Department of Electrical Engineering Assignment No. 1: Bahria University, Islamabad Campus

The document provides instructions for an assignment on power electronics. Students are asked to model a distorted current signal by adding harmonics to a 50Hz fundamental signal. They must create a Simulink model representing the fundamental and harmonic signals, use FFT analysis to analyze the distorted signal, and mitigate harmonics by generating anti-harmonics.

Uploaded by

Solar Ongrid
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
30 views1 page

Department of Electrical Engineering Assignment No. 1: Bahria University, Islamabad Campus

The document provides instructions for an assignment on power electronics. Students are asked to model a distorted current signal by adding harmonics to a 50Hz fundamental signal. They must create a Simulink model representing the fundamental and harmonic signals, use FFT analysis to analyze the distorted signal, and mitigate harmonics by generating anti-harmonics.

Uploaded by

Solar Ongrid
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 1

Bahria University, Islamabad Campus

Department of Electrical Engineering


Assignment No. 1
Class/Section: MS EE-3A
(Spring 2021 Semester)

Course: Power Electronics Date: 12.04.2021


Course Code: EEP-712 Time:
Faculty’s Name: Engr. Syed Umaid Ali Max Marks: 10
Due Date: 19.04.2021 Total Pages:

Student’s Name: Enroll No:


(USE CAPITAL LETTERS)

Q1.
In a rectifier circuit either single-phase or three-phase, the current drawn from the utility mains
is distorted due to the presence of L and C in the topology. This current distortion is normally
referred as harmonic distortion. To analyze the mitigation of distortion, anti-harmonics are
injected into the mains. In this assignment your task is to artificially layout a distorted signal as
a replica of the main’s current. You can do it by adding 3rd, 5th, 7th, 9th, 11th, 13th, 15th, 17th and
19th harmonic into a 50Hz fundamental signal of amplitude of 100A.

The deliverables include Simulink Modeling concerning


• Complete signal representation of fundamental and harmonics including the distorted
one. (5)
• Use of Simulink’s FFT Analysis Tool to access the distorted signal in terms of presence
of harmonics with amplitudes. Complete representation is desired. (Hint:
https://www.youtube.com/watch?v=3GF-r9d96ss). (2.5)
• Mitigation of harmonics by generating anti-harmonics. Complete representation is
desired. (2.5)

Page 1 of 1