0% found this document useful (0 votes)
54 views12 pages

MT Series

FOTEK Temp Control

Uploaded by

Rizqi Firmansyah
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF or read online on Scribd
0% found this document useful (0 votes)
54 views12 pages

MT Series

FOTEK Temp Control

Uploaded by

Rizqi Firmansyah
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF or read online on Scribd
You are on page 1/ 12
Mii ye Ss & Sa HCN BIAS VALUE SETTABLE FeOMMIANCe MT Series PID+Fuzzy Temperature Controller , | FUZZY PID CONTROLLER ¥Actificial IntelligenceControl FUZZY+PID CONTROL are Enhanced Autotunning Mi AT BIAS VALUE SETTABLE 2¥Muti-Input Type K/J/PT SELECTABLE | 3Alarm Function 15 MODES SELECTABLE 3RUN/STOP Function ommunication Function OPERATED ONTHE PANELEASILY —RS-485 OPTIONED MB Guiding of Model /#138%5| EX. MT-4896-R-RS-mA ®@Others/# tt © ®@O@® Non=Standard @ Series/% Hilt RS=RS-485 MT Series Temperature Controller CT=Current Transmitter S:PV Resender @ Outline/y. 9 Rt 4896=48x96 mmxmm © Input/ti A 48=48x48 mmxmm Non=K/J/PT ° - mA=mA 72=72x72 mmxmm veoioy 96=96x96mmxmm VR=Variable Resisfance ®@ 20=48(W)x96(H) mmm. 21=96(W)x48(H) mmxmm @ Output Method/#a Hi xt R=Relay Output V=Voltage Pulse Output L=Linear 4~20 mA Output @Nomenclature/|al a PV:Display of The Process Value BR 38 7 if SV:Display of The Setting Value BA 7 £5 2 i@ fe):Key of Setting a2 88 Key of Shift & Function 5p a 8 #3 0 88 Key of Increasing Autotunning + pn if & 6 i812 ie me ed ‘Key of Decreasing & ON/OFF F itt 8 22 BA RAG MT ° PID+Fuzzy Temperature Controller series General Specification/ 4 |i] #3 : 90~265 VAC 50/60Hz Power Supply If SE | Power Consumption 34 #€ 2) 5VA Max. ic Sensor Input jl i #8 K/J/PT-100Q Selectable | Relay #73 SPDT IC 5A/250 VAC | Control Output | poe ea Voltage BE 12V/50mA 4~20mA, Load:6009 Max SPST 1/a 5A/250 VAC Alarm Output 3 3886 4 Control Method #éi 7st FUZZY+PID or ON/OFF Settable -10°C~+75°C @ Ambient Temperature L ft #2 1% ia & Ambient Humidity 1 (Rta RE 25%~85% RH Linear ‘(Ht @ Characteristic/#¥ tt k +(0.1% of F.S. + 1 Digit) — CycleTime SiH 0~99 sec Proportional Band(P) & (la 0~999 Integral Time MOAR 0~3999 sec | 6 Derivative Time (D) #3 86 fi) 0~3999 sec Alarm Range #8 @ Hh) -99~-999 PV Sampling Time BA 7 (i Hy #265 Pa 0.1sec Input Shift(Bias) # A# IE -99~+99 AT Bias (TU) 3 2 0-999 Memory Method #218 st EEPROM Insulation Resistance # #0 ii Over 50M2/500VDC Dielectric Strength fi} 34 A Over 2.5KV/1minute EMC Standard ESD:8KV Air Discharge(Level 8EN-61000-4-2| e RF Interference: 10V/M/ENV50140 BURST TEST:2KV/EN61000-4-4 MT eries Mode Setting 2K Symbols SRA i Control Status 19395 HERE > T333) PES: IEE [Cycle Time [te] Eafe A oa wale Yes belio Auto Tunnin! | > (=e (6pm 6 ela Autotunning Bias » 5] mee [Proportional Band »C# ek Bl) Les} ee) [integral Time _SEC , T AD Bs A) 150 is a Derivative Time SEC [a] PS BAA | a} 