Caution !: If Your Lift System Uses

This document provides instructions for proper installation and use of an MLKS10 Emergency Rescue System for lifts. Key steps include: 1) Affixing caution stickers to the control panel and machine room entrance. 2) Configuring the motor protection relay and safety circuit connections. 3) Using a 4-pole fuse for the lift wiring and connecting the safety circuit to one pole. The document then details programming the MLKS10 control board, including accessing programming mode and adjusting parameters such as maximum movement time, start delay, motor frequency, and automatic door settings. Wiring diagrams are also provided.

Uploaded by

An as akras
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
201 views4 pages

Caution !: If Your Lift System Uses

This document provides instructions for proper installation and use of an MLKS10 Emergency Rescue System for lifts. Key steps include: 1) Affixing caution stickers to the control panel and machine room entrance. 2) Configuring the motor protection relay and safety circuit connections. 3) Using a 4-pole fuse for the lift wiring and connecting the safety circuit to one pole. The document then details programming the MLKS10 control board, including accessing programming mode and adjusting parameters such as maximum movement time, start delay, motor frequency, and automatic door settings. Wiring diagrams are also provided.

Uploaded by

An as akras
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 4

! CAUTION !

If your Lift System uses,


MLKS10 Emergency Rescue System
you must do the below applications.

¾ One of the caution stickers given by Mikrolift


must sticked on CONTROL PANEL, and the
other one must sticked on a place can be seen
at the MACHINE ROOM enter.

¾ In the Control Panel; Motor Protection (Main


Thermal Relay) must have appendix open
contact and SAFETY CIRCUIT must be passed
on from this contact.

¾ W-automat fuse that belongs to lift in electric


panel at machine room must be used 4 POLE
and SAFETY CIRCUIT must be connected to
one of these poles as serial (KG1-KG2).
MLKS10-S PROGRAMMING (Ver:1.3)
• To enter to programming, first battery fuse must taken to ‘‘OFF’’ position. 55V
supply voltage of MLKS10 board is cut off, when the voltage is applied again by
pressing ENTER button for 2 seconds, programming mode starts.
Program No Program Name

00:Max.Mov.Time 00:Max.Mov.Time
20 Seconds -> 20 Seconds
Registered Parameter Value When this sign on screen
parameter value can be changed.
• You can choose any program by using UP and DOWN buttons.
• To exit the programming mode ESC button in the main menu is used, ‘‘Exit Program’’
is displayed on LCD screen. Press the ENTER button and exit the programming mode;
to return the main menu again press the ESC button.
• When ENTER button in the main menu is pressed, the program on the screen starts.
• If the program has parameter, an arrow appears at the beginning of the second line of
LCD screen. You can change the parameter value by using UP and DOWN buttons.
To store the value, press the ENTER button and return the main menu. By pressing the
ESC button the registered value is valid and you can return the main menu. If the
program is a function, it is run and ‘‘Okey’’ appears on LCD screen.
Program Factory Set Parameters / Explanations
00:Max.Mov.Time 20 Seconds 10-200 Seconds
(Chosing maximum movement time)
01:Start Delay 05 Seconds 00-100 Seconds
(Chosing waiting time before rescue)
02:JFMove.Time 0,0 Second 0,0-10,0 Seconds
(In speed control systems, chosing the needed movement time
to reach the floor after detected limit switch)
03:JFCont.Select OpenAtFloor OpenAtFloor - ClosedAtFloor
(chosing levelling bi-stable switch information)
04:FirstMov.Dir. Up Up - Down
(Chosing first movement direction)
05:Mot.Frequency 6,0 Hz 3,0-10,0 Hz
(Chosing motor frequency)
06:Auto.DoorType Single Phase Single Phase – Three Phase – ContactOutput
(Chosing automatic door type)
07:A.DoorOpenT. 05 Seconds 00-30 Seconds
(Chosing automatic door opening time)
08:LockWaitTime 10 Seconds 02-30 Seconds
(Chosing waiting time to come lock signal)
09:ConnectType Internal Internal - External
(Chosing the connection type of the card as internal or
external)
10:High Torque 02 Seconds Passive, 1-5 Seconds
(After opening the mechanical brake, time selection that will
be reached to set motor frequency beginning from 1 Hz)
10:MotionControl Active Passive - Active
(Working inside panel,controlling of KM contactor drop)
98:Language English Turkce - English
20:Factory Set ? (All parameter values are changed into factory settings)
CAUTION : These cables must be 2,5mm² NYAF !

GROUND FAULT PROTECTED


2A

220V AC
AUTOMAT FUSE
GROUND

-180
+180

AKU+
AKU-
U V W 55VAC 4A
220V

55V AC
KP

AP

220V AC
37V
FOR AUTOMATIC DOOR

AN 35A / 1000V
MLKS10 4A
0
LCD VER-1 AC +

18V AC
EXO1
EXO2
840A
840B
T220

TO MLAUTO-E

RNO
RNK
RNA
TMP

KM1
KM2

EXT
KA1
KA2
T37

869
142
--
KP

R S T MP AC AUTOMATIC DOOR CARD

24V DC Bridge

TO MLAUTO-E
35A / 1000V AUTOMATIC DOOR CARD
RU1
-- AC
RU2 CON1
+ AC

100
1000

EO1
PTC
AUTO
SO ENB MP R S T
Cam Bridge 1
KM 2
LIR1
KP
LIR2
ML20ES
1* 1* VER-1
KP KM ENTER
KM
RF
KM
RH
1*
RU2
RH
RF RU1
KP 11
LCD

