ALARM Manual8088
ALARM Manual8088
Copyright Notice
This manual is furnished under license and may be used or copied only in accordance with the terms of such license. Except as
permitted by such license, no part of this publication may be reproduced, stored in a retrieval system, or transmitted, in any form or
any means, electronic, mechanical. Recording, or otherwise, including translation to another language or format, without the prior
written permission of secBo. The content of this manual is furnished for informational use only, is subject to change without notice,
and should not be construed as a commitment by secBo. secBo assumes no responsibility or liability for any errors or inaccuracies
that may appear in this book. All other product names, trademarks and registered trademarks in this document are the properties of
their respective holders.
Warranty
secBo warrants this product will be free from defects in materials and workmanship for period of time specified on the product
packaging. This limited warranty shall commence from the date of purchase. secBo products warranty is not transferable and is
limited to the original purchaser. If the product is found to be defective then, as your sole remedy and as the manufacturer's only
obligation, secBo will repair or replace the product. The warranty shall not apply to products that have been subjected to abuse,
misuse, abnormal electrical or environmental conditions, normal wear and tear or any condition other than what can be considered
normal use.
Limitation of Liability
The liability of secBo arising from this warranty and sale shall be limited to a refund of the item price. In no event shall secBo be
liable for costs of procurement of substitute products or services, or for any lost profits, or for any consequential, incidental, direct or
indirect damages, however caused and on any theory of liability, arising from this warranty and sale. These limitations shall apply
not withstanding any failure of essential purpose of any limited remedy.
2
Table of Contents
Introduction..............................................................................................................................................................................................................4
Main Features..........................................................................................................................................................................................................4
Main Alarm Host (SB-LL8088)................................................................................................................................................................................5
Alarm Host Specifications.....................................................................................................................................................................................5
Main Alarm Host (SB-GL8088)...............................................................................................................................................................................6
Alarm Host Specifications.....................................................................................................................................................................................6
Zone Definition........................................................................................................................................................................................................7
Zone Types and Definitions...................................................................................................................................................................................7
Modes of Arming...................................................................................................................................................................................................7
Startup the Alarm Host (LAND LINE SB-LL8088).................................................................................................................................................7
Preparation............................................................................................................................................................................................................7
Startup the Alarm Host (GSM SB-GL8088)...........................................................................................................................................................8
Preparation............................................................................................................................................................................................................8
GSM Signal Indicator............................................................................................................................................................................................8
GSM Signal Level.................................................................................................................................................................................................8
System Setup...........................................................................................................................................................................................................9
Wired Sensor Connection (Optional)..................................................................................................................................................................16
Change Programming Password.........................................................................................................................................................................17
Operating the Alarm Host.....................................................................................................................................................................................18
Descriptions of Wireless Accessories................................................................................................................................................................20
Wireless Remote (SB-88X).................................................................................................................................................................................20
Wireless Panic Button (SB-89)...........................................................................................................................................................................21
Wireless Door Sensor (SB-87B).........................................................................................................................................................................22
Wireless Wide-Angle PIR Sensor (SB-80)..........................................................................................................................................................23
Wireless Indoor Siren (SB-103W).......................................................................................................................................................................25
Wireless Gas Detector (SB-85, optional)............................................................................................................................................................26
Wireless Smoke Detector (SB-93, optional).......................................................................................................................................................27
Wireless Keypad (SB-CJP, optional)...................................................................................................................................................................28
Wireless Outdoor Siren (SB-103HK, optional)....................................................................................................................................................31
Wireless Outdoor Photoelectric Beam Detector (SB-ABT, optional)..................................................................................................................32
Quick guide on how to activate and deactivate wireless accessories............................................................................................................33
Common Problems and Solutions......................................................................................................................................................................34
Daily Maintenance and Care.................................................................................................................................................................................35
Accessories...........................................................................................................................................................................................................35
3
Introduction
secBo 8088 series is a state-of-the-art wireless alarm system for home and office security. It is user friendly and you
can install the system and monitor your home / office all by yourself. When alarm is triggered, the system can call to
your preset phone numbers (for SB-LL8088 and SB-GL8088) or send SMS to alert (for SB-GL8088) and you can
control the system operations in a remote distance.
