Installation Manual
COLOR SCANNING SONAR
FSV-30/FSV-30S

SAFETY INSTRUCTIONS................................................................................................i

SYSTEM CONFIGURATION..........................................................................................iii

EQUIPMENT LISTS ....................................................................................................... iv

1. MOUNTING THE EQUIPMENT................................................................................1-1


1.1 Hull Unit ................................................................................................................................1-1
1.2 Processor Unit ......................................................................................................................1-8
1.3 Control Unit...........................................................................................................................1-9
1.4 Transceiver Unit ..................................................................................................................1-12
1.5 Grounding the Equipment ...................................................................................................1-12
1.6 Installing the Attachment Flange (option)............................................................................1-13
1.7 Cable Extension Kit (option) ...............................................................................................1-14
1.8 Installing the Attachment Kit (option)...................................................................................1-15

2. WIRING ....................................................................................................................2-1
2.1 How to Use the Crimping Tool, Pin Extractor ........................................................................2-1
2.2 Wiring....................................................................................................................................2-2
2.3 Processor Unit .................................................................................................................... 2-4
2.4 Transceiver Unit ..................................................................................................................2-10
2.5 Cable Extension Kit ............................................................................................................2-14
2.6 Input Voltage and Fuses .....................................................................................................2-18

3. ADJUSTMENT AND CHECK ...................................................................................3-1


3.1 Hull Unit Check .....................................................................................................................3-1
3.2 Heading Adjustment..............................................................................................................3-5
3.3 Configuring Own Ship Mark ..................................................................................................3-7
3.4 Other SYSTEM Menu Items .................................................................................................3-9
3.5 CONE Board Setting in the Processor Unit.........................................................................3-13
3.6 DIP Switch Setting ............................................................................................................3-14

4. CONNECTING THE EXTERNAL INTERFACE CS-120A ........................................4-1


PACKING LISTS ......................................................................................................... A-1
OUTLINE DRAWINGS ................................................................................................ D-1
INTERCONNECTION DIAGRAMS ............................................................................. S-1

www.furuno.co.jp
The paper used in this manual
is elemental chlorine free.

・FURUNO Authorized Distributor/Dealer

9-52 Ashihara-cho,
Nishinomiya, 662-8580, JAPAN

Telephone : +81-(0)798-65-2111
Fax : +81-(0)798-65-4200

All rights reserved. Printed in Japan A : DEC . 2003


F : DEC . 13, 2010
Pub. No. IME-13230-F
(TATA ) FSV-30/30S *00014857415*
*00014857415*
* 0 0 0 1 4 8 5 7 4 1 5 *
SAFETY INSTRUCTIONS

DANGER WARNING
Keep away from moving Install the specified transducer tank
shaft of the hull unit. in accordance with the installation
instructions. If a different tank is to be
Gears may cause injury. installed the shipyard is solely respon-
sible for its installation, and it should
be installed so the hull will not be
damaged if the tank strikes an object.

The tank or hull may be damaged if the


tank strikes an object.
WARNING
Do not open the cover If a steel tank is installed on a wooden
unless totally familiar with or FRP vessel, take appropriate
electrical circuits and measures to prevent electrolytic
service manual. corrosion.

High voltage exists inside the Electrolytic corrosion can damage the
equipment, and a residual hull.
charge remains in capacitors
several minutes after the Be sure that the power supply is
power is turned off. Improper compatible with the voltage rating of
handling can result in electri- the equipment.
cal shock.
Connection of an incorrect power supply
Turn off the power at the switchboard can cause fire or damage the equipment.
before beginning the installation.

Fire or electrical shock can result if the


power is left on.
CAUTION
Do not install the equipment where it Ground the equipment to
may get wet from rain or water splash. prevent electrical shock and
mutual interference.
Water can cause fire or electrical shock, or
damage the equipment.

Be sure no water leaks in at the trans-


ducer installation site.

Water leakage can sink the vessel. Also


confirm that the transducer will not loosen
by ship's vibration. The installer of the
equipment is solely responsible for the
proper installation of the equipment.
FURUNO will assume no responsibility for
any damage associated with improper
installation.

i
CAUTION
Maximum speed while the transducer is
projected or being raised or lowered
is as below, to prevent damage to the
transducer.

Projected Raising/
Lowering

1200 mm stroke Max. 18 kt Max. 15 kt

1600 mm stroke Max. 15 kt Max. 12 kt

Observe the following compass safe


distances to prevent interference to a
magnetic compass:

Standard Steering
compass compass

Processor Unit 1.55 m 1.05 m

Control Unit 0.20 m 0.15 m

Other equipment should be positioned at


least 7 m away from a magnetic compass.

ii
SYSTEM CONFIGURATION

VGA Monitor

CONTROL UNIT
FSV-3001

AD Converter Gyrocompass
AD-10

Loudspeaker
Current
Indicator
Sub Monitor

Current
Echo Sounder, Indicator/Log
Current Indicator,
other
E/S Interface
PROCESSOR UNIT VI-1100A
Navigator 1
FSV-3002/3002S
Net Recorder
Navigator 2
VI-1100A

External Net Sonde VI-1100A


Interface CS-120A Junction Box
(Note 1) CS-170 Net Sonde

220 VAC,
100/110/115/ Cable for 3φ, 50/60 Hz
220/230 VAC, Extension Kit
1φ, 50/60 Hz FSV-305-5 or HULL UNIT
FSV-305-15
(incl. Junction Hull unit Specifications
Box)
TRANSCEIVER FSV-303
1200 mm stroke
UNIT FSV-303-R
FSV-301 FSV-304
FSV-304-R 1600 mm stroke

100/110/115/
220/230 VAC,
Standard
1φ, 50/60 Hz
Local Supply
Note 1: Power Kit FSV-2403 (option, installed in Option
processor unit) required to connect CS-120A.

iii
EQUIPMENT LISTS
Standard supply
Name Type Code No. Qty Remarks
Control Unit FSV-3001 — 1 With cable
FSV-3002 — For FSV-30
Processor Unit 1
FSV-3002S — For FSV-30S
Transceiver Unit FSV-301 — 1
FSV-303/303-R — 1200 mm stroke
Hull Unit 1
FSV-304/304-R — 1600 mm stroke
Signal cable 10S2078
CP10-06000 000-144-389 1 set (between transceiver unit and
hull unit, 8 m)
For transceiver unit. See
Installation Materials CP10-06201 007-008-540 1 set
packing list.
1 set For processor unit
CP10-06100 000-067-067 CP10-04502, CP10-04506.
See packing list.
For transceiver unit. See
SP10-03101 007-008-530 1 set
packing list.
Spare Parts For processor unit. See
SP10-02601 006-921-340 1 set
packing list.
SP10-02603 006-921-360 1 set For processor unit
FP10-02901 007-008-780 1 set For processor unit
Accessories
FP10-02201 006-922-390 1 set For control unit

Optional Equipment
Name Type Code No. Qty Remarks
Control Unit FSV-3001 — 1
37-core Cable 10S1258 001-113-000-10 1 Specify length
E/S Interface VI-1100A — 1
Net Sonde CS-170 — 1
Junction Box
Power Supply Kit FSV-2403 000-067-013 1 For connection of CS-120A
NMEA Cable MJ-A6SPF0012-100C 000-154-037-10 1 10 m, NMEA, 6P-6P
MJ-A6SPF0012-050C 000-154-053-10 1 5 m, NMEA, 6P-6P
8-core Cable VVS 0.3×8C *6M* 000-555-043 1 6 m, for echosounder, 02S8040
Attachment
OP10-27 000-067-050 1
Flange
Attachment Kit OP10-24 006-943-530
Loudspeaker SEM-21Q 000-144-917 1
Installation See back of manual for details.
CP10-04801 006-934-240 1
Materials
Cable Extension FSV-305-5 000-067-072 Junction box, 10S2240, 10S2144
Kit 1
FSV-305-15 000-067-073 Junction box, 10S2240, 10S2145
Data Recording
OP10-31 000-017-095 1
Kit
Calibration Ball OP10-33 000-017-096 1 φ38.1
OP10-34 000-017-097 1 φ47.625

iv
1. MOUNTING THE EQUIPMENT

NOTICE
Do not apply paint, anti-corrosive sealant
or contact spray to coating or plastic
parts of the equipment.

Those items contain organic solvents that


can damage coating and plastic parts,
especially plastic connectors.

1.1 Hull Unit


Note 1: The raise/lower control box on the hull unit contains a motion sensor. Therefore,
never drop the hull unit.
Note 2: Handle the transducer carefully. Shock will damage its sensitive components.

1.1.1 Mounting considerations


Decide the location of the hull unit through consultation with the dockyard and ship owner.
When deciding the location, the following points should be taken into account.

• Choose an area where propeller noise, cruising noise, air bubbles and interference from
turbulence are at a minimum. Generally, the point at 1/3 to 1/2 of the ship’s length from
the bow on or near the keel is optimum. On-the-keel installation is advantageous for
minimizing oil consumption in comparison with off-the-keel. If the hull unit can not be
installed on the keel, the center of the retraction tank should be within 600 mm of the keel
to prevent a rolling effect. For large ship with deep draft, the hull unit can be installed at
the bow.

1/2 1/3
Within 600 meter
Hull unit mounting location
• Choose a place where the hull bottom is flat and the draft is sufficiently deep. Normally,
the transducer should protrude at least 500 mm beyond the keel to minimize the effect of
air foam and bubbles.
• Choose a place where interference from other transducers is minimal. The hull unit
should be at least 2.5 m away from the transducers of other equipment.

1-1
• No obstacle should be in the fore direction since it causes a shadow zone and aerated
water, resulting in poor sonar performance.
• The physical distance between the hull unit and the transceiver unit should be no more
than 5 m.
• The space shown in the figure on the next page is required around the hull unit for wiring
and maintenance.
• If the ambient temperature around the unit will be below 0°C, provide the sonar
compartment with a heater to keep the temperature above 0°C.
1300 650
650
650

Maintenance space, example sonar compartment


Note: After mounting the equipment, install anti-vibration stays, referring to page 1-7.

1-2
1.1.2 Shortening the retraction tank
The retraction tank is 1300 mm in length when supplied. Shorten the tank as necessary so
that the transducer positions well below the keel when it is fully lowered. The following table
provides guidelines for shortening the tank. Refer also to the retraction tank installation
drawing at the back of this manual.

Installation
Method
D D
XDCR Travel

Remove 280 Remove 280 - 290 mm


- 290 mm from the bottom.
from the Same as left.
1200 mm Same as left. Note that the length
bottom. "D" must be less than
stroke
1170 mm.

Remove Remove less than


less than 290 mm from the
290 mm bottom. Note that the Same as left.
1600 mm Same as left.
from the length "D" must be less
stroke
bottom. than 1570 mm.

Guidelines for shortening the retraction tank


Note 1: For the 1200 mm stroke hull unit, the transducer will not fully protrude unless the
tank is shortened by at least 280 mm from the bottom, and cannot be fully retracted
if more than 290 mm is removed.
Note 2: For the 1600 mm stroke hull unit, the transducer cannot be fully retracted if the tank
is removed more than 290 mm.
Note 3: When 290 mm is removed and “D” is minimum, the effect of air foam is minimized
because the transducer fully protrudes in water.

1-3
1.1.3 Remarks for installation of retraction tank
1. Make, if possible, the installation location a double bottom structure.
2. Install, if possible, the tank on the keel where the tank can be most firmly fixed.
3. Install the reinforcement ribs as near as possible to the top of the retraction tank,
allowing space for tightening of nuts and bolts.
Retraction tank Reinforcement rib

250-300 mm

How to install reinforcement ribs


4. Add a doubling plate (a plate added to another to give extra strength or stiffness) at the
location where the retraction tank is welded to the hull bottom. The size of the doubling
plate is normally 1300 mm in diameter so that it may lie across two bottom frames.
5. Use a chisel to inscribe the bow mark on the attachment flange.

1-4
1.1.4 Installing hull unit on retraction tank
After welding the retraction tank and allowing sufficient time for cooling, install the hull unit
as follows:

1. Clean the hull unit flange, the O-ring and O-ring groove. Coat them with a slight amount
of grease. Place the O-ring in position on the tank flange.

2. Orient the hull unit so that the bow mark (inscribed) on its flange points toward the ship’s
bow. Note that heading adjustment is required if the bow mark is not facing the ship’s
bow.

3. Confirm that the O-ring is in position. Place the hull unit on the tank.

4. Coat every washer, nut and bolt with a slight amount of grease to ease removal. Fasten
the hull unit to the retraction tank with flat washers, spring washers and hex bolts.

5. Reinforce the hull unit against vibration by extending stays to the ship’s hull from the two
eye bolts at the top of the hull unit, referring to the procedure on page 1-7.

