Coolmay 3G PLC, All-In-One USB Programming Port Drive Installation Steps in WIN7&WIN10

Download as docx, pdf, or txt
Download as docx, pdf, or txt
You are on page 1of 12
At a glance
Powered by AI
The document outlines the steps to install a USB programming port driver for Coolmay PLC devices in Windows 7 and Windows 10. It describes disabling digital signatures in Windows 10, manually installing the USB driver, and checking the device manager after installation.

You need to restart the computer in advanced startup mode, select startup settings, and press F7 or the 7 key on the keyboard to disable driver enforcement signature.

You need to copy an .inf file to the USB driver folder, connect the USB cable, update the driver in device manager by browsing to the USB driver folder, and select the .inf file.

Coolmay 3G

PLC/PLC All-in-one
USB programming port
drive installation steps in
WIN7&WIN10

Shenzhen Coolmay Technology Co.,Ltd

V12.15

1 www.coolmay.com
Note: Please colse the digital signature first when you using os WIN10, then
manually install Mini type B USB programming port drive.

The steps of closing digital signature in WIN10 are as below:


---After setting third step, you will enter the restart setting interface. It is
recommended to take photos from step from 4-8 or remember the setting
method before you operation next.

1、Click the Start menu button --- click on Settings

2 www.coolmay.com
2 、 Enter the settings window , click update and security ( windows
update、recovery、backup);

3、Click recovery,then click "Start Now" in the advanced startup, after


rebooting, you will enter the following window.

3 www.coolmay.com
4、After rebooting, pop up the first window as below and click "Troubleshoot"

4 www.coolmay.com
5、Then enter the second window, click advanced options

6、Then click ‘Startup Settings’

5 www.coolmay.com
7、After entering the startup settings window, you need to click "Restart" to
activate the software;

8、After restarting the startup settings interface, press the number key 7 or F7
on the keyboard to disable the driver enforcement signature.

6 www.coolmay.com
After drive enforcement signature prohibited and computer restarts, then
manually boot the Mini B type USB programming port driver

The Mini type B USB programming port WIN7 system and WIN10 system
(execute after digital signature have been closed) drive need to be manually
installed, the steps are as follows: unzip《3G series PLC&PLC all-in-one USB
programming port drive_WIN7 os 》 , cover file of ECUsbd.inf as below to
C:\MELSEC\Easysocket\USBDrivers ( The path can be found according to
the installation path of the PLC programming software).

1. After the operation is completed, connect the USB programming cable

to the computer and open the device manager. Unknown devices will
appear in other devices. Right-click to update the driver software. The
operation steps are as follows:

7 www.coolmay.com
8 www.coolmay.com
9 www.coolmay.com
In the above figure, the path of “browsing the driver files on the computer”
should be corresponding to the USBDrivers in the PLC programming software
installation path (the same as the coverage path of the first step ECUsbd.inf
file), as shown below, click

10 www.coolmay.com
11 www.coolmay.com
When the USB driver is successfully installed, one of the device
manager's Universal Serial Bus controllers will be added, as shown below.

After the installation finish, you can use the usb cable to download the
PLC

program.

12 www.coolmay.com

You might also like