01-02 Working Principles of The GOMU Board

The document describes the working principles of the GOMU board in the HUAWEI BSC6000 Base Station Controller. It discusses the Ethernet adapter configuration of the GOMU board in single-server and dual-server modes. It also explains the networking principles, including how the internal Ethernet adapters connect to the GSCU boards and how the external adapters connect to the O&M system for communication between the BSC and O&M. Data synchronization and switchover processes are covered for dual-server GOMU boards.

Uploaded by

Awa Stelk
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
58 views6 pages

01-02 Working Principles of The GOMU Board

The document describes the working principles of the GOMU board in the HUAWEI BSC6000 Base Station Controller. It discusses the Ethernet adapter configuration of the GOMU board in single-server and dual-server modes. It also explains the networking principles, including how the internal Ethernet adapters connect to the GSCU boards and how the external adapters connect to the O&M system for communication between the BSC and O&M. Data synchronization and switchover processes are covered for dual-server GOMU boards.

Uploaded by

Awa Stelk
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 6

HUAWEI BSC6000 Base Station Controller

BSC GOMU Administration Guide 2 Working Principles of the GOMU Board

2 Working Principles of the GOMU Board

About This Chapter

This topic describes working principles of the GOMU board. One or two GOMU boards are
configured on the BSC to communicate between the BSC and the O&M system.

2.1 Ethernet Adapter Configuration of the GOMU Board


This topic describes the Ethernet adapter configuration of the GOMU board in the process of
installing the GOMU operating system.
2.2 Networking Principles of the GOMU Board
This topic describes networking principles of the GOMU board. The internal Ethernet adapter
of the GOMU board is connected to the GSCU board in the GMPS subrack. The external Ethernet
adapter of the GOMU board is connected to the O&M system to communicate between the BSC
and the O&M system.
2.3 Data Synchronization Between Active and Standby GOMU Boards
This topic describes the data synchronization between active and standby GOMU boards. When
the GOMU board is working in dual-server mode, the standby GOMU board automatically
synchronizes the data of the active GOMU board.
2.4 Heartbeat Test on Active/Standby GOMU Boards
This topic describes the heartbeat test on active/standby GOMU boards in dual-server mode.
The active/standby GOMU boards perform the heartbeat test function to ensure the normal state
of active/standby GOMU boards.
2.5 Switchover Between Active/Standby GOMU Boards
This topic describes the switchover between active/standby GOMU boards when the GOMU
board is working in dual-server mode. There are two switchover ways: manual switchover and
automatic switchover.

Issue 01 (2007-09-21) Huawei Technologies Proprietary 2-1


HUAWEI BSC6000 Base Station Controller
2 Working Principles of the GOMU Board BSC GOMU Administration Guide

2.1 Ethernet Adapter Configuration of the GOMU Board


This topic describes the Ethernet adapter configuration of the GOMU board in the process of
installing the GOMU operating system.

Ethernet Adapter Configuration in Single-Server Mode


One BSC is configured with one GOMU board. There are six Ethernet adapters in total on the
GOMU board. The ETH0, ETH1, and ETH2 are configured on the three Ethernet adapter ports
on the GOMU panel. The ETH3-UPDATE, ETH4-SCU7, and ETH5-SCU6 are configured on
the three Ethernet adapter ports on the GOMU backplane. After the Ethernet adapter teaming,
the Ethernet adapters on the GOMU board are as follows:
l The ETH0 and ETH1 are teamed as the external Ethernet adapter team bond1 of active/
standby switchover. The bond1 communicates between the GOMU board and O&M system
(LMT and M2000).
NOTE
After installing the OMU software, run the omuctrl cfg command to configure the IP address of the
external Ethernet adapter team.
l The IP address and subnet mask of the ETH2 are \\192.168.1.1 and \\255.255.255.0
respectively.
l The ETH4-SCU7 and ETH5-SCU6 are teamed as the internal Ethernet adapter team bond0
of active/standby switchover. The GOMU LOCAL and GOMU CORE of the GOMU board
applies the bond0.

