Body Flanges On Shells: (Name and Address of Manufacturer)
Body Flanges On Shells: (Name and Address of Manufacturer)
Body Flanges On Shells: (Name and Address of Manufacturer)
(Alternative Form for Single Chamber, Completely Shop or Field Fabricated Vessels Only)
As Required by the Provisions of the ASME Boiler and Pressure Vessel Code Rules, Section VIII, Division 1 Page 1 of 2
1. Manufactured and certified by Westermeyer Industries, Inc., Mueller Industries, 1441 State Route 100, Bluffs, Illinois, 62621
(Name and address of Manufacturer)
2. Manufactured for Mayekawa USA Tennessee Plant, 130 Smart Park Dr, Lebanon, Tennessee, 37090
(Name and address of Purchaser)
3. Location of Installation Unknown
(Name and address)
Location (Top, Bottom, Minimum Corrosion Crown Radius Knuckle Radius Elliptical Ratio Conical Apex Hemispherical Flat Side to Pressure (Convex or
Ends) Thickness Allowance Angle Radius Diameter Concave)
(a) END .353" 0 N/A N/A 2:1 N/A N/A N/A Concave
(b) END .353" 0 N/A N/A 2:1 N/A N/A N/A Concave
Min Hub
Type ID OD Flange Thk Material How Attached
Bolting
Thk
Location Num & Size Bolting Material
Washer (OD,
Washer Material
ID, thk)
(a) N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A
9. MAWP 350 psi N/A at max. temp. 300 °F N/A
(Internal) (External) (Internal) (External)
Min. design metal temp. -20 °F at 300 psi . Hydro, pneu., or comb. test pressure PNEU at 385 psi .
No Lugs Legs Other Saddle/Angle/Channel Bracket (6), (1) Attached Shell, Welded
nameplate bracket
11. Supports: Skirt N/A N/A
(Yes or no) (Number) (Number) (Describe) (Where and how)
12. Remarks: Manufacturer's Partial Data Reports properly identified and signed by Commissioned Inspectors, have been furnished for the following items of the report:
N/A
(Name of part, item number, Manufacturer's name and identifying stamp)
Impact test exempt per UCS-66(b). For non-corrosive service. Constructed under the provisions of
UG-90(c)(2).(1) 4" Class 300 Blind Flange SA-105, (2) 28x5/24" Re-pad SA-516 GR 70
CRN:R0235.5/W2925.21367890YTN
FORM U-1A Page 2 of 2
Manufactured by Westermeyer Industries, Inc., Mueller Industries, 1441 State Route 100, Bluffs, Illinois, 62621
Manufacturer's Serial No. U111337 CRN See remarks National Board No. 111337
Vessel constructed by Westermeyer Industries, Inc., Mueller Industries at 1441 State Route 100, Bluffs, Illinois, 62621
I, the undersigned, holding a valid commission issued by The National Board of Boiler and Pressure Vessel Inspectors and employed by
OneCIS Insurance Company, of Lynn, MA
have inspected the component described in this Manufacturer's Data Report on June 27, 2019 ,
and state that, to the best of my knowledge and belief, the Manufacturer has constructed this pressure vessel in accordance with ASME BOILER
AND PRESSURE VESSEL CODE, Section VIII, Division 1. By signing this certificate neither the Inspector nor his/her employer makes any
warranty, expressed or implied, concerning the pressure vessel described in this Manufacturer's Data Report. Furthermore, neither the Inspector
nor his/her employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with
this inspection.
1. Manufactured and certified by Westermeyer Industries, Inc., Mueller Industries, 1441 State Route 100, Bluffs, Illinois, 62621
(Name and address of Manufacturer)
2. Manufactured for Mayekawa USA Tennessee Plant, 130 Smart Park Dr, Lebanon, Tennessee, 37090
(Name and address of Purchaser)