SMC Catalog Short
SMC Catalog Short
www.smcint.com
“The maximum compliance in the design of our products
meets the needs of customers and users worldwide. ”
SMC is proud to present in this catalog the widest range of products that exist on the
market for electrical test equipment in relay testing and for substations maintenance in
applications for generation, distribution, transmission and industry in general.
For more than 25 years SMC has been designing and manufacturing electrical test
equipment for the above electrical sectors. Our permanence in this highly technological
and competitive market, can be explained thanks to the constant application of working
principals, the company structure and products produced, making us successful during all
these years.
The Quality is the foundations of our company in all aspects and in all our company
departments; R & D, production, sales, and after sales support.
Quality in Design, guaranties that our equipment meets the demands that we impose and
what our customers expect.
Quality in Products, is obtained by taking care of the details during the entire production
process and by selecting the best material and components that are used in the
equipment.
Quality in Service, with immediate and permanent attention, technical and commercial
questions are answered by qualified and committed personal.
A maximum compliance in the design of our products meets the needs of customers and
users worldwide. All our products are flexible in their use, as we incorporate a very intuitive
manual control. SMC offers a range of products that meet the application required, which is
reflected by our satisfied customers who use our products.
At SMC we seek alternatives that make us better, more efficient, more competitive.
Therefore, we question every step in the process and every task, no matter how small it is.
Design and innovation are inside our DNA. Formula Innovation is a reflection of who we
are, and we have made it real with an unprecedented product: the Raptor.
www.smcint.com 3
Contents
Secondary injection equipment for relay testing 7
Mentor 12 Universal Relay Test Equipment 8
Configurations and applications 9
R O O T S Software 10
Smar t test tools (STT ) 10
P T E - 100 - C Current and voltage relay testing unit up to 250A 11
P T E - 100 - C P L U S Single Phase Relay test unit 12
P T E - 100 - C P R O Single Phase Relay test unit with an independent voltage module 12
P T E - 100 - V Single phase relay test set Voltage / Current 13
P T E - 50 - C E Single phase relay test set Current / Voltage 13
P T E - 50 - C E - P R O Single phase relay test set with voltage module 13
U N O Combination of the PTE-50-CE and PTE-100-V 14
PT E-F CG Battery Simulator 14
P T E - 300 - V Three phase relay test set Voltage / Current 15
P T E - 50 - C E T Three phase relay test set Current / Voltage 15
T R E S PTE combinations 16
Measurement Equipment 19
P M E - 500 - T R Circuit Breaker Analyzer 20
P M E -T C E Optional travel, speed and acceleration analysis plug-in module 21
GOOSEMeter One IEC 61850 GOOSE Sniffer 21
P M E - 20 - P H Phase Angle Meter 22
P T E - 30 - C H Por table Timer 22
P R I M E 600 Dynamic Micro-ohm Meter 23
Primary injection 25
Raptor System Multifunctional Primary Injection Test System 26
R A P T O R CV High current & high voltage injection. 28
T R I RA PTO R Three-phase primary current injection 28
L E T- 400/ R D / R D C Primary Injection Test Set up to 2,500 A . 29
L E T- 1000 - R D Primary Injection Test Set up to 6,250 A . 29
L E T- 2000 - R D / R D M Primary Injection Test Set up to 10,800 A . 29
L E T- 2010 - R D Primary Injection Test Set up to 13,000 A . 30
L E T- 4000 - R D Primary Injection Test Set up to 21,600 A . 30
L E T- 4000 - R D M Primary Injection Test Set up to 21,600 A . 30
L E T- 4000 - R High DC current injection set 30
P RO D U CT S S E L E CT I O N 31
The secondary injection equipment for relay testing has been the main activity of SMC. For this
reason, the extensive range of products comes from the experience obtained during the past 25 years.
Our tradition in the design and manufacturing of this type of equipment has enabled us to have a
complete range of equipment with different philosophies for the various applications and customers
who use relay test equipment.
The Mentor 12 incorporates the latest designs and concepts in test equipment, based on leading
edge technology. This revolutionary product, the most modern equipment of its class, fulfills the
requirements of the transmission departments and for the commissioning of new installations.
Unlike any other test equipment, both in power and features, the Mentor 12 can have up
to two, three phase systems in one unit, with all logical inputs and outputs required when
testing protection relays. This equipment continues the tradition of SMC in designing the most
complete equipment with sufficient, and reversible outputs, along with independent output
channels. The ability to upgrade the equipment with Plug and Play additions makes the Mentor
12 the most advanced equipment on the market.
The PTE-100-C is a single phase test set based on variac output regulation. The outstanding
features are; the smallest, lightest, highest power and easiest to use equipment of its kind on
the market. Its versatility is an essential tool for all types of relay tests.
The PTE electronic range of equipment is designed to serve the majority of relay applications
and can be combined with other equipment to expand the applications. These portable, robust,
equipment have electronic generated outputs and are a favorite with service companies, along
with the distribution and generation departments of the Utilities as they are adapted and
designed to meet their requirements. The characteristics and the functionality of this range of
products are not found anywhere else. Other unique benefit is the high power, both in current
and voltage, being able to test all types of relays, including electromechanical relays. The
reversibility in all output channels (current/voltage) and the external reference input, enables
this range to work with other equipment, including all other brands on the market, being the
most flexible test systems that can be found.
www.smcint .com 7
Mentor 12
U N I V E R S A L R E LAY T E S T E Q U I P M E N T
OPTIONS
MENTOR 12 GPS/IRIG - B RECEPTOR A P P L I C AT I O N S
The configuration software tool is included in the
DESCRIPTION Mentor 12 internal software, thus avoiding the use of
The Mentor 12 provides this synchronization by the an external computer, and allows to subscribe/publish
use of two alternatives of very GOOSE messages.
precise time reference inputs: GPS and IRIG / B. This option works through the RJ-45 connector,
A P P L I C AT I O N S which connects with the IEC-61850 bus and uses the
To initiate a state sequence or to execute a information contained in the GOOSE messages as logic
COMTRADE file in a defined time and with a inputs. It is also able to broadcast GOOSE messages that
accuracy of microseconds. R E C E PTO R G P S acts as logic outputs, exactly in the same way that the
current Mentor 12 electrical I/O works, but avoiding the
C H A RACT E R I S T I C S I E C - 61850 G O O S E M O D U L E
wiring of the I/O to the relay inputs and outputs.
The GPS and IRIG / B can be installed in any existing DESCRIPTION
or future Mentor 12, without needing to send back C H A RACT E R I S T I C S
The option Mentor IEC 61850 is a GOOSE message
the unit to factory. The IEC 61850 option can be installed on any
interface board based on IEC 61850 protocol. The
existing or future Mentor 12 at any time.