1-5
Hex. Nut
Spring Washer
Flat Washer

Bow Mark
Hull Unit Flange

O-ring

Tank Flange

Flat Washer

Hex. Bolt

Hex. Nut

Spring Washer

O-ring
Flat Washer

O-ring

Retraction Tank

Flat Washer

Hex. Bolt
Hex. Nut
Spring Washer

Stern side (seven locations) Bow side (17 locations)

Installation of hull unit

1-6
1.1.5 Installing stays (anti-vibration measure)
Install stays from the top of the hull unit to the ship’s hull. The stays should be angle iron
with a size of 75×75×9 mm or more and at least two pieces should be used; one each to
ship’s bow and stern directions. Install if possible, two more stays in ship’s transverse
direction. This measure must be done to prevent damage to the transducer.

Bow

Stay

Stay

Hull Unit
Proper installation of stays
Do not install the stays on a crossbeam on an overhead. Vibration-resistance effect is
reduced since vibration is applied to the stays as rotation force. Install them horizontally.

Crossbeam
on overhead
Stay (WRONG installation method)

Eye Bolt
PROPER installation

Hull Unit 90

Proper and improper stay installation methods

1-7
1.2 Processor Unit
Mounting considerations
When choosing a mounting location, keep in mind the following points:

• The processor unit must be mounted upright.


• Locate the unit out of direct sunlight and away from heat sources because of heat that
can build up inside the cabinet.
• Do not locate the equipment where it may be subjected to water splash or rain.
• Be sure the mounting location is strong enough to support the weight of the unit under the
continued vibration which is normally experienced on the ship. If necessary reinforce the
mounting location.
• Determine the mounting location considering the length of the cables below.
● Signal cable from the transceiver unit
● Control cable from the control unit (when locally supplied monitor is used)
• Leave sufficient space on the sides and rear of the unit to facilitate maintenance. Also,
leave a foot or so of "service loop" in cables behind the unit so it can be pulled forward for
servicing or easy removal of connectors.
• Make free space of 400 mm between the processor unit and bulkhead to prevent cable
stress.
• Observe the compass safe distances shown on page ii to prevent interference to a
magnetic compass.

Cable fixing hole

Processor unit, rear view

1-8
Mounting procedure
1. Unfasten two bolts from the bottom of the front side of the processor unit. Pull the unit
toward you to separate it from the mounting base.
2. Use six bolts (M6×20, supplied as installation material) to fix the mounting base.
3. Place the processor unit in front of the mounting base.
4. Push the unit forward until it touches the end of the mounting base.
5. Refasten two bolts removed at step 1 to fix the unit to the mounting base.

504
5.5 477

160+1
34 8
200+1 195+1
Front view Top view
Processor unit

1.3 Control Unit


The control unit may be mounted on a tabletop with or without the KB (keyboard) fixing
plate (supplied), which mounts the control unit at an angle. If the control unit is not to be
fixed permanently, lay it atop the rubber feet (supplied as accessories). Be sure to observe
the compass safe distances noted on page ii to prevent interference to a magnetic
compass.

(1) Rubber feet


Attach four rubber feet to the bottom of the control unit if it is not going to be permanently
fixed.

1-9
(2) Mounting without KB fixing plate
1. Drill four mounting holes of 6 mm diameter to fasten the control unit, referring to the
outline drawing at the back of this manual.
2. Referring to the outline drawing for the control unit at the back of this manual, make a
cutout in the mounting location large enough to accommodate the name plate so the
control unit will lie flat.
3. Fix the control unit with four bolts (M5) from under the tabletop. (M5 bolts with a
sufficient length for the thickness of the tabletop should be provided locally.)
467±1

Fixing hole φ6

75 ±1 22
FSV-30

Control unit

(3) Mounting with KB fixing plate


1. To fix the control unit to a desired location at an angle, fasten the KB fixing plate to the
control unit and desired location with two upset screws (M5×10, supplied) and two
tapping screws (φ6.5, local supply) as below.

Upset screw (M5x10)


FSV-30

Tapping screw
( 6.5)

KB fixing plate
How to attach KB fixing plate
2. Set dust cover (supplied) to the control unit.

1-10
Passing the cable through the bottom of the control unit (for permanent mounting)
For permanent mounting methods (2) and (3), the control cable can be passed through the
bottom of the control unit as follows:

1. Unfasten eight screws (M4) to remove the cover from the bottom of the control unit.
2. Unscrew two screws (M4×10) to remove the cable clamp.
3. Disconnect two connectors J1 and J2 from the circuit board.
4. Attach the control cable to the control unit cover with the cable clamp (removed at step
2), two flat head screws (M4), flat washers, spring washers and nuts (hardware:
supplied).

Screw
M4x8 (8 pcs.)

Co
ntr
ol
un
it c
ov
er
Nut Previous cable hole
Clamp Spring washer
Flat washer
Screw (M4x12)
Fasten the cable with the clamp here.

Control unit, cover removed


5. Re-connect two connectors disconnected at step 3.
6. Fasten eight screws to attach the control unit cover.
7. Attach the connector seal (supplied) to the hole at the rear of the control unit.
8. Drill a hole of 30 mm in diameter to pass the cable from the bottom of the control unit
through the tabletop
9. Attach the connector seal (supplied) to the hole at the bottom of the control unit when
the above modification is not done.
10. Fix the control unit referring to (2) or (3) on the previous page.

Cable Cable

Without KB fixing plate With KB fixing plate


Control unit, side view

1-11
1.4 Transceiver Unit
The physical distance between the hull unit and the transceiver unit should be no more than
5 m. The transceiver unit should be mounted on a mounting base (shipyard supply) whose
dimensions are as shown in the outline drawing of the transceiver unit at the back of this
manual. Reinforce the transceiver unit against vibration by stays extending from the
eyebolts on the top of the unit. Fasten four bolts (M12, local supply) at the bottom of the
transceiver unit to fix the unit to the mounting location.

CHARGE

BV ERR

OV ERR

FUSE

Transceiver unit

1.5 Grounding the Equipment


Transceiver unit, junction box: Use copper strap (supplied).
Processor unit: Use a ground wire (IV-8SQ).
Junction box for hull unit: Use the wing bolt on the junction box.

1-12
1.6 Installing the Attachment Flange (option)
The attachment flange permits use of the tank for the CSH-20 series using the 1200 mm
stroke transducer.

Attachment flange Type: OP10-27, Code no: 000-067-050)


Name Type Code No. Qty Remarks
Attachment flange 10-077-5802 100-303-610 1
O-ring CO 0318A (V585) 000-166-370-10 1
Hex. nut M20 SUS304 000-863-116 48
Flat washer M20 SUS304 000-864-136 24
Spring washer M20 SUS304 000-864-270 24

Procedure
1. Clean the hull unit flange, O-ring and O-ring groove. Coat them with a slight amount of
grease.
2. Use 48 hex. nuts, flat washers and spring washers to fasten the attachment flange to
retraction tank.
3. Place the O-ring in position on the attachment flange.

To install the attachment flange and the hull unit, see paragraph 1.1.4.

Hex. Bolt

Flat Washer

Hull Unit Flange

O-ring

Flat Washer
Spring Washer

Hex. Nut

Attachment Flange
O-ring
Existing Tank
Flat Washer
Spring Washer
Hex. Nut

Attachment flange for 1200 mm stroke transducer, sectional view

1-13
1.7 Cable Extension Kit (option)
For extension of the transducer cable between the hull unit and the transceiver unit, use the
cable extension kit (option), which includes a junction box. The kit is available in 5 m or 15
m extension lengths. Below are the contents of each kit.

Name: Cable Extension Kit, Type: FSV-305-5, Code No.: 000-067-072


Name Type Code No. Qty Remarks
Junction box FSV-305 000-067-032 1
10S2240 000-148-369-03 1 5m
Cable assembly
10S2144 000-145-360 1 12.9 m

Name: Cable Extension Kit, Type: FSV-305-15, Code No.: 000-067-073


Name Type Code No. Qty Remarks
Junction box FSV-305 000-067-032 1
10S2240 000-148-370-03 1 15 m
Cable assembly
10S2145 000-145-361 1 22.9 m

Fasten the junction box to a bulkhead with 4 bolts (M6, local supply).

Junction box

1-14
1.8 Installing the Attachment Kit (option)
The attachment kit permits use of the tank for the CSH-20 series using the 1600 mm stroke
transducer and FSV-243E/244E.

Attachment kit (Type: OP10-24, Code no.: 006-943-530)


Name Type Code No. Qty
Insulation gasket (1) MS-1000-67 000-857-220 24
Insulation gasket (2) MS-1000-68 000-857-221 24

1. Clean the hull unit flange, the O-ring and O-ring groove. Coat them with a slight amount
of grease. Place the O-ring in position on the tank flange.

2. Lay the insulation gasket (1) on the top of the tank flange.

3. Orient the hull unit so that the bow mark (inscribed) on its flange points toward the ship’s
bow. Note that heading adjustment in the monitor is required if the bow mark does not
face the ship’s bow.

4. Confirm that the O-ring and the insulation gasket (1) are in position.

5. Place the hull unit on the tank.

6. Seven of the 24 bolt holes on the hull unit flange have already been fitted with bolts
(stern side). Insert the insulation gasket (2) into the bolt holes of the tank flange to which
these seven bolts are fitted.

7. Coat every bolt, washer and nut with a slight amount of grease to ease removal. Fit the
insulation gasket (2) into the bolt holes of the tank flange. Fasten the hull unit to the
retraction tank with insulation gasket (2), flat washers, spring washers and hex bolts.

8. Reinforce the hull unit against vibration by extending stays to the ship’s hull from the two
eye bolts at the top of the hull unit, referring to the figure at the top of page 1-8.

1-15
Hex. nut

Spring washer
Flange of hull unit Flat washer
Flange of hull unit

O-ring O-ring

Insulation gasket (1)


Insulation gasket (1)
Insulation gasket (2)
Insulation gasket (2)
Flat washer
Flat washer
Spring washer
Hex. nut Hex. bolt

Spring washer

O-ring
Flat washer
O-ring

Insulation gasket
Retraction tank
Insulation gasket (2)

Flat washer

Hex. bolt
Hex. nut
Spring washer

Stern side Bow side


(Seven locations) (17 locations)

Installation of attachment kit

1-16
2. WIRING
2.1 How to Use the Crimping Tool, Pin Extractor
A special crimping tool is necessary for connection of wires to the contact pins of the 38P
connector. The pin extractor removes the contact pin from the connector body. This
paragraph describes how to crimp and extract the contact pin.

Crimping Tool Contact Pin Pin Extractor


06-1001-016 60-8017-0313-00-339 06-1877-04
(000-519-542) (000-519-595)

Crimping tool, contact pin, pin extractor

2.1.1 How to use the crimping tool


1. Remove the vinyl sheath by 3 to 4 mm to expose
the core.
2. Hold the crimping tool horizontally and insert the
contact pin with its slit facing downward into the
crimp hole on the crimping tool.
3. Insert the wire onto the contact pin and squeeze
the handle until the rachet releases. (The wire
should be placed deep enough into the contact pin
so that its end comes in contact with the stopper
plate of the crimping tool.) With crimping
completed, pull the wire while holding the contact
pin to make sure that it is tightly fastened.

2.1.2 How to use the pin extractor


If a contact pin is inserted into an incorrect hole on
the connector body, remove it with the pin extractor.

1. Push the pin extractor into the pin hole from the
side opposite to the pin inserting side.
2. Push in the head of the pin extractor. The retaining
spring comes free and the contact pin can be 2
1
removed.

2-1
2.2 Wiring
10S2077 (10 m)

FSV-30

CONTROL UNIT FSV-3001

Monitor
Transceiver (Local supply)
unit

Control unit
Monitor cable
(Local supply)
Control unit
External
monitor
*1: If connector may loosen by
vibration monitor cable may also
*1
10S1258-1

Processor unit clamp be connected inside.

PROCESSOR UNIT
DPYCY-1.5 *2 FSV-3002/3002S

100/110/115/
TRANSCEIVER UNIT 220/230 VAC
FSV-301 1φ, 50/60 Hz

10S2078 (8 m) *3
*4 *5

220 VAC
100/110/115/ 3φ, 50/60 Hz
DPYCYS-2.5 *2 220/230 VAC
1φ, 50/60 Hz TPYCY-4 *2
HULL UNIT
FSV-303
(1200 mm stroke)
FSV-304
(1600 mm stroke)

10S2223 (14.6 m)
*4 *5
*2: Japan Industrial Standard cable
*3: The same type of connector is fitted at each end, however the connector where the amount of sheath
removed is greater should be connected to the transceiver unit.
*4: When running the cables of 10S2078, 10S2223 refer to next page.
*5: When using cable for extension kit, the length of the cable between the transceiver unit
and the hull unit is 5 m or 10 m.
Wiring

2-2
Transceiver unit side

P2
(40 pin)
0.38 m

P1
(34 pin) 0.07 m Clamp point
0.6 m

Clamp point.

