Ident Configuration Guide 2020-08

Download as pdf or txt
Download as pdf or txt
You are on page 1of 79

August 2020

SIMATIC Ident
Configuration Guide
Unrestricted © Siemens 2020. All rights reserved. siemens.com/ident
Content
Important notes:

Select and configure a SIMATIC RF Family ................................ …… 3


RF200 All selection possibilities of this
Family Matrix ................................................................................. 4
System Interfaces ......................................................................... 16 SIMATIC Ident Configuration Guide

RF300 can also be found in the TIA Selection Tool.


Family Matrix ................................................................................ 21 This tool is available at:
System Interfaces .......................................................................... 33 http://www.siemens.com/tst
RF600
Family Matrix ............................................................................... 36
Other functional highlights of the selection tool:
System Interfaces ......................................................................... 42
• Create order lists
RF1000 • Get price information by application to the mall
Family Matrix ............................................................................... 45 • Select other automation components
System Interfaces ......................................................................... 47 (control devices, IO-Systems,
industrial communication)
RF Handheld Reader ........................................................................ 50 • Network view of all components
RF Software DVD ............................................................................. 52 • Retrieve and compare technical data
• … and much more
Configure an Optical Identification System
MV400/ MV500
Lens configurator ......................................................................... 53
System Interfaces MV420 ............................................................. 57 All current wireless approvals can be found
System Interfaces MV440 ............................................................. 61 on the Internet at:
System Interfaces MV500 ............................................................. 66 http://www.siemens.com/rfid-approvals
MV300 System Interfaces ................................................................ 72
System interfaces for general purpose serial devices ............... 74
The newest version of this configuration guide
Bill of Materials Guide is published at:
RF18xC / CI................................................................................... 75 https://support.industry.siemens.com/cs/ww/en/view/67384964
RF 166C ....................................................................................... 77
Bulk Cable and Connectors ............................................................... 78

Corrections mailto: [email protected]


Edition: August 2020 SIMATIC Ident Configuration Guide
Each SIMATIC RF Family has characteristics that orients it to a particular range of applications:
■ The first step is to understand the application by asking the right questions. Out of this process, the best-suited SIMATIC RF family can be determined
■ A reader and tag combination within the specific family can be selected using the SIMATIC RF family matrix pages
■ Within the chosen family, a network interface to the control system can be selected using the system interfaces pages

Technology HF UHF Environment Heavy Heavy


RF200 RF300 RF600 What kind of RF200 RF300 RF600
environmental
What is the basic
extremes will the
RF technology?
tags be subjected
13.56 MHz 13.56 MHz 868/915 MHz 220°C 220°C 230°C
to? IP68 IP68 IP68
Passive Passive Passive

Read Distance Shorter Longer Reader Dimensions Smallest Largest


How far away can RF300 RF200 RF600 RF200 RF300 RF600
the tag be from the How much space will
reader antenna there be for mounting
system and still be the reader/ antenna?
seen? 210 mm 650 mm 8 meters M8 x 38 M12 x 40 75 x 75 x 20

Tag Memory Less More Multitag Mode Less More


RF600 RF200 RF300 RF200 RF300 RF600
How many bytes Will there be more
are required to be than one tag in the
stored on the tag? RF field at a time?
384 bytes 8 kbytes 64 kbytes 1 1 100+

Metal Effects Direct Mount Spacer Mount Tag Speed Slower Faster
RF300 RF600 RF200 RF200 RF300 RF600
Do tags and How fast will the
reader need to be tag be traveling
mounted on or through the RF
around metal? Direct with Direct with Spacer field?
26 kbits/sec 100 kbits/sec 300 kbits/sec
reduction reduction Mount

Tag Dimensions Smallest Largest Air Interface Protocol Siemens Standard


RF200 RF300 RF600 RF300 RF200 RF600
Are there any
What is the
requirements
smallest tag size
regarding the air
available?
Ø4x5 Ø4x5 Ø 21 x 20 interface protocol? Siemens/ ISO 18000
mm mm mm ISO15693/14443 ISO 15693 -62/ -63

Edition: August 2020 SIMATIC Ident Configuration Guide 3


D165 D261 D100 D200 D400 D160 D460 D560
RF200 Antennas 6GT2 600-1AB00-0AX0 6GT2 600-1AA01-0AX0 6GT2 600-0AD10 6GT2 600-1AD00 -0AX0 6GT2 600-4AD00 6GT2 600-0AB10 6GT2 600-4AB00 6GT2 600-5AB00

Family Matrix 112 byte EEPROM 256 byte EEPROM 112 byte EEPROM 256 byte EEPROM 2 kbyte FRAM 112 byte EEPROM 2 kbyte FRAM 8 kbyte FRAM

13.56 MHz
Passive Tags
Operational temperature range -25°C to 85°C -25°C to 85°C -25°C to 80°C -20°C to 60°C -20°C to 60°C -40°C to 175°C -40°C to 100°C -40°C to 90°C
Dimensions (L x W x D) mm 86 x 54 x 0.3 55 x 55 x 0.3 85,6 x 54 x 0.9 85.6 x 54 x 0.8 85.6 x 54 x 0.8 Ø 16 x 3 Ø 16 x 3 Ø 16 x 3
Ingress Protection (IP) rating IP65 IP65 IP68 IP67 IP67 IP68/IPx9K IP67/IPx9K IP68/IPx9K
RF210R/ RF210M
6GT2 821-1AC10, RS422
Integrated 1-10/ 12 1-8/ 9 1-8/ 9
6GT2 821-1AC32 / -1BC32, IO-Link*
(0.04-0.39/ 0.47) (0.04-0.31/ 0.35) (0.04-0.31/ 0.35
6GT2 823-0AA00, Handheld (RS422)
M18 x 71
RF220R
6GT2 821-2AC10, RS422
Integrated 1-20/ 22 1-18/ 20 1-18/ 20
6GT2 821-2AC32 / -2BC32, IO-Link* (0.04-0.79/ 0.87) (0.04-0.71/ 0.79) (0.04-0.71/ 0.79
M30 x 71
RF240R
6GT2 821-4AC10, RS422
Integrated 2-80/ 94 2-60/ 70 2-84/ 95 2-69/ 78 2-80/ 90 1-33/ 37 1-30/ 34 1-30/ 34
6GT2 821-4AC40, RS232 (ASCII)
(0.08-3.15/ 3.70) (0.08-2.36/ 2.76) (0.08-3.31/ 3.74) (0.08-2.72/ 3.07) (0.08-3.15/ 3.54) (0.04-1.30/ 1.46) (0.04-1.18/ 1.34) (0.04-1.18/ 1.34)
6GT2821-4AC32 / -4BC32, IO-Link*
50 x 50 x 30
RF250R ANT 1
6GT2 821-5AC10, RS422 5-95/ 110 2-90/ 110 5-95/ 115 5-90/ 100 10-95/ 110 2-35/ 45 2-30/ 40 2-30/ 40
6GT2 821-5AC40, RS232 (ASCII) (0.20-3.74/ 4.33) (0.08-3.54/ 4.33) (0.20-3.74/ 4.53) (0.20-3.54/ 3.94) (0.39-3.74/ 4.33) (0.08-1,38/ 1.77) (0.08-1.18/ 1.57) (0.08-1.18/ 1.57)
6GT2821-5AC32 / -5BC32, IO-Link*
6GT2 398-1CB00, ANT 1 75 x 75 x 20
RF250R ANT 3
6GT2 821-5AC10, RS422 1-23/ 30 0-21/ 27 0-21/ 27
6GT2 821-5AC40, RS232 (ASCII)
(0.04-0.91/1.18) (0-0.83/ 1.06) (0-0.83/ 1.06)
6GT2821-5AC32 / -5BC32, IO-Link*
6GT2 398-1CD40-0AX0, ANT 3 28 x 50 x 10
RF250R ANT 3S
6GT2 821-5AC10, RS422
6GT2 821-5AC40, RS232 (ASCII)
6GT2821-5AC32 / -5BC32, IO-Link*
6GT2 398-1CD60-0AX0, ANT 3S 28 x 50 x 10
RF250R ANT 8
6GT2 821-5AC10, RS422
6GT2 821-5AC40, RS232 (ASCII)
6GT2821-5AC32 / -5BC32, IO-Link*
6GT2 398-1CF10, ANT 8 Ø8 x 40
RF250R ANT 12
6GT2 821-5AC10, RS422 0-12/ 17 1-10/ 14 1-10/ 14
6GT2 821-5AC40, RS232 (ASCII)
(0-0.47/ 0.67) (0.04-0.39/ 0.55) (0.04-0.39/ 0.55
6GT2821-5AC32 / -5BC32, IO-Link*
6GT2 398-1CC00, ANT 12** *** Ø12 x 40
Holder Holder Holder
(6GT2 390-0AA00) (6GT2 390-0AA00)
Spacer Spacer Spacer
(6GT2 390-0AA00) (6GT2 690-0AG00) (6GT2 690-0AG00) (6GT2 690-0AG00)
Accessories 20 mm spacer 20 mm spacer 20 mm spacer
(6GT2 190-0AA00) (6GT2 190-0AA00) (6GT2 190-0AA00)
Angle pattern Angle pattern Angle pattern
Fixing pocket Fixing pocket body body body
Fixing pocket (6GT2690-0AN00) (6GT2690-0AN00) (6GT2690-0AN00)
(6GT2 190-0AB00) (6GT2 190-0AB00) (6GT2 190-0AB00)

Operating Distance Range (mm) / Maximum Distance for Stationary Tag (mm)
Operating Distance Range (inch) / Maximum Distance for Stationary Tag (inch)

Edition: August 2020 SIMATIC Ident Configuration Guide 4


D165 D261 D100 D200 D400 D160 D460 D560
RF200 Antennas 6GT2 600-1AB00-0AX0 6GT2 600-1AA01-0AX0 6GT2 600-0AD10 6GT2 600-1AD00 -0AX0 6GT2 600-4AD00 6GT2 600-0AB10 6GT2 600-4AB00 6GT2 600-5AB00

Family Matrix 112 byte EEPROM 256 byte EEPROM 112 byte EEPROM 256 byte EEPROM 2 kbyte FRAM 112 byte EEPROM 2 kbyte FRAM 8 kbyte FRAM

13.56 MHz
Passive Tags
Operational temperature range -25°C to 85°C -25°C to 85°C -25°C to 80°C -20°C to 60°C -20°C to 60°C -40°C to 175°C -40°C to 100°C -40°C to 90°C
Dimensions (L x W x D) mm 86 x 54 x 0.3 55 x 55 x 0.3 85,6 x 54 x 0.9 85.6 x 54 x 0.8 85.6 x 54 x 0.8 Ø 16 x 3 Ø 16 x 3 Ø 16 x 3
Ingress Protection (IP) rating IP65 IP65 IP68 IP67 IP67 IP68/IPx9K IP67/IPx9K IP68/IPx9K
RF250R ANT 18
6GT2 821-5AC10, RS422 1-18/ 26 1-17/ 21 1-17/ 21
6GT2 821-5AC40, RS232 (ASCII) (0.04-0.71/ 1.02) (0.04-0.67/ 0.83) (0.04-0.67/ 0.83)
6GT2821-5AC32 / -5BC32, IO-Link*
6GT2 398-1CA00, ANT 18** *** Ø18 x 55
RF250R ANT 30
6GT2 821-5AC10, RS422 1-23/ 30 1-21/ 27 1-21/ 27
6GT2 821-5AC40, RS232 (ASCII) (0.04-0.91/ 1.18) (0.04-0.83/ 1.06) (0.04-0.83/ 1.06)
6GT2821-5AC32 / -5BC32, IO-Link*
6GT2 398-1CD00, ANT 30** Ø30 x 58
RF260R
6GT2 821-6AC10, RS422 Integrated 2-120/ 135 2-75/ 90 2-110/ 130 2-100/ 120 2-90/ 120 2-40/ 45 2-40/45 2-40/45
(0.08-4.72/ 5.31) (0.08-2.95/ 3.54) (0.08-4.33/ 5.12) (1.18-3.94/ 4.72) (0.08-3.54/ 4.72) (0.08-1.57/ 1.77) (0.08-1.57/ 1.77) (0.08-1.57/ 1.77)
6GT2 821-6AC40, RS232 (ASCII)
6GT2 821-6AC32 / -6BC32, IO-Link*

RF280R Integrated 10 -160/ 190 20-110/ 150 10-160/ 200 20-140/ 185 5-150/ 180 2-55/ 70 2-55/ 70 2-55/ 70
6GT2 821-8AC10, RS422
(0.39-6.3/ 7.48) (0.79-4.33/ 5.91) (0.39-6.3/ 7.87) (0.79-5.51/ 7.28) (0.20-5.91/ 7.09) (0.08-2.17/ 2.76) (0.08-2.17/ 2.76) (0.08-2.17/ 2.76)
6GT2 821-8AC40, RS232 (ASCII)

Holder Holder Holder Spacer Spacer Spacer


(6GT2 390-0AA00) (6GT2 390-0AA00) (6GT2 390-0AA00) (6GT2 690-0AG00) (6GT2 690-0AG00) (6GT2 690-0AG00)
Accessories 20 mm spacer 20 mm spacer 20 mm spacer
(6GT2 190-0AA00) (6GT2 190-0AA00) (6GT2 190-0AA00)
Angle pattern Angle pattern Angle pattern
Fixing pocket Fixing pocket Fixing pocket body body body
(6GT2 190-0AB00) (6GT2 190-0AB00) (6GT2 190-0AB00) (6GT2690-0AN00) (6GT2690-0AN00) (6GT2690-0AN00)

* not with Tags D5xx


** antennas also available in stainless steel: ANT12 (6GT2398-1DC10), ANT18 (6GT2398-1DA10), ANT30 (6GT2398-1DD10)
*** antennas also available with 0.6 m antenna cable; ANT12 (6GT2398-1CC10), ANT18 (6GT2398-1CA10)

Operating Distance Range (mm) / Maximum Distance for Stationary Tag (mm)
Operating Distance Range (inch) / Maximum Distance for Stationary Tag (inch)

Edition: August 2020 SIMATIC Ident Configuration Guide 5


D165 D261 D100 D200 D400 D160 D460 D560
RF200 Antennas 6GT2 600-1AB00-0AX0 6GT2 600-1AA01-0AX0 6GT2 600-0AD10 6GT2 600-1AD00 -0AX0 6GT2 600-4AD00 6GT2 600-0AB10 6GT2 600-4AB00 6GT2 600-5AB00

Family Matrix 112 byte EEPROM 256 byte EEPROM 112 byte EEPROM 256 byte EEPROM 2 kbyte FRAM 112 byte EEPROM 2 kbyte FRAM 8 kbyte FRAM

13.56 MHz
Passive Tags
Operational temperature range -25°C to 85°C -25°C to 85°C -25°C to 80°C -20°C to 60°C -20°C to 60°C -40°C to 175°C -40°C to 100°C -40°C to 90°C
Dimensions (L x W x D) mm 86 x 54 x 0.3 55 x 55 x 0.3 85,6 x 54 x 0.9 85.6 x 54 x 0.8 85.6 x 54 x 0.8 Ø 16 x 3 Ø 16 x 3 Ø 16 x 3
Ingress Protection (IP) rating IP65 IP65 IP68 IP67 IP67 IP68/IPx9K IP67/IPx9K IP68/IPx9K
RF285R ANT D1
6GT2821-7AC12, RS232 10-150/200 5-130/180 10-150/200 10-130/180 10-105/145 0-65/90 0-60/85 0-60/85
(0.39-5.91/ 7.87) (0.20-5.12/ 7.09) (0.39-5.91/ 7.87) (0.39-5.12/ 7.09) (0.39-4.13/ 5.71) (0-2.56/ 3.54) (0-2.36/ 3.35) (0-2.36/ 3.35)
6GT2 698-5AC00
75 x 75 x 20
ANT D5
0-300/380 0-300/380 0-350/450 0-350/450 0-240/320 0-110/140 0-100/120 0-110/140
(0-11.81/ 14.96) (0-11.81/ 14.96) (0-13.78/ 17.72) (0-13.78/ 17.72) (0-9.45/ 12.6) (0-4.33/ 5.51) (0-3.94/ 4.72) (0-4.33/ 5.51)
6GT2 698-5AA10
380 x 380 x 110
ANT D6

Accessory:
0-350/450 0-300/400 0-450/550 0-350/450 0-320/400
Set for top rail mounting (0-13.78/ 17.72) (0-11.81/ 15.75) (0-17.72/ 21.65) (0-13.78/ 17.72) (0-12.6/ 15.75)
6GT2 698-5AB00
6GK5798-8ML00-0AB3 580 x 480 x 110
ANT D1
RF290R
6GT2 821-0AC12, RS232, RS422 10-180/ 250 5-130/ 180 10-180/ 250 10-170/240 10-170/240 0-65/90 0-60/85 0-60/85
6GT2 698-5AC00 (0.39-7.09/ 9.84) (0.39-5.12/ 7.09) (0.39-7.09/ 9.84) (0.39-6.69/ 9.45) (0.39-6.69/ 9.45) (0-2.56/ 3.54) (0-2.36/ 3.35) (0-2.36/ 3.35)
75 x 75 x 20
ANT D5
0-350/ 450 0-300/ 400 0-400/ 500 0-400/ 500 0-300/ 375 0-130/ 180 0-120/ 160 0-120/ 160
6GT2 698-5AA10 (0-13.78/ 17.72) (0-11.81 / 15.75) (0-15.75/ 19.69) (0-15.75/ 19.69) (0-11.81/ 14.76) (0-5.12/ 7.09) (0-4.72/ 6.30) (0-4.72/ 6.30)
380 x 380 x 110
ANT D6
0-400/ 500 0-350/ 450 0-550/ 650 0-500/ 600 0-500/ 650
6GT2 698-5AB00 (0-15.75/ 19.69) (0-13.78 / 17.72) (0-21.65/ 25.59) (0-19.69/ 23.62) (0-19.69/ 25.59)
580 x 480 x 110
ANT D10

Accessory: 0-350/ 450 0-350/ 450 0-500/ 600 0-450/ 550 0-400/ 500
Set for top rail mounting 6GT2 698-5AF00 (0-13.78/ 17.72) (0-13.78 / 17.72) (0-19.69/ 23.62) (0-17.72/ 21.65) (0-15.75/ 19.69)
6GK5798-8ML00-0AB3 1150 x 365 x 115