PCB board can be installed in the control bus of any
Mentor 12.
8 www.smcint.com
M E N T O R 12 C O N F I G U R AT I O N S A N D A P P L I C AT I O N S
3 voltage (0-150 V or 0-5 A) + 3 current Single- and three-phase testing of any type of relay, transducers and meters. Up to 600 VA
3V + 3I 6
channels (0-25 A), with 100 VA each. total output power. Full-range transient playback. Provides 6 currents.
4 voltage (0-150 V or 0-5 A) + 3 current Adequate for synchronizing relays. Direct three-phase testing with neutral voltage
4V + 3I 7
channels (0-25 A), with 100 VA each. elements and a current up to 5 A. Capable for testing three phase differential relays.
4 voltage (0-150 V or 0-5 A) + 4 current A fourth current supply up to 25 A for devices with neutral element. Single phase test up to
4V + 4I 8
channels (0-25 A), with 100 VA each. 100 A with 400 VA of power. Testing single phase differential relays with up to 25 A.
3 voltage (0-150 V or 0-5 A) + 6 current Three- phase electromechanical relays. Direct testing of differential relays with triple
3V + 6I 9
channels (0-25 A), with 100 VA each. windings, maintaining the connection class. Up to 50A current per channel.
Calibration of low voltage measurement converters and energy meters. Fault tests of high
6 voltage (0-150 V or 0-5 A) + 3 current
6V + 3I 9 impedance relays, directional detection of differential neutral with high voltage setting
channels (0-25 A), with 100 VA each.
and moderate current setting.
4 voltage (0-150 V or 0-5 A) + 6 current Single- and three-phase testing with high current settings Differential relay testing.
4V + 6I 10
channels (0-25 A), with 100 VA each. Provides up to 10 currents.
AC RA N G E: 0 - 150 V / 0 - 5 A 0 - 25 A
D C RA N G E: 0 - 212 V / 0 - 5 A 0 - 25 A
R E S O L U T I O N: 5 mV / 0,5mA
O U T P U T C H A N N E L C A PA C I TY : 1- 6
A C C U R A CY : ±0,1%
D I S TO RT I O N: ±0,1%
P ROT E CT I O N: All outputs are electronically protected both thermal and overload S TA RT S C R E E N
RO OT S T E S T S C R E E N F A U LT F U N CT I O N CO N F I G U RAT I O N RA M P CO N F I G U RAT I O N
www.smcint.com 9
ROOTS Software
DESCRIPTION routines and report definitions. easy to understand.
ROOTS (Relay Object-Oriented Test System) - Database management functions for the import/ - The database is organized by devices (IED), and the
provides the best solution to the testing of today’s export of device (relay), test definitions and results various test modules can be added to each device.
multifunctional IEDs by performing accurate fault between databases. - Specific modules are available such as Distance,
calculation, sequential test execution, and reporting - Ability of using formulas instead of fixed values Differential, or Overcurrent, and also imports RIO files.
automatically. when entering test values, settings, options or - Each test module contains a set of testing tools
ROOTS is an optional product for PC-operation of other data. (click sequence, search, reclosing, breaker failure, etc.).
SMC’s Mentor 12 and TRES relay test sets. ROOTS - Direct import of RIO relay description files supplied - In summary, substation/s overall test procedures
is developed using the latest Microsoft .NET® by a number of relay manufacturers. can easily be built, can be repeated for
technology and is available for 32-bit and 64-bit - Intuitive graphical zone and elements maintenance testing, and also used as templates
Windows XP or later platforms. Characteristics Editor, with pre-defined Templates. for similar substations with minimum adjustments,
ROOTS includes also a powerful graphical - Modular architecture, different optimized test which saves considerable time.
editor, which allows representing the operating modules for each protection function.
characteristics of IED in minutes, easing the test - Modular pricing, ROOTS can be purchased with
process. It includes a click & test method and also one or more functional modules, providing a price
automatic generation of the test points list, with optimized solution.
immediate test report generation. - Free updates, No other product in its class offers
free lifetime updates and the possibility of being
upgraded (in software and in hardware) by the user
C H A RACT E R I S T I C S
himself.
-The best solution to the testing of today’s
multifunctional IEDs. A P P L I C AT I O N S
- Spans the testing from the relay to its interactions ROOTS implements an intuitive and friendly
with the whole protection scheme. interface for quick and accurate test configuration.
- Accurate fault calculation and sequential test - Allows the configuration and storage in the
execution. database of the different devices, the test modules,
- Automatic, customized and exportable Reporting. test results and test reports.
- Roots storage files are self-contained databases: - Test routines and report definitions are saved
relay data, characteristics, custom formulas, test according to a simple hierarchy that is flexible and
10 www.smcint.com
PTE-100-C
C U R R E N T A N D V O LTA G E R E LAY T E S T I N G U N I T U P T O 250 A
OPTIONS
PT E-F CC PT E-F C L / PT E-F C N Characteristics
- Connected directly to monitor taps.
- Easily mounted and trasported inside the unit.
- Dimensions:
90 x 120 x 60 mm / 0.4 kg.
3½ x 5 x 2½ in. / 1 lb
Load Option Variable Voltage, Frequency and Phase Shifter Option PT E-F C F
Applications Applications
- Increase load value. - Relay test which require variable frequency and
- Improves current regulation. phase angle, and independent voltage.
- Improves output distortion. - Can be used with any existing PTE-100-C.
- Obtain different angle values up to ±90°, enabling
Characteristics
to test directional relays.
- AC voltage output up to 140 V. Variable Voltage Option
Characteristics - Frequency output from 40-70 Hz.
- Resisters: 0.5, 1, 2, 25, 50, and 100 ohms. - Variable phase angle 0-359.9°. Applications
- Mounted in top cover. - Easily mounted in the top cover. Enables to regulate the fixed voltage output of 110
- Built-in LCD display (PTE-FCN). V AC which is common in all the PTE-Range.
PT E-F C B Characteristics
PT E-F C E - Regulation range: 10 to 120 V.
- Maximum current: 0.3 A.
- Designed to be connected directly.
- Dimensions:
90 x 120 x 60 mm / 0.8 kg.
3½ x 5 x 2½ in. / 2 lb.
