0% found this document useful (0 votes)
117 views1 page

HAWKE GLAND-type Only

This document provides information on selecting cable glands for flameproof and increased safety applications. It includes: - A selection table with details on cable gland sizes, thread types, dimensions and cable acceptance ranges. - Information on alternative reversible armour clamping rings. - Features of the cable glands like providing armour and seal clamping. - Technical data on approvals, standards, materials, finishes and ingress protection ratings.

Uploaded by

Jaaffer Ali
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
117 views1 page

HAWKE GLAND-type Only

This document provides information on selecting cable glands for flameproof and increased safety applications. It includes: - A selection table with details on cable gland sizes, thread types, dimensions and cable acceptance ranges. - Information on alternative reversible armour clamping rings. - Features of the cable glands like providing armour and seal clamping. - Technical data on approvals, standards, materials, finishes and ingress protection ratings.

Uploaded by

Jaaffer Ali
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 1

15.

0mm

Metric
'G' Approx (Compressed Length)

Armour/Braid
Cable Gland Type
501/453/RAC
Entry 'C'

ATEX
Entry Thread

Ø 'A'

Ø 'B'
Flameproof and Increased Safety

Application
CABLE GLAND SELECTION TABLE
Cable Acceptance Details Outdoor or Indoor use.
Entry Thread Hexagon For use with single wire
Inner Sheath 'A' Outer 'C'
Size Size Dimensions armoured 'W', wire braided 'X'
Standard Alternative Sheath Armour/Braid 'G' and steel tape armoured 'Z',
Ref. NPT* Seal Seal (S) 'B'

501/453/RAC Cable Gland


Metric Std./ Across Across elastomer and plastic insulated
Option Min. Max. Min. Max. Min. Max. Orientation
1
Orientation
2
Flats Corners cables.
Os M202 ½" - - 5.5 12.0 0/0.7 65.1 24.0 27.7 See technical section of
3.0 8.0 0.9/1.25
2 catalogue for installation rules
O M20 ½" 7.5 11.9 - - 9.5 16.0 0.9/1.25 0/0.7 65.1 24.0 27.7 and regulations.
A M20 ¾"/½" 11.0 14.3 8.5 13.4 12.5 20.5 0.9/1.25 0/0.7 66.1 30.0 34.6
B M25 1"/¾" 13.0 20.2 9.5 15.4 16.9 26.0 1.25/1.6 0/0.7 71.4 36.0 41.6
C M32 1¼"/1" 19.0 26.5 15.5 21.2 22.0 33.0 1.6/2.0 0/0.7 75.2 46.0 53.1 Features
C2 M40 1½"/1¼" 25.0 32.5 22.0 28.0 28.0 41.0 1.6/2.0 0/0.7 77.1 55.0 63.5 Provides armour clamping
D M50 2"/1½" 31.5 44.4/42.31 27.5 34.8 36.0 52.6 1.8/2.5 0/1.0 90.3 65.0 75.1 using one clamping
E M63 2½"/2" 42.5 56.3/54.31 39.0 46.5 46.0 65.3 1.8/2.5 0/1.0 96.7 80.0 92.4 arrangement for all armour/
F M75 3"/2½" 54.5 68.2/65.31 48.5 58.3 57.0 78.0 1.8/2.5 0/1.0 96 95.0 109.6 braid types.
Provides a seal on the cables
Larger cable glands available in 501/453 design. See page 23. inner sheath.
G M80 3½" 67.0 73.0 - - 75.0 89.5 # # 95.6 106.4 123.0 Deluge protection option
H M90 3½" 67.0 77.6 - - 75.0 89.5 # # 95.6 115.0 132.8 available.
J M100 4" 75.0 91.6 - - 88.0 104.5 # # 95.6 127.0 146.7 Provides a cable retention and
1 Smallervalue is applicable when selecting reduced NPT entry option. low smoke and fume, zero
2 SizesOs and O are available with an M16 thread size. For O size with M16 thread, halogen seal onto the cables
the maximum cable inner sheath diameter is 10.9mm. outer sheath.

General Information Alternative Reversible Armour


Clamping Rings (RAC) Technical Data
All Metric entry threads are 1.5mm pitch
medium fit. Flameproof EExd and Increased
SELECTION TABLE
All dimensions in millimetres Steel Wire Armour/Braid/Tape
Safety EExe. II 2 GD
Size
(except* where dimensions are in inches). Ref. Orientation 1 Orientation 2 Baseefa Certificate No.
# Dedicated armour clamping rings are O/Os 0.8 - 1.0 0.4 - 0.8 BAS 01 ATEX 2072X. For Os - F.
fitted. Please specify armour type and A 0.8 - 1.0 0.4 - 0.8 Baseefa Certificate No.
B 0.9 - 1.25 0.5 - 0.9 BAS 01 ATEX 2296X. For G - J.
size. C 1.2 - 1.6 0.6 - 1.2
Assembly instruction data sheet No. A.I. 302. C2 1.2 - 1.6 0.6 - 1.2 Suitable for use in Zone 1,
For sizes Os to F. D 1.45 - 1.8 1.0 - 1.45 Zone 2, Zone 21 and Zone 22.
E 1.45 - 1.8 1.0 - 1.45 Suitable for use in Gas Groups
Assembly instruction data sheet No. A.I. 329. F 1.45 - 1.8 1.0 - 1.45
For sizes G to J. IIA, IIB and IIC.
Construction and test standards
Accessories including locknuts, sealing washers, serrated washers, earth tags, shrouds, EN 50014, EN 50018, EN 50019
adaptors and reducers available. See pages 44 - 48. and EN 50281-1-1.
IEC 60079-0, IEC 60079-1 and
Materials & Finishes IEC 60079-7.
The 501/453/RAC cable gland is manufactured as standard in brass, stainless steel IP66, IP67 and IP68 (30 metres for 7 days)
and aluminium. NPT entries, nickel plated as standard. Full nickel plating available. ingress protection to IEC 60529,
EN 60529 and NEMA 4X.
DTS01 deluge protection
Cable Gland Ordering Examples certified by ITS.
Cable Gland Type/Size/Thread Cable Gland with Alternative Operating temperature range
Clamping Ring (AR) -60°C to +80°C as standard.
e.g. 501/453/RAC/C/M32 Alternative Certification Options Available.
501/453/RAC/C/1¼" NPT e.g. 501/453/RAC/C/M32/AR
501/453/RAC/C/1¼" NPT/AR Exd IIC/Exe II.

Cable Gland with Alternative Seal (S) BR-Exd IIC/Exe II.

GOST R-Exd IICU/Exe IIU.


e.g. 501/453/RAC/C/M32/S
501/453/RAC/C/1¼" NPT/S AUS-Exd IIC/Exe II.

Smarter products