Main Features
• Integrated wireless alarm system.
• Concise and elegant design with simple operating interface, CID communication protocol.
• LCD screen with calendar, available in English (optional: also available Chinese, German, Russian, French, Spanish
and Japanese etc.)
• One-key arm operation, coding wireless sensors.
• With 30 wireless alarm zones, up to 4 sensors within a zone, GSM SMS alert and Telephone alarm.
• Can preset 5 groups telephone, with functions of recording, voice indicating and monitoring.
• Can distinguish alarming information intelligently, prevent mis-alarms & missing-alarms.
• Alarming priority, history records backup once power failure , AC/DC power both available.
• 5 methods Arm/Disarm: Remote Controller, Host Keypad , Remote Controlling Keypad (optional) , Telephone/Mobile
phone, and GSM SMS (SB-GL8088 only).
4
Main Alarm Host (SB-LL8088)
6
Zone Definition
Zone Types and Definitions
• Perimeter zone (Outer zone defense): Detecting the space like doors, windows, etc., generally use wireless
door magnet sensors and wireless curtain PIR sensors.
• Motion zone (Inner Zone defense): Detecting the space like living room, aisles and bedrooms, room doors etc.,
generally use wireless wide-angle PIR sensors and door sensors.
• Emergency zone: Detecting the space like Emergency area (such as emergency distress, medical rescue, gas
leakage, smoke and fire alarm, etc., this zone keep 24-hour monitoring status automatically. Generally use panic
button, wireless gas sensors and wireless smoke sensors.
Modes of Arming
• “Away Arm” mode: Once any detectors in perimeter zones or motion zones get triggered, the host will set off
the alarm immediately and dial your preset numbers automatically.
• “In Home Arm” mode: Once any detectors in perimeter zones get triggered, the host will alarm immediately and
meantime dial dial your preset numbers automatically. It will not alarm after any detectors in the motion zone are
triggered.
8
System Setup
The detailed menus in the SET button are shown below:
【Set time】:
This is for setting the host time.【ENT + press button a few times to delete the old record, then press
HHMMSS + ENT】→ HHMMSS: 6 digits, meaning hour (HH), minute (MM), second (SS), each takes 2 digits
space. For example 14:21:20, you may press 142120, now the host time will be 14:21:20. For invalid time, it
cannot be saved by pressing ENT.
【Set date】:
This is for setting the host date.【 ENT + press button to delete the old record , then press
YYMMDDW + ENT】→ YYMMDDW: 7 digits, meaning year (YY), month (MM), day (DD), week (W). For
example 2010/12/17 Thursday, you may press 1012174, now the host date will be 2010/12/17 Thursday. “0”
means Sunday.
【Auto Dialer#’s】(SB-LL8088):
This is for presetting Call Center and Reporting telephone numbers.
• In total 5 telephone/mobile numbers.
• Press ▲ or ▼ button to select the report method:
“Call Center” for connection to a call center, “Personal Nbr” to a personal number.
10
• Press button to delete any old record, input the phone number you wish the system will dial to.
• Press ENT to confirm each phone (telephone/mobile) number. Repeat process for 2nd phone number, 3rd phone
number etc.
【Auto Dialer#’s】(SB-GL8088):
This is for presetting Reporting telephone numbers or Reporting SMS (SB-GL8088)
• In total 5 telephone/mobile numbers.
• Press ▲ or ▼ button to select the report method:
“Personal Nbr” to a personal number,
• Press button to delete any old record, input the phone number, press ENT
“SMS Phone No.” for voice alarming, “SMS Reporting” for SMS alarming. If you choose “SMS Reporting”, it will
just send to mobile numbers not include home phone numbers.
• Press ENT to confirm each phone (telephone/mobile) number. Repeat process for 2nd phone number, 3rd phone
number etc.
【Entry delay】:
This is for setting delay time of alarm to allow you to disarm the system in a limit amount of time.
