Hitachi Mini-VRF Catalog
Hitachi Mini-VRF Catalog
Small
Footprint
Big Impact
Variable Refrigerant Flow Systems
Mini VRF Systems for New Construction
and Renovation Projects
MINI VRF
SYSTEMS
–
GO GREEN AND
SAVE SOME GREEN
Hitachi Mini VRF Systems are the energy-efficient A partnership of global leaders at your service
answer for buildings and properties with space
limitations. Hitachi Mini VRF Systems come to you from Johnson
Controls-Hitachi Air Conditioning, a global joint
The Mini VRF System delivers just the right amount venture of Johnson Controls, Hitachi, Ltd., and
of heating and cooling to every space using no more Hitachi Appliances, Inc.
energy than necessary.
When you partner with us, you benefit from proven
The small- footprint outdoor unit combined with VRF technologies backed by two of the industry’s
generous piping limits gives you flexibility to install most trusted companies. Johnson Controls-Hitachi
on rooftops or the ground. And the modular design Air Conditioning is the only North American-
makes indoor unit installation quick and easy with owned VRF equipment producer. We are uniquely
multiple options floor-by-floor and room-by-room. positioned to develop and deploy VRF systems
created without compromise to suit the climate
With both ducted and duct-free indoor units, the conditions, code requirements and technology
Mini VRF System is an excellent choice for both preferences shared by customers in North American
new and retrofit residential and light commercial countries.
applications.
Mini VRF systems offer a host of benefits to you and Enjoy guilt-free comfort
your customers. These small-footprint, modular
systems offer tremendous design flexibility, enabling These compact systems are among the most energy-
you to solve multiple HVAC challenges. And your efficient HVAC options available today, so customers
customers will appreciate the exceptional energy never have to choose between comfort and savings.
savings and individualized comfort they provide.
Variable-speed compressors provide extremely
high part-load efficiency. And the systems
Design with freedom
essentially eliminate the energy loss that occurs in
A variety of standard modular components let you conventional, ducted central systems which may
customize and size equipment to meet specific account for as much as 30% of energy consumption.
project requirements. Because ductwork is generally In fact, these green technology systems can help
needed only for ventilation, ducts can be smaller, customers attain LEED® certification points for
reducing capital cost. Systems can easily be adapted resource efficiency.
as space is reconfigured. There is no need to
remove and replace the original unit or reconfigure Occupants will enjoy unparalleled comfort with
ductwork. Hitachi Mini VRF Systems. Temperature can be set
individually for multiple zones to suit different
Install with ease needs. And, once the temperature is set, the system’s
variable-speed compressors and precise modulation
Hitachi® Mini VRF systems are designed for quick help maintain it within a narrow range, ensuring
and simple installation. Piping from the outdoor consistent comfort. Occupants will also appreciate
units can be connected from the front, back, side, the system’s whisper-quiet operation.
or underneath. Indoor units are relatively small and
light and easy to transport and handle. Service is Plan on years of worry-free service
simple too: systems need little maintenance beyond
changing filters and cleaning coils. Removal of a Hitachi® Mini VRF Systems feature the Hitachi-
single panel provides easy access to all components: designed, high-efficiency scroll compressor. This
control boards, electrical connections, compressor exclusive technology is known for its excellent
and piping. reliability and efficiency and low noise level.
Effective training, intuitive design and selection complete jobs accurately, on time and on budget.
software, advanced logistics and delivery and easily
accessible documentation form a powerful support • Service technicians maintain, troubleshoot and
package that adds substantial value to Hitachi Mini repair systems efficiently.
VRF Systems.
The training centers include a dedicated VRF
laboratory to provide hands-on experience with the
Expert instructors and various systems, components and controls. Videos
hands-on experience for your team and webinars supplement classroom learning on
specific subjects and refresh and enhance the skills
Comprehensive training programs provide
of your design, installation and service teams.
knowledge and skills necessary to effectively and
efficiently deploy Hitachi Mini VRF technology. Our Hitachi Mini VRF training programs help deliver
world-class training centers offer a full VRF course peace of mind that your staff is prepared to support
curriculum with specialized modules and topics that your business with the knowledge to compete in a
help: growing industry.
• D
esigners select and configure the right
equipment easily and accurately.
Expect the right equipment on site All information is available instantly via smartphone
and on time or tablet by scanning the Quick Reference (QR) code
on the product nameplate. The QR code also can be
Ample inventory and advanced order management used to make warranty registration even easier.
and logistics systems can help you complete
installations in a timely manner. Consistent service Let’s go to work – together
and predictable deliveries help you prevent delays
waiting for essential components and enable Hitachi Mini VRF Systems can be configured to meet
you to set a project timeline and schedule labor your project requirements and deliver exceptional
efficiently. Our state-of-the-art main distribution performance. Heat pump units with DC inverter-
center is located in Memphis, Tennessee where UPS driven compressors offer energy savings and the
and FedEx have hubs. This enables us to provide ability to scale to size. Indoor units for ducted or
fast, accurate deliveries and simplifies expedited non-ducted applications offer optional motion
shipments. sensing control for even greater energy savings.
Additional energy savings can be achieved with the
Find information you need 24/7 EconoFresh Economizer Indoor Unit which provides
free-cooling when conditions permit. A host of
Easy access to product information options, controls and accessories help ensure a
helps designers, contractors and custom fit for your project and years of comfort
service personnel work accurately for your customers.
and efficiently. Our secure web
portal, HVACNavigator.com, provides product Enjoy the advantages of working with our team
documentation, technical and service manuals, while bringing the many benefits of Hitachi Mini VRF
troubleshooting guides, brochures, videos, Systems to your customers.
technical support, contact information, and more.
Compact footprint • Ideal for areas with strict lot-line codes • Expands options for positioning outdoor
units
Heat pump VRF systems • Precisely heats or cools multiple zones • Provides extreme system design flexibility
Comprehensive training • Modules tailored to specific job functions • Enables effective equipment selection and
specification
Installation simplicity • Outdoor unit piping can be connected from • Reduces installation time and cost
front, side, back or underneath.
