F6 L20.L10 AC100V 5A Car light curtain safety touch panel and hall light power switch
Code Description
BD CPU-BD Signal
Electric order
#21 Open the door #20 Close the door B4Z Control brake
Code Description
LS12 Circumference limit switch 21R1U Upper level sensor GV Speed limiter switch
LS11 Terminal switch on the hoistway 21R3U Upper door sensor OBS Car buffer switch
LS101 Upper deceleration switch I 21R3D Lower door sensor OBS-C Counterweitgh buffer switch
LS102 Upper deceleration switch II 21R1D Lower level sensor TPS-C Tensioner switch
LS202 Lower deceleration switch II 3MS Well position switch CFM Safety clamp switch
LS201 Lower deceleration switch I 3R-YS Refuge sensor CEH Safety window switch
LS21 Downhole terminal switch CLG Car door switch OTL Door opener switch
LS22 Downhole limit switch CLS Hall door interlock switch CTL Door closing switch
LC1 Weighing 4WC Overload switch SSS Car door light curtain switch
CMU Upper car to station lock BZ Bee bell CMD Lower part of car to station lock
AR2 Power failure AC input ARM ARM Signal DOH Open door extension indicator
LS1M Well up limit CFM Car top emergency stop switch PG1 Encoder
1. Operation method
Operating item Start operation Running operation LED Display End operation
Seismic reset Press and hold BTN3 for more than 4 seconds
Extend the door Open the EQDO switch to the door and open it completely
Slow train operation Press the EQDO switch up while holding down BTN3 Rise when holding down BTN1
Call login Turn the EQDO switch up while holding down BTN2 Press BTN1 to go up 1 level Press
BTN3 layer, continuously press the top/ bottom
Login layer
FD Operation Rotate the SEL to 2 while holding down BTN2, release BTN2 Press and hold BTN1/3 to close
the door Then let the elevator start after the elevator starts FD dedicated mode Press and hold
BTN2 for more than 4 seconds
AJ Running
No load Rotate the SEL to 3 while pressing BTN2, release BTN2 The elevator automatically opens after
pressing BTN1/3
Start running
AJ Dedicated mode
Full load Rotate the SEL to 14 while pressing BTN2, release BTN2 The elevator automatically opens after
pressing BTN1/3
Start running
Intermediate load Rotate the SEL to 5 while pressing BTN2, release BTN2 Elevator automatically opens
after pressing BTN1/3
Start running
Dedicated operation Release the SEL to F while pressing BTN2, release BTN2 The hall button is invalid, use the
sedan button registration, Press and hold the close button to start after closing the door Display
corresponding to the SEL position
Confirmation and operation: Press the button to confirm, press the upper button for 4 seconds to extinguish
the light to 00 and then press the count
(see below)
Display in binary
Bit 4 Interrupt communication with SV Interrupted with the main SV Normal communication with SV
Bit 3 Interrupted communication with hall Some halls are disconnected Normal communication with hall
Bit 2 Start prohibition High speed operation prohibition High speed operation
Bit 1 Door opening position Middle operation of the door Door closed position
Bit 0 Within the opening area Outside the door opening area
5. SEL and LED data number content
Hexadecimal number
Bit Adjustment status (0.1) Encoder (1.1) 21R (3.0) LS (3.1) Control (3.2)
Door input (3.3)
7 Run up LS101 OTL
6 Run up LS102 CTL
5 Run up LS103 Lock ladder DBD
4 Run down Self-generated
3 Motor up 21R1D Fire Safety touch panel
2 Motor up 21R3D LS203 Earthquake (extra low) Photocell
1 AJ running Motor running down 21R3U LS202 Earthquake (low) Open button
0 FD running/ finished* Motor running down 21R1U LS201 Earthquake (high) Close button
Bit Running speed (6.0) Running speed (6.1) Dynamometer voltage (8.0) %load (8.1)
7
10m/min bit
0-F Binary Light up/+light
10% bit
0-F Binary
6
1V bit
0-9 binary display
5 D400 90m/min or more
4 D300 60m/min or more
3 D203 45m/min or more
1m/min bit
0-9 binary
0. 1V bit
0-9 binary display 1%bit
0-9 binary
PMC can be used to check the % information address 3F02 INT
2 D202 18m/min or more
1 D201 6m/min or more
0 D200 0.5m/min or more
6. The correspondence between the operation mode and the displayed value: Data number (2.0) (can also be
confirmed with PMCY2180 BYTE)
Display Operating mode Display Operating mode Display Operating mode
00 Completely rested 14 High speed prohibition 2F Dedicated operation
01 Running switch OFF 15 High speed prohibition to open the door 2F VIP Operation
03 Start prohibition 20 Fire control operation 33 VIP Layer call back
09 Installation and operation 28 Special fire operation 37 Running with driver
0A Car top manual operation 29 Secondary fire operation 3C Fully automatic operation
0F Manual operation in the car 2A AJ Running
13 FD Operation 2D Temporary operation
A. Correspondence between input/ output points and line numbers (NEW EXDN ii)
00
2100 Line number JQ-B7 JM-B2 JM-B1 CP28
Element PW 21R1D 21R1U
01
2101 Line number JL-A10 JL-A9
Element FAC AR2
02
2102 Line number H2-A4 H1-A4 H2-B4 H1-B4 H2-A5 H1-A5 H2-B5 H1
-B5 IF61
ID=0
Element LS204 LS104 LS203 LS103 LS202 LS102 LS201 LS101
03
2103 Check point *K *I *H *D *E *C *B *A IF61
ID=0
CP13 CP12 P6 P14A P14B CP18 CP15 CP16
Element #6Z Run monitoring 1E Car
With STOP 1E Peripheral safety SW circuit 21R3U
Opening area 21R3D
Surveillance HS switch door monitoring CLG
Car door #CHK Power monitoring
04 2104 Line number H2-A6 H1-A6 JR-A2 JR-B3 C3-A7 *J *G *F
P18 P17 B20A B50 L41C P1
Element LS21
Lower terminal LS11
5, (DCL-33 door machine) 72: Door control device abnormality (DBD) detection
Analysis: E/C INFO PHASE POS TIME
72 30 4 15 11/15 7: 0: 59
72 30 4 15 11/15 7: 1: 8
72 30 4 15 11/15 7: 1: 17
5F 21 98 15 11/15 7: 1: 17
Isolated condition: (1) Door opening and closing action, check out the DBD signal OFF for 0.5 seconds
(2) The inverter trips (#ALARM-30B, OFF between 30C)
(3) IF78 detects motor overspeed
INFO: Floor number
Post-detection action: stop after 3 consecutive occurrences
Counter measures: (1) AC200 power supply voltage confirmation and confirm that the short – circuit plug
JC of the IF78 has been removed.
(2) Confirm that the value of F29 is 4
(3) F32 (output torque) increased by +30
(4) F44 (fault detection time) increased from 0.1 second to 0.15 second
(5) Increase strong wind countermeasures: F62 ------ 0 (invalid) 1 (valid)
CALL RECORD
Start: Press the button, also cut the EQDO switch to ON, then let go.
Implementation: Press the button, the above (press and hold for more than 2 seconds, item layer)
is reserved.
Press the down button, the lower layer (press and hold for more than 2 seconds, the bottom layer) is
reserved.
Press and hold the middle button, the above reserved floor is recorded.
Keep pressing the middle button, the door will be closed
End: Cut the EQDO switch to OFF
Expressed as –1—2—3—4--5—6—7—8—9—10—11—12……
Usually indicates the display of the LED when SEL=0 data=0
Light
High speed flashing
Flashing at low speed
Bit7
Project code
….
….