The filter switch position identifies when a filter is installed. When a new filter is
installed, the change in switch position resets the software counter.
Switch is open when filter is installed. Switch is closed with filter removed.
4 Tabs
Whirlpool Confidential 13
Reservoir Cover
Whirlpool Confidential 14
Frenchdoor Dual Evaporator Water Flow Schematic
Whirlpool Confidential 20
Removing the Ice Maker Assembly – Cont
Whirlpool Confidential 21
Accessing the Ice Maker and Fan Motor
Fill - 49 ML
10 Tablespoons
Whirlpool Confidential 25
Accessing Water Reservoir and Valves
Drop the front of the housing and disengage the 3 rear tabs from the
three slots in the top of the refrigerator cabinet.
Reservoir
Dual Water
Filter Head
Valve
Filter Switch
Reservoir
1100 ML /37 OZ.
Disconnect ¼” reservoir
water tube from dual valve
Disconnect wires
Whirlpool Confidential 36
Removing RC Evaporator Cover
RC Evaporator
Deli Air Fan motor RC Evaporator
Damper Thermistor
Insert a wide straight blade between the A loud snap may be heard when the
cap and the rail approximately 1” from tabs release.
the bottom of the cap and twist. Repeat Repeat process on the opposite side
at the top of the cap if necessary
AK12 36 IN. DUAL EVAPAPORATOR FRENCH DOOR Whirlpool Confidential 39
Accessing Deli User Interface Control Board
Deli Thermistor
45
Machine Compartment
Condenser
3 Way Valve Fan
Drier
Drain Tube
Compressor
Smart
Valve
Inverter
Mufflers Evaporation
Check Valve Pan
Refrigerant to
Evaporator
Refrigerant to
Evaporator
Refrigerant
from Drier
59
60
61
Voltage Measurement Safety Information
When performing live voltage measurements, you must do the following:
Verify the controls are in the off position so that the appliance does not start when energized.
Allow enough space to perform the voltage measurements without obstructions.
Keep other people a safe distance away from the appliance to prevent personal injury.
Always use the proper testing equipment.
After voltage measurements, always disconnect power before servicing.
62
Power Supply Board
P1
P2
1
P1 115VAC
P1-3 P1-4 Constant 115 VAC
P2-1 P2-4 Constant 14VDC
P2 P2-2 P2-5 14VDC Constant 14VDC
P2-3 P2-6 Constant 14VDC
P13
P9
1
1
P14 P6 P4
P5 P7
P8
1 1
1
1 1
1
P13-1 P13-2 3way refrigerant valve, Cannot check voltage output
P13
P13 P13-3 P13-4 3way refrigerant valve, Cannot check voltage output
P9 P14-1 P14-2 FC Fan Motor Output. Activate Service Test 3, step 2
14
P-14 P14-3 P14-4 RC Fan Motor Output. Activate Service Test 3, step 3
1 VDC
1 P14-7 P14-6 Constant 14VDC
P14 14
P9 P9-2 P9-3
P8 VDC Icebox fan output. Test 36. SW3 to activate. 01=14VDC
1
P8-1 P8-2 Ice Bin Thermistor output = 1.5-5.0 VDC
5VDC
P8 P8-3 P8-4 RC Evap. thermistor output = 1.5-5.0 VDC
P8-7 P8-8 3-6VDC Inverter output 3-6 VDC Constant
P6 P4
P5 P7
1 1
1 1
120 VAC