Comprehensive training • Modules tailored to specific job functions • Enables professional, high-quality, timely
installation
MECHANICAL CONTRACTOR / INSTALLER
Consistent, reliable product • Ensures correct components are delivered • Enhances installation efficiency
delivery to job sites on time • Allows efficient labor scheduling
Easy maintenance access • All components easily accessible • Speeds up time spent on maintenance,
repair, and troubleshooting
Single phase power • Flexibility in selection of buildings and • Mini VRF can be used in most light commercial
supply locations and residential applications
• Engineered to deliver the optimum • A leader in the Mini VRF system industry
DC inverter-driven
efficiency • Highest SEER
Compressor
Compressor • Smoothly delivers only the exact • Allows fine control for optimum comfort
amount of refrigerant needed for the
modulation load • Saves energy
Wall-Mount
Floor-Exposed
Floor-Concealed
Tons 0.5 0.7 1.0 1.3 1.5 2.0 2.3 2.5 3.0 4.0 4.5 5.0
1-Way Cassette
Indoor Unit
2-Way Cassette
Indoor Unit
4-Way Mini
Cassette Indoor
Unit
4-Way Cassette
Indoor Unit
Ceiling Suspended
Indoor Unit
Wall Mount
Indoor Unit
Floor Concealed
Indoor Unit
Floor Exposed
Indoor Unit
Ducted Medium
Static Indoor Unit
Ducted Slim
Indoor Unit
EconoFresh
Economizer
Indoor Unit
Multi-Position
Air Handler Unit
Key Features
• Slim and stylish design
• Automatic swing louver distributes airflow evenly for
uniform temperature
• Optional energy saving motion and radiant heat sensor
for optimized airflow and temperature control in
response to room occupancy.
Capacities 6,000 to 15,000 Btu/hr
Nominal Cooling Capacity * Btu / h (kW) 6000 (1.8) 8000 (2.3) 12000 (3.5) 15000 (4.4)
Nominal Heating Capacity * Btu / h (kW) 6700 (2.0) 9000 (2.6) 13500 (4.0) 17000 (5.0)
Outer Dimensions Height in. (mm) 9-1/4 (235) 9-1/4 (235) 9-1/4 (235) 9-1/4 (235)
Width in. (mm) 35-7/16 (900) 35-7/16 (900) 35-7/16 (900) 35-7/16 (900)
Depth in. (mm) 27-15/16 (710) 27-15/16 (710) 27-15/16 (710) 27-15/16 (710)
Refrigerant R410A
Indoor Fan Air Flow Rate cfm 300-265-229-212 335-300-265-229 459-406-353-300 512-459-388-335
Connections
Liquid LIne in. (mm) 1/4 (6.35) 1/4 (6.35) 1/4 (6.35) 1/4 (6.35)
Gas Line in. (mm) 1/2 (12.70) 1/2 (12.70) 1/2 (12.70) 1/2 (12.70)
OD in. (mm) 1-1/4 (32) 1-1/4 (32) 1-1/4 (32) 1-1/4 (32)
Applicable Indoor Unit Model HIC1006B21S and HIC1008B21S HIC1012B21S and HIC1015B21S
NOTES:
* Nominal capacity condition is based on the following conditions. See www.ahrinet.org for more information. ** The sound pressure level is based on the following conditions:
4.9 ft. (1.5m) beneath the units.
COOLING OPERATION CONDITIONS HEATING OPERATION CONDITIONS The above data was measured in an anechoic chamber so that reflected
Indoor Air Inlet Temperature: 80°F DB (26.7°C DB) Indoor Air Inlet Temperature: 70°F DB (21.1°C DB) sound should be taken into consideration in the field.
67°F WB (19.4°C WB) Outdoor Air Inlet Temperature: 47°F DB (8.3°C DB)
Indoor Units
Outdoor Air Inlet Temperature: 95°F DB (35.0°C DB) 43°F WB (6.1°C WB)
Piping Length: 24.6 ft. (7.5m)
Piping Lift: 0ft. (0m)
Key Features
• Nominal capacity of 18 or • Standard integrated condensate
24 MBH DC drain pump with 33-7/16 inch
• Compact design - requires only lift height
Capacities 18,000 to 24,000 Btu/hr 11-3/4” height • Optional energy-saving motion
• Energy-efficient DC fan motor and radiant heat sensor
• Optional air filter box for optimized airflow and
temperature control in response
to room occupancy
Tonnage 1.5 2.0
2-Way Cassette Indoor Unit Model HIC2018B21S HIC2024B21S
Power Supply AC 1 Phase, 208/230V, 60Hz
Refrigerant R410A
Connections
NOTES:
* Nominal capacity condition is based on the following conditions. See www.ahrinet.org for more information. ** The sound pressure level is based on the following conditions:
4.9 ft. (1.5m) beneath the units.
COOLING OPERATION CONDITIONS HEATING OPERATION CONDITIONS The above data was measured in an anechoic chamber so that
reflected sound should be taken into consideration in the field.
Indoor Air Inlet Temperature: 80°F DB (26.7°C DB) Indoor Air Inlet Temperature: 70°F DB (21.1°C DB)
67°F WB (19.4°C WB) Outdoor Air Inlet Temperature: 47°F DB (8.3°C DB)
Outdoor Air Inlet Temperature: 95°F DB (35.0°C DB) 43°F WB (6.1°C WB)
Piping Length: 24.6 ft. (7.5m)
Piping Lift: 0ft. (0m)
Key Features
• H
igh-performance and high- • Optional energy-saving
efficiency heat exchanger motion and radiant heat
• Efficient turbo fan for low- sensor for optimized airflow
noise performance and temperature control in
• Wide range of air flow settings response to room occupancy.
Capacities 8,000 to 18,000 Btu/hr
• Motorized 2-, 3- or 4-channel
air flow louvers with louver kit
Nominal Cooling Capacity* Btu / h (kW) 8,000 (2.3) 12,000 (3.5) 15,000 (4.4) 18,000 (5.3)
Nominal Heating Capacity* Btu / h (kW) 9,000 (2.6) 13,500 (4.0) 17,000 (5.0) 20,000 (5.9)
Height in. (mm) 11-1/4 (285) 11-1/4 (285) 11-1/4 (285) 11-1/4 (285)
Outer
Width in. (mm) 22-7/16 (570) 22-7/16 (570) 22-7/16 (570) 22-7/16 (570)
Dimensions
Depth in. (mm) 22-7/16 (570) 22-7/16 (570) 22-7/16 (570) 22-7/16 (570)
Refrigerant – R410A
Connections
Liquid Line in. (mm) 1/4 (6.35) 1/4 (6.35) 1/4 (6.35) 3/8 (9.52)
Gas Line in. (mm) 1/2 (12.70) 1/2 (12.70) 1/2 (12.70) 5/8 (15.88)
OD in. (mm) 1-1/4 (32) 1-1/4 (32) 1-1/4 (32) 1-1/4 (32)
NOTES:
* Nominal capacity condition is based on the following conditions. See www.ahrinet.org for more information. ** The sound pressure level is based on the following conditions:
4.9 ft. (1.5m) beneath the units.
COOLING OPERATION CONDITIONS HEATING OPERATION CONDITIONS The above data was measured in an anechoic chamber so that reflected
Indoor Units
Indoor Air Inlet Temperature: 80°F DB (26.7°C DB) Indoor Air Inlet Temperature: 70°F DB (21.1°C DB) sound should be taken into consideration in the field.
