Ethylene Oxide Gas (Eto) Sterilizers: DE LAMA Holds The Quality System Certificates ISO 9001 and EN 46001
Ethylene Oxide Gas (Eto) Sterilizers: DE LAMA Holds The Quality System Certificates ISO 9001 and EN 46001
Ethylene Oxide Gas (Eto) Sterilizers: DE LAMA Holds The Quality System Certificates ISO 9001 and EN 46001
STERILIZERS
- double wall body Sterilizers are available with single or double door, hinged or
- sterilization chamber in AISI 316 or AISI 316L stainless steel automatic sliding type.
PROCESS CONTROL
All DE LAMA control systems are provided with marking • up to 35 standard storable programmes
and are in compliance with European Directive EMC 89/336 • self-diagnostic
relevant to electromagnetic compatibility. • data holding in case of black-out
To satisfy Customers’ several production needs, DE LAMA • possibility of connection to an external PC for real-time
has realized different and flexible control system configurations. logger and data storage functions
All controllers give the possibility of data processing and to
issue detailed process documentation. On Customer’s request, DE LAMA can supply:
DE LAMA MASTER 6 - customized systems able to interface with supervisors
Distributed architecture modular control, processing and (SCADA) and external control facilities
recording system with industrial PC connected to a PLC - independent recording system for process data (according to
European Standard EN 1422)
• VGA colour LCD monitor (TFT 800x600)
• multifunction keyboard membrane type
• track-ball
• colour graphic printer with printout size A4
STERILIZATION PROGRAMMES
• interface Ethernet IEEE 802.3 and Profibus
• self-diagnostic and self-test High flexibility of control systems mounted on autoclaves
• graphic programming DE LAMA DLOG and DE LAMA DLOG/V allows to perform
• configurable dynamic synoptic panel cycles, automatic control cycles (vacuum leak test
• human / machine interface (HMI) with graphic management pressure leak test) and cycles free programmable by
• Windows-NT® / 2000 Professional® operating system It is possible to choose operating parameters (time,
• integrated management of all process parameters and humidity, gas concentration, etc.) according to type
sequences load, packaging and product placing inside the chamber.
Standard operating values are the following:
Sterilization time: usual gas exposure time is 3÷4 hours.
Sterilization time depends on both type of packaging and
other process parameters.
Product temperature: 40÷60°C
Set temperature value is non-stop holded by forced circu-
lation of water inside the jacket and, optionally, inside the
3 bar
(300kPa)
60°C (333 K)
Sterilizer DE LAMA DLOG 931 type, 2 bar 50°C (328 K)
(200kPa)
40°C (313 K)
capacity 37734 lts., with hinged motorized door
1 bar ATMOSPHERIC
(100kPa) PRESSURE
0,2 bar
(20kPa)
GAS INLET
HUMIDIFICATION
VACUUM LEAK TEST
AIR REMOVAL
PRESSURE
Typical sterilization cycle
Functional diagram
Gas heater
Air inlet
Magnetic
coupling fan
CPU
Temperature probes
Pressure transducer
EtO gas mixture Humidity probe
bottle
TE01
TE02
TE03
TP
RH %
CPU Jacket
Heater of water
recirculating inside the jacket Chamber
Separating
Steam generator tank
Drain to be
conveyed to
neutralization
system
AUXILIARY EQUIPMENT
OPTIONALS
Doors heating through hot water flushing
Doors motorization system with electronic control
Automatic translation system for doors opening/closing
Internal ventilation system, with magnetic coupling fan groups,
to optimize homogeneity conditions throughout the
chamber (according to European Standard EN 1422)
Gas injection pipes washing system by nitrogen flux
Exhaust hoods for suction of eventual residual gas on doors
opening Sterilizer DE LAMA DLOG 541 type,
Electronic gas weighing system capacity 10875 lts., with hinged door
ADPE explosion-proof execution for sterilizers under vacuum
( DE LAMA DLOG/V)
TECHNICAL DOCUMENTATION
QUALITY CONTROL
AND ADDITIONAL ACTIVITIES
AND VALIDATION
To complete the supply, plants are always provided with
Equipment and relevant supervision systems are designed and following basic documentation:
manufactured to be easily validable in compliance with European - installation and operation manuals
Standard EN 550 and with quality standards for pharmaceutical
- P&I and technological diagrams
processes required by FDA.
- dimensional drawings and lay-out
Careful tests, specific controls and high technical professionality
in pre-validation activities assure that plants are fully in com- - bill of materials and components
pliance with highest required standards. - materials and calibration certificates
On request, DE LAMA supplies:
FAT and SAT protocols/documentation for pre-validation
Validation documentation customizable by the end-users
Full documentation for EN or FDA activity of validation
Theoretical/practical trainings reserved to Customers’
production and maintenance staff.
ASSOCIATED EQUIPMENT
AND ACCESSORIES
TO COMPLETE THE PLANT
Stainless steel trolleys for internal loading and external
moving, trays and boxes
Idle/motorized rollers internal conveyor for europallets
Full customized systems for loads handling
Models indicated in above table are only some of standard sizing for DE LAMA DLOG and DLOG/V.
Apart from the standard configurations indicated in the table, sterilizers can be proposed even with other dimensions, on request, according to
DLOG IN. 06 - 02
Customer's production needs.
Working parameters are for indication only and and can be modified in relation to Customer’s working requirements.