Holder Holder Holder Spacer Spacer Spacer


Covering hood (6GT2 390-0AA00) (6GT2 390-0AA00) (6GT2 390-0AA00) (6GT2 690-0AG00) (6GT2 690-0AG00) (6GT2 690-0AG00)
Accessories for ANT D6 20 mm spacer 20 mm spacer 20 mm spacer
(6GT2 190-0AA00) (6GT2 190-0AA00) (6GT2 190-0AA00)
Angle pattern Angle pattern Angle pattern
(6GT2 690-0AD00) body body body
Fixing pocket Fixing pocket Fixing pocket
(6GT2 190-0AB00) (6GT2 190-0AB00) (6GT2 190-0AB00) (6GT2690-0AN00) (6GT2690-0AN00) (6GT2690-0AN00)

Operating Distance Range (mm) / Maximum Distance for Stationary Tag (mm)
Operating Distance Range (inch) / Maximum Distance for Stationary Tag (inch)

Edition: August 2020 SIMATIC Ident Configuration Guide 6


D117 D127 D421 D521 D422 D522
RF200 Family Matrix Antennas 6GT2 600-0AG00 6GT2 600-0AF00 6GT2 600-4AE00 6GT2 600-5AE00 6GT2 600-4AF00 6GT2600-5AF00
112 byte 112 byte EEPROM 2 kbyte FRAM 8 kbyte FRAM 2 kbyte FRAM 6GT2600-5AF00-0AX0
EEPROM 8 kbyte FRAM
13.56 MHz
Passive Tags

Operational temperature range -40°C to 125°C -40°C to 125°C -40°C to 100°C -40°C to 100°C -40°C to 100°C -40°C to 100°C
Dimensions (L x W x D) mm Ø4 x 5.2 Ø 6 x 5.8 Ø10 x 4.5 Ø10 x 4.5 Ø20 x 6 Ø20 x 6 ; Ø18 x 5.2
Ingress Protection (IP) rating IP68 IPx9K IP68/ IPx9K IP67/ IPx9K IP67/ IPx9K IP68 IP68
RF210R/ RF210M
6GT2 821-1AC10, RS422
Integrated 0-2/ 2 0-3/ 4 0-3/ 4 1-9/ 10 1-8/ 9
6GT2 821-1AC32 / -1BC32, IO-Link* (0-0.08/ 0.08) (0.0-0.12/ 0.16) (0-0.12/ 0.16) (0.04-0.35/ 0.39) (0.04-0.31/ 0.35)
6GT2 823-0AA00, Handheld (RS422)
M18 x 71
RF220R
6GT2 821-2AC10, RS422
Integrated 1-12/ 14 1-10/ 12
6GT2 821-2AC32 / -2BC32, IO-Link*
(0.04-0.47/ 0.55) (0.04-0.39/ 0.47)
M30 x 71
RF240R
6GT2 821-4AC10, RS422
Integrated 1-12/ 15 1-10/ 12
6GT2 821-4AC40, RS232 (ASCII)
(0.04-0.47/ 0.59) (0.04-0.39/ 0.47)
6GT2821-4AC32 / -4BC32, IO-Link*
50 x 50 x 30
RF250R ANT 1
6GT2 821-5AC10, RS422
6GT2 821-5AC40, RS232 (ASCII)
6GT2821-5AC32 / -5BC32, IO-Link*
6GT2 398-1CB00, ANT 1 75 x 75 x 20
RF250R ANT 3
6GT2 821-5AC10, RS422 1-12/ 15 1-12/ 15
6GT2 821-5AC40, RS232 (ASCII)
(0.04-0.47/ 0.59) (0.04-0.47/ 0.59)
6GT2821-5AC32 / -5BC32, IO-Link*
6GT2 398-1CD40-0AX0, ANT 3 28 x 50 x 10
RF250R ANT 3S
6GT2 821-5AC10, RS422 0-2/ 3 0-2/ 3 0-3/ 4 0-3/ 4
6GT2 821-5AC40, RS232 (ASCII)
(0-0.08/ 0.12) (0-0.08/ 0.12) (0-0.12/ 0.16) (0-0.12/ 0.16)
6GT2821-5AC32 / -5BC32, IO-Link*
6GT2 398-1CD60-0AX0, ANT 3S 28 x 50 x 10
RF250R ANT 8
6GT2 821-5AC10, RS422 0-2/ 3 0-3/ 4 0-3/ 4 0-3/ 4
6GT2 821-5AC40, RS232 (ASCII) (0-0.08/ 0.12) (0-0.12/ 0.16) (0-0.12/ 0.16) (0-0.12/ 0.16)
6GT2821-5AC32 / -5BC32, IO-Link*
6GT2 398-1CF10, ANT 8 Ø8 x 40
RF250R ANT 12
6GT2 821-5AC10, RS422 0-3/ 4 0-4/ 5 0-3/ 4 0-3/ 4 0-7/ 10 1-7/ 9
6GT2 821-5AC40, RS232 (ASCII)
(0-0.12/ 0.16) (0-0.16/ 0.2) (0-0.12/ 0.16) (0-0.12/ 0.16) (0-0.28/ 0.39) (0.04-0.28/ 0.35)
6GT2821-5AC32 / -5BC32, IO-Link*
6GT2 398-1CC00, ANT 12** *** Ø12 x 40

Accessories

Operating Distance Range (mm) / Maximum Distance for Stationary Tag (mm)
Operating Distance Range (inch) / Maximum Distance for Stationary Tag (inch)

Edition: August 2020 SIMATIC Ident Configuration Guide 7


D117 D127 D421 D521 D422 D522
RF200 Family Matrix Antennas 6GT2 600-0AG00 6GT2 600-0AF00 6GT2 600-4AE00 6GT2 600-5AE00 6GT2 600-4AF00 6GT2600-5AF00
112 byte 112 byte EEPROM 2 kbyte FRAM 8 kbyte FRAM 2 kbyte FRAM 6GT2600-5AF00-0AX0
EEPROM 8 kbyte FRAM
13.56 MHz
Passive Tags

Operational temperature range -40°C to 125°C -40°C to 125°C -40°C to 100°C -40°C to 100°C -40°C to 100°C -40°C to 100°C
Dimensions (L x W x D) mm Ø4 x 5.2 Ø 6 x 5.8 Ø10 x 4.5 Ø10 x 4.5 Ø20 x 6 Ø20 x 6 ; Ø18 x 5.2
Ingress Protection (IP) rating IP68 IPx9K IP68/ IPx9K IP67/ IPx9K IP67/ IPx9K IP68 IP68
RF250R ANT 18
6GT2 821-5AC10, RS422 0-3/ 5 0-4/ 5 1-8/ 14 1-10/ 12
6GT2 821-5AC40, RS232 (ASCII) (0-0.12/ 0.20) (0-0.16/ 0.20) (0.04-0.31/ 0.55) (0.04-0.39/ 0.47)
6GT2821-5AC32 / -5BC32, IO-Link*
6GT2 398-1CA00, ANT 18** *** Ø18 x 55
RF250R ANT 30
6GT2 821-5AC10, RS422 0-12/ 15 1-12/ 15
6GT2 821-5AC40, RS232 (ASCII) (0-0.47/ 0.59) (0.04-0.47/ 0.59)
6GT2821-5AC32 / -5BC32, IO-Link* Ø30 x 58
6GT2 398-1CD00, ANT 30**
RF260R
6GT2 821-6AC10, RS422
6GT2 821-6AC40, RS232 (ASCII) Integrated
6GT2 821-6AC32 / -6BC32, IO-Link*
75 x 75 x 41

RF280R Integrated
6GT2 821-8AC10, RS422
6GT2 821-8AC40, RS232 (ASCII) 160 x 96 x 41

Accessories

* not with Tags D5xx


** antennas also available in stainless steel: ANT12 (6GT2398-1DC10), ANT18 (6GT2398-1DA10), ANT30 (6GT2398-1DD10)
*** antennas also available with 0.6 m antenna cable; ANT12 (6GT2398-1CC10), ANT18 (6GT2398-1CA10)

Operating Distance Range (mm) / Maximum Distance for Stationary Tag (mm)
Operating Distance Range (inch) / Maximum Distance for Stationary Tag (inch)

Edition: August 2020 SIMATIC Ident Configuration Guide 8


D117 D127 D421 D521 D422 D522
RF200 Family Matrix Antennas 6GT2 600-0AG00 6GT2 600-0AF00 6GT2 600-4AE00 6GT2 600-5AE00 6GT2 600-4AF00 6GT2600-5AF00
112 byte EEPROM 112 byte EEPROM 2 kbyte FRAM 8 kbyte FRAM 2 kbyte FRAM 6GT2600-5AF00-0AX0
8 kbyte FRAM
13.56 MHz
Passive Tags

Operational temperature range -40°C to 125°C -40°C to 125°C -40°C to 100°C -40°C to 100°C -40°C to 100°C -40°C to 100°C
Dimensions (L x W x D) mm Ø4 x 5.2 Ø 6 x 5.8 Ø10 x 4.5 Ø10 x 4.5 Ø20 x 6 Ø20 x 6 ; Ø18 x 5.2
Ingress Protection (IP) rating IP68 IPx9K IP68/ IPx9K IP67/ IPx9K IP67/ IPx9K IP68 IP68

RF285R ANT D1
6GT2821-7AC12, RS232
6GT2 698-5AC00
75 x 75 x 20

ANT D5

6GT2 698-5AA10
380 x 380 x 110
ANT D6
Accessory:
Set for top rail mounting
6GK5798-8ML00-0AB3 6GT2 698-5AB00
580 x 480 x 110

RF290R ANT D1
6GT2 821-0AC12, RS232, RS422
6GT2 698-5AC00
75 x 75 x 20

ANT D5

6GT2 698-5AA10
380 x 380 x 110
ANT D6

6GT2 698-5AB00
580 x 480 x 110
ANT D10
Accessory:
Set for top rail mounting
6GK5798-8ML00-0AB3 6GT2 698-5AF00
1150 x 365 x 115
Covering hood
for ANT D6
Accessories (6GT2 690-0AD00)

Operating Distance Range (mm) / Maximum Distance for Stationary Tag (mm)
Operating Distance Range (inch) / Maximum Distance for Stationary Tag (inch)

Edition: August 2020 SIMATIC Ident Configuration Guide 9


D124 D324 D424 D524 D126 D426 D526
RF200 Family Matrix Antennas 6GT2 600-0AC10 6GT2 600-3AC00 6GT2 600-4AC00 6GT2 600-5AC00 6GT2 600-0AE00 6GT2 600-4AH00 6GT2 600-5AH00
112 byte EEPROM 992 byte EEPROM 2 kbyte FRAM 8 kbyte FRAM 112 byte EEPROM 2 kbyte FRAM 8 kbyte FRAM

13.56 MHz
Passive Tags

Operational temperature range -40°C to 180°C -40°C to 140°C -40°C to 100°C -40°C to 100°C -40°C to 100°C -40°C to 100°C -40°C to 100°C
Dimensions (L x W x D) mm Ø 27 x 4 Ø 27 x 4 Ø 27 x 4 Ø 27 x 4 Ø 50 x 3.6
Ø 50 x 3.6 Ø 50 x 3.6
Ingress Protection (IP) rating IP68/ IPx9K IP67 IP67/ IPx9K IP67/ IPx9K IP68 IP68 IP68
RF210R/ RF210M
6GT2 821-1AC10, RS422
Integrated 1-18/ 20 1-8/ 9 1-16/ 18 1-15/ 17
6GT2 821-1AC32 / -1BC32, IO-Link* (0.04-0.71/ 0.79) (0.04-0.31/ 0.35) (0.04-0.63/ 0.71) (0.04-0.59/ 0.67)
6GT2 823-0AA00, Handheld (RS422)
M18 x 71
RF220R
6GT2 821-2AC10, RS422
Integrated 1-28/ 31 2-21/ 25 2-25/ 29 2-22/ 25 2-30/ 35 2-25/ 30 2-25/ 30
6GT2 821-2AC32 / -2BC32, IO-Link*
(0.04-1.10/ 1.22) (0.08-0.83/ 0.98) (0.08-0.98/ 1.14) (0.08-0.87/ 0.98) (0.08-1.18/ 1.38) (0.08-0.98/ 1.18) (0.08-0.98/ 1.18)
M30 x 71
RF240R
6GT2 821-4AC10, RS422
Integrated 2-53/ 60 1-36/ 40 1-47/ 53 1-45/ 55 2-57/ 65 2-45/ 55 2-45/ 55
6GT2 821-4AC40, RS232 (ASCII)
(0.08-2.09/ 2.36) (0.04-1.42/ 1.57) (0.04-1.85/ 2.09) (0.04-1.77/ 2.17) (0.08-2.24/ 2.56) (0.08-1.77/ 2.17) (0.08-1.77/ 2.17)
6GT2821-4AC32 / -4BC32, IO-Link*
50 x 50 x 30
RF250R ANT 1
6GT2 821-5AC10, RS422 2-60/ 75 5-60/ 70 2-70/ 80 1-65/ 80 2-80/ 95 2-80/ 95 2-80/ 95
6GT2 821-5AC40, RS232 (ASCII)
(0.08-2.36/ 2.95) (0.20-2.36/ 2.76) (0.08-2.76/ 3.15) (0.04-2.56/ 3.15) (0.08-3.15/ 3.74) (0.08-3.15/ 3.74) (0.08/3.15/ 3.74)
6GT2821-5AC32 / -5BC32, IO-Link*
6GT2 398-1CB00, ANT 1 75 x 75 x 20
RF250R ANT 3
6GT2 821-5AC10, RS422 2-32/ 40 2-22/ 35 0-34/ 48 1-35/ 40 0-47/ 60 0-44/ 58 2-35/ 45
6GT2 821-5AC40, RS232 (ASCII)
(0.08-1.26/ 1.57) (0.08-0.87/ 1.38) (0-1.34/ 1.89) (0.04-1.38/ 1.57) (0-1.85/ 2.36) (0-1.73/ 2.28) (0.08-1.38/ 1.77)
6GT2821-5AC32 / -5BC32, IO-Link*
6GT2 398-1CD40-0AX0, ANT 3 28 x 50 x 10
RF250R ANT 3S
6GT2 821-5AC10, RS422
6GT2 821-5AC40, RS232 (ASCII)
6GT2821-5AC32 / -5BC32, IO-Link*
6GT2 398-1CD60-0AX0, ANT 3S 28 x 50 x 10
RF250R ANT 8
6GT2 821-5AC10, RS422
6GT2 821-5AC40, RS232 (ASCII)
6GT2821-5AC32 / -5BC32, IO-Link*
6GT2 398-1CF10, ANT 8 Ø8 x 40
RF250R ANT 12
6GT2 821-5AC10, RS422
6GT2 821-5AC40, RS232 (ASCII)
6GT2821-5AC32 / -5BC32, IO-Link*
6GT2 398-1CC00, ANT 12** *** Ø12 x 40

Spacer Spacer Spacer Spacer Spacer Spacer Spacer


Accessories (6GT2 690-0AK00) (6GT2 690-0AK00) (6GT2 690-0AK00) (6GT2 690-0AK00) (6GT2 690-0AL00) (6GT2 690-0AL00) (6GT2 690-0AL00)

Operating Distance Range (mm) / Maximum Distance for Stationary Tag (mm)
Operating Distance Range (inch) / Maximum Distance for Stationary Tag (inch)

Edition: August 2020 SIMATIC Ident Configuration Guide 10


D124 D324 D424 D524 D126 D426 D526
RF200 Family Matrix Antennas 6GT2 600-0AC10 6GT2 600-3AC00 6GT2 600-4AC00 6GT2 600-5AC00 6GT2 600-0AE00 6GT2 600-4AH00 6GT2 600-5AH00
112 byte EEPROM 992 byte EEPROM 2 kbyte FRAM 8 kbyte FRAM 112 byte EEPROM 2 kbyte FRAM 8 kbyte FRAM

13.56 MHz
Passive Tags

Operational temperature range -40°C to 180°C -40°C to 140°C -40°C to 100°C -40°C to 100°C -40°C to 100°C -40°C to 100°C -40°C to 100°C
Dimensions (L x W x D) mm Ø 27 x 4 Ø 27 x 4 Ø 27 x 4 Ø 27 x 4 Ø 50 x 3.6
Ø 50 x 3.6 Ø 50 x 3.6
Ingress Protection (IP) rating IP68/ IPx9K IP67 IP67/ IPx9K IP67/ IPx9K IP68 IP68 IP68
RF250R ANT 18
6GT2 821-5AC10, RS422 0-24/ 37 1-18/ 27 1-27/ 36 1-25/ 30
6GT2 821-5AC40, RS232 (ASCII)
(0-0.94/ 1.46) (0.04-0.71/ 1.06) (0.04-1.06/ 1.42) (0.04-0.98/ 1.18)
6GT2821-5AC32 / -5BC32, IO-Link*
6GT2 398-1CA00, ANT 18** *** Ø18 x 55
RF250R ANT 30
6GT2 821-5AC10, RS422 1-35/ 48 1-22/ 35 0-34/ 48 1-35/ 40 0-47/ 60 0-44/ 58 2-35/ 45
6GT2 821-5AC40, RS232 (ASCII) (0.08-1.38/ 1.89) (0.04-0.87/ 1.38) (0-1.34/ 1.89) (0.04-1.38/ 1.57) (0-1.85/ 2.36) 0-1.73/ 2.28) (0.08-1.38/ 1.77)
6GT2821-5AC32 / -5BC32, IO-Link*
6GT2 398-1CD00, ANT 30** Ø30 x 58
RF260R
6GT2 821-6AC10, RS422
Integrated 2-80/ 85 2-60/ 70 2-60/ 70 2-60/ 70 2-75/ 100 2-70/ 85 2-70/ 85
6GT2 821-6AC40, RS232 (ASCII)
(0.08-3.15/ 3.35) (0.08-2.36/ 2.76) (0.08-2.36/ 2.76) (0.08-2.36/ 2.76) (0.08-2.95/ 3.94) (0.08-2.76/ 3.35) (0.08-2.76/ 3.35)
6GT2 821-6AC32 / -6BC32, IO-Link*
75 x 75 x 41

