Fixed speed pump or Variable speed pump (frequency converter)
Coverage chart
0 Imp g.p.m. 30 60
80
250
H
70
m
60 200
ft
50
150
40 1-3MPSU
30 100
20
50
10 3
0 m /h 6 12 18 24
0 Q l/min 150 300
Operation Construction
BS 1-6F Pressure boosting sets with 1 to 6 fixed speed pump. - Automatic pressure boosting plant consisting of 1 to 6 vertical multi-
Sets with 4,5 and 6 pumps on request. stage close coupled pumps complete with ball, non return valve on the
Depending on the reduction of the pressure in the system, suction side and ball valves on the delivery side.
the pressure switches (pressure transducer for 3-pump sets)
determine the starting up of the pumps in sequence and the Suction and delivery manifolds for boosting sets with 2,3 pumps:
microprocessor alternates the starts. - stainless steel AISI 304.
Connections are located on the delivery manifold for the installation of
vessels G1 connection.
Applications
BS1V2-5F Pressure boosting sets with 1 variable speed pump (with To supply water in civil and industrial buildings.
frequency converter into the control panel) and from 1 to 5 As pressure boosting pump to increase water pressure when needed
fixed speed pumps (follow local rules).
Sets with 4,5 and 6 pumps on request.
According to the water consumption, one or more pumps Motors
start, one at variable speed and the others at fixed speed, 2-pole induction motors, 50 Hz, n ≈ 2900 rpm, suitable for operation with
to grant the water quantity required at the set pressure. frequency converter.
- Three-phase 230V - 400V ± 10%;
- Single-phase 230 V ± 10%.
Insulation class F.
BS1-6V Pressure boosting sets with 1 to 6 variable speed pumps Protection IP 68.
(with frequency converter into the control panel). Constructed in accordance with: IEC 60034.
Other voltages and frequencies on request.
Sets with 4,5 and 6 pumps on request.
Depending on water consumption, one or more pumps are
activated, all at variable speed, in order to guarantee the
Vessels on request
When installing the unit, connect in the delivery section to a diaphragm
quantity of water required at the set pressure.
or galvanised tank.
The recommended sized are shown in the following page.
559
BS. MPSU Pressure boosting sets with 1 to 3 Vertical Multi-Stage Pumps
Fixed speed pump or Variable speed pump (frequency converter)
Coverage chart
45 55
1-3MPSU 304 50 1-3MPSU 305
40
45
35
40
30 35
H m
H m
30
25
25
20
20
15 15
0 5 10 15 0 5 10 15
Q m 3/h Q m 3/h
70 80
1-3MPSU 306 1-3MPSU 307
60 70
60
50
50
H m
H m
40
40
30
30
20 20
0 5 10 15 0 Q m 3/h 5 10 15
Q m 3/h
45 55
40
1-3MPSU 504 50 1-3MPSU 505
45
35
40
30 35
H m
H m
25 30
25
20
20
15
15
10 10
0 5 10 15 20 25 0 Q m 3/h 5 10 15 20 25
Q m 3/h
70 80
1-3MPSU 506 1-3MPSU 507
60 70
50 60
40 50
H m
H m
30 40
20 30
10 20
0 Q m 3/h 5 10 15 20 25 0 Q m 3/h 5 10 15 20 25
560
BS. MPSU Pressure boosting sets with 1 to 3 Vertical Multi-Stage Pumps
Fixed speed pump or Variable speed pump (frequency converter)
Performance
BS1F BSM1F
Mains: 400V 3~ Mains: 230V 1~ Motor Pres. switch 1 Vessel Vessel
Motor: 400V 3~ Motor: 230V 1~ bar Membrane
kW HP min max litre litre
BS1F 1MPSU 304 BSM1F 1MPSUM 304 0,55 0,75 2,3 3,8 40 100
BS1F 1MPSU 305 BSM1F 1MPSUM 305 0,75 1 3 4,5 40 100
BS1F 1MPSU 306 BSM1F 1MPSUM 306 0,9 1,2 3,8 5,8 50 100
BS1F 1MPSU 307 BSM1F 1MPSUM 307 0,9 1,2 4,7 6,4 50 100
BS1F 1MPSU 504 BSM1F 1MPSUM 504 0,9 1,2 2,1 3,6 60 100
BS1F 1MPSU 505 BSM1F 1MPSUM 505 1,1 1,5 3 4,5 80 200
BS1F 1MPSU 506 BSM1F 1MPSUM 506 1,1 1,5 4,3 6 150 200
BS1F 1MPSU 507 BSM1F 1MPSUM 507 1,5 2 5,3 7,1 150 200
BS2F BSM2F
Mains: 400V 3~ Alimentazione 230V 1~ Motor Pres. switch 1 Pres. switch 2 Vessel Vessel
Motor: 400V 3~ Motore 230V 1~ bar bar Membrane
kW HP min max min max litre litre
BS2F 2MPSU 304 BSM2F 2MPSUM 304 0,55 x2 0,75 x2 2,3 3,8 1,8 3,3 40 100
BS2F 2MPSU 305 BSM2F 2MPSUM 305 0,75 x2 1 x2 3 4,5 2,5 4 40 100
BS2F 2MPSU 306 BSM2F 2MPSUM 306 0,9 x2 1,2 x2 3,8 5,8 3,5 5,5 50 100
BS2F 2MPSU 307 BSM2F 2MPSUM 307 0,9 x2 1,2 x2 4,7 6,4 4,4 6,1 50 100
BS2F 2MPSU 504 BSM2F 2MPSUM 504 0,9 x2 1,2 x2 2,1 3,6 1,7 3,2 60 100
BS2F 2MPSU 505 BSM2F 2MPSUM 505 1,1 x2 1,5 x2 3 4,5 2,5 4 80 200
BS2F 2MPSU 506 BSM2F 2MPSUM 506 1,1 x2 1,5 x2 4,3 6 4,1 5,7 150 200
BS2F 2MPSU 507 BSM2F 2MPSUM 507 1,5 x2 2 x2 5,3 7,1 5 6,8 150 200
BS3F
Mains: 400V 3~ Motor Pressure transducer Vessel Vessel
Motor: 400V 3~ bar Membrane
kW HP min max litre litre
BS3F 3MPSU 304 0,55 x3 0,75 x3 1,8 2,6 24x2 100
BS3F 3MPSU 305 0,75 x3 1 x3 2,3 3,1 24x2 100
BS3F 3MPSU 306 0,9 x3 1,2 x3 3 3,9 24x2 100
BS3F 3MPSU 307 0,9 x3 1,2 x3 2,9 4,4 24x2 100
BS3F 3MPSU 504 0,9 x3 1,2 x3 2,7 3,5 150 200
BS3F 3MPSU 505 1,1 x3 1,5 x3 3,4 4,3 150 200
BS3F 3MPSU 506 1,1 x3 1,5 x3 3,6 5,2 150 200
BS3F 3MPSU 507 1,5 x3 2 x3 4,6 6,3 150 200
561
BS. MPSU Pressure boosting sets with 1 to 3 Vertical Multi-Stage Pumps
Fixed speed pump or Variable speed pump (frequency converter)
DN 2
Hf
Hv
h2
DN1
h1
(1)
L1 m1
Connection
Collettori weight
TYPE TYPE mm Peso
DN 1 DN 2 Hf Hv h1 h2 L1 m1 kg
BS1. 1MPSU 304 BSM1. 1MPSUM 304 619 -
BS1. 1MPSU 305 BSM1. 1MPSUM 305 668
BS1. 1MPSU 306 BSM1. 1MPSUM 306 692
BS1. 1MPSU 307 BSM1. 1MPSUM 307 716
G 1 1/4 G 1 1/4 875 1045 94 625 365
BS1. 1MPSU 504 BSM1. 1MPSUM 504 644
BS1. 1MPSU 505 BSM1. 1MPSUM 505 668
BS1. 1MPSU 506 BSM1. 1MPSUM 506 737
BS1. 1MPSU 507 BSM1. 1MPSUM 507 786
Dimensions not binding to be verified when ordering (1) Anti-vibration pads kit supplied loose as standard
Hf= Fixed speed boosting sets
Hv= Variable speed boosting sets
L2
h2 Hf
Hv
h1
4.93.234.4
(1)
m1 B
L1f
L1v B2
Connection
Collettori mm weight
TYPE TYPE Peso
DN 1 DN 2 Hf Hv h1 h2 L1f L1v L2 m1 B B2 kg
BS.. 2MPSU 304 BSM.. 2MPSUM 304 629 50 - 50
BS.. 2MPSU 305 BSM.. 2MPSUM 305 698 52 - 52
BS.. 2MPSU 306 BSM.. 2MPSUM 306 722 54 - 55
BS.. 2MPSU 307 BSM.. 2MPSUM 307 746 56 - 58
G2 G2 865 1135 84 690 740 320 240 600 625
BS.. 2MPSU 504 BSM.. 2MPSUM 504 674 52 - 52
BS.. 2MPSU 505 BSM.. 2MPSUM 505 698 54 - 54
BS.. 2MPSU 506 BSM.. 2MPSUM 506 767 56 - 57
BS.. 2MPSU 507 BSM.. 2MPSUM 507 816 58 - 60
Dimensions not binding to be verified when ordering (1) Anti-vibration pads kit supplied loose as standard
562
BS. MPSU Pressure boosting sets with 1 to 3 Vertical Multi-Stage Pumps
Fixed speed pump or Variable speed pump (frequency converter)
L2
Hf
Hv
h2
h1
4.93.234.6
(1)
B
m1
L1f
L1v B2
Connection
Collettori mm weight
TYPE Peso
DN 1 DN 2 Hf Hv h1 h2 L1f L1v L2 m1 B B2 kg
BS.. 3MPSU 304 636 85
BS.. 3MPSU 305 705 88
BS.. 3MPSU 306 729 91
BS.. 3MPSU 307 753 94
G 2 1/2 G2 1090 1260 105 735 805 329 406 950 1000
BS.. 3MPSU 504 681 87
BS.. 3MPSU 505 705 90
BS.. 3MPSU 506 774 93
BS.. 3MPSU 507 823 96
Dimensions not binding to be verified when ordering (1) Anti-vibration pads kit supplied loose as standard
563
BS. MPSU. EM Pressure boosting sets with 1 to 3 vertical multi-stage
pumps with EASYMAT frequency converter
DN2
made in italy
H
h2
DN1
m1 B2
h1
L2
L1
Mains:
Aliment.:1~ 230V
1 ~ 230 V Mains: 1~ 230V
Aliment.: 1 ~ 230 V Connection mm
3 ~ 230 V
Motore: 3~ 230V
Motor: 1 ~ 230 V
Motore:1~ 230V
Motor: P2
mains motore
aliment. motor
A A A kW HP DN1 DN2 H h1 h2 L1 L2 m1 B2
BSM1V 1MPSU 304-EMT 3,9 2,8 BSM1V 1MPSUM 304-EMM 4,1 0,55 0,75 1055 952
BSM1V 1MPSU 305-EMT 4,7 3,3 BSM1V 1MPSUM 305-EMM 5 0,75 1 1124 1021
G 1 1/4 1 1/4 50 376 286 180 205
BSM1V 1MPSU 306-EMT 5,4 3,8 BSM1V 1MPSUM 306-EMM 6 0,9 1,2 1148 1045
BSM1V 1MPSU 307-EMT 6,4 4,5 BSM1V 1MPSUM 307-EMM 6,6 0,9 1,2 1172 1069
BSM1V 1MPSU 504-EMT 6,4 3,8 BSM1V 1MPSUM 504-EMM 6 0,9 1,2 1100 997
BSM1V 1MPSU 505-EMT 6,4 4,5 BSM1V 1MPSUM 505-EMM 7 1,1 1,5 1124 1021
G 1 1/4 G 1 1/4 50 376 286 180 205
BSM1V 1MPSU 506-EMT 6,9 4,8 1,1 1,5 1193 1090
BSM1V 1MPSU 507-EMT 9,7 6,8 1,5 2 1142 1139
Dimensions not binding to be verified when ordering
564
BS. MPSU. EM Pressure boosting sets with 1 to 3 vertical multi-stage
pumps with EASYMAT frequency converter
DN2
h2
H
made in italy made in italy
DN1
h1
(1) 4.93.335.2
m1 B
L2
B2
L1
Aliment.:
Mains: ~ 230 V
1~1 230V Connection mm
~ 230 V
Motore:3~3 230V P2
Motor: mains motor
aliment. motore
A A kW HP DN1 DN2 H h1 h2 L1 L2 m1 B B2
BSM2V 2MPSU 304-EMT 2 x 3,9 2 x 2,8 2 x 0,55 2 x 0,75 1130 932
BSM2V 2MPSU 305-EMT 2 x 4,7 2 x 3,3 2 x 0,75 2x1 1199 1001
G2 G2 84 420 320 240 600 625
BSM2V 2MPSU 306-EMT 2 x 5,4 2 x 3,8 2 x 0,9 2 x 1,2 1223 1025
BSM2V 2MPSU 307-EMT 2 x 6,4 2 x 4,5 2 x 0,9 2 x 1,2 1247 1049
BSM2V 2MPSU 504-EMT 2 x 6,4 2 x 3,8 2 x 0,9 2 x 1,2 1175 977
BSM2V 2MPSU 505-EMT 2 x 6,4 2 x 4,5 2 x 1,1 2 x 1,5 1199 1001
G2 G2 84 420 320 240 600 625
BSM2V 2MPSU 506-EMT 2 x 6,9 2 x 4,8 2 x 1,1 2 x 1,5 1268 1070
BSM2V 2MPSU 507-EMT 2 x 9,7 2 x 6,8 2 x 1,5 2x2 1317 1119
Dimensions not binding to be verified when ordering (1) Anti-vibration pads kit supplied loose as standard
DN2
h2
H
DN1
h1
(1) 4.93.335.2
m1 B
L2
B2
L1
Aliment.:
Mains: ~ 230 V
1~1 230V Connection mm
~ 230 V
Motore:3~3 230V P2
Motor: mains motore
aliment. motor
A A kW HP DN1 DN2 H h1 h2 L1 L2 m1 B B2
BSM3V 3MPSU 304-EMT 3 x 3,9 3 x 2,8 3 x 0,55 3 x 0,75 1151 953
BSM3V 3MPSU 305-EMT 3 x 4,7 3 x 3,3 3 x 0,75 3x1 1120 1022
G 2 1/2 G2 105 566 329 406 950 1000
BSM3V 3MPSU 306-EMT 3 x 5,4 3 x 3,8 3 x 0,9 3 x 1,2 1244 1046
BSM3V 3MPSU 307-EMT 3 x 6,4 3 x 4,5 3 x 0,9 3 x 1,2 1268 1070
BSM3V 3MPSU 504-EMT 3 x 6,4 3 x 3,8 3 x 0,9 3 x 1,2 1196 998
BSM3V 3MPSU 505-EMT 3 x 6,4 3 x 4,5 3 x 1,1 3 x 1,5 1220 1022
G 2 1/2 G2 105 566 329 406 950 1000
BSM3V 3MPSU 506-EMT 3 x 6,9 3 x 4,8 3 x 1,1 3 x 1,5 1286 1091
BSM3V 3MPSU 507-EMT 3 x 9,7 3 x 6,8 3 x 1,5 3x2 1338 1140
Dimensions not binding to be verified when ordering (1) Anti-vibration pads kit supplied loose as standard
565
BS. MXV-B Pressure boosting sets with 1 to 3 Vertical Multi-Stage Pumps
Fixed speed pump or Variable speed pump (frequency converter)
Coverage chart
100
300
H
m 200
1-3 MXV-B
50
H
40
ft
30 100
20
15 50
1 m3/h 2 3 4 5 10 20 30 40 50
Q
20 l/min 30 40 50 100 150 200 300 400 500
72.1002/1
Operation Construction
BS 1-6F Pressure boosting sets with 1 to 6 fixed speed pump. - Automatic pressure boosting plant consisting of 1 to 6 vertical multi-
Sets with 4,5 and 6 pumps on request. stage pumps complete with ball, non return valve on the suction side
Depending on the reduction of the pressure in the system, and ball valves on the delivery side.
the pressure switches (pressure transducer for 3-pump sets) Suction and delivery manifolds for boosting sets with 2,3 pumps:
determine the starting up of the pumps in sequence and the - stainless steel AISI 304.
microprocessor alternates the starts. Connections are located on the delivery manifold for the installation of
vessels G1 connection.
BS2-3V Pressure boosting sets with 2 to 3 variable speed pumps Electrical control boards:
(with I-MAT). - with microprocessor for fixed speed pump units. Motor starting is D.O.L.
Depending on water consumption, one or more pumps are - with frequency converter for variable speed pump units.
activated, all at variable speed, in order to guarantee the
quantity of water required at the set pressure. The unit includes one pressure gauge and three adjustable differential
pressure switches or pressure transducer.
Vessels on request
BS1-6V Pressure boosting sets with 1 to 6 variable speed pumps When installing the unit, connect in the delivery section to a diaphragm
(with frequency converter into the control panel). or galvanised tank.
Sets with 4,5 and 6 pumps on request. The recommended sized are shown in the following page.
Depending on water consumption, one or more pumps are
activated, all at variable speed, in order to guarantee the Special features on request
quantity of water required at the set pressure. Pressure boosting sets with 4,5 and 6 pumps.
