Assessment - Extreme Flash & NVME Overview and Best Practices

1In the
Mark for
. Extreme
Review 
Flash
(5) Points
servers
SAS
controllers
are still
used to
report
disk
errors.

True
False (*)

Incorrect. Refer to the course


Exadata Elastic Configuration Rules
& Best Practices for more
information.

2. The High Capacity servers alo have NVMe flash drives


Mark for Review 
installed directly into the PCIe slots internal to the srever,
(5) Points

True (*)
False

Correct

3. The Extreme Flash servers always have four of this type of


Mark for Review 
PCIe cards installed internally?
(5) Points

Fast Write Cache Cards


NVME Cache cards
SAS Disk Control Cards
PCIe Switch Cards (*)

Incorrect. Refer to the course


Exadata Elastic Configuration Rules
& Best Practices for more
information.

4. The PCIe switch cards have 4 ports but only use three, so
Mark for Review 
which of these is correct.
(5) Points

The PCIe switch card uses ports 0,2,and3.


The PCIe switch card uses ports 2,3,and4.
The PCIe switch card uses ports 1,2,and3.
.
The PCIe switch card uses ports 0,1,and2. (*)

Incorrect. Refer to the course


Exadata Elastic Configuration Rules
& Best Practices for more
information.

5. The logical disk numbers will always match the physical slot
Mark for Review 
number?
(5) Points

Yes
No (*)

Incorrect. Refer to the course


Exadata Elastic Configuration Rules
& Best Practices for more
information.

6It is OK
Mark for
. to
Review 
remove
(5) Points
a drive
in the
Extrem
e Flash
servers
when:

there is a blue LED indicatopr lit on the drive. (*)


there is a flashing service LED on the drive.
there is a red LED indicator lit on the drive.
there are no LED indicators lit on the drive.

Incorrect. Refer to the course Exadata


Elastic Configuration Rules & Best
Practices for more information.

7. At the release of Extreme Flash there are only two supported


Mark for
configurations, which are base and full. Select the two
Review 
answers that indicate the number of drives supported for these
(5) Points
configurations.

(Choose all correct answers)


24
6
8 (*)
12 (*)

Correct

8. Each PCIe switch card is connected to, up to __ drives in each


Mark for
disk group.
Review 
(5) Points

3 (*)
5
4
6

Correct

9. The logical drives seen by the operating system on an


Mark for
Extreme Flash server will be found in :
Review 
(5) Points

/dev/usb
/dev/st
/dev/nvme (*)
/dev/sd

Correct

10. Extreme Flash has replaced High Performance servers with


Mark for
the X5 release of Exadata.
Review 
(5) Points

True (*)
False
Correct

2Which of
Mark for
. these
Review 
command
(5) Points
s would
be used to
show the
logical
disk to
physical
disk
mapping?

cellcli -e list physicaldisk detail (*)


dcli -e list disk detail
dcli -e list physicaldisk detail
onecommand -disk_mapping
cellcli -e list disk detail

Incorrect. Refer to the course Exadata


Elastic Configuration Rules & Best
Practices for more information.

3. The Extreme Flash Servers provide more than double the flash
Mark for
storage capacity of the previous High Performance Storage
Review 
server.
(5) Points

True
False (*)

Incorrect. Refer to the course Exadata


Elastic Configuration Rules & Best
Practices for more information.

The
Mark for
Extreme
Review 
Flash
(5) Points
Servers
provide
more than
double the
flash
storage
capacity of
the previous
High
Performanc
e Storage
server.

True
False (*)

Incorrect. Refer to the course Exadata Elastic


Configuration Rules & Best Practices for more
information.

Hello Pankaj,

The customer respond us today, saying it was wrong command was written by the customer. It seems
they put the command on the different cluster nodes.

Please find I right command output of the list patches

You might also like