67°F WB (19.4°C WB) Outdoor Air Inlet Temperature: 47°F DB (8.3°C DB)
Outdoor Air Inlet Temperature: 95°F DB (35.0°C DB) 43°F WB (6.1°C WB)
Piping Length: 24.6 ft. (7.5m)
Piping Lift: 0ft. (0m)
Height in. (mm) 9-3/4 (248) 9-3/4 (248) 9-3/4 (248) 9-3/4 (248)
Outer Dimensions Width in. (mm) 33-1/16 (840) 33-1/16 (840) 33-1/16 (840) 33-1/16 (840)
Depth in. (mm) 33-1/16 (840) 33-1/16 (840) 33-1/16 (840) 33-1/16 (840)
Refrigerant R410A
Connections
Liquid Line in. (mm) 1/4 (6.35) 1/4 (6.35) 1/4 (6.35) 3/8 (9.52)
Gas Line in. (mm) 1/2 (12.70) 1/2 (12.70) 1/2 (12.70) 5/8 (15.88)
OD in. (mm) 1-1/4 (32) 1-1/4 (32) 1-1/4 (32) 1-1/4 (32)
NOTES:
* Nominal capacity condition is based on the following conditions. See www.ahrinet.org for more information. ** The sound pressure level is based on the following conditions:
4.9 ft. (1.5m) beneath the units.
COOLING OPERATION CONDITIONS HEATING OPERATION CONDITIONS The above data was measured in an anechoic chamber so that reflected
Indoor Air Inlet Temperature: 80°F DB (26.7°C DB) Indoor Air Inlet Temperature: 70°F DB (21.1°C DB) sound should be taken into consideration in the field.
67°F WB (19.4°C WB) Outdoor Air Inlet Temperature: 47°F DB (8.3°C DB)
Outdoor Air Inlet Temperature: 95°F DB (35.0°C DB) 43°F WB (6.1°C WB)
Height in. (mm) 11-3/4 (298) 11-3/4 (298) 11-3/4 (298) 11-3/4 (298)
Outer Dimensions Width in. (mm) 33-1/16 (840) 33-1/16 (840) 33-1/16 (840) 33-1/16 (840)
Depth in. (mm) 33-1/16 (840) 33-1/16 (840) 33-1/16 (840) 33-1/16 (840)
Refrigerant 33-1/16
Connections
Liquid Line in. (mm) 3/8 (9.52) 3/8 (9.52) 3/8 (9.52) 3/8 (9.52)
Gas Line in. (mm) 5/8 (15.88) 5/8 (15.88) 5/8 (15.88) 5/8 (15.88)
OD in. (mm) 1-1/4 (32) 1-1/4 (32) 1-1/4 (32) 1-1/4 (32)
P-AP160NA2 P-AP160NAE1
Adaptable Panel Model (applies to all models)
(without Motion and Radiant Heat Sensors) (with Motion and Radiant Heat Sensors)
See notes on page 16 for cooling operation and heating operation conditions.
Key Features
• Optional energy-saving • New fan design for high
motion and radiant heat efficiency and low noise
sensor for optimized • Flexible installation for
airflow and temperature high ceilings
control in response to
Capacities 15,000 to 36,000 Btu/hr room occupancy
Nominal Cooling Capacity * Btu / h (kW) 15,000 (4.4) 24,000 (7.0) 30,000 (8.8) 36,000 (10.5)
Nominal Heating Capacity * Btu / h (kW) 17,000 (5.0) 27,000 (7.9) 34,000 (10.0) 40,000 (11.7)
Height in. (mm) 9-1/4 (235) 9-1/4 (235) 9-1/4 (235) 9-1/4 (235)
Outer
Width in. (mm) 37-13/16 (960) 50 (1270) 62-3/16 (1580) 62-3/16 (1580)
Dimensions
Depth in. (mm) 27-3/16 (690) 27-3/16 (690) 27-3/16 (690) 27-3/16 (690)
Refrigerant R410A
Connections
Liquid Line in. (mm) 1/4 (6.35) 3/8 (9.52) 3/8 (9.52) 3/8 (9.52)
Gas Line in. (mm) 1/2 (12.70) 5/8 (15.88) 5/8 (15.88) 5/8 (15.88)
OD in. (mm) 1-1/4 (32) 1-1/4 (32) 1-1/4 (32) 1-1/4 (32)
NOTES:
* Nominal capacity condition is based on the following conditions. See www.ahrinet.org for more information.
Key Features
• Removable front panel for easy cleaning
• Built-in wireless sensor for use with optional wireless
Capacities: 6,000 to 30,000 Btu/hr zone controller
• Optional condensate pump
Outer Dimensions Width in. (mm) 31-1/8 (790) 31-1/8 (790) 35-7/16 (900)
Refrigerant R410A
Connections
Liquid Line in. (mm) 1/4 (6.35) 1/4 (6.35) 1/4 (6.35)
Gas Line in. (mm) 1/2 (12.70) 1/2 (12.70) 1/2 (12.70)
NOTES:
* Nominal capacity condition is based on the following conditions. See www.ahrinet.org for more information. ** The sound pressure level is based on the following conditions:
COOLING OPERATION CONDITIONS HEATING OPERATION CONDITIONS 3.3ft (1m) Front of the Unit and 3.3ft (1m) Below the Unit..
Indoor Air Inlet Temperature: 80°F DB (26.7°C DB) Indoor Air Inlet Temperature: 70°F DB (21.1°C DB) The above data was measured in an anechoic chamber so that reflected
67°F WB (19.4°C WB) Outdoor Air Inlet Temperature: 47°F DB (8.3°C DB) sound should be taken into consideration in the field.
Outdoor Air Inlet Temperature: 95°F DB (35.0°C DB) 43°F WB (6.1°C WB)
Piping Length: 24.6 ft. (7.5m) Piping Lift: 0ft. (0m)
Height in. (mm) 13-1/8 (333) 13-1/8 (333) 13-1/8 (333) 13-1/8 (333)
Outer Dimensions Width in. (mm) 45-1/4 (1150) 45-1/4 (1150) 45-1/4 (1150) 45-1/4 (1150)
Depth in. (mm) 9-5/8 (245) 9-5/8 (245) 9-5/8 (245) 9-5/8 (245)
Refrigerant R410A
Connections
Liquid Line in. (mm) 1/4 (6.35) 3/8 (9.52) 3/8 (9.52) 3/8 (9.52)
Gas Line in. (mm) 1/2 (12.70) 5/8 (15.88) 5/8 (15.88) 5/8 (15.88)
OD in. (mm) 7/8 (22) 7/8 (22) 7/8 (22) 7/8 (22)
NOTES:
* Nominal capacity condition is based on the following conditions. See www.ahrinet.org for more information. ** The sound pressure level is based on the following conditions:
COOLING OPERATION CONDITIONS HEATING OPERATION CONDITIONS 3.3ft (1m) Front of the Unit and 3.3ft (1m) Below the Unit..