MCB Test Option
External Timer Start Option
Characteristics
To test MCB’s up to 250 A. Mounted in the cover of Applications
the PTE-100-C enables field testing of MCB’s of one Starts timer with external contacts, (NO) normally
or more poles up to 250 A. open/(NC) normally closed.
www.smcint.com 11
PTE-100-C Plus
S I N G L E P H A S E R E LAY T E S T U N I T
PTE-100-C Pro
S I N G L E P H A S E R E LAY T E S T U N I T W I T H A N I N D E P E N D E N T V O LTA G E M O D U L E
DESCRIPTION A P P L I C AT I O N S
The PTE-100-C Pro combines the basic unit PTE- The PTE-100-C Pro has the same applications as the
100-C with the voltage supply module PTE-FCN. This PTE-100-C Plus, although its use is much easier due
is incorporated in PTE-100-C cover lid, and allows, to the LCD display incorporated. Furthermore this
regulated AC voltage, frequency, and phase angle. module can be used in combination with any other
The values which are presented in the LCD display PTE-Range equipment.
are highly accurate, easy to read, and independent of
C H A RACT E R I S T I C S
the injection made by the PTE-100-C base unit.
The display shows continuously the phase difference The characteristics of PTE-100-C Pro are the
between the voltage and the current injected, and same as the PTE-100-C Plus, with the following
can be adjusted during the test with an accuracy of specifications:
0.1º. This facilitates the test for directional relays
MEASURES
or reclosers and synchronizing relays, etc. The
protection tests based on frequency are simple and Range Resolution Accuracy
12 www.smcint.com
PTE-100-V
S I N G L E P H A S E R E LAY T E S T S E T V O LTA G E / C U R R E N T
PTE-50-CE
S I N G L E P H A S E R E LAY T E S T S E T C U R R E N T / V O LTA G E
PTE-50-CE PRO
S I N G L E P H A S E R E LAY T E S T S E T W I T H V O LTA G E M O D U L E
DESCRIPTION F C N C H A RACT E R I S T I C S
Using the optional PTE-FCN module. - 30-VA output power
Additional independent output channel with variable - Adjustable voltage: 0.0 – 140.0 V
voltage, frequency and phase angle. Extends the - Adjustable phase angle: 0.0 – 359.9º.
PTE-50-CE applications to protective elements - Adjustable frequency: 40.0 – 70.0 Hz
with two voltage inputs or one current and one - Digital high-contrast LCD display
voltage input (e.g. directional, distance, overcurrent, - Installed inside the lid of the PTE-50-CE
synchronisation, frequency relays, etc.) - Dimensions:
200 x 300 x 200 mm. / 15.5 kg.
8 x 12 x 4 in. / 35 lb.
www.smcint.com 13
UNO
C O M B I N AT I O N O F T H E P T E - 50 - C E A N D P T E - 100 - V
DESCRIPTION C H A RACT E R I S T I C S
The combination of PTE-50-CE and PTE-100-V - 2 reversible output channels in current or voltage,
is used for testing single phase relays and are completely isolated, with individual phase angle
interconnected via the PTE-BUS. To control both control.
units simultaneously the equipment incorporates - Output power 100 VA in each channel
master/slave control for all outputs and levels. - Variable voltage up to 300 V and variable current
These small, lightweight units incorporate a built- up to 50 A.
in timer (PTE-50-CE) and a frequency generator - Variable phase angle from 0 - 360º.
(PTE-100-V). Each equipment retains their individual - Variable frequency from 40 to 420 Hz.
characteristics and can be used together or - Internal program to ramp frequency.
separately for single and three phase tests. - Built-in timer with a 1 ms resolution.
- Dimensions:
A P P L I C AT I O N S
200 x 300 x 200 mm. x 2 / 13.5 + 13.5 kg.
- Testing of all types of single phase relays whether
8 x 12 x 8 in. x 2 / 30 + 30 lb.
they be electromechanical or digital, including
differentials, synchronizing, directional, current, and See the specific characteristics of each unit in the appropriate
voltage. sections of this catalog.
PTE-FCG
B AT T E RY S I M U LAT O R
DESCRIPTION C H A RACT E R I S T I C S
The Battery simulator PTE-FCG is a simple and - Voltage output: 48/125/250 V DC.
compact DC voltage to supply static and electronic - Power: 60 W in each output.
relays when being tested. The equipment has a - Designed to be mounted in the top lid of the
voltage supply with 3 DC output levels. PTE Range of equipment or can be used as an
independent unit.
A P P L I C AT I O N S
- Dimensions:
- Provides an auxiliary DC voltage supply to the relay
110 x 180 x 60 mm. / 4 kg.
under test.
4 x 7 x 2 in. / 9 lb.
14 www.smcint.com
PTE-300-V
T H R E E P H A S E R E LAY T E S T S E T V O LTA G E / C U R R E N T
PTE-50-CET
T H R E E P H A S E R E LAY T E S T S E T C U R R E N T / V O LTA G E
www.smcint.com 15
TRES
P T E C O M B I N AT I O N S
OPTIONS
P T E - 12 Characteristics RO OT S S O F TWA R E
- Regulation range: 10 to 120 V. Making the difficult easy
- Maximum current: 0.3 A. Roots (Relay object-oriented test software) is the
- Designed to be connected directly.
SMC response to the increasing complexity of the
- Dimensions:
90 x 120 x 60 mm / 0.8 kg. management and diverse testing methods with the
3½ x 5 x 2½ in / 2 lb. modern numerical IEDs or protective relays.
Roots has sophisticated preprogrammed features
RS-232 Interface / PTE BUS PT E-G P S
allowing the user to compose a complete test
Applications protocol by select them from a list. Each IED is
- Enables the control of the PTE equipment from a registered in the database along with the
PC through a RS-232 serial port. test list and with its historical results Roots can
- Extraordinary flexibility as it can control up to 6 export data to a standardized information system
PTE equipment. for your test report in any format. Roots provides the
Characteristics GPS Synchronizer engineer an innovative protective paradigm which
- Power is automatically supplied by the connected allows to express the testing process on the terms
equipment. Applications of each type of protection (impedance, distance,
- Includes all cables and connectors required. This option allows the initial synchronization of
differential, current symmetrical components etc.)
- Includes the PTE-COM control command manual. faults, previously recorded to be played back by
freeing you from complicated calculations, saving
- Dimensions: the PTE equipment, with an accuracy of less than 1
90 x 120 x 60 mm. / 0,5 kg. time and eliminating errors.
microsecond.
3½ x 5 x 2½ in. / 1 lb. To establish the moment of injection, the
EUROFAULT software can be programmed to begin As well a powerful graphical editor allows to
PT E-F C F
the test at the required time. represent the IED operating characteristics in
minutes thus facilitating the understanding of the
Characteristics
tests, using the manual click & test methods
- Accuracy: <±1µs.
or allows the program to select test points and
- Time until ready for operation: typically 3 min.
- Power supply: via PTE-BUS. generate these automatically.
- Power consumption: 2W. See more information about Roots on page 16.
Variable Voltage Option - Accessories: GPS antenna, PTE cable, box.
