Technical Data Sheet "Infinity 3100": 10 15 20 kVA 3Ph - 1Ph

This technical data sheet provides specifications for the Infinity 3100 UPS system in 10, 15, and 20 kVA versions. Key details include: - Nominal output power ratings of 10, 15, and 20 kVA at 0.8 power factor and 8, 12, and 16 kW at 1.0 power factor. - Efficiencies over 92% in online double conversion mode and over 98% in ECO mode. - Standard internal lead acid battery banks of 2 x 180 or 2 x 186 cells. - Rectifier/charger uses IGBT technology to minimize harmonics and allow for input voltage variations. - Modular design for high reliability and easy repair of individual

Uploaded by

Florin M
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
54 views7 pages

Technical Data Sheet "Infinity 3100": 10 15 20 kVA 3Ph - 1Ph

This technical data sheet provides specifications for the Infinity 3100 UPS system in 10, 15, and 20 kVA versions. Key details include: - Nominal output power ratings of 10, 15, and 20 kVA at 0.8 power factor and 8, 12, and 16 kW at 1.0 power factor. - Efficiencies over 92% in online double conversion mode and over 98% in ECO mode. - Standard internal lead acid battery banks of 2 x 180 or 2 x 186 cells. - Rectifier/charger uses IGBT technology to minimize harmonics and allow for input voltage variations. - Modular design for high reliability and easy repair of individual

Uploaded by

Florin M
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 7

TECHNICAL DATA SHEET “INFINITY 3100”

10 15 20 kVA 3Ph(in) – 1Ph(out)


GENERAL INFORMATION
POWER - kVA 10 15 20
UPS typology ON LINE – Double conversion
ACTIVE stand by-operation (Optional)
Nominal output power (Cos Ø 0,8) - kVA 10 15 20
Nominal output power (Cos Ø 1) - kW 8 12 16
Efficiency (AC ÷ AC) - % (ECO mode) >98 >98 >98
Efficiency (AC ÷ AC) - % (ON LINE Double conversion mode) >92 >92 >92
Heat dissipation at nominal load:
-W 695 1040 1390
-kcal/hour 598 894 1195
UPS ambient temperature - °C 0 ÷ 40
BATTERY ambient temperature - °C 0 ÷ +25
UPS storage temperature °C -10 ÷ +70
BATTERY storage temperature - °C -10 ÷ +60
Relative humidity (non condensing) <95%
Altitude < 1000 mt (Above See Level)
Power derating for altitude > 1000mt According to “IEC62040-3”
Ventilation FORCED
Requested cooling air volume - m3/h 500 500 600
Audible noise level (according EN 50091) < 52 db
Standard battery type lead acid 7,2 Ah -n° of cells 2 x180 2x180 2x180
Standard autonomy time at nominal load - min. 15 8 5
Storage time of battery without recharge (at 25°C) 3 months
Protection degree IP 20
EMC compatibility According to “EN50091-2”
(CE label)
Paint RAL 7016
Accessibility Front and top
Installation 10 cm from wall
Dimensions (mm) W = 450 D = 650 H = 1200
Weights (kg) (without battery - with battery) 90-250 100-260 100-260
2
Static load (kg/m ) (without battery - with battery) 310-854 340-890 340-890
Input/output cable connection Bottom / Rear Side
Movement By wheels
Ambient storage and transportation conditions According to “IEC62040-3”
Design standard According to “EN50091”
“IEC 62040”,“ISO 14001”
Free contact interface On request
Standard serial communication interface RS232

Rev. Descrizione / Description Data / Date Comp. / Comp. Contr. / Check. Appr. / Approv. Lingua / Pag. / di Pag. /
Lang. Pag. of Pag.
A First issue 28.04.05 F. Beoni E. Simoni E. Simoni E 1 7
B Update output current 09.11.05 P. Conti M. Mancini E. Simoni Cod. / Code
OM497007
BLOCK DIAGRAM

1. Input mains (separate for by-pass and rectifier)


2. Rectifier and battery charger
3. Standard internal battery
4. Optional external battery
5. Inverter
6. Emergency line (by-pass)
7. Inverter (SSI) and by-pass (SSB) static switch

DESCRIPTION:

 The UPS is designed following the criteria of low environmental impact.