RF280R Integrated 2-110/ 130 2-85/ 110 2-100/ 140 2-110/ 130 2-135/ 160 2-145/ 175 2-135/ 165
6GT2 821-8AC10, RS422
(0.08-4.33/ 5.12) (0.08-3.35/ 4.33) (0.08-3.94/ 5.51) (0.08-4.33/ 5.12) (0.08-5.31/ 6.3) (0.08-5.71/ 6.89) (0.08-5.31/ 6.5)
6GT2 821-8AC40, RS232 (ASCII)
160 x 96 x 41
Accessories
Spacer Spacer Spacer Spacer Spacer Spacer Spacer
(6GT2 690-0AK00) (6GT2 690-0AK00) (6GT2 690-0AK00) (6GT2 690-0AK00) (6GT2 690-0AL00) (6GT2 690-0AL00) (6GT2 690-0AL00)

* not with Tags D5xx


** antennas also available in stainless steel: ANT12 (6GT2398-1DC10), ANT18 (6GT2398-1DA10), ANT30 (6GT2398-1DD10)
*** antennas also available with 0.6 m antenna cable; ANT12 (6GT2398-1CC10), ANT18 (6GT2398-1CA10)

Operating Distance Range (mm) / Maximum Distance for Stationary Tag (mm)
Operating Distance Range (inch) / Maximum Distance for Stationary Tag (inch)

Edition: August 2020 SIMATIC Ident Configuration Guide 11


D124 D324 D424 D524 D126 D426 D526
RF200 Family Matrix Antennas 6GT2 600-0AC10 6GT2 600-3AC00 6GT2 600-4AC00 6GT2 600-5AC00 6GT2 600-0AE00 6GT2 600-4AH00 6GT2 600-5AH00
112 byte EEPROM 992 byte EEPROM 2 kbyte FRAM 8 kbyte FRAM 112 byte EEPROM 2 kbyte FRAM 8 kbyte FRAM

13.56 MHz
Passive Tags

Operational temperature range -40°C to 180°C -40°C to 140°C -40°C to 100°C -40°C to 100°C -40°C to 100°C -40°C to 100°C -40°C to 100°C
Dimensions (L x W x D) mm Ø 27 x 4 Ø 27 x 4 Ø 27 x 4 Ø 27 x 4 Ø 50 x 3.6
Ø 50 x 3.6 Ø 50 x 3.6
Ingress Protection (IP) rating IP68/ IPx9K IP67 IP67/ IPx9K IP67/ IPx9K IP68 IP68 IP68
RF285R ANT D1
6GT2821-7AC12, RS232 0-100/140 0-90/130 0-90/130 0-90/130 5-110/150 5-100/140 5-100/140
(0-3.94/ 5.51) (0-3.54/ 5.12) (0-3.54/ 5.12) (0-3.54/ 5.12) (0.20-4.34/ 5.91) (0.20-3.94/ 5.51) (0.20-3.94/ 5.51)
6GT2 698-5AC00
75 x 75 x 20
ANT D5
0-180/240 0-150/200 0-180/240 0-180/240 0-300/380 0-250/320 0-250/320
(0-7.09/ 9.45) (0-5.91/ 7.87) (0-7.09/ 9.45) (0-7.09/ 9.45) (0-11.81/ 14.96) (0-9.84/ 12.60) (0-9.84/ 12.60)
6GT2 698-5AA10
380 x 380 x 110
ANT D6

Accessory:
0-200/280 0-180/240 0-200/280 0-200/250 0-350/450 0-300/380 0-300/380
Set for top rail mounting (0-7.87/ 11) (0-7.09/ 9.45) (0-7.87/ 11) (0-7.87/ 9.84) (0-13.78/ 17.72) (0-11.81/ 14.96) (0-11.81/ 14.96)
6GT2 698-5AB00
6GK5798-8ML00-0AB3 580 x 480 x 110
RF290R ANT D1
6GT2 821-0AC12, RS232, RS422
0-100/ 140 0-90/ 130 0-90/ 130 0-90/ 130 5-110/150 5-100/ 140 5-100/ 140
6GT2 698-5AC00 (0-3.94/ 5.51) (0-3.54/ 5.12) (0-3.54/ 5.12) (0.00-3.54/ 5.12) (0.20-4.34/ 5.91) (0.20-3.94/ 5.51) (0.20-3.94/ 5.51)
75 x 75 x 20
ANT D5
0-200/ 280 0-200/ 280 0-200/ 280 0-200/ 280 0-350/ 400 0-300/ 350 0-300/ 350
6GT2 698-5AA10 (0-7.87/ 11) (0-7.87/ 11) (0-7.87/ 11) (0-7.87/ 11) (0-13.78/ 15.75) (0-11.81/ 13.78) (0-11.81/ 13.78)
380 x 380 x 110
ANT D6
0-220/ 300 0-200/ 280 0-220/ 300 0-220/ 300 0-400/ 500 0-350/ 400 0-350/ 400
6GT2 698-5AB00 (0-8.66/ 11.81) (0-7.87/ 11) (0-8.66/ 11.81) (0-8.66/ 11.81) (0-15.75/ 19.69) (0-13.78/ 15.75) (0-13.78/ 15.75)
580 x 480 x 110
ANT D10
Accessory: 0-200/ 280 0-200/ 280 0-200/ 280 0-220/ 300 0-400/ 500 0-350/ 400 0-350/ 400
Set for top rail mounting (0-7.87/ 11) (0-7.87/ 11) (0-7.87/ 11) (0-8.66/ 11.81) (0-15.75/ 19.69) (0-13.78/ 15.75) (0-13.78/ 15.75)
6GK5798-8ML00-0AB3 6GT2 698-5AF00
1150 x 365 x 115
Accessories
Covering hood
for ANT D6 Spacer Spacer Spacer Spacer Spacer Spacer Spacer
(6GT2 690-0AK00) (6GT2 690-0AK00) (6GT2 690-0AK00) (6GT2 690-0AK00) (6GT2 690-0AL00) (6GT2 690-0AL00) (6GT2 690-0AL00)
(6GT2 690-0AD00)

Operating Distance Range (mm) / Maximum Distance for Stationary Tag (mm)
Operating Distance Range (inch) / Maximum Distance for Stationary Tag (inch)

Edition: August 2020 SIMATIC Ident Configuration Guide 12


D423 D425 D525 D428 D528 D139 D339
RF200 Family Matrix Antennas 6GT2 600-4AA00 6GT2 600-4AG00 6GT2 600-5AG00 6GT2 600-4AK00-0AX0 6GT2600-5AK00 6GT2 600-0AA10 6GT2600-3AA10
2 kbyte FRAM 2 kbyte FRAM 8 kbyte FRAM 2 kbyte FRAM 8 kbyte FRAM 112 byte EEPROM 992 byte EEPROM

13.56 MHz
Passive Tags

Operational temperature range -40°C to 100°C -40°C to 125°C -40°C to 125°C -40°C to 125°C -40°C to 125°C -40°C to 220°C -40°C to 220°C
Dimensions (L x W x D) mm Ø 30 x 8 Ø 24 x 10 Ø 24 x 10 Ø 24 x 20 Ø 24 x 20 Ø 85 x 15 Ø 85 x 15
Ingress Protection (IP) rating IP68/ IPx9K IP68/ IPx9K IP68/ IPx9K IP68/ IPx9K IP68/ IPx9K IP68/IPx9K IP68/IPx9K
RF210R/ RF210M
6GT2 821-1AC10, RS422
Integrated 2-10/ 12 1-6/ 7 1-6/ 7 1-10/ 11 1-10/ 11
6GT2 821-1AC32 / -1BC32, IO-Link*
(0,08-0.39/ 0.47) (0.04-0.24/ 0.28) (0.04-0.24/ 0.28) (0.04-0.39/ 0.43) (0.04-0.39/ 0.43)
6GT2 823-0AA00, Handheld (RS422)
M18 x 71
RF220R
6GT2 821-2AC10, RS422 2-24/ 28 1-11/ 13 1-11/ 13 1-18/ 21 1-15/ 20
6GT2 821-2AC32 / -2BC32, IO-Link* Integrated
(0,08-0.95/ 1.1) (0.04-0.43/ 0.51) (0.04-0.43/ 0.51) (0.04-0.71/ 0.83) (0.04-0.59/ 0.79)
M30 x 71
RF240R
6GT2 821-4AC10, RS422
Integrated 2-35/ 40 1-15/ 17 1-15/ 17 1-30/ 34 1-30/ 35
6GT2 821-4AC40, RS232 (ASCII)
(0.08-1.37/ 1.57) (0.04-0.59/ 0.67) (0.04-0.59/ 0.67) (0.04-1.18/ 1.34) (0.04-1.18/ 1.38 )
6GT2821-4AC32 / -4BC32, IO-Link*
50 x 50 x 30

RF250R ANT 1
6GT2 821-5AC10, RS422 2-35/ 45 2-25/ 30 2-25/ 30 2-40/ 50 2-40/ 45 5-90/ 105 2-85/ 100
6GT2 821-5AC40, RS232 (ASCII)
(0.08-1.37/ 1.77) (0.08-0.98/ 1.18) (0.08-0.98/ 1.18) (0.08-1.57/ 1.97) (0.08-1.57/ 1.77) (0.2-3.54/ 4.13) (0.08-3.35/ 3.94)
6GT2821-5AC32 / -5BC32, IO-Link*
6GT2 398-1CB00, ANT 1 75 x 75 x 20
RF250R ANT 3
6GT2 821-5AC10, RS422 0-24/ 30 0-12/ 20 1-12/ 20 1-20/ 32 1-20/ 25
6GT2 821-5AC40, RS232 (ASCII)
(0-0.95/ 1.18) (0-0.47/ 0.79) (0.04-0.47/ 0.79) (0.04-0.79/ 1.26) (0.04-0.79/ 0.98)
6GT2821-5AC32 / -5BC32, IO-Link*
6GT2 398-1CD40-0AX0, ANT 3 28 x 50 x 10
RF250R ANT 3S
6GT2 821-5AC10, RS422
6GT2 821-5AC40, RS232 (ASCII)
6GT2821-5AC32 / -5BC32, IO-Link*
6GT2 398-1CD60-0AX0, ANT 3S 28 x 50 x 10
RF250R ANT 8
6GT2 821-5AC10, RS422
6GT2 821-5AC40, RS232 (ASCII)
6GT2821-5AC32 / -5BC32, IO-Link*
6GT2 398-1CF10, ANT 8 Ø8 x 40
RF250R ANT 12
6GT2 821-5AC10, RS422 0-8/ 10 1-8/ 10 1-8/ 12 1-8/ 12
6GT2 821-5AC40, RS232 (ASCII)
(0.0-0.31/ 0.39) (0.04-0.31/ 0.39) (0.04-0.31/ 0.47) (0.04-0.31/ 0.47)
6GT2821-5AC32 / -5BC32, IO-Link*
6GT2 398-1CC00, ANT 12** *** Ø12 x 40
Spacer Spacer
(6GT2 690-0AA00) (6GT2 690-0AA00)

Accessories Mounting cover Mount for quick tag Mount for quick tag
(6GT2 690-0AE00) exchange exchange
(6GT2 690-0AH00 - long) (6GT2 690-0AH00 - long)
(6GT2 690-0AH10 – short) (6GT2 690-0AH10 – short)

Operating Distance Range (mm) / Maximum Distance for Stationary Tag (mm)
Operating Distance Range (inch) / Maximum Distance for Stationary Tag (inch)

Edition: August 2020 SIMATIC Ident Configuration Guide 13


D423 D425 D525 D428 D528 D139 D339
RF200 Family Matrix Antennas 6GT2 600-4AA00 6GT2 600-4AG00 6GT2 600-5AG00 6GT2 600-4AK00-0AX0 6GT2600-5AK00 6GT2 600-0AA10 6GT2600-3AA10
2 kbyte FRAM 2 kbyte FRAM 8 kbyte FRAM 2 kbyte FRAM 8 kbyte FRAM 112 byte EEPROM 992 byte EEPROM

13.56 MHz
Passive Tags

Operational temperature range -40°C to 100°C -40°C to 125°C -40°C to 125°C -40°C to 125°C -40°C to 125°C -40°C to 220°C -40°C to 220°C
Dimensions (L x W x D) mm Ø 30 x 8 Ø 24 x 10 Ø 24 x 10 Ø 24 x 20 Ø 24 x 20 Ø 85 x 15 Ø 85 x 15
Ingress Protection (IP) rating IP68/ IPx9K IP68/ IPx9K IP68/ IPx9K IP68/ IPx9K IP68/ IPx9K IP68/IPx9K IP68/IPx9K
RF250R ANT 18
6GT2 821-5AC10, RS422 1-15/ 18 1-11/ 16 1-11/ 16 1-18/ 25 1-15/ 20
6GT2 821-5AC40, RS232 (ASCII)
(0.04-0.59/ 0.71) (0.04-0.43/ 0.63) (0.04-0.43/ 0.63) (0.04-0.71/ 0.98) (0.04-0.59/ 0.79)
6GT2821-5AC32 / -5BC32, IO-Link*
6GT2 398-1CA00, ANT 18** *** Ø18 x 55
RF250R ANT 30
6GT2 821-5AC10, RS422 0-18/ 26 1-12/ 20 1-12/ 20 1-20/ 32 1-20/ 25
6GT2 821-5AC40, RS232 (ASCII) (0-0.71/ 1.02) (0.04-0.47/ 0.79) (0.04-0.47/ 0.79) (0.04-0.79/ 1.26) (0.04-0.79/ 0.98)
6GT2821-5AC32 / -5BC32, IO-Link*
6GT2 398-1CD00, ANT 30** Ø30 x 58
RF260R
6GT2 821-6AC10, RS422
Integrated 2-40/ 45 2-40/ 45 2-35/ 40 2-80/ 110 5-65/ 80
6GT2 821-6AC40, RS232 (ASCII)
(0.08-1.57/ 1.77) (0.08-1.57/ 1.77) (0.08-1.38/ 1.57) (0.08-3.15/ 4.33) (0.20-2.56/ 3.15)
6GT2 821-6AC32 / -6BC32, IO-Link*
75 x 75 x 41

RF280R Integrated 5-60/ 70 2-30/ 40 2-30/ 40 2-60/ 88 2-60/ 85 5-150/ 190 5-150/ 170
6GT2 821-8AC10, RS422
(0.20-2.36/ 2.76) (0.08-1.18/ 1.57) (0.08-1.18/ 1.57) (0.08-2.36/ 3.46) (0.08-2.36/ 3.35) (0.20-5.91/ 7.48) (0.20-5.91/ 6.69)
6GT2 821-8AC40, RS232 (ASCII)
160 x 96 x 41
Spacer Spacer
(6GT2 690-0AA00) (6GT2 690-0AA00)
Mounting cover Mount for quick tag Mount for quick tag
Accessories
(6GT2 690-0AE00) exchange exchange
(6GT2 690-0AH00 - long) (6GT2 690-0AH00 - long)
(6GT2 690-0AH10 – short) (6GT2 690-0AH10 – short)

* not with Tags D5xx


** antennas also available in stainless steel: ANT12 (6GT2398-1DC10), ANT18 (6GT2398-1DA10), ANT30 (6GT2398-1DD10)
*** antennas also available with 0.6 m antenna cable; ANT12 (6GT2398-1CC10), ANT18 (6GT2398-1CA10)

Operating Distance Range (mm) / Maximum Distance for Stationary Tag (mm)
Operating Distance Range (inch) / Maximum Distance for Stationary Tag (inch)

Edition: August 2020 SIMATIC Ident Configuration Guide 14


D423 D425 D525 D428 D528 D139 D339
RF200 Family Matrix Antennas 6GT2 600-4AA00 6GT2 600-4AG00 6GT2 600-5AG00 6GT2 600-4AK00-0AX0 6GT2600-5AK00 6GT2 600-0AA10 6GT2600-3AA10
2 kbyte FRAM 2 kbyte FRAM 8 kbyte FRAM 2 kbyte FRAM 8 kbyte FRAM 112 byte EEPROM 992 byte EEPROM

13.56 MHz
Passive Tags

Operational temperature range -40°C to 100°C -40°C to 125°C -40°C to 125°C -40°C to 125°C -40°C to 125°C -40°C to 220°C -40°C to 220°C
Dimensions (L x W x D) mm Ø 30 x 8 Ø 24 x 10 Ø 24 x 10 Ø 24 x 20 Ø 24 x 20 Ø 85 x 15 Ø 85 x 15
Ingress Protection (IP) rating IP68/ IPx9K IP68/ IPx9K IP68/ IPx9K IP68/ IPx9K IP68/ IPx9K IP68/IPx9K IP68/IPx9K
RF285R ANT D1
6GT2821-7AC12, RS232 10-60/85 0-55/80 0-55/80 5-160/220 5-130/170
(0.39-2.36/ 3.35) (0-2.17/ 3.15) (0-2.17/ 3.15) (0.20-6.30/ 8.66) (0.20-5.12/ 6.69)
6GT2 698-5AC00
75 x 75 x 20
ANT D5
0-350/450 0-280/350
(0-13.78/ 17.72) (0-11.02/ 13.78)
6GT2 698-5AA10
380 x 380 x 110
ANT D6

Accessory:
0-450/550 0-350/450
Set for top rail mounting (0-17.72/ 21.65) (0-13.78/ 17.72)
6GT2 698-5AB00
6GK5798-8ML00-0AB3 580 x 480 x 110

RF290R ANT D1
6GT2 821-0AC12, RS232, RS422 10-60/85 0-55/ 80 0-55/ 80 5-160/ 220 5-130/170
(0.39-2.36/ 3.35) (0-2.17/ 3.15) (0-2.17/ 3.15) (0.20-6.30/ 8.66) (0.20-5.12/ 6.69)
6GT2 698-5AC00
75 x 75 x 20
ANT D5
0-400/ 500 0-300/ 380
(0-15.75/ 19.69) (0-11.81/ 15.00)
6GT2 698-5AA10
380 x 380 x 110
ANT D6
0-500/ 600 0-400/ 480
(0-19.69/ 23.62) (0-15.75/ 18.9)
6GT2 698-5AB00
580 x 480 x 110
ANT D10
Accessory: 0-450/ 550 0-300/ 380
Set for top rail mounting (0-17.72/ 21.65) (0-11.81/ 15.00)
6GK5798-8ML00-0AB3 6GT2 698-5AF00
1150 x 365 x 115
Spacer Spacer
Covering hood (6GT2 690-0AA00) (6GT2 690-0AA00)

for ANT D6 Mounting cover Mount for quick tag Mount for quick tag
Accessories
(6GT2 690-0AD00) (6GT2 690-0AE00) exchange exchange
(6GT2 690-0AH00 - long) (6GT2 690-0AH00 - long)
(6GT2 690-0AH10 – short) (6GT2 690-0AH10 – short)

