0% found this document useful (0 votes)
27 views1 page

Iranian Petroleum Standards: (At Bathrooms & Kitchen)

Download as pdf or txt
Download as pdf or txt
Download as pdf or txt
You are on page 1/ 1

NOTE:

IN OUT IN
OUT
SECOMASTIC SECOMASTIC 1- ALL DIMENSIONS ARE IN MILLIMETERS
CONCRETE SILL(1:2:4) 40mm. THK. MARMARITE SILL UNLESS OTHERWISE STATED.
C.S.S. CAST IN SITU OR TERRAZZO SILL C.I.S. 40mm. THK. TRAV.
SEE DETAIL (1)
2- THIS DRWG. HAS TO BE READ IN

20
20

CONJUNCTION WITH IPS-M-CE-105

40
80
60

50 BRICK OR HOLLOW BLOCK


WALL SET ON 1:3 C.S.
TRAV. PANEL
50 WALL FINISHING AS/FINISH MORTAR AS/ARCH. DRWG.
SET ON 1:3
SCHEDULE C.S. MORTAR
FIRST CLASS GLAZED
WALL TILE AS/FINISH
ELEVATION AS/ARCH. BRICK OR HOLLOW BLOCK SCHED.
DRAWING WALL SET ON 1:3 C.S. MORTAR

AS/ARCH. DRWG.
AS/ARCH. DRWG.
FIRST CLASS GLAZED
WALL TILE AS/FINISH
TRAVERTINE WINDOW SILLS
CONC.& MAR. WINDOW SILLS SCHED. (AT BATHROOMS & KITCHEN)
10

1:3 C.S. MORTAR

BRICK WALL ON 1:3 C.S.


LEGEND:
OUT IN MORTAR AS/ARCH. DRWG.
DETAIL 1
MAR. SILL C.S.G. = CEMENT, SAND, GRAVEL MIX
OUT IN
CONC. = CONCRETE
40

50 SECOMASTIC
30

40mm. THK. TRAV.


50
SILL SET ON 1:3
40mm. THK. MARMARITE
C.S. = CEMENT, SAND MIX
PLASTER AS/FINISH C.S. MORTAR
DAGHOON STONE SILL SET ON 1:3 C.S.
SCHED.
FACING 1:3 MORTAR OR TERRAZZO THK. = THICK

40 20
C.S. POINTED TILE SILL

40
BRICK WALL SET ON
1:3 C.S. MORTAR 50 SCHED. = SCHEDULE
WALL FINISHING AS/FINISH
50
SCHEDULE ARCH. = ARCHITECTURAL
AS/ARCH. DRWG. BRICK WILL SET ON 1:3 C.S.
DAGHOON STONE
OR BRICK FACING MORTAR TRAV. = TRAVERTINE
1:3 C.S. POINTED
MAR. & DAGHOON STONE SILLS DRWG. = DRAWING
AS/ARCH. DRWG.

TRAV. & MAR. WINDOW SILLS C.I.S. = CAST IN SITU


IN (WITH DAGOON STONE FACING)
OUT
MAR. = MARMARITE
SECOMASTIC
OUT IN
40mm. THK. TRAV. MARMARITE SILL C
SILL SET ON (1:3) C.S. CONCRETE SILL(1:2:4)
SECOMASTIC B
C.S.S. CAST IN SITU
MORTAR SEE DETAIL (1) A
20

REV. DESCRIPTION DATE


20
40

IRANIAN PETROLEUM STANDARDS


80

50 50
60

BRICK OR HOLLOW
WALL FINISH AS/FINISH
BLOCK WALL 1:3
SCHED. 50 C.S. AS/ARCH. DRWG.
NO REVISION PERMITTED UNLESS APPROVED BY STANDARD ORGANIZATION
30mm. THK. TRAV. BRICK OR HOLLOW
PANEL SET ON (1:3) C.S. BLOCK WALL SET ON TRAV. PANEL SET ON
(1:3) C.S. MORTAR FIRST CLASS GLAZED
MORTAR 1:3 C.S. MORTAR
WALL TILES AS/FINISH

AS/ARCH. DRWG.
SCHED.
WINDOW SILLS
AS/ARCH. DRWG.
R.C. WINDOW SILLS
TRAV. & MAR. WINDOW SILLS (AT BATHROOMS & KITCHEN) DATE DRAWING No. SHEET REV.
(WITH TRAV. FACING)
1
NOT TO SCALE IPS-D-CE-216 1

You might also like