Indoor Air Inlet Temperature: 80°F DB (26.7°C DB) Indoor Air Inlet Temperature: 70°F DB (21.1°C DB) The above data was measured in an anechoic chamber so that reflected
67°F WB (19.4°C WB) Outdoor Air Inlet Temperature: 47°F DB (8.3°C DB) sound should be taken into consideration in the field.
Outdoor Air Inlet Temperature: 95°F DB (35.0°C DB) 43°F WB (6.1°C WB)
Indoor Units
Piping Length: 24.6 ft. (7.5m) Piping Lift: 0ft. (0m)
Key Features
• Compact design for limited spaces
• Provides compatibility with interior designs
• Ideal for perimeter zone air conditioning
Nominal Cooling Capacity * Btu / h (kW) 6,000 (1.8) 8,000 (2.3) 12,000 (3.5) 15,000 (4.4)
Nominal Heating Capacity * Btu / h (kW) 6,700 (2.0) 9,000 (2.6) 13,500 (4.0) 17,000 (5.0)
Height in. (mm) 24-7/16 (620) 24-7/16 (620) 24-7/16 (620) 24-7/16 (620)
Outer
Width in. (mm) 33-3/8 (848) 33-3/8 (848) 38-5/16 (973) 48-1/8 (1223)
Dimensions
Depth in. (mm) 8-11/16 (220) 8-11/16 (220) 8-11/16 (220) 8-11/16 (220)
Refrigerant R410A
Connections
Liquid Line in. (mm) 1/4 (6.35) 1/4 (6.35) 1/4 (6.35) 1/4 (6.35)
Gas Line in. (mm) 1/2 (12.70) 1/2 (12.70) 1/2 (12.70) 1/2 (12.70)
OD in. (mm) 1-1/4 (32) 1-1/4 (32) 1-1/4 (32) 1-1/4 (32)
NOTES:
* Nominal capacity condition is based on the following conditions. See www.ahrinet.org for more information. ** The sound pressure level is based on the following conditions:
COOLING OPERATION CONDITIONS HEATING OPERATION CONDITIONS 3.3 ft. (1m) Front of the Unit and 3.3 ft. (1m) above the floor level.
Indoor Air Inlet Temperature: 80°F DB (26.7°C DB) Indoor Air Inlet Temperature: 70°F DB (21.1°C DB) The above data was measured in an anechoic chamber so that
67°F WB (19.4°C WB) Outdoor Air Inlet Temperature: 47°F DB (8.3°C DB) reflected sound should be taken into consideration in the field.
Outdoor Air Inlet Temperature: 95°F DB (35.0°C DB) 43°F WB (6.1°C WB)
Piping Length: 24.6 ft. (7.5m)
Piping Lift: 0ft. (0m)
Key Features
• 8.7-inch (220 mm) depth preserves room space
• 24.8-inch height leaves ample window space
• Ideal for perimeter zone air conditioning
Nominal Cooling Capacity * Btu / h (kW) 6,000 (1.8) 8,000 (2.3) 12,000 (3.5) 15,000 (4.4)
Nominal Heating Capacity * Btu / h (kW) 6,700 (2.0) 9,000 (2.6) 13,500 (4.0) 17,000 (5.0)
Height in. (mm) 24-13/16 (630) 24-13/16 (630) 24-13/16 (630) 24-13/16 (630)
Outer
Width in. (mm) 41-1/8 (1045) 41-1/8 (1045) 46-1/16 (1170) 55-7/8 (1420)
Dimensions
Depth in. (mm) 8-11/16 (220) 8-11/16 (220) 8-11/16 (220) 8-11/16 (220)
Refrigerant R410A
Connections
Liquid Line in. (mm) 1/4 (6.35) 1/4 (6.35) 1/4 (6.35) 1/4 (6.35)
Gas Line in. (mm) 1/2 (12.70) 1/2 (12.70) 1/2 (12.70) 1/2 (12.70)
OD in. (mm) 1-1/4 (32) 1-1/4 (32) 1-1/4 (32) 1-1/4 (32)
NOTES:
* Nominal capacity condition is based on the following conditions. See www.ahrinet.org for more information. ** The sound pressure level is based on the following conditions:
COOLING OPERATION CONDITIONS HEATING OPERATION CONDITIONS 3.3 ft. (1m) Front of the Unit and 3.3 ft. (1m) above the floor level.
Indoor Air Inlet Temperature: 80°F DB (26.7°C DB) Indoor Air Inlet Temperature: 70°F DB (21.1°C DB) The above data was measured in an anechoic chamber so that
67°F WB (19.4°C WB) Outdoor Air Inlet Temperature: 47°F DB (8.3°C DB) reflected sound should be taken into consideration in the field.
Outdoor Air Inlet Temperature: 95°F DB (35.0°C DB) 43°F WB (6.1°C WB)
Piping Length: 24.6 ft. (7.5m)
Piping Lift: 0ft. (0m)
Indoor Units
Key Features
• High-efficiency AC fan motor
• Multiple fan speed settings
• Up to .74 in. W.G. static pressure
• Bottom access for easy service and troubleshooting
• Built-in condensate pump
Capacities: 15,000 to 54,000 Btu/hr
Ducted High Static Indoor Unit Model HIDH015B22S HIDH018B22S HIDH024B22S HIDH027B22S
Height in. (mm) 11-13/16 (300) 11-13/16 (300) 11-13/16 (300) 11-13/16 (300)
Outer Dimensions Width in. (mm) 27-9/16 (700) 41-5/16 (1050) 41-5/16 (1050) 41-5/16 (1050)
Depth in. (mm) 31-1/2 (800) 31-1/2 (800) 31-1/2 (800) 31-1/2 (800)
Refrigerant R410A
External Pressure High Pressure in. W.G. (Pa) 0.2 (0.4-0.8) 0.2 (0.4-0.8) 0.2 (0.4-0.8) 0.2 (0.4-0.8)
(208/230V)*** Standard in. W.G. (Pa) (50 (100-200)) (50 (100-200)) (50 (100-200)) (50 (100-200))
Connections
Liquid Line in. (mm) 1/4 (6.35) 3/8 (9.52) 3/8 (9.52) 3/8 (9.52)
Gas Line in. (mm) 1/2 (12.7) 5/8 (15.88) 5/8 (15.88) 5/8 (15.88)
OD in. (mm) 1-1/4 (32) 1-1/4 (32) 1-1/4 (32) 1-1/4 (32)
* Nominal capacity condition is based on the following conditions. See www.ahrinet.org for more information. ** The sound pressure level is based on the following conditions:
COOLING OPERATION CONDITIONS HEATING OPERATION CONDITIONS 4.9 ft. (1.5m) beneath the units.