Operating Distance Range (mm) / Maximum Distance for Stationary Tag (mm)
Operating Distance Range (inch) / Maximum Distance for Stationary Tag (inch)

Edition: August 2020 SIMATIC Ident Configuration Guide 15


RF200 System Interfaces
PROFINET & OPC UA & Ethernet/IP & TCP/IP Reader Tags
powered through connection cable
Communication Modules
A maximum of
D100 (6GT2 600-0AD10)
1 reader at RF185C, D200 (6GT2 600-1AD00 -0AX0)
2 readers at RF186C/CI, D400 (6GT2 600-4AD00)
4 readers at RF188C/CI
of RF2x0R may be connected RF210R RF210M

+ +
D421 (6GT2 600-4AE00)
RF185C RF186C RF188C (6GT2 821-1AC10) (6GT2 823-0AA00) D521 (6GT2 600-5AE00)
(6GT2 002-0JE10) (6GT2 002-0JE20) (6GT2 002-0JE40) 2 m = 6GT2 891-4FH20 5 m = 6GT2 891-4FH50
10 m = 6GT2 891-4FN10 20 m = 6GT2 891-4FN20
50 m = 6GT2 891-4FN50*
D422 (6GT2 600-4AF00)
Reader connector 90° angled: D522 (6GT2 600-5AF00)

Additional IOs
2 m = 6GT2 891-4JH20 5 m = 6GT2 891-4JH50 RF220R D522 (6GT2 600-5AF00-0AX0)
10 m = 6GT2 891-4JN10 (6GT2 821-2AC10)
ANT 1
D124 (6GT2 600-0AC10)
(6GT2 398-1CB00)
D324 (6GT2 600-3AC00)
Types of IO-Link ANT 3
+ RF18xCI to sensor
+ IO module
IO-extension module
RF240R
(6GT2 821-4AC10)
(6GT2 398-1CD40-0AX0)
ANT 3S
D424 (6GT2 600-4AC00)
D524 (6GT2 600-5AC00)

RF186CI RF188CI Sensor cable from 6ES7 14….. (up to 8xDI + 8xDO) (6GT2 398-1CD60-0AX0)

+
(6GT2 002-0JE50) (6GT2 002-0JE60) 0.5 to 15 m available ANT 8
See page 76 for detailed information D423 (6GT2 600-4AA00)
(e.g. 2 m = 6XV1801-2CH20) (6GT2 398-1CF10)
ANT 12
(6GT2 398-1CC00)
RF250R D425 (6GT2 600-4AG00)
Or one (6GT2 821-5AC10)
(6GT2398-1DC10 steel)
D525 (6GT2 600-4AB00)
Standard sensor ANT 18
(6GT2 398-1CA00)
Or one (6GT2398-1DA10 steel) D127 (6GT2 600-4AF00)
ANT 30 D117 (6GT2 398-1CF00)
Actor
(6GT2 398-1CD00)
RF260R (6GT2398-1DD10 steel)
(6GT2 821-6AC10)
D428 (6GT2 600-4AK00-0AX0)
D528 (6GT2600-5AK00)

RF280R D126 (6GT2 600-0AE00)


(6GT2 821-8AC10) D426 (6GT2 600-4AH00)
ANT D1 D526 (6GT2 600-5AH00)
(6GT2 698-5AC00)

ANT D5
+ (6GT2 698-5AA10)

ANT D6 D139 (6GT2 600-0AA10)


D339 (6GT2 600-3AA10)
(6GT2 698-5AB00)

RF290R ANT D10


(6GT2 821-0AC12) (6GT2 698-5AF00)
D160 (6GT2 600-0AB10)
D460 (6GT2 600-4AB00)
D560 (6GT2600-5AB00)

Opt. Splitter
w/ D5, D6 only
(6GT2 690-0AC00) D165 (6GT2 600-1AB00-0AX0)
* Cable improper for RF290R usage due to length limitation of 20 m D261 (6GT2 600-1AA01-0AX0)

Edition: August 2020 SIMATIC Ident Configuration Guide 16


RF200 System Interfaces

SIMATIC PLC Reader Tags


+ +
A maximum of 1 readers may be connected
powered through connection cable
S7-1200 RF120C to RF2x0R
2 m = 6GT2 091-4LH20 5 m = 6GT2 091-4LH50
D100 (6GT2 600-0AD10)
10m = 6GT2 091-4LN10
D200 (6GT2 600-1AD00 -0AX0)
And extension cables: D400 (6GT2 600-4AD00)
2 m = 6GT2 891-4FH20 5 m = 6GT2 891-4FH50
RF120C 10 m = 6GT2 891-4FN10 20 m = 6GT2 891-4FN20
6GT2 002-0LA00 RF210R RF210M D421 (6GT2 600-4AE00)
50 m = 6GT2 891-4FN50* (6GT2 821-1AC10)
2 m = 6GT2 891-4JH20 Reader connector 90° angled (6GT2 823-0AA00) D521 (6GT2 600-5AE00)
Up to 3 x 120C modules
5 m = 6GT2 891-4JH50 Reader connector 90° angled
per S7-1200 rack
10 m = 6GT2 891-4JN10 Reader connector 90° angled

SIMATIC PLC D422 (6GT2 600-4AF00)


D522 (6GT2 600-5AF00)
RF220R D522 (6GT2 600-5AF00-0AX0)

S7-300 Rack or
+ + +
A maximum of 2 readers may be connected (6GT2 821-2AC10)
ANT 1
ASM 475 to RF2x0R
S7-400 via ET 200M (6GT2 398-1CB00)
D124 (6GT2 600-0AC10)
D324 (6GT2 600-3AC00)
2 m = 6GT2 891-4EH20 5 m = 6GT2 891-4EH50 ANT 3
(DP-V1/PN-IO) And extension cables:
RF240R
(6GT2 398-1CD40-0AX0)
D424 (6GT2 600-4AC00)
D524 (6GT2 600-5AC00)
2 m = 6GT2 891-4FH20 5 m = 6GT2 891-4FH50 ANT 3S
ASM 475 + Front connector 10 m = 6GT2 891-4FN10 20 m = 6GT2 891-4FN20 (6GT2 821-4AC10)
(6GT2 002-0GA10) + (6ES7 392-1AJ00-0AA0) (6GT2 398-1CD60-0AX0)
50 m = 6GT2 891-4FN50*

+
2 m = 6GT2 891-4JH20 Reader connector 90° angled ANT 8 D423 (6GT2 600-4AA00)
Accessories: 5 m = 6GT2 891-4JH50 Reader connector 90° angled (6GT2 398-1CF10)
Connecting element (6ES7 390-5AA00-0AA0) 10 m = 6GT2 891-4JN10 Reader connector 90° angled
Terminal element (6ES7 390-5BA00-0AA0) ANT 12
(6GT2 398-1CC00)
RF250R (6GT2398-1DC10 steel) D425 (6GT2 600-4AG00)

ET 200pro ET 200pro PROFIBUS DP-V1


(6GT2 821-5AC10)
ANT 18
(6GT2 398-1CA00)
D525 (6GT2 600-4AB00)

via PROFIBUS Interface module (6GT2398-1DA10 steel)


ANT 30
D127 (6GT2 600-4AF00)
D117 (6GT2 398-1CF00)

or PROFINET (6GT2 398-1CD00)

+ + +
ET 200pro PROFINET A maximum of 2 readers may be connected
RF260R (6GT2398-1DD10 steel)
Interface module
or S7 PLC RF170C to RF2x0R
2 m = 6GT2 891-4FH20 5 m = 6GT2 891-4FH50
(6GT2 821-6AC10)
D428 (6GT2 600-4AK00-0AX0)
D528 (6GT2600-5AK00)
ET 200pro PROFINET 10 m = 6GT2 891-4FN10 20 m = 6GT2 891-4FN20
CPU module RF170C 50 m = 6GT2 891-4FN50*
Communication module
Up to 9 x 170C (6GT2002-0HD01) Reader connector 90° angled
modules per Connection block 2 m = 6GT2 891-4JH20 5 m = 6GT2 891-4JH50
RF280R D126 (6GT2 600-0AE00)
ET 200pro rack (6GT2002-1HD01) 10 m = 6GT2 891-4JN10
(6GT2 821-8AC10) ANT D1 D426 (6GT2 600-4AH00)
(6GT2 698-5AC00) D526 (6GT2 600-5AH00)

ANT D5
PROFIBUS + (6GT2 698-5AA10)

A maximum of 2 readers may be connected ANT D6

+ +
D139 (6GT2 600-0AA10)
(6GT2 698-5AB00) D339 (6GT2 600-3AA10)
Optional:
RF166C to RF2x0R
cable for using the wbm ANT D10
2 m = 6GT2 891-4FH20 5 m = 6GT2 891-4FH50 RF290R (6GT2 698-5AF00)
6XV1871-5Txxx (6GT2 821-0AC12)
10 m = 6GT2 891-4FN10 20 m = 6GT2 891-4FN20
D160 (6GT2 600-0AB10)
50 m = 6GT2 891-4FN50*
D460 (6GT2 600-4AB00)
D560 (6GT2600-5AB00)
Reader connector 90° angled
RF166C (DP-V1) 2 m = 6GT2 891-4JH20 5 m = 6GT2 891-4JH50 Opt. Splitter
Communication Module 10 m = 6GT2 891-4JN10
w/ D5, D6 only
(6GT2 002-0EE20) (6GT2 690-0AC00) D165 (6GT2 600-1AB00-0AX0)
* Cable improper for RF290R usage due to length limitation of 20 m D261 (6GT2 600-1AA01-0AX0)

Edition: August 2020 SIMATIC Ident Configuration Guide 17


RF200 System Interfaces

RS232 / ASCII Reader Tags


with external power supply at Y-cable

D100 (6GT2 600-0AD10)


ANT 1 D200 (6GT2 600-1AD00 -0AX0)
(6GT2 398-1CB00) D400 (6GT2 600-4AD00)
ANT 3
RF240R (6GT2 398-1CD40-0AX0)

+
D421 (6GT2 600-4AE00)
1 Reader per COM port may be connected (6GT2 821-4AC40)
ANT 3S D521 (6GT2 600-5AE00)
Wide-Range power supply + 5 m cable
6GT2 898-0ACxx + 6GT2 491-1HH50 + RS 232 cable for RF2x0R
5 m = 6GT2 891-4KH50
Extension cables: 5 m = 6GT2 891-4FH50 +
(6GT2 398-1CD60-0AX0)
ANT 8
(6GT2 398-1CF10) D422 (6GT2 600-4AF00)
10 m = 6GT2 891-4FN10 ANT 12 D522 (6GT2 600-5AF00)
RF250R (6GT2 398-1CC00) D522 (6GT2 600-5AF00-0AX0)
Simple text based protocol (6GT2 821-5AC40) (6GT2398-1DC10 steel)
ANT 18
(6GT2 398-1CA00) D124 (6GT2 600-0AC10)
(6GT2398-1DA10 steel) D324 (6GT2 600-3AC00)
ANT 30 D424 (6GT2 600-4AC00)
(6GT2 398-1CD00) D524 (6GT2 600-5AC00)
(6GT2398-1DD10 steel)
RF260R
(6GT2 821-6AC40)
D423 (6GT2 600-4AA00)

D425 (6GT2 600-4AG00)


D525 (6GT2 600-4AB00)

RF280R
D127 (6GT2 600-4AF00)
(6GT2 821-8AC40)
D117 (6GT2 398-1CF00)

RS232 Reader D428 (6GT2 600-4AK00-0AX0)


with external power supply at Y-cable D528 (6GT2600-5AK00)

ANT D1
(6GT2 698-5AC00)
D126 (6GT2 600-0AE00)

+
1 Reader per COM port may be connected ANT D5 D426 (6GT2 600-4AH00)
D526 (6GT2 600-5AH00)

+
(6GT2 698-5AA10)

+
Wide-Range power supply + 5 m cable RS 232 cable for RF2x0R RF285R*
5 m = 6GT2 891-4KH50 ANT D6
(6GT2 821-7AC12)
6GT2 898-0ACxx + 6GT2 491-1HH50 (6GT2 698-5AB00)
Extension cables: 5 m = 6GT2 891-4FH50
10 m = 6GT2 891-4FN10 ANT D10 D139 (6GT2 600-0AA10)
(6GT2 698-5AF00) D339 (6GT2 600-3AA10)
RF290R Tool for Configuration on DVD
Binary based protocol or Scanmode Opt. Splitter
w/ D5, D6 only
(6GT2 690-0AC00) D160 (6GT2 600-0AB10)
D460 (6GT2 600-4AB00)
D560 (6GT2600-5AB00)
RF290R
optional antenna cables
(6GT2 821-0AC12)
10 m = 6GT2691-0CN10
7.2 m extension = 6GT2691-0DH72
D165 (6GT2 600-1AB00-0AX0)
*do not use with D10 ; do not use with Splitter D261 (6GT2 600-1AA01-0AX0)

Edition: August 2020 SIMATIC Ident Configuration Guide 18


RF200 System Interfaces

IO-Link: S7-1200 Reader Tags


+ + +
A maximum of 4 (1*) readers may be connected powered through connection cable
S7-1200 to RF2x0R IO-Link
5 m = 6GT2 891-4LH50 10 m = 6GT2 891-4LN10 D100 (6GT2 600-0AD10)
D200 (6GT2 600-1AD00 -0AX0)
SM1278 IO-Link D400 (6GT2 600-4AD00)
S7-1200 (6ES7278-4BD32-0XB0)
D421 (6GT2 600-4AE00)
IO-Link: ET 200SP
RF210R IO-Link
via PROFIBUS
+ + +
A maximum of 4 (1**) readers may be connected
6GT2 821-1AC32 (8 Byte)
ET 200SP to RF2x0R IO-Link 6GT2 821-1BC32 (32 Byte)
or PROFINET D422 (6GT2 600-4AF00)
5 m = 6GT2 891-4LH50 10 m = 6GT2 891-4LN10
or S7 PLC ET 200SP head module
Electronic module
(6ES7 137-6BD00-0BA0)

IO-Link: ET 200S
D124 (6GT2 600-0AC10)
D324 (6GT2 600-3AC00)
RF220R IO-Link
+
A maximum of 4 (0*) readers may be connected
+ +
D424 (6GT2 600-4AC00)
via PROFIBUS 6GT2 821-2AC32 (8 Byte)
6GT2 821-2BC32 (32 Byte)
ET 200S to RF2x0R IO-Link
or PROFINET 5 m = 6GT2 891-4LH50 10 m = 6GT2 891-4LN10
or S7 PLC ET 200S head module Electronic module D423 (6GT2 600-4AA00)
(6ES7 138-4GA50-0AB0)

IO-Link: ET 200AL A maximum of 4 (1*) readers may be connected RF240R IO-Link D425 (6GT2 600-4AG00)

+ +
6GT2 821-4AC32 (8 Byte)
via PROFIBUS ET 200AL to RF2x0R IO-Link
6GT2 821-4BC32 (32 Byte)

Head module D127 (6GT2 600-4AF00)


or PROFINET PN: 6ES7-157-1AB00-0AB0
IO-Link module
(6ES7 147-5JD00-0BA0)
1.5 m = 3RK1902-4PB15-3AA0 ANT 1 D117 (6GT2 398-1CF00)
PB: 6ES7-157-1AA00-0AB0 5 m = 6GT2 891-4MH50 10 m = 6GT2 891-4MN10
(6GT2 398-1CB00)
ANT 3
(6GT2 398-1CD40-0AX0)
D428 (6GT2 600-4AK00-0AX0)

IO-Link: ET 200pro ANT 3S


(6GT2 398-1CD60-0AX0)

via PROFIBUS ANT 8


(6GT2 398-1CF10)
RF250R
or PROFINET ET 200pro PROFIBUS DP-V1 IO-Link ANT 12
D126 (6GT2 600-0AE00)
D426 (6GT2 600-4AH00)
(6GT2 398-1CC00)
or S7 PLC Interface module 6GT2 821-5AC32
(8 Byte) (6GT2398-1DC10 steel)
A maximum of 4 (1*) readers may be connected 6GT2 821-5BC32 ANT 18

+ + +
ET 200pro PROFINET (32 Byte) (6GT2 398-1CA00)
Interface module (6GT2398-1DA10 steel)
ET 200AL to RF2x0R IO-Link D139 (6GT2 600-0AA10)
ANT 30 D339 (6GT2 600-3AA10)
1.5 m = 3RK1902-4PB15-3AA0 (6GT2 398-1CD00)
ET 200pro PROFINET
5 m = 6GT2 891-4MH50 10 m = 6GT2 891-4MN10 (6GT2398-1DD10 steel)
CPU module
Up to 9 x 170C D160 (6GT2 600-0AB10)
modules per IO-Link module D460 (6GT2 600-4AB00)
ET 200pro rack (6ES7147-4JD00-0AB0)

RF260R IO-Link
*) for IO-Link reader of type 32 Byte: Some IO-Link Master permit only one or none reader per module 6GT2 821-6AC32 (8 Byte) D165 (6GT2 600-1AB00-0AX0)
**) in case of using a PROFIBUS head module at ET 200SP, only one 32 Byte reader may be connected 6GT2 821-6BC32 (32 Byte) D261 (6GT2 600-1AA01-0AX0)

Edition: August 2020 SIMATIC Ident Configuration Guide 19


RF200 System Interfaces

IO-Link: S7-1500 Reader Tags


powered through connection cable

+ + +
A maximum of 8 (7*) readers may be connected D100 (6GT2 600-0AD10)
D200 (6GT2 600-1AD00 -0AX0)
S7-1500 to RF2x0R IO-Link D400 (6GT2 600-4AD00)

5 m = 6GT2 891-4LH50 10 m = 6GT2 891-4LN10


D421 (6GT2 600-4AE00)
CM 8xIO-Link,
S7-1500 Electronic module RF210R IO-Link
(6ES7547-1JF00-0AB0) 6GT2 821-1AC32 (8 Byte)
6GT2 821-1BC32 (32 Byte) D422 (6GT2 600-4AF00)