10S2223
14.6 m

14.0 m
7.2 m

Hull unit side 10S2078


8m

Clamp point
0.07 m

0.28 m

Raise/lower control box


of the hull unit side

Note that the amount of cable inside the cable clamp on the cable between the hull unit and
transceiver unit may be shorted depending on cable length.

2-3
2.3 Processor Unit
Cables (10S2074, 10S1258-1 and control cable) from the various units are connected to the
CONE Board (10P6905) in the processor unit.

NOTICE
Divide cables attached to the back of the
processor unit between right and left side.
Tie each group with a cable tie at the
position 15 cm from connectors.

This is necessary to prevent cable stress.

15 cm

Cable tie
Processor unit, rear view

2.3.1 10S1258-1 cable


This cable runs between the processor unit and transceiver unit.
Shield
Anticorrosive Sheath

1. BLK 9. BLK/GRY 17. BRN/GRY


19 8 9 2. BLK/BRN 10. BLK/WHT 18. BRN/WHT
10 3. BLK/RED 11. BRN/RED 19. RED/ORG
18 7 2 3 11 4. BLK/ORG 12. BRN/ORG
1 4 5. BLK/YEL 13. BRN/YEL
17 6 12 6. BLK/GRN 14. BRN/GRN
5 7. BLK/BLU 15. BRN/BLU
16 13
15 14 8. BLK/PPL 16. BRN/PPL

Armor 1: Coaxial cable


2 to 19: Twisted pair cable

Cable type 10S1258-1, sectional view

2-4
Fabrication of connector 00-8016-038-313761HV (CN-A101)

320
45 Anticorrosive
Shield Sheath
40

Vinyl Sheath
Armor

Core Insulating Tape

After exposing cores,


wind shield around the armor.

Fabrication of cable for connector 00-8016-038-313761HV

Guide Pin A
Guide Pin B

Position No.

Guide Pin A Guide Pin B


(Large) (Small)

Assembling 38P connector

Positioning guide pins


Guide pins of the connector identify the mating receptacle. They are;
• Guide pin A (Large): 1
• Guide pin B (Small): 1

2-5
2.3.2 Power cable
Attach the NCS-253-P connector (CN-A110) to the power cable DPYCY-1.5 (Japan
Industrial Standard (JIS) cable) or the equivalent. Attach the connector to the processor unit.
Cable DPYCY-1.5

Armor Vinyl sheath

Armor

Vinyl
Taping sheath
Solder lead wire to armor and
connect it to #1 pin of connector.
Conductor
Use cable DPYCY-1.5 2
(Japan standard cable) S = 1.5 mm
or equivalent cable. ∅ = 1.56 mm

Assembling connector NCS-253-P

2.3.3 Control cable


Attach the control cable (10S2074 or 10S2075) to the CN-A103 connector in the processor
unit.

2-6
2.3.4 Optional equipment
With connection of a navigator and electronic fishing equipment, the FSV-30 provides true
motion presentation, target lock, echo sounder picture, FNZ marker presentation, and digital
indication of position, water temperature and depth.

Use the SRCN connectors (optionally supplied, Type: CP10-4801, Code no.: 006-934-240)
to connect equipment to the rear of the processor unit. Refer to the interconnection diagram
at the back of this manual.

Cable list

Outline of core
Simple
w/shield
Twisted

Sectional view of cables

02S8040

No. Color
1 WHT/BLU
9 mm 2 BLK
3 PNK
Shield 4 GRN
5 ORG
6 YEL
7 RED

CO-SPEVV-SB-C 0.2sq, 5P

No. Color
1 YEL/BLK
2 YEL/WHT
Shield 14 mm 3 YEL/RED
4 YEL/BLU
5 YEL/GRN
Armor

2-7
J5 (CIF1) : SRCN6A13-5P
J7 (GYRO) : SRCN6A16-10P
Cable with armor J8 (LOG) : SRCN6A13-3P
J10 (FNZ) : SRCN6A21-10P
J13 (EXT-KP) : SRCN6A21-10S

8 cm
1 cm 2 cm
Armor Shield
3 mm
Vinyl sheath

Solder unused cores and Clamp fixing screw


earth to braided shield.
Clamp
Wind shield Set screw
Solder earth wire. tape.

Connector case

Soldering side

Wind vinyl tape. Attach conector at


shield to ground.

J9 (ES1) : SRCN6A16-7P
Cable without armor
J12 (ES2/NET) : SRCN6A16-10P

2 cm
Shield
3mm
Vinyl sheath

Clamp fixing screw


Solder unused cores and
earh wire to braided shieeld. Clamp
Set screw

Vinyl sheath

Wind vinyl tape Connector case

Soldering-side

2-8
Synchronizing with echo sounder or other sonar
To synchronize the transmission of the FSV-30 with an echo sounder or other type of sonar,
make connections as shown below.

For current driven KP input

Processor EXT-KP
unit
KP signal

EXT-KP-IN-H 8 E/S
EXT-KP-IN-C 9 Sonar

For voltage driven KP (12 V) input

Processor EXT-KP
unit
KP signal

EXT-12VKP-H 10 E/S
0V 7 Sonar

Voltage driven KP output


Processor EXT-KP KP signal
unit
INTKP1 1
E/S,
GND 2 Sonar,
INTKP2 3
Current
GND 4
indicator
INTKP3 5
GND 6

Menu setting
See EXT KP INPUT on page 3-9.

2-9
2.4 Transceiver Unit
2.4.1 Fabrication of connector 00-8016-038-313761HV (CN-B101)
400
45 Anticorrosive
Shield Sheath
40

Vinyl Sheath
Armor

Core Insulating Tape

After exposing cores,


wind shield around the armor.

Fabrication of cable for 00-8016-038-313761HV


Shorten the unused wires appropriately and treat their ends with vinyl tape to prevent short
circuit.

Guide Pin A
Guide Pin B

Position No.

Guide Pin A Guide Pin B


(Large) (Small)

Assembling 38P connector

Positioning guide pins


Use the tool shown below to position guide pins.
Connector Tool
CN-B101
Guide Pin
Guide Pin A (large) 1
Guide Pin B (small) 1

2-10
13-L

CN-B210 CN-B209 CN-B208 CN-B207 CN-B206 CN-B205 CN-B204 CN-B203 CN-B202 CN-B201

6962 6963

16-L
CN-B101
CN-B102

VH-3P
TRX-10 TRX-9 TRX-8 TRX-7 TRX-6 TRX-5 TRX-4 TRX-3 TRX-2 TRX-1

SB-1909
SB-1909

EDS3

07-L
EDS3

05-L

EDS3

SM4P
EL12P EL9P SM18P EL3P
SM8P SM12P

J601
F601 F602
J201 J202 J203 J204 J205 J206
MAIN
5A 5A I
MAINTENANCE
INPUT
I TB-B101
Maintenance
Use Only. 100/110/115
(Should be OFF /220/230 VAC
for Normal :15A
operation.) 50/60Hz
1 2
J301 J302 J303
S603 S604 S605
H H H

TB-B101
SM12P EL4P
YL8P
INPUT(TB-B101) S603 S604 S605
100V L L L
110V H L L
115V H H L
15A 15A
220V H L H
230V H H H

L L L

To Processor Unit
(cable 10S1258-1)

To Hull Unit
(cable 10S2078)

To Power Source

Transceiver unit, inside view

2-11
2.4.2 Fabrication of power cable type DPYCYS-2.5 (TB-B101)
Fabricate the cable DPYCYS-2.5 as below for connection to the power source.
Cable DPYCYS-2.5

Armor

Vinyl
sheath

Conductor
S = 4 mm 2
∅ = 2.55 mm

140
35
30

FV2-4 (2 pcs)

Anticorrosive Amor Vinyl sheath


sheath
Fabrication of cable type DPYCYS-2.5

2.4.3 Hull control cable (10S2078)


Connect the hull control cable (10S2078) to the CN-B102 in the transceiver unit.

Note: The same type of connector is fitted at each end, however the connector which has a
larger portion of its sheath removed should be connected to the transceiver unit.

2-12
2.4.4 Wiring in transceiver unit
1. Open the transceiver unit cover.
2. Plug the P1 and P2 connectors at the end of signal cables into the proper receptacles in
the transceiver unit, referring to the interconnection diagram at the back of this manual.
3. Lead the signal cables into the transceiver unit appropriately.
4. Fasten the cables with cable clips after wiring the hull unit.
From right to left B201 to B210
P2
(40 pin)
13-L

P1
(34 pin)
CN-B210 CN-B209 CN-B208 CN-B207 CN-B206 CN-B205 CN-B204 CN-B203 CN-B202 CN-B201

6962 6963

16-L

VH-3P
TRX-10 TRX-9 TRX-8 TRX-7 TRX-6 TRX-5 TRX-4 TRX-3 TRX-2 TRX-1

SB-1909
SB-1909

EDS3

07-L
EDS3

10S2223 Cable clip


05-L

EDS3

SM4P
EL12P EL9P SM18P EL3P
SM8P SM12P

J601
F601 F602
J201 J202 J203 J204 J205 J206
MAIN
5A 5A I
MAINTENANCE
INPUT
I TB-B101
Maintenance
Use Only. 100/110/115
(Should be OFF /220/230 VAC
for Normal :15A
operation.) 50/60Hz
1 2
J301 J302 J303
S603 S604 S605
H H H
SM12P EL4P
YL8P
INPUT(TB-B101) S603 S604 S605
100V L L L
110V H L L
115V H H L
15A 15A
220V H L H
230V H H H

L L L

Secure
here with
metal clamp.
Fix signal cables with clamp.

Transceiver unit

10 9 8 7 6 5 4 3 2 1
Cable
number

Transceiver unit, top view

2-13
2.5 Cable Extension Kit
The length of the cable between the hull unit and transceiver unit is 5 meters. If a longer
cable is required, use the cable extension kit, which consists of a junction box and a 5 or 15
meter cable.

Connect the transducer cable 10S2223 to the junction box, and connect the transceiver unit
to the junction box with the cable 10S2240 (5 or 10 m).

Replace the cable (10S2078, 8 m) connected between the hull unit and transceiver unit with
the cable 10S2144 (12.9 m) or 10S2145 (22.9 m). Those cables are supplied with the
extension cable kit.

2.5.1 Junction box


Connect the extension cable 10S2240 to JCTN1 and JCTN2 inside the junction box. Also,
connect the transducer cable 10S2223. Refer to interconnection diagram for wiring details.

1. Open the junction box cover.


2. Unfasten the cable clamps.

P1 P3 P1 P3 JCTN1
Board
Connect to Connect to Connect to Connect to
the J20 in the J19 in the J2 in the J1 in J1

JCTN1 Board JCTN1 Board JCTN1 Board JCTN1 Board


J20 J19 J2 J1

J20 J19 J2 J1
J1

P2 JCTN2
P4 P2 P4 Board
Connect to Connect to Connect to Connect to
the J20 in the J19 in the J2 in the J1 in
JCTN2 Board JCTN2 Board JCTN2 Board JCTN2 Board CSK
clamp

Cable from Cable from Cable from Cable from


hull unit transceiver unit hull unit transceiver unit
(10S2223) (10S2240) (10S2223) (10S2240)

Cable clamp

Signal cables Junction box


(10S2223)
from hull unit
10 9 8 7 6 5 4 3 2 1

10 9 8 7 6 5 4 3 2 1

Signal cables (10S2240) from transceiver unit


("JUNCTION BOX" display side)

Junction box, cover removed

2-14
3. Lead in cable thru the appropriate location on the cable clamp and fix cable with
appropriate CKS clamp. Connect each cable to circuit board as shown in the figure on
the previous page.
Signal cable (10S2240) connects to “JUNCTION BOX” display side.
4. Lay the shield of each cable in the cable clamp.
5. Fasten the cable clamps.

2-15
2.5.2 Raise/Lower control box
Connect the power cable (3φ) and the transceiver unit cable (10S2078) as shown below.

CN-C101
Connect the transceiver
cable (10S2078) here.

Cable TPYCY-4

Sheath
TB-C101
Connect the power cable TPYCY-4 Armor
(Japan Industrial Standard) or the
equivalent cable to this terminal board.
Vinyl
LED (Red) sheath
For detection of phase reversal on Conductor
3 phase power cable S = 4 mm2
∅ = 2.55 mm

Confirm LED after completing the installation. The LED lights (in red) if power connection is
correct. If it is off, turn off power from the mains switchboard, check the cable connection
and recheck the LED. The hull unit does not work if this connection is wrong.
Normal phase: LED lights (in red).
Phase reversal: LED does not light.

Power cable (3φ)


TPYCY-4
Cable from
transceiver unit
10S2078
Raise/lower control box, cover removed

2-16
100
25
20 M4(yellow) x 3

FV5.5-4
Vinyl Armor Sheath
sheath (Clamp here by cable clamp.)