Indoor Air Inlet Temperature: 80°F DB (26.7°C DB) Indoor Air Inlet Temperature: 70°F DB (21.1°C DB) The above data was measured in an anechoic chamber so that reflected
67°F WB (19.4°C WB) Outdoor Air Inlet Temperature: 47°F DB (8.3°C DB) sound should be taken into consideration in the field.
Outdoor Air Inlet Temperature: 95°F DB (35.0°C DB) 43°F WB (6.1°C WB)
*** The data for external pressure indicates Standard Pressure Setting (High
Piping Length: 24.6 ft. . (7.5 m) Pressure Setting 1 - High Pressure Setting 2) values when a filter is not used.
Piping Lift: 0 ft. (0 m) The sound pressure level is based on the Standard Pressure Setting.
Ducted High Static Indoor Unit Model HIDH030B22S HIDH036B22S HIDH048B22S HIDH054B22S
Height in. (mm) 11-13/16 (300) 11-13/16 (300) 11-13/16 (300) 11-13/16 (300)
Outer Dimensions Width in. (mm) 55-1/8 (1400) 55-1/8 (1400) 55-1/8 (1400) 55-1/8 (1400)
Depth in. (mm) 31-1/2 (800) 31-1/2 (800) 31-1/2 (800) 31-1/2 (800)
Net Weight lbs.(kg) 106 (48) 106 (48) 106 (48) 106 (48)
Refrigerant R410A
External Pressure High Pressure in. W.G. (Pa) 0.2 (0.4-0.8) 0.2 (0.4-0.8) 0.2 (0.4-0.8) 0.2 (0.4-0.8)
(208/230V)*** Standard in. W.G. (Pa) (50 (100-200)) (50 (100-200)) (50 (100-200)) (50 (100-200))
Connections
Refrigerant Piping
Liquid Line in. (mm) 3/8 (9.52) 3/8 (9.52) 3/8 (9.52) 3/8 (9.52)
Gas Line in. (mm) 5/8 (15.88) 5/8 (15.88) 5/8 (15.88) 5/8 (15.88)
OD in. (mm) 1-1/4 (32) 1-1/4 (32) 1-1/4 (32) 1-1/4 (32)
* Nominal capacity condition is based on the following conditions. See www.ahrinet.org for more information. ** The sound pressure level is based on the following conditions:
COOLING OPERATION CONDITIONS HEATING OPERATION CONDITIONS 4.9 ft. (1.5m) beneath the units.
Indoor Units
Indoor Air Inlet Temperature: 80°F DB (26.7°C DB) Indoor Air Inlet Temperature: 70°F DB (21.1°C DB) The above data was measured in an anechoic chamber so that reflected
67°F WB (19.4°C WB) Outdoor Air Inlet Temperature: 47°F DB (8.3°C DB) sound should be taken into consideration in the field.
Outdoor Air Inlet Temperature: 95°F DB (35.0°C DB) 43°F WB (6.1°C WB)
*** The data for external pressure indicates Standard Pressure Setting (High
Piping Length: 24.6 ft. . (7.5 m) Pressure Setting 1 - High Pressure Setting 2) values when a filter is not used.
Piping Lift: 0 ft. (0 m) The sound pressure level is based on the Standard Pressure Setting.
Key Features
• High-efficiency AC fan motor
• Multiple fan speed settings
• Up to .74 in. W.G. static pressure
• Bottom access for easy service and troubleshooting
• Built-in condensate pump
Capacities: 6,000 to 54,000 Btu/hr
Ducted Medium Static Indoor Unit Model HIDM006B22S HIDM008B22S HIDM012B22S HIDM015B22S HIDM018B22S
Height in. (mm) 9-13/16 (250) 9-13/16 (250) 9-13/16 (250) 9-13/16 (250) 9-13/16 (250)
Outer Dimensions Width in. (mm) 27-9/16 (700) 27-9/16 (700) 27-9/16 (700) 27-9/16 (700) 41-5/16 (1050)
Depth in. (mm) 31-1/2 (800) 31-1/2 (800) 31-1/2 (800) 31-1/2 (800) 31-1/2 (800)
Refrigerant R410A
External Pressure*** in. W.G. 0.2 (0.4-0.6) 0.2 (0.4-0.6) 0.2 (0.4-0.6) 0.2 (0.4-0.6) 0.2 (0.4-0.6)
Std (Hi-Lo) (Pa) (50 (100-150)) (50 (100-150)) (50 (100-150)) (50 (100-150)) (50 (100-150))
Connections
Liquid Line in. (mm) 1/4 (6.35) 1/4 (6.35) 1/4 (6.35) 1/4 (6.35) 3/8 (9.52)
Gas Line in. (mm) 1/2 (12.70) 1/2 (12.70) 1/2 (12.70) 1/2 (12.70) 5/8 (15.88)
OD in. (mm) 1-1/4 (32) 1-1/4 (32) 1-1/4 (32) 1-1/4 (32) 1-1/4 (32)
* Nominal capacity condition is based on the following conditions. See www.ahrinet.org for more information. ** The sound pressure level is based on the following conditions:
COOLING OPERATION CONDITIONS HEATING OPERATION CONDITIONS 4.9 ft. (1.5m) beneath the units.
Indoor Air Inlet Temperature: 80°F DB (26.7°C DB) Indoor Air Inlet Temperature: 70°F DB (21.1°C DB) The above data was measured in an anechoic chamber so that
67°F WB (19.4°C WB) Outdoor Air Inlet Temperature: 47°F DB (8.3°C DB) reflected sound should be taken into consideration in the field.
Outdoor Air Inlet Temperature: 95°F DB (35.0°C DB) 43°F WB (6.1°C WB)
*** The data for external pressure indicates Standard Pressure Setting
P
iping Length: 24.6 ft. . (7.5 m) (High Pressure Setting 1 - High Pressure Setting 2) values when
Piping Lift: 0 ft. (0 m) a filter is not used. The sound pressure level is based on the
Standard Pressure Setting.
