Digix-1 PLC - Compact Series: Features
Digix-1 PLC - Compact Series: Features
Digix-1 PLC - Compact Series: Features
Features :
! Compact PLC with built in HMI
! 2 x 8 Character LCD
! Real Time Clock
! Windows based User Friendly Software for Ladder Programming &
HMI Configuration
! RS485 based Communication with MODBUS RTU Protocol
! Serial Printing
70 x 90 x 66.4mm
Display 2 x 8 Characters LCD (Green backlight) / Programming Method Windows based Software for Ladder
LED Indications for Inputs and Outputs Programming and HMI Configuration.
No. of Keys 5 Keys (4 - User configurable)* Memory Data Memory : 16 kB
Code Memory : 112 kB
EEPROM Memory : 1 kB
Input Specifications
Max. no. of Objects 2000 (As per Memory)
Digital Input
Minimum Scan Time 200 µSec
No. of Digital Inputs 8 Typical Scan Time 2 mSec (Based on Ladder Scan Time)
Input Type PNP
Input Voltage Range 5 - 30V DC
Response Time Typical 2 mSec (Based on Ladder scan time)
Environmental Specifications
& 100 µSec for Fast Input Operating Temperature 0 to 55ºC
Isolation No Storage Temperature -20 to 70ºC
Debounce Time 0 to 255 mSec (Default 10 mSec) Humidity (Non Condensing) 10% to 95% RH
Timer Accuracy 0.1% or 2 mSec (Whichever is greater)
Fast Input
Mechanical Specifications
No. of Channels 1
Frequency 5 KHz Mounting DIN Rail Mount
Weight Approx 240 gms.
Output Specifications
Functional Features
Digital Output - Relay
Timer Operational Modes On Delay, Off Delay, Pulse,
Digital Outputs 5 (NO type with 2 COM Points) Special [Up/Down] Timer, 1 ms timer
Contact Rating 5A @ 240V AC (Resistive) Timer Resolution 1 mSec (Accurate only for 1 mSec Timer block)
5A @ 28V DC (Resistive)
Counter Up Counter, Down Counter,
Isolation No Up/Down Counter, Special [Up/Down] Counter
Response Time 20 msec Other Blocks Analog Input, FTC, PIDT, Rampsoak
Mechanical Life 30000 Cycles Memory Retention 10 years (1kB)
RTC Yes (Available In DIGIX-1-1-1-230V)
Communication Clock Drift Max 4 sec/day
*Usage limited to only 4 Nos
Communication Port RS485 [Slave]
RS485 [Master]
Communication Protocol MODBUS RTU Auxiliary Supply Specification
Connector RJ25 (Slave)
Supply Voltage 90 to 270V AC 50/60 Hz., 18 to 30V DC
Screw terminal (Master)
Power Consumption 6W Max
Supported Expansion* EXP FLEX 2M
Source 10V, 50mA in AC Model Only
Transmission Mode Half Duplex
VAR IN_OUT & VAR OUTPUT types Variables Maximum Retention 25 variables only each of 32 bit @ 110V, @ 24VDC
Transmission Speed 9600, 19200, 38400, 57600, 115200 bps
Parity None, Odd, Even, Mark, Space
Data Bits 7 or 8
Stop Bits 1 or 2
Settable Slave 1 - 255
*Expansion is supported only on PLC having Master Communication
www.selec.com 1
DIGIX-1 PLC - Compact Series
44 DIGIX-1-0-0-24VDC / DIGIX-1-0-0-24VDC-B
70
90
45
B
62
Terminal Connections
+24VDC
Port Description
Pin Description
1 RS485 + ve
2 NC
3 NC
4 NC
5 NC
6 RS485 - ve
www.selec.com 2