- Dimensions:
APPLICATIONS
- 90 x 120 x 60 mm. / 0.5 kg.
Enables to regulate the fixed voltage output of 110
- 3½ x 5 x 2½ in. / 1 lb.
V AC which is common in all the PTE-Range.
16 www.smcint.com
RELAY TYPES THAT CAN BE TESTED
www.smcint.com 17
Measurement
Equipment
M E A S U R E M E N T E Q U I P M E N T F O R S U B S TAT I O N
MAINTENANCE AND COMMISSIONING
In the constant search of satisfying our customer’s needs and requirements, SMC found that many of
our customers require modern and practical measuring test equipment, especially in the maintenance
and commission departments, incorporating the characteristics and functions required by them.
SMC has been designing innovative and revolutionary products for electrical measurement tests.
Our independent and traditional concepts in product and design, focus on the necessities of our
customers.
Portability. Reduced size, weight, and robust which is essential for field use.
Autonomy. Almost all this range of products has internal rechargeable batteries incorporated in
the equipment. Therefore can be used without a voltage supply which is not always available in
commissioning and substation work.
Integration. The use of microprocessors and other technical advances, enables the equipment to
be multifunctional, as well as, avoiding errors and saving time.
Reliability and accuracy. The equipment is designed and produced with the latest technology and
components, assuring the accuracy and reliability.
The Circuit Breaker Analyzer, which incorporates a three phase contact resistance measurements,
is one of the example that EuroSMC incorporates into our designs. All the new equipment
designed by us in the past years have been leaders in the market.
The new GOOSEMeter is the answer to the tasks and applications that are required for the new
substations, which demand new tools to make the work easier and more efficient.
www.smcint .com 19
PME-500-TR
C I R C U I T B R E A K E R A N A LYZ E R
C H A RACT E R I S T I C S
- 3 timing inputs for the three main contacts, 0.1ms
resolution.
- 2 isolated auxiliary binary inputs, with a capacity
for dry contacts or voltage signals up to ±360 V DC,
0.1ms resolution. O PT I O N A L S E T O F F A S T M E A S U R E M E N T C LA M P S CO N N E CTO R D E TA I L S
- Measures and records the Coil currents
simultaneously (open and closed), with 1ms
resolution up to 50 A DC (auto range).
- Connection to the breaker by means of a special
multipole cable connector or by 4 mm input taps.
G RA P H I CA L P R E S E N TAT I O N O F R E S U LT S. N U M E R I CA L P R E S E N TAT I O N O F R E S U LT S. C U S TO M R E PO RT W I T H T H E CO M PA N Y LO G O.
20 www.smcint.com
PME-TCE
O P T I O N A L T R AV E L , S P E E D A N D A C C E L E R AT I O N A N A LY S I S P L U G - I N M O D U L E
A P P L I C AT I O N S T RA N S D U C E R S
The PME-TCE adds travel, speed, acceleration, Movement sensors and mechanical adapters.
and wipe data and graphics to the circuit breaker
P M E - AT K
analysis report. This small module is powered from
the PME-500-TR and provides connections for one
analogue and three digital transducers. Results from
multiple tests are saved in its flash memory and
then downloaded to the PC by means of the USB
connection.
Rotary Transducer Kit, full angular measurement kit
C H A RACT E R I S T I C S
consisting of digital angular encoder, articulated arm
- Digital inputs: 3 single-ended TTL, 5 V, 100 mA.
with magnetic stand, set of four shaft adapter
- Analogue input: 7.5 V, 10 mA. bushings and hex key wrench.
- Communication: USB, PME BUS.
- Sampling frequency: 5 kHz per channel. P M E - LT 50 A
- Maximum recording time: 2 seconds.
- Dimensions:
148 x 89 x 25 mm. / 0,4 kg.
6 x 3½ x 1 in. /1 lb.
GOOSEMeter One
I E C 61850 T R A F F I C M O N I T O R DESCRIPTION - GOOSE monitoring with online indication of the
Once connected to the substation’s IEC 61850 status change.
network, the GOOSEMeter One will immediately - Event time, with microsecond resolution, of the last
identify GOOSE messaging frames, will group them in event.
their corresponding data sets and will visually display - Identification and checking of GOOSE messages
status, along with the historical list of changes.
the update activity on the screen.
- Shows in detail the list of data contained in the
The GOOSEmeter one is a read only device, so your
GOOSE message.
network will remain safe against unwanted input.
- Real-time inspection of IEC-61850 dataset lifecycle.
The collected data will be permanently stored in - GOOSE Filtering capability for monitoring only the
the device’s flash memory for later download from a selected data of interest.
Windows PC via the built-in USB port. - Templates editor, enables to personalize data names
The GOOSEMeter One’s operation is easy and for easier identification.
intuitive, thanks to its touch sensitive TFT display - Discriminates datasets with different destination
and the push/rotary encoder for fast navigation and MAC address.
selection. - Shows datasets with more than 64 data.
- Firmware can be updated by internet.
C H A RACT E R I S T I C S - High definition Touch Screen.
- No configuration, plug & run. - GOOSESync for PC: Connectivity with an external
- Test in service. computer, via USB, for downloading, analysis, and
- Read-only instrument. quick edition of templates.
- Not PC dependent.
- Dimensions:
- USB storage. 110 x 184 x 26 mm. / 400 gr.
- Handheld device to use in reduced spaces. 4 x 7 x 1 in. / 1 lb.
- Substation’s cabling verification.
- GOOSE message contents analysis.
www.smcint.com 21
PME-20-PH
PHASE ANGLE METER
DESCRIPTION C H A RACT E R I S T I C S
The phase angle meter is designed to measure the - Phase angle accuracy: ±0.1°.
phase angle, but also measures frequency, power - Voltage input: 0.2 to 500 V RMS direct.
factor, and it has an analogical scale that can be used - Current input: 0.1 to 25 A RMS direct.
as a synchronoscope. - Selected Measurement Modes:
• Phase Angle displayed as ±180°.
A P P L I C AT I O N S
• Phase Angle displayed as 0 - 360°.
- Measures the phase angle between two Voltages,
- Frequency: 40 to 500 Hz.
two Currents, or Voltage-Current.
- Power Factor: 0 to ±1 and indicates phase angle
- Measures Frequency.
quadrant.
- Measures Power Factor.
- Battery Powered.
- Synchronoscope.
- Reduced size and weight.
- In general, for Maintenance in Transmission and
- Dimensions:
Distribution Systems, all well as industrial or
226 x 115 x 45 mm. / 650 gr.
commercial centers.
9 x 4½ x 2 in. / 1½ lb.
OPTIONS
- External adapter up to 750V RMS.
