Battery Technical Spec

Download as pdf or txt
Download as pdf or txt
You are on page 1of 4

grid | power V L

Series OPzS/power.bloc OPzS


Similar to the illustration

Vented lead-acid battery

www.hoppecke.com

1
grid | power V L Series OPzS

Typical applications: Your benefits:



Telecommunications Very high expected service life –
- Mobile phone stations due to optimized low-antimony selenium alloy
- BTS-stations Excellent cycle stability – due to tubular plate design
- Off-grid/on-grid solutions
Maximum compatibility – design according to DIN 40736-1
Power Supply
Higher short-circuit safety even during the installation –

Security lighting based on HOPPECKE system connectors
Extremely extended water refill intervals up to maintenance-
free – optional use of AquaGen® recombination system
minimizes emission of gas and aerosols1

grid | power V L Series power.bloc OPzS

Typical applications: Your benefits:



Telecommunications High expected service life –
- Mobile phone stations due to optimized low-antimony selenium alloy
- BTS-stations Excellent cycle stability – due to tubular plate design
- Off-grid/on-grid solutions
Maximum compatibility – dimensions according to DIN 40737-3
Power Supply systems
Easy assembly and installation –

Security lighting battery lid with integral handle
Higher short-circuit safety even during the installation –
based on HOPPECKE system connectors
Extremely extended water refill intervals up to maintenance-
free – optional use of AquaGen® recombination system
minimizes emission of gas and aerosols1

grid | power V L grid | power V L


Series OPzS Series power.bloc OpzS

1
Similar to sealed lead-acid batteries

2
Capacities dimensions and weights

DIN C10/1.80 V C5/1.77 V C3/1.75 V C1/1.67 V max.* Weight Weight electrolyte max.* Length L max.* Width W max.* Height H
Series OPzS Fig.
Type Ah Ah Ah Ah kg kg (1.24 kg/l) mm mm mm
grid | power V L 2-215 4 OPzS 200 213 182 161 118 17.3 4.5 105 208 420 A
grid | power V L 2-270 5 OPzS 250 266 227 201 147 21.0 5.6 126 208 420 A
grid | power V L 2-325 6 OPzS 300 320 273 241 177 24.9 6.7 147 208 420 A
grid | power V L 2-390 5 OPzS 350 390 345 303 217 29.3 8.5 126 208 535 A
grid | power V L 2-470 6 OPzS 420 468 414 363 261 34.4 10.1 147 208 535 A
grid | power V L 2-550 7 OPzS 490 546 483 426 304 39.5 11.7 168 208 535 A
grid | power V L 2-690 6 OPzS 600 686 590 510 353 46.1 13.3 147 208 710 A
grid | power V L 2-805 7 OPzS 700 801 691 596 411 59.1 16.7 215 193 710 B
grid | power V L 2-920 8 OPzS 800 915 790 681 470 63.1 17.3 215 193 710 B
grid | power V L 2-1035 9 OPzS 900 1026 887 767 529 72.4 20.5 215 235 710 B
grid | power V L 2-1150 10 OPzS 1000 1140 985 852 588 76.4 21.1 215 235 710 B
grid | power V L 2-1265 11 OPzS 1100 1256 1086 938 647 86.6 25.2 215 277 710 B
grid | power V L 2-1380 12 OPzS 1200 1370 1185 1023 706 90.6 25.8 215 277 710 B
grid | power V L 2-1610 12 OPzS 1500 1610 1400 1197 784 110.4 32.7 215 277 855 B
grid | power V L 2-1880 14 OPzS 1750 1881 1632 1397 914 142.3 46.2 215 400 815 C
grid | power V L 2-2015 15 OPzS 1875 2016 1748 1496 980 146.6 46.7 215 400 815 C
grid | power V L 2-2150 16 OPzS 2000 2150 1865 1596 1045 150.9 45.9 215 400 815 C
grid | power V L 2-2420 18 OPzS 2250 2412 2097 1796 1176 179.1 56.4 215 490 815 D
grid | power V L 2-2555 19 OPzS 2375 2546 2213 1895 1242 182.9 55.6 215 490 815 D
grid | power V L 2-2690 20 OPzS 2500 2680 2330 1995 1307 187.3 55.7 215 490 815 D
grid | power V L 2-2960 22 OPzS 2750 2952 2562 2195 1437 212.5 67.0 215 580 815 D
grid | power V L 2-3095 23 OPzS 2875 3086 2678 2294 1503 216.8 65.9 215 580 815 D
grid | power V L 2-3230 24 OPzS 3000 3220 2795 2394 1568 221.2 66.4 215 580 815 D
grid | power V L 2-3500 26 OPzS 3250 3488 3028 2594 1699 229.6 65.4 215 580 815 D
C10, C5, C3 and C1 = Capacity at 10 h, 5 h, 3 h and 1 h discharge * according to DIN 40736-1 data to be understood as maximum values