【ENT + press button to delete old record + XX + ENT】→ XX: 2 digits, you can set 00~59 seconds, the
default value is “00”. This setting can only work when the relevant zone is enabled in 【Zone
Attribute】: with entry delay set (See page 13 for details).
11
【Exit delay】:
This is for setting delay time of arming.
【ENT + press button to delete old record + XX + ENT】 → XX: 2 digits, you can set 00~59 seconds, the
default value is “15”.
【Siren On/Off】:
The system has 3 zones (Perimeter Zone, Motion Zone and Emergency Zone) for your options to enable or disable
the siren when sensors are triggered. Operations are as below:
【ENT + Siren On/Off, press ▲ or ▼ button to choose ON or OFF + ENT】.
If ON is chosen, the siren will alarm when sensors are triggered. You need to setup the alarming duration time
(minutes) in the next sub-menus. Please do as following:
【press button to delete old record + XX + ENT】→ XX: 2 digits, you can set 00~60 minutes, the defaults are
“01” (1 minute) for emergency zone, “01” (1 minute) perimeter zone and “02” (2 minutes) for motion zone.
If OFF is chosen, the siren will NOT alarm when sensors are triggered. You then need to setup the alarming
duration time (minutes) to “00” to complete the setup.
【Arm/Disarm Beep】:
【ENT + ▲ or ▼ button + ENT】→ ▲ or ▼ button choose “YES” or “NO” for having a “bi” sound when arm or
disarm the alarm host. The defaulted is “YES”.
【User code】:
Only use for linking network.【ENT + press button to delete old record + XXXX + ENT】→ XXXX: 4 digits,
you can set 0000~9999. Default user code 0001.
12
【Upload Status?】:
This is for uploading Arm / Disarm / Alarm / power cut information to the 1st personal number you installed in auto
dialer number section.【ENT + ▲ or ▼ button + ENT】→ ▲ or ▼ button choose “YES” or “NO” for upload or not
upload the status. Default value is “NO”.
【Zone Attribute】:
This is for setting【Zone number】,【Zone type】,【Bypass Zone】, and【Attribute Set】.
【Zone number】:
The system has 39 zones for your settings. 29 wireless zones (each zone supports up to 4 sensors), 8 wired
zones (optional) and 2 dedicated zones for remotes (supports up to 4 remotes or wireless keypads per zone).
Each zone needs to setup “Zone Type”, “Bypass Zone”, and “Entry Delay”.
【Zone type】:
You can see “2”, “1”, “0”. (“2” = motion zone, “1” = perimeter zone, “0” = emergency zone)
Press ▲ or ▼ button to allocate the type of zone for a particular zone number, then press ENT to confirm your
settings.
【Bypass Zone】:
This setting is to enable or disable setting zones. “YES” means bypassing (disable) the sensor, “NO” means
keep this zone’s sensors working. Press ▲ or ▼ button to choose “YES” or “NO”, then press ENT to confirm
your settings.
13
【Entry delay Set】:
This is for enabling the zone entry delay settings. “YES” means make this setting valid, “NO” means there is no
entry delay for this zone. Press ▲ or ▼ button to choose “YES” or “NO”, press ENT to confirm your settings.
Note:Press ESC to exit from the programming status after finish settings. The system will return back to
idle after 30 seconds.
Below are the “Zones Attribute” lists for wireless sensors programming for your reference:
Zone
Zone Type Bypass Zone Entry Delay Set Compatible Accessories Remarks
Number
Wireless Key chain remote &
00 ~ 01 —— No Yes
Wireless Keypad
Emergency Wireless Smoke Alarm,
02 ~ 10 No Yes
zone Gas Alarm & Panic button. Support up to 4 sensors
Perimeter Wireless Door Magnet & per zone
11 ~ 20 No Yes
zone Wireless Curtain PIR
Wireless Wide-Angle PIR
21 ~ 30 Motion zone No Yes
Motion Sensor
Only on land line Model
31 ~ 38 Wired zone No Yes Wired Sensor (Optional)
SB-LL8088(C)
【Program Sensor】:
This setting is for adding or deleting sensors in the above mentioned zones (including zone 00, 01). The detailed
operations are as below:
In “Program Sensor” menu, press ENT to choose “Zone Number” from different “Zone Types” (00~01, 02~10,
11~20, 21~30, 31~38). E.g. if you want to learn a smoke alarm (belongs to Emergency Zone) to the alarm host, you
have to choose the “Zone Number” from 02~10 (Emergency Zone). If there are old records, press button to
delete, input new number using the keypad, press ENT to get into the “Group Number” setting mode.