Ducted Medium Static Indoor Unit Model HIDM024B22S HIDM027B22S HIDM030B22S HIDM036B22S HIDM048B22S HIDM054B22S
Height in. (mm) 9-13/16 (250) 9-13/16 (250) 9-13/16 (250) 9-13/16 (250) 9-13/16 (250) 9-13/16 (250)
Outer
Width in. (mm) 41-5/16 (1050) 41-5/16 (1050) 55-1/8 (1400) 55-1/8 (1400) 55-1/8 (1400) 55-1/8 (1400)
Dimensions
Depth in. (mm) 31-1/2 (800) 31-1/2 (800) 31-1/2 (800) 31-1/2 (800) 31-1/2 (800) 31-1/2 (800)
Refrigerant R410A
Air Flow Rate** cfm 759-671-582-494 759-671-582-494 1059-935-812-706 1183-1041-918-777 1271-1112-971-847 1271-1112-971-847
Indoor Fan
(Hi2-Hi-Me-Lo) (m3/min) (21.5-19-16.5-14) (21.5-19-16.5-14) (30-26.5-23-20) (33.5-29.5-26-22) (36-31.5-27.5-24) (36-31.5-27.5-24)
External Pressure*** in. W.G. 0.2 (0.4-0.6) 0.2 (0.4-0.6) 0.2 (0.4-0.6) 0.2 (0.4-0.6) 0.2 (0.4-0.6) 0.2 (0.4-0.6)
Std (Hi-Lo) (Pa) (50 (100-150)) (50 (100-150)) (50 (100-150)) (50 (100-150)) (50 (100-150)) (50 (100-150))
Connections
Liquid Line in. (mm) 3/8 (9.52) 3/8 (9.52) 3/8 (9.52) 3/8 (9.52) 3/8 (9.52) 3/8 (9.52)
Gas Line in. (mm) 5/8 (15.88) 5/8 (15.88) 5/8 (15.88) 5/8 (15.88) 5/8 (15.88) 5/8 (15.88)
OD in. (mm) 1-1/4 (32) 1-1/4 (32) 1-1/4 (32) 1-1/4 (32) 1-1/4 (32) 1-1/4 (32)
* Nominal capacity condition is based on the following conditions. See www.ahrinet.org for more information. ** The sound pressure level is based on the following conditions:
COOLING OPERATION CONDITIONS HEATING OPERATION CONDITIONS 4.9 ft. (1.5m) beneath the units.
Indoor Units
Indoor Air Inlet Temperature: 80°F DB (26.7°C DB) Indoor Air Inlet Temperature: 70°F DB (21.1°C DB) The above data was measured in an anechoic chamber so that reflected
67°F WB (19.4°C WB) Outdoor Air Inlet Temperature: 47°F DB (8.3°C DB) sound should be taken into consideration in the field.
Outdoor Air Inlet Temperature: 95°F DB (35.0°C DB) 43°F WB (6.1°C WB)
*** The data for external pressure indicates Standard Pressure Setting (High
P
iping Length: 24.6 ft. . (7.5 m) Pressure Setting 1 - High Pressure Setting 2) values when a filter is not used.
Piping Lift: 0 ft. (0 m) The sound pressure level is based on the Standard Pressure Setting.
Ducted Slim Indoor Unit Model HIDS006B21S HIDS008B21S HIDS012B21S HIDS015B21S HIDS018B21S
Power Supply AC 1 Phase, 208/230V, 60Hz
Height in. (mm) 7-9/16 (192) 7-9/16 (192) 7-9/16 (192) 7-9/16 (192) 7-9/16 (192)
Outer Dimensions Width in. (mm) 35-3/4 (908) 35-3/4 (908) 35-3/4 (908) 46-3/8 (1178) 46-3/8 (1178)
Depth in. (mm) 17-19/32 (447) 17-19/32 (447) 17-19/32 (447) 17-19/32 (447) 17-19/32 (447)
Refrigerant R410A
External Pressure *** in. W.G. 0.04 (0.12-0.00) 0.04 (0.12-0.00) 0.04 (0.12-0.00) 0.04 (0.20-0.00) 0.04 (0.20-0.00)
Std (Hi-Lo) (Pa) (10 (30-0)) (10 (30-0)) (10 (30-0)) (10 (50-0)) (10 (50-0))
Connections
Liquid Line in. (mm) 1/4 (6.35) 1/4 (6.35) 1/4 (6.35) 1/4 (6.35) 3/8 (9.52)
Gas Line in. (mm) 1/2 (12.70) 1/2 (12.70) 1/2 (12.70) 1/2 (12.70) 5/8 (15.88)
OD in. (mm) 1-1/4 (32) 1-1/4 (32) 1-1/4 (32) 1-1/4 (32) 1-1/4 (32)
NOTES:
* Nominal capacity condition is based on the following conditions. See www.ahrinet.org for more information.
COOLING OPERATION CONDITIONS HEATING OPERATION CONDITIONS ** The sound pressure level is based on the following conditions:
Indoor Air Inlet Temperature: 80°F DB (26.7°C DB) Indoor Air Inlet Temperature: 70°F DB (21.1°C DB) \4.9 ft. (1.5m) beneath the units.
67°F WB (19.4°C WB) Outdoor Air Inlet Temperature: 47°F DB (8.3°C DB) The above data was measured in an anechoic chamber so that
reflected sound should be taken into consideration in the field.
Outdoor Air Inlet Temperature: 95°F DB (35.0°C DB) 43°F WB (6.1°C WB)
Piping Length: 24.6 ft. . (7.5 m)
Piping Lift: 0ft. (0m) *** The data for external pressure indicates Standard Pressure Setting
(High Pressure Setting 1 - High Pressure Setting 2) values when a
filter is not used. The sound pressure level is based on the Standard
Pressure Setting.