566
BS. MXV-B Pressure boosting sets with 1 to 3 Vertical Multi-Stage Pumps
Fixed speed pump or Variable speed pump (frequency converter)
Coverage chart
1-3MXV-B 25 400
1-3MXV-B 32 400
120 120
100 100
300 300
80 10 H 80 10 H
ft ft
H H
m m
8 8
60 200 60 200
7 7
6 6
40 5 40 5
4 100 4 100
20 20
0 0 0 0
0 m 3/h 3 6 9 12 15 0 m3/h 6 12 18 24 27
0 Q l/min 50 100 150 200 250 0 Q l/min 100 200 300 400
72.951.1C 72.951.2C
0 U.S. g.p.m. 40 60 80 100 120 140 160 180 0 U.S. g.p.m. 100 200 300
0 Imp. g.p.m. 40 60 80 100 120 140 0 Imp. g.p.m. 100 150 200 250
140 140
ft
100 100
10
10 300 300
9
80 H 80
8 ft
H 8
m
7 H 7
200 m 200
60
6
6
ft
5 5
40 40
4 4
100 100
3
20 20
0 0 0 0
0 15 30 45 60 75
Q m /h 300
3
0 6 12 18 24 30 36 42
Qm /h
3
0 l/min 200 300 400 500 600 700 0 l/min 600 900 1200
72.951.3C 72.953.1C
567
BS. MXV-B Pressure boosting sets with 1 to 3 Vertical Multi-Stage Pumps
Fixed speed pump or Variable speed pump (frequency converter)
Performance
BS1F BSM1F
Mains: 400V 3~ Mains: 230V 1~ Motor Pres. switch 1 Vessel Vessel
Motor: 400V 3~ Motor: 230V 1~ bar Membrane
kW HP min max litre litre
BS1F 1MXV-B 25-204 BSM1F 1MXV-BM 25-204 0,75 1 2,5 4 40 100
BS1F 1MXV-B 25-205 BSM1F 1MXV-BM 25-205 0,75 1 3,5 5 50 100
BS1F 1MXV-B 25-206 BSM1F 1MXV-BM 25-206 1,1 1,5 4 6 50 100
BS1F 1MXV-B 25-207 BSM1F 1MXV-BM 25-207 1,1 1,5 5 7 50 100
BS1F 1MXV-B 25-208 BSM1F 1MXV-BM 25-208 1,5 2 6 8 60 100
BS1F 1MXV-B 25-210 BSM1F 1MXV-BM 25-210 1,5 2 6,5 9,5 60 100
BS1F 1MXV-B 32-404 BSM1F 1MXV-BM 32-404 1,1 1,5 2,3 3,8 80 100
BS1F 1MXV-B 32-405 BSM1F 1MXV-BM 32-405 1,1 1,5 3,4 4,9 100 100
BS1F 1MXV-B 32-406 BSM1F 1MXV-BM 32-406 1,5 2 4 6 100 100
BS1F 1MXV-B 32-407 BSM1F 1MXV-BM 32-407 1,5 2 5 7 100 300
BS1F 1MXV-B 32-408/A 2,2 3 6 8 150 300
BS1F 1MXV-B 32-410/A 2,2 3 6,5 9,5 150 300
BS1F 1MXV-B 40-804 BSM1F 1MXV-BM 40-804 1,5 2 2,5 4 200 300
BS1F 1MXV-B 40-805/A 2,2 3 3,5 5 300 500
BS1F 1MXV-B 40-806/A 2,2 3 4 6 300 500
BS1F 1MXV-B 40-807/A 3 4 5 7 300 500
BS1F 1MXV-B 40-808/A 3 4 6 8 300 500
BS1F 1MXV-B 40-810/A 3,7 5 7,5 10,5 500 800
BS2F BSM2F
Mains: 400V 3~ Mains: 230V 1~ Motor Pres. switch 1 Pres. switch 2 Vessel Vessel
Motor: 400V 3~ Motor: 230V 1~ bar bar Membrane
kW HP min max min max litre litre
BS2F 2MXV-B 25-204 BSM2F 2MXV-BM 25-204 0,75 x2 1 x2 2,5 4 2,2 3,7 40 100
BS2F 2MXV-B 25-205 BSM2F 2MXV-BM 25-205 0,75 x2 1 x2 3,5 5 3 4,5 50 100
BS2F 2MXV-B 25-206 BSM2F 2MXV-BM 25-206 1,1 x2 1,5 x2 4 6 3,5 5,5 50 100
BS2F 2MXV-B 25-207 BSM2F 2MXV-BM 25-207 1,1 x2 1,5 x2 5 7 4,5 6,5 50 100
BS2F 2MXV-B 25-208 BSM2F 2MXV-BM 25-208 1,5 x2 2 x2 6 8 5,5 7,5 60 100
BS2F 2MXV-B 25-210 BSM2F 2MXV-BM 25-210 1,5 x2 2 x2 6,5 9,5 6 9 60 100
BS2F 2MXV-B 32-404 BSM2F 2MXV-BM 32-404 1,1 x2 1,5 x2 2,3 3,8 1,8 3,3 80 100
BS2F 2MXV-B 32-405 BSM2F 2MXV-BM 32-405 1,1 x2 1,5 x2 3,4 4,9 3 4,5 100 100
BS2F 2MXV-B 32-406 BSM2F 2MXV-BM 32-406 1,5 x2 2 x2 4 6 3,5 5,5 100 100
BS2F 2MXV-B 32-407 BSM2F 2MXV-BM 32-407 1,5 x2 2 x2 5 7 4,5 6,5 100 300
BS2F 2MXV-B 32-408/A 2,2 x2 3 x2 6 8 5,5 7,5 150 300
BS2F 2MXV-B 32-410/A 2,2 x2 3 x2 6,5 9,5 6 9 150 300
BS2F 2MXV-B 40-804 BSM2F 2MXV-BM 40-804 1,5 x2 2 x2 2,5 4 2,2 3,7 200 300
BS2F 2MXV-B 40-805/A 2,2 x2 3 x2 3,5 5 3 4,5 300 500
BS2F 2MXV-B 40-806/A 2,2 x2 3 x2 4 6 3,5 5,5 300 500
BS2F 2MXV-B 40-807/A 3 x2 4 x2 5 7 4,5 6,5 300 500
BS2F 2MXV-B 40-808/A 3 x2 4 x2 6 8 5,5 7,5 300 500
BS2F 2MXV-B 40-810/A 3,7 x2 5 x2 8 10 7,5 9,5 500 800
568
BS. MXV-B Pressure boosting sets with 1 to 3 Vertical Multi-Stage Pumps
Fixed speed pump or Variable speed pump (frequency converter)
Performance
BS3F
Mains: 400V 3~ Motor Pressure transducer Vessel Vessel
Motor: 400V 3~ bar Membrane
kW HP min max litre litre
BS3F 3MXV-B 25-204 0,75 x3 1 x3 3 3,9 24x2 100
BS3F 3MXV-B 25-205 0,75 x3 1 x3 3,3 4,8 24x2 100
BS3F 3MXV-B 25-206 1,1 x3 1,5 x3 4,1 5,8 24x2 100
BS3F 3MXV-B 25-207 1,1 x3 1,5 x3 5 6,7 24x2 100
BS3F 3MXV-B 25-208 1,5 x3 2 x3 5,8 7,7 60 100
BS3F 3MXV-B 25-210 1,5 x3 2 x3 7,5 9,7 80 100
BS3F 3MXV-B 32-404 1,1 x3 1,5 x3 3 3,8 100 200
BS3F 3MXV-B 32-405 1,1 x3 1,5 x3 3,2 4,7 100 200
BS3F 3MXV-B 32-406 1,5 x3 2 x3 4 5,6 100 200
BS3F 3MXV-B 32-407 1,5 x3 2 x3 4,8 6,6 150 200
BS3F 3MXV-B 32-408/A 2,2 x3 3 x3 5,7 7,6 150 300
BS3F 3MXV-B 32-410/A 2,2 x3 3 x3 7,4 9,5 200 300
BS3F 3MXV-B 40-804 1,5 x3 2 x3 3 3,9 300 500
BS3F 3MXV-B 40-805/A 2,2 x3 3 x3 3,4 4,9 300 500
BS3F 3MXV-B 40-806/A 2,2 x3 3 x3 4,2 5,9 300 500
BS2F 3MXV-B 40-807/A 3 x3 4 x3 5,1 6,9 300 500
BS2F 3MXV-B 40-808/A 3 x3 4 x3 6 7,9 300 500
BS2F 3MXV-B 40-810/A 3,7 x3 5 x3 7,8 9,9 500 800
569
BS. MXV-B Pressure boosting sets with 1 to 3 Vertical Multi-Stage Pumps
Fixed speed pump or Variable speed pump (frequency converter)
Performance
1 2 3 4 5 6 kW HP 2 3 kW HP
MXV-B 25-204 0,75 1 MXV-B 25-203-ITT 0,75 1
MXV-B 25-205 0,75 1 MXV-B 25-204-ITT 0,75 1
MXV-B 25-206 1,1 1,5 MXV-B 25-205-ITT 0,75 1
MXV-B 25-207 1,1 1,5 MXV-B 25-206/A-ITT 1,1 1,5
MXV-B 25-208 1,5 2 MXV-B 25-207/A-ITT 1,1 1,5
MXV-B 25-210 1,5 2 MXV-B 25-208/A-ITT 1,5 2
MXV-B 32-404 1,1 1,5 MXV-B 25-210/A-ITT 1,5 2
BS1V BS2V BS3V BS4V BS5V BS6V MXV-B 32-405 1,1 1,5 BS2V BS3V MXV-B 32-403-ITT 0,75 1
BS1V1F BS1V2F BS1V3F BS1V4F BS1V5F MXV-B 32-406 1,5 2 -ITT -ITT MXV-B 32-404/A-ITT 1,1 1,5
BSM1V1F* MXV-B 32-407 1,5 2 MXV-B 32-405/A-ITT 1,1 1,5
BSM2V** MXV-B 32-408/A 2,2 3 MXV-B 32-406/A-ITT 1,5 2
MXV-B 32-410/A 2,2 3 MXV-B 32-407/A-ITT 1,5 2
MXV-B 40-804 1,5 2 MXV-B 32-408/B-ITT 2,2 3
MXV-B 40-805/A 2,2 3 MXV-B 32-410/B-ITT 2,2 3
MXV-B 40-806/A 2,2 3 MXV-B 40-803/A-ITT 1,1 1,5
MXV-B 40-807/A 3 4 MXV-B 40-804/A-ITT 1,5 2
MXV-B 40-808/A 3 4 MXV-B 40-805/B-ITT 2,2 3
MXV-B 40-810/A 3,7 5 MXV-B 40-806/B-ITT 2,2 3
MXV-B 40-807/A-ITT 3 4
MXV-B 40-808/A-ITT 3 4
MXV-B 40-810/B-ITT 3,7 5
570
BS. MXV-B Pressure boosting sets with 1 to 3 Vertical Multi-Stage Pumps
Fixed speed pump or Variable speed pump (frequency converter)
h7
DN1 DN 2
h3
n4 l7v-l7f m7 m4
(1) fgv-fgf l6
Connection
Collettori mm
TYPE TYPE
DN 1 DN 2 h9f h9v h7 h3 m4 m7 l6 n4 fgf fgv l7f l7v
BS1. 1MXV-B 25-204 BSM1. 1MXV-BM 25-204 609
BS1. 1MXV-B 25-205 BSM1. 1MXV-BM 25-205 632
BS1. 1MXV-B 25-206 BSM1. 1MXV-BM 25-206 656
BS1. 1MXV-B 25-207 BSM1. 1MXV-BM 25-207 G1 G1 1065 1345 680 120 625 140 * 365 * 410 * 45
BS1. 1MXV-B 25-208 BSM1. 1MXV-BM 25-208 704
BS1. 1MXV-B 25-210 BSM1. 1MXV-BM 25-210 752
BS1. 1MXV-B 32-404 BSM1. 1MXV-BM 32-404 609
BS1. 1MXV-B 32-405 BSM1. 1MXV-BM 32-405 632
BS1. 1MXV-B 32-406 BSM1. 1MXV-BM 32-406 G 1 1/4 G 1 1/4 1065 1345 656 120 625 175 * 365 * 410 * 45
BS1. 1MXV-B 32-407 BSM1. 1MXV-BM 32-407 680
BS1. 1MXV-B 32-408/A 744
BS1. 1MXV-B 32-410/A 792
BS1. 1MXV-B 40-804 BSM1. 1MXV-BM 40-804 637
BS1. 1MXV-B 40-805/A 707
BS1. 1MXV-B 40-806/A G 1 1/2 G 1 1/2 1065 1345 737 125 625 213 * 365 * 410 * 45
BS1. 1MXV-B 40-807/A 790
BS1. 1MXV-B 40-808/A 820
BS1. 1MXV-B 40-810/A 997
Dimensions not binding to be verified when ordering * Dimensions on request (1) Anti-vibration pads kit supplied loose as standard
h9v
h9f
h9I
I-MAT DN 2 h7
DN 1
h2
h3
n4 w4 lc m7
(1)
a1 a a1 m4 l7v-l7f-l7I
fg l6v-l6f-l6I
Connection
Collettori mm
TYPE TYPE
DN 1 DN 2 h9f h9v h7h9Ih3 h2 fg a a1 n4 w4 lc m4 m7 l6f l6v l6I l7f l7v l7I
BS.. 2MXV-B 25-204 (-ITT) BSM.. 2MXV-BM 25-204 671
BS.. 2MXV-B 25-205 (-ITT) BSM.. 2MXV-BM 25-205 695
BS.. 2MXV-B 25-206 (-ITT) BSM.. 2MXV-BM 25-206 719
BS.. 2MXV-B 25-207 (-ITT) BSM.. 2MXV-BM 25-207 G 1 1/2 G 1 1/2 965 1145 853 743 119 195 663 610 26,5 365 123 600 625 12,5 840 * * 215 * *
BS.. 2MXV-B 25-208 (-ITT) BSM.. 2MXV-BM 25-208 777
BS.. 2MXV-B 25-210 (-ITT) BSM.. 2MXV-BM 25-210 825
BS.. 2MXV-B 32-404 (-ITT) BSM.. 2MXV-BM 32-404 671
BS.. 2MXV-B 32-405 (-ITT) BSM.. 2MXV-BM 32-405 695
BS.. 2MXV-B 32-406 (-ITT) BSM.. 2MXV-BM 32-406 G2 G 2 965 1145 853 729 119 212 687 623 32 365 105 600 625 12,5 840 * * 215 * *
BS.. 2MXV-B 32-407 (-ITT) BSM.. 2MXV-BM 32-407 753
BS.. 2MXV-B 32-408/A (-ITT) 817
BS.. 2MXV-B 32-410/A (-ITT) 865
BS.. 2MXV-B 40-804 (-ITT) BSM.. 2MXV-BM 40-804 710
BS.. 2MXV-B 40-805/A (-ITT) 780
BS.. 2MXV-B 40-806/A (-ITT) G 2 1/2 G 2 1/2 965 1145 853 810 124 238 795 715 40 365 143 600 625 12,5 840 * * 215 * *
BS.. 2MXV-B 40-807/A (-ITT) 866
BS.. 2MXV-B 40-808/A (-ITT) 896
BS.. 2MXV-B 40-810/A (-ITT) 956
Dimensions not binding to be verified when ordering * Dimensions on request (1) Anti-vibration pads kit supplied loose as standard
571
BS. MXV-B Pressure boosting sets with 1 to 3 Vertical Multi-Stage Pumps
Fixed speed pump or Variable speed pump (frequency converter)
h9v
h9f
h9I
I-MAT DN 2 h7
DN 1
h2
h3
n4 w4 lc m7
(1)
a1 a a1 m4 l7v-l7f-l7i
fg l6v-l6f-l6i
Connection
Collettori mm
TYPE
DN 1 DN 2 h9f h9v h9i h7 h3 h2 fg a a1 n4 w4 lc m4 m7 l6f l6v l6I l7f l7v l7i
BS.. 3MXV-B 25-204 (-ITT) 686
BS.. 3MXV-B 25-205 (-ITT) 710
BS.. 3MXV-B 25-206 (-ITT) 734
BS.. 3MXV-B 25-207 (-ITT) G2 G2 965 1145 853 758 134 216 681 617 32 406 102 950 1000 25 840 * * 215 * *
BS.. 3MXV-B 25-208 (-ITT) 792
BS.. 3MXV-B 25-210 (-ITT) 840
BS.. 3MXV-B 32-404 (-ITT) 686
BS.. 3MXV-B 32-405 (-ITT) 710
BS.. 3MXV-B 32-406 (-ITT) G 2 1/2 G 2 1/2 965 1145 853 744 134 234 711 631 40 406 84 950 1000 25 840 * * 215 * *
BS.. 3MXV-B 32-407 (-ITT) 768
BS.. 3MXV-B 32-408/A (-ITT) 832
BS.. 3MXV-B 32-410/A (-ITT) 880
BS.. 3MXV-B 40-804 (-ITT) 725
BS.. 3MXV-B 40-805/A (-ITT) 795
BS.. 3MXV-B 40-806/A (-ITT) G3 G3 965 1145 853 825 139 259 817 720 48,5 406 121 950 1000 25 840 * * 215 * *
BS.. 3MXV-B 40-807/A (-ITT) 881
BS.. 3MXV-B 40-808/A (-ITT) 911
BS.. 3MXV-B 40-810/A (-ITT) 971
Dimensions not binding to be verified when ordering * Dimensions on request (1) Anti-vibration pads kit supplied loose as standard
572
BS. MXVB. EM Pressure boosting sets with 1 to 3 vertical multi-stage
pumps with EASYMAT frequency converter
DN2
h2
H
4.93.336.1
made in italy
DN1
B2 m1
h1
B L2
L1
Mains: 1~
Aliment.: 1 ~230V
230 V Mains: 1~ 1230V
Aliment.: ~ 230 V Connection mm
Motore: 230 V
3 ~230V mains ~ 230 V
Motore:1~ 1230V P2
Motor: 3~ aliment. motor
motore Motor:
A A A kW HP DN1 DN2 H h1 h2 L1 L2 m1 B B2
BSM1V 1MXV-B 25-204-EMT 5,4 3,3 BSM1V 1MXV-BM 25-204-EMM 5,8 0,75 1
BSM1V 1MXV-B 25-205-EMT 5,4 3,3 BSM1V 1MXV-BM 25-205-EMM 5,8 0,75 1
BSM1V 1MXV-B 25-206/A-EMT 7,1 4,7 BSM1V 1MXV-BM 25-206-EMM 7,4 1,1 1,5 G1 G1 577 75 437 588 262 150 218 210
BSM1V 1MXV-B 25-207/A-EMT 7,1 4,7 BSM1V 1MXV-BM 25-207-EMM 7,4 1,1 1,5
BSM1V 1MXV-B 25-208/A-EMT 10,8 7,5 1,5 2
BSM1V 1MXV-B 25-210/A-EMT 10,8 7,5 1,5 2
BSM1V 1MXV-B 32-404/A-EMT 7,1 4,7 BSM1V 1MXV-BM 32-404-EMM 7,4 1,1 1,5
BSM1V 1MXV-B 32-405/A-EMT 7,1 4,7 BSM1V 1MXV-BM 32-405-EMM 7,4 1,1 1,5
BSM1V 1MXV-B 32-406/A-EMT 10,8 7,5 1,5 2
G 1 1/4 G 1 1/4 600 75 458 633 288 150 218 210
BSM1V 1MXV-B 32-407/A-EMT 10,8 7,5 1,5 2
BSM1V 1MXV-B 32-408/B-EMT 13,2 9,15 2,2 3
BSM1V 1MXV-B 32-410/B-EMT 13,2 9,15 2,2 3
BSM1V 1MXV-B 40-804/A-EMT 10,8 7,5 1,5 2
BSM1V 1MXV-B 40-805/B-EMT 13,2 9,15 2,2 3 G 1 1/2 G 1 1/2 623 80 470 675 318 190 246 246
BSM1V 1MXV-B 40-806/B-EMT 13,2 9,15 2,2 3
Dimensions not binding to be verified when ordering
573
BS. MXVB. EM Pressure boosting sets with 1 to 3 vertical multi-stage
pumps with EASYMAT frequency converter
DN2
h5
h7
h2
made in italy made in italy
DN1
h1
4.93.336.2
m1
B (1)
L2
B2 L1
Mains: ~ 230 V
Aliment.:1~ 1230V Connection mm
~ 230 V
Motore: 3~ 3230V P2
Motor: mains motore
aliment. motor
A A kW HP DN1 DN2 h5 h7 h1 h2 L1 L2 m1 B B2
BSM2V 2MXV-B 25-204-EMT 2 x 5,4 2 x 3,3 2 x 0,75 2x1 609
BSM2V 2MXV-B 25-205-EMT 2 x 5,4 2 x 3,3 2 x 0,75 2x1 632
BSM2V 2MXV-B 25-206/A-EMT 2 x 7,1 2 x 4,7 2 x 1,1 2 x 1,5
G 1 1/2 G 1 1/2 690 656 119 419 759 305 365 600 625
BSM2V 2MXV-B 25-207/A-EMT 2 x 7,1 2 x 4,7 2 x 1,1 2 x 1,5 680
BSM2V 2MXV-B 25-208/A-EMT 2 x 10,8 2 x 7,5 2 x 1,5 2x2 704
BSM2V 2MXV-B 25-210/A-EMT 2 x 10,8 2 x 7,5 2 x 1,5 2x2 752
BSM2V 2MXV-B 32-404/A-EMT 2 x 7,1 2 x 4,7 2 x 1,1 2 x 1,5 609
BSM2V 2MXV-B 32-405/A-EMT 2 x 7,1 2 x 4,7 2 x 1,1 2 x 1,5 632
BSM2V 2MXV-B 32-406/A-EMT 2 x 10,8 2 x 7,5 2 x 1,5 2x2 656
G2 G2 713 119 443 810 336 365 600 625
BSM2V 2MXV-B 32-407/A-EMT 2 x 10,8 2 x 7,5 2 x 1,5 2x2 680
BSM2V 2MXV-B 32-408/B-EMT 2 x 13,2 2 x 9,15 2 x 2,2 2x3 744
BSM2V 2MXV-B 32-410/B-EMT 2 x 13,2 2 x 9,15 2 x 2,2 2x3 792
BSM2V 2MXV-B 40-804/A-EMT 2 x 10,8 2 x 7,5 2 x 1,5 2x2 637
BSM2V 2MXV-B 40-805/B-EMT 2 x 13,2 2 x 9,15 2 x 2,2 2x3 G 2 1/2 G 2 1/2 754 707 124 479 896 391 365 600 625
BSM2V 2MXV-B 40-806/B-EMT 2 x 13,2 2 x 9,15 2 x 2,2 2x3 737
(1) Anti-vibration pads kit supplied loose as standard
DN2
h7
h5
h2
DN1
h1
4.93.336.2
m1
B (1)
L2
B2 L1
Mains:
Aliment.:1~ 1230V
~ 230 V Connection mm
Motor:
Motore: 3~ 3230V
~ 230 V P2
mains motore
aliment. motor
A A kW HP DN1 DN2 h5 h7 h1 h2 L1 L2 m1 B B2
BSM3V 3MXV-B 25-204-EMT 3 x 5,4 3 x 3,3 3 x 0,75 3x1 624
BSM3V 3MXV-B 25-205-EMT 3 x 5,4 3 x 3,3 3 x 0,75 3x1 647
BSM3V 3MXV-B 25-206/A-EMT 3 x 7,1 3 x 4,7 3 x 1,1 3 x 1,5 671
G2 G2 711 134 425 766 311 406 950 1000
BSM3V 3MXV-B 25-207/A-EMT 3 x 7,1 3 x 4,7 3 x 1,1 3 x 1,5 695
BSM3V 3MXV-B 25-208/A-EMT 3 x 10,8 3 x 7,5 3 x 1,5 3x2 719
BSM3V 3MXV-B 25-210/A-EMT 3 x 10,8 3 x 7,5 3 x 1,5 3x2 767
BSM3V 3MXV-B 32-404/A-EMT 3 x 7,1 3 x 4,7 3 x 1,1 3 x 1,5 624
BSM3V 3MXV-B 32-405/A-EMT 3 x 7,1 3 x 4,7 3 x 1,1 3 x 1,5 647
BSM3V 3MXV-B 32-406/A-EMT 3 x 10,8 3 x 7,5 3 x 1,5 3x2 671
G 2 1/2 G 2 1/2 736 134 451 822 344 406 950 1000
BSM3V 3MXV-B 32-407/A-EMT 3 x 10,8 3 x 7,5 3 x 1,5 3x2 695
BSM3V 3MXV-B 32-408/B-EMT 3 x 13,2 3 x 9,15 3 x 2,2 3x3 759
BSM3V 3MXV-B 32-410/B-EMT 3 x 13,2 3 x 9,15 3 x 2,2 3x3 807
BSM3V 3MXV-B 40-804/A-EMT 3 x 10,8 3 x 7,5 3 x 1,5 3x2 652
BSM3V 3MXV-B 40-805/B-EMT 3 x 13,2 3 x 9,15 3 x 2,2 3x3 G3 G3 776 722 139 485 895 397 406 950 1000
BSM3V 3MXV-B 40-806/B-EMT 3 x 13,2 3 x 9,15 3 x 2,2 3x3 752
Dimensions not binding to be verified when ordering (1) Anti-vibration pads kit supplied loose as standard
574
BS. MXV Pressure boosting sets with 1 to 3 Vertical Multi-Stage Pumps
Fixed speed pump or Variable speed pump (frequency converter)
Coverage chart
120 400
H
ft
100
300
80
H 1-3MXV
m
60 200
40
100
20
0
2 m3 /h 5 10 20 30 40 50 100 150 200 300 400
Q l/min 100 150 200 300 400500 1000 2000 3000 5000
72.949.C
Operation Construction
BS 1-6F Pressure boosting sets with 1 to 6 fixed speed pump. - Automatic pressure boosting plant consisting of 1 to 6 vertical multi-
Sets with 4,5 and 6 pumps on request. stage pumps complete with ball, non return valve on the suction side
Depending on the reduction of the pressure in the system, and ball valves on the delivery side.
the pressure switches (pressure transducer for 3-pump sets)
determine the starting up of the pumps in sequence and the Suction and delivery manifolds for boosting sets with 2,3 pumps:
microprocessor alternates the starts. - stainless steel AISI 304.
Connections are located on the delivery manifold for the installation of
vessels G1 connection.
BS2-3V Pressure boosting sets with 2 to 3 variable speed pumps
(with I-MAT). Electrical control boards:
Depending on water consumption, one or more pumps are - with microprocessor for fixed speed pump units. Motor starting is D.O.L.
activated, all at variable speed, in order to guarantee the up to 5,5 kW and Y/Δ for power rating 7,5 up to 37 kW.
quantity of water required at the set pressure. - with frequency converter for variable speed pump units.
The unit includes one pressure gauge and three adjustable differential
pressure switches or pressure transducer.
BS1V2-5F Pressure boosting sets with 1 variable speed pump (with
frequency converter into the control panel) and from 1 to 5
Applications
fixed speed pumps To supply water in civil and industrial buildings.
Sets with 4,5 and 6 pumps on request. As pressure boosting pump to increase water pressure when needed
According to the water consumption, one or more pumps (follow local rules).
start, one at variable speed and the others at fixed speed,
to grant the water quantity required at the set pressure. Motors
2-pole induction motors, 50 Hz, n ≈ 2900 rpm, suitable for operation with
frequency converter.
BS1-6V Pressure boosting sets with 1 to 6 variable speed pumps - Three-phase 230/400V ± 10% up to 3 kW;
400/690V ± 10% for 4 kW to 37 kW;
(with frequency converter into the control panel).
- Single-phase 230 V ± 10%, (on request).
Sets with 4,5 and 6 pumps on request.
Insulation class F.