0 re Hysteresis cre, [55] BARE Le zoe rv Input Selecting fimmsi22 RARE a wee ye Gey Unit Selecting ‘MfLwie Decimal Poi # 7 BL —* Ls aa , Code +] [estan mee pe 2 5B IR g nee [input Shift > CRE HARE Ce (ag La las tee | ‘ontoller No. | > 04] [se fla a [20] aoa 7 Range Hl -99~1999 Oort 0~999 0~999 0~3999 0~3999 -99~999 Ki/Pt cre ort ort Appeared Only -99~999 PID+Fuzzy Temperature Controller W Setting of Parameter/B & BE Remarks fii RE @¢ ON/OFFiz fi CT=0 ON/OFF Control O aitwbe ama Linear Type Disappeared @aAt-0 wie AT=0. Control Status AT=1 6185 RE AT=1 Autotunning Status @ we fa=Sv-Tu Autotunning Value=SV-Tu @ ci-0 Perma =0 P Disappeared aL mB @ ctT=0 =0 | Disappeared onmR Ddisappeared 8 SMR peared only @ K:0~1372°C ) 012000 PT:-200~850°C 2 ® No Decimal Point One Decimal Point @O0:HEX Code 1:ASCIl Code QwRs-4053 wR Communicafion Type Appeared Only @ seems Preter to the mode of Alarm @ MRS-4057 Max Communication Type Appeared Only MT @ _PID+Fuzzy Temperature Controller series m Setting of Alarm/2 #8 #5 Remarks Limit Setting Symbols Range & euGR 2H fi a . ra -be1550 | aelaw J ron | Lock Setting ie a | Wee 8 ALi Alarm Setting (Areas | — Serene . | mae es fa) 2 = e@ AL2 Alarm Setting [AZ] 99-9999 e=SVBAL Settable AL2B Hie Tse BEM fi hi a) 3 =All lock Range Setting [HH 29-2099 @ Mode of Alarm/®& # Mish [AE] Modeii ___ Descriptioni=8 a OverHeatAlarm | a8 | V#AL1) AL’ On{Deviation) 1 Over Heat Alarrn TI i@ #835 #211 V#AL1) AL1 On(Deviation) e Under Heat Alarm [ ee i '=(SV-AL1)AL1 On(Deviation) yi Under Heat Alarm Ir (i830 11 V-AL1)AL1 On(Deviation) y Interval Alarm | RS 4 1 ~ (SV-AL1) (BOT 1G a Fs SVE) Instruction: 40H 16H 57H 46H 01H 50H ODH (8) @ ~=No.t6 «Wo Addr.t6 Data cR Response:40H 16H 57H OOH HEX ODH (ae) @ No.16 w Respenes FCS cR Ex.To Read The Output Status of No-9 (ARBTAORE 1B HB SS 9H Hh HR BEOUUALT/AI2) Instruction: 40H 09H 52H 23H ODH (33) @~=—«No® RR Addr.23. CR Response: 40H 09H 52H OOH OOH O7H HEX ODH (B®) @ No9 R Response Data FCS OR Code Data out | alt | al Data out | alt | Al 00H 00H x xX | XxX OOH 04H x x fo} OOH 01H on ee x OOH 05H ° x ° 00H 02H pete IF 9g A] Phe OOH OSH x ° ° 00H 03H ° oma OOH 07H ° ° ° "X":OFF "O":ON 3 Mt. PiO0+Fuzzy Temperature Controller ‘ willustration/ 5) fe RW ‘ime of Heater ON 0 #4 89 Fi Toff=Time of Heater OFF 7B jm #85 fi Ley {raf Autotunning Value~SV-TU Input >i tH Be TE To Correct The Difference Between The Actual Value And The PV Value BY 4 TE OR fie 0 BA ay fi 89 BR PV Resender 98 7 (i FB #2 The Range of Transmitter Is Set By The SLH. Ex. SLH=200,0~ 200 Will be Transmitted To 4~20mA "Key Fil FAS ‘To Turn OFF All Output Of Temperature Controller,Only Display The Value of PV. TRB AM AAT me ie: Atuo Tunning Key 8 &) 3 9 #2 If Press The (4) Key 3 Seconds, It May Enter To The Status of Auto Tanning. sR (A) MID + TLL A BR ' PID+Fuzzy Temperature Controller ste Outline & Fixed Hole/# 