Ethernet Adapter Configuration in Dual-Server Mode


One BSC is configured with two GOMU boards. There are six Ethernet adapters on both the
active and standby GOMU boards. The ETH0, ETH1, and ETH2 are configured on the three
Ethernet adapter ports on the GOMU panel. The ETH3-UPDATE, ETH4-SCU7, and ETH5-
SCU6 are configured on the three Ethernet adapter ports on the GOMU backplane. After the
Ethernet adapter teaming, the Ethernet adapters on the GOMU board are as follows:
The IP address configurations of the active GOMU board are as follows:
l The ETH0 and ETH1 are teamed as the external Ethernet adapter team bond1 of active/
standby switchover. The bond1 communicates between the GOMU board and O&M system
(LMT and M2000).
NOTE
After installing the OMU software, run the omuctrl cfg command to configure the IP address of the
external Ethernet adapter team.
l The IP address and subnet mask of the ETH2 are \\192.168.1.1 and \\255.255.255.0
respectively.
l The ETH3-UPDATE is used for the data synchronization between the active and standby
GOMU boards and for the update of the active and standby OMU software.
l The ETH4-SCU7 and ETH5-SCU6 are teamed as the internal Ethernet adapter team bond0
of active/standby switchover. The GOMU LOCAL and GOMU CORE of the GOMU board
applies the bond0.
The IP address configuration of the standby GOMU board is similar to that of the active GOMU
board.

2-2 Huawei Technologies Proprietary Issue 01 (2007-09-21)


HUAWEI BSC6000 Base Station Controller
BSC GOMU Administration Guide 2 Working Principles of the GOMU Board

2.2 Networking Principles of the GOMU Board


This topic describes networking principles of the GOMU board. The internal Ethernet adapter
of the GOMU board is connected to the GSCU board in the GMPS subrack. The external Ethernet
adapter of the GOMU board is connected to the O&M system to communicate between the BSC
and the O&M system.

Networking Principles in Single-Server Mode


Figure 2-1 shows the onsite networking diagram of the GOMU board in single-server mode.

Figure 2-1 Networking diagram in single-server mode

Slot 6 Slot 7
GSCU GSCU

Internal
network

ETH5-SCU6 ETH4-SCU7 ETH3-UPDATE

ETH2 ETH1 ETH0

GOMU

Hub

External
network

Other network equipment (such as hub, LAN switch,and router)

LMT M2000 ……

Backplane transmission
Ethernet cable transmission

The two internal Ethernet adapters ETH4-SCU7 and ETH5-SCU6 on the GOMU board
backplane are connected to GSCUs in slot 7 and slot 6 respectively in the GMPS subrack.
Through the network equipment, such as the HUB, Lan swith , and router, the two external
Ethernet adapters ETH0 and ETH1 of the GOMU board are connected to the O&M system to
communicate between the BSC and the O&M system.

Issue 01 (2007-09-21) Huawei Technologies Proprietary 2-3


HUAWEI BSC6000 Base Station Controller
2 Working Principles of the GOMU Board BSC GOMU Administration Guide

Networking Principles in Dual-Server Mode


Figure 2-2 shows the onsite networking diagram of the GOMU board in dual-server mode.

Figure 2-2 Networking diagram in dual-server mode

Slot 7 Slot 6
GSCU GSCU
Internal
network

ETH4-SCU7 ETH5-SCU6 ETH3-UPDATE ETH3-UPDATE 内网


ETH4-SCU7 ETH5-SCU6

ETH2 ETH1 ETH0 ETH0 ETH1 ETH2

Active GOMU Standby GOMU

Hub

External
network

Other network equipment (such as hub, LAN switch,and router)

LMT M2000 ……

Backplane transmission
Ethernet cable transmission

The two internal Ethernet adapters ETH4-SCU7 and ETH5-SCU6 on the GOMU board
backplane are connected to GSCUs in slot 7 and slot 6 respectively in the GMPS subrack.
Through the network equipment, such as the HUB, Lan swith , and router, the two external
Ethernet adapters ETH0 and ETH1 of the GOMU board are connected to the O&M system to
communicate between the BSC and the O&M system.
The working principles of the standby GOMU board is similar to that of the active GOMU board.
The ETH3-UPDATEs of the active and standby GOMU boards are connected to each other
through the backplane. The ETH3-UPDATE performs the data synchronization between active
and standby GOMU boards and the update of the OMU software.