Depending on water consumption, one or more pumps are
Protection IP 55.
activated, all at variable speed, in order to guarantee the
Constructed in accordance with: IEC 60034.
quantity of water required at the set pressure.
Other voltages and frequencies on request.
Vessels on request
When installing the unit, connect in the delivery section to a diaphragm
or galvanised tank.
The recommended sized are shown in the following page.
575
BS. MXV Pressure boosting sets with 1 to 3 Vertical Multi-Stage Pumps
Fixed speed pump or Variable speed pump (frequency converter)
Coverage chart
1-3MXV 25 400
1-3MXV 32 400
120 120
100 100
12 12
300 300
80 10 H 80 10 H
ft ft
H H
m m
8 8
60 200 60 200
7 7
6 6
40 5 40 5
4 100 4 100
20 20
0 0 0 0
0 m 3/h 3 6 9 12 15 0 m3/h 6 12 18 24 27
0 Q l/min 50 100 150 200 250 0 Q l/min 100 200 300 400
72.951.1C 72.951.2C
0 U.S. g.p.m. 40 60 80 100 120 140 160 180 0 U.S. g.p.m. 100 200 300
0 Imp. g.p.m. 40 60 80 100 120 140 0 Imp. g.p.m. 100 150 200 250
140 140
1-3MXV 40 400
1-3MXV 50-16 400
120 120
ft
8
11
100 100
10 7
300 300
80 H 6
80
8 ft
H
m 5
7 H
60 200 m 200
6 4
5
3
40 40
4
100 100
20 20
0 0 0 0
0 6 12 18 24 30 36 42 0 15 30 45 60 75
Qm /h
3
Q m /h 300
3
0 l/min 200 300 400 500 600 700 0 l/min 600 900 1200
72.951.3C
72.953.1C
576
BS. MXV Pressure boosting sets with 1 to 3 Vertical Multi-Stage Pumps
Fixed speed pump or Variable speed pump (frequency converter)
Coverage chart
0 U.S. g.p.m. 100 150 200 250 300 0 U.S. g.p.m. 100 150 200 250 300 350
0 Imp. g.p.m. 100 150 200 250 0 Imp. g.p.m. 100 150 200 250 300
140 140
100 100
10
300 8 300
9
80 ft 80 7 ft
8
H H 6
m 7 m
200 200
60 6 60 5
5
4
4
40 40
3
3 100 100
20 20
00 0
0
0 m 3/h 12 24 36 48 60 72 0 m 3/h 12 24 36 48 60 72 84
0 Q l/min 300 450 600 750 900 1050 1200 0
Q l/min
300 450 600 750 900 1050 1200 1350
0 U.S. g.p.m. 200 300 400 500 600 0 U.S. g.p.m. 200 300 400 500 600 700 800
0 Imp. g.p.m. 200 300 400 500 0 Imp. g.p.m. 200 300 400 500 600
140 140
ft
100 100
7 7
300 300
6 6
80 80 H
ft
H
5 m 5
H
200 200
4 60
m
4
3
40 3
40
2 100 100
2
20 20
0 0 0
0 m 3/h 50 100 150 0 m3/h 40 60 80 100 120 140 160 180 0
0
Q l/min 500 1000 1500 2000 2500 Q
0 l/min 500 1000 1500 2000 2500 3000
72.953.2C
72.953.3C
577
BS. MXV Pressure boosting sets with 1 to 3 Vertical Multi-Stage Pumps
Fixed speed pump or Variable speed pump (frequency converter)
Coverage chart
0 U.S. g.p.m. 500 1000 0 U.S. g.p.m. 400 600 800 1000 1200 1400 1600
0 Imp. g.p.m. 500 1000 0 Imp. g.p.m. 400 600 800 1000 1200
140 140
5-2R 5-2R
100 100
4 300 4 300
80 H 80 4-2R H
4-2R
ft ft
H H
3 3
m m
60 200 60 200
3-2R 3-2R
2 2
40 40
2-2R 2-2R
100 100
20 20
0 0 0 0
0 m /h
3 60 120 180 240 280 0 m3/h 80 120 160 200 240 280 320 360
0 Q l/min 1000 2000 3000 4000 Q
0 l/min 1000 2000 3000 4000 5000 6000
72.951.2C
72.953.3C
578
BS. MXV Pressure boosting sets with 1 to 3 Vertical Multi-Stage Pumps
Fixed speed pump or Variable speed pump (frequency converter)
Performance
BS1F BSM1F
Mains: 400V 3~ Mains: 230V 1~ Motor Pres. switch 1 Vessel Vessel
Motor: 400V 3~ Motor: 230V 1~ bar Membrane
kW HP min max litre litre
BS1F 1MXV 25-304 O BSM1F 1MXV 25-304 O 0,75 1 2,5 4 40 100
BS1F 1MXV 25-305 O BSM1F 1MXV 25-305 O 0,75 1 3,5 5 50 100
BS1F 1MXV 25-306 O BSM1F 1MXV 25-306 O 1,1 1,5 4 6 50 100
BS1F 1MXV 25-307 O BSM1F 1MXV 25-307 O 1,1 1,5 5 7 60 100
BS1F 1MXV 25-308 O BSM1F 1MXV 25-308 O 1,5 2 6 8 100 100
BS1F 1MXV 25-310 O 1,5 2 6,5 8,5 100 200
BS1F 1MXV 25-312 O 2,2 3 8 10 200 200
BS1F 1MXV 32-504 O BSM1F 1MXV 32-504 O 1,1 1,5 2,3 3,8 100 100
BS1F 1MXV 32-505 O BSM1F 1MXV 32-505 O 1,1 1,5 3,4 4,9 100 200
BS1F 1MXV 32-506 O BSM1F 1MXV 32-506 O 1,5 2 4 6 100 200
BS1F 1MXV 32-507 O BSM1F 1MXV 32-507 O 1,5 2 5 7 100 200
BS1F 1MXV 32-508 O 2,2 3 6 8 200 300
BS1F 1MXV 32-510 O 2,2 3 7 9 300 500
BS1F 1MXV 32-512 O 3 4 8,5 10,5 300 500
BS1F 1MXV 40-904 O BSM1F 1MXV 40-904 O 1,5 2 2,5 4 200 300
BS1F 1MXV 40-905 O 2,2 3 3,5 5 300 500
BS1F 1MXV 40-906 O 2,2 3 4 6 300 500
BS1F 1MXV 40-907 O 3 4 5 7 500 800
BS1F 1MXV 40-908 O 3 4 6 8 500 800
BS1F 1MXV 40-910 O 4 5,5 8 10 1000 1000
BS1F 1MXV 40-911 O 4 5,5 9 11 1000 1000
BS1F 1MXV 50-1503/A 2,2 3 2,7 3,5 500 1000
BS1F 1MXV 50-1504 3 4 3,2 4,7 500 1000
BS1F 1MXV 50-1505 4 5,5 4,3 5,9 500 1000
BS1F 1MXV 50-1506 5,5 7,5 5,3 7,1 500 1000
BS1F 1MXV 50-1507 5,5 7,5 6,4 8,3 750 1000
BS1F 1MXV 50-1508/A 5,5 7,5 7,5 9,6 750 1000
BS1F 1MXV 50-1509 7,5 10 9,3 10,8 1000 1500
BS1F 1MXV 50-1510 7,5 10 10,4 11,9 1000 1500
BS1F 1MXV 50-2003 3 4 3,0 3,8 750 1000
BS1F 1MXV 50-2004 4 5,5 3,5 5,1 750 1000
BS1F 1MXV 50-2005 5,5 7,5 4,7 6,4 750 1000
BS1F 1MXV 50-2006 7,5 10 5,8 7,7 750 1000
BS1F 1MXV 50-2007 7,5 10 6,9 8,9 1000 1500
BS1F 1MXV 50-2008 9,2 12,5 8,7 10,2 1000 2000
BS1F 1MXV 50-2009 9,2 12,5 10,4 11,9 1500 2000
BS1F 1MXV 65-3202/D 4 5,5 2 3 1000 2000
BS1F 1MXV 65-3203/C 5,5 7,5 3,3 4,8 1500 3000
BS1F 1MXV 65-3204/C 7,5 10 4,5 6,5 1500 3000
BS1F 1MXV 65-3205/D 11 15 6 8 2000 4000
BS1F 1MXV 65-3206/D 11 15 6,5 9,5 3000 4000
BS1F 1MXV 65-3207/D 15 20 7,5 10,5 4000 5000
BS1F 1MXV 80-4802/C 5,5 7,5 2 3,2 1500 3000
BS1F 1MXV 80-4803/C 7,5 10 3,5 5 2000 3000
BS1F 1MXV 80-4804/D 11 15 4,5 6,5 3000 4000
BS1F 1MXV 80-4805/D 15 20 6 8 4000 5000
BS1F 1MXV 80-4806/D 15 20 6,5 9,5 5000 -
BS1F 1MXV 80-4807/E 18,5 25 8 11 5000 -
579
BS. MXV Pressure boosting sets with 1 to 3 Vertical Multi-Stage Pumps
Fixed speed pump or Variable speed pump (frequency converter)
Performance
BS2F BSM2F
Mains: 400V 3~ Mains: 230V 1~ Motor Pres. switch 1 Pres. switch 2 Vessel Vessel
Motor: 400V 3~ Motor: 230V 1~ bar bar Membrane
kW HP min max min max litre litre
BS2F 2MXV 25-304 O BSM2F 2MXV 25-304 O 0,75 x2 1 x2 2,5 4 2,2 3,7 40 100
BS2F 2MXV 25-305 O BSM2F 2MXV 25-305 O 0,75 x2 1 x2 3,5 5 3 4,5 50 100
BS2F 2MXV 25-306 O BSM2F 2MXV 25-306 O 1,1 x2 1,5 x2 4 6 3,5 5,5 50 100
BS2F 2MXV 25-307 O BSM2F 2MXV 25-307 O 1,1 x2 1,5 x2 5 7 4,5 6,5 60 100
BS2F 2MXV 25-308 O BSM2F 2MXV 25-308 O 1,5 x2 2 x2 6 8 5,5 7,5 100 100
BS2F 2MXV 25-310 O 1,5 x2 2 x2 6,5 8,5 6 8 100 200
BS2F 2MXV 25-312 O 2,2 x2 3 x2 8 10 7,5 9,5 200 200
BS2F 2MXV 32-504 O BSM2F 2MXV 32-504 O 1,1 x2 1,5 x2 2,3 3,8 1,8 3,3 100 100
BS2F 2MXV 32-505 O BSM2F 2MXV 32-505 O 1,1 x2 1,5 x2 3,4 4,9 3 4,5 100 200
BS2F 2MXV 32-506 O BSM2F 2MXV 32-506 O 1,5 x2 2 x2 4 6 3,5 5,5 100 200
BS2F 2MXV 32-507 O BSM2F 2MXV 32-507 O 1,5 x2 2 x2 5 7 4,5 6,5 100 200
BS2F 2MXV 32-508 O 2,2 x2 3 x2 6 8 5,5 7,5 200 300
BS2F 2MXV 32-510 O 2,2 x2 3 x2 7 9 6,5 8,5 300 500
BS2F 2MXV 32-512 O 3 x2 4 x2 8,5 10,5 8 10 300 500
BS2F 2MXV 40-904 O BSM2F 2MXV 40-904 O 1,5 x2 2 x2 2,5 4 2,2 3,7 200 300
BS2F 2MXV 40-905 O 2,2 x2 3 x2 3,5 5 3 4,5 300 500
BS2F 2MXV 40-906 O 2,2 x2 3 x2 4 6 3,5 5,5 300 500
BS2F 2MXV 40-907 O 3 x2 4 x2 5 7 4,5 6,5 500 800
BS2F 2MXV 40-908 O 3 x2 4 x2 6 8 5,5 7,5 500 800
BS2F 2MXV 40-910 O 4 x2 5,5 x2 8 10 7,5 9,5 1000 1000
BS2F 2MXV 40-911 O 4 x2 5,5 x2 9 11 8,5 10,5 1000 1000
BS2F 2MXV 50-1503/A 2,2 x2 3 x2 2,7 3,5 2,4 3,2 500 1000
BS2F 2MXV 50-1504 3 x2 4 x2 3,2 4,7 2,9 4,4 500 1000
BS2F 2MXV 50-1505 4 x2 5,5 x2 4,3 5,9 4,0 5,6 500 1000
BS2F 2MXV 50-1506 5,5 x2 7,5 x2 5,3 7,1 5,0 6,8 500 1000
BS2F 2MXV 50-1507 5,5 x2 7,5 x2 6,4 8,3 6,1 8,0 750 1000
BS2F 2MXV 50-1508/A 5,5 x2 7,5 x2 7,5 9,6 7,2 9,3 750 1000
BS2F 2MXV 50-1509 7,5 x2 10 x2 9,3 10,8 9,0 10,5 1000 1500
BS2F 2MXV 50-1510 7,5 x2 10 x2 10,4 11,9 10,1 11,6 1000 1500
BS2F 2MXV 50-2003 3 x2 4 x2 3,0 3,8 2,7 3,5 750 1000
BS2F 2MXV 50-2004 4 x2 5,5 x2 3,5 5,1 3,3 4,8 750 1000
BS2F 2MXV 50-2005 5,5 x2 7,5 x2 4,7 6,4 4,4 6,1 750 1000
BS2F 2MXV 50-2006 7,5 x2 10 x2 5,8 7,7 5,5 7,4 750 1000
BS2F 2MXV 50-2007 7,5 x2 10 x2 6,9 8,9 6,6 8,6 100 1500
BS2F 2MXV 50-2008 9,2 x2 12,5 x2 8,7 10,2 8,4 9,9 1000 2000
BS2F 2MXV 50-2009 9,2 x2 12,5 x2 10,4 11,9 10,1 11,6 1500 2000
BS2F 2MXV 65-3202/D 4 x2 5,5 x2 2 3 1,7 2,7 1000 2000
BS2F 2MXV 65-3203/C 5,5 x2 7,5 x2 3,3 4,8 2,8 4,3 1500 3000
BS2F 2MXV 65-3204/C 7,5 x2 10 x2 4,5 6,5 4 6 1500 3000
BS2F 2MXV 65-3205/D 11 x2 15 x2 6 8 5,5 7,5 2000 4000
BS2F 2MXV 65-3206/D 11 x2 15 x2 6,5 9,5 6 9 3000 4000
BS2F 2MXV 65-3207/D 15 x2 20 x2 7,5 10,5 7 10 4000 5000
BS2F 2MXV 80-4802/C 5,5 x2 7,5 x2 2 3,2 1,6 2,8 1500 3000
BS2F 2MXV 80-4803/C 7,5 x2 10 x2 3,5 5 3 4,5 2000 3000
BS2F 2MXV 80-4804/D 11 x2 15 x2 4,5 6,5 4 6 3000 4000
BS2F 2MXV 80-4805/D 15 x2 20 x2 6 8 5,5 7,5 4000 5000
BS2F 2MXV 80-4806/D 15 x2 20 x2 6,5 9,5 6 9 5000 -
BS2F 2MXV 80-4807/E 18,5 x2 25 x2 8 11 7,5 10,5 5000 -
BS2F 2MXV 100-6502-2R 7,5 x2 10 x2 2,2 2,8 1,9 2,5 3000 -
BS2F 2MXV 100-6502 11 x2 15 x2 3,8 4,4 3,5 4,1 - -
BS2F 2MXV 100-6503-2R 15 x2 20 x2 4,3 4,9 4 4,6 - -
BS2F 2MXV 100-6503/A 18,5 x2 25 x2 5,8 6,7 5,3 6,2 - -
BS2F 2MXV 100-6504-2R/A 18,5 x2 25 x2 7,2 8,4 6,6 7,8 - -
BS2F 2MXV 100-6504 22 x2 30 x2 7,7 8,9 7,1 8,3 - -
BS2F 2MXV 100-6505-2R 30 x2 40 x2 8,3 9,8 7,5 9 - -
BS2F 2MXV 100-6505 30 x2 40 x2 9,8 11,3 9 10,5 - -
BS2F 2MXV 100-9002-2R 11 x2 15 x2 2,9 3,9 2,4 3,4 - -
BS2F 2MXV 100-9002 15 x2 20 x2 3,7 5,2 3 4,5 - -
BS2F 2MXV 100-9003-2R/A 18,5 x2 25 x2 4,6 6,1 4,1 5,6 - -
BS2F 2MXV 100-9003 22 x2 30 x2 6,2 7,7 5,4 6,9 - -
BS2F 2MXV 100-9004-2R 30 x2 40 x2 7,4 8,9 6,6 8,1 - -
BS2F 2MXV 100-9004 30 x2 40 x2 8,5 10 7,8 9,3 - -
BS2F 2MXV 100-9005-2R 37 x2 50 x2 9,5 11 8,8 10,3 - -
580
BS. MXV Pressure boosting sets with 1 to 3 Vertical Multi-Stage Pumps
Fixed speed pump or Variable speed pump (frequency converter)
Performance
BS3F
Mains: 400V 3~ Motor Pressure transducer Vessel Vessel
Motor: 400V 3~ bar Membrane
kW HP min max litre litre
BS3F 3MXV 25-304 O 0,75 x3 1 x3 3 3,9 60 100
BS3F 3MXV 25-305 O 0,75 x3 1 x3 3,3 4,8 80 100
BS3F 3MXV 25-306 O 1,1 x3 1,5 x3 4,1 5,8 80 100
BS3F 3MXV 25-307 O 1,1 x3 1,5 x3 5 6,7 100 100
BS3F 3MXV 25-308 O 1,5 x3 2 x3 5,9 7,8 100 100
BS3F 3MXV 25-310 O 1,5 x3 2 x3 7,5 9,7 150 200
BS3F 3MXV 25-312 O 2,2 x3 3 x3 10,1 11,6 200 300
BS3F 3MXV 32-504 O 1,1 x3 1,5 x3 3 3,8 300 500
BS3F 3MXV 32-505 O 1,1 x3 1,5 x3 3,2 4,7 200 300
BS3F 3MXV 32-506 O 1,5 x3 2 x3 4 5,7 200 300
BS3F 3MXV 32-507 O 1,5 x3 2 x3 4,9 6,6 300 500
BS3F 3MXV 32-508 O 2,2 x3 3 x3 5,7 7,6 300 500
BS3F 3MXV 32-510 O 2,2 x3 3 x3 7,4 9,5 200 300
BS3F 3MXV 32-512 O 3 x3 4 x3 9,8 11,3 300 500
BS3F 3MXV 40-904 O 1,5 x3 2 x3 3 3,9 500 800
BS3F 3MXV 40-905 O 2,2 x3 3 x3 3,4 4,9 500 800
BS3F 3MXV 40-906 O 2,2 x3 3 x3 4,3 5,9 500 800
BS3F 3MXV 40-907 O 3 x3 4 x3 5,1 6,9 750 1000
BS3F 3MXV 40-908 O 3 x3 4 x3 6 7,9 500 800
BS3F 3MXV 40-910 O 4 x3 5,5 x3 7,8 9,9 500 1000
BS3F 3MXV 40-911 O 4 x3 5,5 x3 9,4 10,9 1000 1500
BS3F 3MXV 50-1503/A 2,2 x3 3 x3 2,7 3,5 750 1500
BS3F 3MXV 50-1504 3 x3 4 x3 3,2 4,7 750 1500
BS3F 3MXV 50-1505 4 x3 5,5 x3 4,3 5,9 750 1500
BS3F 3MXV 50-1506 5,5 x3 7,5 x3 5,3 7,1 750 1500
BS3F 3MXV 50-1507 5,5 x3 7,5 x3 6,4 8,3 750 1500
BS3F 3MXV 50-1508/A 5,5 x3 7,5 x3 7,5 9,6 750 1500
BS3F 3MXV 50-1509 7,5 x3 10 x3 9,3 10,8 750 1500
BS3F 3MXV 50-1510 7,5 x3 10 x3 10,4 11,9 750 1500
BS3F 3MXV 50-2003 3 x3 4 x3 3 3,8 750 1500
BS3F 3MXV 50-2004 4 x3 5,5 x3 3,5 5,1 750 1500
BS3F 3MXV 50-2005 5,5 x3 7,5 x3 4,7 6,4 750 1500
BS3F 3MXV 50-2006 7,5 x3 10 x3 5,8 7,7 750 1500
BS3F 3MXV 50-2007 7,5 x3 10 x3 6,9 8,9 750 1500
BS3F 3MXV 50-2008 9,2 x3 12,5 x3 8,7 10,2 750 1500
BS3F 3MXV 50-2009 9,2 x3 12,5 x3 10,4 11,9 750 1500
BS3F 3MXV 65-3202/D 4 x3 5,5 x3 2,3 3,1 2000 4000
BS3F 3MXV 65-3203/C 5,5 x3 7,5 x3 3,2 4,7 2000 3000
BS3F 3MXV 65-3204/C 7,5 x3 10 x3 4,6 6,3 2000 4000
BS3F 3MXV 65-3205/D 11 x3 15 x3 5,9 7,8 3000 4000
BS3F 3MXV 65-3206/D 11 x3 15 x3 7,3 9,4 3000 5000
BS3F 3MXV 65-3207/D 15 x3 20 x3 9,5 11 - 6000
BS3F 3MXV 80-4802/C 5,5 x3 7,5 x3 2,5 3,3 3000 6000
BS3F 3MXV 80-4803/C 7,5 x3 10 x3 3,4 4,9 2000 4000
BS3F 3MXV 80-4804/D 11 x3 15 x3 4,8 6,6 3000 5000
BS3F 3MXV 80-4805/D 15 x3 20 x3 6,3 8,2 - 6000
BS3F 3MXV 80-4806/D 15 x3 20 x3 7,7 9,8 - 6000
BS3F 3MXV 80-4807/E 18,5 x3 25 x3 10 11,5 - 9000
BS3F 3MXV 100-6502-2R 7,5 x3 10 x3 2,6 3,4 - -
BS3F 3MXV 100-6502 11 x3 15 x3 3,2 4,7 - -
BS3F 3MXV 100-6503-2R 15 x3 20 x3 4,1 5,8 - -
BS3F 3MXV 100-6503/A 18,5 x3 25 x3 5,1 6,9 - -
BS3F 3MXV 100-6504-2R/A 18,5 x3 25 x3 6,1 8,1 - -
BS3F 3MXV 100-6504 22 x3 30 x3 7,2 9,3 - -
BS3F 3MXV 100-6505-2R 30 x3 40 x3 9,1 10,6 - -
BS3F 3MXV 100-6505 30 x3 40 x3 10,3 11,8 - -
BS3F 3MXV 100-9002-2R 11 x3 15 x3 3 3,9 - -
BS3F 3MXV 100-9002 15 x3 20 x3 3,6 5,1 - -
BS3F 3MXV 100-9003-2R/A 18,5 x3 25 x3 4,7 6,4 - -
BS3F 3MXV 100-9003 22 x3 30 x3 5,8 7,7 - -
BS3F 3MXV 100-9004-2R 30 x3 40 x3 7,1 9,1 - -
BS3F 3MXV 100-9004 30 x3 40 x3 8,7 10,2 - -
BS3F 3MXV 100-9005-2R 37 x3 50 x3 10,1 11,6 - -
581
BS. MXV Pressure boosting sets with 1 to 3 Vertical Multi-Stage Pumps
Fixed speed pump or Variable speed pump (frequency converter)
Performance
BS.. BS.. ..-ITT
PUMPS Nos P
P22 PUMPS Nos P
P22
N. POMPE PUMPPOMPE
TYPE Per pompa N. POMPE PUMP TYPE Per pompa
TIPO For each pump TIPO POMPE For each pump
1 2 3 4 5 6 kW HP 2 3 kW HP
MXV 25-304 O 0,75 1 MXV 25-304 O-ITT 0,75 1
MXV 25-305 O 0,75 1 MXV 25-305 O-ITT 0,75 1
MXV 25-306 O 1,1 1,5 MXV 25-306 O-ITT 1,1 1,5
MXV 25-307 O 1,1 1,5 MXV 25-307 O-ITT 1,1 1,5
MXV 25-308 O 1,5 2 MXV 25-308 O-ITT 1,5 2
MXV 25-310 O 1,5 2 MXV 25-310 O-ITT 1,5 2
MXV 25-312 O 2,2 3 MXV 25-312 O-ITT 2,2 3
MXV 32-504 O 1,1 1,5 MXV 32-504 O-ITT 1,1 1,5
MXV 32-505 O 1,1 1,5 MXV 32-505 O-ITT 1,1 1,5
MXV 32-506 O 1,5 2 MXV 32-506 O-ITT 1,5 2
MXV 32-507 O 1,5 2 MXV 32-507 O-ITT 1,5 2
MXV 32-508 O 2,2 3 MXV 32-508 O-ITT 2,2 3
MXV 32-510 O 2,2 3 MXV 32-510 O-ITT 2,2 3
MXV 32-512 O 3 4 MXV 32-512 O-ITT 3 4
MXV 40-904 O 1,5 2 MXV 40-904 O-ITT 1,5 2
MXV 40-905 O 2,2 3 MXV 40-905 O-ITT 2,2 3
MXV 40-906 O 2,2 3 MXV 40-906 O-ITT 2,2 3
MXV 40-907 O 3 4 MXV 40-907 O-ITT 3 4
MXV 40-908 O 3 4 MXV 40-908 O-ITT 3 4
MXV 40-910 O 4 5,5 MXV 40-910 O-ITT 4 5,5
MXV 40-911 O 4 5,5 MXV 40-911 O-ITT 4 5,5
MXV 50-1503/A 2,2 3 MXV 50-1503/A-ITT 2,2 3
MXV 50-1504 3 4 MXV 50-1504-ITT 3 4
MXV 50-1505 4 5,5 MXV 50-1505-ITT 4 5,5
MXV 50-1506 5,5 7,5 MXV 50-1506-ITT 5,5 7,5
MXV 50-1507 5,5 7,5 MXV 50-1507-ITT 5,5 7,5
MXV 50-1508/A 5,5 7,5 MXV 50-1508/A-ITT 5,5 7,5
MXV 50-1509 7,5 10 MXV 50-1509-ITT 7,5 10
BS1V BS2V BS3V BS4V BS5V BS6V MXV 50-1510 7,5 10 BS2V BS3V MXV 50-1510-ITT 7,5 10
BSM1V BS1V1F BS1V2F BS1V3F BS1V4F BS1V5F MXV 50-2003 3 4 -ITT -ITT MXV 50-2003-ITT 3 4
BSM1V1F* MXV 50-2004 4 5,5 MXV 50-2004-ITT 4 5,5
BSM2V** MXV 50-2005 5,5 7,5 MXV 50-2005-ITT 5,5 7,5
MXV 50-2006 7,5 10 MXV 50-2006-ITT 7,5 10
MXV 50-2007 7,5 10 MXV 50-2007-ITT 7,5 10
MXV 50-2008 9,2 12,5 MXV 50-2008-ITT 9,2 12,5
MXV 50-2009 9,2 12,5 MXV 50-2009-ITT 9,2 12,5
MXV 65-3202/D 4 5,5 MXV 65-3202/D-ITT 4 5,5
MXV 65-3203/C 5,5 7,5 MXV 65-3203/C-ITT 5,5 7,5
MXV 65-3204/C 7,5 10 MXV 65-3204/C-ITT 7,5 10
MXV 65-3205/D 11 15 MXV 65-3205/D-ITT 11 15
