Civil Guruji: FRAME 2A (250X300) FRAME 6 (250X300)

1. The drawing shows reinforcement details and should be read with relevant architectural drawings and specifications. 2. All dimensions are in millimeters unless otherwise stated. 3. Only written dimensions on the drawing should be followed, it is not to be scaled.

Uploaded by

Shankar Dev Gour
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
308 views1 page

Civil Guruji: FRAME 2A (250X300) FRAME 6 (250X300)

1. The drawing shows reinforcement details and should be read with relevant architectural drawings and specifications. 2. All dimensions are in millimeters unless otherwise stated. 3. Only written dimensions on the drawing should be followed, it is not to be scaled.

Uploaded by

Shankar Dev Gour
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 1

1.

THE DRAWING SHALL BE READ IN


CONJUNCTION WITH RELEVANT ARCH.
8-12#(4+4) 2-12# 6-12#(3+3) 6-12#(3+3) 2-12# 2-12# DRAWINGS AND SPECIFICATIONS.

2. ALL DIMENSIONS ARE IN MILLIMETER

300

300
300
300

300

300
8# 2LG. ST. 8# 2LG. ST. 8# 2LG. ST. 8# 2LG. ST. 8# 2LG. ST. 8# 2LG. ST.
@120C/C. @120C/C. @120C/C. @120C/C. @120C/C. UNLESS OTHERWISE STATED.
@120C/C.

3-12# 3-12# 3-12# 3-12# 5-12#(3+2)


250 250 250 250
3-12#
250 3. ONLY WRTTEN DIMENSIONS ARE TO BE
250
FOLLOWED & THE DRAWIHGS ARE NOT
SEC. ON 1-1 SEC. ON 2-2 SEC. ON 3-3 SEC. ON 4-4 SEC. ON 5-5 SEC. ON 11-11 TO BE SCALLED
4. DEVIATIONS IF ANY TO THE
STRUCTURAL
4-12# 8-12#(4+4)
4-12# 7-12#(4+3) 2-12# DRA`WINGS SHALL BE BROUGHT TO THE
NOTICE OF THE STRUCTURAL

300
CONSULTANT BEFORE EXECUTION.

300
300
8# 2LG. ST. 8# 2LG. ST.
300

300
8# 2LG. ST. 8# 2LG. ST. 8# 2LG. ST.
@120C/C. @120C/C. @120C/C.
@120C/C. @120C/C.
3-12# 5-12#(3+2) 5. GRADE OF R.C.C SHALL BE M-25
3-12# 3-12# 3-12#
250 250 250
250 250
SEC. ON 9-9 SEC. ON 10-10 6. REINFORCEMENT SHALL BE HIGH
SEC. ON 6-6 SEC. ON 7-7 SEC. ON 8-8
STRENGTH DEFORMED BAR OF GRADE
Fe415/ Fe:500 CONFORMING TO
IS:1786-1985.

7. CLEAR COVER TO MAIN REINFORCEMENT


SHALL BE AS FOLLOWS .
FOOTINGS = 50 mm
COLUMNS = 40mm

I
FLOOR/ROOF BEAMS = 25mm
SLABS = 20mm

J
8. FOUNDATION HAS BEEN DESIGNED
3500
CONSIDERING SOIL BEARING

U
1165 1165 1275 CAPACITY AS 15.00 T/Sqm .
425 425
8-12#(4+4) 2-12# 8-12#(4+4)
10 11 10 4-12#(2+2) 2-12# 4-12#(2+2) 9. FINISHED GROUND LEVEL HAS BEEN

R
300 CONSIDERED ± 0 MM/ FEET.

300

300
10 5-12# (3+2) 11 10
10.IT IS DESIGNED FOR S+1 STRUCTURE.

U
8# 2LG. ST.
@120C/C 2-12#
8# 2LG. ST.
THROUGH OUT. 11. UNLESS NOTED OTHERWISE THE MIN.
@120C/C
THROUGH OUT. LAP/ DEVELOPMENT LENGTH OF BARS

G
FRAME 2A (250X300) FRAME 6 (250X300) OF DIAMETER 'D' SHALL BE AS
FOLLOWS.
CONCRETE DEFORMED BARS
GRADE TENSION COMPRESSION

L
M-25 50 D 38 D

I
4400 2650 CIVIL GURUJI
1465 1465 885 885
Head Office Bhiali, Chhattisgarh

V
7-12#(4+3) 2-12# 7-12#(4+3) 3-12# 2-12# 3-12#
7 8 7

I
300

SINGNATURE

300

300
SINGNATURE
7 8 3-12# 7
2-12#

C
8# 2LG. ST. 8# 2LG. ST.
@120C/C @120C/C SINGNATURE OF (CREDA)
THROUGH OUT. PROJECT CONSULTANT:-
THROUGH OUT.
FRAME 7 (250X300) CIVIL GURUJI
FRAME 4A (250X300)
ARCHITECT:- SINGNATURE OF ARCHITECT:-
Corporate Trainer (Design)

STRUCTURAL ENGINEER:
4400
1465 1465
4-12# 2-12# 4-12# PROJECT TITLE:-
9 8 9
PROPOSED SAINIKA SCHOOL COMPLEX
300

IN PHASE-II & PHASE-III


9 8 3-12# 9
8# 2LG. ST. DRAWING TITLE:-
@120C/C
THROUGH OUT.

FRAME 5A (250X300) SCALE DATE DRN. BY. DRG. NO. REV.-2

N.T.S. --.--.---- SS/1BHK/ST/02