- Current clamp 1000/5A
PTE-30-CH
P O R TA B L E T I M E R
DESCRIPTION F U N CT I O N S:
This chronometer has been designed as an accessory - Start/Stop: time between two events.
to our injection instruments to test protective - Pulse: measures the time of a signal pulse.
Relays. The PTE-30-CH can also be used as a stand- - Frequency: Reads the signal frequency at the input
alone instrument taps.
- Accuracy: ±0.01% ±1ms.
A P P L I C AT I O N S
- Dimensions:
- Measures the trip time in protection relays and in
190 x 100 x 40 mm. / 1 kg.
general the lapse time between two events.
8 x 4 x 2 in. / 2.2 lb.
- Measures the time duration of electrical signals.
- Measures frequency.
C H A RACT E R I S T I C S
- Measurement range: 3 modes
- S Mode: 00.000-99999s.
- Cycle Mode: 0000.0-9999.9 Cycles.
- Frequency Mode: 20.000-4000.0 Hz.
22 www.smcint.com
Prime 600
600 A D Y N A M I C M I C R O - O H M M E T E R
DESCRIPTION at the beginning of any test, the equipment checks
The Prime 600 is a micro-ohm meter that integrates for proper connectivity of the system, warning of
both the contact resistance and the dynamic possible connection mistakes; for increased safety,
resistance measurement (DRM) as stand-alone unit; the Prime 600 demagnetizes the connected load at
the dynamic resistance test, which is essential in the end of each measurement.
analyzing the wear of the arcing contacts in SF6 and
C H A RACT E R I S T I C S
vacuum breakers, is a function never found before
- Dynamic Resistance Measurement
in micro-ohm meters, so that with the Prime 600 is
- Dual ground operation
not required to combine several equipment for the
- Automatic de-magnetization function
complete static and dynamic resistance analysis,
- Alert on connection mistakes
becoming an ideal option for circuit breaker testing. - Touch-sensitive graphical display
The Prime 600 draws the DRM time/resistance - Pre-defined test modes
curve that describes the resistance changes on the - Built-in thermal printer
measured spot throughout a few milliseconds, for - Removable USB storage
detecting contact anomalies and wear; the analysis - PC download and reporting
of the relevant characteristics and values of this - Sturdy, water proof ABS casing, IP67
curve is an effective diagnostic way of the internal - Temperature normalization
condition of the breaker contacts, and reveals
potential problems related to the arcing contact
Power supply: 115/230 Vac – 50/60 Hz
condition without having to open the chamber.
The Prime 600 micro-ohm meter provides an easy Dimensions: 47 x 35.7 x 17.6 cm
and intuitive use with touch screen and several
Weight: 13.5 kg.
pre-defined test modes, reducing the testing time;
OPTIONAL ACCESSORIES
C O N TA C T- L E S S T E M P E R AT U R E
SENSOR
D U A L G R O U N D C U R R E N T C LA M P
www.smcint.com 23
Primary injection
P R I M A RY I N J E C T I O N T E S T E Q U I P M E N T
The maintenance and substation departments traditionally have found limitations when selecting
primary injection test equipment. Either the equipment is a home made brand with low reliability,
poor accuracy at a low price, or a small selection of equipment with the accuracy and quality required,
but at high price.
SMC primary injection sets are a perfect solution, as the range of products are situated between
the two options previously mentioned. The primary injection equipment manufactured by SMC
is a large range of products that meet the power, current, and accuracy required for this type of
testing.
The Raptor System sets a new standard in the design of primary injection test equipment.
Leading edge technology and engineering have been combined to achieve a small, but powerful
and very portable equipment. This unit provides safer working conditions and also makes
electrical maintenance more efficient and accurate, taking workability in Primary injection test to
levels never seen up till now.
The LET range of primary injection test equipment are perfectly adequate to test current
transformers, busbars, circuit breakers, switchboards, complete system such as transformers-
relays, and interconnections, with the adequate technology and accuracy at an economic price.
The large product range enables the selection of appropriate equipment required for the
application required.
www.smcint .com 25
Raptor System
M U LT I F U N C T I O N A L P R I M A RY I N J E C T I O N T E S T S Y S T E M
26 www.smcint.com
Raptor System Components
Raptor Master
C H A RACT E R I S T I C S DESCRIPTION
3 kVA output power Every Raptor System needs one Master unit with the Raptor HH commander
Handheld controller connection connected. This basic configuration is named Raptor C-05. It can be used stand
High current up to 9600 AAC alone for high current testing and for most measurement applications. Add Current
Voltage up to 200 VAC slaves to increase the injection power or one Voltage slave for moderate-to-high
Current, voltage, frequency and
AC voltage test jobs.
phase angle measurement inputs.
C H A RACT E R I S T I C S DESCRIPTION
8 kVA power increase The current slave increases the Master unit’s compliance voltage for heavily
15000 A max current demanding current applications. Especially appropriate for long injection cables
IrDA link or for current values greater than 9600 A. Up to three slaves can be added to one
Master for configurations Raptor C-15, C25, and C35 respectively. Current slaves
communicate with the master unit only via the built-in infrared link.
Raptor HV
C H A RACT E R I S T I C S DESCRIPTION
AC Voltage up to 2000 V Expands the Raptor System’s test capabilities to applications requiring up to
Built-in ammeter 2000 VAC injection (power transformers, insulation tests, Step & Touch Voltage
Built-in alert buzzer measurement and more). Pre-defined test templates included in the Raptor’s
Powered and controlled from the standard repertoire. Optional accessories available for special applications and
Raptor Master unit
added safety measures. The Raptor CV-05 configuration includes one Raptor C-05
system and one Raptor HV slave.
Optional Accessories
U LT R A - F L E X I B L E S I L I C O N H I G H C U R R E N T C LA M P S C A B L E G R O U P I N G P LAT E S
C O AT E D C A B L E
Copper braid 120 mm2 in 3-m, 6-m and Provide safe, solid and low resistance The best possible attachment of paralleled
9-m cut length, finished with drilled press connections for high current cables to current cables to the tested device. Available
terminals. Especially suited to leverage the overhead lines. in pairs for up to six cables per plate.
Raptor’s multi-turn feature.
P O LA R I TY T E S T E R H I G H V O LTA G E S A F E TY S T E P & T O U C H V O LTA G E
MEASUREMENT
Quickly locate swapped connections in any AC Rotating warning light and mushroom type Normalized 25-kg electrodes and cable reels
installation. Pre-defined procedure included in emergency stop. Driven automatically by the for Step and Touch Voltage measurement with
the Raptor’s standard template set. Raptor HV upon test start / stop. the Raptor HV.
www.eurosmc.com 27
RAPTOR CV
H I G H C U R R E N T & H I G H V O LTA G E I N J E C T I O N
A P P L I C AT I O N S C H A RACT E R I S T I C S
- Primary overcurrent testing of circuit breakers. - Up to 9500 A AC output current.
