Footing With Moment

- The document provides design calculations for an isolated reinforced concrete footing with biaxial bending moments. - The footing has dimensions of 1.67m length, 1.59m width, and 0.5m depth with 10mm diameter reinforcement bars spaced at 125mm. - Calculations are shown for checking gross bearing pressure, determining design forces, calculating bottom steel reinforcement, and checking one-way shear stress. - The footing design is for a column with 230mm width, 300mm depth, applying 725kN axial load and 5kNm moments in both the x and z axes.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as XLS, PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
178 views4 pages

Footing With Moment

- The document provides design calculations for an isolated reinforced concrete footing with biaxial bending moments. - The footing has dimensions of 1.67m length, 1.59m width, and 0.5m depth with 10mm diameter reinforcement bars spaced at 125mm. - Calculations are shown for checking gross bearing pressure, determining design forces, calculating bottom steel reinforcement, and checking one-way shear stress. - The footing design is for a column with 230mm width, 300mm depth, applying 725kN axial load and 5kNm moments in both the x and z axes.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as XLS, PDF, TXT or read online on Scribd
You are on page 1/ 4

ISOLATED FOOTING WITH BIAXIAL MOMENT

DESIGN OF BI-AXIAL ISOLATED RCC FOOTING (IS 456, 2000)


Building Name
Footing Number:
Node number
COLUMN
WIDTH (Breadth) = 230 mm
DEPTH (Length) = 300 mm
Axial load from output (P1) = 725 KN
Moment about Z axis (Mz) = 5 KN-m
Moment about X axis (Mx) = 5 KN-m
Safe bearing pressure = 300 KN/m2
AREA= 2.658333333 mm2

1 x2 -0.07 x -2.65833333
Required length of the footing L 1.665815
Required width of the footing w -1.595815
Depth required 171.0741781
Over All Depth 226.0741781

PEDASTAL Z and X axis are assumed as two horizontal Glob


Hence, input the dimensions of footing easily by
Breath = 230 mm length parallel to global Z and footing breadth p
Length = 300 mm global
X
Breadth 1.59 m
FOOTING
Revised Footing length (L, dim. ) = 1.67 m global
Revised Footing Breadth (W, ) = 1.59 m global
Z Z
Depth of footing (t) = 500 mm
Clear cover of footing = 50 mm global
Main bar dia of footing = 10 mm X
Effective depth of footing = 445 mm Length 1.67 m
Selfweight of the footing = 33.19 KN
Footing Dimensions
Area of Footing(A) = 2.66 m2
Sect mod of foot about Z axis (Zz) = 0.70 m3
Sec mod of foot about X axis (Zx) = 0.74 m3

MATERIALS OF CONSTRUCTION
Grade of concrete fck = 25 N/mm2
Grade of steel fy = 500 N/mm2
Unit wt of soil = 18 KN/m3
CHECK FOR GROSS BEARING PRESSURE
Safe NET bearing pressure = 300 KN/m2
Safe gross bearing pr. = 327.00 KN/m3 (net pr. + depth of foot * soil unit wt)
Axial load from output (P1) = 725 KN
Moment about Z axis (Mz) = 5 KN-m
Moment about X axis (Mx) = 5 KN-m
Depth of top of foot. from ground = 1 m
Unit wt of soil = 18 KN/m3
Weight of soil retained above foot = 46.55 KN
P = (P1+soil+foot self wt) = 804.74 KN
Maximum bearing pressure = 316.94 KN/m2 P M y Mx
± ±
Minimum bearing pressure = 289.20 KN/m2 A Zy Zx
Hence footing is safe against max gross bearing pr.

