Quick Start Guide Quick Start Guide

BioEntry™ Smart/Pass BioEntry™ Smart/Pass

A BioEntry™ Smart or Pass unit includes: The BioEntry is connected to other devices of the security system through the pigtail cable at the rear side.
y BioEntry™ Smart or Pass with pigtail connection cable Wire color Signal Description
y Stereo plug to DB-9 cable
y Star wrench Shield (naked wire) EARTH GND Ground Earth
y 2 ferrite cores Blue with yellow tracer Reserved
y Quick Start Guide
y Mounting Template Black with white tracer IN0 TTL IN 0
y CD containing BioEntry™ Admin Software, Installation Guide, Operation manual, etc. If not, Black IN1 TTL IN 1
you can download same software and documents at http://www.supremainc.com
Brown with white tracer OUT0 TTL OUT 0

Additional items to be required for Setup Brown OUT1 TTL OUT 1


y DC Power supply rated at 9~24V @ 500mA Red with white tracer IO_GND GND, for IO signals
y BioEntry™ Admin Software runs at Windows 98, ME, 2000 or XP
Red DCO_STRB Data/Clock Output, Strobe
y Mifare smart card in case of BioEntry™ Smart
y An access controller with Wiegand input port or Data/Clock input port Orange with white tracer WO_GND Wiegand Output, GND
Orange WO_VREF Wiegand Output, VREF
Setting up the BioEntry™ Smart/Pass Yellow with red tracer WO_D0 Wiegand Output, Data 0 or Data/Clock Output, Card Present
y Carefully read this Quick Start Guide, Installation Guide, and Operation Manual.
y Check all wiring and device configuration in Installation Guide. Yellow WO_D1 Wiegand Output, Data 1 or Data/Clock Output, Data
Green with white tracer WI_D0 Wiegand Input, Data 0
Warning: Care should be taken identifying the wires. Improper wiring may render permanent
damage to the BioEntry™ or personal injury. Carefully please read the section of Green WI_D1 Wiegand Input, Data 1
“Connecting Wires” in Installation Guide. Blue with white tracer COM_GND Comm. GND (for RS-232C)
Blue WI_GND Wiegand Input GND
Warning: To prevent ground loops and avoid communication problems, connect cable shield
to earth GND at only one point. Violet with white tracer RX2 Receive data, RS-232C level
Violet TX2 Transmit data, RS-232C level
y Check for the correct supply voltage rated at 9~24V @ 500mA before powering up the Gray with red tracer RX+ RX+, RS-485 level
BioEntry™ Smart or Pass through the pigtail.
y Install the BioEntry™ Admin Software on PC or Laptop by running BioAdmin.exe in CD. By Gray RX- RX-, RS-485 level
using this software, you will be able to do template management of respective BioEntry, White with red tracer TX+ TX+, RS-485 level
properly adjust relevant parameters, enroll or delete templates, etc.
y Configure COM port, Admin Password and Site-Key - only for BioEntry™ Smart – in White TX- TX-, RS-485 level
preference window of the BioEntry™ Admin Software. Please read the preference section in Green with yellow tracer POW_GND Power GND
Operation Manual
Red with yellow tracer POW+ Power Input
For more information, please contact Suprema and its local representatives in your country.
Table > BioEntry wire colors
Contact Information:
Warning: Care should be taken identifying the wires. Improper wiring may render permanent
Suprema Inc. (http://www.supremainc.com) damage to the device or personal injury.
16F Parkview Office Tower, Jeongja-dong, Bundang-gu,
Seongnam, Gyeonggi, 463-863 Korea
Tel: +82-31-783-4502
Fax: +82-31-783-4503
Sales inquires: [email protected]
Technical inquires: [email protected]

Copyright © 2005 by Suprema Inc. http://www.supremainc.com Copyright © 2005 by Suprema Inc. http://www.supremainc.com

You might also like