14
This “Group Number” is for sensors’ numbers, each zone can connect 4 sensors. The “Group Number” is from 00 to
03. “00” means Sensor 1, “01” means Sensor 2, “02” means Sensor 3, “03” means Sensor 4. Press ENT to get into
“Activate Sensor/ Delete Sensor” mode, press ▲ or ▼ button to choose Activate Sensor / Delete Sensor settings.
If “Activate Sensor” is chosen
To add a sensor to the host, choose “Activate Sensor”. The word “Learning” will show on the LCD Screen,
trigger the sensor you want to learn by the host, the word “success” will show on the LCD Screen once it
receives the sensor signal.
Note: If a word “update?” shows on the screen, which means this sensor has already been added
before, you can choose “Yes” or “No” to decide if you want to override the previous setting for this
sensor.
Wireless Key chain Wireless Door / Wireless Wide-Angle Wireless Curtain Wireless Gas Wireless Smoke
Sensor Types Remote Window Sensor PIR Motion Sensor PIR Sensor (N/A) Alarm (N/A) Alarm
The Default
00 11 21 12 02 02
Zone number
【Messages】(SB-LL8088 only):
Default “No record” - reserved for future revisions.
15
【Alarm History】:
This is for checking the alarm history records. The system is able to memorize up to 100 records with Alarm Status
and time & date.
Operations: Go to the “Alarm History” menu, press ENT to check the first “00” alarm history record, press ▼ button
to view next history records. Press ESC to exit.
【Status History】:
This is for checking the ARMED or DISARMED time record of the system. The system is able to memorize up to 100
records with time & date.
Operations: Go to the Status History menu, press ENT to check the first “00” status history, press ▼ button to view
next status history records. Press ESC to exit.
NC – Normally closed type sensor connection (with self power and without self power)
16
NO – Normally open type sensor connection (with self power and without self power)
17
Operating the Alarm Host
Record: Slide the switch on the host panel side to “RECORD ON”,press and hold the button and speak close to
the speaker of the host, and then release, the voice recorded.
Play: Slide the switch on the host panel side to“DC, press and hold the button and you will hear the previous
record.
Arm: By wireless remote: press the arm button and the host will beep once and enter the “armed away” mode.
By Host panel (Keypad):【0 + password + ENT + ▲ or ▼ + ENT】 → ▲ or ▼ button to choose “armed
home” or “armed away”
Disarm: By wireless remote: press the disarm button and the host will beep twice to exit from “armed away” mode.
By Host panel (Keypad):【ESC + password + ENT 】 → the host will beep twice to successfully complete
the operation
Emergency: By wireless remote: press the Emergency key and the host will alarm immediately.
By Host panel (Keypad): press the button,and the host will alarm immediately.
Telephone alarm: After receiving the call, you will hear the recorded voice message immediately, it can be played for
30 seconds repeatedly, then follow the below instruction:
- Input “8” to enter into the listening status for 20 seconds, you can hear the alarm background
sounds from phone.
- Input ”#” to play the recorded voice message for one time.
- Input “*”, the host will end the call and stop dialing any auto dialer #.
- Directly hang off the telephone, the host will end the call and automatically dial the next auto dialer #.
SMS reporting (SB-GL8088): Mobile will get SMS like “System Alarming XX, YYYY”, “XX” means zone number,
“YYYY” means the detailed sensor.
18
Arm remotely by phone: 30 seconds after successfully dial the phone number of the host, enter the password of the
host after the beep, then enter 1 after beep, the host will automatically hang up after beep to complete the
operation.
Notes: You can set “Armed Away” remotely by phone, but note that you can’t set “Armed Home” by this way.
