Online Double-Conversion Topology Wide Input Voltage Range

This topology guarantees consistently high power quality by regenerating any power disturbances through AC to DC and back to AC conversion, using the battery only for serious incidents. It has a wide input voltage range of 120-300V and automatically transfers the load to utility power in an overload or fault. It can monitor and control UPS solutions through an optional SNMP card or remote software, alerting users and automatically shutting down servers during power events. It has a high-performance battery charger and can start applications on battery power during outages, offering 5-8 minutes of backup at full load or external batteries for hours of runtime.

Uploaded by

tonielhage
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
24 views1 page

Online Double-Conversion Topology Wide Input Voltage Range

This topology guarantees consistently high power quality by regenerating any power disturbances through AC to DC and back to AC conversion, using the battery only for serious incidents. It has a wide input voltage range of 120-300V and automatically transfers the load to utility power in an overload or fault. It can monitor and control UPS solutions through an optional SNMP card or remote software, alerting users and automatically shutting down servers during power events. It has a high-performance battery charger and can start applications on battery power during outages, offering 5-8 minutes of backup at full load or external batteries for hours of runtime.

Uploaded by

tonielhage
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 1

Internal Automatic Bypass

Utility Filtering Load


AC to DC DC to AC
Rectifier Inverter Input voltage Output voltage

Battery

Online double-conversion topology Wide input voltage range


This topology guarantees a consistently high level of power quality. DX UPS have a very wide input voltage range of up to 120-300V,
Any disturbances on the distribution waveform are regenerated via optimized to improve compatibility with engine generator sets and
the AC to DC then DC to AC conversion process. The battery is used reduce the numbers of transfer to battery power. The batteries are
only as a backup source. used only for the most serious incidents, maximizing available back-
up time and extending battery life.
High performance and reliability
DX uses High Frequency technology to bring its users a compact. Automatic bypass
UPS that delivers perfect sine wave output.
In case of overload or UPS fault, the DX UPS automatically transfers
the load to utility AC power.

Advanced communications
An RS232 port is available for easy connection of the UPS to the
server. It may be used for local monitoring. An optional SNMP card
is also available for network administration.

WINPOWER monitoring software can be used to:

s Alert users of a power event or pre-specified condition

s Automatically shut down your servers

s Remotely supervise and control UPS solutions

High-performance battery charger Cold start-on-battery power


The DX battery charger: This function ensures trouble-free start-up of your applications even
during a utility power outage.
s Reduces battery recharge time
Backup times from five minutes to several hours
s Protects the battery against damage caused by deep discharge
DX UPS offers a standard backup time of five to eight minutes on
s Prevents disturbances on the distribution system by correcting the full load to protect the applications. XL models allow users to reach
power factor several hours of runtime using external batteries.

s Avoids propagating faults on the distribution system (back-feed


protection)

E SERIES DX BATTERY RUNTIME CHART


LV Model 1000 1500 3000 6000 10000 1:1 10000 3:1 15000 3:1 20000 3:1
Battery Runtime 1/2 load 14min 14min 17.5min 23min 12min External bat External bat External bat
Battery Runtime Full load 5min 5min 5min 8min 5min External bat External bat External bat
HV Model 1000 2000 3000 6000 10000 1:1 10000 3:1 15000 3:1 20000 3:1
Battery Runtime 1/2 load 14min 31min 16min 20min 16min External bat External bat External bat
Battery Runtime Full load 7min 11min >5min 8min >5min External bat External bat External bat