IO-Link: PROFINET
ET 200eco PN A maximum of 4 (0*) readers may be connected D124 (6GT2 600-0AC10)
(6ES7148-6JA00-0AB0) D324 (6GT2 600-3AC00)
RF220R IO-Link D424 (6GT2 600-4AC00)
OR 6GT2 821-2AC32 (8 Byte)
6GT2 821-2BC32 (32 Byte)
ET 200eco PN A maximum of 4 readers may be connected
(6ES7148-6JD00-0AB0)
D423 (6GT2 600-4AA00)

OR
+
A maximum of 8 (7*) readers may be connected
ET 200eco PN CM 8x IO-Link, M12-L
(6ES7148-6JG00-0BB0)
+ Cables ET 200 eco PN to RF2x0R IO-Link
RF240R IO-Link
6GT2 821-4AC32 (8 Byte)
D425 (6GT2 600-4AG00)

1.5 m = 3RK1902-4PB15-3AA0 6GT2 821-4BC32 (32 Byte)


5 m = 6GT2 891-4MH50 10 m = 6GT2 891-4MN10 D127 (6GT2 600-4AF00)
ANT 1 D117 (6GT2 398-1CF00)

IO-Link: (6GT2 398-1CB00)


ANT 3
Other Master (6GT2 398-1CD40-0AX0)
ANT 3S
D428 (6GT2 600-4AK00-0AX0)

(6GT2 398-1CD60-0AX0)
ANT 8
RF250R (6GT2 398-1CF10)
D126 (6GT2 600-0AE00)
IO-Link ANT 12 D426 (6GT2 600-4AH00)
6GT2 821-5AC32 (6GT2 398-1CC00)
(8 Byte) (6GT2398-1DC10 steel)
M12 Cables for IP65 Masters
ANT 18
+
6GT2 821-5BC32

+
5 m = 6GT2 891-4MH50 10 m = 6GT2 891-4MN10
(32 Byte) (6GT2 398-1CA00)
Open end Cables for IP20 Masters (6GT2398-1DA10 steel)
D139 (6GT2 600-0AA10)
ANT 30 D339 (6GT2 600-3AA10)
5 m = 6GT2 891-4LH50 10 m = 6GT2 891-4LN10
(6GT2 398-1CD00)
(6GT2398-1DD10 steel)

D160 (6GT2 600-0AB10)


D460 (6GT2 600-4AB00)

According to www.io-link.com *) for IO-Link reader of type 32 Byte: RF260R IO-Link


6GT2 821-6AC32 (8 Byte) D165 (6GT2 600-1AB00-0AX0)
see competency-matrix for all available offers Reduced number of reader per module for some types of IO-Link Master
6GT2 821-6BC32 (32 Byte) D261 (6GT2 600-1AA01-0AX0)

Edition: August 2020 SIMATIC Ident Configuration Guide 20


RF320T RF330T RF340T RF350T RF360T RF370T RF380T
RF300 Family Matrix Antennas
6GT2 800-1CA00 6GT2 800-5BA00 20 byte EEPROM + 6GT2 800-5BD00 20 byte EEPROM + 20 Byte EEPROM + 6GT2 800-5DA00
(RF300 Tags) 20 byte
EEPROM
20 byte EEPROM
32 kbyte FRAM
6GT2 800-4BB00
8 kbyte FRAM
20 byte EEPROM
32 kbyte FRAM
6GT2 800-4AC00
8 kbyte FRAM
6GT2 800-5BE00
32 kbyte FRAM
20 byte EEPROM
32 kbyte FRAM
6GT2 800-5BB00 6GT2 800-5AC00 6GT2 800-6BE00
32 kByte FRAM 32 kbyte FRAM 64 kbyte FRAM
13.56 MHz
Passive Tags
Operational Temperature Range Suitable for
-40°C to 140°C -40°C to 100°C -40°C to 85°C -40°C to 85°C -40°C to 85°C -40°C to 85°C --40°C to 220°C
Dimensions( L x W x D) mm Dynamic
Ø 27 x 4 Ø 30 x 8 48 x 25 x 15 50 x 50 x 20 85.8 x 54.1 x 2.5 75 x 75 x 41 Ø 114 x 83
Ingress Protection (IP) Rating Operation
IP67/IPX9K IP68/IPX9K IP67/IPX9K IP68 IP67 IP68 IP68
RF310R
RS422

6GT2801-1BA10 1-23/ 26 2-18/ 21 2-36/ 41 2-47/ 53 2-60/68 2-45/ 60


6GT2801-1BA10-0AX1 (90°plate)
Integrated YES
(0.04-0.91/ 1.02) (0.08-0.71/ 0.83) (0.08-1.42/ 1.61) (0.08-1.85/ 2.09) (0.08-2.36/ 2.68) (0.08-1.77./ 2.36)
6GT2801-1BA10-0AX2 (Ex)
6GT2 801-1BA20-0AX1 (Scanmode) 55 x 75 x 30

RF340R
RS422
1-20/ 25 2-20/ 23 2-50/ 58 2-60/ 75 2-65/ 85 5-60/ 80 5-80/ 100
6GT2801-2BA10 Integrated YES
6GT2801-2BA10-0AX2 (Ex) (0.04-0.79/ 0.98) (0.08-0.79/ 0.91) (0.08-1.97/ 2.28) (0.08-2.36/ 2.95) (0.08-2.56/ 3.35) (0.20-2.36/ 3.15) (0.20-3.15/ 3.94)

75 x 75 x 41
RF350R ANT 1
RS422
1-30/ 37 2-25/ 30 2-55/ 70 2-65/ 85 2-75/ 100 5-65/ 85 5-90/ 110
6GT2801-4BA10 YES
6GT2801-4BA10-0AX2 (Ex) (0.04-1.18/ 1.46) (0.08-0.98/ 1.18) (0.08-2.16/ 2.76) (0.08-2,56/ 3.35) (0.08-2.95./ 3.94) (0.20-2.56/ 3.35) (0.20-3.54/ 4.33)
6GT2 398-1CB00 (ANT 1)
75 x 75 x 20
RF350R ANT 3
RS422
1-15 / 18 1-16 / 20 2-32/ 40 2-35/ 42
6GT2801-4BA10 NO
6GT2801-4BA10-0AX2 (Ex) (0.04-0.59/ 0.71) (0.04-0.63/ 0.79) (0.08-1.26/ 1.57) (0.08-1.38/ 1.65)
6GT2 398-1CD40-0AX0 (ANT 3)
28 x 50 x 10

RF350R ANT 3S
RS422

6GT2801-4BA10 NO
6GT2801-4BA10-0AX2 (Ex)
6GT2 398-1CD60-0AX0 (ANT 3S)
28 x 50 x 10

Holder:
(short: 6GT2 090-0QA00)
20 mm spacer (long: 6GT2 090-0QA00-
(6GT2 190-0AA00) 0AX3)
Spacer Mounting cover Cover for holder:
Accessories (6GT2 690-0AK00) (6GT2 690-0AE00) (6GT2 090-0QB00)
Fixing pocket
(6GT2 190-0AB00) All Purpose
Support
(6GT2 590-0QA00)

Operating Distance Range (mm) / Maximum Distance for Stationary Tag (mm)
Operating Distance Range (inch) / Maximum Distance for Stationary Tag (inch)

Edition: August 2020 SIMATIC Ident Configuration Guide 21


RF320T RF330T RF340T RF350T RF360T RF370T RF380T
RF300 Family Matrix Antennas
6GT2 800-1CA00 6GT2 800-5BA00 20 byte EEPROM + 6GT2 800-5BD00 20 byte EEPROM + 20 Byte EEPROM + 6GT2 800-5DA00
(RF300 Tags) 20 byte
EEPROM
20 byte EEPROM
32 kbyte FRAM
6GT2 800-4BB00
8 kbyte FRAM
20 byte EEPROM
32 kbyte FRAM
6GT2 800-4AC00
8 kbyte FRAM
6GT2 800-5BE00
32 kbyte FRAM
20 byte EEPROM
32 kbyte FRAM
6GT2 800-5BB00 6GT2 800-5AC00 6GT2 800-6BE00
32 kByte FRAM 32 kbyte FRAM 64 kbyte FRAM
13.56 MHz
Passive Tags
Operational Temperature Range Suitable for
-40°C to 140°C -40°C to 100°C -40°C to 85°C -40°C to 85°C -40°C to 85°C -40°C to 85°C --40°C to 220°C
Dimensions( L x W x D) mm Dynamic
Ø 27 x 4 Ø 30 x 8 48 x 25 x 15 50 x 50 x 20 85.8 x 54.1 x 2.5 75 x 75 x 41 Ø 114 x 83
Ingress Protection (IP) Rating Operation
IP67/IPX9K IP68/IPX9K IP67/IPX9K IP68 IP67 IP68 IP68
RF350R ANT 12
RS422

6GT2801-4BA10 NO
6GT2801-4BA10-0AX2 (Ex)
6GT2 398-1CC00 (ANT 12) *) **) Ø12 x 40

RF350R ANT 18
RS422
0-10/ 13 1-11/ 13 0-18/ 22
6GT2801-4BA10 NO
6GT2801-4BA10-0AX2 (Ex) (0-0.39/ 0.51) (0.04-0.43/ 0.51) (0.0-0.71/ 0.87)
6GT2 398-1CA00 (ANT 18) *) **)
Ø18 x 55
RF350R ANT 30
RS422
0-15/ 20 2-15/ 18 1-25/ 30 0-35/ 40 2-32/ 38
6GT2801-4BA10 NO
(0-0.59/ 0.79) (0.08-0.59/ 0.71) (0.04-0.98/ 1.1 8) (0-1.18/ 1.57) (0.08-1.26/ 1.5)
6GT2801-4BA10-0AX2 (Ex)
6GT2 398-1CD00 (ANT 30) *) Ø30 x 58
RF380R
RS422, RS232
2-45/ 60 5-45/ 48 2-80/ 105 2-100/ 125 2-120/ 150 5-100/ 135 5-125/ 160
6GT2801-3BA10
Integrated YES
(0.08-1.77/ 2.36) (0.2-1.77/ 1.89) (0.08-3.15/ 4.13) (0.08-3.94/ 4.92) (0.08-4.72/ 5.91) (0.20-3.94/ 5.31) (0.20-4.92/ 6.30)
6GT2801-3BA10-0AX2 (Ex)
160 x 96 x 41

Holder:
(short: 6GT2 090-0QA00)
20 mm spacer (long: 6GT2 090-0QA00-
(6GT2 190-0AA00) 0AX3)
Accessories Spacer Mounting cover Cover for holder:
(6GT2 690-0AK00) (6GT2 690-0AE00) (6GT2 090-0QB00)
Fixing pocket
(6GT2 190-0AB00) All Purpose
Support
(6GT2 590-0QA00)

*) antennas also available in stainless steel: ANT12 (6GT2398-1DC10), ANT18 (6GT2398-1DA10), ANT30 (6GT2398-1DD10)
**) antennas also available with 0.6 m antenna cable; ANT12 (6GT2398-1CC10), ANT18 (6GT2398-1CA10)

Operating Distance Range (mm) / Maximum Distance for Stationary Tag (mm)
Operating Distance Range (inch) / Maximum Distance for Stationary Tag (inch)

Edition: August 2020 SIMATIC Ident Configuration Guide 22


D165 D261 D100 D200 D400 D160 D460
RF300 Family Matrix Antennas
6GT2 600-1AB00-0AX0 6GT2 600-1AA01-0AX0 6GT2 600-0AD10 6GT2 600-1AD00 -0AX0 6GT2 600-4AD00 6GT2 600-0AB10 6GT2 600-4AB00
(ISO Tags) 112 byte EEPROM 256 byte EEPROM 112 byte EEPROM 256 byte EEPROM 2 kbyte FRAM 112 byte EEPROM 2 kbyte FRAM

13.56 MHz
Passive Tags
Operational Temperature Range -25°C to 85°C -25°C to 85°C -25°C to 80°C -20°C to 60°C -20°C to 60°C -40°C to 175°C -40°C to 100°C
Dimensions( L x W x D) mm 86 x 54 x 0.3 55 x 55 x 0.3 85,6 x 54 x 0.9 85.6 x 54 x 0.8 85.6 x 54 x 0.8 Ø 16 x 3 Ø 16 x 3
Ingress Protection (IP) Rating IP65 IP65 IP68 IP67 IP68/IPx9K IP67/IPx9K
IP67
RF310R
RS422
6GT2801-1BA10 2-90/ 102 2-74/ 83 2-93/ 105 2-80/ 90 2-104/ 115 1-39/ 44 1-32/ 38
Integrated
6GT2801-1BA10-0AX1 (90°plate) (0.08-3.54/ 4.02) (0.08-2.91/ 3.27) (0.08-3.66/ 4.1) (0.08-3.15/ 3.54) (0.08-4.09/ 4.53) (0.04-1.54/ 1.73) (0.08-1.26/ 1.50)
6GT2801-1BA10-0AX2 (Ex) 55 x 75 x 30
6GT2 801-1BA20-0AX1 (Scanmode)
RF340R
RS422 15-120/ 140 15-60/ 70 5-110/ 140 10-100/ 115 2-100/ 130 2-35/ 60 2-25/ 40
Integrated
6GT2801-2BA10 (0.59-4.72/ 5.51) (0.59-2.36/ 2.76) (0.20-4.33/ 5.51) (0.39-3.94/ 4.53) (0.08-3.93/ 5.12) (0.08-1.38/ 2.36) (0.08-0.98/ 1.57)
6GT2801-2BA10-0AX2 (Ex) 75 x 75 x 41

RF350R ANT 1
RS422 5-100/ 120 5-80/ 95 5-110/ 140 5-95/ 115 2-110/ 135 2-35/ 60 2-32/ 38
6GT2801-4BA10
6GT2801-4BA10-0AX2 (Ex) (0.20-3.94/ 4.72) (0.20-3.15/ 3.74) (0.20-4.33/ 5.51) (0.20-3.74/ 4.53) (0.08-4.33/ 5.31) (0.08-1.38/ 2.36) (0.08-1.26/ 1.50)
6GT2 398-1CB00 (ANT 1) 75 x 75 x 20

RF350R ANT 3
RS422 1-28/ 35 1-20/ 28
6GT2801-4BA10
6GT2801-4BA10-0AX2 (Ex) (0.04-1.10/ 1.38) (0.04-0.79/ 1.10)
6GT2 398-1CD40-0AX0 (ANT 3) 28 x 50 x 10

RF350R ANT 3S
RS422
6GT2801-4BA10
6GT2801-4BA10-0AX2 (Ex)
6GT2 398-1CD60-0AX0 (ANT 3S) 28 x 50 x 10
RF350R ANT 12
RS422 0-8/ 12 1-8/ 10
6GT2801-4BA10
6GT2801-4BA10-0AX2 (Ex) (0-0.31/ 0.47) (0.04-0.31/ 0.39)
6GT2 398-1CC00 (ANT 12) *) **) Ø12 x 40
RF350R ANT 18
RS422 1-18/ 20 1-12/ 16
6GT2801-4BA10
6GT2801-4BA10-0AX2 (Ex) (0.04-0.71/ 0.79) (0.04-0.47/ 0.63)
6GT2 398-1CA00 (ANT 18) *) **) Ø18 x 55

Holder Holder Holder


(6GT2 390-0AA00) (6GT2 390-0AA00) (6GT2 390-0AA00)
Spacer Spacer
Accessories 20 mm spacer 20 mm spacer 20 mm spacer (6GT2 690-0AG00) (6GT2 690-0AG00)
(6GT2 190-0AA00) (6GT2 190-0AA00) (6GT2 190-0AA00) Angle pattern body Angle pattern body
(6GT2690-0AN00) (6GT2690-0AN00)
Fixing pocket Fixing pocket Fixing pocket
(6GT2 190-0AB00) (6GT2 190-0AB00) (6GT2 190-0AB00)

Operating Distance Range (mm) / Maximum Distance for Stationary Tag (mm)
Operating Distance Range (inch) / Maximum Distance for Stationary Tag (inch)

Edition: August 2020 SIMATIC Ident Configuration Guide 23


D165 D261 D100 D200 D400 D160 D460
RF300 Family Matrix Antennas
6GT2 600-1AB00-0AX0 6GT2 600-1AA01-0AX0 6GT2 600-0AD10 6GT2 600-1AD00 -0AX0 6GT2 600-4AD00 6GT2 600-0AB10 6GT2 600-4AB00
(ISO Tags) 112 byte EEPROM 256 byte EEPROM 112 byte EEPROM 256 byte EEPROM 2 kbyte FRAM 112 byte EEPROM 2 kbyte FRAM

13.56 MHz
Passive Tags
Operational Temperature Range -25°C to 85°C -25°C to 85°C -25°C to 80°C -20°C to 60°C -20°C to 60°C -40°C to 175°C -40°C to 100°C
Dimensions( L x W x D) mm 86 x 54 x 0.3 55 x 55 x 0.3 85,6 x 54 x 0.9 85.6 x 54 x 0.8 85.6 x 54 x 0.8 Ø 16 x 3 Ø 16 x 3
Ingress Protection (IP) Rating IP65 IP65 IP68 IP67 IP68/IPx9K IP67/IPx9K
IP67

RF350R ANT 30
RS422 1-24/ 28 1-18/ 20
6GT2801-4BA10
6GT2801-4BA10-0AX2 (Ex) (0.04-0.94/ 1.10) (0.04-0.71/ 0.79)
6GT2 398-1CD00 (ANT 30) *) Ø30 x 58
RF380R
RS422, RS232
10-170/ 200 20-120/ 160 10-170/ 210 20-150/195 10-165/ 185 2-64/ 80 2-65/ 90
Integrated
6GT2801-3BA10 (0.39-6.69/ 7.87) (0.79-4.72/ 6.30) (0.39-6.69/ 8.27) (0.79-5.90/ 7.67) (0.39-4.50/ 7.28) (0.08-2.52/ 3.15) (0.08-2.56/ 3.54)
6GT2801-3BA10-0AX2 (Ex) 160 x 96 x 41

RF382R
RS422, RS232 35-50/ 65 35-50/ 60
Integrated
(1.38-1.97/ 2.56) (1.38-1.97/ 2.36)
160 x 96 x 41
6GT2801-3AB20-0AX0

Holder Holder Holder


(6GT2 390-0AA00) (6GT2 390-0AA00) (6GT2 390-0AA00)
Spacer Spacer
Accessories 20 mm spacer 20 mm spacer 20 mm spacer (6GT2 690-0AG00) (6GT2 690-0AG00)
(6GT2 190-0AA00) (6GT2 190-0AA00) (6GT2 190-0AA00) Angle pattern body Angle pattern body
(6GT2690-0AN00) (6GT2690-0AN00)
Fixing pocket Fixing pocket Fixing pocket
(6GT2 190-0AB00) (6GT2 190-0AB00) (6GT2 190-0AB00)