Disarm remotely by phone: 30 seconds after successfully dial the phone number of the host, enter the password of
the host after the beep, then enter 0 after beep, the host will automatically hang up after beep to complete the
operation.
Arm by SMS (SB-GL8088): You can send the SMS message “XXXXXXBF” from your mobile phone to the host
panel. XXXXXX is your password. The host panel would arm automatically when getting this SMS, and also will
message back to mobile “Arm successfully”.
Note: Arm by SMS only has “Armed away” option!
Disarm by SMS (SB-GL8088): You can send the SMS message “XXXXXXCF” to host panel. XXXXXX is your
password. The host panel would disarm automatically when getting this SMS, and also will message back to mobile
“Disarm successfully”.
Look up alarm history: Press ▲ or ▼ button to find the “Alarm history”, and then press ENT to look up the previous
alarm history, at most 100 pieces of history are available can be saved.
Look up status history: Press ▲ or ▼ button to find the “Status history”, and then press ENT to look up the previous
alarm history, at most 100 pieces of history are available can be saved.
Alarming dialing mode: After the host goes off, it starts to repeatedly dial the auto dialer#’s for three times one by
one from the first one. The answered number will not be dialed again.
Power disconnection: If power got disconnected, the host panel will sound “di” every 8 seconds.
19
Descriptions of Wireless Accessories
Wireless Remote (SB-88X)
Features
Away
• To control the alarm host to arm and disarm or set off alarm.
• With the emergency key for urgent help. Disarm
Home
Specifications
Emergency
• Operating power: 27A 12V alkaline battery
• Emitting distance: ≥100m (in open area)
• Service life: ≤1 year
How to program
Please refer to the descriptions of【Program Sensor】on page 14 or table on page 33.
Notes:
• You can add one by one in turns, a maximum of 8 remotes can be added.
• If there is already a remote set to the zone memory location, a new remote set to the same memory location will override it.
20
Wireless Panic Button (SB-89)
Features
• To allow immediate alarm set off by pressing it once.
• Place beside beds, under tables, or let the elderly carry along with them.
Specifications
• Operating power: 27A 12V alkaline battery
• Emitting distance: ≥100m (in open area)
• Service life: ≤1 year
How to program
Please refer to the descriptions of【Program Sensor】on page 14 or table on page 33.
Notes:
• You can add one by one in turns, a maximum of 8 panic remotes can be added.
• If there is already a panic remote set to the zone memory location, a new panic remote set to the same memory location will
override it.
21
Wireless Door Sensor (SB-87B)
Features
• Generally set in Perimeter zone or Motion zone.
• If any door or window is opened, it will transmit the alarm signals to the alarm host.
Specifications
• Operating power: 23A 12V alkaline battery
• Frequency: 433MHZ
• Emitting distance: ≥100m (in open area)
• Service life: ≤1 year
• Alarm Distance: <4cm
How to program
Please refer to the descriptions of【Program Sensor】on page 14 or table on page 33.
Notes:
• You can add one by one in turns, a maximum of 4 sensors can be added in each zone.
• If there is already a door sensor set to the zone memory location, a new sensor set to the same memory location will override it.
22
Wireless Wide-Angle PIR Sensor (SB-80)
Features
• Mainly monitor and control indoor space, generally set as Motion zone.
• When human body enters into detecting area, the sensor will transmit alarm signals to the alarm host.
Specifications
• Operating power: 9V 6F22 battery
• Emitting distance: ≥100m (in open area)
• Service life: ≤1 year
• Detecting distance: 110° 10×10m
23
Installation and Usage
• Fix the bracket on suitable wall surface or in wall corner at a distance of 2~2.4m above the ground.
• Open the sensor shell to connect the batteries well and adjust jumper line (short circuit “5S”: The sensor will
detect once every 5 seconds; short circuit “5MIN”: The sensor will detect once every 5 minutes).
Suggestion: short circuit “5S” for testing and “5MIN” for normal use;
• Fix the sensor onto the bracket.
• Adjust the sensor to a proper angle and then slide the power switch on the side to “ON”, and it will enter into the
normal working state after 30 seconds.