- Re-closer testing. - Up to 2000 V AC output voltage.
- Current and voltage transformer evaluation. - Stabilized output.
- Knee point calculation and graphic. - Outstandingly portable.
- Insulation testing. - Touch screen user interface.
- Testing of voltage sensors and converters. - Factory- and user-defined test templates.
- Step & Touch voltage measurement. - PC download and reporting.
- Internet connection.
TRIRAPTOR
T H R E E - P H A S E P R I M A RY C U R R E N T I N J E C T I O N
A P P L I C AT I O N S C H A RACT E R I S T I C S
- Substation commissioning - Three current outputs at 0º-120º-240º
- Three-phase primary switchgear testing - Up to 9500 Aac
- 3 kVA output power per phase
- Stabilized output
- Outstandingly portable
- Touch screen user interface
- Units can be used separately
28 www.smcint.com
LET-400 / RD / RDC
A C C U R R E N T I N J E C T I O N U P T O 2500 A
A P P L I C AT I O N S C H A RACT E R I S T I C S
- Primary current injection. - Permanent current up to 400A.
- Substation and transform center commissioning. - Instantaneous current up to 2500 A.
- LV, MV and HV switchgear testing. - 1 kVA output power.
- Thermal protection testing. - Four selectable output taps.
- Current transformer evaluation. - Automatic overload protection.
- Built-in digital ammeter (RD and RDC models).
- Built-in digital chronometer (RD and RDC models).
- Variable 0-220 V AC an DC voltage output
Photo: LET-400-RDC (RDC model).
- Auxiliary DC power source up to 220V (RDC model).
LET-1000-RD
A C C U R R E N T I N J E C T I O N U P T O 6250 A
A P P L I C AT I O N S C H A RACT E R I S T I C S
- Primary current injection. - Permanent current up to 1000A.
- Substation and transform center commissioning. - Instantaneous current up to 6250 A.
- LV, MV and HV switchgear testing. - 2 kVA output power.
- Thermal protection testing. - Three selectable output taps.
- Current transformer evaluation. - Automatic overload protection.
- Built-in digital ammeter.
- Built-in digital chronometer.
LET-2000-RD / RDM
A C C U R R E N T I N J E C T I O N U P T O 10800 A
A P P L I C AT I O N S C H A RACT E R I S T I C S
- Primary current injection. - Permanent current up to 2000A.
- Substation and transform center commissioning. - Instantaneous current up to 10800 A.
- LV, MV and HV switchgear testing. - 4 kVA output power.
- Thermal protection testing. - Four selectable output taps.
- Current transformer evaluation. - Automatic overload protection.
- Built-in digital ammeter.
- Built-in digital chronometer.
- Two separately portable units.
- Motorized regulation in RDM model.
www.smcint.com 29
LET-2010-RD
P R I M A RY I N J E C T I O N T E S T S E T U P T O 13,000 A
A P P L I C AT I O N S C H A RACT E R I S T I C S
- Direct and motor overload relay test. - Permanent current up to 2000 A 6 kVA in 3 ranges.
- In general, primary tests including the complete - Maximum current output up to 13 kA.
loop, such as current transformer, cables, protective - Made up of two units.
relays and circuit breakers. - Built-in digital ammeter 0.5% accuracy.
- Built-in digital timer resolution 1 ms.
- Thermal and short-circuit protection.
LET- 4000-RD
P R I M A RY I N J E C T I O N T E S T S E T U P T O 21,600 A
A P P L I C AT I O N S C H A RACT E R I S T I C S
- Direct and motor overload relay test. - Permanent current up to 4000 A, 8 kVA in 4 ranges.
- In general, primary tests including the complete - Maximum current output up to 21,6 kA.
loop, such as, current transformer, cables, protective - Made up of two units.
relay and circuit breaker. - Built-in digital ammeter 0.5% accuracy.
- Built-in digital timer resolution 1 ms.
- Thermal and short-circuit protection.
LET- 4000-RDM
P R I M A RY I N J E C T I O N T E S T S E T U P T O 21,600 A
A P P L I C AT I O N S C H A RACT E R I S T I C S
- Direct and motor overload relay test. - Permanent current up to 4000 A, 8 kVA in 4 ranges.
- In general, primary tests including the complete - Maximum current output up to 21,6 kA.
loop, such as, current transformer, cables, protective - Made up of 2 units, control and power unit.
relay and circuit breaker. - Built-in digital ammeter 0.5% accuracy.
- Built-in digital timer resolution 1 ms.
- Thermal and short-circuit protection.
- Motorized Variac.
LET-4000-R
H I G H D C C U R R E N T I N J E CT I O N S E T
30 www.smcint.com
Product Selection
RA P TO R S Y S T E M M O D E L S A N D C H A RACT E R I S T I C S
P R I M A RY C U R R E N T I N J E CT I O N
Max. (A) Permanent Max. (A) 3 minutes Max. (A) 3 seconds Voltage Range (1 turn)
Raptor C-05 and CV-05 3800 A/ 3 kVA 7500 A/3 kVA 9500 A/2.55 kVA 1.2 - 0.22 V
Raptor C-15 and CV-15 3800 A/ 8.2 kVA 7500 A/11.5 kVA 15000 A/3.9 kVA 2.8 - 0.26 V
Raptor C-25 3800 A/ 13.3 kVA 7500 A/19.7 kVA 15000 A/13 kVA 4.4 - 0.87 V
Raptor C-35 3800 A/ 18.4 kVA 7500 A/28 kVA 15000 A/22 kVA 6 - 1.48 V
T H R E E-P H A S E I N J E CT I O N
Max (A) Permanent Max (A) 3 minutes Max (A) 3 seconds Voltage Range (1 turn)
TriRaptor 3800 A/ 3 kVA 7500 A/ 3 kVA 9500 A/ 2.55 kVA 1.2 - 0.22 V
H I G H V O LTA G E I N J E C T I O N
Max. (A) Permanent Max. (A) 3 minutes Max. (A) 3 seconds Voltage Range
L E T RA N G E M O D E L S A N D C H A RACT E R I S T I C S
LET-400 1 kVA 10 A,50 A,200 A,400 A 400 A 600 A 800 A 1,1 kA 1,4 kA 2,5 kA
LET-400-RD 1 kVA 10 A,50 A,200 A,400 A 400 A 600 A 800 A 1,1 kA 1,4 kA 2,5 kA
LET-400-RDC 1 kVA 10 A,50 A,200 A,400 A 400 A 600 A 800 A 1,1 kA 1,4 kA 2,5 kA
LET-1000-RD 2 kVA 250 A,500 A,1000 A 1 kA 1,5 kA 2,25 kA 2,25 kA 2,75 kA 6,25 kA
LET-2000-RD 4 kVA 250 A,500 A,1000 A,2000 A 2 kA 2,4 kA 3,6 kA 4,8 kA 6 kA 10,8 kA
LET-2000-RDM 4 kVA 250 A,500 A,1000 A,2000 A 2 kA 2,4 kA 3,6 kA 4,8 kA 6 kA 10,8 kA
LET-4000-RD 8 kVA 500 A,1000 A,2000 A,4000 A 4 kA 4,8 kA 7,2 kA 9,6 kA 12 kA 21,6 kA
LET-4000-RDM 8 kVA 500 A,1000 A,2000 A,4000 A 4 kA 4,8 kA 7,2 kA 9,6 kA 12 kA 21,6 kA
LET-4000-R 8 kW 4000 A 4 kA DC 5 kA DC
Available
Not available
www.smcint.com 31
ETP and EDA III
Systems
P R E D I CT I V E M A I N T E N A N C E I N POW E R T RA N S F O R M E R S
A N D E L E C T R I C A L R O TAT I N G M A C H I N E S
The ETP system is a set of equipment orientated to predictive maintenance in power transformers.