Key Features
• Excellent for applications with cooling demand during mid seasons
and winter
• Inputs for optional CO2 and enthalpy sensors are available for control
based on indoor air quality or humidity
The EconoFresh unit includes the Economizer Kit
and a Ducted Medium Static Unit in your choice of • A remote control switch allows control of the outside air damper
three capacities: 30,000, 36,000 or 48,000 Btu/hr. opening to ensure minimum outside airflow requirements are met
Outer Dimensions Width in. (mm) 58-1/16 (1474) 58-1/16 (1474) 58-1/16 (1474)
Piping Length: 24.6 ft. (7.5m)
Depth in. (mm) 23-5/8 (600) 23-5/8 (600) 23-5/8 (600) Piping Lift: 0 ft. (0m)
Connections
Liquid Line in. (mm) 3/8 (9.52) 3/8 (9.52) 3/8 (9.52)
Gas Line in. (mm) 5/8 (15.88) 5/8 (15.88) 5/8 (15.88)
Indoor Units
Multi-Position Air Handler with DX-Kit HMAHP18B21S HMAHP24B21S HMAHP30B21S HMAHP36B21S HMAHP36C21S
Height in. (mm) 41 (1041) 41 (1041) 47-1/2 (1207) 47-1/2 (1207) 51-1/2 (1308)
Outer Dimensions Width in. (mm) 17-1/2 (445) 17-1/2 (445) 17-1/2 (445) 17-1/2 (445) 21 (533)
Depth in. (mm) 27-7/16 (545) 27-7/16 (545) 27-7/16 (545) 27-7/16 (545) 27-7/16 (545)
Net Weight lbs (kg) 85 (39) 87 (40) 113 (51) 113 (51) 114 (52)
Refrigerant R410A
Air Flow Rate*2 cfm 576-382 / 687-500 713-457 / 778-605 843-677 / 917-769 1108-968 / 1178-1057 1110-877 / 1186-974
Indoor Fan (208/230V)
3
(Hi-Lo) (m /min) (16-11) / (19-14) (20-13) / (22-17) (24-19) / (26-22) (31-27) / (33-30) (31-25) / (34-28)
Liquid Line in. (mm) 3/8 (9.52) 3/8 (9.52) 3/8 (9.52) 3/8 (9.52) 3/8 (9.52)
Refrigerant Piping
3
Gas Line * in. (mm) 5/8 (15.88) 5/8 (15.88) 5/8 (15.88) 5/8 (15.88) 5/8 (15.88)
OD in. (mm) 1-1/16 (26.7) 1-1/16 (26.7) 1-1/16 (26.7) 1-1/16 (26.7) 1-1/16 (26.7)
Condensate Drain
ID in. (mm) 13/16 (20.9) 13/16 (20.9) 13/16 (20.9) 13/16 (20.9) 13/16 (20.9)
Height in. (mm) 3-3/16 (81.0) 3-3/16 (81.0) 3-3/16 (81.0) 3-3/16 (81.0)
Outer Dimensions Width in. (mm) 12-5/8 (320) 12-5/8 (320) 12-5/8 (320) 12-5/8 (320)
Depth in. (mm) 7-3/8 (187) 7-3/8 (187) 7-3/8 (187) 7-3/8 (187)
Net Weight lbs. (kg) 6.57 (2.98) 6.57 (2.98) 6.57 (2.98) 6.57 (2.98)
Height in. (mm) 4-5/16 (109) 4-5/16 (109) 4-5/16 (109) 4-5/16 (109)
Outer Dimensions Width in. (mm) 17-1/16 (433) 17-1/16 (433) 17-1/16 (433) 17-1/16 (433)
Depth in. (mm) 5-5/16 (151) 5-5/16 (151) 5-5/16 (151) 5-5/16 (151)
Net Weight lbs. (kg) 8.84 (4.01) 8.84 (4.01) 8.84 (4.01) 8.84 (4.01)
Refrigerant R410A
Liquid Line In in. (mm) 3/8 (9.52) 3/8 (9.52) 3/8 (9.52) 3/8 (9.52)
Refrigerant Piping
Liquid Line Out in. (mm) 3/8 (9.52) 3/8 (9.52) 3/8 (9.52) 3/8 (9.52)
NOTES:
* . Nominal capacity is based on combination with VRF system and following conditions:
COOLING OPERATION CONDITIONS HEATING OPERATION CONDITIONS ** Sound pressure leavel is currently not available.
Indoor Air Inlet Temperature: 80°F DB (26.7°C DB) Indoor Air Inlet Temperature: 70°F DB (21.1°C DB) *** Hi and Lo setting on the wired controller. (Hi = Air Handler's High tap and
67°F WB (19.4°C WB) Outdoor Air Inlet Temperature: 47°F DB (8.3°C DB) Lo = Air Handler's Medium tap). Make sure both the external pressure and
Outdoor Air Inlet Temperature: 95°F DB (35.0°C DB) 43°F WB (6.1°C WB) air flow rate match the specification.
**** Gas connection piping diameter of the air handler is changed by using the
Piping Length: 24.6ft (7.5m) Piping Lift: 0ft. (0m) reducer (accessory of DX-Kit) to connect to VRF system.
Multi-Position Air Handler with DX-Kit HMAHP48C21S HMAHP48D21S HMAHP60C21S HMAHP60D21S HMAHP60D22S
Height in. (mm) 51-1/2 (1308) 55-1/2 (1410) 55-3/4 (1416) 55-1/2 (1410) 55-1/2 (1410)
Outer Dimensions Width in. (mm) 21 (533) 24-1/2 (622) 21 (533) 24-1/2 (622) 24-1/2 (622)
Depth in. (mm) 27-7/16 (545) 27-7/16 (545) 27-7/16 (545) 27-7/16 (545) 27-7/16 (545)
Net Weight lbs (kg) 150 (68) 153 (69) 146 (66) 170 (77) 170 (77)
Refrigerant R410A
Air Flow Rate*2 cfm 1062-971 / 1190-1059 1391-1139 / 1481-1258 1680-1562 / 1739-1659 1701-1590 / 1779-1694 1757-1639 / 1829-1735
Indoor Fan
(Hi-Lo) (m3/min) (30-28) / (34-30) (39-32) / (42-36) (48-44) / (49-47) (48-45) / (50-48) (50-46) / (52-49)
Liquid Line in. (mm) 3/8 (9.52) 3/8 (9.52) 3/8 (9.52) 3/8 (9.52) 3/8 (9.52)
Refrigerant Piping
Gas Line *3 in. (mm) 5/8 (15.88) 5/8 (15.88) 3/4 (19.05) 3/4 (19.05) 3/4 (19.05)
OD in. (mm) 1-1/16 (26.7) 1-1/16 (26.7) 1-1/16 (26.7) 1-1/16 (26.7) 1-1/16 (26.7)
Condensate Drain
ID in. (mm) 13/16 (20.9) 13/16 (20.9) 13/16 (20.9) 13/16 (20.9) 13/16 (20.9)
Refrigerant R410A
NOTES:
* . Nominal capacity is based on combination with VRF system and following conditions:
COOLING OPERATION CONDITIONS HEATING OPERATION CONDITIONS ** Sound pressure leavel is currently not available.
Indoor Air Inlet Temperature: 80°F DB (26.7°C DB) Indoor Air Inlet Temperature: 70°F DB (21.1°C DB) *** Hi and Lo setting on the wired controller. (Hi = Air Handler's High tap and
67°F WB (19.4°C WB) Outdoor Air Inlet Temperature: 47°F DB (8.3°C DB) Lo = Air Handler's Medium tap). Make sure both the external pressure and
Outdoor Air Inlet Temperature: 95°F DB (35.0°C DB) 43°F WB (6.1°C WB) air flow rate match the specification.
**** Gas connection piping diameter of the air handler is changed by using the
Piping Length: 24.6ft (7.5m) Piping Lift: 0ft. (0m) reducer (accessory of DX-Kit) to connect to VRF system.
* For more details and limitations, please consult Hitachi sales team or refer to product manuals
Main Refrigerant Gas Line in (mm) 5/8 (15.88) 5/8 (15.88) 5/8 (15.88)
Piping Liquid Line in (mm) 3/8 (9.52) 3/8 (9.52) 3/8 (9.52)
NOTES:
* Rating Conditions: ** Efficiency ratings are based on the AHRI 210/240 test standard.