Power cable fabrication

2-17
2.6 Input Voltage and Fuses
The transceiver unit is shipped from the factory with its input voltage set for 230 VAC and a
10 A fuse inserted in F601 and F602. For other voltages, change toggle switch positions
and fuses as below.

Input voltage
Set the toggle switches S603, S604 and S605 according to input voltage, referring to the
table below.

Input S603 S604 S605 Default setting


(TB-B101)
100 V L L L
110 V H L L
115 V H H L
220 V H L H
230 V H H H Default setting

Fuses
Change the fuse in F601 and F602 according to input voltage, referring to the table below.

Input Fuse Default


(TB-B101) F601 F602 setting WARNING
100 V
Use the proper fuse.
110 V 20A 20A
115 V Use of a wrong fuse can result in damage
to the equipment or cause fire.
220 V Default
10A 10A
230 V setting

Marking the label


After setting toggle switches and changing the
fuses, mark the voltage which applies on the label
on the inside of the cover. In the example shown
right, 100 V is marked so 20A fuses must be used. FUSE FUSE

F601 F602

INPUT FUSE
(TB-B101) F601 F602
100V
110V 20A 20A
115V
220V
10A 10A
230V

2-18
3. ADJUSTMENT AND CHECK
3.1 Hull Unit Check
Note: Before conducting this check (at the dry dock) transmission must be stopped. Default
setting of TX power is OFF. Confirm that transmission is off as follows:

1. Turn on the power, and then press the [MENU] key to show the main menu.
MENU QUIT
TX PULSE LENGTH-H :9
TX POWER-H :9
TVG-NEAR-H :0
TVG-MEDIUM-H :0
TVG-FAR-H :0
AGC-H :0
2ND AGC-H :0
ECHO AVERAGE-H :0
COLOR-H : COLOR 1
COLOR RESPONSE-H : COLOR CURVE 3

H-SCAN SETTING...
V-SCAN SETTING...
OTHERS...

Main menu
2. Use the trackball to choose OTHERS and press the [MENU] key.
MENU QUIT
OTHERS QUIT

ES1 SETTING...
ES2 SETTING...
ERASE MARKS...
DISPLAY SETTING...
ALARM & AUDIO...
PRESET, MEMORY CARD...
INITIAL SETTING...

OTHERS menu

3-1
3. Choose INITIAL SETTING and press the [MENU] key.
CAUTION YES
THIS ITEM IS DEFINED AS NON-
CHANGEABLE ITEM, ARE YOU NO
SURE TO CHANGE IT TO CHANGEABLE ?

4. Choose YES and press the [MENU] key.


MENU QUIT
OTHERS QUIT
INITIAL SETTING QUIT
MARK DISPLAY...
MARK SIZE...
DATA DISPLAY...
CURRENT VEC & WIND...
NET SONDE SETTING...
NET SHOOT SETTING...
TARGET LOCK...
STABILIZATION...
TEST...
INITIALIZATION...

INITIAL SETTING menu


5. Choose TEST and press the [MENU] key.
MENU QUIT
OTHERS QUIT
INITIAL SETTING QUIT
TEST QUIT
BOARD TEST...
PANEL TEST...
TEST PATTERN...
RX TEST...
NOISE TEST...
TX : OFF

TEST menu
6. Choose TX and press the [MENU] key.
7. Choose OFF (if it is not already selected) and press the [MENU] key.
8. Choose QUIT at the top of the menu screen and press the [MENU] key.

3-2
How to check the hull unit
1. Press the POWER (|) switch on the control unit to turn on the equipment. Confirm that
“ ON” lamp above the POWER switch and theª switch light.

Transducer switches of the control unit


2. Confirm that the 5V and UP lamps on the raise/lower control box are lit.
3. Remove the cover of the raise/lower control box and use a multimeter to measure the
following voltages:

Terminal Terminal No. Voltage


TB-C101 (1) – (2), (6) – (7) 220 VAC
(2) – (3), (7) – (8) 220 VAC
(1) – (3), (6) – (8) 220 VAC

4. In the raise/lower control box, set the TEST/NORMAL switch to TEST. Press the
[DOWN] switch to confirm that the transducer lowers. Also, while the transducer is being
lowered, check that the MD LED lights when the MD L. SW kicks. Note that the MD L.
SW does not stop the transducer when the TEST/NORMAL switch is in the TEST
position.
TEST

OFF
NORMAL 5V
L.SW

UP MD DN

UP DOWN

Control unit (in hull unit)


5. Press and release the [DOWN] switch. Confirm that the transducer stops at the moment
the switch is released.
6. Press the [DOWN] switch again. Confirm that the transducer stops at the moment the
lower limit switch kicks.
7. Confirm that the [UP] switch operates in a similar manner.

3-3
8. Check that LEDs on the panel of the raise/lower control box light as follows:
1) UP, MD and DN LEDs light when corresponding limit switch is kicked.
2) UP and DOWN LEDs light while UP and DOWN switches are pressed and extinguish when
the switches are released.
3) Set the TEST/NORMAL switch to NORMAL.
9. At the control unit, press the ª (mid position) switch. Confirm that the lamp above the
switch blinks while the transducer is being lowered, a short beep sounds when the mid
limit switch kicks, and the lamp lights when the transducer is lowered to the mid position.
10. Press the ª switch. Confirm that the lamp above the switch blinks while the transducer
is being lowered, a short beep sounds when the mid limit switch is kicked, and the lamp
lights when the transducer is fully lowered.
11. Press the © switch. Confirm that the lamp above the switch blinks while the transducer
is being raised, a short beep sounds when the mid limit switch is kicked, and the lamp
lights when the transducer is fully raised.
12. Press the OFF switch. Confirm that the transducer is completely retracted and then the
power is turned off.
13. With the transducer lowered (mid or fully lowered), confirm that the transducer is raised
when © or OFF is pressed.

3-4
3.2 Heading Adjustment
When the BOW mark on the flange of the hull unit cannot be directed toward ship’s bow,
adjust the heading so an echo which is dead ahead appears dead ahead on the display.

1. Referring to the previous section, set the TX (transmission) to ON.


2. Locate a target in the bow direction (buoy, for example) and display it on a near range. If
the target appears at 12 o’clock the heading alignment is correct. If it does not, measure
the error and go to step 2.

Buoy If target's on-screen


position is right of ship's
bow for example, heading
is skewed left.

Heading adjustment
3. Turn off the power and then turn it on again while pressing and holding down the
[MENU] key. Release the [MENU] key after the self-test screen appears. After the picture
appears, press the [MENU] key three times to open the SYSTEM menu.
SYSTEM MENU QUIT
INTERFACE SETTING..
EXT DATA SETTING..
OWN SHIP MARK..
TEST&INITIALIZATION..
TX/RX SETTING..
TX/RX SETTING - H..
TX/RX SETTING - V..
OTHERS..

SYSTEM menu
4. Use the trackball to choose OTHERS and press the [MENU] key.
5. Choose HEADING ADJUST and press the [MENU] key.

3-5
MENU QUIT
OTHERS QUIT
LANGUAGE : ENGLISH
HEADING ADJUST :0 QUIT
CANCEL
ES2 SELECT : ES
ES DRAFT OFFSET : 0.0 m
EVENT KEY : EVENT
AUTO TILT : WIDE
SELECT USER PROG : H/V INTERLOCK

TRACKBALL SPEED : NORMAL


HULL UNIT STROKE : 1200mm

OTHERS menu, HEADING ADJUST


6. Choose ▲ or ▼ to choose direction (plus or minus, respectively) in which to increment
or decrement setting and then press the [MENU] key to set. Each pressing of the
[MENU] key changes the setting in increments of 1°. The setting range is -180° to +179°.
7. Choose QUIT to finish the adjustment and press the [MENU] key.
8. Choose QUIT at the top of the menu screen and press the [MENU] key to close all
menus.

3-6
3.3 Configuring Own Ship Mark
Set own ship’s dimensions and the location of the transducer to accurately display the own
ship mark on the display.

1. Press the [MENU] key to display the SYSTEM menu.


SYSTEM MENU QUIT
INTERFACE SETTING..
EXT DATA SETTING..
OWN SHIP MARK..
TEST&INITIALIZATION..
TX/RX SETTING..
TX/RX SETTING - H..
TX/RX SETTING - V..
OTHERS..

System menu
2. Use the trackball to choose OWN SHIP MARK and press the [MENU] key.
MENU QUIT
OWN SHIP MARK QUIT

SHIP'S LENGTH : 75m


SHIP'S WIDTH : 20m
TD POSITION 1 : 15m
TD POSITION 2 : 0.0m

OWN SHIP MARK menu


3. Use the trackball to choose SHIP’S LENGTH.
4. Press the [MENU] key to show the setting window.
MENU QUIT
OWN SHIP MARK QUIT

SHIP'S LENGTH : 75m QUIT


CANCEL
SHIP'S WIDTH : 20m
TD POSITION 1 : 15m
TD POSITION 2 : 0.0m

OWN SHIP MARK menu, setting window

3-7
5. Choose ▲ or ▼ and then operate the [MENU] key to set the ship’s length (15 to 150 m).
6. Choose QUIT to finish the setting.
7. Set the SHIP’S WIDTH (5 to 30 m), TD POSITION 1 (5 to 50 m) or TD POSITION 2
(-10.0 to 10.0 m) similarly.
TD POSITION 1: Set the transducer’s distance from the bow.
TD POSITION 2: Set the transducer’s distance from the keel. Choose [+] for starboard,
[-] for port.
8. Choose QUIT at the top of the menu screen and press the [MENU] key to close all
menus.

TD Position 1

Ship's
Length

TD Position 2
(Negative value
for port)

Ship's Width

Ship shape description

3-8
3.4 Other SYSTEM Menu Items
This section mainly shows you how to set up according to external equipment connected.
Default settings are underlined.

3.4.1 INTERFACE SETTING menu

MENU QUIT
INTERFACE SETTING QUIT

NMEA 1 BAUD RATE: 4800 bps


NMEA 2 BAUD RATE: 4800 bps
CIF BAUD RATE : 4800 bps
AUX BAUD RATE : 19200 bps

EXT KP INPUT : DISABLE


EXT KP OUTPUT : NEGATIVE

INTERFACE SETTING menu


NMEA 1 BAUD RATE
Set the transmission rate for the NMEA 1 port.
(4800 bps, 9600 bps, 19200 bps, 38400 bps)

NMEA 2 BAUD RATE


Set the transmission rate for the NMEA 2 port.
(4800 bps, 9600 bps, 19200 bps, 38400 bps)

CIF BAUD RATE


Set the transmission rate for the CIF port. If the CS-120A is connected, choose “2400 bps”.
(2400 bps, 4800 bps, 9600 bps, 19200 bps)

AUX BAUD RATE


Set the transmission rate for the AUX port. (2400 bps, 4800 bps, 9600 bps, 19200 bps)

EXT KP INPUT
Set the input logic of KP from an external equipment. (DISABLE, POSITIVE, NEGATIVE)
DISABLE: No use external KP.
POSITIVE: Synchronize with leading edge of input pulse.
NEGATIVE: Synchronize with trailing edge of input pulse
Note: To transmit with external KP, set the TX INTERNAL to “0” in the H-SCAN SETTING
menu.

EXT KP OUTPUT
Choose the KP output logic, POSITIVE or NEGATIVE. (POSITIVE, NEGATIVE)

3-9
3.4.2 EXT DATA SETTING menu
MENU QUIT
EXT DATA SETTING QUIT

DATE&TIME : CIF
HEADING : AD10S
LOG PULSE : 200p/NM
SPEED&COURSE : NMEA
SPEED SENSOR : GPS/DR
LAT/LON : NMEA
POSITIONING SENSOR : AUTO SEL.

WATER DEPTH : NMEA


WATER TEMP. : NMEA
WATER CURRENT : CIF
WIND : CIF
NET DEPTH : PULSE

EXT DATA SETTING menu

DATE & TIME


Choose the input format for data and time data. (NONE, CIF, NMEA)

HEADING
Choose the input format for heading data. (NONE, AD10S, CIF, NMEA)

LOG PULSE
Set the log pulse rate for the log signal. (200 p/NM, 400 p/NM)

SPEED & COURSE


Choose the input format for ship’s speed and course data. When choosing the
LOG&HEADING, the heading data is used instead of the course data.
(NONE, LOG&HEADING, CIF, NMEA)

SPEED SENSOR
Choose the input format for speed and course data. This setting is ineffective when
LOG&HEADING is selected as speed and course source.
(NONE, GPS/DR, DOPPLER/DR)

LAT/LON
Choose the input format for ship’s position data. (NONE, CIF, NMEA)

POSITIONING SENSOR
Choose the type of the navigator to use. For AUTO SEL., the priority is GPS/DR>LORAN-C.
(LORAN-C, GPS/DR, AUTO SEL.)

