Product Data Sheet: Closed Toroid For Residual Current Protection PA - Ø 50 MM

This document provides information on a closed toroid current sensor called the PA50 that is used for residual current protection. It has a rated operational current of 85A, works on AC and DC networks from 45-440Hz, and can withstand short circuit currents up to 100kA. The sensor clips onto a Vigirex relay, has an IP20/IP30 rating, and operates in temperatures from -35°C to 70°C. It complies with various industry standards for safety and environmental testing.

Uploaded by

Marek Piškula
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
124 views2 pages

Product Data Sheet: Closed Toroid For Residual Current Protection PA - Ø 50 MM

This document provides information on a closed toroid current sensor called the PA50 that is used for residual current protection. It has a rated operational current of 85A, works on AC and DC networks from 45-440Hz, and can withstand short circuit currents up to 100kA. The sensor clips onto a Vigirex relay, has an IP20/IP30 rating, and operates in temperatures from -35°C to 70°C. It complies with various industry standards for safety and environmental testing.

Uploaded by

Marek Piškula
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 2

Product data sheet 50438

Characteristics Closed toroid for residual current protection PA -


Ø 50 mm

Main

Disclaimer: This documentation is not intended as a substitute for and is not to be used for determining suitability or reliability of these products for specific user applications
Range Vigirex
Device short name PA50
Product or component type Earth leakage current sensor
Device application Equipment monitoring and control
Range compatibility Vigirex RH plug-in relay
[Ie] rated operational current 85 A

Complementary
Current sensor type A type closed toroid
Network type AC
DC
Network frequency 45...440 Hz
[Ui] rated insulation voltage 1000 V
Transformer ratio 1/1000
[Icw] rated short-time withstand current 100 kA / 0.5 s
Residual short-circuit withstand 85 kA / 0.5 s conforming to IEC 60947-2
current
Overvoltage category IV
[Uimp] rated impulse withstand voltage 12 kV
Mounting mode Clip-on Vigirex relay
Fixed plain backplate
Fixed profiled sheet metal
Fixed slotted backplate
Clip-on DIN rail
Calorific value 1.42 MJ
Connections - terminals Screw connection : >= 0.22 mm²
Diameter 50 mm (inner)
Cable outer diameter 25 mm : 50 mm² (maximum)
Product weight 0.2 kg
Height 108 mm
Width 88 mm
Depth 29 mm

Jan 16, 2019


1
Environment
IP degree of protection Connectors : IP20
IP30
Environmental characteristic Exposure to damp heat not in service conforming to IEC 60068-2-30 : 28 cycles 25...55 °C, RH 95 %
Salt mist conforming to IEC 60068-2-52 : Kb/2
Exposure to damp heat in service conforming to IEC 60068-2-56 : 48 hours : category C2
Pollution degree Level 3 conforming to IEC 60664-1
Ambient air temperature for operation -35...70 °C
Ambient air temperature for storage -55...85 °C

Offer Sustainability
RoHS (date code: YYWW) Compliant  - since  0901  -  Schneider Electric declaration of conformity
Schneider Electric declaration of conformity
Product environmental profile Available
Product Environmental Profile
Product end of life instructions Available
End of Life Information

Contractual warranty
Warranty period 18 months