• Upon the working light flashes frequently in green, please replace the batteries.
How to program
Please refer to the descriptions of【Program Sensor】on on page 14 or table on page 33.
Notes:
• You can only add 1 wireless wide-angle PIR sensor each time, totally 4 available to be added.
• If there is already a PIR sensor set to the zone memory location, a new PIR sensor set to the same memory location will override it.
24
Wireless Indoor Siren (SB-103W)
Features
• Work with alarm host, wireless receiving alarm signals,spot alarming with sound and flash.
• With power plug, usually for indoor use.
Specifications
• Operating Power: 100~240VAC
• Receiving Distance: ≥80 M (In open area)
How to program
Please refer to the descriptions of the table on page 33.
Notes:
• You can only add 1 wireless siren each time.
• When configure the wireless siren, you can only operation on the keypad of the alarm host.
• One siren can be studied to at most 10 wireless alarm hosts, multiple wireless sirens are available to be added for each alarm host.
25
Wireless Gas Detector (SB-85, optional)
Features
• Mainly monitor and control indoor gas leak, generally set as Emergency Zone.
• Usually installed in kitchen.
Specifications
• Operating power: 220~240VAC,50~60HZ
• Emitting distance: ≥100m (in open area)
• Inductive gas: Natural gas: 0.1%-0.5%
Liquefied petroleum gas (LPG): 0.1%-0.3% Working Light Air Hole
Test Button
Power Light
Installation and Usage
• Fix the gas alarm onto proper wall surface inside the kitchen.
• Connect the alarm to the power and it will be ready to detect after two minute.
How to program
Please refer to the descriptions of【Program Sensor】on page 14 or table on page 33.
Notes:
• You can only add 1 wireless gas detector each time, totally 4 available to be added.
• If there is already a gas detector set to the zone memory location, a new gas detector set to the same memory location will override
it.
26
Wireless Smoke Detector (SB-93, optional)
Features
• Mainly monitor and control indoor fire risks, generally set as Emergency Zone.
• Replace the batteries for every 1 or 2 year.
Specifications
• Operating power: 9V alkaline battery
• Emitting distance: ≥100m (in open area)
• Service life: ≤1 year
• Monitoring range: 20m
How to program
Please refer to the descriptions of【Program Sensor】on page 14 or table on page 33.
Notes:
• You can only add 1 wireless smoke detector each time, totally 4 available to be added.
• If there is already a smoke detector set to the zone memory location, a new smoke detector set to the same memory location will
override it.
27
Wireless Keypad (SB-CJP, optional)
Features
• LCD display, calendar function, upgraded and Micro-computer controlling, steady performance.
• Supported languages: English (other languages are available upon request).
• Work with wireless alarm host, with function of armed home / armed away, disarm, emergency.
• Including 3 codes: master code / user code / fixed code.
• Remembers programming settings when power is disconnected.
• Code recorded and resume function.
• Two power ports available, convenient and easy installation.
• User friendly
Specifications
• Power supply: 12VDC
• Maximum current: ≤50mA
• Working environment: temperature: -10~50°C humidity: ≤97%
• Product dimension: 125 × 125 × 25 (mm)
Operation and settings
Code type and function:
Code type: fixed code, master code, user code
Fixed code:999999, 6 digits, use to modify master code or user code, this code cannot be changed.
Master code:default 888888, 6 digits, use to control set time / date / wireless code
User code:default 888888, 6 digits, can control arming / disarming
How to set
• LCD screen will exit programming mode if without any operations within 30 seconds.
• It will be back to the last menu if press ESC menu.
28
• If three time putting wrong program code, the host will resume to the very original status.
• If input the codes 3 times by mistake, the host will be back to the standby mode automatically.
The detailed【Programs】is as below:
Press SET button getting into the programming mode, Enter Master Code (6 digits), the default master code is
“888888”, press ENT, you may see the below menus:
【Set Time】:
【ENT + press to clear old record + XXXXXX + ENT】→ XXXXXX: 6 digits, means “hour/minute/second”,
each takes two digits space.