3-10
WATER DEPTH
Choose the input format for depth data. (NONE, CIF, NMEA)

WATER TEMP.
Choose the input format for water temperature data. (NONE, CIF, NMEA)

WATER CURRENT
Choose the input format for water current data. (NONE, CIF, NMEA)

WIND
Choose the input format for wind data. (NONE, CIF, NMEA)

NET DEPTH
Choose the input format for net depth data. (NONE, CIF, PULSE)

Data sentences (NMEA 0183, FURUNO proprietary)


NMEA Input
Position (L/L) GGA, GLL, GNS, RMA, RMC
Heading HCC, HCD, HDG, HDM, HDT
Course VTG
Speed VBW, VHW
Current CUR, VDR
Depth DBS, DBT, DPT
Temperature MTW
Wind MWV
Date Time ZDA
GPS gyro Att (FURUNO proprietary data sentence)

NMEA Output
Position TLL

FURUNO proprietary data sentences (all output)


Fish school speed FKV
Relative bearing, range depth and speed of fish school TFM
Relative bearing, range and depth of position tracking mark TLM
Bearing, range and depth of event mark EVT
Bearing, range, depth and volume of fish estimate mark FMG
Bearing, range, depth and speed of fish school mark FVC
Bearing and range of net shoot mark SHT
Scattering strength (SV), area, volume and abundance of fish school TLF
Scan setting parameter (1 to 6) at each Tx SD3 - SD8

3-11
3.4.3 OTHERS menu
MENU QUIT
OTHERS QUIT
LANGUAGE : English
HEADING ADJUST :0
ES2 SELECT : ES
ES DRAFT OFFSET : 0.0 m
EVENT KEY : EVENT
AUTO TILT : WIDE
SELECT USER PROG : H/V INTERLOCK

TRACKBALL SPEED : NORMAL


HULL UNIT STROKE : 1200mm

OTHERS menu

LANGUAGE
Choose the language to use. (JAPANESE, ENGLISH)

HEADING ADJUST
See “3.2 Heading Adjustment”.

ES2 SELECT
Choose the equipment connected to the ES2 port; echo sounder or net recorder.
(ES, NET REC)

ES DRAFT OFFSET
When connecting an echosounder, you may enter the ship’s draft if you prefer to display
depth from the draft rather than depth from the transducer. (0.0 m to 10.0 m, increments of
0.1 m)

EVENT KEY
Choose the key to use to enter own ship’s position, EVENT or SHOOT. When choosing
SHOOT, the shoot function becomes inoperative. (EVENT, SHOOT)

AUTO TILT
Choose the range for the auto tilt form WIDE (±2 to 10°, ±4 to 16°, ±6 to 20°) or NARROW
(±1 to 4°, ±2 to 6°, ±3 to 8°). (WIDE, NARROW)

SELECT USER PROG


Choose whether to program horizontal and vertical displays together or individually, by the
USER PROG control. H/V INTERLOCK, the default setting, commonly applies control
settings to the horizontal and vertical displays. H/V INDVIDUAL enables individual
adjustment of horizontal and vertical displays.

3-12
TRACKBALL SPEED
Choose the speed of trackball movement (inside menu window only).
(SLOW, NORMAL, FAST)

HULL UNIT STROKE


Choose the stroke length of the hull unit. (1200 mm, 1600 mm).

3.5 CONE Board Setting in the Processor Unit


Adjust the potentiometers on the CONE Board in the processor unit, referring to the table
shown below.

Location Name Resistance Function Adjustment


No. value
R118 ALARM 10 kΩ Adjust the volume of audio CW: Large
alarm. CCW: Small
R119 ES2_OFF 1 kΩ Adjust ES2 signal offset. CW: Noise decrease
CCW: Noise increase
R167 ES2_GAIN 10 kΩ Adjust ES2 signal gain. CW: Gain increase
CCW: Gain decrease
R168 ES1_OFF 1 kΩ Adjust ES1 signal offset. CW: Noise decrease
CCW: Noise increase
R209 ES1_GAIN 10 kΩ Adjust ES1 signal gain. CW: Gain increase
CCW: Gain decrease

3.5.1 Adjustment of signal level (echo sounder connected)


Adjusts the output level of the echo sounder on the CONE Board as below.

1. Choose an echo sounder display (ES1 or ES2) from the menu.


2. For ES1, adjust R168 to suppress noise, and then adjust R209 so that the picture
condition is similar to that of connected echo sounder connected to the FSV-30.
3. For ES 2, adjust R119 to suppress noise, and then adjust R167 so that the picture
condition is similar to that of echo sounder connected to the FSV-30.

3.5.2 Adjusting the volume of the audio alarm


The volume of the audio alarm cannot be adjusted from the control unit. If necessary, adjust
R118 on the CONE Board to choose appropriate volume.

3-13
3.6 DIP Switch Setting

J496, J497

C
DCON board (10P6984 or 10P6984A) DC
A

4 96
J
97
J4

IFES board (10P6983) IFE


SSCSAC
D
NAUN
A2DL
CO
N

J1
J1

Processor unit, inside view

3.6.1 CIF2/NMEA2 connector interface selection


The signal format for the CIF2/NMEA2 port (at the back of the processor unit) can be set for
CIF or NMEA by DIP switch S2-8 on the IFES Board (10P6983). The default format is OFF
(CIF).

DIP switch setting Format


S2-#8: ON NMEA
S2-#8: OFF CIF

S2

IFES Board (10P6983)

3-14
3.6.2 Choosing echosounder signal
There are two kinds of echosounder signals, AC signal and DC signal. Set the appropriate
jumper on the CONE board as below according to the input port. The default setting is AC.
See page 3-14 for parts location.

Input port Jumper


ES1 J497
ES2/NET J496

Note: The SIGOUT (AC signal) terminal and REC terminal (DC signal) in the output port
are provided for a FURUNO echosounder. Therefore, when using the SIGOUT
terminal, it is not necessary to change the above-mentioned jumper setting.

3-15
(This page intentionally left blank.)

3-16
4. CONNECTING THE EXTERNAL
INTERFACE CS-120A
When upgrading from the CSH-20 series sonar, the External Interface CS-120A can be
used. Connect the CS-120A to the processor unit as shown on the next page. However, we
recommend that you connect external devices directly to the processor unit, to avoid signal
delay.

Install the following power supply kit (option) in the processor unit to enable use of the
CS-120A.

Name: Power Supply Kit Type: FSV-2403 Code No.: 000-067-013


Name Type Code No. Qty Remarks
Power supply pcb LEA50F-24-XFND 000-143-913 1
Spacer SQ-22 000-159-305-10 4
Protection sheet 10-071-3508 100-290-712 1
Screw M3×8 C2700W 000-163-190-10 4
Connector (NJC) NJC-203-PM 000-160-184-10 1

1. Unfasten seven screws to remove the front cover of the processor unit.

Screw
M4x8, 7 pcs. DC
ON

FUR
UN
O

WA
RN
ING

Details
omitted

Processor unit, front view

4-1
2. Remove two upset screws, detach the plugs J503, J502, J501, J504, J506 and J507,
and then pull out the power module.
Protection sheet

VH4P
Spacer

Detach J503, J502, IFE


S
SC
AN

Power supply J501, J504 and


SC
AN
2D
UA
L
DC

VH5P J506.
ON

pcb
Power Module
Upset screws
M5x25 SUS 2 pcs.

Pin
Hole

Detach J507.

Processor unit, front view


3. Fix the power supply pcb (supplied) to the power module with spacers (supplied).
4. Connect two VH connectors (provided on the power module) to the power supply pcb.
5. Set the protection sheet (supplied) to the power supply pcb and fasten it with four
screws.
6. Reattach the power module.
7. Connect between the processor unit and CS-120A as follows.

Processor Unit POWER FOR CS-120A port CS-120A


NJC-203-PM J201
YEL BRN
+24V_H 1 L 24V
ORG BRN
+24V_C 2 E 0V
PPL BRN
GND 3 PP GND
CIF1 or NMEA2/CIF2
port
CIF_TXD_H 1 NN TD-H
CIF_TXD_C 2 MM TD-C
CIF_RXD_H 3 JJ RD-H
CIF_RXD_C 4 KK RD-C
SHIELD 10 BB GND
EE DSR-C
DD DSR-H
Z DTR-H

37-core cable
10S1258

Wiring between processor unit and CS-120A


Note: An echosounder should be connected to the processor unit directly.

4-2
8. Set the DIP switch on the DCON Board as follows.

Input port DIP switch setting on DCON Board


CIF1 S3-#2: ON
NMEA 2/CIF 2 S3-#3: ON
S3

DCON Board (10P6984 or 10P6984A)

Note: If the CIF1 format is selected, change baud rate to 2400 bps. See CIF BAUD RATE
on page 3-9 for details.

4-3
(This page intentionally left blank.)

4-4
10CT-X-9851 -2 1/1
PACKING LIST A-1 A-2
FSV-3002-60-J/E,FSV-3002-70-J/E,FSV-3002S-60-E/70-E %1&'01  %1: 
6;2' %2 
N A M E O U T L I N E DESCRIPTION/CODE № Q'TY
ユニット UNIT
制御部 FSV-3002-60 Ꮏ੐᧚ᢱ⴫
1
PROCESSOR UNIT +056#..#6+10/#6'4+#.5
000-067-043 ** ⇟ภ ฬ‫ޓޓ‬⒓ ⇛‫ޓޓ‬࿑ ဳฬ㧛ⷙᩰ ᢙ㊂ ↪ㅜ㧛஻⠨
01 0#/' 176.+0' &'5%4+26+105 3 6; 4'/#4-5
予備品 SPARE PARTS
予備品 SP10-02601 㩄㩒㩂㩊
㧕 ೙ᓮㇱ↪
(14241%'551470+6
 *8( 
1 %100'%614

SPARE PARTS
%1&'01
006-921-340 
㩄㩧㩊㩂㩎㩕㩩㩧㧔 ( ೙ᓮㇱ↪
付属品 ACCESSORIES (14241%'551470+6
付属品 FP10-02901   
%106#%62+0

1 %1&'01 
ACCESSORIES 
007-008-780 ౐ⷺ㩇㩢㩦㩢㩈㩛㩇$ /:575 ೙ᓮㇱ↪
(14241%'551470+6
工事材料 INSTALLATION MATERIALS  /:575 
*':$1.6
工事材料 CP10-04506
5.166'&9#5*'4*'#& %1&'01 

1 0%52 41*5
INSTALLATION MATERIALS 㩄㩒㩂㩊
0%5 ೙ᓮㇱ↪
(14241%'551470+6
006-921-290  0%52 
%100'%614
0%5
工事材料 CP10-04502 %1&'01 

1
INSTALLATION MATERIALS
006-921-240
図書 DOCUMENT
電源設定書 C12-00302-*

1
INPUT JOLTAGE SETTING
000-149-243
取扱説明書(英) OME-13231-*

1
OPERATOR'S MANUAL
000-148-731 (*1)
装備要領書(和) IMJ-13230-*

1
INSTALLATION MANUAL
000-148-573 **
取扱説明書(和) OMJ-13230-*

1
OPERATOR'S MANUAL
000-148-571 **

1.䍘-䍢䍼⇟ภᧃየ䈱[**]䈲䇮ㆬᛯຠ䈱ઍ⴫ဳᑼ/䍘䍎䍢䉕⴫䈚䉁䈜䇯
CODE NUMBER ENDED BY "**" INDICATES THE NUMBER OF TYPICAL MATERIAL.
2.(*1)䈱ขᛒ⺑᣿ᦠ(⧷)䈲䍂FSV-30Sኾ↪䈪䈜䇯
*1 FOR FSV-30S.
ဳᑼ㩄㨺㩎㩨⇟ภ߇㧞Ბߩ႐ว‫ޔ‬ਅᲑࠃࠅ਄Ბߦઍࠊࠆㆊᷰᦼຠߢ޽ࠅ‫ޔ߅ߥޓޕߔ߹޿ߡߞ౉߇߆ࠄߜߤޔ‬ຠ⾰ߪᄌࠊࠅ߹ߖࠎ‫ޕ‬

6916;2'5#0&%1&'5/#;$'.+56'&(14#0+6'/6*'.19'4241&7%6/#;$'5*+22'&+02.#%'1(6*'722'4241&7%6
37#.+6;+56*'5#/'
㧔⇛࿑ߩኸᴺߪ‫ޔ‬ෳ⠨୯ߢߔ‫&ޓޕ‬+/'05+105+0&4#9+0)(144'('4'0%'10.;㧕 %1:
(略図の寸法は、参考値です。 DIMENSIONS IN DRAWING FOR REFERENCE ONLY.)
㧲㨁㧾㨁㧺㧻‫ޓ‬㧱㧸㧱㧯㨀㧾㧵㧯‫ޓ‬㧯㧻‫ޓ‬㧚㧘㧸㨀㧰
10CT-X-9851
10CT-X-9852 -0 1/1
A-3 PACKING LIST A-4
%1&'01  %1: 
FSV-301
6;2' %2 
N A M E O U T L I N E DESCRIPTION/CODE № Q'TY
ユニット UNIT
Ꮏ੐᧚ᢱ⴫ 送受信装置 FSV-301