 The quantity of the raw material used on the magnetic components and the number
of semiconductors is minimized by the means of very advanced design criteria.
 The high overall efficiency minimizes the power consumption.
 The ECO mode is available as a standard.
 The expected battery lifetime is maximized by the very advanced digital battery
charger.
 The UPS is designed in a full modular structure. Starting from a very high reliability
basis (by the mean of a preliminary test and burn in of each module) and a very low
time repairing time (the faulty module can be substituted in the field and repaired in
the factory).
 The UPS is equipped by a built in very advanced self diagnostic program indicating
the problems and suggesting to the service people how to repair the faults.
 Additional digital loops are included controlling:
◊ the DC components on the output voltage (Anti Saturation Loop “ASL”)
◊ the short circuit current (Soft Short Recovery Loop “SSRL”)
◊ the high crest factor load current (Current Boost Gain “CBG”)

OM497007 B 2
RECTIFIER and BATTERY CHARGER
POWER - kVA 10 15 20
Input configuration 3 Phase + Neutral
Nominal Input Voltage – Vac 230 (+10% -20%)
Input Frequency – Hz 50-60 +/- 5
Input Power Factor > 0.99
Harmonic current distortion rejected in to the mains < 4%
DC Output Voltage Accuracy +/- 1%
DC Output Voltage Ripple 2% rms
Battery Recharging Characteristic IU (DIN 41773)
Temperature Battery Voltage Compensation On Request
Maximum Recharging Current (at nom. load) - A 2x6 2x10 2x6
AC-DC converter type IGBT
Input protection Fuses
Inrush input current - A
Earth leakage current - mA
Nominal Current Absorbed from Mains - A 12 19 23
(At nominal load and Battery charged)
Maximum Current Absorbed from Mains - A 24 36 36
(@ nom. Load, maximum recharging current, Uin = -20%)

DESCRIPTION:

 The Input rectifier is designed to minimize the harmonics rejected into the input
mains.
 The technology is based on a full bridge 6-IGBT matrix, fully digitally controlled.
 Large input mains variations are allowed.
 The battery charger function is included on the same converter.
 The converter is designed to recharge the battery for long time autonomies.

OM497007 B 3
BATTERY
POWER - kVA 10 15 20
Type Without maintenance
Number of Cells 2 x 180 2 x 186
Floating Voltage at 25°C - Vdc 2 x 406 2 x 418
Minimum Discharge Voltage - Vdc 2 x 310 2 x 310
Typical recharging current C20
Power Requested by Inverter (at nominal Load) - kW 8,5 12,7 17
Curr. Req. by Inverter (nominal load –minimum Vdc) - A 12 18 24
Battery Protection Fuses
Battery Test Included as standard

DESCRIPTION:

 The battery is composed by two strings of 180 or 186 sealed lead cells.
 The recharging mode is constant current followed by constant voltage type (DIN
41773).
 The battery temperature compensation is available as an option.
 Long autonomy batteries can be assembled in an external cubicle.
 Several automatic and manual battery tests are available.

UPS OUTPUT: INVERTER

DESCRIPTION:

 The Inverter design is based on IGBT high frequency bridge, fully digitally
controlled.
 The output voltage stability and the dynamic response are optimized. Nested
voltage an current mode loops are implemented the DC components on the output
voltage is controlled by a separate loop (Anti Saturation Loop “ASL”).
 The output voltage total harmonic distortion is kept very low with both linear and not
linear (switching) load (Current Boost Gain “CBG”).
 The selectivity in case of short-circuit is very high and the recovery of the voltage is
digitally controlled (Soft Short Recovery Loop “SSRL”).
 The Inverter is designed to minimize the battery stress during the discharge.
 ECO mode available: load on by-pass and inverter on, the load transfer time is less
than 5 msec.

