Requirement in Foundation Engineering
Requirement in Foundation Engineering
3rd floor
LL = 1.9 KN/m2
Factored Load = (1.2*5.3125) + (1.6*1.9) = 9.415 KN/m 2
2nd floor
LL = 4.8 KN/m2
Factored Load = (1.2*5.3125) + (1.6*4.8) = 14.055 KN/m 2
3) Load of walls
Height of walls = 3 – 0.5 = 2.5 m
Self weight of wall = 0.1*2.5*23.54 = 5.885 KN/m
Factored load = 1.4*5.885 = 8.239 KN/m
4) Load of beam
Self weight of beam = 0.5*0.3*23.54 = 3.531 KN/m
Factored load = 1.4*3.531= 4.9434 KN/m
Load on column
1) Roof to 3rd floor
Roof load = 7.895*5*3.5 = 138.1625 KN
Beam load = 4.9434* 8.5 = 42.0189 KN
Walls load = 8.239* 8.5 = 70.0315 KN
Total = 250.2129 KN
Total = 527.0258 KN
3) 2nd to plinth
Floor load = 14.055*5*3.5 = 245.9625 KN
Beam load = 4.9434* 8.5 = 42.0189 KN
Walls load = 8.239* 8.5 = 70.0315 KN
Loads from top floor = 527.0258 KN
Total = 885.0387 KN
Total = 970.74784 KN