2nd Term RC Questionaire

This document contains 8 questions related to the analysis and design of reinforced concrete structures. Question 1 asks to determine the required spacing of stirrups for a rectangular beam. Question 2 asks to calculate properties of a reinforced concrete column section including nominal axial strength, moment capacity, and factored moment. Question 3 asks to calculate the permissible load capacity of a short tied column given eccentricities. Question 4 asks to calculate nominal load capacities and required reinforcement for a spiral column given dimensions and material properties. Questions 5-8 ask to determine stirrup spacing, construct a column interaction diagram, and calculate long-term deflection given load and member information.

Uploaded by

Badjao Ako
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
141 views1 page

2nd Term RC Questionaire

This document contains 8 questions related to the analysis and design of reinforced concrete structures. Question 1 asks to determine the required spacing of stirrups for a rectangular beam. Question 2 asks to calculate properties of a reinforced concrete column section including nominal axial strength, moment capacity, and factored moment. Question 3 asks to calculate the permissible load capacity of a short tied column given eccentricities. Question 4 asks to calculate nominal load capacities and required reinforcement for a spiral column given dimensions and material properties. Questions 5-8 ask to determine stirrup spacing, construct a column interaction diagram, and calculate long-term deflection given load and member information.

Uploaded by

Badjao Ako
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 1

7) Locate the Geometric Centroid and Plastic Centroid

SECOND TERM EXAMINATION (REINFORCED CONCRETE) for the column section C6. consider fc’=21 MPa and
fy= 275MPa. Diameter of main reinforcement is
1) A rectangular beam has b=300mm and d=580mm.
25mm, ties are 10mm and concrete cover is 40mm
The beam is subjected to service dead load of
21kN/m and service dead load of 23kN/m over a
8) Determine the long term deflection for the simply
simple span of 6m. fc’=21MPa, fy=227MPa.
supported beam with section DT2 .having a span of
Determine the required spacing for 10mm
6 m loaded with uniformly varying load of 13kN/m
diameter stirrups for the critical point specified by
dead load and 25kN/m live load at one end and
the NSCP 2010/15.
zero at the other end. Assume 20% live load is
2) A 300mm x 400mm RC1 column is reinforced with
continuously applied for three years. fc’= 21MPa
3-32mmφ and 2-28mmφ vertical reinforcement
and fy= 414 MPa
placed as shown in RC5. If fc’= 21MPa and fy=
415MPa, calculate:
a) The nominal axial strength of the section at zero
eccentricity
b) The moment of the nominal axial strength
c) Factored moment resulting from a factored load
Pu= 1000kN.

3) Calculate the permissible load capacity Pn of the


short tied column shown in RC3 if ex= 200mm and
ey= 100mm use fc’= 27.6MPa and fy=414MPa.

4) The spiral column shown in figure C7 is reinforced


with eight 25mm diameter bars. Concrete cover
measured from the bar centroid is 60mm. fc’=
27.6MPa and fy= 414MPa. Calculate:
a) Nominal load Pn when e= 100mm
b) Nominal load Pn when e= 200mm
c) The required number of 25mm bars if Pn=
2800kN and Mn= 250kN.m

5) Determine the spacing of vertical stirrups near the


left support of the beam loaded as shown in figure
V3. Given the following data:
bw= 305mm PD=110kN
d= 490mm PL= 140kN
fc’= 25MPa WD= 30kN/m
fy= 275MPa WL= 34kN/m

6) The frame in the figure FR1 are subjected to


loading and responded as shown. All columns are
made of section show in C3. Construct the column
interaction diagram of column C3 and determine
which column will be safe and will fail. Use fc’=
21MPa and fy=275MPa.