【Set Date】:
【ENT + press to clear old record + XXXXXXX + ENT】→ XXXXXXX: 7 digits, means
“year/month/date/week”, first three setting take 2 digits space for each, and 1 digits space for week.
【Wireless Code】:
【ENT + XXXXXXXX + ENT】→ XXXXXXXX: 8 digits, named from “A0-A7”, can choose between ”2”, ”1”, “0”.
“2”means low level, “1” means high level, “0” means empty. This is only used for manual setup of the keypad code
that is used to match with the main alarm system unit, by default this is already chosen automatically.
Note: You can press ESC to exit programming mode when you finish the above operations.
29
Set user's code
【SET + 999999 + ENT + press ▲ or ▼ + ENT + enter old 6 digits user code + ENT + enter new 6 digits user
code + ENT + re-enter new 6 digits user code + ENT】→ press SET then enter 999999, press ENT then
press ▲ or ▼ to choose “User Code” then press ENT, 6 digits new user code, and then press ENT, then re-enter
the 6 digits new user code again, then press ENT (Factory default set is 888888).
Note: User code and master code can't be the same as the fixed code of 999999.
Operations
Arming
• Operated by code:【press 0 + enter 6 digits user code + ENT + press ▲ or ▼ + ENT】, press ▲ or ▼ to
choose “Armed Away” or “Armed Home”. You will hear the host sound “bi”, it means arming successfully.
Note: If you didn’t hear the host sound “bi”, it means failed in arming, you need to press “arm” again.
Disarming
• 【press ESC + enter 6 digits user code + ENT】, you will hear the host sound “bi bi”, it means disarming
successfully.
Note: If you didn’t hear the host sound “bi bi”, it means failed in disarming, and you need to press
“disarm” again.
Emergency
Press button, and the host will sound out alarming immediately.
How to program
Please refer to the descriptions of【Program Sensor】on page 14 or table on page 33.
Notes:
• You can only add 1 remote keypad each time, totally 8 available to be added.
• If there is already a wireless keypad set to the zone memory location, a new wireless keypad set to the same memory location will
override it.
30
Wireless Outdoor Siren (SB-103HK, optional)
Features
• Nice, exquisite and waterproof.
• Micro-computer controlling, steady performance and high-class quality.
• Study to at most 10 pieces of wireless alarm host.
• With inbuilt charging circuit and back up accumulators, automatic AC power and DC power transformation.
• Low standby power consumption, self-inspection of lower battery voltage, automatic charging.
• Wall hanging installation.
Specifications
• Operating power: 110~240VAC, 50Hz
• Current consumption: ≤20mA @ 12Vdc
• Backup Battery: 7.2V 500mA or 12Vdc 1.2A (optional)
• Siren current: 220mA @ 12Vdc
• Flash Current: 180mA @ 12Vdc
• Timer: 1 minute (Test), 3 minutes or 6 minutes
• Tamper Trigger: INT/EXT selectable
• Operating temperature: -10oC to 40oC
• Water splash resistant, Plastic PC with UV protection, conformal coated
circuit board
• Alarming volume: ≥110db
31
Wireless Outdoor Photoelectric Beam Detector (SB-ABT, optional)
Features
• Nice, exquisite and waterproof.
• Wide vision facing
• Micro-computer controlling, steady performance and high-class quality.
• Wall mounted - Easy Installation
• Outdoor sensing distance 60m, 100m or 200m.
• Anti-Interference with Light Filter
• Tamper Protection
• Wall hanging installation.
• False-Alarm resistant - prevent interference from birds and small pets.
MORE TYPES OF SENSORS ARE AVAILABLE UPON REQUEST TO SUIT OUR NEEDS !
32
Quick guide on how to activate and deactivate wireless accessories
Max. no. to be
Type Zone No. How to activate How to deactivate
programmed
1)【SET + password + ▲ or ▼ “Program sensor” + ENT 1) 【SET + password + ▲ or ▼
+ + Y Y + ENT + + X + ENT + ▲ or ▼ “Activate “Program sensor” + ENT + + Y Y + ENT +
Remote 00, 01 8 sensor” + ENT 】(The screen would say learning) + X + ENT + ▲ or ▼ “Delete sensor” + ENT 】
1. 2) Press on the remote twice successively, the host 2) The alarm host will beep once and press ESC to
LCD will display ”Success”; exit.