OM497007 B 4
INVERTER
POWER – kVA 10 15 20
Inverter Bridge IGBT (transformerless)
Nominal Output Power (Cos φ 0,8) 10 15 20
Nominal Output Power (Cos φ 1) 8 12 16
Permissible range of load power factor See Above
Nominal Output Voltage - Vac 220-230-240 (On request)
Output configuration Mono-phase
Output Voltage Stability
- Static +/- 1% rms
- Dynamic (Step Load 0÷100%÷0) +/- 2% rms
- Output Volt. Recovery Time (after step load) Within 10 msec
- IEC 62040-3 Classification 1
Output Frequency - Hz 50 - 60
Output Frequency Stability - Hz
- Internal Quartz Oscillator - Hz +/- 0,001
- Inverter Sync. with Mains - Hz +/- 2 (Other on request)
Nominal Output Current – A (@ 230 Vac output)
- PF φ 0,8 43 65 87
- PF φ 1 35 52 70
Overload Capability 125% for 10 min
200% for 100 msec
Short Circuit Current – A 70 104 140
Short Circuit Characteristic Elect. short circuit protection, current
limited at 2 times nominal current.
Automatic stop after 5 seconds
Selectivity Within ½ cicle (Fuse gl 20% In)
Output Waveform Sinusoidal
Output Harmonic Distortion
- Linear Load <2%
- Non Linear Load (Crest factor 3:1) <5%
- IEC 62040-3 Fully complayed
Crest Factor (Non linear load) 3:1

OM497007 B 5
UPS OUTPUT: BY PASS
Automatic Static By-Pass Electronic Thyristor Switch
Protection Fuses
Nominal Voltage - Vac 220-230-240 +/-10%
Nominal Frequency - Hz 50 - 60 +/-5Hz
Transfer mode Without interruption
Transfer Inverter ÷ Static By-Pass In case of :
-Static Switch test
-Inverter failure
-Input inv. Volt. out of limit
-Output Volt. out of limit
Retransfer Static By-Pass ÷ Inverter - Automatic
- Block on bypass after 6
commutations within 2 min.
- Reset by front panel or by
remote command
Overload Capability -200% Continously
-1000% For 1 Cicle
Manual By-Pass Standard:
- Electronically controlled
- No break
Back-feed protection Included as standard

DESCRIPTION:

 The back feed protection minimizes the danger caused by the inverter voltage feed
back in case of by-pass fault.
 The manual by-pass is included as a standard. The electronic control avoids the
risks of power interruption in case of transfer from inverter to manual by-pass and
vice-versa.

PARALLEL
Automatic Parallel Redundant Configuration Up to four by an additional card
Parallel Configuration Redundant N-1 on N
Connection Type CAN Bus Loop
Share Accuracy 10% max unbalancement
Maximum Distance Between two Units 100 mt
Overload Capability N x 200% Continuously
Automatic By-Pass On each unit
Manual By-Pass On each unit (common as
option)

DESCRIPTION:

 The parallel control is full digital and acts on both active and reactive power on each
output phase.
 The Loop connection permits to disconnect one of the units from the parallel string
allowing the normal operation of the remaining units.
 The can bus communication allows to connect the units by a DB9 standard
connector.
OM497007 B 6
ALARMS,CONTROLS AND SIGNALS
LOCAL ON THE “SYSTEM CONTROL PANEL” :
- Synoptic diagram showing : power flow, circuit breaker status and alarms
- Battery test indicator
- LCD display
- Keyboard

REMOTE ON PC (by the means of a special test software):


- All the local indications alarms and measures
- Battery test functions
- Basic troubleshooting

FREE CONTACTS (by the means of an additional card):


- Eight signals are available on free contacts.

REMOTE ON GPCC (general purpose communication card):


- All the local indications alarms and measures are available on the following
standards:
1. SNMP
2. MODBUS
3. GPRS/GSM Modem
4. WEB SERVER

OPTIONS
1. BATTERY TEMPERATURE VOLTAGE COMPENSATION
2. INSULATION TRANSFORMER
3. FREE CONTACTS CARD
4. GPCC CARD
5. PARALLEL CARD

OM497007 B 7

You might also like