The objective of all the equipment that makes up the system of predictive maintenance of transformer
and rotary machines is to optimize the maintenance costs and to detect any faults before they occur.
Also to manage the status of the machine to avoid and minimizing any down time.
The basic elements that are common to all the equipment are:
- Common control elements.
- Specific software for each application.
- Easy to follow, guided by software.
- Automatically stores and manages test results.
- Tendency analysis.
- Modular system easy to transport.
- The results of the test in numeric values and graphically displayed, are automatically saved.
When the test is finalized you can print and save test results for further analysis.
- The advantage of the system, and especially with three phase transformers with tap changers,
gives quick measurement results, obtaining simultaneously the simple and compounded
values with external correction factors such as temperature. Therefore achieving savings in the
test time not only the measurement time, but also with results management and test report
generation.
32 www.smcint.com
ETP-1
T H R E E - P H A S E T R A N S F O R M E R T U R N S R AT I O M E A S U R E M E N T
DESCRIPTION C H A RACT E R I S T I C S
The ETP-1 module determines the turn ratio on the - The connection to the transformer taps is guided
three phases of power and distribution transformers from the computer to avoid connection errors.
and autotransformers of any type by applying a test - Enables to select the number of the tap changer
voltage on the high-voltage winding and measuring positions to be measured, as the software informs
the resulting voltage on the low-voltage winding. the position that should be measured each time.
- For each tap changer position, a three phase
A P P L I C AT I O N S
automatic measurement is performed. It is not
The ETP-1 equipment measures the following:
necessary to change the connection to the
- Actual turn ratio for each position of the tap
transformer taps.
changer.
- The no load test current waveform is presented on
- No load current and power, at the test voltage.
the computer screen. It detects possible problems
- Polarity.
in the iron core.
- Automatically calculates results according with the
- The test time for each three phase test position is
connection group.
less than 10 seconds.
- Automatically creates a graphic comparison
- The measuring range has a ratio between; 1:1 to
between the theoretic values and the values
3000:1.
measured during the test for each tap position.
- Dimensions:
The ETP-1 can detect the following:
400 x 450 x135mm. /13 kg.
- Problems in the tap changer.
16 x 19 x 5 in. /29 lb.
- Problems in the coils.
- Winding short-circuit.
- Defective contacts.
- Open circuits.
ETP-2
R E C O V E RY V O LTA G E A N D I N S U LAT I O N M E A S U R E M E N T
DESCRIPTION C H A RACT E R I S T I C S
The ETP-2 module measures the recovery voltage - Fully automatic Recovery Voltage test in all the test
on power and distribution transformers and cycles of voltage application and discharge of the
autotransformers of any type with insulation and measurement acquisition.
oil-paper dielectric, calculating the degree of - Automatic generation of the measured values on
humidity contained in the paper and evaluating the each test cycle graphic representation.
overall condition of the oilpaper.
- Results values are automatically corrected to a
A P P L I C AT I O N S reference temperature enabling standard results.
- The ETP-2 equipment measures the following: - Numerical and graphic presentation gives the
• Recovery Voltage of the insulation. results of the following parameters:
• Insulation Resistance. • Recovery Voltage.
• Polarization Index. • Raising time of the capacity.
To measure these parameters, the unit applies • Insulation Resistance.
different levels of DC test voltage through an • Time constant.
internal programmable voltage supply. The • Polarization Index.
measured values are acquired automatically in - The control program allows selecting the following
the specified time. The equipment evaluates the possibilities to perform the insulation tests:
actual general status of the insulation, and detects • HV + LV against ground
possible aging problems in the quality of the • HV against LV + ground
paper/oil insulation.
• HV against LV + Tertiary + ground, etc
- The ETP-2 can detect the following: - Dimensions:
• Solid dielectric degradation. 400 x 450 x135 mm. /10 kg.
• Liquid dielectric degradation. 16 x 19 x 5 in. /22 lb.
• Contaminated insulation.
www.smcint.com 33
ETP-3
T H R E E - P H A S E W I N D I N G R E S I S TA N C E M E T E R
DESCRIPTION C H A RACT E R I S T I C S
The ETP-3 is designed to measure very low - Performs the measurement of each phase,
resistance values on transformer windings or on any sequentially, without any change in the connection
load with a strong inductive component. The unit to the transformer, for each tap changer position.
applies the necessary DC current to magnetize the - Software guided.
winding and stabilize the current, in order to provide - Uses a four wire measuring method.
an accurate, repeatable measurement. - Automatic magnetization and de-magnetization of
the iron core.
A P P L I C AT I O N S
- Auto range from 1 mΩ to 1 KΩ.
The ETP-3 equipment measures the following for
- The test current range from 5 mA to 20 A is
any type of transformer or autotransformer:
automatically selected.
- Winding resistance value in single or three phases.
- Automatic calculation of the resistance per phase.
- Automatic correction of e resistance per phase to a
- Immunity to variation in the values of the
predetermined reference temperature
measurement circuit components, temperature
- Automatic calculation of the compound winding
changes, and changes in the test current.
resistance, for different configurations Delta, Star,
- Dimensions:
etc.
400 x 450 x135 mm. /12 kg.
- The ETP-3 can detect the following:
16 x 19 x 5 in. /27 lb.
• Loose connections.
• Tap changer malfunction.
• Shorted turns.
• Hot spots on the windings.