2-4 Huawei Technologies Proprietary Issue 01 (2007-09-21)


HUAWEI BSC6000 Base Station Controller
BSC GOMU Administration Guide 2 Working Principles of the GOMU Board

2.3 Data Synchronization Between Active and Standby


GOMU Boards
This topic describes the data synchronization between active and standby GOMU boards. When
the GOMU board is working in dual-server mode, the standby GOMU board automatically
synchronizes the data of the active GOMU board.
The data of the GOMU board is dynamic. It is changing when the BSC is running. Therefore,
when the data of the active GOMU board changes, the changed data needs to be delivered to the
standby GOMU board to ensure that no data is lost after the active and standby GOMU boards
are switched over. Thus the standby GOMU board can replace the active GOMU board.
The data synchronization is the synchronization of the dynamic data files. These data files consist
of the data configuration file, performance and measurement file, procedure file, and License
file.

2.4 Heartbeat Test on Active/Standby GOMU Boards


This topic describes the heartbeat test on active/standby GOMU boards in dual-server mode.
The active/standby GOMU boards perform the heartbeat test function to ensure the normal state
of active/standby GOMU boards.
The heartbeat indicates the information signal delivered between the active and standby GOMU
boards. It is the no-response message. In dual-server mode, the active and standby GOMU boards
send the heartbeat message to each other to show the active/standby GOMU boards and the
network connection are normal.
There are two heartbeat channels between active and standby GOMU boards: internal network
channel and backup channel.
l If the active GOMU board can receive the heartbeat message from the standby GOMU
board regularly through the two heartbeat channels. it shows that the active and standby
GOMU boards communicate normally, and the GOMU boards communicate with the
external network normally.
l If the active/standby GOMU boards do not receive the heartbeat message from each other
through any heartbeat channel in five seconds, it indicates that the heartbeat channel is
disconnected. The active GOMU board reports the alarm.
l If the two heartbeat channels are disconnected for over five seconds, and the internal and
external network of the standby GOMU board communicate normally, the standby GOMU
board automatically switches over to the the active GOMU board.

2.5 Switchover Between Active/Standby GOMU Boards


This topic describes the switchover between active/standby GOMU boards when the GOMU
board is working in dual-server mode. There are two switchover ways: manual switchover and
automatic switchover.

Issue 01 (2007-09-21) Huawei Technologies Proprietary 2-5


HUAWEI BSC6000 Base Station Controller
2 Working Principles of the GOMU Board BSC GOMU Administration Guide

NOTE

l The switchover between the active and standby GOMU boards takes about two to three minutes. The
data synchronization after the switchover takes about 30 to 50 minutes.
l The communication between the O&M system and BSC is disrupted about two to three minutes in the
process of the active/standby GOMU board switchover.

Manual Swtichover
When the GOMU board is working in dual-server mode, and the data synchronization between
the active/standby GOMU boards is normal, the GOMU board can be forced to be switched over
manually according to the actual situation. After the manual switchover, the standby GOMU
board is switched over to the active GOMU board, and the active GOMU board is switched over
to the standby GOMU board.

Automatic Switchover
When the GOMU board is working normally in dual-server mode, only the active GOMU board
is running. The standby GOMU board is monitoring the active GOMU board. When the active
GOMU board is faulty, and the time duration is over one minute, the standby GOMU board
automatically switches over to the active GOMU board. When the active GOMU fault is cleared,
the standby GOMU board restored to its original state. If the active GOMU board fault is cleared
within one minute, the switchover does not occur.

2-6 Huawei Technologies Proprietary Issue 01 (2007-09-21)