Aqualamp User Manual
Aqualamp User Manual
Aqua Lamp is powered by a Magnesium Fuel Cell and includes a pre-installed magnesium power bar
that when immersed in salt water, creates electricity. At about 100 hours (you can stop and start the
process anytime) the magnesium bar dissolves, stopping power generation. To reuse, simply replace
the used bar with a new one and add more salt water! The magnesium power bar and residual salt
water is safe, non-toxic and Earth friendly.
FUNCTIONAL DESCRIPTION
OPERATION
NOTE
Before opening the Drainage Port, make sure there is no residual salt water in inside. If residual
water exists, first position the lantern horizontally with the Power Bar Knob facing up before remov-
ing so the water does not spill out. (Step 3, Fig.6 and 7).
OPERATION
2. Adding Salt and Water
(A) Remove the Feeder Portal Lid and Base Cap from the lantern.
Pour (2) scoops of salt (equal to 2 teaspoons / 10ml) into the
Feeder Portal using the included Salt Measuring Spoon (Fig. 4).
Small grain, common table salt works best. Do not use “Lite
Salt”.
(B) Using the Base Cap as a measuring device, pour 1-1/2 capfuls
of water (equal to 6 oz. / 180ml) into the Feeder Portal, ensuring
that all of the salt is washed down the funnel (Fig. 5).
Replace the Feeder Portal Lid and Base Cap, ensuring they are
properly threaded and snug. “Swirl” the lantern several times to
mix the salt water in the Fuel Cell Chamber.
Fig.5
(C) Press the On/Off button on the front of the lantern to turn on the
LED light. Fig.4
(B) Rotate the lantern so the Drainage Port faces down (Fig.7)
and allow the water to completely drain. Using fresh water,
thoroughly rinse the inside of the lantern several times to
remove all residual salt water.
Allow the lantern and power bar to dry, then re-install the
power bar and store for future use. Fig.7
IMPORTANT OPERATIONAL INFORMATION - PLEASE READ
1. Maintaining Optimal Operational Performance
(A) With a new power bar installed, you can run the light consistently for about 100 hours before
needing to replace the bar as long as you change the salt water about every 24 hours.
Follow the same cleaning instructions as Step 3 (A & B). Add fresh water and salt and re-install
the power bar to continue using the light. Remember - even though the light is switched off,
power is still being generated and the power bar is slowly dissolving.
(B) When not using the light, it is best to remove the salt water following Step 3 (A & B). Allow the
power bar to dry before replacing and storing for future use.
(C) Clean after each use and before storing following Step 3 (B). If salt water is left in the Fuel Cell
Chamber more than one week without replacement, power and light may continue to generate
but the salt water and magnesium solution will solidify and could damage the lantern. If this
occurs, rinse thoroughly and agitate but do not use any implements to remove the solids. This
could damage the Fuel Cell Chamber.
(D) Wipe away any salt water and dissolved magnesium solution that may come in contact with
metal or painted surfaces.
! CAUTION
The residual salt water is non-toxic but drinking it may cause diarrhea. If accidentally
swallowed, dilute by drinking plenty of fluids. Keep away from children. Do not expose
magnesium bar to an open flame.
LIMITED WARRANTY
This product is warranted against manufacturing defects and /or workmanship. Our liability for
defects in this product shall not exceed the purchase price and will not extend to any damages
resulting from use of this product in any way other than those explained in this manual.
TM
Eco-Emergency Lantern
Eco-Emergency Lantern