1
+056#..#6+10/#6'4+#.5 TRANSCEIVER UNIT
⇟ภ ฬ‫ޓޓ‬⒓ ⇛‫ޓޓ‬࿑ ဳฬ㧛ⷙᩰ ᢙ㊂ ↪ㅜ㧛஻⠨ 000-067-047
01 0#/' 176.+0' &'5%4+26+105 3 6; 4'/#4-5 予備品 SPARE PARTS
㩄㩒㩂㩊
54%0㧕 予備品 SP10-03101
 54%0#2 
%100'%614
54%0 1
SPARE PARTS
%1&'
01  007-008-530
㩄㩒㩂㩊
54%0㧕 工事材料 INSTALLATION MATERIALS
 54%0#2  工事材料 CP10-06201
%100'%614
54%0
%1&' 1
01  INSTALLATION MATERIALS
007-008-540

ဳᑼ㩄㨺㩎㩨⇟ภ߇㧞Ბߩ႐ว‫ޔ‬ਅᲑࠃࠅ਄Ბߦઍࠊࠆㆊᷰᦼຠߢ޽ࠅ‫ޔ߅ߥޓޕߔ߹޿ߡߞ౉߇߆ࠄߜߤޔ‬ຠ⾰ߪᄌࠊࠅ߹ߖ
ࠎ‫ޕ‬
6916;2'5#0&%1&'5/#;$'.+56'&(14#0+6'/6*'.19'4241&7%6/#;$'5*+22'&+02.#%'1(6*'722'4
241&7%637#.+6;+56*'5#/'
㧔⇛࿑ߩኸᴺߪ‫ޔ‬ෳ⠨୯ߢߔ‫&ޓޕ‬+/'05+105+0&4#9+0)(144'('4'0%'10.;㧕
(略図の寸法は、参考値です。 DIMENSIONS IN DRAWING FOR REFERENCE ONLY.)
㧲㨁㧾㨁㧺㧻‫ޓ‬㧱㧸㧱㧯㨀㧾㧵㧯‫ޓ‬㧯㧻‫ޓ‬㧚㧘㧸㨀㧰 %1:
10CT-X-9852
%6:  
㧼㧭㧯㧷㧵㧺㧳‫ޓ‬㧸㧵㧿㨀
A-5 A-6
(58
%1&'01  %6: 
6;2' 
0#/' 176.+0' &'5%4+26+10%1&'ͳ 3 6;
%2
࡙࠾࠶࠻ 70+6
Ꮏ੐᧚ᢱ⴫ ਄ਅⵝ⟎
(58 
+056#..#6+10/#6'4+#.5 *7..70+6

⇟ภ ฬ‫ޓޓ‬⒓ ⇛‫ޓޓ‬࿑ ဳฬ㧛ⷙᩰ ᢙ㊂



↪ㅜ㧛஻⠨
176.+0' 3 6; ੍஻ຠ 52#4'2#465
01 0#/' &'5%4+26+105 4'/#4-5
ㅍฃାⵝ⟎↪
੍஻ຠ
㩄㩒㩂㩊
㧕
(1464#05%'+8'4 
 *8( 70+6 52
%100'%614
  52#4'2#465
%1&'
01  
⃻࿾⚵ㇱຠ .1%#.#55'/$.+0)‫ޓ‬2#465
㩄㩧㩊㩂㩎㩕㩩㩧
 ㅍฃାⵝ⟎↪
(1464#05%'+8'4 ⃻࿾⚵ㇱຠ⺑᣿
 ( 70+6
%106#%62+0
 
% 
%1&'
01 .1%#.#55'/$.+0)

࿶⌕┵ሶ (8 ㅍฃାⵝ⟎↪ 
(1464#05%'+8'4 1㩢㩧㩂㩨
8
 (8㨻㨿 70+6
%4+/210.7) 
%1&'  %1#
8 
01  14+0)
㨻㨺㩇᧼ 9'#41*5 ㅍฃାⵝ⟎↪ 
(1464#05%'+8'4
 9'# 70+6 㨻㨺㩇᧼
%122'4564#2 
%1&'  9'#41*5 
01  %122'4564#2

౐ⷺ㩘㩨㩣㩎‫ోޓ‬㩒㩆㩨
/:575 
*':#)10#.*'#&5%4'9

౐ⷺ㩏㨹㩎㩆㨷
/575 
*':076

㩚㩀㩨㩁ਣᐔᐳ㊄
/575 
(.#69#5*'4

㩔㩨㩒ᐳ㊄
/575 
524+0)9#5*'4

࿶⌕┵ሶ
(8
.( 
%4+/210.7)


ဳᑼ㩄㨺㩎㩨⇟ภ߇㧞Ბߩ႐ว‫ޔ‬ਅᲑࠃࠅ਄Ბߦઍࠊࠆㆊᷰᦼຠߢ޽ࠅ‫ޔ߅ߥޓޕߔ߹޿ߡߞ౉߇߆ࠄߜߤޔ‬ຠ⾰ߪᄌࠊࠅ߹ߖ
ࠎ‫ޕ‬
6916;2'5#0&%1&'5/#;$'.+56'&(14#0+6'/6*'.19'4241&7%6/#;$'5*+22'&+02.#%'1(6*'722'4
241&7%637#.+6;+56*'5#/' ဳᑼ㪆䍘䍎䍢䍼⇟ภ䈏䋲Ბ䈱႐ว䇮ਅᲑ䉋䉍਄Ბ䈮ઍ䉒䉎ㆊᷰᦼຠ䈪䈅䉍䇮䈬䈤䉌䈎䈏౉䈦䈩䈇䉁䈜䇯䇭䈭䈍䇮ຠ⾰䈲ᄌ䉒䉍䉁䈞䉖䇯
㧔⇛࿑ߩኸᴺߪ‫ޔ‬ෳ⠨୯ߢߔ‫&ޓޕ‬+/'05+105+0&4#9+0)(144'('4'0%'10.;㧕
㪫㪮㪦㩷㪫㪰㪧㪜㪪㩷㪘㪥㪛㩷㪚㪦㪛㪜㪪㩷㪤㪘㪰㩷㪙㪜㩷㪣㪠㪪㪫㪜㪛㩷㪝㪦㪩㩷㪘㪥㩷㪠㪫㪜㪤㪅㩷㩷㪫㪟㪜㩷㪣㪦㪮㪜㪩㩷㪧㪩㪦㪛㪬㪚㪫㩷㪤㪘㪰㩷㪙㪜㩷㪪㪟㪠㪧㪧㪜㪛㩷㪠㪥㩷㪧㪣㪘㪚㪜㩷㪦㪝㩷㪫㪟㪜㩷㪬㪧㪧㪜㪩㩷
㧲㨁㧾㨁㧺㧻‫ޓ‬㧱㧸㧱㧯㨀㧾㧵㧯‫ޓ‬㧯㧻‫ޓ‬㧚㧘㧸㨀㧰 %6: 㪧㪩㪦㪛㪬㪚㪫㪅㩷㪨㪬㪘㪣㪠㪫㪰㩷㪠㪪㩷㪫㪟㪜㩷㪪㪘㪤㪜㪅
䋨⇛࿑䈱ኸᴺ䈲䇮ෳ⠨୯䈪䈜䇯㩷㩷㪛㪠㪤㪜㪥㪪㪠㪦㪥㪪㩷㪠㪥㩷㪛㪩㪘㪮㪠㪥㪞㩷㪝㪦㪩㩷㪩㪜㪝㪜㪩㪜㪥㪚㪜㩷㪦㪥㪣㪰㪅䋩 %6:
%6:   %1:  
㧼㧭㧯㧷㧵㧺㧳‫ޓ‬㧸㧵㧿㨀 㧼㧭㧯㧷㧵㧺㧳‫ޓ‬㧸㧵㧿㨀
A-7 A-8
(58 (58 (58 (58
0#/' 176.+0' &'5%4+26+10%1&'ͳ 3 6; 0#/' 176.+0' &'5%4+26+10%1&'ͳ 3 6;
࡙࠾࠶࠻ 70+6 ࡙࠾࠶࠻ 70+6
਄ਅⵝ⟎ ᠲ૞ㇱ
(58  (58   
*7..70+6 %10641.70+6


 
੍஻ຠ 52#4'2#465 ઃዻຠ #%%'5514+'5
੍஻ຠ ઃዻຠ
52  (2 
52#4'2#465 #%%'5514+'5
 
⃻࿾⚵ㇱຠ .1%#.#55'/$.+0)‫ޓ‬2#465
⃻࿾⚵ㇱຠ⺑᣿
% 
.1%#.#55'/$.+0)

1㩢㩧㩂㩨
8
%1#
8 
14+0)

㨻㨺㩇᧼
9'#41*5 
%122'4564#2

౐ⷺ㩘㩨㩣㩎‫ోޓ‬㩒㩆㩨
/:575 
*':#)10#.*'#&5%4'9

౐ⷺ㩏㨹㩎㩆㨷
/575 
*':076

㩚㩀㩨㩁ਣᐔᐳ㊄
/575 
(.#69#5*'4

㩔㩨㩒ᐳ㊄
/575 
524+0)9#5*'4

࿶⌕┵ሶ
(8
.( 
%4+/210.7)


㪈㪅䍘䍎䍢䍼ᧃየ䈮㪲㪁㪁㪴䈱ઃ䈇䈢䍳䍤䍍䍢䈲ઍ⴫䈱ဳᑼ㪆䍘䍎䍢䍼䉕⴫␜䈚䈩䈇䉁䈜䇯
㪛㪦㪬㪙㪣㪜㩷㪘㪪㪫㪜㪩㪠㪪㪢㩷㪛㪜㪥㪦㪫㪜㪪㩷㪚㪦㪤㪤㪦㪥㪣㪰㩷㪬㪪㪜㪛㩷㪜㪨㪬㪠㪧㪤㪜㪥㪫㪅
㪉㪅㩿㪁㪈㪀ශ䈱䍗㪄䍪䍼䍷⚵ຠ䈲䇮㪌㫄㪃㪈㪇㫄䈱㐳䈘䈏䈅䉍䉁䈜䇯
㪌㫄㪃㪈㪇㫄㩷㪚㪘㪙㪣㪜㩷㪠㪪㩷㪪㪜㪣㪜㪚㪫㪠㪭㪜㩷㪦㪥㩷㪛㪜㪤㪘㪥㪛㪅