ESC
1* 10B
RF 140
RH
KM 130
KP

EIN1
EIN2
KRC
120
RU1 RU2 1*
10A
RU1 CON2
RU2
FLAT CABLE 16

KP 1*
RU2 RF RH RU2 RU1
RU1
KP

RH RF
FLAT CABLE 16

RH

Brake Bridge
35A / 1000V

Mechanical
RF
MOTOR PROTECTION

AC

AC
THERMAL RELAY

KP : MAIN CONTACTOR TO SAFETY CIRCUIT


+ CONECTIONS
--

KM : MOTOR CONTACTOR

CONTROL PANEL EMERGENCY


STOP BUTTON
RU1

RU2

10A (AN) 6A
TO MLAUTO-E 2* 2* CON2 CON1

142
500
501
869P
869K
AUTOMATIC DOOR CARD MLKLME
(AP)
VER-1

408
407
406
405
404
403
402
401
869
501
500
818
817
142
804

031
032

190
M0

2G
02

12
A B C D E F G

100
1000
P1
P2
110
120
130
140
T

1F
R

KG1
KG2

U1
V1
W1

U2
V2
W2

810
2001
1
2

2000
840
S
MP
+

BATTERY
HIGH LOW

1* Contactors must be of AC-3 class with 220VAC coils !


SPEED SPEED
ML20E VERSION : 1.1
TWO SPEED CONTROL PANEL CONNECTIONS
RC filters must connected across the coils of contactors ! MIKROLIFT DATE : 30.01.2010 WITH MLKS10 EMERGENCY RESCUE SYSTEM
( FOR SINGLE PHASE AUTOMATIC DOOR MOTOR )
2* These contacts must be the main contacts of RU1 and RU2 contactors !
MUHENDISLIK SCHEME NO : ML20E_09
CAUTION : These cables must be 2,5mm² NYAF !

GROUND FAULT PROTECTED


AUTOMAT FUSE 2A

220V AC
GROUND
-180
+180

AKU+
4A

AKU-
U V W 55VAC
TO AUTOMATIC DOOR
220V
CONNECTIONS

55V AC
KP

AP

220V AC
37V
FOR AUTOMATIC DOOR

AN 35A / 1000V
MLKS10 4A
0
LCD VER-1 AC +

18V AC
EXO1
EXO2
840A
840B
T220

RNO
TMP

RNK
RNA
KM1
KM2

EXT
KA1
KA2
T37

869
142
--
KP

R S T MP AC
24V DC Bridge

35A / 1000V
RU1
-- AC

RU2 CON5
+ AC RYA

SD
SC

PTC
100
1000

SB
SA
MP R S T

SO
RML3
RE
OUT1
OUT2
OUT3
OUT4
Cam Bridge RYB
RTO
RT COM
KP K15
RTC
1* 1* K5
2
KP KM KM 1 K3
KM
LIR1
1* LIR2 K16
RXA K19
RH
RF KM RXB
LCD ENTER
KP
1*
RF ML60XS
RH VER-1
RF RU2
RH
RU1
KM 11 ESC
KP
1* 10B
RU1 RU2 140
RU1
RU2 130

EIN1
EIN2
EIN3
KRC

ML1
ML2
120

ST
10A CON2 CON3
KP 1*
RU2
RU1 RF RH RU2 RU1
KP

RH RF FLAT CABLE 16

FLAT CABLE 16
RH

Brake Bridge
Mechanical
35A / 1000V
RF
MOTOR PROTECTION

AC

AC
THERMAL RELAY

KP : MAIN CONTACTOR FLAT CABLE 16


+
--

TO SAFETY CIRCUIT
KM : MOTOR CONTACTOR CONNECTIONS

CONTROL PANEL EMERGENCY


STOP BUTTON
RU1

RU2

(AN)
10A TO AUTOMATIC DOOR 6A
CON2 CON3 CON5 MLKLMX
CONNECTIONS 2* 2* VER-1

142
500
501
869P
869K
(AP)

DTS

2BC
K20

X16
X15
X14
X13
X12
X11
X10
X09
X08
X07
X06
X05
X04
X03
X02
X01
142
141

804
805
816
812
869
501
500
817
818

190

032
031
M0
M1

2G

12

02
G
C
D
A
B

E
F
-
110
120
130
140
100
1000
P1
P2
R

1F
MP

KG1
KG2

U1
V1
W1

U2
V2
W2

810
2001
1
2

2000
840
+

TO AUTOMATIC DOOR CONNECTIONS


BATTERY
YÜKSEK DÜŞÜK

1* Contactors must be of AC-3 class with 220VAC coils !


HIZ HIZ
ML60X VERSION : 2.1
TWO SPEED CONTROL PANEL CONNECTIONS
RC filters must connected across the coils of contactors ! MIKROLIFT DATE : 30.01.2010 WITH MLKS10 EMERGENCY RESCUE SYSTEM
2* These contacts must be the main contacts of RU1 and RU2 contactors !
( FOR SINGLE PHASE AUTOMATIC DOOR MOTOR )
MUHENDISLIK SCHEME NO : ML60X_03