Wireless door 1) Same as above
4 Same as above
sensor 11~20 2) Trigger the door magnet sensor twice successively
Wireless Wide- 1) Same as above
Angle PIR sensor 4 2) Trigger the PIR sensor by pressing “Learning Emitting Same as above
21~30 Switch” on the panel twice successively
Wireless Curtain 1) Same as above
PIR sensor 4 2) Trigger the PIR sensor by pressing “Learning Emitting Same as above
11~20 Switch” on the panel twice successively
1) Same as above
Wireless Gas
4 2) Trigger wireless gas alarm by Same as above
detector 02~10
releasing gas, the host LCD will display “Success”
1) Same as above
Wireless Smoke
4 2) Trigger wireless smoke alarm by Same as above
Sensor 02~10
releasing smoke, the host LCD will display “Success”
1) Same as above
Remote Keypad
8 2) Press on keypad twice successively, the host LCD Same as above
00, 01
will display ”Success”
1) After connecting to the power, press the “learning”
switch on the side of the siren
2) Press key on the alarm host (not the remote) to
After connecting to the power, keep pressing the
sound off the siren, then disarm by using the alarm host
Wireless Indoor “Learning” switch on the side of the siren for 5
—— keypad【ESC + password + ENT 】, the alarm host will
siren N/A seconds and release, light on the siren flashes 2
beep twice to indicate the indoor siren has been
times and then off indicate successful deactivating
successfully disarmed.
3) the siren light will flash 5 times and then off indicates
successful activating
Wireless Outdoor
—— Same as wireless indoor siren Same as wireless indoor siren
Siren N/A
33
Common Problems and Solutions
Symptoms of Faults Possible Cause Solution
Incorrect insertion of SIM card.
SB-GL8088 GSM Network cannot be Check the SIM card placement.
SIM card with password.
detected (Fast signal LED flashing) Remove any password set in the SIM card.
SB-GL8088 SMS message cannot pass SIM card has junk messages that blocked the Clear any messages and contact numbers stored in the SIM
through to command the system. operation. card.
SB-LL8088 The alarm host goes off The telephone incoming line has not been connected
Connect the telephone incoming line well.
immediately after connected to the power or not well connected.
The alarm host can’t automatically record The record switch is not on; 1. Slide the record switch to “ON”;
or can’t record completely The Record key is being pressed while recording 2. Keep pressing the RECORD key while recording.
1. “Armed Away” mode: the alarm goes off when any sensor is
1. Caused by the functions of arm mode (Armed triggered;
The host does not alarm after the detector Away and Armed Home); 2. “Armed Home” mode: the alarm goes off when any sensor
is triggered in arm state 2. Have already setup time for Entry Delay or Exit in 1st Defense Line is triggered and it won’t alarm when any
Delay sensor in 2st Defense Line is triggered
3. Program to adjust the time for Entry Delay or Exit Delay
1. Open the sensor shells to install the batteries well and slide
1. Not connected to the power the power switch to “On”;
The PIR sensor doesn’t work
2. Port of the detector is in the power-down mode. 2. “5S”: detect once every 5 seconds;
“5MIN”: detect once every 5 minutes;
The host does not alarm after the new Failed to follow the operation instruction of “Adding Follow the operation instruction of “How to program” to activate
added wireless detector is triggered. and deleting sensors” to add the new wireless sensor the new wireless sensor
The PIR sensor flashes frequently in
Batteries are running out. Replace with new batteries in the same specification.
green.
The door magnetic sensor indicator
Batteries are running out. Replace with new batteries in the same specification.
flashes frequently in green after alarming.
34
The distance of the remote controller gets
Batteries are running out. Replace with new batteries in the same specification.
shorter.
The host does not alarm after the new Failed to follow the operation instruction of “Adding Follow the operation instruction of “How to program” to activate
added wireless detector is triggered. and deleting sensors” to add the new wireless sensor the new wireless sensor
Accessories