ETP-4
T H R E E - P H A S E S H O R T C I R C U I T I M P E D A N C E A N D S H O R T C I R C U I T V O LTA G E M E T E R
34 www.smcint.com
ETP System
T E S T S Y S T E M F O R P R E D I CT I V E M A I N T E N A N C E I N POW E R T RA N S F O R M E R S
DESCRIPTION A P P L I C AT I O N S
The ETP System is the combination of the equipment See ETP-1, 2, 3 and 4 previously mentioned.
ETP-1, ETP-2, ETP-3, and ETP-4, along with the
measurement, diagnostic and trend software, C H A RACT E R I S T I C S
See ETP-1, 2, 3 and 4 previously mentioned.
is a powerful tool for transformer maintenance
and prediction based on the critical state of the OPTIONS
transformer.
The software ETP DiagHelp integrates the results
of all the measurements obtained and applies in
the knowledge base, which visually and directly
indicate the critical and important information of
the transformer which may require attention in
the immediate or short term future. The software Optional Multi-socket power surge protection
ETP Trends is a historical register of the previous
tests made and offers a visual evolution of all the
factors analyzed, allowing a practical planning and
maintenance integration avoiding costly downtimes or
unnecessary substitutions.
The ETP is designed for easy use and accuracy, a
good inversion for predictive maintenance in power
transformers.
DESCRIPTION C H A RACT E R I S T I C S
The EDA system is ideal for the evaluation and - Initial reception and quality control of rotary machines
diagnosis of the insulation condition in electrical (generators, alternators, LV and MV motors).
rotary machines such as motors, generators, alternators, - Forming a part of a maintenance program on rotary
etc. Its main function is to analyze the condition of machines, where a non-programmed failure would
the stator winding insulation, using DC voltage levels represent a high costs, risks and installation outage, and
without risk to the element under test. The system of course, to verify failures.
obtains various parameters to evaluate the state of - To create a historial of the motors tested as the EDA
each of the components that make up the insulation in system generates a report. In this report all technical
a rotary machine. data of previous tests are presented in a structured
manner to easy follow the history of the element tested.
A P P L I C AT I O N S
- To evaluate the parameters tested, anticipating failures
- The following information is obtained from the EDA
and to diagnose the type of problem, thus planning in
system:
advance, the necessary maintenance steps required.
• Insulation resistance (corrected to 20º and 40ºC).
• Polarization index. - Dimensions:
• Absorption ratio. 400 x 450 x135 mm. / 9 kg.
• Leakage current. 16 x 19 x 5 in. / 20 lb.
• Standardized leakage intensity (voltage and capacitance).
• Leakage current ratio at each test voltage.
• Re-absorption current.
• Re-absorption current standardized for insulation
thickness.
• Time constant.
www.smcint.com 35
MCB test
equipment
C U R R E N T R E G U LAT I O N E Q U I P M E N T F O R LA B O R AT O RY U S E
The testing of MCB’s enables the detection of the deviations in the characteristics and the quality
control of these devices for the companies which manufactures or sells them. Random sample testing
is required for MCB manufactures and is normally carried out by Utilities when purchasing large
quantities. Testing those already installed in Industry is also required.
With this situation and the experience of SMC in AC current equipment, along with the demands
of the market in MCB testing, the design of this range of products, required by users in this type
of devices, is a product which is flexible to test various MCB’s, with different nominal values and
different tests at the same time. The stabilized current generator along with software control
gives reliable results. The system not only is capable of meeting international standards, but also
to those standards required in each country.
36 www.smcint.com
EMU RANGE
C U R R E N T P O W E R S U P P LY I N A . C .
E M U - 25 C H A RACT E R I S T I C S
E M U - 100 - Regulation:
E M U - 300 EMU-25: 0 - 25 A c.a.
DESCRIPTION EMU-100: 0 - 100 A c.a.
The EMU equipment are current power supplies EMU-300: 0 - 300 A c.a.
which are computer controlled. The principal - Nominal power: 300 VA.
function of these units is for laboratory testing which - Can be connected in parallel.
requires current injection of either short or long - Input for external phase and/or frequency
duration. The EMU units can be connected in parallel reference.
to achieve higher currents. - Computer controlled
- Overload, overheating alarm LED’s.
A P P L I C AT I O N S - Rack mounting 19 inches (482 mm).
- Testing of small circuit breakers. - Accuracy: ±1%.
- Calibration of shunts and measurement - Distortion: <1%.
instruments. - Dimensions:
- Testing of thermic relays which require a long 482 x 175 x 370 mm. /30 kg.
duration. 19 x 7 x 14 in. /75 lb.
- Overheating test.
SMC-12
A U T O M AT I C T E S T S Y S T E M F O R M I N I AT U R E C I R C U I T B R E A K E R S - M C B ’ S
DESCRIPTION C H A RACT E R I S T I C S
The SMC-12 system is designed to meet the needs - Up to 10 simultaneous and independent test
established by the International Standards for the positions.
routine and quality control tests of Miniature Circuits - Pre-selected current up to 100 A in each test
Breakers (MCB) with regards to their Thermal and position.
Magnetic response. - Fully automatic operation.
- Records, stores, and prints all test results.
A P P L I C AT I O N S
- Various tests can be performed at the same time.
- Designed to test thermal and magnetic
- Different current values and brands of MCB’s can be
(Instantaneous) response of miniature circuit
tested at the same time.
breakers (MCB’s).
- Can be connected in parallel to attain higher
- Meets the IEC 60898 - 2 requirements for testing
currents.
MCB’s.
- Low current output distortion (<1%).
- Programmable testing unit, computer controlled.
Time measurement: Resolution 0.1 s.
www.smcint.com 37
SMC offers customer support on-line
EUROPE OFFICE
E U RO S M C S. A.
P O L Í G O N O I N D U S T R I A L P - 29
C A L L E B U R I L , 69
28400 C O L LA D O V I L LA L B A
M A D R I D, S PA I N
T E L : +34 91 8498980
F A X : +34 91 8512553
[email protected]
USA OFFICE
N O RA M S M C I N C.
5840 S O U T H M E M O R I A L D R I V E - S U I T E 208
T U L S A - O K 74145 - U S A
T E L : +1 918 622 5725
F A X : +1 918 664 2073
[email protected]
ASIAN OFFICE
E U RO S M C S. A.
U N I T A , 15/ F , C H A R M H I L L C E N T R E ,
50 H I L LW O O D R D, T S I M S H A T S U I , K O W LO O N ,
H O N G KO N G S A R.
T E L : +852 3590 2499
F A X : +852 8343 0198
M O B : +852 9151 6899
[email protected]
www.smc i n t . c o m
NOTE: Due to the continuous research and development, the information contained in this catalog may be changed without notice. SMCCEN-version 6