MXV 65-3206/D 11 15 MXV 65-3206/D-ITT 11 15
MXV 65-3207/D 15 20 MXV 65-3207/D-ITT 15 20
MXV 80-4802/C 5,5 7,5 MXV 80-4801/D-ITT 4 5,5
MXV 80-4803/C 7,5 10 MXV 80-4802/C-ITT 5,5 7,5
MXV 80-4804/D 11 15 MXV 80-4803/C-ITT 7,5 10
MXV 80-4805/D 15 20 MXV 80-4804/D-ITT 11 15
MXV 80-4806/D 15 20 MXV 80-4805/D-ITT 15 20
MXV 80-4807/E 18,5 25 MXV 80-4806/D-ITT 15 20
MXV 100-6502-2R 7,5 10 MXV 80-4807/E-ITT 18,5 25
MXV 100-6502 11 15 MXV 100-6501-ITT 5,5 7,5
MXV 100-6503-2R 15 20 MXV 100-6502-2R-ITT 7,5 10
MXV 100-6503/A 18,5 25 MXV 100-6502-ITT 11 15
MXV 100-6504-2R/A 18,5 25 MXV 100-6503-2R-ITT 15 20
MXV 100-6504 22 30 MXV 100-6503/A-ITT 18,5 25
MXV 100-6505-2R 30 40 MXV 100-6504-2R/A-ITT 18,5 25
MXV 100-6505 30 40 MXV 100-6504-ITT 22 30
MXV 100-9002-2R 11 15 MXV 100-9001-1R-ITT 5,5 7,5
MXV 100-9002 15 20 MXV 100-9001-ITT 7,5 10
MXV 100-9003-2R/A 18,5 25 MXV 100-9002-2R-ITT 11 15
MXV 100-9003 22 30 MXV 100-9002-ITT 15 20
MXV 100-9004-2R 30 40 MXV 100-9003-2R/A-ITT 18,5 25
MXV 100-9004 30 40 MXV 100-9003-ITT 22 30
MXV 100-9005-2R 37 50
582
BS. MXV Pressure boosting sets with 1 to 3 Vertical Multi-Stage Pumps
Fixed speed pump or Variable speed pump (frequency converter)
Dimensions and
weights
h9v
h9f
h7
DN1 DN2
h3
l7v
l7f w4 m7 m4 m8
(1)
n4 l6
fgv-fgf
Connection
Collettori
TYPE TYPE mm
DN 1 DN 2 h9f h9v h7 h3 m4 m7 m8 l6 n4 w4 fgf fgv l7f l7v
BS1. 1 MXV 25-304 O BSM1. 1 MXV 25-304 O 666
BS1. 1 MXV 25-305 O BSM1. 1 MXV 25-305 O 690
BS1. 1 MXV 25-306 O BSM1. 1 MXV 25-306 O 714
BS1. 1 MXV 25-307 O BSM1. 1 MXV 25-307 O G1 G1 862 1144 738 94 625 15 11 651 365 158 470 574 105 209
BS1. 1 MXV 25-308 O BSM1. 1 MXV 25-308 O 762
BS1. 1 MXV 25-310 O 811
BS1. 1 MXV 25-312 O 899
BS1. 1 MXV 32-504 O BSM1. 1 MXV 32-504 O 666
BS1. 1 MXV 32-505 O BSM1. 1 MXV 32-505 O 690
BS1. 1 MXV 32-506 O BSM1. 1 MXV 32-506 O 714
BS1. 1 MXV 32-507 O BSM1. 1 MXV 32-507 O G 1 1/4 G 1 1/4 862 1144 738 94 625 37 44 706 365 158 470 574 105 209
BS1. 1 MXV 32-508 O 802
BS1. 1 MXV 32-510 O 851
BS1. 1 MXV 32-512 O 915
BS1. 1 MXV 40-904 O BSM1. 1 MXV 40-904 O 711 574 209
BS1. 1 MXV 40-905 O 781 574 209
BS1. 1 MXV 40-906 O 811 574 209
BS1. 1 MXV 40-907 O G 1 1/2 G 1 1/2 862 1144 857 124 625 87 79 790 365 160 470 574 105 209
BS1. 1 MXV 40-908 O 887 574 209
BS1. 1 MXV 40-910 O 947 638 273
BS1. 1 MXV 40-911 O 977 638 273
Dimensions not binding to be verified when ordering (1) Anti-vibration pads kit supplied loose as standard
h9f-l7f= Fixed speed boosting sets
h9v-l7v= Variable speed boosting sets
583
BS. MXV Pressure boosting sets with 1 to 3 Vertical Multi-Stage Pumps
Fixed speed pump or Variable speed pump (frequency converter)
Dimensions and
weights
Fig. 1 Fig. 2
h9v
h7 h9f
DN 1 DN 2
DN 1 DN 2
h3 h3
m7 m8 w4
m4 m7 m4 m8 n4 l7v-l7f
l6 l6 fgv-fgf
TYPE Connection
Collettori mm
Fig. DN 1 DN 2 h9v h9f h7 h3 m4 m7 m8 I6 n4 w4 fgv fgf I7v I7f
BS1. 1MXV 50-1503/A 1335 1155 934 681 550 131 0
BS1. 1MXV 50-1504 1335 1155 980 681 550 131 0
BS1. 1MXV 50-1505 1344 1155 1028 745 550 195 0
1 BS1. 1MXV 50-1506 1344 1155 1167 745 550 195 0
G2 G2
BS1. 1MXV 50-1507 1344 1155 1215 225 950 27 4 919 550 205 745 550 195 0
BS1. 1MXV 50-1508/A 1344 1420 1263 745 695 195 145
BS1. 1MXV 50-1509 1344 1420 1311 745 695 195 145
BS1. 1MXV 50-1510 1344 1420 1359 745 695 195 145
BS1. 1MXV 50-2003 1335 1155 932 681 550 131 0
BS1. 1MXV 50-2004 1344 1155 967 745 550 195 0
BS1. 1MXV 50-2005 1344 1155 1119 745 550 195 0
1 G2 G2
BS1. 1MXV 50-2006 1344 1420 1167 225 950 27 4 919 550 205 745 695 195 145
BS1. 1MXV 50-2007 1344 1420 1215 745 695 195 145
BS1. 1MXV 50-2008 1344 1420 1367 745 695 195 145
BS1. 1MXV 50-2009 1344 1420 1415 745 695 195 145
BS1. 1MXV 65-3202/D 1344 1155 853 745 550 195 0
BS1. 1MXV 65-3203/C 1344 1155 947 745 550 195 0
BS1. 1MXV 65-3204/C 1344 1420 993 240 950 68 27 1042 550 205 745 695 195 145
2 G 2 1/2 G 2 1/2
BS1. 1MXV 65-3205/D 1344 1420 1189 745 695 195 145
BS1. 1MXV 65-3206/D 1344 1420 1235 745 695 195 145
BS1. 1MXV 65-3207/D 1344 1420 1306 745 695 195 145
BS1. 1MXV 80-4802/C 1344 1155 940 745 550 195 0
BS1. 1MXV 80-4803/C 1344 1420 1001 745 695 195 145
BS1. 1MXV 80-4804/D 1344 1420 1212 240 950 112 38 1100 550 205 745 695 195 145
2 G3 G3
BS1. 1MXV 80-4805/D 1344 1420 1299 745 695 195 145
BS1. 1MXV 80-4806/D 1344 1420 1360 745 695 195 145
BS1. 1MXV 80-4807/E 1548 1420 1498 685 695 135 145
Dimensions not binding to be verified when ordering h9f-fgf-l7f= Fixed speed boosting sets
h9v-fgv-l7v= Variable speed boosting sets
584
BS. MXV Pressure boosting sets with 1 to 3 Vertical Multi-Stage Pumps
Fixed speed pump or Variable speed pump (frequency converter)
h9v
h9f
h9i
I-MAT h7
DN 2
DN 1
h2
h3
n4 w4 lc m7
a1 a a1 (1) m4 l7v-l7f-l7I
fg l6v-l6f-l6I
Connection
Collettori mm
TYPE TYPE
DN 1 DN 2 h9f h9v h9i h7 h3 h2 fg a a1 n4 w4 lc m4 m7 l6f l6v l6i l7f l7v l7i
BS.. 2MXV 25-304 O (-ITT) BS.. 2MXV 25-304 O 666
BS.. 2MXV 25-305 O (-ITT) BS.. 2MXV 25-305 O 690
BS.. 2MXV 25-306 O (-ITT) BS.. 2MXV 25-306 O 714
BS.. 2MXV 25-307 O (-ITT) BS.. 2MXV 25-307 O G 1 1/2 G 1 1/2 864 1252 884 738 94 170 642 589 27 365 140 600 625 13 810 959 825 185 334 200
BS.. 2MXV 25-308 O (-ITT) BS.. 2MXV 25-308 O 762
BS.. 2MXV 25-310 O (-ITT) BS.. 2MXV 25-310 O 811
BS.. 2MXV 25-312 O (-ITT) BS.. 2MXV 25-312 O 899
BS.. 2MXV 32-504 O (-ITT) BS.. 2MXV 32-504 O 666
BS.. 2MXV 32-505 O (-ITT) BS.. 2MXV 32-505 O 690
BS.. 2MXV 32-506 O (-ITT) BS.. 2MXV 32-506 O 714
BS.. 2MXV 32-507 O (-ITT) BS.. 2MXV 32-507 O G2 G 2 864 1252 884 738 94 186 706 642 32 365 168 600 625 13 810 959 825 185 334 200
BS.. 2MXV 32-508 O (-ITT) 802
BS.. 2MXV 32-510 O (-ITT) 851
BS.. 2MXV 32-512 O (-ITT) 915
BS.. 2MXV 40-904 O (-ITT) BS.. 2MXV 40-904 O 931 711
BS.. 2MXV 40-905 O (-ITT) 931 781
BS.. 2MXV 40-906 O (-ITT) 931 811
BS.. 2MXV 40-907 O (-ITT) G 2 1/2 G 2 1/2 931 1252 884 857 124 238 820 740 40 365 200 600 625 13 810 959 825 185 334 200
BS.. 2MXV 40-908 O (-ITT) 931 887
BS.. 2MXV 40-910 O (-ITT) 931 947
BS.. 2MXV 40-911 O (-ITT) 1012 977
Dimensions not binding to be verified when ordering (1) Anti-vibration pads kit supplied loose as standard
h9f-l6f-l7f= Fixed speed boosting sets
h9v-l6v-l7v= Variable speed boosting sets
h9i-l6i-l7i= I-MAT boosting sets
585
BS. MXV Pressure boosting sets with 1 to 3 Vertical Multi-Stage Pumps
Fixed speed pump or Variable speed pump (frequency converter)
ON
OFF
h9i
h9f
BS.. 2MXV 50-15.. h9v
BS.. 2MXV 50-20.. I-MAT h7
DN 1 - DN 2 DN 1 DN 2
h3 h3
l7i
l7f
n4 n4 w4 lc m7 l7v
a1 a a1 a m4
fg fg l6v-l6f-l6i
Connection
Collettori
TYPE mm
DN1 DN2 h9f h9v h9i h7 h3 fg a a1 n4 w4 lc m4 m7 l6f l6v l6i l7f l7v l7i
BS.. 2MXV 50-1503/A (ITT) 1015 1344 975 934 1080 1220 1110 130 270 145
BS.. 2MXV 50-1504 (ITT) 1015 1344 975 980 1080 1220 1110 130 270 145
BS.. 2MXV 50-1505 (ITT) 1015 1344 975 1028 1080 1220 1110 130 270 145
BS.. 2MXV 50-1506 (ITT) 1015 1344 975 1167 1080 1220 1110 130 270 145
G3 G3 225 913 816 48 550 82 700 950 225 1080 1220 130
BS.. 2MXV 50-1507 (ITT) 1015 1344 1175 1215 1110 270 145
BS.. 2MXV 50-1508/A (ITT) 1420 1344 1175 1263 1170 1220 1110 220 270 145
BS.. 2MXV 50-1509 (ITT) 1420 1344 1175 1311 1170 1220 1110 220 270 145
BS.. 2MXV 50-1510 (ITT) 1420 1344 1175 1359 1170 1220 1110 220 270 145
BS.. 2MXV 50-2003 (ITT) 1015 1344 975 932 1112 1252 1142 130 270 145
BS.. 2MXV 50-2004 (ITT) 1015 1344 975 967 1112 1252 1142 130 270 145
BS.. 2MXV 50-2005 (ITT) 1015 1344 975 1119 1112 1252 1142 130 270 145
G3 G3 225 913 816 48 550 82 700 950 225 1202 1252 220
BS.. 2MXV 50-2006 (ITT) 1420 1344 975 1167 1142 270 145
BS.. 2MXV 50-2007 (ITT) 1420 1344 1175 1215 1202 1252 1142 220 270 145
BS.. 2MXV 50-2008 (ITT) 1420 1648 1175 1367 1202 1202 1142 220 220 145
BS.. 2MXV 50-2009 (ITT) 1420 1648 1175 1415 1202 1202 1142 220 220 145
BS.. 2MXV 65-3202/D (ITT) 1015 1344 975 853 1114 1254 1144 130 270 145
BS.. 2MXV 65-3203/C (ITT) 1015 1344 975 947 1114 1254 1144 130 270 145
BS.. 2MXV 65-3204/C (ITT) 1420 1344 975 993 1204 1254 1154 220 270 145
100 100 240 1310 1090 110 550 231 750 950 200 1204 1204 1154 220
BS.. 2MXV 65-3205/D (ITT) 1420 1648 1175 1189 220 145
BS.. 2MXV 65-3206/D (ITT) 1420 1648 1175 1235 1204 1204 1154 220 220 145
BS.. 2MXV 65-3207/D (ITT) 1420 1648 1175 1306 1204 1204 1154 220 220 145
BS.. 2MXV 80-4802/C (ITT) 1015 1344 975 940 1080 1220 1110 130 270 145
BS.. 2MXV 80-4803/C (ITT) 1420 1344 975 1001 1170 1220 1110 220 270 145
BS.. 2MXV 80-4804/D (ITT) 1420 1648 1175 1212 1170 1170 1120 220 220 145
125 125 240 1441 1191 125 550 279 750 950 200 1170 1170 1120 220
BS.. 2MXV 80-4805/D (ITT) 1420 1648 1175 1299 220 145
BS.. 2MXV 80-4806/D (ITT) 1420 1648 1175 1360 1170 1170 1120 220 220 145
BS.. 2MXV 80-4807/E (ITT) 1420 * 1175 1498 1170 * 1120 220 * 145
BS.. 2MXV 100-6501-ITT 1302
BS.. 2MXV 100-6502-2R (ITT) 1394
BS.. 2MXV 100-6502 (ITT) 1534
BS.. 2MXV 100-6503-2R (ITT) 1651
* * * 142,5 * * 950 * * * * * *
BS.. 2MXV 100-6503/A (ITT) * * * 1705 * *
150 150 1797
BS.. 2MXV 100-6504-2R/A (ITT)
BS.. 2MXV 100-6504 (ITT) 1797
BS.. 2MXV 100-6505-2R 1968
BS.. 2MXV 100-6505 1968
BS.. 2MXV 100-9001-1R-ITT 1306
BS.. 2MXV 100-9001-ITT 1306
BS.. 2MXV 100-9002-2R (ITT) 1538
BS.. 2MXV 100-9002 (ITT) 1563
BS.. 2MXV 100-9003-2R/A (ITT) 200 200 * * * 1709 370 1883 1543 170 1050 260 950 1300 360 * * * * * *
BS.. 2MXV 100-9003 (ITT) 1709
BS.. 2MXV 100-9004-2R 1904
BS.. 2MXV 100-9004 1904
BS.. 2MXV 100-9005-2R 1997
Dimensions not binding to be verified when ordering * Dimensions on request h9f-l6f-l7f= Fixed speed boosting sets
h9v-l6v-l7v= Variable speed boosting sets
h9i-l6i-l7i= I-MAT boosting sets
586
BS. MXV Pressure boosting sets with 1 to 3 Vertical Multi-Stage Pumps
Fixed speed pump or Variable speed pump (frequency converter)
h9v
h9f
h9i
I-MAT
h7
DN 2
DN 1
h2
h3
n4 w4 lc m7
a1 a a1 m4 l7v-l7f-l7i
fg l6v-l6f-l6i
Connection
Collettori
TYPE mm
DN 1 DN 2 h9f h9v h9i h7 h3 h2 fg a a1 n4 w4 lc m4 m7 l6f l6v l6i l7f l7v l7i
BS.. 3MXV 25-304 O (-ITT) 1357 771
BS.. 3MXV 25-305 O (-ITT) 1357 795
BS.. 3MXV 25-306 O (-ITT) 1357 819
BS.. 3MXV 25-307 O (-ITT) G2 G2 969 1357 989 843 199 279 657 593 32 476 84 950 1000 25 1195 1334 1200 195 334 200
BS.. 3MXV 25-308 O (-ITT) 1449 867
BS.. 3MXV 25-310 O (-ITT) 1449 916
BS.. 3MXV 25-312 O (-ITT) 1449 1004
BS.. 3MXV 32-504 O (-ITT) 1357 771
BS.. 3MXV 32-505 O (-ITT) 1357 795
BS.. 3MXV 32-506 O (-ITT) 1449 819
BS.. 3MXV 32-507 O (-ITT) G 2 1/2 G 2 1/2 969 1449 989 843 199 299 730 650 40 476 113 950 1000 25 1195 1334 1200 195 334 200
BS.. 3MXV 32-508 O (-ITT) 1449 907
BS.. 3MXV 32-510 O (-ITT) 1449 956
BS.. 3MXV 32-512 O (-ITT) 1449 1020
BS.. 3MXV 40-904 O (-ITT) 816
BS.. 3MXV 40-905 O (-ITT) 886
BS.. 3MXV 40-906 O (-ITT) 916
BS.. 3MXV 40-907 O (-ITT) G3 G3 969 1449 989 962 229 349 842 746 48 476 145 950 1000 25 1195 1334 1200 195 334 200
BS.. 3MXV 40-908 O (-ITT) 992
BS.. 3MXV 40-910 O (-ITT) 1052
BS.. 3MXV 40-911 O (-ITT) 1082
Dimensions not binding to be verified when ordering (1) Anti-vibration pads kit supplied loose as standard
h9f-l6f-l7f= Fixed speed boosting sets
h9v-l6v-l7v= Variable speed boosting sets
h9i-l6i-l7i= I-MAT boosting sets
587
BS. MXV Pressure boosting sets with 1 to 3 Vertical Multi-Stage Pumps
Fixed speed pump or Variable speed pump (frequency converter)
ON
OFF
h9i
h9f
h9v
I-MAT h7
DN 1 DN 2
h3
l7i
l7f
n4 w4 lc m7 l7v
a1 a m4
fg l6v-l6f-l6i
Connection
Collettori mm
TYPE
DN1 DN2 h9f h9v h9i h7 h3 fg a a1 n4 w4 lc m4 m7 l6f l6v l6i l7f l7v l7i
BS.. 3MXV 50-1503/A (ITT) 1020 1408 1040 1005 1572 1652 1577 140 220 145
BS.. 3MXV 50-1504 (ITT) 1020 1408 1040 1051 1572 1652 1577 140 220 145
BS.. 3MXV 50-1505 (ITT) 1020 1408 1040 1099 1572 1652 1577 140 220 145
BS.. 3MXV 50-1506 (ITT) 1220 1408 1240 1239 1572 1652 1577 140 220 145
100 100 1220 1408 1240 1287 296 1100 880 110 550 94 1200 1400 200 1572 1652 1577 140
BS.. 3MXV 50-1507 (ITT) 220 145
BS.. 3MXV 50-1508/A (ITT) 1408 * 1240 1335 1652 1652 1577 220 220 145
BS.. 3MXV 50-1509 (ITT) 1408 * 1240 1382 1652 1652 1577 220 220 145
BS.. 3MXV 50-1510 (ITT) 1408 * 1240 1430 1652 1652 1577 220 220 145
BS.. 3MXV 50-2003 (ITT) 1020 1408 1040 1003 1572 1652 1577 140 220 145
BS.. 3MXV 50-2004 (ITT) 1020 1408 1040 1038 1572 1652 1577 140 220 145
BS.. 3MXV 50-2005 (ITT) 1020 1408 * 1190 1572 1652 1577 140 220 145
100 100 1408 * 1240 1238 296 1100 880 110 550 94 1200 1400 200 1572 1652 1577 140
BS.. 3MXV 50-2006 (ITT) 220 145
BS.. 3MXV 50-2007 (ITT) 1408 * 1240 1286 1572 1652 1577 140 220 145
BS.. 3MXV 50-2008 (ITT) * * * 1438 1652 QA 1577 220 QA 145
BS.. 3MXV 50-2009 (ITT) * * * 1486 1652 QA 1577 220 QA 145
BS.. 3MXV 65-3202/D (ITT) 1500 1593 1020 903 1574 1654 1579 140 220 145
BS.. 3MXV 65-3203/C (ITT) 1500 1593 1020 997 1574 1654 1579 140 220 145
BS.. 3MXV 65-3204/C (ITT) 1500 1593 1020 1043 1574 1654 1579 140 220 145
125 125 1713 QA 1220 1239 291 1406 1156 125 550 284 1200 1400 200 1654 QA 1579 220
BS.. 3MXV 65-3205/D (ITT) QA 145
BS.. 3MXV 65-3206/D (ITT) 1713 QA 1220 1285 1654 QA 1579 220 QA 145
BS.. 3MXV 65-3207/D (ITT) 1713 QA 1388 1356 1654 QA 1704 220 QA 270
BS.. 3MXV 80-4802/C (ITT) 1500 1593 1020 990 1577 1657 1582 140 220 145
BS.. 3MXV 80-4803/C (ITT) 1500 1593 1020 1051 1577 1657 1582 140 220 145
BS.. 3MXV 80-4804/D (ITT) 1713 QA 1220 1262 1657 QA 1582 220 QA 145
150 150 1713 QA 1388 1349 291 1525 1240 142,5 550 313 1200 1400 200 1657 QA 1707 220
BS.. 3MXV 80-4805/D (ITT) QA 270
BS.. 3MXV 80-4806/D (ITT) 1713 QA 1388 1410 1657 QA 1707 220 QA 270
BS.. 3MXV 80-4807/E (ITT) 1713 QA 1388 1548 * QA 1707 * QA 270
BS.. 3MXV 100-6501-ITT 1322
BS.. 3MXV 100-6502-2R (ITT) 1414
BS.. 3MXV 100-6502 (ITT) 1554
BS.. 3MXV 100-6503-2R (ITT) 1671
200 200 * * * 1725 386 1658 1318 170 900 65 1500 1650 175 * * * * * *
BS.. 3MXV 100-6503/A (ITT)
BS.. 3MXV 100-6504-2R/A (ITT) 1817
BS.. 3MXV 100-6504 (ITT) 1817
BS.. 3MXV 100-6505-2R 1988
BS.. 3MXV 100-6505 1988
BS.. 3MXV 100-9001-1R-ITT 1326
BS.. 2MXV 100-9001-ITT 1326
BS.. 3MXV 100-9002-2R (ITT) 1558
BS.. 3MXV 100-9002 (ITT) 1583
BS.. 3MXV 100-9003-2R/A (ITT) 200 200 * * * 1729 390 1901 1561 170 1050 280 1500 1850 360 * * * * * *
BS.. 3MXV 100-9003 (ITT) 1729
BS.. 3MXV 100-9004-2R 1924
BS.. 3MXV 100-9004 1924
BS.. 3MXV 100-9005-2R 2017
Dimensions not binding to be verified when ordering * Dimensions on request h9f-l6f-l7f= Fixed speed boosting sets
h9v-l6v-l7v= Variable speed boosting sets
QA Cabinet version
h9i-l6i-l7i= I-MAT boosting sets
588
BS. 2NG... Systems with two self-priming Jet pumps
Fixed speed pump
Coverage chart
0 U.S. g.p.m. 40 60 80
70
60 200
50
H 150
m ft
40
2NG
2NGL
30 2NGX 100
20
50
10
0 3
m /h 8 12 16 20
0 Q l/min 100 200 300
Construction
Automatic pressure boosting plant consisting of two pumps complete with ball, non return valve on the suction side and ball valves on the discharge
side.