DESIGN FORCES self wt of footing & soil wt


Axial load:(Pu) = is not considered in Pu.
1087.5 KN
Moment about Z axis (Muz) = 7.5 KN-m
Moment about X axis (Mux) = 7.5 KN-m
Maximum effective soil pressure pe max
( Pu/Area+ Muz/Zz + Mux/Zx) = 430.36 KN/m2
Minimum effective soil pressure pe min
( Pu/Area - Muz/Zz - Mux/Zx) = 388.75 KN/m2
Design of footing is done using above maximum effective soil pressure

Page 1
ISOLATED FOOTING WITH BIAXIAL MOMENT

CALCULATION FOR BOTTOM STEEL


Mu about X1 X1 = ( pe max x length2/2)= 100.97 KN-m per meter If this moment is very high try to
reduce moment by changing
Mulimit = 658.56 KN-m per meter
footing size.
A st =
0. 5 f ck
fy [ √
1− 1−
4.6 Mu
f ck bd 2
bd
] The section is singly reinforced Higher moment will require
higher steel and section may be
doubly reinforced. This design is
done as singly reinforced
Hence, Ast = 534.712 mm2 section.
Min Ast = 534.000 mm2 (0.12 % for slab, cl 26.5.2.1)
Spacing required = 146.88 mm (considering max of above two calculated values of Ast)
Spacing provided = 125 mm
pt provided = 0.14 %
pt required = 0.12 %
provide a maximum st 0.14 %
Hence provide 10 mm dia bar @ 125 mm c/c parellel to length of footing ( || to Z)

Mu about N1 N1 = ( pe max x length2/2)= 99.50 KN-m per meter


Calc. Ast = 526.742 mm2 The section is singly reinforced
Min Ast = 534 mm2 (0.12 % for slab, cl 26.5.2.1)
Spacing = 147.08 mm (considering max of above two calculated values of Ast)
Spacing provided = 125 mm
pt provided = 0.14 %
pt required = 0.12 %
provide a maximum st 0.14 %
Hence provide 10 mm dia bar @ 125 mm c/c parellel to breadth of footing ( || to X)
Arrangement of bottom reinforcement as per above design is shown below

10 mm dia bar @ 125 mm c/c All drawings on this sheet


are updated automatically
as per design changes and
need not be edited.

10 mm dia bar @ 125 mm c/c

1 1

Footing Length 1670 mm Breadth 1590 mm

Sec 1-1

300 230
675
L1 X1 X

a a

Z Z
N1 N1
a a

L2 L2

240 X1 X
L1 Breadth 1590 mm
745
Footing Length 1670 mm 235
PLAN

Page 2
ISOLATED FOOTING WITH BIAXIAL MOMENT

CHECK FOR ONE WAY SHEAR :


One way shear at critical section L1- L1
Distance of critical sec. from edge of footing = 0.24 m
Shear force Vs =pe max x 0.24 x 1m width of footing = 103.288 KN
Instead of calculating
tv = Vs/bd = accurate pressure
Shear stress 0.232 N/mm2 ordinate at L1-L1 we
tc = 0.28 N/mm2 have used "pemax" on
conservative side.
tv < tc hence O.K.

One way shear at critical section L2- L2


Distance of critical sec. from edge of footing = 0.235 m
Shear force Vs =pe max x 0.235 x 1m width of footing = 101.136 KN
Shear stress tv = Vs/bd = 0.227 N/mm2
tc = 0.28 N/mm2
tv < tc hence O.K.

CHECK FOR TWO WAY SHEAR


Ref. cl 34.2.4 and cl.31.6.3 of IS 456 : 2000
Allowable shear stress tv allowable = kstc
ks = ( 0.5 + bc) = 1.266666667 >1
Hence, ks= 1
tc = 0.25 (fck)0.5 = 1.25 N/mm2
tv allowable = ks x tc = 1.25 N/mm2
Shear force Vs = 430.364 ( 1.67 x 1.59 - 0.745 x 0.675) = 926.33 KN
Length of critical section = 2 x ( 745 + 675) = 2840 mm
Area of the critical section (length of critical sec x eff. d ) = 1263800 mm2
Hence shear stress tv = 0.733 N/mm2
tv < allowable hence O.K.