3 & az 7LAR Tal Notice ———_———$———_— mNotice of Use /i HT R48 Please Install The Temperature Controller In The Circumstance ‘Temperature:-20°C ~+75°C (Without Ieing or Condensation) Humidity:35%~85%RH The high Ambient Temperature May Shorten The Service Life of Temperature Controller,Please Don't Let It Exceed 75°C BSH eR SBE: -20°C ~+75°C (RR 48 7k BE A BE) SRE: 35%~85%RH iB RAR 7] AE ARE i IS He TAN TL fe 09 A te OE 8B BIST 2.The Service Life of Relays Are Affected By The Switching Load e Please Assure The Switching Load Are Under The Rated Current BERRGRIPAMH SRA DBE A 3.Thermcouple Type,If Need To Extend The Thermcouple Lead Wire Please Be Sure To Use The Compensation Wires That Must To Match The Thermcouple Type PT Resistance Type,If Need To Extend The PT Sensor Lead Wire Please Be Sure To Use The Low Resistance Wire. HEGRE MRALRB SDE AMR ASERVERR WRAL HDEARRLRER 4.The Lead Wire of Temperature Sensor,Please Separate It Away From The Power Lines or High Tension Lines To Avoid Noise Interruption @ SRR DMS BRB RBM EHO 5 It is Suggested To Settle The Seperated Alarm System.In Case of The Alarm of Temperature Controller May Not Be Operated Properly When The Device is Abnormal RAD ERUHERAM : URRERRPRERRMREAR 6.The Temperature Controller May Be Interrupted By Movable Phone or Wirless Device. RBS LTH SRR RBH TR t 7.Outline of Crimp Terminal 8% $ 38 54 BL CS ee Notice $$$ $ $$ Notice Of Balcly7 BAT RO Definition of Symbol! Potentially Hazardous Situation In Case Of Mishanding,May Result In Death Or Serious Injury Bee MRR RR BTR MCLE RS « Potentially Hazardous Situation In Case of Mishanding, May Result In Slight Dangerous. BE EIR MRR ATER REAR E - | 1Please Do Not Touch The Terminals While The Power Is Supplied, If Do,lt May Result In | Electronic Shock: | sR a DRAMA AR OR LL AS 2.Please Do Not Let The Metal or Wire Cuttings Drop Into The Insid of Temperature Controller, | 1fDo,]t May Resule In Malfunction, Burnning Out or Fire | HO RRB RRMA BRR BA URS RIRBAM : AMEE BK - 3 Please Make Sure To Wire The Temperature Controller Correctly Before Power ON,IfNot, | It May Result In Malfunction or Burnning out REMABRABAD ER TAA eS MAS wee 4 Please Do Not Modify or Repair The Temperature Controller, To Avoid Resulting In ® Malfunction or Burnning out. AONE CTR EE RIT UREA RISE Z\ CAUTION 1 Please Rate The Power Supply Voltage Wirhin The Specified Range,If Not,It May Result In Malfunction or Burnning. | Tf RES AUER AGS «GBT AE AA A IRI as BH | 2Please Rate The Load Within The Specified Value, If Not,It May Result In Malfunction or Burnning. TH RRM DOME TA SAA aM MI sR Ra 3.Please Settle a Seperated Alarm Syatem To Ensure Safety Protection In The Event of | Malfunction,If Not,[t May Result In A Serious Accident, Qo FRSU SFR: HERE ARHSSER SUTRA BEASM - BARBER DERAD FOTEK CONTROLS CO., LTD. Rae aie ad ilies pase pas Py

You might also like