Suction and delivery manifolds are in AISI 304 stainless steel.
Connections are located on the delivery manifold for the installation of two 20/24 litres vessels.
Electrical control boards:
- with microprocessor for fixed speed pump units.
The unit includes one pressure gauge and two adjustable differential pressure switches.
Operation
BS 2F Fixed speed pump
Depending on the reduction of the pressure in the system, the pressure switches determine the starting up of the pumps in sequence and the
microprocessor alternates the starts.
Applications
For drawing water out a well.
As pressure boosting pump to increase water pressure when needed (follow local rules).
Motors
2-pole induction motors, 50 Hz, n ≈ 2900 rpm.
- Three-phase 230/400V ± 10%, suitable for operation with frequency converter;
- Single-phase 230 V ± 10%, with thermal protector.
Insulation class F.
Protection IP 54.
Constructed in accordance with: IEC 60034.
Other voltages and frequencies on request.
589
BS. 2NGL, 2NG Systems with two self-priming Jet pumps
Fixed speed pump
Coverage chart
50 50
H H
m NGL 2/80 m NGL 3/100
40 40
30 30
20 20
10 10
0 m3/h 2 3 4 5 6 7 0 m3/h 2 3 4 5 6 7
Q Q
0 l/min 20 40 60 80 100 0 l/min 20 40 60 80 100
72.1146.2 72.1146.2
50 60
H
m NGL 4/110 H
40 m NG 3
30 40
20
10 20
0 m3/h 2 4 6 8 10 0 m3 /h 1 2 3 4 5 6
0
Q
l/min 50 100 150 Q
0 l/min 20 40 60 80 100
72.1146.3 72.954.3C
50 70
H
H
m NG 4 m NG 5/16
50
30
40
15 30
0 m3 /h 2 4 6 8 0 m3 /h 2 4 6 8 10
0
Q l/min 40 80 120
Q
0 l/min 50 100 150
72.954.4C 72.954.5C
60 60
H
m NG 6/22 NG 7/22
50
40 H
m
3 40
30
3 1
1
20 30
0 m3 /h 5 10 15 20 0 m3 /h 5 10 15 20
0 Q l/min 100 200 300 0 Q l/min 100 200 300
72.954.6C 72.954.7C
590
BS. 2NGX Systems with two self-priming Jet pumps
Fixed speed pump
Coverage chart
50 50
H H
m NGX 2/80 m NGX 3/100
40 40
30 30
20 20
10 10
0 m3/h 2 3 4 5 6 7 0 m3/h 2 3 4 5 6 7
Q Q
0 l/min 20 40 60 80 100 0 l/min 20 40 60 80 100
72.1146.2 72.1146.2
50 60
H
m NGX 4/110 H
40 m NGX 4/16
30 40
20 30
10 20
0 m3/h 2 4 6 8 10 0 m3 /h 2 4 6 8 10
Q Q
0 l/min 50 100 150 0 l/min 50 100 150
72.1146.3 72.1146.4
60
H
m NGX 6/22
40
30
20
0 m3 /h 5 10 15 20
0 Q l/min 100 200 300
72.1146.5
591
BS. 2NG... Systems with two self-priming Jet pumps
Fixed speed pump
L2 DN 2
DN 1
h2
h1
3.93.044
(1) m1
L1 B2
BS2F BSM2F
Mains: 400V 3~ Mains: 230V 1~ Motor Q Vessel
3~ max* Pres. switch setting Connection mm Weight Mem. Vessel
Motor: 400V 3~ Motor: 230V 1~
kW HP l/min bar bar DN1 DN2 H h1 h2 L1 L2 m1 B2 B kg litre litre
BS2F 2NGL 2/80 BSM2F 2NGLM 2/80 0,55+0,55 0,75+0,75 100 2,4÷3,6 2,0÷3,2 G2 G 11/2 840 151 206 793 355 42 24x2 100
BS2F 2NGL 3/100 BSM2F 2NGLM 3/100 0,65+0,65 0,9+0,9 110 2,8÷4,0 2,4÷3,6 G2 G 11/2 840 151 206 793 355 235 625 600 46 24x2 100
BS2F 2NGL 4/110 BSM2F 2NGLM 4/110 0,75+0,75 1+1 150 2,4÷3,6 2,0÷3,2 G2 G 11/2 840 151 206 793 355 49 24x2 100
* Maximum pumps flow at minimum set pressure of 2 nd pressure switch. Dimensions not binding to be verified when ordering
BS2F BSM2F
Q Vessel
Mains: 400V 3~ Mains: 230V 1~ Motor Pres. switch setting Connection mm
3~ 1~ max* Weight Mem. Vessel
Motor: 400V 3~ Motor: 230V 1~
kW HP l/min bar bar DN1 DN2 H h1 h2 L1 L2 m1 B2 B kg litre litre
BS2F 2NG 3/A BSM2F 2NGM 3/A 0,55+0,55 0,75+0,75 95 3,0÷4,2 2,5÷3,7 G2 G 11/2 840 184 188 775 345 61 24x2 100
BS2F 2NG 4/B BSM2F 2NGM 4/A 0,75+0,75 1+1 130 2,4÷3,6 2,0÷3,2 G2 G 11/2 840 184 188 775 345 62 24x2 100
BS2F 2NG 5/16/A BSM2F 2NGM 5/16E 1,1+1,1 1,5+1,5 140 3,8÷5,3 3,4÷4,9 G 21/2 G 11/2 840 200 202 935 470 24x2 100
235 625 600 86
BSM2F 2NGM 6/22E 1,5+1,5 2+2 290 3,0÷4,2 2,5÷3,7 G 21/2 G 11/2 840 200 202 935 470 89 100 200
BS2F 2NG 6/22/A 1,5+1,5 2+2 290 3,2÷4,5 2,8÷4,0 G 21/2 G 11/2 840 200 202 935 470 90 100 200
BS2F 2NG 7/22/B 2,2+2,2 3+3 300 3,8÷5,3 3,4÷4,9 G 21/2 G 11/2 840 200 202 935 470 92 200 300
* Maximum pumps flow at minimum set pressure of 2 nd pressure switch. Dimensions not binding to be verified when ordering
L2
DN 2
Hv
Hf
DN 1
h2
h1
4.93.315
m1
(1)
L1 B2
BS2F BSM2F
Mains: 400V 3~ Mains: 230V 1~ Motor Q Vessel
3~ max* Pres. switch setting Connection mm Weight Mem. Vessel
Motor: 400V 3~ Motor: 230V 1~
kW HP l/min bar bar DN1 DN2 H h1 h2 L1 L2 m1 B2 B kg litre litre
BS2F 2NGX 2/80 BSM2F 2NGXM 2/80 0,55+0,55 0,75+0,75 100 2,4÷3,6 2,0÷3,2 G2 G 11/2 840 151 206 793 355 42 24x2 100
BS2F 2NGX 3/100 BSM2F 2NGXM 3/100 0,65+0,65 0,9+0,9 110 2,8÷4,0 2,4÷3,6 G2 G 11/2 840 151 206 793 355 46 24x2 100
BS2F 2NGX 4/110 BSM2F 2NGXM 4/110 0,75+0,75 1+1 150 2,4÷3,6 2,0÷3,2 G2 G 11/2 840 151 206 793 355 235 625 600 49 24x2 100
BS2F 2NGX 4/16 BSM2F 2NGXM 4/16 1,1+1,1 1,5+1,5 130 3,4÷4,9 3,0÷4,5 G2 G 11/2 840 187 212 836 380 61 24x2 100
BS2F 2NGX 6/22/A BSM2F 2NGXM 6/22 1,5+1,5 2+2 280 3,0÷4,2 2,5÷3,7 G2 G 11/2 840 187 212 836 380 65 100 200
* Maximum pumps flow at minimum set pressure of 2 nd pressure switch. Dimensions not binding to be verified when ordering
592
BS. 4SDP. EMT Pressure boosting sets with one submersible borehole
pump with EASYMAT frequency converter
Coverage chart
3 4 5 U.S. g.p.m. 10 20 30 40
2 3 4 5 Imp. g.p.m. 10 20 30
200
H 500
m
400
100
300
200
1SDP
50
H
40 ft
30 100
20
50
40
10
30
20
5
0.5 m3/h 1 2 3 4 5 10
10 Q l/min 20 30 40 50 100 150
72.1002/N
Operation
BS1V Pressure boosting sets with 1 variable speed pump (with EASYMAT).
Depending on water consumption, one pump is activated, at variable speed, in order to guarantee the quantity of water required at the set
pressure.
Execution
Constant pressure boosting sets with EASYMAT frequency converter made of 1 pump, ball valve, non return valve and pressure gauge on delivery
side.
Suitable for installation of pressure vessel on delivery side.
Applications
For drawing water out of a well
As pressure boosting pump for central water systems with low pressure (follow local specifications if increasing network pressure)
Motors
2-pole induction motors, 50Hz, n ≈ 2900 rpm, suitable for operation with frequency converter
- Three-phase 230V +/-10%
Class F insulation
IP 68 protection
Execution according IEC 60034
Other voltages on demand
593
BS. 4SDP. EMT Pressure boosting sets with one submersible borehole
pump with EASYMAT frequency converter
Coverage chart
0 0 0 0
0 m3/h 1 2 3 3,6 0 m3/h 1 2 3 4 5
Q l/min 0 Q l/min 20 30 40 50 60 70 80
0 20 30 40 50 60
7 7
40 40
5
100 100
20 20
Aliment.: 1 ~ 230 V
Motore: 3 ~ 230 V P2
aliment. motore
A A kW HP DN
DN
BSM1V 14SDP 2/5-EMT 2.5 1.9 0,37 0,5 Rp 1" 1/4
BSM1V 14SDP 2/7-EMT 2.5 1.9 0,37 0,5 Rp 1" 1/4
BSM1V 14SDP 2/10-EMT 3.7 2.8 0,55 0,75 Rp 1" 1/4
BSM1V 14SDP 2/14-EMT 4.8 3.5 0,75 1 Rp 1" 1/4 190 190
BSM1V 14SDP 3/5-EMT 2.5 1.9 0,37 0,5 Rp 1" 1/4
BSM1V 14SDP 3/8-EMT 3.7 2.8 0,55 0.75 Rp 1" 1/4
BSM1V 14SDP 3/11-EMT 4.8 3.5 0,75 1 Rp 1" 1/4
BSM1V 14SDP 3/16-EMT 6.8 4.9 1,1 1.5 Rp 1" 1/4
BSM1V 14SDP 4/5-EMT 2.5 1.9 0,37 0.5 Rp 1" 1/4 G 1 1/4
BSM1V 14SDP 4/7-EMT 3.7 2.8 0,55 0.75 Rp 1" 1/4
BSM1V 14SDP 4/9-EMT 4.8 3.5 0,75 1 Rp 1" 1/4
547
Ø 96
594
03/2021
595
EJ, DJ, EDJ
UNI-EN 12845 fire-fighting systems
EJ 11
UNI-EN 12845 units with 1 N series electric main pump
EJ 21
UNI-EN 12845 units with 2 N series electric main pumps
DJ 11
UNI-EN 12845 units with 1 N series main pump (diesel motor)
EDJ 21
UNI-EN 12845 units with 2 N series main pumps
(electric and diesel motors)
Construction
13
11 10 6
7
5
9
8
4
14 15
12
SERBATOIO
GASOLIO
16
2 3 1
1) Main pump (with diesel motor) 11) Electric control panel (one for each pump)
2) Main pump (with electric motor) 12) Pressure switch for "pump running" signal, re cycling water connection
3) Jockey pump and 0-16 bar glycerine filled pressure gauge.
4) Non-return valve 13) 20-lt PN 16 membrane pressure tank
5) Lockable valve 14) Compensating joint for vibration damping
6) Ball valve 15) Diesel tank оп а separate pedestal (6 hour autonomy)
7) Delivery manifold 16) Painted steel skid
8) Sprinkler connection for protection of pump room
9) Starting system for main pump composed bу two pressure switches, All the butterfly valves or ball valve are locked in the normal position by
one 0-16 bar glycerine filled pressure gauge, ball valve, by-pass circuit. means of a lock and key.
10) Start-Stop system for jockey pump composed bу one pressure switche On request: anti-vibration couplings in both the suction and delivery sec-
and one 0-16 bar glycerine filled pressure gauge. tions.
596
EJ, DJ, EDJ
UNI-EN 12845 fire-fighting systems
Motors The following devices are located on the internal door panel:
Two-pole induction type, 50 Hz, n = 2,900 rpm - Line-sectioning handle - Voltmeter and ammeter on display
Three-phase 230/400V ± 10% up to 3 kW - “Manual-0-Automatic” selector with extractible key only in
400/690V ± 10% 4 kW and higher. “automatic” position - Start/Stop pushbuttons - Pilot lights to indicate:
Insulation class F no-volt, pump running, pump stops, low-pressure.
Protection IP 55.
Construction in accordance with: IEC 60034 Electric main-pump box (diesel motor)
Other voltage and frequency ratings available on request This cabinet contains the electronic control devices for the control of
the diesel motor and the battery chargers for feeding the starter
Diesel motors (for standardised N-series pumps) accumulators.
These are direct-injection pumps fitted with electric control box, fuel The following devices are located on the front of the box:
tank, starter batteries and silencer. - Line-sectioning handle.
- Front panel of the electronic unit.
- Manual-0-Automatic selector with extractible key only an “automatic”
Designation of units position.
597
EJ
UNI-EN 12845 fire-fighting systems
100
300
H
m
N 40-250 N 50-250 N 65-250 N 80-250 N 100-250
200
50 H
N 32L-200 ft
N 32-200 N 50-200 N 65-200 N
40 N 40-200 80-200
N 100-200
30 100
N 32-160 N 32L-160
N 50-160 N 65-160 90
N 40-160 80
N 80-160
70
20
60
50
15 3
5 6 7 8 9 10 m /h 20 30 40 50 100 200 300 400 500
Q
100 150 l/min 300 400 500 1000 2000 3000 4000 5000 8000
72.844.N
60 80 100 U.S. g.p.m. 200 400 600 800 1000 2000 4000
130
400
100
300
H
m
N 40-250 N 50-250 N 65-250 N 80-250 N 100-250
200
50 H
N 32L-200 ft
N 32-200 N 50-200 N 65-200 N
40 N 40-200 80-200
N 100-200
30 100
N 32-160 N 32L-160
N 50-160 N 65-160 90
N 40-160 80
N 80-160
70
20
60
50
15 3
10 20 m /h 40 60 80 100 200 400 600 800 1000
Q
200 300 l/min 600 800 1000 2000 4000 6000 8000 10000 16000
72.844.N
When two pumps are installed, each one shall be capable of providing the specified flows and pressures independently.
When three pumps аге installed, each pump shall bе сараblе of providing at least 50% of the specified flow at the specified pressure.
598
DJ, EDJ
UNI-EN 12845 fire-fighting systems
Accessories
ECCENTRICS REDUCTIONS TYPE
TIPO DNA DNB
RE50-65 DN50 DN65
RE50-80 DN50 DN80
RE50-100 DN50 DN100
RE50-125 DN50 DN125
RE65-80 DN65 DN80
DNA RE65-100 DN65 DN100
DNB RE65-125 DN65 DN125
RE65-150 DN65 DN150
RE65-200 DN65 DN200
RE80-100 DN80 DN100
RE80-125 DN80 DN125
RE80-150 DN80 DN150
RE80-200 DN80 DN200
RE80-250 DN80 DN250
RE100-150 DN100 DN150
RE100-200 DN100 DN200
Flanged reductions eccentric to be installed in the suction of main pumps, are complete of ¼” out RE100-250 DN100 DN250
point, ball interception valve and vacuum gauge (or gauge on request). To choice it take the RE125-200 DN125 DN200
diameter inlet of the main pumps DNA (limit of standard) and then consult the following tables in RE125-250 DN125 DN250
order to define the enlargement of the eccentric cone DNB (depending on the type of installation: RE125-300 DN125 DN300
suction lift or positive head). RE150-250 DN150 DN250
RE150-300 DN150 DN300
Clarification: the previous tables suggest only indications concerning the maximum permissible RE150-350 DN150 DN350
speed in suction of main pumps, that choice may not be enough because the standard EN 12845 RE150-400 DN150 DN400
requires also that the suction piping, including all valves and fittings, shall be designed in such a RE200-300 DN200 DN300
way a sto ensure that the available NPSH at the pump inlet exceeds the required NPSH by at least RE200-350 DN200 DN350
1 mt at the maximum pump flow as shown in table 14 of the EN 12845 norm. RE200-400 DN200 DN400
SUCTION Velocità
LIFT INSTALLATION Water Speed (V≤ 1,5 m/s)
Acqua (V≤ 1,5 m/s)
Q (l/m) 0÷452 453÷706 707÷1103 1104÷1589 1590÷2824 2825÷4413 4414÷6355 6356÷8650 8651÷11299
Ø min DN80 DN100 DN125 DN150 DN200 DN250 DN300 DN350 DN400
TYPE
TIPO DN
CE-50 DN50 PN16
CE-65 DN65 PN16
CE-80 DN80 PN16
CE-100 DN100 PN16
CE-125 DN125 PN16
CE-150 DN150 PN16
CE-200 DN200 PN16
CE-250 DN250 PN16
CE-300 DN300 PN16
CE-350 DN350 PN16
CE-400 DN400 PN16
In presence of diesel motorpump is recommended to install on suction an elastic anti-vibration compensator to dampen the vibrations (in the delivery of
the pump is already present). By inserting a compensator between two manifolds you can connect each two fire fighting modules.