*) antennas also available in stainless steel: ANT12 (6GT2398-1DC10), ANT18 (6GT2398-1DA10), ANT30 (6GT2398-1DD10)
**) antennas also available with 0.6 m antenna cable; ANT12 (6GT2398-1CC10), ANT18 (6GT2398-1CA10)

Operating Distance Range (mm) / Maximum Distance for Stationary Tag (mm)
Operating Distance Range (inch) / Maximum Distance for Stationary Tag (inch)

Edition: August 2020 SIMATIC Ident Configuration Guide 24


D117 D127 D421 D422 D124 D324 D424
RF300 Family Matrix Antennas
6GT2 600-0AG00 6GT2 600-0AF00 6GT2 600-4AE00 6GT2 600-4AF00 6GT2 600-0AC10 6GT2 600-3AC00 6GT2 600-4AC00
112 byte EEPROM 2 kbyte FRAM 2 kbyte FRAM
(ISO Tags) 112 byte EEPROM 112 byte EEPROM 992 byte EEPROM 2 kbyte FRAM

13.56 MHz
Passive Tags
-40°C to 125°C -40°C to 125°C -40°C to 100°C -40°C to 100°C -40°C to 180°C -40°C to 140°C -40°C to 100°C
Operational Temperature Range Ø4 x 5.2
Dimensions( L x W x D) mm Ø 6 x 5.8 Ø10 x 4.5 Ø20 x 6 Ø 27 x 4 Ø 27 x 4 Ø 27 x 4
IP68 IPx9K IP68/ IPx9K IP67/ IPx9K IP68 IP68/ IPx9K IP67 IP67/ IPx9K
Ingress Protection (IP) Rating

RF310R
RS422
6GT2801-1BA10 2-64/ 72 2-64/ 72 1-68/ 75
Integrated
6GT2801-1BA10-0AX1 (90°plate) (0.08-2.52/ 2.83) (0.08-2.52/ 2.83) (0.04-2.68/ 2.95)
6GT2801-1BA10-0AX2 (Ex) 55 x 75 x 30
6GT2 801-1BA20-0AX1 (Scanmode)
RF340R
RS422 2-60/ 75 2-55/ 70 2-55/ 70
Integrated
6GT2801-2BA10 (0.08-2.36/ 2.95) (0.08-2.17/ 2.76) (0.08-2.17/ 2.76)
6GT2801-2BA10-0AX2 (Ex) 75 x 75 x 41

RF350R ANT 1
RS422 2-65/ 85 2-66/ 78 2-75/ 88
6GT2801-4BA10
6GT2801-4BA10-0AX2 (Ex) (0.08-2.56/ 3.35) (0.08-2.60/ 3.07) (0.08-2.95/ 3.46)
6GT2 398-1CB00 (ANT 1) 75 x 75 x 20

RF350R ANT 3
RS422
1-11/18 1-35/ 42 1-22/ 32 1-40/ 48
6GT2801-4BA10
(0.04-0.43/ 0.71) (0.04-1.38/ 1.65) (0-0.04/ 1.26) (0.04-1.57/ 1.89)
6GT2801-4BA10-0AX2 (Ex)
6GT2 398-1CD40-0AX0 (ANT 3) 28 x 50 x 10

RF350R ANT 3S
RS422
0-2/ 3 0-2/ 3 0-4/ 5
6GT2801-4BA10
(0.0-0.08/ 0.12) (0-0.08/ 0.12) (0-0.16/ 0.20)
6GT2801-4BA10-0AX2 (Ex)
6GT2 398-1CD60-0AX0 (ANT 3S) 28 x 50 x 10
RF350R ANT 12
RS422 0-2/ 3 0-3/ 4 0-3/ 5
6GT2801-4BA10
(0.0-0.08/ 0.12) (0-0.12/ 0.16) (0-0.12/ 0.20)
6GT2801-4BA10-0AX2 (Ex)
6GT2 398-1CC00 (ANT 12) *) **) Ø12 x 40

RF350R ANT 18
RS422 1-5/ 6 1-5/ 6 0-6/ 8 1-10/ 13 2-24/ 28 1-22/ 28 1-27/ 35
6GT2801-4BA10
(0.04-0.20/ 0.24) (0.04-0.20/ 0.24) (0-0.24/ 0.31) (0.04-0.39/ 0.51) (0.08-0.94/ 1.10) (0.04-0.87/ 1.1) (0.04-1.06/ 1.38)
6GT2801-4BA10-0AX2 (Ex)
6GT2 398-1CA00 (ANT 18) *) **) Ø18 x 55

Spacer Spacer Spacer


Accessories (6GT2 690-0AK00) (6GT2 690-0AK00) (6GT2 690-0AK00)

Operating Distance Range (mm) / Maximum Distance for Stationary Tag (mm)
Operating Distance Range (inch) / Maximum Distance for Stationary Tag (inch)

Edition: August 2020 SIMATIC Ident Configuration Guide 25


D117 D127 D421 D422 D124 D324 D424
RF300 Family Matrix Antennas
6GT2 600-0AG00 6GT2 600-0AF00 6GT2 600-4AE00 6GT2 600-4AF00 6GT2 600-0AC10 6GT2 600-3AC00 6GT2 600-4AC00
112 byte EEPROM 2 kbyte FRAM 2 kbyte FRAM
(ISO Tags) 112 byte EEPROM 112 byte EEPROM 992 byte EEPROM 2 kbyte FRAM

13.56 MHz
Passive Tags
-40°C to 125°C -40°C to 125°C -40°C to 100°C -40°C to 100°C -40°C to 180°C -40°C to 140°C -40°C to 100°C
Operational Temperature Range Ø4 x 5.2
Dimensions( L x W x D) mm Ø 6 x 5.8 Ø10 x 4.5 Ø20 x 6 Ø 27 x 4 Ø 27 x 4 Ø 27 x 4
IP68 IPx9K IP68/ IPx9K IP67/ IPx9K IP68 IP68/ IPx9K IP67 IP67/ IPx9K
Ingress Protection (IP) Rating

RF350R ANT 30
RS422 0-14/ 16 1-35/ 40 1-35/ 40 0-45/ 50
6GT2801-4BA10
6GT2801-4BA10-0AX2 (Ex) (0-0.55/ 0.63) (0.04-1.38/ 1.57) (0.04-1.38/ 1.57) (0-1.77/ 1.97)
6GT2 398-1CD00 (ANT 30) *) Ø30 x 58
RF380R
RS422, RS232
1-120/ 140 2-96/ 120 2-120/ 140
Integrated
6GT2801-3BA10 (0.04-4.72/ 5.51) (0.08-3.78/ 4.72) (0.08-4.72/ 5.51)
6GT2801-3BA10-0AX2 (Ex) 160 x 96 x 41

RF382R
RS422, RS232 40-65/ 75 40-65/ 75 40-65/ 75
Integrated
160 x 96 x 41 (1.57-2.56/ 2.95) (1.57-2.56/ 2.95) (1.57-2.56/ 2.95)
6GT2801-3AB20-0AX0

Spacer Spacer Spacer


Accessories (6GT2 690-0AK00) (6GT2 690-0AK00) (6GT2 690-0AK00)

*) antennas also available in stainless steel: ANT12 (6GT2398-1DC10), ANT18 (6GT2398-1DA10), ANT30 (6GT2398-1DD10)
**) antennas also available with 0.6 m antenna cable; ANT12 (6GT2398-1CC10), ANT18 (6GT2398-1CA10)

Operating Distance Range (mm) / Maximum Distance for Stationary Tag (mm)
Operating Distance Range (inch) / Maximum Distance for Stationary Tag (inch)

Edition: August 2020 SIMATIC Ident Configuration Guide 26


D126 D426 D423 D425 D428 D139 D339
RF300 Family Matrix Antennas
6GT2 600-0AE00 6GT2 600-4AH00 6GT2 600-4AA00 6GT2 600-4AG00 6GT2 600-4AK00-0AX0 6GT2 600-0AA10 6GT2600-3AA10
2 kbyte FRAM 2 kbyte FRAM 2 kbyte FRAM 112 byte EEPROM
(ISO Tags) 112 byte EEPROM 2 kbyte FRAM 992 byte EEPROM

13.56 MHz
Passive Tags
-40°C to 100°C -40°C to 100°C -40°C to 100°C -40°C to 125°C -40°C to 125°C -40°C to 220°C -40°C to 220°C
Operational Temperature Range
Ø 50 x 3.6 Ø 50 x 3.6 Ø 30 x 8 Ø 24 x 10 Ø 24 x 20 Ø 85 x 15 Ø 85 x 15
Dimensions( L x W x D) mm
Ingress Protection (IP) Rating IP68 IP68 IP68/ IPx9K IP68/ IPx9K IP68/ IPx9K IP68/IPx9K IP68/IPx9K
RF310R
RS422
6GT2801-1BA10 2-65/ 73 5-75/ 90 2-35/ 40 1-22/ 25 1-40/ 45 5-96/ 109 5-74/ 84
Integrated
6GT2801-1BA10-0AX1 (90°plate) (0.08-2.56/ 2.87) (0.2-2.95/ 3.54) (0.08-1.37/ 1.57) (0.04-0.87/ 0.98) (0.08-1.57/ 1.77) (0.20-3.78/ 4.29) (0.20-2.91/ 3.31)
6GT2801-1BA10-0AX2 (Ex) 55 x 75 x 30
6GT2 801-1BA20-0AX1 (Scanmode)
RF340R
RS422 2-85/ 110 0-80/ 100 5-40/ 48 2-20/ 30 2-40/ 50 5-80/ 110 5-75/ 85
Integrated
6GT2801-2BA10 (0.08-3.34/ 4.33) (0.0-3.15/ 3.94) (0.2-1.57/ 1.89) (0.08-0.79/ 1.18) (0.08-1.57/ 1.97) (0.20-3.15/ 4.33) (0.20-2.95/ 3.35)
6GT2801-2BA10-0AX2 (Ex) 75 x 75 x 41

RF350R ANT 1
RS422 2-90/ 120 2-85/ 95 2-40/ 50 2-23/ 32 2-40/ 50 5-85/ 115 5-90/ 105
6GT2801-4BA10
6GT2801-4BA10-0AX2 (Ex) (0.08-3.54/ 4.72) (0.08-3.35/ 3.74) (0.08-1.57/ 1.97) (0.08-0.91/ 1.26) (0.08-1.57/ 1.97) (0.20-3.35/ 4.53) (0.20-3.54/ 4.13)
6GT2 398-1CB00 (ANT 1) 75 x 75 x 20

RF350R ANT 3
RS422 5-20/ 30 2-18/ 22 2-28/ 30
6GT2801-4BA10
6GT2801-4BA10-0AX2 (Ex) (0.2-0.79/ 1.18) (0.08-0.71/ 0.87) (0.08-1.10/ 1.18)
6GT2 398-1CD40-0AX0 (ANT 3) 28 x 50 x 10

RF350R ANT 3S
RS422
6GT2801-4BA10
6GT2801-4BA10-0AX2 (Ex)
6GT2 398-1CD60-0AX0 (ANT 3S) 28 x 50 x 10

RF350R ANT 12
RS422 1-10/ 17
6GT2801-4BA10
6GT2801-4BA10-0AX2 (Ex) (0.04-0.39/ 0.67)
6GT2 398-1CC00 (ANT 12) *) **) Ø12 x 40

RF350R ANT 18
RS422 1-10/ 14 1-15/ 20
6GT2801-4BA10
6GT2801-4BA10-0AX2 (Ex) (0.04-0.39/ 0.55) (0.04-0.59/ 0.79)
6GT2 398-1CA00 (ANT 18) *) **) Ø18 x 55

Spacer
(6GT2 690-0AA00)
Spacer Spacer Mounting cover
Accessories (6GT2 690-0AL00) (6GT2 690-0AL00) (6GT2 690-0AE00) Mount for quick tag exchange
(6GT2 690-0AH00 - long)
(6GT2 690-0AH10 – short)

Operating Distance Range (mm) / Maximum Distance for Stationary Tag (mm)
Operating Distance Range (inch) / Maximum Distance for Stationary Tag (inch)

Edition: August 2020 SIMATIC Ident Configuration Guide 27


D126 D426 D423 D425 D428 D139 D339
RF300 Family Matrix Antennas
6GT2 600-0AE00 6GT2 600-4AH00 6GT2 600-4AA00 6GT2 600-4AG00 6GT2 600-4AK00-0AX0 6GT2 600-0AA10 6GT2600-3AA10
2 kbyte FRAM 2 kbyte FRAM 2 kbyte FRAM 112 byte EEPROM
(ISO Tags) 112 byte EEPROM 2 kbyte FRAM 992 byte EEPROM

13.56 MHz
Passive Tags
-40°C to 100°C -40°C to 100°C -40°C to 100°C -40°C to 125°C -40°C to 125°C -40°C to 220°C -40°C to 220°C
Operational Temperature Range
Ø 50 x 3.6 Ø 50 x 3.6 Ø 30 x 8 Ø 24 x 10 Ø 24 x 20 Ø 85 x 15 Ø 85 x 15
Dimensions( L x W x D) mm
Ingress Protection (IP) Rating IP68 IP68 IP68/ IPx9K IP68/ IPx9K IP68/ IPx9K IP68/IPx9K IP68/IPx9K

RF350R ANT 30
RS422 1-42/ 50 0-45/ 48 1-38/ 40 1-15/ 20 1-25/ 28
6GT2801-4BA10
(0-1.65/ 1.97) (0-1.77/ 1.89) (0.04-1.50/ 1.57) (0.04-0.59/ 0.79) (0.04-0.98/ 1.10)
6GT2801-4BA10-0AX2 (Ex)
6GT2 398-1CD00 (ANT 30) *) Ø30 x 58
RF380R
RS422, RS232
2-145/ 190 2-155/ 195 5-75/ 90 2-35/ 50 2-70/ 95 5-160/ 200 5-160/ 180
Integrated
6GT2801-3BA10 (0.08-5.71/ 7.48) (0.0-6.1/ 7.68) (0.2-2.95/ 3.54) (0.08-1.38/ 1.97) (0.08-2.76/ 3.74) (0.20-6.30/ 7.87) (0.20-6.30/ 7.09)
6GT2801-3BA10-0AX2 (Ex) 160 x 96 x 41

RF382R
RS422, RS232 Integrated
160 x 96 x 41
6GT2801-3AB20-0AX0

Spacer
(6GT2 690-0AA00)
Spacer Spacer Mounting cover
Accessories (6GT2 690-0AL00) (6GT2 690-0AL00) (6GT2 690-0AE00) Mount for quick tag exchange
(6GT2 690-0AH00 - long)
(6GT2 690-0AH10 – short)

*) antennas also available in stainless steel: ANT12 (6GT2398-1DC10), ANT18 (6GT2398-1DA10), ANT30 (6GT2398-1DD10)
**) antennas also available with 0.6 m antenna cable; ANT12 (6GT2398-1CC10), ANT18 (6GT2398-1CA10)

Operating Distance Range (mm) / Maximum Distance for Stationary Tag (mm)
Operating Distance Range (inch) / Maximum Distance for Stationary Tag (inch)

Edition: August 2020 SIMATIC Ident Configuration Guide 28


D521 D522 D524 D525 D526 D528 D560
RF300 Family Matrix Antennas
6GT2 600-5AE00 6GT2 600-5AF00 6GT2 600-5AC00 6GT2 600-5AG00 6GT2 600-5AH00 6GT2 600-5AK00 6GT2 600-5AB00
8 kbyte FRAM
(8 KB ISO Tags) 8 kByte FRAM 8 kByte FRAM 8 kByte FRAM 8 kByte FRAM 8 kByte FRAM 8 kByte FRAM

13.56 MHz
Passive Tags
Operational Temperature Range -40°C to 10°C -40°C to 100°C -40°C to 100°C -40°C to 125°C -40°C to 100°C -40°C to 125°C -40°C to 90°C
Dimensions( L x W x D) mm Ø 10 x 4.5 Ø 20 x 6 Ø 27 x 4 Ø 24 x 10 Ø 50 x 3.6 Ø 24 x 20 Ø 16 x 3
Ingress Protection (IP) Rating IP67/IPx9K IP68 IP67 / IPx9k IP68 / IPx9k IP68 IP68/IPx9K IP68/IPx9K

RF310R
RS422 1…70/78 1…22/25 5…80/90 1…43/48 1…32/38
6GT2801-1BA10 Integrated
6GT2801-1BA10-0AX1 (90°plate) (0.04-2.76/ 3.07) (0.04-0.87/ 0.98) (0.2-3.14/ 3.54) (0.04-1.69/ 1.89) (0.04-1.26/ 1.5)
55 x 75 x 30
6GT2801-1BA10-0AX2 (Ex)
RF340R
RS422 2…55/70 2…20/30 0…80/100 2…40/50 2…25/40
Integrated
6GT2801-2BA10 75 x 75 x 41 (0.08-2.16/ 2.76) (0.08-0.79/ 1.18) (0-3.15/ 3.94) (0.08-1.57/ 1.97) (0.08-0.98/ 1.57)
6GT2801-2BA10-0AX2 (Ex)
RF350R ANT 1
RS422 2…65/85 2…25/35 0…85/105 2…35/50 2…32/38
6GT2801-4BA10
6GT2801-4BA10-0AX2 (Ex) (0.08-2.56/ 3.35) (0.08-0.98/ 1.38) (0-3.35/ 4.13) (0.08-1.38/ 1.97) (0.08-1.26/ 1.5)
6GT2 398-1CB00 (ANT 1) 75 x 75 x 20
RF350R ANT 3
RS422 1…19/22 5…52/56 2…21/24 2…24/26 1…20/28
6GT2801-4BA10
6GT2801-4BA10-0AX2 (Ex) (0.04-0.75/ 0.87) (0.2-2.05/ 2.20) (0.08-0.83/ 0.94) (0.08-0.94/ 1.02) (0.04-0.79/ 1.1)
6GT2 398-1CD40-0AX0 (ANT 3) 28 x 50 x 10
RF350R ANT 3S
RS422 0…3/4
6GT2801-4BA10
6GT2801-4BA10-0AX2 (Ex) (0-0.12/ 0.16)
6GT2 398-1CD60-0AX0 (ANT 3S) 28 x 50 x 10
RF350R ANT 12
RS422 0…4/5 1…16/17 1…8/10
6GT2801-4BA10
6GT2801-4BA10-0AX2 (Ex) (0-0.16/ 0.2) (0.04-0.63/ 0.67) (0.04-0.31/ 0.39)
6GT2 398-1CC00 (ANT 12) *) **) Ø12 x 40
RF350R ANT 18
RS422 0…6/8 1…10/13 1…27/35 1…10/14 1…15/20 1…12/16
6GT2801-4BA10
6GT2801-4BA10-0AX2 (Ex) (0-0.24/ 0.31) (0.04-0.39/ 0.51) (0.04-1.06/ 1.38) (0.04-0.39/ 0.55) (0.04-0.59/ 0.79) (0.04-0.47/ 0.63)
Ø18 x 55
6GT2 398-1CA00 (ANT 18) *) **)