DIN C10/1.80 V C5/1.77 V C3/1.75 V C1/1.67 V max.* Weight Weight electrolyte max.* Length L max.* Width W max.* Height H
Series power.bloc OPzS Fig.
Type Ah Ah Ah Ah kg kg (1.24 kg/l) mm mm mm
grid | power V L 12-50 12 V 1 power.bloc OPzS 50 50 44 39 28 37.0 max.
max. 15.0 272 205 383 A
grid | power V L 12-100 12 V 2 power.bloc OPzS 100 101 88 78 57 48.0 min.
13.0 min. 272 205 383 A
grid | power V L 12-150 12 V 3 power.bloc OPzS 150 151 132 117 85 67.0 18.0 380 205 383 A
grid | power VL 6-200 6 V 4 power.bloc OPzS 200 202 176 155 114 47.0 13.0 272 205 383 B
grid | power 6-250 6 V 5 power.bloc OPzS 250 252 220 194 142 60.0 20.0 380 205 383 B
max.

VL Pb Pb
max.
min.

grid | power
max.

VL 6-300 6 V 6 power.bloc OPzS 300 302 264 233 171 67.0 18.0 380 min.
205 383 B
Low
Antimony

Low

C10, C5, C3 and C1 = Capacity at 10 h, 5 h, 3 h and 1 h discharge


Antimony

+ +
* according to DIN 40737-3 data to be unterstood as maximum values
+ + Low
Antimony

Pb Pb
Pb

Fig. A Series OPzS Fig. B Series OPzS + Fig. C


+ Series+ OPzS + + + Fig.
+ A +Series power.bloc OPzS
Low
Antimony

+ + + + + +
+ + + + + +
+ +
max. max.
max. max.

+ + + +
W

min. min.
W

German Quality Standard


min. min.

+ + + +
German Quality Standard

+
+
German Quality Standard

Pb
W

Low Low
Antimony Antimony
Low

Pb Pb
Antimony
Low Low
Antimony Antimony

Pb Pb
Low
Antimony

L + + L Pb
W

Low
Antimony

+ + + +
+ +
grid | power V L 2-215 - grid | power V L 2-805 -
+
max.

grid | power V L 2-690 grid | power V L 2-1610


min.
L
L grid | power V L 12-50 -
max.
max.

min.
min.

Fig. D Series OPzS grid | power V L 2-1880- grid | power V L 12-150


max.

Pb grid | power V L 2-2150


min.
Low
Antimony

Pb
Low
Antimony

Pb
German Quality Standard

Fig. B Series power.bloc OPzS


German
GermanQuality Standard
Quality Standard
Low
Antimony

German
German Quality
Quality Standard
Standard
+
German Quality Standard
German
+
German Quality
Quality
GermanStandard
Standard
Quality Standard
German Quality Standard
German Quality Standard
Pb
Pb
Low
Pb
+ +
Antimony

max. max.

Pb
max. max.

Pb+ +
W

Low
Low
Low Antimony
Antimony
Antimony

Pb
Low
Antimony

Pb
Low

min. min.
Antimony
Low
Low
Antimony
Antimony

min. min.

Pb
Low German Quality Standard
Antimony
Low

Pb
Low
Antimony
Antimony
H

Low
Antimony

German Quality Standard

+ +
German Quality Standard

+ + + +
Pb
H

Low Low
Antimony Antimony

Pb Pb
Low Low
Antimony Antimony
Low
Antimony

Low
Antimony

Pb Pb
W

Pb
Low
Antimony

+ + + +

+ + L + + L

grid | power V L 2-2420 - grid | power V L 6-200 -


grid | power V L 2-3500 grid | power V L 6-300

Design life: up to 20 years Design life: up to 18 years


Optimal environmental compatibility – closed loop for Optimal environmental compatibility – closed loop for
recovery of materials in an accredited recycling system recovery of materials in an accredited recycling system

3
D - 59929 Brilon
Bontkirchener Str. 1

www.hoppecke.com
Tel: +49 (0) 2963 61-374
Fax: +49 (0) 2963 61-270
HOPPECKE Batterien GmbH & Co. KG

E-Mail: [email protected]

4
01/2018 EN grid | power V L All details in this brochure are based on state-of-the-art technology. Our products are subject to constant development. We therefore reserve the right to make changes.

You might also like