599
EJ, DJ, EDJ
UNI-EN 12845 fire-fighting systems
Accessories
INTERCEPTION BUTTERFLY VALVES “LUG” TYPE
TYPE
TIPO DN
LUG-50 DN50
LUG-65 DN65
LUG-80 DN80
LUG-100 DN100
LUG-125 DN125
LUG-150 DN150
LUG-200 DN200
LUG-250 DN250
LUG-300 DN300
LUG-350 DN350
LUG-400 DN400
Interception butterfly valve LUG type, with threaded ears, complete with operating lever up to DN100 and hand-wheel for larger diameters
KIT FLOWMETER
L Flowmeter
Flussimetro Fondo scala
Full scale Collegamenti
Connections L H
TYPE
TIPO (m3/h) DNM DNV (mm) (mm)
KM-65-40 T40 55 DN65 DN40 412 452
KM-65-50 T50 90 DN65 DN50 465 452
COLLETTORE
KM-80-65 T65 140 DN80 DN65 540 460
DI MANDATA
H KM-100-80 T80 200 DN100 DN80 635 470
KM-125-100 T100 280 DN125 DN100 770 485
DNM
DNV
Kit of connection between the fire fighting delivery manifold and the flow meter, composed by: interception valve, steel galvanized socket with adequate
length and flowmeter. In the case of flanged composition is also supplied with the counter-flange to be inserted after the flowmeter, with two black
rubber gaskets and bolts for fixing the flowmeter. Please note that is necessary the insertion after the flowmeter of another interception valve for
adjusting the water flow.
Tipo RA 12845 (no. 4 alarm input “Level A” and no. 12 alarm inputs “level B”)
- Features: Electronic control panel for alarm signalling
- Input voltage 1 ~ 50/60Hz 230V±10%
RA 12845 - Transformer 230 V/24 V for auxiliary circuit
- Nr.4 very low voltage input from free NC contact for alarm fire “level A” (at the opening of the
NC contact the red flashing light and the buzzer activate)
- Nr.12 very low voltage input from free NC contact for alarm breakdown “level B” (when opening
the NC contact the yellow flashing light and the buzzer activate)
- Nr.1 very low voltage input from free NO contact for alarm breakdown “Level B” (when closing
the NO contact the yellow flashing light and the buzzer activate)
- Green light for power on
- Red light for “alarm”
- Red light for “beacon excluded”
- Pushbutton “test” for temporary activation of the beacon
- Pushbutton “reset” for manual restoration of the alarm
- Pushbutton “beacon activation” for the activation of the acoustic alarm
- Pushbutton “beacon exclusion” for the exclusion of the acoustic alarm
- Internal selector for selecting the alarm restoration mode (automatic-manual)
- Internal selector for activation of the timer for automatic switch-off of the beacon
- Trimmer for automatic switch-off time delay selection (from 25” to 120”)
- Alarm beacon 90dB 12Vcc
- Sealed internal battery for back-up 12Vcc 1,2Ah
- Auxiliary protection fuse
- Battery protection fuse
- General alarm output with exchangeable contact (max 5A 250V AC1)
- Red flashing light 12Vcc; Yellow flashing light 12Vcc
- Box in thermoplastic material
- Output with cable holder
- Protection IP55; Ambient temperature: -5/+40 °C
600
03/2021
QM, QT
Control panels
601
Index
Supply No. pumps Application
Submersible
Bore-hole
Surface
TYPE
1~ 3~ 1 2 3 4
QM ✓ ✓ ✓ ✓
M COMP ✓ ✓ ✓ ✓
PFC-M ✓ ✓ ✓
QML/A 1 D ✓ ✓ ✓ ✓
T COMP ✓ ✓ ✓
PFC-T ✓ ✓ ✓
QTL/A 1 D ✓ ✓ ✓ ✓ ✓
QTL 1 D FTE ✓ ✓ ✓ ✓
QTL/A 1 ST FT ✓ ✓ ✓ ✓
QTL/A 1 ST FT-RH ✓ ✓ ✓
QTL 1 ST FTE ✓ ✓ ✓ ✓
QTL 1 SS E ✓ ✓ ✓ ✓
QTL 1 IS FTE ✓ ✓ ✓
QML/A 2 D ✓ ✓ ✓ ✓
QTL/A 2 D ✓ ✓ ✓
QTL/A 2 ST FT ✓ ✓ ✓
QTL/A 2 ST FT-RH ✓ ✓ ✓
QML/A 3 D ✓ ✓ ✓
QTL/A 3 D ✓ ✓ ✓ ✓
QTL/A 3 ST FT ✓ ✓ ✓
QTL/A 3 ST FT-RH ✓ ✓ ✓
QML 1 VFT ✓ ✓ ✓ ✓
QTL 1 VFT ✓ ✓ ✓ ✓
QML 2 VFT ✓ ✓ ✓
QTL 2 VFT ✓ ✓ ✓
QML 1.1 VFT ✓ ✓ ✓
QTL 1.1 VFT ✓ ✓
QML 3 VFT ✓ ✓ ✓
QTL 3 VFT ✓ ✓ ✓
QTL 1.2 VFT ✓ ✓ ✓
QTL 4 VFT ✓ ✓ ✓
QTL 1.3 VFT ✓ ✓ ✓
602
Power Rotation speed Starting Typology
Electromechanical
Impedance stator
Variable speed
Fixed Speed
Electronic
Soft start
D.O.L.
page
Y/∆
kW
603
Control panels
QM Control panel for 1 pump with single-phase motor, direct starting
Construction Components
Control panel with ON-OFF switch and capacitor, for 1 pump with - Thermoplastic case.
single-phase motor without built-in capacitor. - ON-OFF switch with lamp
- Capacitor
- Terminal board
Technical data - Cable glands
- Mains single-phase 230V ±10% 50/60 Hz
(other voltages on request).
- Ambient temperature from -5 °C to +40 °C.
- Protection IP 55.
Construction Components
Control panel with ON-OFF switch, circuit breaker and capacitor, for 1 - Thermoplastic case.
submersible pump with single-phase motor without built-in capacitor. - ON-OFF switch with lamp
- Thermal device
- Capacitor
Technical data - Terminal board
- Mains single-phase 230V ±10% 50/60 Hz - Cable glands
(other voltages on request).
- Ambient temperature from -5 °C to +40 °C.
- Protection IP 55.
604
Control panels
M COMP Control panel for 1 pump with single-phase motor, direct starting
Protector Capacitor Motor 230V - 1~ Dimensions
Code Type
max A 450Vc kW HxBxP mm
44020000000 M COMP 4-16 4,5 16 μF 0,37 220x210x110
44020001000 M COMP 4-20 4,5 20 μF 0,55 220x210x110
44020010000 M COMP 5-20 5 20 μF 0,55 220x210x110
44020011000 M COMP 5-25 5 25 μF 0,55 220x210x110
44020021000 M COMP 6-20 6 20 μF 0,75 220x210x110
44020023000 M COMP 6-35 6 35 μF 0,75 220x210x110
44020031000 M COMP 7-25 7 25 μF 0,9 220x210x110
44020032000 M COMP 7-30 7 30 μF 0,9 220x210x110
LVBT 44020040000 M COMP 8-25 8 25 μF 1,1 220x210x110
44020041000 M COMP 8-30 8 30 μF 1,1 220x210x110
44020052000 M COMP 10-35 10 35 μF 1,1 220x210x110
44020053000 M COMP 10-40 10 40 μF 1,1 220x210x110
44020060000 M COMP 12-35 12 35 μF 1,5 220x210x110
44020062000 M COMP 12-50 12 50 μF 1,5 220x210x110
44020063000 M COMP 12-60 12 60 μF 1,5 220x210x110
44020081000 M COMP 16-70 16 70 μF 2,2 220x210x110
Construction Components
Control panel with ON-OFF switch and capacitor for 1 pump with single- - Thermoplastic case.
phase motor. - ON-OFF switch with pilot lamp with thermal protector.
Suitable for use with LVBT board for level control. - Capacitor.
Protection is provided by means of a main bi-polar switch with a phase. - Terminal board.
protected against overload by means of a thermal element. - Terminals for LVBT board for level control.
- In/Out cable glands.
Technical data
- Mains single-phase 230V ±10% 50/60 Hz (other voltages on request).
- Ambient temperature from -5 °C to +40 °C.
- Protection IP 44. On request:
- Control through pressure switch (pressure booster set). - LVBT card for level control.
- Control through float switch (for filling a tank).
A 450Vc kW HxBxP mm
PFC-M 18-16 1 - 18 16 μF 0,37 220x210x110
PFC-M 18-20 1 - 18 20 μF 0,55 220x210x110
PFC-M 18-25 1 - 18 25 μF 0,55 220x210x110
PFC-M 18-30 1 - 18 30 μF 0,75 220x210x110
PFC-M 18-35 1 - 18 35 μF 0,75 220x210x110
PFC-M 18-40 1 - 18 40 μF 1,1 220x210x110
PFC-M 18-50 1 - 18 50 μF 1,5 220x210x110
PFC-M 18-60 1 - 18 60 μF 1,5 220x210x110
PFC-M 18-70 1 - 18 70 μF 2,2 220x210x110
Construction Setting
Control panel for controlling one pump with single-phase motor. Electronic - Min – Max voltage range.
control of the operation and dry-running protection through the power - Motor rated current.
factor (PF) control. - Power factor (PF) value for dry-running protection.
The installation of level probes into the well is not required. - Up to four programmable restarts in case of no water condition.
It stops the pump in case of lack of air cushion in the pressure vessel
(patented system). Alarms (with pump stop)
Displayed operating data and alarms available in four languages. - Mains failure.
- Undervoltage and overvoltage.
Technical data - Motor overload.
- Mains single-phase 230V ±10% 50/60 Hz. - No water.
- Max output current: 18 A. - No air cushion in the pressure vessel.
- Ambient temperature from -5 °C to +40 °C.
- Relative humidity: from 20% to 90% without condensation Components
- Protection IP 55. - Thermoplastic case. - Capacitor. - Terminal board.
- Control through pressure switch (pressure booster set). - Display : 2x16 characters. - 6 button key board.
- Control through float switch (for filling a tank). - In/Out Cable glands.
- Alarm output signal.
- Constructed in accordance with: IEC/EN 60439-1. On request: - RA 100 control panel for remote alarm.
605
Control panels
QML/A 1 D Control panel for 1 pump with single-phase motor, direct starting
Construction Components
Control panel and protection for 1 pump with three-phase motor. - Thermoplastic case.
Arranged for the LVBT level control internal connection against dry - ON-OFF control switch
running (T COMP8 model has the level control as a standard). - Fuse holder - Contactor - Thermal relay
Control pumps with pressure switch and float-type switch. - Fuses for change of voltage: 230 V or 400 V - Transformer
- Terminals for pressure switch or float switch connection
- Terminals for LVBT board (for T COMP 10,12,16,20 models)
- Green LED indicator: voltage ON
Technical data - Red LED indicator: thermic block
- Mains 230V or 400V ±10% 50/60 Hz (other voltages on request). - Cable glands
- Ambient temperature from -5 °C to +40 °C.
- Protection IP 44. ON REQUEST:
LVBT board for level control (for T COMP 10,12,16,20 models)
606
Control panels
PFC-T Control panel for 1 pump with three-phase motor, PF control
Construction Setting
Control panel for controlling 1 pump with three-phase motor. Electronic - Min – Max voltage range
control of the operation and dry-running protection through the power - Motor rated current
factor (PF) control. - Power factor (PF) value for dry-running protection
The installation of level probes into the well is not required. - Up to four programmable restarts in case of no water condition
It stops the pump in case of lack of air cushion in the pressure vessel
Displayed operating data and alarms, available in four languages. Alarms (with pump stop)
- Phase failure - Wrong phase sequence
- Undervoltage and overvoltage
Technical data - Motor overload
- Mains three-phase 400V - 3 ~ ±10% 50/60 Hz - No water
- Output current: 16 A - No air cushion in the pressure vessel
- Ambient temperature from -5 °C to +40 °C.
- Relative humidity: from 20% to 90% without condensation Components
- Protection IP 55. - Thermoplastic case.
- Control through pressure switch (pressure booster set) - Terminal board.
- Control through float switch (for filling a tank) - Display : 2x16 characters. - 6 button key board.
- Alarm output signal - In/Out Cable glands.
- Constructed in accordance with: IEC/EN 60439-1.
On request: - RA 100 control panel for remote alarm.
QTL/A 1 D Control panel for 1 pump with three-phase motor, direct starting
Construction Components
Control panel for 1 pump with three-phase motor, direct starting for - Thermoplastic case (metallic for 7,5-9,2-11kW).
pressure booster sets and submersible drainage pumps. - Door lock master switch.
For pressure booster sets: - Fuses for power line. - Fuses for auxiliary circuit.
- with working time-measuring system that stops the pump in case of lack - Starting contactor and thermal relay (for 7,5-9,2-11kW).
of air cushion in the pressure vessel. - Electronic board type MPS 3000 with microprocessor.
- dry-running protection with float switch or level control probes. - Terminals for pressure trasducer / level probes.
For submersible drainage pumps:
- automatic operating test of the pump every set hours of inactivity (with - Connection terminals for thermal protector.
pump in the automatic operating mode). - Connection terminals for the RA 100 - RA 100A type.
- Pump control with signals coming from: - Terminals for pressure switch connection.
- 2 float switches: one for starting-up and stopping pump, one for the - Terminals for float switch connection against dry-running.
alarm maximum level (optional). - Terminals for remote signals
- 3 float switches: one for starting-up pump, one for stopping the pump - Cable glands.
and one for the alarm maximum level (optional).
Pump operation controlled by an electronic board type MPS 3000 with
microprocessor which allows different modes of operation of the pump. ON REQUEST:
- RA 100 - RA 100A control panel for remote alarm.
Technical data - Volt free contact control panel Q-MSP 9M.
- Mains 400V 3 ~ ±10% 50/60 Hz (other voltages on request).
- Ambient temperature from -5 °C to +40 °C.
- Protection IP 55.
607
Control panels
QTL 1 D FTE Control panel for 1 pump with three-phase motor, direct starting
Construction Components
Electromechanical control panel for 1 pump with three-phase motor, direct - Metal case. - Door lock master switch.
starting. - Power circuit fuses. - Fuses for auxiliary circuit.
Operating signals by E 1000 led card. - Starting contactor. - Thermal relay
Dry-running protection with float switch. - Transformer. - E 1000 led card.
Construction with SRLE level control for probes connection against dry- - Terminals for connection pump operating signal.
running on request . - Terminals for float switch connection against dry-running.
- Cable glands.
QTL/A 1 ST FT Control panel for 1 pump with three-phase motor, Y/Δ starting
Construction Components
Control panel for 1 pump with three-phase motor, Y/Δ starting for - Metal case. - Door lock master switch.
pressure booster sets, with working time-measuring system that stops the - Fuses for power line. - Fuses for auxiliary circuit.
pump in case of lack of air cushion in the pressure vessel. - Starting contactors. - Thermal relay. - Transformer.
Pump operation controlled by an electronic card type MPS 3000 with - Electronic board MPS 3000 with microprocessor.
microprocessor with different pump operating modes. - Terminals for pressure trasducer / level probes.
Dry-running protection with float switch or level control probes. - Connection terminals for thermal protector.
- Connection terminals for the RA 100 - RA 100A type.
- Terminals for motor connection.
- Terminals for connection pressure switch of pump operating.
- Terminals for float switch connection against dry-running.
- Terminals for remote signals
- Cable glands.
Technical data
- Mains 400V 3 ~ ±10% 50/60 Hz (other voltages on request). ON REQUEST:
- Ambient temperature from -5 °C to +40 °C. - RA 100 - RA 100A control panel for remote alarm.
- Protection IP 55. - Voltmeter. - Ammeter.
608
Control panels
QTL/A 1 ST FT-RH Control panel for 1 submersible drainage pump with three-phase motor, Y/Δ starting
Construction Components
Control panel with protection for 1 submersible drainage pump with three-phase - Metal case.
motor, Y/Δ starting. - Line selector switch with door-locking device.
Operation managed by the MPS 3000 electronic circuit board that has the - Power line fuses.
following functions: - Auxiliary circuit fuses. - Contactors.
- automatic operating test of the pump every set hours of inactivity (with - Y/Δ timer. - Thermal relay. - Level regulator.
pump in the automatic operating mode). - MPS 3000 type circuit board with microprocessor.
- Pump control with signals coming from: - Terminals for pressure trasducer / level probes.
- 2 float switches: for starting-up and stopping pump, for the alarm - Connection terminals for thermal protector.
(maximum level is optional). - Connection terminals for the RA 100 - RA 100A type.
- 3 float switches: for starting-up pump, for stopping the pump and for - Connection terminals for float switches or level probes.
the alarm (maximum level is optional). - Connection terminals for water seepages probe.
- Cable glands.
609
Control panels
QTL 1 ST FTE Control panel for 1 pump with three-phase motor, Y/Δ starting
Construction Components
Electromechanical control panel for 1 pump with three-phase motor, Y/Δ - Metal case. - Door lock master switch. - Fuses for power line.
starting. - Fuses for auxiliary circuit. - Starting contactors. - Thermal relay.
Operating signals by E 1000 led board. - Y/Δ timer. - Transformer. - E 1000 led board.
Dry-running protection with float switch. - Terminals for motor connection.
Construction with SRLE level control for probes connection against - Terminals for connection of pump operating signal.
dry-running on request . - Terminals for float switch connection against dry-running.
- Cable glands.
QTL 1 SS E Control panel for 1 pump with three-phase motor, start/stop with soft starter
Construction Components
Control panel for 1 pump with three-phase motor, start/stop with soft starter. - Metal case. - Door lock master switch.
Operating signals on E 1000 led board. - Fuses for power line. - Fuses for auxiliary circuit.
Application: control of submersible motor with great cable length and - Soft starter - Transformer.
surface motors. - By pass contactors (built into the soft starter) - E 1000 led board.
Dry-running protection with float switch. - Terminals for float switch or level probes connection for pump operating.
Construction with SRLE level control for probes connection against dry- - Terminals for float switch or level probes connection against dry-running.
running on request . - Cable glands.
610
Control panels
QTL 1 IS FTE Control panel for 1 pump with three-phase motor, with Stator Impedence starter
Construction Components
Electromechanical control panel for 1 submersible pump with three-phase - Metal case. - Door lock master switch.
motor, with Stator Impedence starter. - Fuses for power line. - Fuses for auxiliary circuit.
Operating signals on led board type E 1000. - Stator Impedence - By pass contactors
Application : submersible motors control with great cable length. - Transformer. - E 1000 led board.
Construction with SRLE level control for probes connection against dry- - RLE level control for connection level probes of pump control.
running . - RLE level control for probes against dry running.
- Terminals for connection level probes or float switch for operating pump.
- Terminals for level probes or float switch connection against dry-running.
Technical data - Cable glands.
- Mains 400V 3 ~ ±10% 50/60 Hz (other voltages on request).
- Ambient temperature from -5 °C to +40 °C. ON REQUEST:
- Protection IP 55. - Voltmeter. - Ammeter.
611
Control panels
QML/A 2 D Control panel for 2 pumps with single-phase motor, direct starting
QTL/A 2 D Control panel for 2 pumps with three-phase motor, direct starting
612
Control panels
QTL/A 2 ST FT Control panel for 2 pumps with three-phase motor, Y/Δ starting
Construction Components
Control panel for 2 pumps with three-phase motor, Y/Δ starting, for - Metal case. - Door lock master switch.
pressure booster sets, with working time-measuring system that stops the - Fuses for power line. - Fuses for auxiliary circuit.
pump in case of lack of air cushion in the pressure vessel. - Starting contactors. - Thermal relay. - Y/Δ timers. - Transformer.
Pump operation cascade mode controlled by an electronic board type - Electronic board type MPS 3000 with microprocessor.
MPS 3000 with microprocessor which allows different operation modes: - Terminals for pressure trasducer / level probes.
- Connection terminals for thermal protector.
Dry-running protection with float switch or level control probes.
- Connection terminals for the RA 100 - RA 100A type.
- Terminals for pressure switch connection.
- Terminals for float switch or float switch connection against dry-running.
Technical data - Terminals for remote signals - Cable glands.
- Mains 400V ±10% 50/60 Hz (other voltages on request).
- Ambient temperature from -5 °C to +40 °C. ON REQUEST:
- Protection IP 55. - Volt free contact control panel Q-MSP 13M.
- RA 100 - RA 100A control panel for remote alarm.
- Voltmeter. - Ammeter.
QTL/A 2 ST FT-RH Electric control panel for 2 drainage pumps with three-phase motor, Y/Δ starting
Construction Components
Control panel with protection for 2 submersible drainage pumps with three- - Metal case.
phase motor, Y/∆ starting. - Door lock master switch.
Operation managed by the MPS 3000 electronic circuit board that has the - Power line fuses.
following functions: - Auxiliary circuit fuses. - Contactors.
- pump changing at every pump start. - Y/∆ timers. - Level regulator.
- working pumps changing after 30 minutes of uninterrupted operation. - Electronic board type MPS 3000 with microprocessor.
- automatic operating test of each individual pump every set hours of - Terminals for pressure trasducer / level probes.
inactivity (with pumps in the automatic functioning mode). - Connection terminals for float switches.
- Pump control with signals coming from: - Connection terminals for thermal protectors.