Spacer
Spacer Spacer (6GT2 690-0AG00)
Accessories
(6GT2 690-0AK00) (6GT2 690-0AL00) Angle pattern body
(6GT2690-0AN00)

*) antennas also available in stainless steel: ANT12 (6GT2398-1DC10), ANT18 (6GT2398-1DA10), ANT30 (6GT2398-1DD10)
**) antennas also available with 60 cm antenna cable; ANT12 (6GT2398-1CC10), ANT18 (6GT2398-1CA10)

Operating Distance Range (mm) / Maximum Distance for Stationary Tag (mm)
Operating Distance Range (inch) / Maximum Distance for Stationary Tag (inch)

Edition: August 2020 SIMATIC Ident Configuration Guide 29


D521 D522 D524 D525 D526 D528 D560
RF300 Family Matrix Antennas
6GT2 600-5AE00 6GT2 600-5AF00 6GT2 600-5AC00 6GT2 600-5AG00 6GT2 600-5AH00 6GT2 600-5AK00 6GT2 600-5AB00
8 kbyte FRAM
(8 KB ISO Tags) 8 kByte FRAM 8 kByte FRAM 8 kByte FRAM 8 kByte FRAM 8 kByte FRAM 8 kByte FRAM

13.56 MHz
Passive Tags
Operational Temperature Range -40°C to 10°C -40°C to 100°C -40°C to 100°C -40°C to 125°C -40°C to 100°C -40°C to 125°C -40°C to 90°C
Dimensions( L x W x D) mm Ø 10 x 4.5 Ø 20 x 6 Ø 27 x 4 Ø 24 x 10 Ø 50 x 3.6 Ø 24 x 20 Ø 16 x 3
Ingress Protection (IP) Rating IP67/IPx9K IP68 IP67 / IPx9k IP68 / IPx9k IP68 IP68/IPx9K IP68/IPx9K

RF350R ANT 30
RS422 1-19/ 22 0-45/ 50 1-15/ 20 0-45/ 48 1-25/ 28 1-18/ 20
6GT2801-4BA10
(0.04-0.75/ 0.87) (0-1.77/ 1.97) (0.04-0.59/ 0.79) (0-1.77/ 1.89) (0.04-0.98/ 1.10) (0.04-0.71/ 0.79)
6GT2801-4BA10-0AX2 (Ex) Ø30 x 58
6GT2 398-1CD00 (ANT 30) *)
RF380R
RS422, RS232
Integrated 2-120/ 140 2-35/ 50 2-155/ 195 2-70/ 95 2-65/ 90
6GT2801-3BA10 (0.08-4.72/ 5.51) (0.08-1.38/ 1.97) (0.08-6.10/ 7.68) (0.08-2.76/ 3.74) (0.08-2.56/ 3.54)
6GT2801-3BA10-0AX2 (Ex)

Spacer
Spacer Spacer (6GT2 690-0AG00)
Accessories
(6GT2 690-0AK00) (6GT2 690-0AL00) Angle pattern body
(6GT2690-0AN00)

*) antennas also available in stainless steel: ANT12 (6GT2398-1DC10), ANT18 (6GT2398-1DA10), ANT30 (6GT2398-1DD10)
**) antennas also available with 0.6 m antenna cable; ANT12 (6GT2398-1CC10), ANT18 (6GT2398-1CA10)

Operating Distance Range (mm) / Maximum Distance for Stationary Tag (mm)
Operating Distance Range (inch) / Maximum Distance for Stationary Tag (inch)

Edition: August 2020 SIMATIC Ident Configuration Guide 30


E600 E611 E623 E624
RF300 Family Matrix Antennas
6GT2 300-0AA00 6GT2 300-0BB00 6GT2 300-0CD00 6GT2 300-0CE00
(MOBY E compatibility) 752 byte EEPROM 752 byte EEPROM 752 byte EEPROM 752 byte EEPROM

13.56 MHz
Passive Tags
-25°C to 60°C -40°C to 85°C -40°C to 100°C -40°C to 150°C
Operational Temperature Range
Dimensions( L x W x D) mm 86 x 54 x 0.76 86 x 54 x 2.5 Ø10 x 4.5 Ø 27 x 4
Ingress Protection (IP) Rating IP68 IP67 IP67/ IPx9K IP67/ IPx9K

RF310R
RS422 2-30/ 43 2-40/ 60 2-35/ 36
6GT2801-1BA10 Integrated
(0.08-1.18/ 1.69) (0.08-1.57/ 2.36) (0.08-1.37/ 1.42)
6GT2801-1BA10-0AX1 (90°plate)
6GT2801-1BA10-0AX2 (Ex) 55 x 75 x 30

RF340R
RS422 5-50/ 65 10-50/ 65 2-35/ 45
Integrated
(0.2-1.97/ 2.56) (0.39-1.97/ 2.56) (0.08-1.37/ 1.77)
6GT2801-2BA10
75 x 75 x 41
6GT2801-2BA10-0AX2 (Ex)
RF350R ANT 1
RS422 10-50/ 60 20-50/ 65 2-35/ 45
6GT2801-4BA10
(0.39-1.97/ 2.36) (0.79-1.97/ 2.56) (0.08-1.37/ 1.77)
6GT2801-4BA10-0AX2 (Ex)
6GT2 398-1CB00 (ANT 1) 75 x 75 x 20
RF350R ANT 3
RS422
6GT2801-4BA10
1-15/ 16
(0.04-0.59/ 0.63)
6GT2801-4BA10-0AX2 (Ex)
6GT2 398-1CD40-0AX0 (ANT 3) 28 x 50 x 10
RF350R ANT 3S
RS422
6GT2801-4BA10
6GT2801-4BA10-0AX2 (Ex)
6GT2 398-1CD60-0AX0 (ANT 3S) 28 x 50 x 10
RF350R ANT 12
RS422 0-4/ 5
6GT2801-4BA10
(0-0.16/ 0.20)
6GT2801-4BA10-0AX2 (Ex)
6GT2 398-1CC00 (ANT 12) *) **) Ø12 x 40
RF350R ANT 18
RS422 0-6/ 8 2-15/ 20
6GT2801-4BA10
(0-0.24/ 0.31) (0.08-0.59/ 0.79)
6GT2801-4BA10-0AX2 (Ex)
6GT2 398-1CA00 (ANT 18) *) **) Ø18 x 55
Holder Holder
(6GT2 390-0AA00) (6GT2 390-0AA00)
20 mm spacer 20 mm spacer Spacer
Accessories (6GT2 190-0AA00) (6GT2 190-0AA00) (6GT2 690-0AK00)
Fixing pocket Fixing pocket
(6GT2 190-0AB00) (6GT2 190-0AB00)

*) antennas also available in stainless steel: ANT12 (6GT2398-1DC10), ANT18 (6GT2398-1DA10), ANT30 (6GT2398-1DD10)
**) antennas also available with 60 cm antenna cable; ANT12 (6GT2398-1CC10), ANT18 (6GT2398-1CA10)

Operating Distance Range (mm) / Maximum Distance for Stationary Tag (mm)
Operating Distance Range (inch) / Maximum Distance for Stationary Tag (inch)

Edition: August 2020 SIMATIC Ident Configuration Guide 31


E600 E611 E623 E624
RF300 Family Matrix Antennas
6GT2 300-0AA00 6GT2 300-0BB00 6GT2 300-0CD00 6GT2 300-0CE00
(MOBY E compatibility) 752 byte EEPROM 752 byte EEPROM 752 byte EEPROM 752 byte EEPROM

13.56 MHz
Passive Tags
-25°C to 60°C -40°C to 85°C -40°C to 100°C -40°C to 150°C
Operational Temperature Range
Dimensions( L x W x D) mm 86 x 54 x 0.76 86 x 54 x 2.5 Ø10 x 4.5 Ø 27 x 4
Ingress Protection (IP) Rating IP68 IP67 IP67/ IPx9K IP67/ IPx9K

RF350R ANT 30
RS422 1-20/ 24
6GT2801-4BA10
(0.04-0.79/ 0.94)
6GT2801-4BA10-0AX2 (Ex) Ø30 x 58
6GT2 398-1CD00 (ANT 30) *)
RF380R
RS422, RS232
Integrated 10-80/ 95 10-115/ 135 5-50/ 60
6GT2801-3BA10 (0.39-3.15/ 3.74) (0.39-4.53/ 5.31) (0.20-1.97/ 2.36)
6GT2801-3BA10-0AX2 (Ex)

Holder Holder
(6GT2 390-0AA00) (6GT2 390-0AA00)
20 mm spacer 20 mm spacer Spacer
Accessories (6GT2 190-0AA00) (6GT2 190-0AA00) (6GT2 690-0AK00)
Fixing pocket Fixing pocket
(6GT2 190-0AB00) (6GT2 190-0AB00)

*) antennas also available in stainless steel: ANT12 (6GT2398-1DC10), ANT18 (6GT2398-1DA10), ANT30 (6GT2398-1DD10)
**) antennas also available with 0.6 m antenna cable; ANT12 (6GT2398-1CC10), ANT18 (6GT2398-1CA10)

Operating Distance Range (mm) / Maximum Distance for Stationary Tag (mm)
Operating Distance Range (inch) / Maximum Distance for Stationary Tag (inch)

Edition: August 2020 SIMATIC Ident Configuration Guide 32


RF300 System Interfaces

PROFINET & OPC UA & Ethernet/IP & TCP/IP Tags


Reader
powered through connection cable
Communication Modules A maximum of RF320T
1 reader at RF185C, (6GT2 800-1CA00)
2 readers at RF186C/CI,
4 readers at RF188C/CI

+ +
of RF3x0R may be connected RF330T
(6GT2 800-5BA00)
RF185C RF186C RF188C 2 m = 6GT2 891-4FH20 5 m = 6GT2 891-4FH50
(6GT2 002-0JE10) (6GT2 002-0JE20) (6GT2 002-0JE40) 10 m = 6GT2 891-4FN10 20 m = 6GT2 891-4FN20
50 m = 6GT2 891-4FN50*

Reader connector 90° angled: RF310R RS422 RF340T


2 m = 6GT2 891-4JH20 5 m = 6GT2 891-4JH50 6GT2 801-1BA10 (8 kb: 6GT2 800-4BB00)
Additional IOs 10 m = 6GT2 891-4JN10 6GT2801-1BA10-0AX1 (90°plate) (32 kb: 6GT2 800-5BB00)
6GT2801-1BA10-0AX2 (Ex)

+ RF18xCI to sensor
+ Types of IO-Link
IO module
IO-extension module
RF350T
(6GT2 800-5BD00)

RF186CI RF188CI 6ES7 14….. (up to 8xDI + 8xDO)


Sensor cable from
(6GT2 002-0JE50) (6GT2 002-0JE60)
0.5 to 15 m available RF360T
(e.g. 2 m = 6XV1801-2CH20) See page 76 for detailed information (8 kb: 6GT2 800-4AC00)
RF340R (32 kb: 6GT2 800-5AC00)
6GT2 801-2BA10
6GT2801-2BA10-0AX2 (Ex)

Or one
RF370T
Standard sensor (32 kb: 6GT2 800-5BE00)
ANT 1 (64 kb: 6GT2 800-6BE00)
Or one (6GT2 398-1CB00)
Actor ANT 3
(6GT2 398-1CD40-0AX0)
ANT 3S RF380T
(6GT2 398-1CD60-0AX0) (6GT2 800-5DA00)

ANT 12 ISO TAGs


(6GT2 398-1CC00) D100 6GT2 600-0AD10
(6GT2398-1DC10 steel) D200 6GT2 600-1AD00-0AX0
ANT 18 D400 6GT2 600-4AD00
RF350R (6GT2 398-1CA00) D117 6GT2 600-0AG00
6GT2 801 (6GT2398-1DA10 steel) D421 6GT2 600-4AE00
-4BA10, D422 6GT2 600-4AF00
/-4BA10-0AX2 ANT 30 D423 6GT2 600-4AA00
(Ex) (6GT2 398-1CD00)
D124 6GT2 600-0AC10
(6GT2398-1DD10 steel)
D324 6GT2 600-3AC00
D424 6GT2 600-4AC00
D425 6GT2 600-4AG00
D126 6GT2 600-0AE00
D426 6GT2 600-4AH00
D127 6GT2 600-0AF00
D428 6GT2 600-4AK00-0AX0
D139 6GT2 600-0AA10
D339 6GT2 600-3AA10
RF380R D160 6GT2 600-0AB10
6GT2 801-3BA10 D460 6GT2 600-4AB00
6GT2801-3BA10-0AX2 (Ex) D560 6GT2600-5AB00
D261 6GT2 600-1AA01-0AX0
D165 6GT2 600-1AB00-0AX0
Edition: August 2020 SIMATIC Ident Configuration Guide 33
RF300 System Interfaces

SIMATIC PLC Tags


Reader
+ +
A maximum of 1 readers may be connected powered through connection cable
S7-1200 RF120C to RF3x0R RF320T
(6GT2 800-1CA00)
2 m = 6GT2 091-4LH20 5 m = 6GT2 091-4LH50
10m = 6GT2 091-4LN10
And extension cables:
RF120C 2 m = 6GT2 891-4FH20 5 m = 6GT2 891-4FH50 RF330T
6GT2 002-0LA00 10 m = 6GT2 891-4FN10 20 m = 6GT2 891-4FN20 (6GT2 800-5BA00)
50 m = 6GT2 891-4FN50
Up to 3 x 120C modules 2 m = 6GT2 891-4JH20 Reader connector 90° angled
per S7-1200 rack 5 m = 6GT2 891-4JH50 Reader connector 90° angled
10 m = 6GT2 891-4JN10 Reader connector 90° angled
RF310R RS422 RF340T
6GT2 801-1BA10
SIMATIC PLC
(8 kb: 6GT2 800-4BB00)
6GT2801-1BA10-0AX1 (90°plate) (32 kb: 6GT2 800-5BB00)
6GT2801-1BA10-0AX2 (Ex)

+ + +
A maximum of 2 Readers may be connected
S7-300 Rack or
ASM 475 to RF3x0R
RF350T
S7-400 via ET 200M 2 m = 6GT2 891-4EH20 5 m = 6GT2 891-4EH50 (6GT2 800-5BD00)

(DP-V1/PN-IO) ASM 475 + Front Connector


And Extension Cables:
2 m = 6GT2 891-4FH20 5 m = 6GT2 891-4FH50
10 m = 6GT2 891-4FN10 20 m = 6GT2 891-4FN20
(6GT2 002-0GA10) + (6ES7 392-1AJ00-0AA0) 50 m = 6GT2 891-4FN50
RF360T
(8 kb: 6GT2 800-4AC00)
2 m = 6GT2 891-4JH20 Reader connector 90° angled
Accessories:
5 m = 6GT2 891-4JH50 Reader connector 90° angled RF340R (32 kb: 6GT2 800-5AC00)
Connecting element (6ES7 390-5AA00-0AA0) 6GT2 801-2BA10
10 m = 6GT2 891-4JN10 Reader connector 90° angled
Terminal element (6ES7 390-5BA00-0AA0) 6GT2801-2BA10-0AX2 (Ex)

RF370T
ET 200pro ET 200pro PROFIBUS DP-V1
Interface Modul
ANT 1
(6GT2 398-1CB00)
(32 kb: 6GT2 800-5BE00)
(64 kb: 6GT2 800-6BE00)

via PROFIBUS ANT 3

+ + +
ET 200pro PROFINET (6GT2 398-1CD40-0AX0)
A maximum of 2 readers may be connected
or PROFINET Interface Modul
RF170C to RF3x0R ANT 3S RF380T
(6GT2 800-5DA00)
or S7 PLC ET 200pro PROFINET 2 m = 6GT2 891-4FH20 5 m = 6GT2 891-4FH50
(6GT2 398-1CD60-0AX0)
ANT 12 ISO TAGs
CPU module RF170C 10 m = 6GT2 891-4FN10 20 m = 6GT2 891-4FN20
(6GT2 398-1CC00)
50 m = 6GT2 891-4FN50 D100 6GT2 600-0AD10
Communication Module (6GT2398-1DC10 steel)
Up to 9 x 170C (6GT2002-0HD01) D200 6GT2 600-1AD00-0AX0
Reader connector 90° angled ANT 18 D400 6GT2 600-4AD00
modules per Connection Block
(6GT2002-1HD01) 2 m = 6GT2 891-4JH20 5 m = 6GT2 891-4JH50 RF350R (6GT2 398-1CA00) D117 6GT2 600-0AG00
ET 200pro rack 10 m = 6GT2 891-4JN10 6GT2 801 (6GT2398-1DA10 steel) D421 6GT2 600-4AE00
-4BA10, D422 6GT2 600-4AF00
/-4BA10-0AX2 ANT 30 D423 6GT2 600-4AA00
PROFIBUS (Ex) (6GT2 398-1CD00)
(6GT2398-1DD10 steel)
D124 6GT2 600-0AC10
D324 6GT2 600-3AC00
A maximum of 2 readers may be connected
+ +
D424 6GT2 600-4AC00
D425 6GT2 600-4AG00
RF166C to RF2x0R D126 6GT2 600-0AE00
2 m = 6GT2 891-4FH20 5 m = 6GT2 891-4FH50 D426 6GT2 600-4AH00
10 m = 6GT2 891-4FN10 20 m = 6GT2 891-4FN20 D127 6GT2 600-0AF00
50 m = 6GT2 891-4FN50* D428 6GT2 600-4AK00-0AX0
D139 6GT2 600-0AA10
Reader connector 90° angled D339 6GT2 600-3AA10
RF166C (DP-V1) 2 m = 6GT2 891-4JH20 5 m = 6GT2 891-4JH50 RF380R D160 6GT2 600-0AB10
Communication Module 10 m = 6GT2 891-4JN10 6GT2 801-3BA10 D460 6GT2 600-4AB00
(6GT2 002-0EE20) 6GT2801-3BA10-0AX2 (Ex) D560 6GT2600-5AB00
D261 6GT2 600-1AA01-0AX0
D165 6GT2 600-1AB00-0AX0
Edition: August 2020 SIMATIC Ident Configuration Guide 34
RF300 System Interfaces
RS232/RS422 Reader Tags
with external power supply
RS232 RF320T
RS232 RS422 (6GT2 800-1CA00)

