Datasheet - NZMN3-AE630: Part No. Article No. Catalog No
Datasheet - NZMN3-AE630: Part No. Article No. Catalog No
Datasheet - NZMN3-AE630: Part No. Article No. Catalog No
model=259115
Datasheet - NZMN3-AE630
Part no.
Article no.
Catalog No.
Delivery program
Product range
Protective function
Standard/Approval
Installation type
Release system
Construction size
Description
Number of poles
Standard equipment
Switching capacity
400/415 V 50 Hz Icu
Rated current = rated uninterrupted current
Rated current = rated uninterrupted current In = I u
Setting range
Overload trip
Ir
Short-circuit releases
Non-delayed Ii = I n x …
Short-circuit releases Irm
Technical data
General
Standards
Protection against direct contact
Climatic proofing
Ambient temperature
Ambient temperature, storage
Operation
IEC 60068-2-27
Safe isolation to EN 61140
Between auxiliary contacts and main contacts
between the auxiliary contacts
Weight
Mounting position
Direction of incoming supply
Degree of protection
Device
Enclosures
Terminations
Other technical data (sheet catalogue)
Circuit-breakers
Rated current = rated uninterrupted current In = I u
Rated surge voltage invariability Uimp
Main contacts
Auxiliary contacts
Rated operational voltage Ue
Overvoltage category/pollution degree
Rated insulation voltage Ui
Use in unearthed supply systems
Switching capacity
Rated short-circuit making capacity Icm
240 V Icm
400/415 V Icm
440 V 50/60 Hz Icm
525 V 50/60 Hz Icm
690 V 50/60 H Ic
Rated short-circuit breaking capacity I cn Icn
Icu to IEC/EN 60947 test cycle O-t-CO Icu
240 V 50/60 Hz Icu
400/415 V 50/60 Hz Icu
440 V 50/60 Hz Icu
525 V 50/60 Hz Icu
690 V 50/60 Hz Icu
Ics to IEC/EN 60947 test cycle O-t-CO-t-CO Ics
240 V 50/60 Hz Ics
400/415 V 50/60 Hz Ics
440 V 50/60 Hz Ics
525 V 50/60 Hz Ics
690 V 50/60 Hz Ics
Optional accessories
Round copper conductor
Box terminal
Solid
Stranded
Tunnel terminal
Solid
Stranded
1-hole
Double hole fitting
Bolt terminal and rear-side connection
Direct on the switch
Solid
Stranded
Connection width extension
Connection width extension
Al circular conductor
Tunnel terminal
Solid
Stranded
Stranded
Double hole
Solid
Stranded
Cu strip (number of segments x width x segment thickness)
Box terminal
min.
max.
Bolt terminal and rear-side connection
Flat copper strip, with holes min.
Flat copper strip, with holes max.
Connection width extension
Copper busbar (width x thickness) mm
Bolt terminal and rear-side connection
Screw connection
Direct on the switch
min.
max.
Connection width extension
Connection width extension max.
Control cables
Characteristics
1230DIA-66
1230DIA-41
Let-through current
1230DIA-44
Let-through energy
Dimensions
123X330
① Blow out area, minimum clearance to adjacent parts
② Minimum clearance to adjacent parts
123X553
03.02.2021 10:59
NZMN3-AE630
259115
259115
1230PIC-706
Circuit-breaker
System and cable protection
IEC
Fixed
Electronic release
NZM3
R.m.s. value measurement and “thermal memory”
3 pole
Screw connection
kA 50
A 630
A 315 - 630
2-8
A 1260 - 5040
IEC/EN 60947
Finger and back of hand proof to VDE 0106 Part 100
Damp heat, constant, to IEC 60068-2-78
Damp heat, cyclic, to IEC 60068-2-30
°C - 40 - + 70
°C -25 - +70
g 20 (half-sinusoidal shock 20 ms)
V AC 500
V AC 300
kg 6.34
Vertical and 90° in all directions
123I692
123I692
as required
A 630
V 8000
V 6000
V AC 690
III/3
V 1000
V ≦ 690
kA 187
kA 105
kA 74
kA 53
kA 40
kA
kA 85
kA 50
kA 35
kA 25
kA 20
kA
kA 85
kA 50
kA 35
kA 13
kA 5
installation location exceed the switching capacity of the circuit-breaker.
kA 3.3
kA 3.3
A
15000
5000
5000
3000
2000
2000
2000
Ops/h 60
ms < 10
Screw connection
Box terminal
Tunnel terminal
connection on rear
mm2 2 x 16
1 x (35 - 240)
mm2 2 x (25-120)
mm2 1 x 16
1 x 16
mm2 2 x 16
1 x (25 - 240)
mm2 2 x (25 - 240)
mm2
mm2 2 x 300
mm2 1 x 16
1 x 16
mm2 2 x (10 - 16)
1 x (25 - 120)
mm2 2 x (25 - 120)
mm 6 x 16 x 0.8
10 x 24 x 1.0
+ 5 x 24 x 1.0
mm (2 x) 8 x 24 x 1.0
mm 6 x 16 x 0.8
mm 10 x 32 x 1.0 + 5 x 32 x 1.0
mm (2 x) 10 x 50 x 1.0
M10
mm 20 x 5
30 x 10
mm + 30 x 5
mm
mm 2 x (10 x 50)
1 x (0.75 - 2.5)
mm2 2 x (0.75 - 1.5)
A 630
W 119.07
°C -25
°C 70
A 630
V 690 - 690
kA 55
A 315 - 630
A 0-0
A 1260 - 5040
No
Screw connection
Built-in device fixed built-in technique
No
No
0
0
0
No
No
3
Front side
Rocker lever
Yes
No
Yes
IP20
With XFI earth-fault release:
- NZM1, N1, NZM2, N2: vertical and 90° in all directions
with plug-in unit
- NZM1, N1, NZM2, N2: vertical, 90° right/left
with withdrawable unit:
- NZM3, N3: vertical, 90° right/left
- NZM4, N4: vertical
with remote operator:
- NZM2, N(S)2, NZM3, N(S)3, NZM4, N(S)4: vertical and 90° in all directions