- 3 float switches: for starting-up and stopping pump 1, for starting-up - Connection terminals for water seepages probe.
and stopping pump 2, for the alarms (maximum level is optional). - Connection terminals for the RA 100, RA 100A type remote alarm
- 4 float switches: for starting-up pump 1, for starting up pump 2, for control panel or volt free contact module.
stopping the pumps and for the alarms (maximum level is optional). - Cable glands.
613
Control panels
QML/A 3 D Control panel for 3 pumps with single-phase motor, direct starting
Construction Components
Control panel for 3 pumps with single-phase motor, direct starting for - Thermoplastic case.
pressure booster sets, with working time-measuring system that stops the - Door lock master switch.
pump in case of lack of air cushion in the pressure vessel. - Fuses for power line. - Fuses for auxiliary circuit.
- Starting relay. - Circuit breaker.
Pump operation cascade mode controlled by an electronic board type
- Electronic board type MPS 3000 with microprocessor.
MPS 3000 with microprocessor which allows different operation modes. - Terminals for pressure trasducer / level probes.
Dry-running protection with float switch or level control probes. - Connection terminals for thermal protector.
- Connection terminals for the RA 100 - RA 100A type.
- Terminals for pressure switch connection.
Technical data - Terminals for float switch or float switch connection against dry-running.
- Mains single-phase 230V ±10% 50/60 Hz (other voltages on request). - Terminals for remote signals
- Ambient temperature from -5 °C to +40 °C. - Cable glands.
- Protection IP 55.
ON REQUEST:
- Volt free contact control panel Q-MSP 13M.
- RA 100 - RA 100A control panel for remote alarm.
QTL/A 3 D Control panel for 3 pumps with three-phase motor, direct starting
614
Control panels
QTL/A 3 ST FT Control panel for 3 pumps with three-phase motor, Y/Δ starting
Construction Components
Control panel for 3 pumps with three-phase motor, Y/Δ starting, for - Metal case. - Door lock master switch. - Fuses for power line.
pressure booster sets, with working time-measuring system that stops the - Fuses for auxiliary circuit. - Starting contactors.
pump in case of lack of air cushion in the pressure vessel. - Thermal relay. - Y/Δ timers. - Transformer.
- Electronic board type MPS 3000 with microprocessor.
Pump operation cascade mode controlled by an electronic board type
- Terminals for pressure trasducer / level probes.
MPS 3000 with microprocessor which allows different operation modes: - Connection terminals for thermal protector.
standard, emergency and timed. - Connection terminals for the RA 100 - RA 100A type.
Dry-running protection with float switch or level control probes. - Terminals for pumps connection.
- Terminals for pressure switch connection.
- Terminals for float switch or flow switch connection against dry-running.
- Terminals for remote signals - Cable glands.
Technical data
- Mains 400V ±10% 50/60 Hz (other voltages on request). ON REQUEST:
- Volt free contact control panel Q-MSP 13M.
- Ambient temperature from -5 °C to +40 °C.
- RA 100 - RA 100A control panel for remote alarm.
- Protection IP 55. - Voltmeter. - Ammeter.
QTL/A 3 ST FT-RH Electric control panel for 3 drainage pumps with three-phase motor, Y/Δ starting
Construction Components
Control panel with protection for 3 submersible drainage pumps with three- - Metal case.
phase motor, Y/∆ starting. - Line selector switch with door-locking device.
Operation managed by the MPS 3000 electronic circuit board that - Power line fuses. - Auxiliary circuit fuses.
incorporates the following functions: - Contactors. - Y/∆ timers.
- changes pumps at every pump start. - Electronic board type MPS 3000 with microprocessor.
- changes working pumps after 30 minutes of uninterrupted operation. - Terminals for pressure trasducer / level probes.
- automatic functioning test of each individual pump every set hours of - Connection terminals for thermal protector.
inactivity (with pumps in the automatic functioning mode). - Connection terminals for the RA 100 - RA 100A type.
- Pump control with signals coming from: - Connection terminals for float switches.
- 4 float switches: for starting-up and stopping pump, for the alarm - Connection terminals for water seepages probe.
(maximum level is optional). - Cable glands.
- 5 float switches: for starting-up pump, for stopping the pumps and for
the alarm (maximum level is optional). ON REQUEST:
- Volt free contact control panel Q-MSP 13M.
Technical data - RA 100 - RA 100A control panel for remote alarm .
- Mains 400V 3 ~ ±10% 50/60 Hz (other voltages on request). - Voltmeter. - Ammeter.
- Ambient temperature from -5 °C to +40 °C. - Protection IP 55.
615
Control panels
QML 1 VFT Control panel for 1 pump with variable speed three-phase motor.
Construction Components
Single-phase mains supply control panel with frequency converter for 1 - Metal case. - Door lock master switch.
pump with three-phase 230V variable speed motor, for constant pressure - Fuses for power line. - Fuses for auxiliary circuit.
booster sets. - EMC filter. - Frequency converter. - MPS 4000 electronic card.
Arranged for SRL 3 level control application for probes connection against - Interface for MPS 4000 electronic board.
dry-running. - Ventilator for electric panel cooling.
Pump operation controlled by an electronic board type MPS 4000 with - Terminals board. - Terminals for remote signals
microprocessor. - Pressure transducer - Cable glands.
QTL 1 VFT Control panel for 1 pump with variable speed three-phase motor
Construction Components
Single-phase mains supply control panel with frequency converter for 2 - Metal case. - Door lock master switch.
pumps with three-phase 230V variable speed motor, for constant - Fuses for power line. - Fuses for auxiliary circuit. - EMC filter.
pressure booster sets. - Frequency converter (1 for each pump).
Arranged for SRL 3 level control application for probes connection against - MPS 4000 electronic board.
dry-running. - Interface for MPS 4000 electronic board.
Pump operation controlled by an electronic board type MPS 4000 with - Ventilator for electric panel cooling.
microprocessor alternating the starting order at each start. - Terminals board. - Terminals for remote signals
- Pressure transducer - Cable glands.
QTL 2 VFT Control panel for 2 pumps with variable speed three-phase motor
Construction Components
Control panel with frequency converter for 2 pump with three-phase - Metal case. - Door lock master switch.
variable speed motor, for constant pressure booster sets. - Fuses for power line. - Fuses for auxiliary circuit.
Arranged for SRL 3 level control application for probes connection against - EMC filter. - Frequency converter.
dry-running. - MPS 4000 electronic board.
Pump operation controlled by an electronic board type MPS 4000 with - Interface for MPS 4000 electronic board.
microprocessor. - Ventilator for electric panel cooling. - Pressure transducer
- Terminals board. - Terminals for remote signals - Cable glands.
617
Control panels
QML 1.1 VFT Control panel for 1 variable speed pump and 1 fixed speed pump
Construction Components
Single-phase mains supply control panel with frequency converter for 2 - Metal case. - Door lock master switch.
pumps, one with three-phase 230V variable speed motor and one with - Fuses for power line. - Fuses for auxiliary circuit.
fixed speed single-phase motor, for constant pressure booster sets. - EMC filter. - Frequency converter.
Arranged for SRL 3 level control application for probes connection against - Starting contactors of the second pump. - Transformer.
dry-running. - MPS 4000 electronic board.
Pump operation controlled by an electronic board type MPS 4000 with - Interface for MPS 4000 electronic board.
microprocessor. - Ventilator for electric panel cooling. - Pressure transducer
- Terminals board. - Terminals for remote signals - Cable glands.
QTL 1.1 VFT Control panel for 1 variable speed pump and 1 fixed speed pump
Construction Components
Control panel with frequency converter for 2 pumps with three-phase - Metal case. - Door lock master switch. - Fuses for power line.
motor, one with variable speed and one with fixed speed motor, for - Fuses for auxiliary circuit. - EMC filter. - Frequency converter.
constant pressure booster sets. - Starting contactors of the second pump. - Timer (Y/Δ) from 7,5 kW.
Arranged for SRL 3 level control application for probes connection against - Transformer. - MPS 4000 electronic card.
dry-running. - Interface for MPS 4000 electronic board.
Pump operation controlled by an electronic board type MPS 4000 with - Ventilator for electric panel cooling. - Pressure transducer
microprocessor. - Terminals board. - Terminals for remote signals - Cable glands.
618
Control panels
QML 3 VFT Control panel for 3 variable speeds pump with three-phase motor
Construction Components
Single-phase mains supply control panel with frequency converter for 3 - Metal case. - Door lock master switch.
pumps with three-phase 230V variable speed motor, for constant - Fuses for power line. - Fuses for auxiliary circuit.
pressure booster sets. - EMC filter. - Frequency converter (1 for each pump).
Arranged for SRL 3 level control application for probes connection against - MPS 4000 electronic card.
dry-running. - Interface for MPS 4000 electronic board.
Pump operation controlled by an electronic board type MPS 4000 with - Ventilator for electric panel cooling.
microprocessor alternating the starting order at each start. - Terminals board. - Terminals for remote signals
- Pressure transducer - Cable glands.
QTL 3 VFT Control panel for 3 pumps with variable speed three-phase motor
Construction Components
Control panel with frequency converter for 3 pumps with variable speed - Metal case. - Door lock master switch.
three-phase motor, for constant pressure booster sets. - Fuses for power line. - Fuses for auxiliary circuit.
Arranged for SRL 3 level control application for probes connection against - EMC filter. - Frequency converter (1 for each pump).
dry-running. - MPS 4000 electronic card.
Pump operation controlled by an electronic board type MPS 4000 with - Interface for MPS 4000 electronic board.
microprocessor alternating the starting order at each start. - Ventilator for electric panel cooling. - Pressure transducer
- Terminals board. - Terminals for remote signals - Cable glands.
619
Control panels
QTL 1.2 VFT Control panel for 1 variable speed pump and 2 fixed speed pumps
Code Type Motor Max current output Dimensions
400V - 3~ (Variable) (Fixed)
kW max A max A HxBxP mm
14059440000 QTL 1.2 VFT 0,45 - D 0,45 0,37 - 0,45 1,5 1 - 1,6 600x400x200
14059450000 QTL 1.2 VFT 0,75 - D 0,75 0,55 - 0,75 2,3 1,6 - 2,5 600x400x200
14047640000 QTL 1.2 VFT 1,5 - D 1,5 1,1 - 1,5 4,1 2,5 - 4 600x400x200
14048510000 QTL 1.2 VFT 2,2 - D 2,2 2,2 5,5 4 - 6,5 600x400x200
14059460000 QTL 1.2 VFT 4 - D 3 3 9,5 4 - 6,5 600x400x200
14048260000 QTL 1.2 VFT 4 - D 4 4 9,5 6,3 - 10 600x400x200
14047200000 QTL 1.2 VFT 5,5 - D 5,5 5,5 14,3 9 - 14 700x500x200
14051640000 QTL 1.2 VFT 7,5 - ST 7,5 7,5 17 11 - 17 800x600x250
14047300000 QTL 1.2 VFT 11 - ST 11 9,2 - 11 27,7 16 - 24 800x600x250
14059470000 QTL 1.2 VFT 15 - ST 15 15 33 22 - 31 800x600x250
14059480000 QTL 1.2 VFT 18,5 - ST18,5 18,5 46,3 30 - 39 1200x800x250
14048660000 QTL 1.2 VFT 22 - ST 22 22 61,5 35 - 43 1000x800x250
14059490000 QTL 1.2 VFT 30 - ST 30B 30 74,5 42 - 55 1000x800x250
14059500000 QTL 1.2 VFT 30 - ST 30A 30 74,5 55 - 65 1000x800x250
14059510000 QTL 1.2 VFT 37 - ST 37 37 88 61 - 84 1200x800x300
14059520000 QTL 1.2 VFT 45 - ST 45 45 106 80 - 105
14059530000 QTL 1.2 VFT 55 - ST 55 55 145 100 - 125
14059540000 QTL 1.2 VFT 75 - ST 75 75 173 120 - 160
Construction Components
Control panel with frequency converter for 3 pumps with three-phase - Metal case. - Door lock master switch. - Fuses for power line.
motor: one with variable speed motor (with frequency converter) and 2 - Fuses for auxiliary circuit. - EMC filter. - Frequency converter.
with fixed speed motor, for constant pressure booster sets. - Starting contactors of the second and third pump.
Arranged for SRL 3 level control application for probes connection against - Timer (Y/Δ) from 7,5 kW. - Transformer.
dry-running. - MPS 4000 electronic board.
Pump operation controlled by an electronic board type MPS 4000 with - Interface for MPS 4000 electronic board.
microprocessor alternating the starting order at each start. - Ventilator for electric panel cooling. - Pressure transducer
- Terminals board. - Terminals for remote signals - Cable glands.
QTL 4 VFT Control panel for 4 pumps with variable speed three-phase motor
Construction Components
Control panel with frequency converter for 4 pumps with variable speed - Metal case. - Door lock master switch.
three-phase motor, for constant pressure booster sets. - Fuses for power line. - Fuses for auxiliary circuit.
Arranged for SRL 3 level control application for probes connection against - EMC filter. - Frequency converter (1 for each pump).
dry-running. - MPS 4000 electronic board.
Pump operation controlled by an electronic board type MPS 4000 with - Interface for MPS 4000 electronic board.
microprocessor alternating the starting order at each start. - Ventilator for electric panel cooling. - Pressure transducer
- Terminals board. - Terminals for remote signals - Cable glands.
620
Control panels
QTL 1.3 VFT Control panel for 1 variable speed pump and 3 fixed speed pumps
Construction Components
Control panel with frequency converter for 4 pumps with three-phase - Metal case. - Door lock master switch. - Fuses for power line.
motor: one with variable speed motor (with frequency converter) and 3 - Fuses for auxiliary circuit. - EMC filter. - Frequency converter.
with fixed speed motor, for constant pressure booster sets. - Starting contactors of the second, third and fourth pump.
Arranged for SRL 3 level control application for probes connection against - Timer (Y/Δ) from 7,5 kW. - Transformer. - MPS 4000 electronic board.
dry-running. - Interface for MPS 4000 electronic board.
Pump operation controlled by an electronic board type MPS 4000 with - Ventilator for electric panel cooling. - Pressure transducer
microprocessor alternating the starting order at each start. - Terminals board. - Terminals for remote signals - Cable glands.
Construction Components
RA 100 Control panel for remote alarm. - Thermoplastic case.
RA 100A Self powered control panel for remote - Transformer card with terminals.
alarm. - Buttons card with led.
- Flashing light.
Technical data - Buzzer.
- Mains single-phase 220-230 V. - Cable glands.
- Ambient temperature from -5 °C to +40 °C. - Charger (only for RA 100A).
- Protection IP 44. - Battery (only for RA 100A).
HxBxP mm
14045600000 Q-MSP 9M 160x120x75
14045960000 Q-MSP 13M 160x120x75
621
03/2021
SMAT
ELECTRONIC PROTECTION DEVICE FOR PUMP
Construction
Electronic device for pumps protection, the device stops the
pump in case of dry running and motor overcurrent.
Electrical connection
- To pump motor cable (Schuko plug built-in)
- To electric line socket (Schuko plug built-in)
Applications
For protection of the pump:
The device protect the pump: - against dry running;
- against overcurrent.
Operating conditions
Maximum ambient temperature max 55 °C.
Single-phase mains voltage: 230 V ±10%.
Frequency: 50 - 60 Hz.
Protection IP 65.
Pump motor current Minimum 3 A - Maximum 8 A.
Control Panel
made in italy
Operation
622
SMAT
ELECTRONIC PROTECTION DEVICE FOR PUMP
123
P533
made in italy
50 78
87
Example of installation
In order to operate, the electrical power supply of the pump must be connected to the mains.
For this reason the power supply plug of the pump must be inserted in the socket of the device which is in turn connected to the power point (see Figure).
In case of a water shortage on suction, the device will stop the pump and protect it against dry running.
This malfunctioning is indicated with the red "Failure" Led lit up.
In case of the current absorption exceeding 8 amperes, the device will stop the pump motor and protect it
against over-current.
This malfunctioning is indicated with the red "Failure" Led lit up.
To restore normal operation to the device and the system simply press the red "Restart" button.
In case of a blackout, it will automatically rearm again several seconds after the electricity returns.
made in italy
623
03/2021
PMAT
PRESSURE SWITCHES FOR WATER SYSTEM APPLICATIONS
Construction
- Pressure switches for use with water in autoclave systems
- The switch ensures automatically the starting and stopping of the
electric pump according to the set pressure values
- Electric contacts: normally closed and made of brass alloy with Ag-Ni
surfacing
- Terminals with M4 screws and 8x8 mm pressure dice
- NBR rubber membrane with textile insert (food grade for PMAT 5M-
10, PMAT 5M/T-16, PMAT 5.5M/T-16)
- ¼"F hydraulic connection made of galvanized steel
- Standard protection degree IP 44
- Liquid temperature up to 55 °C
- Max ambient temperature: 55°C
- Tear resistant cable clamps
Technical data
2-pins Pressure Differential Factory
Adjustment key included max range setting
min max
A bar bar bar bar
PMAT 5M-10 10 1-5 0,6 2,3 1,4 - 2,8
Maximum rated voltage 250V
10 A - 250V ~ 16 A - 500V ~
16 A - 500V ~
LINE
104
.1 4.3
34
3.5 3.53
4.9 LINE 4.9
LINE LINE
Diagram seeting
6 6 14
4 4 10
cut-in (bar)
cut-in (bar)
cut-in (bar)
3 3 8
(bar)
(bar)
(bar)
2 2 6
values:
values:
values:
massima
massima
massima
Max. Seeting
Max. Seeting
Max. Seeting
1 1 4
Taratura
Taratura
Taratura
0 0 2
0 1 2 3 4 0 1 2 3 4 2 4 6 8 10
Min. Seeting
Taratura values:(bar)
minima cut-in (bar) Min. Seeting
Taratura values:(bar)
minima cut-in (bar) Min. Seeting
Taratura values:(bar)
minima cut-in (bar)
624
03/2021
ARIAMAT
AUTOMATIC AIR FEEDER
ARIAMAT Construction
The automatic air feeder ARIAMAT controls the air cushion in the pressu-
type re vessel by replacing the air dissolved in the water at every pump start.
This device limits the number of pump starts and stops, allows a better
AR 300E
use of the water reserve and improves the overall performance of the
AR 1000E automatic pressure system.
AR 2000E
Complete with connections Operation
and 1 m polyethylene pipe ARIAMAT operation is explained in pictures 1-2-3-4.
At the end of every cycle, ARIAMAT AR 300E, AR 1000E and AR
2000E let in the vessel 300, 1000 and 2000 cm3 of air respectively.
For a good operation of ARIAMAT it is necessary to have enough suc-
tion pressure in the pipe whilst the pumps are running.
If the pumps work under positive suction head and water falls to the
suction inlet, there will not be enough suction pressure in the suction
pipe to allow a correct operation of ARIAMAT; in this case, it is neces-
sary to create an artificial loss in the suction pipe, by closing gradually
the gate valve when the pump is running until the water level in the
ARIAMAT starts dropping.
When a sufficient suction pressure to grant a safe ARIAMAT operation
Materials cannot be achieved, it is recommended to feed the vessel with a com-
Component Material pressed air system and level probes.
Upper elbow Brass
Air valve Brass Description of the supply
Feeder body Polycarbonate The ARIAMAT is normally fitted on our automatic water systems.
The supply of ARIAMAT, as a spare part to be installed by the customer,
Ball valve Rubber
includes:
Conical fittings Polyethylene n° 1 ARIAMAT assembled with upper elbow and air valve;
Pipe Polyethylene m1 Polyethylene tube with ring nut and fitting for connection to the
pump suction side.
1) When the pump is stopped, 2) When starting, the pumps creates a 3) The water level in the ARIA- 4) When stopping, there is a
ARIAMAT is full of water. suction pressure which also takes the MAT drops until the ball valve back-flow of water from
water from ARIAMAT, allowing some moves to the bottom of the ARIA- the vessel through the
more water to come from the vessel. MAT closing the hole of the pipe pump, to the ARIAMAT. Air
The water through the ARIAMAT ven- connected to the pump. ARIAMAT is pushed inside the vessel.
turi sucks air from the upper valve. is now full of water.
625
03/2021
ACCESSORIES
VALVES PRESSURE GAUGES
check valve axial connection type
VNR 1 MA 0-6
VNR 1 1/4 MA 0-6 ABS
VNR 1 1/2
VNR 2 radial connection type
example: SLA 30
Assembled level probes
30 m cable length
626
ACCESSORIES
CE 97/23 PED APPROVED PRESSURE VESSELS CE 97/23 PED APPROVED MEMBRANE VESSELS
(Air tanks) (Membrane vessels)
type
SYSTEM FOR AIR INTAKE
INTGALL M
(cable 5 m, 10 m, 20 m) Kit of level probes
with compressor
type
INTGALL A
(cable 5 m, 10 m)
627
03/2021
Technical appendix
How to select a centrifugal pump
The selection of a centrifugal pump should be made according to the actual 0 U.S. g.p.m. 50 100 150 200 250
60
characteristics and conditions of the plant.
The required data for a correct selection are the following: A Ø 200
NM 50/20 180
Flow Q
Quantity of fluid delivered by the pump in the unit of time, generally expressed 50
B Ø 188 160
in m3/h.
Hm
50
55
H ft
60 62
Total manometric head Hmt 64 65 140
It is considered as the sum between the geometric head exsisting between 40 η 66%
the fluid levels and the head loss due to frictions from the fluid passage in
65 64 120
the pipework, into the pump and relevant hydraulic accessories.
The expression is the following:
30 100
0 Q m3/h 10 20 30 40 50 60
Hmt = Hg + Δpc mt fluid column 0 l/min 200 400 600 800 1000
0 l/s 2 4 6 8 10 12 14 16
Hg = geometric head inlet (Hga) + geometric head outlet (Hgp) 12
A 15
Δpc = sum of head loss of the plant calculated from the following data: 10
8
B
10
P kW
P HP
- Diameter, length and material of the suction and delivery piping (see table 6
no. 1 page 635). 4 5
- Number and type of elbows in the piping and hydraulic accessories such as 2
foot valves, gate valves, non-return valves and strainers etc. (see table no. 2
0 0
page 635).
- Type, temperature, viscosity and density of the fluid (if different from that of 20
6
NPSH m
water)
NPSH ft
15
4
10
2
Pay attention to the manometric suction lift Hga + Δpc asp, which should be 5
Hga is the difference in height between the free surface of the water, and its value is negative if the pump is installed above the free water surface.
Δpc asp is the sum of the remaining distributed (piping) and concentrate (valves, bends, etc.) suction head loss
If the final result is negative, it is often possible to adjust flow via a gate valve on the delivery side, in order to restore correct pump operating condi-
tions, without cavitation.