ဳᑼ㪆䍘䍎䍢䍼⇟ภ䈏䋲Ბ䈱႐ว䇮ਅᲑ䉋䉍਄Ბ䈮ઍ䉒䉎ㆊᷰᦼຠ䈪䈅䉍䇮䈬䈤䉌䈎䈏౉䈦䈩䈇䉁䈜䇯䇭䈭䈍䇮ຠ⾰䈲ᄌ䉒䉍䉁䈞䉖䇯 ဳᑼ㪆䍘䍎䍢䍼⇟ภ䈏䋲Ბ䈱႐ว䇮ਅᲑ䉋䉍਄Ბ䈮ઍ䉒䉎ㆊᷰᦼຠ䈪䈅䉍䇮䈬䈤䉌䈎䈏౉䈦䈩䈇䉁䈜䇯䇭䈭䈍䇮ຠ⾰䈲ᄌ䉒䉍䉁䈞䉖䇯
㪫㪮㪦㩷㪫㪰㪧㪜㪪㩷㪘㪥㪛㩷㪚㪦㪛㪜㪪㩷㪤㪘㪰㩷㪙㪜㩷㪣㪠㪪㪫㪜㪛㩷㪝㪦㪩㩷㪘㪥㩷㪠㪫㪜㪤㪅㩷㩷㪫㪟㪜㩷㪣㪦㪮㪜㪩㩷㪧㪩㪦㪛㪬㪚㪫㩷㪤㪘㪰㩷㪙㪜㩷㪪㪟㪠㪧㪧㪜㪛㩷㪠㪥㩷㪧㪣㪘㪚㪜㩷㪦㪝㩷㪫㪟㪜㩷㪬㪧㪧㪜㪩㩷 㪫㪮㪦㩷㪫㪰㪧㪜㪪㩷㪘㪥㪛㩷㪚㪦㪛㪜㪪㩷㪤㪘㪰㩷㪙㪜㩷㪣㪠㪪㪫㪜㪛㩷㪝㪦㪩㩷㪘㪥㩷㪠㪫㪜㪤㪅㩷㩷㪫㪟㪜㩷㪣㪦㪮㪜㪩㩷㪧㪩㪦㪛㪬㪚㪫㩷㪤㪘㪰㩷㪙㪜㩷㪪㪟㪠㪧㪧㪜㪛㩷㪠㪥㩷㪧㪣㪘㪚㪜㩷㪦㪝㩷㪫㪟㪜㩷㪬㪧㪧㪜㪩㩷
㪧㪩㪦㪛㪬㪚㪫㪅㩷㪨㪬㪘㪣㪠㪫㪰㩷㪠㪪㩷㪫㪟㪜㩷㪪㪘㪤㪜㪅 㪧㪩㪦㪛㪬㪚㪫㪅㩷㪨㪬㪘㪣㪠㪫㪰㩷㪠㪪㩷㪫㪟㪜㩷㪪㪘㪤㪜㪅
䋨⇛࿑䈱ኸᴺ䈲䇮ෳ⠨୯䈪䈜䇯㩷㩷㪛㪠㪤㪜㪥㪪㪠㪦㪥㪪㩷㪠㪥㩷㪛㪩㪘㪮㪠㪥㪞㩷㪝㪦㪩㩷㪩㪜㪝㪜㪩㪜㪥㪚㪜㩷㪦㪥㪣㪰㪅䋩 %6: 䋨⇛࿑䈱ኸᴺ䈲䇮ෳ⠨୯䈪䈜䇯㩷㩷㪛㪠㪤㪜㪥㪪㪠㪦㪥㪪㩷㪠㪥㩷㪛㪩㪘㪮㪠㪥㪞㩷㪝㪦㪩㩷㪩㪜㪝㪜㪩㪜㪥㪚㪜㩷㪦㪥㪣㪰㪅䋩 %1:
A-9 A-10
%1&'01  %1: 
6;2' (2  CODE NO. 007-008-780 10CT-X-9501 -0
TYPE FP10-02901 1/1
ઃዻຠ⴫
付属品表
#%%'5514+'5
⇟ภ ฬ‫ޓޓ‬⒓ ⇛‫ޓޓ‬࿑ ဳฬ㧛ⷙᩰ ᢙ㊂ ↪ㅜ㧛஻⠨ ACCESSORIES
01 0#/' 176.+0' &'5%4+26+105 3 6; 4'/#4-5 番 号 名  称 型名/規格 数量
略  図 用途/備考
-$⋥ઃߌ㊄ౕ ᠲ૞ㇱ↪ NO. NAME OUTLINE DESCRIPTIONS Q'TY REMARKS
(14%10641..70+6 メモリカード組品
 41*5 FP10-02902 制御部用
-$(+:0)2.#6'  FOR PROCESSOR UNIT
%1&'01 1 1
MEMORY CARD

CODE NO. 007-008-790
㩊㩨㩇㩎㩀㩔㩨㨺-$ 41*5 ᠲ૞ㇱ↪
(14%10641..70+6
 
&756%18'4-$ 
%1&'01 

㩄㩒㩂㩊㩆㨺㩣 ᠲ૞ㇱ↪
(14%10641..70+6
 41*5
&7//;(+./ 
%1&'01

㩚㩀㩨㩁ᐔᐳ㊄ ᠲ૞ㇱ↪
(14%10641..70+6
 /%4
(.#69#5*'4 
%1&'01

౐ⷺ㩏㨹㩎㩆㨷 ᠲ૞ㇱ↪
(14%10641..70+6
 /%$
*':076 
%1&'01

ࡃࡀᐳ㊄ ᠲ૞ㇱ↪
(14%10641..70+6
 /%9
524+0)9#5*'4 
%1&'01

㩅㩡ዊ㩒㩆㩨 ᠲ૞ㇱ↪
(14%10641..70+6
 /:%9/$0+
18#.*'#&5%4'9 
%1&'01

㨻㩖㩩㩈㨹㩎7+㩈㩛㩇$ ᠲ૞ㇱ↪
(14%10641..70+6
 /:575
*':$1.6 

9#5*'4*'#& %1&'01

㩄㩨㩛⿷ ᠲ૞ㇱ↪
(14%10641..70+6
 5,㩂㩥
47$$'4(''6 
%1&'01


10CT-X-9501

ဳᑼ㩄㨺㩎㩨⇟ภ߇㧞Ბߩ႐ว‫ޔ‬ਅᲑࠃࠅ਄Ბߦઍࠊࠆㆊᷰᦼຠߢ޽ࠅ‫ޔ߅ߥޓޕߔ߹޿ߡߞ౉߇߆ࠄߜߤޔ‬ຠ⾰ߪᄌࠊࠅ߹ߖࠎ‫ޕ‬ FURUNO ELECTRIC CO .,LTD.
6916;2'5#0&%1&'5/#;$'.+56'&(14#0+6'/6*'.19'4241&7%6/#;$'5*+22'&+02.#%'1(6*'722'4241&7%6 (略図の寸法は、参考値です。 DIMENSIONS IN DRAWING FOR REFERENCE ONLY.)
37#.+6;+56*'5#/'
㧔⇛࿑ߩኸᴺߪ‫ޔ‬ෳ⠨୯ߢߔ‫&ޓޕ‬+/'05+105+0&4#9+0)(144'('4'0%'10.;㧕

㧲㨁㧾㨁㧺㧻‫ޓ‬㧱㧸㧱㧯㨀㧾㧵㧯‫ޓ‬㧯㧻‫ޓ‬㧚㧘㧸㨀㧰 %1:
A-11 A-12
%1&'01  %6:   %1&'01  %1:  
6;2' 52 $1:012 6;2' 52 $1:012
5'652'4 5'652'4
5*+201 52#4'2#465.+56(14 75' 8'55'. 5*+201 52#4'2#465.+56(14 75' 8'55'.

&9)01 37#06+6; 4'/#4-5%1&'01 &9)01 37#06+6; 4'/#4-5%1&'01


+6'/ 0#/'1( 14 914-+0) +6'/ 0#/'1( 14 914-+0)
01 2#46 176.+0' 01 2#46 176.+0'
6;2'01 2'4 2'4 52#4' 6;2'01 2'4 2'4 52#4'
5'6 8'5 5'6 8'5

㩕㨷㨺㩇㩨 ㅍฃାⵝ⟎↪ 㩕㨷㨺㩇㩨 ()$8 ᜰ␜ⵝ⟎㧪೙ᓮㇱ↪


(1464#05%'+8'470+6 #2$( (14&+52.#;70+6
 ).#5567$'   (75'  
(75' ()$18 ()$1# 
#2$( #%8
 
㩕㨷㨺㩇㩨 ㅍฃାⵝ⟎↪
(1464#05%'+8'470+6
 ).#5567$' 
(75' ()$18
#2$(

㩕㨷㨺㩇㩨 ㅍฃାⵝ⟎↪
(1464#05%'+8'470+6
 ).#5567$' 
(75' ()$18#

㩕㨷㨺㩇㩨 ㅍฃାⵝ⟎↪
(1464#05%'+8'470+6
 ).#5567$' 
(75' ()/$8#
2$(


/(4 50#/' (74701'.'%64+%%1.6& &9)01 %6:  /(4 50#/' (74701'.'%64+%%1.6& &9)01 %1: 

㧔⇛࿑ߩኸᴺߪ‫ޔ‬ෳ⠨୯ߢߔ‫&ޓޕ‬+/'05+105+0&4#9+0)‫(ޓ‬144'('4'0%'10.;㧕 㧔⇛࿑ߩኸᴺߪ‫ޔ‬ෳ⠨୯ߢߔ‫&ޓޕ‬+/'05+105+0&4#9+0)‫(ޓ‬144'('4'0%'10.;㧕
ဳᑼ㩄㨺㩎㩨⇟ภ߇㧞Ბߩ႐ว‫ޔ‬ਅᲑࠃࠅ਄Ბߦઍࠊࠆㆊᷰᦼຠߢ޽ࠅ‫ޔ߅ߥޓޕߔ߹޿ߡߞ౉߇߆ࠄߜߤޔ‬ຠ ဳᑼ㩄㨺㩎㩨⇟ภ߇㧞Ბߩ႐ว‫ޔ‬ਅᲑࠃࠅ਄Ბߦઍࠊࠆㆊᷰᦼຠߢ޽ࠅ‫ޔ߅ߥޓޕߔ߹޿ߡߞ౉߇߆ࠄߜߤޔ‬ຠ⾰ߪ
⾰ߪᄌࠊࠅ߹ߖࠎ‫ޕ‬ ᄌࠊࠅ߹ߖࠎ‫ޕ‬
6916;2'5#0&%1&'5/#;$'.+56'&(14#0+6'/6*'.19'4241&7%6/#;$'5*+22'&+02.#%'1( 6916;2'5#0&%1&'5/#;$'.+56'&(14#0+6'/6*'.19'4241&7%6/#;$'5*+22'&+02.#%'1(6*'
6*'722'4241&7%637#.+6;+56*'5#/' 722'4241&7%637#.+6;+56*'5#/'
A-13 A-14
%1&'01  %1:  
%1&'01  %1: 
6;2' 52 $1:012
6;2' %2 
5'652'4
5*+201 52#4'2#465.+56(14 75' 8'55'.
Ꮏ੐᧚ᢱ⴫
+056#..#6+10/#6'4+#.5
⇟ภ ฬ‫ޓޓ‬⒓ ⇛‫ޓޓ‬࿑ ဳฬ㧛ⷙᩰ ᢙ㊂ ↪ㅜ㧛஻⠨
&9)01 37#06+6; 4'/#4-5%1&'01 01 0#/' 176.+0' &'5%4+26+105 3 6; 4'/#4-5
+6'/ 0#/'1( 14 914-+0) 㩄㩒㩂㩊
54%0㧕
01 2#46 176.+0'
6;2'01 2'4 2'4 52#4' 54%0#2
 
5'6 8'5 %100'%614
54%0
%1&'01
㩕㨷㨺㩇㩨 ()/$8# ਄ਅⵝ⟎
೙ᓮེ↪ 
2$( (14*#..70+6
 (75'   㩄㩒㩂㩊
54%0㧕
()/$#8   54%0#2
%100'%614
54%0 

%1&'01

㩄㩒㩂㩊
54%0㧕
 54%0#2 
%100'%614
54%0
%1&'01

㩄㩒㩂㩊
54%0
 54%0#2 
%100'%614
54%0
%1&'01

㩄㩒㩂㩊
54%0
 54%0#5 
%100'%614
54%0
%1&'01


/(4 50#/' (74701'.'%64+%%1.6& &9)01 %1: 


ဳᑼ㩄㨺㩎㩨⇟ภ߇㧞Ბߩ႐ว‫ޔ‬ਅᲑࠃࠅ਄Ბߦઍࠊࠆㆊᷰᦼຠߢ޽ࠅ‫ޔ߅ߥޓޕߔ߹޿ߡߞ౉߇߆ࠄߜߤޔ‬ຠ⾰ߪᄌࠊࠅ߹ߖࠎ‫ޕ‬
㧔⇛࿑ߩኸᴺߪ‫ޔ‬ෳ⠨୯ߢߔ‫&ޓޕ‬+/'05+105+0&4#9+0)‫(ޓ‬144'('4'0%'10.;㧕
ဳᑼ㩄㨺㩎㩨⇟ภ߇㧞Ბߩ႐ว‫ޔ‬ਅᲑࠃࠅ਄Ბߦઍࠊࠆㆊᷰᦼຠߢ޽ࠅ‫ޔ߅ߥޓޕߔ߹޿ߡߞ౉߇߆ࠄߜߤޔ‬ຠ⾰ߪᄌ 6916;2'5#0&%1&'5/#;$'.+56'&(14#0+6'/6*'.19'4241&7%6/#;$'5*+22'&+02.#%'1(6*'722'4241&7%6
ࠊࠅ߹ߖࠎ‫ޕ‬ 37#.+6;+56*'5#/'
㧔⇛࿑ߩኸᴺߪ‫ޔ‬ෳ⠨୯ߢߔ‫&ޓޕ‬+/'05+105+0&4#9+0)(144'('4'0%'10.;㧕
6916;2'5#0&%1&'5/#;$'.+56'&(14#0+6'/6*'.19'4241&7%6/#;$'5*+22'&+02.#%'1(6*'
722'4241&7%637#.+6;+56*'5#/'
㧲㨁㧾㨁㧺㧻‫ޓ‬㧱㧸㧱㧯㨀㧾㧵㧯‫ޓ‬㧯㧻‫ޓ‬㧚㧘㧸㨀㧰 %1:
D-1
D-2
D-3
D-4

Y. Hatai
D-5

Y. Hatai
D-6

Takahashi T.
Y. Hatai
D-7

Takahashi T.