COOLING Indoor Air Inlet Temperature: 80°F (26.7°C)DB
*** There are some exceptions and notes for cooling and cooling operation ranges.
67°F (19.4°C)WB For details, refer to Section 2.12 “Operation Range”.
Outdoor Air Inlet Temperature: 95°F (35.0°C)DB
**** Measurement Point: 3.3 ft. (1m) from the air outlet side, 4.9 ft. (1.5m) from floor level. The operation
HEATING Indoor Air Inlet Temperature: 70°F (21.1°C)DB sound is measured in an anechoic chamber. However, the actual operation sound may appear louder or
Outdoor Air Inlet Temperature: 47°F (8.3°C)DB with an echo because of surrounding environmental noise. Be sure to check environmental conditions
43°F (6.1°C)WB before installation. The sound of the air inlet side may be 3dB higher than that of the air outlet side.
Piping Length: 24.6in. (7.5m)
Piping Lift: 0ft. (0m)
Hitachi Mini VRF Systems offer a wide range of control Simplified Wired Zone Controller
systems to suit multiple applications including wired and Programmable Wired Zone Controller
wireless controllers that manage zones and central stations Wireless Zone Controller
for central control of the entire system. VRF Smart Gateway Centralized Controllers
(BACnet)® and LONWorks® Adapters provide control through VRF Smart Gateway (BACnet)
LONWorks® Adapter
building automation systems.
Computerized
Simplified Mini Large Central Web-Enabled VRF Smart
Project Requirements Wired Wired Wireless Central Central Controller Central Gateway LONWorks®
Controller Controller Controller Station Station (CCCS01/ Controller (BACnet)® Adapter
(CIS01) (CIW01) (CIR01) (CCM01) (CCL01) CCCA01) (CCWEB01) (CBN02) (CLW01)
Advanced multi-zone
control of small to medium 4 4 4 n n
size projects
Advanced multi-zone
control of large commercial 4 4 n n
projects
Automatic cooling/heating
changeover for heat pump 4 4 4 4 4 4 4 n n
systems
Temperature set-point
range restrictions 4 4 4 4 4 4 n n
Wi-Fi enabled n n
Easy integration n n
Easy commissioning n n
4 = Native application or feature of this device n = Dependent upon capabilities of a third party energy management system * = Additional metering hardware is required for consumption-based tenant billing
ZONE CONTROLLERS
Energy-Saving Features
Setback
MODEL CIS01
Central Station
Mini and large systems are available.
Control up to
Compatible with the Control up to
H-LINK II 160 indoor units 32 64
or groups
Connect up to
8 stations
(model dependent)*
The VRF Smart Gateway enables unprecedented control of Hitachi VRF System
components through fast, simple integration into the Facility Explorer® BAS.
Complete system data is available for all components in the system.
Enhanced Features
• Automatically structures and • B ACnet® compatible
organizes data for faster, easier • Information conforms to BAS
and less costly integration conventions for quick adoption
• Works over Ethernet to obtain • Wi-Fi accessibility enables
system data and make it accessible 24/7 monitoring and control of
through BAS equipment from laptops, tablets MODEL CBN02
• Brings all BMS capabilities to and smartphones
VRF components including
User Interface, Global Search,
schedules, reporting, and offline
configuration
LONWorks® Adapter
Features
• 24V AC powered • Support for the following maximum device limits:
• Connect up to 4 LonWorks Adapters (CLW01) • 64 Refrigerant Systems
simultaneously to the same H-LINK II segment • 160 Indoor Units
• Connect up to 8 Large (CCL01) and/or Mini (CCM01) • Total of 200 nodes:
Central Controllers and/or LONWorks Adapters (CLW01) A combination of up to 160 indoor units and
simultaneously to the same H-LINK II segment a maximum of 64 outdoor units, not to exceed
a total of 200.
H-LINK II
H-LINK II System
H-LINK II is a unique communication system that can be used to control
multiple outdoor and indoor units from one control point. Its use assists Max. Number of Refrigerant
64
installers and service engineers by simplifying commissioning and service Groups / System
maintenance. For building owners and occupants, it provides great versatility
Address Setting Range of
to connect various types of central control options enabling better system Indoor Units / 0 to 63
management. Refrigerant Group
Max. Number of Indoor Units /
The H-LINK II communication system for connection between outdoor and System
160
indoor units provides an extended system configuration and improved
functions without sacrificing workability and flexibility. Total Number of Devices in the
200
same H-LINK II
Our proprietary high-performance communication system enables
connection of control wiring between indoor and outdoor units, and between Total Max. Wiring Length Total 3,281 ft
a centralized control system and indoor/outdoor units across two or more
refrigerant systems.
Controllers
Toppling Prevention Tool Prevents OU from tipping over when Snow Protection Hood is in use
3-Pin Connector Cable Kit that provides remote start/stop capability for IU and operating status of IU functions
Kit (with 5 sets of 3P Connectors) that provides remote start/stop capability (binary input) to IU and operating status
3-Pin Connector Cable
(binary input) of IU functions
Relay and 3-Pin Connector Kit Relay and 3 Pin Connector Kit used for input/output signals (ON/OFF, mode, alarm) between central controller and IU
Ducted Indoor Units
Remote Temperature Sensor Remote air temperature sensor
Fresh Air Intake Kit Kit for connection of outside air to the IU
T-Tube Connecting Kit Kit for connection of outside air duct to the IU. Requires Fresh Air Intake Kit
Grille for Front Discharge Grille used for front air outlet from IU
Drain pump (wall mount) Condensate Pump Kit Capacity - 2.9-3.2 GPH @ 0’ Head / 1.2-1.6 GPH @ 33’ Head
Kit (with 5 sets of 3P Connectors) that provides remote start/stop capability (binary input) to IU and operating status
3-Pin Connector Cable
(binary input) of IU functions
Relay and 3-Pin Connector Kit Relay and 3 Pin Connector Kit used for input/output signals (ON/OFF, mode, alarm) between central controller and IU
Industry certified
Hitachi VRF Systems are Intertek ETL Listed
(Canada & USA), signifying that they comply with the standard of Heating and Cooling
Equipment (ANSI/UL 1995 and CAN/CSA C22.2 No. 236-11, 4th Edition, October 14, 2011).
The systems are also certified by the Air Conditioning, Heating & Refrigeration Institute.
WARRANTY
For more details on terms, conditions, and limitations, please refer to the warranty certificate.
Contact your sales person or visit our warranty support center at [email protected] for
specific eligibility requirements.
The specifications of this catalog may change without prior notice to allow Hitachi Cooling &
Heating to incorporate the latest innovations for its customers. The information contained in
this catalog is merely informative. Hitachi Cooling & Heating declines any responsibility in the
broadest sense, for damage, direct or indirect, arising from the use and / or interpretation of the
recommendations in this brochure.