For fluid temperatures higher than the average of about 20°C, the pumps loose their suction capability.
Such changes, referred to pumps with suction capability of 7 meter at normal temperature, are shown on table no. 3 page 636.
Once the flow (Q) and total manometric head of the installation (Hmt) are established, the pump absorbed power N should be calculated through
the following formula:
N = Q x H x γ in kW
367 x ηp
where:
Q = Flow in m3/h
H = Head in mt
γ = Fluid density (water = 1 kg/dm3)
ηp = Pump efficiency (Ex. Pump efficiency 68% = ➩ ηp = 0.68)
The pumps are normally connected to electric motors, which operate at 2900 rpm with 2-pole motors at 50Hz, or at 1450 rpm with 4-pole motors at 50Hz.
However, they can run at any other speed within the limits of design.
Therefore, when changing the number of revolutions, the pump performance will change according to the following rules:
The absorbed power, in proportion to the cube of the number of revolutions: N2 = N1 x ( nn21 ) 3
628
How to select a centrifugal pump
Delivery side:
70 m Ø 80 pipe pc = 5,25 m
1 Non-return valve pc = 0,5 m
1 Gate valve pc = 0,05 m Hga
3 Elbows pc = 0,09 m 4.93.180.1
629
How to select a centrifugal pump
Foot valve with strainer - Sealing member installed on the lower end of the suction pipe. It prevents the water coming out from the
piping and pump at every plant stop. It must be always immersed in the fluid at an installation depth which allows a perfect operation
without cavitation.
It is a good rule to also install a float switch to automatically stop the pump when the water goes below a fixed level.
Non-return valve - It must be installed on the pump delivery port to avoid reflux in case of a sudden stop of the plant. It is recommen-
ded using a type fitted with an inner return spring and with ogive shutter, as this will help to diminish water hammering.
Gate valve - The installation of a gate valve is very important. In addition to allowing the pump to be dissasembled without emptying
the plant, it is used to start the plant and to adjust the flow.
PIPING
The piping must be selected in-line with the water velocity which is recommended to be 1.5 meter per second on the suction side and
3 meter per second on the delivery side. The calculation of the suction piping must be carefully checked so as to avoid the maximum
head loss and allow the pumps maximum suction capability. The piping must be perfectly tight and have no counterslopes towards the
pump port, so to avoid the development or entrapment of air bubbles or pockets.
All the piping must be secured to rests, so that they will not weigh on the pump ports.
Jammed pump This may happen after periods of inactivity due to inner oxidation.
To release smaller sized monobloc electropumps use a screwdriver at the notch on the back part
of the shaft.
For the larger sizes, turn on the shaft or the flexible coupling
Pumps which do not prime Pump and/or suction pipe with air entraped.
Uncomplete priming or totally unprimed.
Possible air entering from taps, drain or fill plugs, joints or stuffing box
Foot valve not fully immersed in the fluid or obstructed by deposits.
Suction lift too high compared with the capability of the pump.
Wrong direction of rotation
Wrong number of revolutions
Insufficient flow Piping and accessories of too small a diameter which cause too high head loss.
Jammed impeller with presence of debris in the vanes.
Corroded or broken impeller
Impeller wear rings and/or pump casing worn by abrasion.
Gas presence in the water, or too high fluid viscosity in case of fluids different from water.
Noise and vibrations in the Unbalanced rotary part or worn ball bearings.
pump Pump and piping not properly secured.
Too low flow rate for the selected pump
Operation with cavitation
630
How to select a Pressure Boosting Sets
Residential buildings
The main data needed for calculation of the quantity of water required is given in the following list:
- the number of outlets
- consumption per each type of outlet (Tab.1)
- the contemporaneity factor (Fc)
The maximum theoretical requirement is given by the sum of the quantities of water delivered to the various outlets of an appartment multiplied by the
number of appartments. In practice, it is generally found that only some of the outlets are used simultaneously.
The contemporaneity factor (Fc) allows for definition of the real maximum delivery that may be required by the outlets.
The following formulae are used to calculate the Fc factor. The value “Ut” is the total number of outlets (the number of outlets in an appartment multi-
plied by the number of appartments).
1
Appartments with 2 toilets - flush-type tank: Fc =
V1,1 x Ut
1
Appartments with 2 toilets - fast-feed type: Fc =
V0,83 x Ut
Diagram A gives the values of actual delivery, which depend on the number of appartments connected to the water-supply system. Seven outlets are
hypothesized for one-bathroom appartments and ten outlets for two-bathroom appartments.
Non-residential buildings
For calculation of quantities of water required, the following types of building are considered:
- offices
- shopping centres
- hospitals
- hotels
These buldings require quantities of water greater than those needed in residential buildings.
Diagram B shows the values of actual delivery for the main types of building. The values are based on hypothetical numbers of persons present in
these buildings.
These values offer a guideline and may vary in accordance with particular requirements of projects.
631
How to select a Pressure Boosting Sets
500
A Consumption in residential buildings
400
300
200
100
- Flats number
50
40
Flats number
30
NR. Appartamenti
20
1 2 3 4
10
5
4
3
1
1 Q m3/h 2 3 4 5 6 7 8 9 10 20 30 40 50 100 150
72.850/1
1 Appartamenti con 1 bagno, wc a cassetta 1 Appartments with one toilet, flush-tank type
2 Appartamenti con 2 bagni, wc a cassetta 2 Appartments with two toilets, flush-tank type
3 Appartamenti con 1 bagno, wc a passo rapido 3 Appartments with one toilet, fast-feed type
4 Appartamenti con 2 bagni, wc a passo rapido 4 Appartments with two toilets, fast-feed type
2500
B Consumption in non-residential buildings
2000
Numero presenze - Number of persons present in building
Number of persons present in building
1000
500
400
300
200
A B C D
100
50
2 Q m3/h 3 4 5 6 7 8 9 10 20 30 40 50 100 150 200
72.850/2
A Uffici A Offices
B Centri commerciali B Shopping centres
C Strutture ospedaliere C Hospitals
D Hotels D Hotels
632
How to select a Pressure Boosting Sets
Δp Δp
Pc Pc
Pr Pr
Total H
H totale
Hg+Pr+Pc-Pi+Δp HTotal H
totale
Hg Hg Ha+Hg+Pr+Pc+Δp
Pi
Ha
When the pumps draw water from a well, the dynamic height difference (Ha), when pumps are operating, should not exceed 4 m.
A greater suction head or erroneous sizing of the suction pipe may cause improper operation of the pumps - e.g. cavitation and priming loss.
The pumps are installed with a positive suction head when they are connected to a raised tank or a pressurized primary collection tank.
The pumps therefore have an initial pressure at the suction port which can vary from 0.1 bar (suction with a collection tank) to 2-3 bar (with suction from
a pressurized primary collection tank).
When choosing a pressure-boosting system, the positive value of the initial pressure (Pi) must be considered as a value to be subtracted from the hei-
ght (Hg).
The system head loss (Pc) are given by the sum of the losses of the pipes (including the suction pipe) added to the losses due to gate valves, non-
return valves, water purifiers, counters, filters, elbows etc.
Head loss in the tubes, caused by the friction of the water against the inner surface of the pipelines, may be quantified as 0.5 m per floor in the case of
new systems and 1 m per floor in the case of old systems.
To avoid pressure levels greater than 4-5 bar arriving at outlets on the lower floors of apartment blocks and other buildings with a height greater than
30 m (about 10 floors), pressure reducers must be installed at the offtake point of the lower floors or otherwise two pressure-boosting units can be
installed: one for the lower floors and one for the upper floors.
633
How to select a Pressure Boosting Sets
Vt = 9,45 x 1 = 0,327 m3
4 x 23 1 - (50 - 2)
70
From the calculation it will result in the selection of a 300 litre membrane
vessel.
634
How to select a centrifugal pump
G Ø mm Q l/min 16 50 100 150 200 300 400 500 600 700 800 1000 1500 2000 3000 4000 5000 6000 7000 8333 10000
G 1/2 DN 15 29,9
1,6
G 3/4 DN 20 7,4 56,3
0,9 2,7
G1 DN 25 2,5 19,0 68,6
0,6 1,7 3,4
G 1 1/4 DN 32 0,7 5,7 20,6 43,6 74,4
0,3 1,0 2,1 3,1 4,1
G 1 1/2 DN 40 0,3 1,9 6,9 14,7 25,1 53,1 90,5
0,2 0,7 1,3 2,0 2,7 4,0 5,3
G2 DN 50 0,6 2,3 5,0 8,5 17,9 30,5 46,2 64,7 86,1
HL 0,4 0,8 1,3 1,7 2,5 3,4 4,2 5,1 5,9
v 0,2 0,7 1,4 2,4 5,0 8,5 12,9 18,0 24,0 30,7 46,4
G 2 1/2 DN 65
m/100m 0,3 0,5 0,8 1,0 1,5 2,0 2,5 3,0 3,5 4,0 5,0
DN 80 m/s 0,5 0,9 1,8 3,1 4,7 6,6 8,7 11,2 16,9 35,8 60,9
0,5 0,7 1,0 1,3 1,7 2,0 2,3 2,7 3,3 5,0 6,6
DN 100 0,6 1,0 1,6 2,2 2,9 3,8 5,7 12,1 20,6 43,6 74,2
0,6 0,8 1,1 1,3 1,5 1,7 2,1 3,2 4,2 6,4 8,5
DN 125 0,7 1,0 1,3 1,9 4,1 6,9 14,7 25,0 37,8 53,0 70,5
0,8 1,0 1,1 1,4 2,0 2,7 4,1 5,4 6,8 8,1 9,5
DN 150 0,5 0,8 1,7 2,9 6,0 10,3 15,6 21,8 29,0 40,1 56,2
0,8 0,9 1,4 1,9 2,8 3,8 4,7 5,7 6,6 7,9 9,4
DN 200 0,2 0,4 0,7 1,5 2,5 3,8 5,4 7,1 9,9 13,8
0,5 0,8 1,1 1,6 2,1 2,7 3,2 3,7 4,4 5,3
DN 250 0,2 0,5 0,9 1,3 1,8 2,4 3,3 4,7
0,7 1,0 1,4 1,7 2,0 2,4 2,8 3,4
DN 300 0,2 0,4 0,5 0,7 1,0 1,4 1,9
0,7 0,9 1,2 1,4 1,7 2,0 2,4
Table no. 1.1 Head loss in m for Polyethylene PE 100 - PFA 16 pipes
Pipe
Tubo Q m3/h 1 3 6 9 12 18 24 30 36 42 48 60 90 120 180 240 300 360 420 500 600
Ø est. Ø int.
Q l/min 16 50 100 150 200 300 400 500 600 700 800 1000 1500 2000 3000 4000 5000 6000 7000 8333 10000
mm mm
32 26 1,4 10,4 37,5 79,4
0,5 1,6 3,1 4,7
40 32,6 0,5 3,4 12,4 26,4 44,9
0,33 1,00 2,00 3,00 3,99
50 40,8 0,2 1,2 4,2 8,8 15,1 31,9 54,4
0,2 0,6 1,3 1,9 2,5 3,8 5,1
63 51,4 0,4 1,4 2,9 4,9 10,4 17,7 26,7 37,4 49,8 63,7
0,4 0,8 1,2 1,6 2,4 3,2 4,0 4,8 5,6 6,4
75 61,4 0,2 0,6 1,2 2,1 4,4 7,4 11,2 15,7 20,9 26,8 40,5
0,3 0,6 0,8 1,1 1,7 2,3 2,8 3,4 3,9 4,5 5,6
90 73,6 0,2 0,5 0,9 1,8 3,1 4,6 6,5 8,7 11,1 16,8 35,5 60,5
0,4 0,6 0,8 1,2 1,6 2,0 2,4 2,7 3,1 3,9 5,9 7,8
110 90 0,1 0,2 0,3 0,7 1,2 1,7 2,4 3,3 4,2 6,3 13,3 22,7 48,1
0,3 0,4 0,5 0,8 1,0 1,3 1,6 1,8 2,1 2,6 3,9 5,2 7,9
125 102,2 0,1 0,2 0,4 0,6 0,9 1,3 1,7 2,2 3,4 7,2 12,2 25,9 44,1
0,3 0,4 0,6 0,8 1,0 1,2 1,4 1,6 2,0 3,0 4,1 6,1 8,1
HL
140 114,6 v 0,1 0,1 0,2 0,4 0,5 0,8 1,0 1,3 1,9 4,1 7,0 14,8 25,3 38,2 53,5
0,2 0,3 0,5 0,6 0,8 1,0 1,1 1,3 1,6 2,4 3,2 4,8 6,5 8,1 9,7
m/100m 0,1 0,1 0,2 0,3 0,4 0,5 0,7 1,0 2,2 3,7 7,8 13,3 20,1 28,1 37,4
160 130,8 m/s 1,9 2,5 3,7 5,0 6,2 7,4 8,7
0,2 0,4 0,5 0,6 0,7 0,9 1,0 1,2
180 147,2 0,1 0,1 0,2 0,2 0,3 0,4 0,6 1,2 2,1 4,4 7,5 11,3 15,8 21,0 29,1 40,7
0,3 0,4 0,5 0,6 0,7 0,8 1,0 1,5 2,0 2,9 3,9 4,9 5,9 6,9 8,2 9,8
200 163,6 0,1 0,1 0,1 0,2 0,2 0,3 0,7 1,2 2,6 4,5 6,7 9,5 12,6 17,4 24,4
0,32 0,40 0,48 0,55 0,63 0,79 1,19 1,59 2,38 3,17 3,96 4,76 5,55 6,61 7,93
225 184 0,1 0,1 0,1 0,1 0,2 0,4 0,7 1,5 2,5 3,8 5,3 7,1 9,8 13,7
0,3 0,4 0,4 0,5 0,6 0,9 1,3 1,9 2,5 3,1 3,8 4,4 5,2 6,3
250 204,6 0,1 0,1 0,1 0,2 0,4 0,9 1,5 2,3 3,2 4,2 5,8 8,2
0,4 0,4 0,5 0,8 1,0 1,5 2,0 2,5 3,0 3,5 4,2 5,1
280 229,2 0,1 0,1 0,2 0,5 0,9 1,3 1,8 2,4 3,4 4,7
0,4 0,6 0,8 1,2 1,6 2,0 2,4 2,8 3,4 4,0
315 257,8 0,1 0,1 0,3 0,5 0,7 1,0 1,4 1,9 2,7
0,5 0,6 1,0 1,3 1,6 1,9 2,2 2,7 3,2
355 290,6 0,1 0,2 0,3 0,4 0,6 0,8 1,1 1,5
0,5 0,8 1,0 1,3 1,5 1,8 2,1 2,5
Q Flow. HL Head loss, m per 100 m. v = Flow velocity: max 1,5 m/s for suction and 3 m/s for delivery.
635
How to select a centrifugal pump
Table no. 2 Head loss in cm for bends, gate valves, foot valves and check valves
R
flow
α = 30 α = 40 α = 60 α = 80 α = 90 d
velocity
d d d d d
= 0,4 = 0,6 = 0,8 =1 = 1,5
m/sec. R R R R R
0,4 0,43 0,52 0,71 1,0 1,2 0,11 0,13 0,16 0,23 0,43 0,23 32 31
0,5 0,67 0,81 1,1 1,6 1,9 0,18 0,21 0,26 0,37 0,67 0,37 33 32
0,6 0,97 1,2 1,6 2,3 2,8 0,25 0,29 0,36 0,52 0,97 0,52 34 32
0,7 1,35 1,65 2,2 3,2 3,9 0,34 0,40 0,48 0,70 1,35 0,70 35 32
0,8 1,7 2,1 2,8 4,0 4,8 0,45 0,53 0,64 0,93 1,7 0,95 36 33
0,9 2,2 2,7 3,6 5,2 6,2 0,57 0,67 0,82 1,18 2,2 1,20 37 34
1,0 2,7 3,3 4,5 6,4 7,6 0,7 0,82 1,0 1,45 2,7 1,45 38 35
1,5 6,0 7,3 10 14 17 1,6 1,9 2,3 3,3 6 3,3 47 40
2,0 11 14 18 26 31 2,8 3,3 4,0 5,8 11 5,8 61 48
2,5 17 21 28 40 48 4,4 5,2 6,3 9,1 17 9,1 78 58
3,0 25 30 41 60 70 6,3 7,4 9 13 25 13 100 71
3,5 33 40 55 78 93 8,5 10 12 18 33 18 123 85
4,0 43 52 70 100 120 11 13 16 23 42 23 150 100
4,5 55 67 90 130 160 14 21 26 37 55 37 190 120
5,0 67 82 110 160 190 18 29 36 52 67 52 220 140
3
(mwc)
3
MANOMETRIC SUCTION LIFT
5 E
U RV
C
6 AL
(mwc)
TI C
PRAC
7
8
E
LC URV
9 E TIC A
THEOR
10
11
0 10 20 30 40 50 60 70 80 90 100 110
WATER TEMPERATURE IN DEGREES CELCIUS
Diagram referred to pumps with manometric suction head of 7 mwc. at 20 °C
636
Technical appendix
Electric pumps powered by frequency converter
The use of a frequency converter to power an electric pump, offers the possibility of operating in different working points according to
the needs of the system, and hydraulic or mechanical performance desired. However, this possibility is detrimental to the quality voltage
and consequently also to the current circulating in the motor. Figure 1 shows the current sinusoid at the output of the converter, which
has some “noise”, i.e. sinusoids with high frequency but moderate amplitude.
The stray capacitances with high frequency have a low impedance, allowing the circulation of current harmonics in the motor casing
and bearings, thus compromising their correct functioning. The most common methods to reduce this phenomenon are:
The dv/dt filters consist of inductors and capacitors with cut off frequency higher than switching frequency of the converter. Filters reduce
the voltage rise time making the current more sinusoidal. Figure 2 shows that current sinusoid contains less harmonics than the current
without dv/dt filter.
The IEC 60034-17 technical specification prescribes the rise time value (dv/dt) that the supply voltage must have according to the peak
values it assumes, so that the current can not damage the bearings (figure 3).
1000 1000
500 500
U LL [V]
U LL [V]
0 0
-500 -500
-1000 -1000
0 5 10 15 20 25 30 35 40 0 5 10 15 20 25 30 35 40
20 20
10 10
I u [A]
I u [A]
0 0
-10 -10
-20 -20
0 5 10 15 20 25 30 35 40 0 5 10 15 20 25 30 35 40
Time [ms] Time [ms]
Figure 1: Voltage and current trends without dv/dt filter Figura 2: Voltage and current trends with dv/dt filter
Figure 3: Limiting curve of admissible impulse voltage ULL at the motor terminals
as a function of the rise time tr
637
Technical appendix
EFFICIENCY OF ELECTRIC MOTORS
COMMISSION REGULATION (EU) 2019/1781
Having regard to Directive 2009/125/EC of the European Parliament establishing a framework for the setting of ecodesign requirements for energy-
related products, it specifies the time and the efficiency levels that motors sold in the European market will have to comply.
VSDs integrated:
(a) VSDs integrated into a product and whose energy performance cannot be tested independently from the product, that is to say that an attempt
to do so would render the VSD or the product inoperative;
(b) VSDs qualified specifically for the safety of nuclear installations, as defined Article 3 of Directive 2009/71/ Euratom;
(c) regenerative drives; (d) drives with sinusoidal input current.
638
Technical appendix
EFFICIENCY OF ELECTRIC MOTORS
Summary table of the levels of efficiency as expected in IEC 60034-30
Rated power
Potenza Efficienza%%
Efficiency 2-pole
2 poli
output
nominale
kW
kW IE2 IE3 IE4
0,25 64,8 69,7 74,3 100
0,3 67,1 71,6 76,1
0,33 68,2 72,6 77,1
0,37 69,5 73,8 78,1 95
0,45 71,7 75,8 79,9
0,55 74,1 77,8 81,5
0,75 77,4 80,7 83,5 90
IE4
1,1 79,6 82,7 85,2
1,5 81,3 84,2 86,5
85
1,8 82,2 85 87,3 IE3
%
Efficienza%
Rated power
Potenza Efficiency
Efficienza%% 4 poli
4-pole
output
nominale
kW
kW IE2 IE3 IE4
0,25 68,5 73,5 77,9 100
0,3 70,5 75,3 79,5
0,33 71,5 76,2 80,3
0,37 72,7 77,3 81,1 95
0,45 74,8 79 82,5
0,55 77,1 80,8 83,9
0,75 79,6 82,5 85,7 90
1,1 81,4 84,1 87,2
1,5 82,8 85,3 88,2 IE4
85
1,8 83,5 86 88,8
IE3
Efficienza %
639
Technical appendix
EFFICIENCY OF WATER PUMPS
With the Eco-design Directive of Energy Using Products (ErP Directive – Energy-related Products) the
European Union wants to improve the design of equipment that “consume” significant energy (e.g.
televisions, refrigerators, washing machines, boilers, pumps, motors etc.) to improve eco-design
providing environmental sustainability, reducing negative environmental impact as the consequence of
production, use and disposal of products.
The objective of the Directive is to force manufacturers and importers to produce and distribute products
with high energy efficiency, and reduced carbon output.
The criteria for eco-design will be an integral part of the declaration of conformity (CE), which is a
necessary requirement/mark for products being sold in the EU.
- End suction own bearing water pumps (ESOB) designed for pressures up to 16 bar, a maximum shaft power of 150 kW, a maximum head of 90 m at
nominal speed of 1450 rpm and a maximum head of 140 m at nominal speed of 2900 rpm;
- End suction close coupled water pumps (ESCC) designed for pressures up to 16 bar, a maximum shaft power of 150 kW, a maximum head of 90 m
at nominal speed of 1450 rpm and a maximum head of 140 m at nominal speed of 2900 rpm;
- End suction close coupled in-line water pumps (ESCCi) designed for pressures up to 16 bar, a maximum shaft power of 150 kW, a maximum head of
90 m at nominal speed of 1450 rpm and a maximum head of 140 m at nominal speed of 2900 rpm;
- Vertical multistage water pumps (MS-V) designed for pressures up to 25 bar, with a nominal speed of 2900 rpm and a maximum flow of 100 m3/h
(27,78·10–3 m3/s);
- Submersible multistage water pumps (MSS) with a nominal outer diameter of 4″ (10,16 cm) or 6″ (15,24 cm) designed to operate in a borehole at
nominal speed of 2 900 rpm, at operating temperatures within a range of 0 °C and 90 °C;
The MEI value of Calpeda pumps is available on the web site www.calpeda.com
Catalogue 50Hz
March 2021 C201-18/3
Changes reserved
640