Y. Hatai
D-8

Y. Hatai
D-9
D-10
This page is intentionally left blank.
1 2 3 4 5 6 S-1

送受信装置 FSV-301 制御部 FSV-3002/3002S 操作部 FSV-3001


10S2145,23m(*2) PROCESSOR UNIT *4
CN-C101 10S2144,13m(*2) TRANSCEIVER UNIT *3 *5 CONTROL UNIT
*1 CN-A103(108)
TB-C101 J1 10S2078,8m,φ17 *3 J1 CN-B102 CN-B101 J2 10S1258,φ18,MAX.100m J445 CN-A101 J411(421) 10S2076,10m(5m) XH-15P J1 CN-A201
220VAC TPYCY-4 1 U A ミドリ GRN A MSRXD-H A アカ 11 RED A TRXRXD-H CN1RXD-H A キ 4 YEL 3 CN1RXD-H
P P P
3φ,50/60Hz 2 V アカ RED B MSRXD-C B チャ 11 BRN B TRXRXD-C CN1RXD-C B クロ 4 BLK 4 CN1RXD-C
3 W アオ BLU C MSTXD-H C クロ 10 BLK C TRXTXD-H CN1TXD-H C ミドリ 3 GRN 1 CN1TXD-H
P P P
4 クロ BLK D MSTXD-C D シロ 10 WHT D TRXTXD-C CN1TXD-C D クロ 3 BLK 2 CN1TXD-C
A 5 ムラサキ PPL E UPLSW-H E ダイ 12 ORG E SIG_D0-H CN1TXA-H E アオ 5 BLU 5 CN1TXA-H
P P P
6 シロ WHT F UPLSW-C F チャ 12 BRN F SIG_D0-C CN1TXA-C F クロ 5 BLK 6 CN1TXA-C
7 チャ BRN H DEMGUP-H H アカ 19 RED H DEMGUP-H CN1TXB-H J チャ 6 BRN 7 CN1TXB-H
P P P
8 TT クロ BLK LL DEMGUP-C LL ダイ 19 ORG LL DEMGUP-C CN1TXB-C K クロ 6 BLK 8 CN1TXB-C
チャ BRN J MDLSW-H J クロ 9 BLK J SIG_D1-H CN1TYA-H L ムラサキ 7 PPL 9 CN1TYA-H
P P P
シロ WHT K MDLSW-C K ハイ 9 GRY K SIG_D1-C CN1TYA-C M クロ 7 BLK 10 CN1TYA-C
FSV-2431 *1 アオ BLU N DNLSW-H L キ 13 YEL L SIG_D2-H CN1TYB-H N アカ 8 RED 11 CN1TYB-H
IV-8sq. P P P
シロ WHT P DNLSW-C M チャ 13 BRN M SIG_D2-C CN1TYB-C P シロ 8 WHT 12 CN1TYB-C
キ YEL R DNCMD-H N クロ 8 BLK N SIG_D3-H GND JJ ミドリ 14 GRN 13 GND
上下装置 クロ BLK
P
S DNCMD-C P ムラサキ 8 PPL
P
P SIG_D3-C GND KK
P
アカ 14 RED 14 GND
HULL UNIT シロ WHT T UPCMD-H R ダイ 4 ORG R SIG_D4-H GND LL 15 GND
FSV-303/304 クロ BLK
P
U UPCMD-C S クロ 4 BLK
P
S SIG_D4-C XH-14P J2 CN-A202
ムラサキ PPL V DUPLSW-H T クロ 3 BLK T SIG_D5-H CN1PON-H R シロ 1 WHT 1 CN1PON-H
P P P
クロ BLK X DUPLSW-C U アカ 3 RED U SIG_D5-C CN1PON-C S クロ 1 BLK 2 CN1PON-C
アカ RED W TSFLG-H V キ 5 YEL V DUPLSW-H CN1POF-H T アカ 2 RED 3 CN1POF-H
P P P
シロ WHT Y TSFLG-C X クロ 5 BLK X DUPLSW-C CN1POF-C U クロ 2 BLK 4 CN1POF-C
ミドリ GRN Z MSROLL W チャ 2 BRN W AUDIO-H CN1AUDV1 V シロ 9 WHT 5 CN1AUDV1
P P P
クロ BLK AA MSR_GND Y クロ 2 BLK Y AUDIO-C CN1AUDV2 X ミドリ 9 GRN 6 CN1AUDV2
アカ RED BB MSPITCH Z ミドリ 6 GRN Z +12V CV1AUDV3 Z キ 10 YEL 7 CN1AUDV3
P P P
クロ BLK CC MSP_GND AA クロ 6 BLK AA GND CN1BRLV1 W シロ 10 WHT 8 CN1BRLV1
B ミドリ GRN JJ PWRHUL-H BB シールド SHIELD BB EXTKP-C CN1BRLV2 Y シロ 11 WHT 9 CN1BRLV2
P P
シロ WHT NN PWRHUL-C CC シンセン CORE CC EXTKP-H CN1BRLV3 CC アオ 11 BLU 10 CN1BRLV3
キ YEL PP PWRHUL-H DD ミドリ 14 GRN DD SIG_D6-H +12V PP ムラサキ 13 PPL 11 +12V
P P P
シロ WHT TT PWRHUL-C EE チャ 14 BRN EE SIG_D6-C GND MM シロ 13 WHT 13 GND
FF クロ 7 BLK FF SIG_D7-H +12V RR チャ 12 BRN 12 +12V
P P
TRX 10P6960 x10 HH アオ 7 BLU HH SIG_D7-C GND NN シロ 12 WHT 14 GND
*3 B201 JJ アオ 15 BLU JJ KP-H NC SS
10S2223,φ16 P
TT
P1~P2 KK チャ 15 BRN KK KP-C NC
MM チャ 18 BRN MM FS-H
10S2240, *3

B202
5/15m,φ16

P
P1~P2 NN シロ 18 WHT NN FS-C
接続箱
JUNCTION BOX B203 PP ムラサキ 16 PPL PP ENB-H
P
FSV-305 *2 P1~P2 RR チャ 16 BRN RR EMB-C
J1-20 J1-20 B204 SS チャ 17 BRN SS FSCLK-H
P
B201 B101 P1~P2 TT ハイ 17 GRY TT FECLK-C *4
B205 CN-A104(109)
B220 B120 P1~P2 J412(422) KEC-15P *1
DS1V-R 1
MONITOR CABLE 外部モニター
B206 EXT. MONITOR *1
アース銅板 *1 P1~P2 GND 6
送受波器 COPPER STRAP
B207 DS1V-G 2
TRANSDUCER 延長キット *2 P1~P2 GND 7
C EXTENSION KIT
B208 DS1V-B 3
P1~P2 GND 8
B209 DS1VSY 14
P1~P2 GND 5
B210 DS1HSY 13
P1~P2 GND 10

POWER
*1 TB-B101
100/110/115/ DPYCYS-2.5
1 AC_IN-H
220/230 VAC 2 AC_IN-C
1φ,50/60Hz
アース銅板
COPPER STRAP
WEA-1004 CN-A110
W=50,1.2m *1 NCS-253-P J16
DPYCY-1.5 3 AC_IN-H
2 AC_IN-C
1 SHIELD
D
*1
IV-8sq.

DRAWN TITLE
注記
NOTE 9/Jul/08 T.YAMASAKI FSV-30/30S
*1)造船所手配 CHECKED
*1: SHIPYARD SUPPLY. 9/Jul/08 T.TAKENO
名称 カラースキャニングソナー
*2)オプション。
*2: OPTION. APPROVED
*3)コネクタは工場にて取付済み。
*3: CONNECTOR PLUGS FITTED AT FACTORY. 18/Jul/08 R.Esumi 相互結線図
*4)( ):副表示部/副操作部用。 SCALE MASS NAME
*5)和文仕様では5/10mより選択。
*4: ( ): FOR SUB-MONITOR OR SUB-CONTROL. kg COLOR SCANNING SONAR
*5: 5m CABLE AVAILABLE FOR JAPANESE ONLY. DWG No.
C1323-C02- D 10-080-0101-0 INTERCONNECTION DIAGRAM
FURUNO ELECTRIC CO., LTD.
S-2
1 2 3
PCS-E68PM J14 PC IF MONITOR J1 KEC-15P
データ収録装置 1
外部モニター
MD-R 1
DATA RECORDER 制御部 EXTERNAL MONITOR
GND 6
メンテナンス専用 PROCESSOR UNIT MD-G 2
FOR MAINTENANCE
FSV-2402/2402S GND 7
MD-B 3
68
FSV-3002/3002S GND 8
*4 FSV-8402 MD-V-SYNC 14
A *2 SRCN6A16-10P J12 ES2/NET GND 5
魚探 I/F 02S8040,6m
ES I/F 1 ES2-SIG-IN MD-H-SYNC 13
VI-1100A 2 GND GND 10 *4
3 KP-DN-IN *3
4 NC NMEA1 J3 MJ-A6SPF *2
MJ-A6SPF0011/0012 航法装置
5 ES2-WL-IN NMEA1-TXD-H 1 5/10m,φ6 NAVIGATOR
6 GND NMEA1-TXD-C 2
7 GND NMEA1-RXD-H 3
8 KP-UP-IN NMEA1-RXD-C 4
9 NC SHIELD 6 *4
10 GND *3
*4 *2
*2 NMEA2/CIF2 J4 MJ-A6SPF
*2 SRCN6A21-10S *5 MJ-A6SPF0011/0012 航法装置
J13 EXT-KP NMEA2-TXD-H 1 5/10m,φ6
外部KP CO-0.2x5P NAVIGATOR
1 INTKP1 NMEA2-TXD-C 2
EXTERNAL KP
2 GND NMEA2-RXD-H 3
3 INTKP2 NMEA2-RXD-C 4
4 GND SHIELD 6 *4
5 INTKP3
6 GND CIF1 J5 SRCN6A13-5P *2
CO-0.2x2P
7 GND CIF-TXD-H 1
B 8 EXT-KP-IN-H CIF-TXD-C 2
P
潮流計
CURRENT INDICATOR
9 EXT-KP-IN-C CIF-RXD-H 3
P
*4 10 EXT-12VKP-IN CIF-RXD-C 4
SHIELD 5 *4
J15 CN-A105
1 AUX J6 17JE-13260-02(D1)
2 NC 1 パソコン
3 AUX-TXD 2 PC
メンテナンス専用
4 AUX-RXD 3
FOR MAINTENANCE
5 GND 7
6 NC 25 *4
7 *2
8 GYRO J7 SRCN6A16-10P *2
外部スピーカ CO-0.2x2P ADコンバータ
EXTERNAL SPEAKER CN-A106 AD-DATA-H 2
2.8m P AD CONVERTER
SEM-21Q 1 SP-AUDIO AD-DATA-C 3 AD-100
2 GND AD-CLK-H 6
P
AD-CLK-C 7
NJC-203PM J17 CS-120A SHIELD 10 *4
CS-120A 1 +24VDC *2
2 0V LOG J8 SRCN6A13-3P *1
C 3 SHIELD LOG 1
DPYC-1.5 スピードログ
SPEED LOG
GND 2
SRCN2A21-16S J11 FNZ-AUX NC 3 *4
1 SONDE_3 予備 *2
2 GND ES1 J9 SRCN6A16-7P *2
RESERVE 02S8040,6m 魚探I/F
3 SONDE_4 ES1-SIG-IN 1
ES I/F
4 GND GND 2
5 VI-1100A
SONDE_5 ES1-KP-IN 3
注記 6 GND NC 4
*1)造船所手配 7 SONDE_6 ES1-WL-IN 5
8 GND SHIELD 6
*2)オプション。
9 SONDE_7 GND 7 *4
*3)コネクタは工場にて取付済み。 10 GND *2
*4)コネクタクランプでアースに落とす。 11 SONDE_8 FNZ J10 SRCN6A21-10P *1
*5)IFES基板S2 #8にて選択。 CO-0.2x5P ネットゾンデ
12 GND SONDE_0 1
工場出荷時はCIF(OFF)。 NET SONDE
13 SONDE_9 GND 2
14 GND SONDE_1 3
16 GND GND 4
NOTE SONDE_2 5
GND 6
D *1: SHIPYARD SUPPLY. SONDE_KP 7
*2: OPTION. GND 8
*3: CONNECTOR PLAG FITTED AT FACTORY. SONDE_WL 9
GND 10 *4
*4: GROUND THRU CONNECTOR CLAMP.
*5: SELECT CIF OR NMEA AT S2 #8 ON
IFES BOARD. DEFAULT IS CIF (OFF). CO-0.2x2P: CO-SPEVV-SB-C 0.2x2P,φ10.5
CO-0.2x5P: CO-SPEVV-SB-C 0.2x5P,φ13.5

DRAWN TITLE
Dec. 26 '06 E.MIYOSI FSV-2402/2402S/3002/3002S/8402
CHECKED 名称
TAKAHASHI. T 制御部外部信号接続
APPROVED
Y. Hatai FSV-24/24S/30/30S/84/84L 相互結線図
SCALE MASS NAME
kg PROCESSOR UNIT EXTERNAL INTERFACE
DWG.No.
C1318-C03- N INTERCONNECTION DIAGRAM

You might also like