+ +
1 Reader per COM port may be connected

Open Wire to RF310R


RS422 24VDC OUT Scanmode RF330T
RF310R Scanmode (6GT2 800-5BA00)
No Driver needed 2 m = 6GT2 891-4EH20
(6GT2 801-1BA20-0AX1)
5 m = 6GT2 891-4EH50
Scanmode; Read only 24VDC IN Interface Converter
(ie. TRP-C06 Trycom IP)
RF340T
(8 kb: 6GT2 800-4BB00)

RS232 Reader (32 kb: 6GT2 800-5BB00)

with external power supply at Y-cable

+
1 Reader per COM port may be connected RF350T

+
(6GT2 800-5BD00)
Wide-Range power supply + 5 m cable RS 232 cable for RF382R
6GT2 898-0ACxx + 6GT2 491-1HH50 5 m = 6GT2 891-4KH50
Extension cables: 5 m = 6GT2 891-4FH50
10 m = 6GT2 891-4FN10 RF382R RF360T
No Driver needed (6GT2 801-3AB20-0AX0) (8 kb: 6GT2 800-4AC00)
Scanmode; Read only (32 kb: 6GT2 800-5AC00)

RF370T
(32 kb: 6GT2 800-5BE00)
(64 kb: 6GT2 800-6BE00)

RF380T
(6GT2 800-5DA00)

ISO TAGs
D100 6GT2 600-0AD10
D200 6GT2 600-1AD00-0AX0
D400 6GT2 600-4AD00
D117 6GT2 600-0AG00
D421 6GT2 600-4AE00
D422 6GT2 600-4AF00
D423 6GT2 600-4AA00
D124 6GT2 600-0AC10
D324 6GT2 600-3AC00
D424 6GT2 600-4AC00
D425 6GT2 600-4AG00
D126 6GT2 600-0AE00
D426 6GT2 600-4AH00
D127 6GT2 600-0AF00
D428 6GT2 600-4AK00-0AX0
D139 6GT2 600-0AA10
D339 6GT2 600-3AA10
D160 6GT2 600-0AB10
D460 6GT2 600-4AB00
D560 6GT2600-5AB00
D261 6GT2 600-1AA01-0AX0
D165 6GT2 600-1AB00-0AX0
Edition: August 2020 SIMATIC Ident Configuration Guide 35
RF600 Family Matrix Antennas
RF630L
6GT2 810-2AB02-0AX0
RF630L
6GT2 810-2AB01-0AX1
RF630L
6GT2 810-2AB03
RF630L
6GT2 810-2AB04
RF630L
6GT2810-2AC82
RF630L
6GT2 810-2AC84

Labels 96/240 bits EPC,


64 byte
256 bits EPC,
64 byte
96/240 bits EPC,
64 byte
256 bits EPC,
64 byte
128 bits EPC 448 bits EPC,
256 byte

865-868 MHz (ETSI)


902-928 MHz (FCC)
Passive Tags (with Gen2 protocol)
Operational Temperature Range -40°C to 80°C -40°C to 80°C -40°C to 80°C -20°C to 160°C -25°C to 90°C -40°C to 85°C
Dimensions ( L x W x D) mm 97 x 27 101 x 50 54 x 34 74 x 27 45 x 20 73 x 12,5
Ingress Protection (IP) Rating IP65 IP60 IP65 IP60 IP67 IP67

RF615R*** (IP67)
(internal antenna used)
6GT2811-6CC10-0AA0 (ETSI)
6GT2811-6CC10-1AA0 (FCC)
6GT2811-6CC10-2AA0 (CMIIT)
Integrated 1.0 1.0 0.6 0.6 0.4 0.5
(39) (39) (24) (24) (16) (20)
RF610R*** (IP67) 133 x 133 x 45
(internal antenna used)
6GT2811-6BC10-0AA0 (ETSI)
6GT2811-6BC10-1AA0 (FCC)
6GT2811-6BC10-2AA0 (CMIIT)
RF615A***

0.5 0.4 0.2 0.2 0.1 0.2


RF615R*** (IP67) (20) (16) (8) (8) (4) (8)
(external antenna used) 52 x 52 x 16
6GT2811-6CC10-0AA0 (ETSI) RF620A***
6GT2811-6CC10-1AA0 (FCC)
6GT2811-6CC10-2AA0 (CMIIT)
0.6 0.4 0.2 0.2 0.2 0.2
(24) (16) (8) (8) (8) (8)
75 x 75 x 20
RF642A**

4.0 3.5 1.6 1.8 3.0 3.0


(157) (138) (63) (71) (118) (118)
185 x 185 x 45
RF650A**

Antennas: 2.0 1.6 0.9 0.8 1.4 1.6


(79) (63) (35) (31) (55) (63)
6GT2 812-0EA00 RF615A, linear, (ETSI)
6GT2 812-0EA01 RF615A, linear, (FCC, CMIIT) 198 x 198 x 60
6GT2 812-1EA00 RF620A, linear, (ETSI) RF660A**
6GT2 812-1EA01 RF620A, linear, (FCC, CMIIT)
6GT2 812-1GA08 RF642A, linear, (all readers) 4.0 3.0 1.4 1.6 2.5 3.0
6GT2 812-0GB08 RF650A, circular, (all readers) (157) (118) (55) (63) (98) (118)
6GT2 812-0AA00 RF660A, circular, (ETSI) 313 x 313 x 80
6GT2 812-0AA01 RF660A, circular, (FCC, CMIIT)
RF680A**
6GT2 812-2GB08 RF680A, switchable, (all readers)
2.0 1.6 1.0 1.0 1.4 1.6
(79) (63) (39) (39) (55) (63)
198 x 198 x 60

** 3-way
mounting kit
Accessories (6GT2 890-2AB10)
*** mounting plate
(6GT2890-2AC00)

Maximum operating distance (m) and maximum operating distance (inch)


pay attention to the system manual for range overshoot
Edition: August 2020 SIMATIC Ident Configuration Guide 36
RF630L RF642L RF682L RF690L
RF600 Family Matrix Antennas 6GT2810-2AE81-0AX1
RF630L
6GT2810-2AE81-0AX3
RF630L
6GT2810-2AE80-0AX2 6GT2810-3AC00 (ETSI) 6GT2810-2AG84-0AX0 6GT2810-2AG00 (ETSI)

Labels 128 bits EPC 448 bit EPC, 256 Byte Up to 480 bits EPC, 6GT2810-3AC10 (FCC) 448 bits EPC, 256 Byte 6GT2810-2AG10 (FCC)
64/8 Byte 448 bit EPC, 96/480 bit EPC,
256 byte 64 byte
865-868 MHz (ETSI)
902-928 MHz (FCC)
Passive Tags (with Gen2 protocol) -25°C to 160°C
-40°C to 160°C -40°C to 120°C -25°C to 85°C -25°C to 85°C -40°C to 230°C 88 x 25 x 1.6
Operational Temperature Range
90 x 30 75 x 20 105 x 25 50 x 22.5 x 1.6 156 x 40 75 x 25 x 1.6
Dimensions ( L x W x D) mm
Ingress Protection (IP) Rating IP67 IP67 IP67 IP68 IP67 IP67

RF615R*** (IP67)
(internal antenna used)
6GT2811-6CC10-0AA0 (ETSI)
6GT2811-6CC10-1AA0 (FCC)
6GT2811-6CC10-2AA0 (CMIIT)
Integrated 0.6 0.5 1.6 0.8 1.0 0.2
(24) (20) (63) (31) (39) (8)
RF610R*** (IP67) 133 x 133 x 45
(internal antenna used)
6GT2811-6BC10-0AA0 (ETSI)
6GT2811-6BC10-1AA0 (FCC)
6GT2811-6BC10-2AA0 (CMIIT)
RF615A***

0.2 0.2 0.5 0.2 0.7 0.1


RF615R*** (IP67) (8) (8) (28) (8) (28) (4)
(external antenna used) 52 x 52 x 16
6GT2811-6CC10-0AA0 (ETSI) RF620A***
6GT2811-6CC10-1AA0 (FCC)
6GT2811-6CC10-2AA0 (CMIIT)
0.2 0.2 0.5 0.4 0.9 0.1
(8) (8) (20) (16) (35) (4)
75 x 75 x 20
RF642A**

2.5 3.0 4.0 2.0 4.5 0.3


(98) (118) (157) (79) (177) (12)
185 x 185 x 45
RF650A**

Antennas: 1.0 1.6 2.5 0.8 2.5 0.1


6GT2 812-0EA00 RF615A, linear, (ETSI)
(39) (63) (98) (31) (98) (4)
6GT2 812-0EA01 RF615A, linear, (FCC, CMIIT) 198 x 198 x 60
6GT2 812-1EA00 RF620A, linear, (ETSI) RF660A**
6GT2 812-1EA01 RF620A, linear, (FCC, CMIIT)
6GT2 812-1GA08 RF642A, linear, (all readers) 3.5 3.0 4.0 1.8 4.5 0.3
6GT2 812-0GB08 RF650A, circular, (all readers) (138) (118) (157) (71) (177) (12)
6GT2 812-0AA00 RF660A, circular, (ETSI) 313 x 313 x 80
6GT2 812-0AA01 RF660A, circular, (FCC, CMIIT)
RF680A**
6GT2 812-2GB08 RF680A, switchable, (all readers)
1.2 1.6 2.5 1.0 2.5 0.1
(47) (63) (98) (39) (98) (4)
198 x 198 x 60

** 3-way
mounting kit
Accessories (6GT2 890-2AB10)
*** mounting plate
(6GT2890-2AC00)

Maximum operating distance (m) and maximum operating distance (inch)


pay attention to the system manual for range overshoot
Edition: August 2020 SIMATIC Ident Configuration Guide 37
RF600 Family Matrix Antennas
RF610T
6GT2 810-2BB80
RF620T
6GT2 810-2HC81
RF625T
6GT2 810-2EE00 (ETSI)
RF630T
6GT2 810-2EC00 (ETSI)
RF640T
6GT2 810-2DC00 (ETSI)
RF645T
6GT2 810-2HC05
RF680T
6GT2 810-2HG80
RF682T
6GT2810-3HG80

Industrial Tags 6GT2 810-2BB80-0AX1* 6GT2 810-2EE01 (FCC) 6GT2 810-2EC10 (FCC) 6GT2 810-2DC10 (FCC)
96/128 bit EPC, 448 bit EPC, 96/240 bit EPC, 256 bit EPC,
96/128 bit EPC, 96/240 bit EPC, 96/240 bit EPC,
96/240 bit EPC, 64 byte 256 byte 64 byte 384 byte
64 byte 64 byte 64 byte 64 byte
865-868 MHz (ETSI)
902-928 MHz (FCC)
*
Passive Tags (with Gen2 protocol)
Operational Temperature Range -40°C to 85°C -40°C to 85°C -40°C to 125°C -40°C to 125°C -40°C to 125°C -40°C to 85°C -40°C to 220°C -40°C to 220°C
Dimensions ( L x W x D) mm 86 x 54 x 0.4 127 x 38 x 6 Ø 30 x 8 Ø 21x 20 Ø 50 x 8 52 x 36 x 12,5 130 x 32 x 15 130 x 32 x 15
Ingress Protection (IP) Rating IP67 IP67 IP68/ IPx9K IP68/ IPx9K IP68/ IPx9K IP68 IP68/ IPx9K IP68/ IPx9K

RF615R*** (IP67)
(internal antenna used)
6GT2811-6CC10-0AA0 (ETSI)
6GT2811-6CC10-1AA0 (FCC)
6GT2811-6CC10-2AA0 (CMIIT)
Integrated 0.8 1.6 0.3 0.3 0.4 1.0 1.0 1.0
(31) (63) (12) (12) (16) (39) (39) (39)
RF610R*** (IP67) 133 x 133 x 45
(internal antenna used)
6GT2811-6BC10-0AA0 (ETSI)
6GT2811-6BC10-1AA0 (FCC)
6GT2811-6BC10-2AA0 (CMIIT)
RF615A***

0.3 1.0 0.1 0.1 0.2 0.7 0.6 0.4


RF615R*** (IP67) (12) (39) (4) (4) (8) (28) (24) (16)
(external antenna used) 52 x 52 x 16
6GT2811-6CC10-0AA0 (ETSI) RF620A***
6GT2811-6CC10-1AA0 (FCC)
6GT2811-6CC10-2AA0 (CMIIT)
0.4 1.2 0.1 0.2 0.2 0.9 0.7 0.4
(16) (47) (4) (8) (8) (35) (28) (16)
75 x 75 x 20
RF642A**

3.0 4.0 1.0 0.5 1.4 3.0 4.0 2.5


(118) (157) (39) (20) (55) (118) (157) (98)
185 x 185 x 45
RF650A**

Antennas: 1.2 3.5 0.2 0.4 0.7 1.6 1.8 1.2


(47) (138) (8) (16) (28) (63) (71) (47)
6GT2 812-0EA00 RF615A, linear, (ETSI)
6GT2 812-0EA01 RF615A, linear, (FCC, CMIIT) 198 x 198 x 60
6GT2 812-1EA00 RF620A, linear, (ETSI) RF660A**
6GT2 812-1EA01 RF620A, linear, (FCC, CMIIT)
6GT2 812-1GA08 RF642A, linear, (all readers) 3.0 4.0 0.8 1.0 1.2 3.5 4.0 2.0
6GT2 812-0GB08 RF650A, circular, (all readers) (118) (157) (31) (39) (47) (138) (157) (79)
6GT2 812-0AA00 RF660A, circular, (ETSI) 313 x 313 x 80
6GT2 812-0AA01 RF660A, circular, (FCC, CMIIT)
RF680A**
6GT2 812-2GB08 RF680A, switchable, (all readers)
1.4 4.0 0.2 0.5 1.2 1.8 2.0 1.2
(55) (157) (8) (20) (47) (71) (79) (47)
198 x 198 x 60
** 3-way Mounting cover
20 mm Spacer
mounting kit (6GT2 190-0AA00) Spacer 6GT2898-5AA00 Retaining bracket Retaining bracket
Accessories (6GT2 890-2AB10) Fixing pocket (6GT2 898-2AA00) Retaining bracket 6GT2890-2AA00 6GT2890-2AA00
*** mounting plate (6GT2 190-0AB00)
(6GT2890-2AC00) 6GT2898-5AB00

Maximum operating distance (m) and maximum operating distance (inch)


pay attention to the system manual for range overshoot
Edition: August 2020 SIMATIC Ident Configuration Guide 38
RF600 Family Matrix Antennas
RF630L
6GT2 810-2AB02-0AX0
RF630L
6GT2 810-2AB01-0AX1
RF630L
6GT2 810-2AB03
RF630L
6GT2 810-2AB04
RF630L
6GT2810-2AC82
RF630L
6GT2 810-2AC84

Labels 96/240 bits EPC,


64 byte
256 bits EPC,
64 byte
96/240 bits EPC,
64 byte
256 bits EPC,
64 byte
128 bits EPC 448 bits EPC,
256 byte

865-868 MHz (ETSI)


902-928 MHz (FCC)
Passive Tags (with Gen2 protocol)
Operational Temperature Range -40°C to 80°C -40°C to 80°C -40°C to 80°C -20°C to 160°C -25°C to 90°C -40°C to 85°C
Dimensions ( L x W x D) mm 97 x 27 101 x 50 54 x 34 74 x 27 45 x 20 73 x 12,5
Ingress Protection (IP) Rating IP65 IP60 IP65 IP60 IP67 IP67

RF685R** (IP65)
(internal antenna used)
Integrated 6.0 5.0 3.0 3.5 5.0 5.0
6GT2811-6CA10-0AA0 (ETSI) (236) (197) (118) (138) (197) (197)
6GT2811-6CA10-1AA0 (FCC) 260 x 193 x 52
6GT2811-6CA10-2AA0 (CMIIT)
6GT2811-6CA10-4AA0 (ARIB)

RF615A***

RF685R** (IP65) 1.8 / *1.2 1.4 / *1.0 0.7 / *0.5 0.8 / *0.6 1.0 / *0.7 1.4 / *1.0
(external antenna used) (71 / *47) (55 / *39) (28 / *20) (31 / *24) (39 / *28) (55 / *39)
6GT2811-6CA10-0AA0 (ETSI) 52 x 52 x 16
6GT2811-6CA10-1AA0 (FCC)
RF620A***
6GT2811-6CA10-2AA0 (CMIIT)
6GT2811-6CA10-4AA0 (ARIB) 1.8 / *1.2 1.6 / *1.0 0.8 / *0.5 0.9 / *0.7 1.2 / *0.8 1.4 / *1.0
(71 / *47) (63 / *39) (31 / *20) (35 / *28) (47/ *31) (55 / *39)
RF680R** (IP65) 75 x 75 x 20
6GT2811-6AA10-0AA0 (ETSI) RF642A**
6GT2811-6AA10-1AA0 (FCC)
6GT2811-6AA10-2AA0 (CMIIT) 5.0 5.0 3.0 3.5 5.0 / *4.5 5.0
6GT2811-6AA10-4AA0 (ARIB) (197) (197) (118) (138) (197 / *177) (197)
185 x 185 x 45
RF650R** (IP30) RF650A**
6GT2811-6AB20-0AA0 (ETSI) 4.0 / *3.0 3.4 / *3.0 1.8 / *1.4 2.5 / *1.8 3.0 / *2.0 3.5 / *2.5
6GT2811-6AB20-1AA0 (FCC) (157 / *118) (134 / *118) (71 / *55) (98 / *71) (118 / *79) (138 / *98)
6GT2811-6AB20-2AA0 (CMIIT)
198 x 198 x 60
6GT2811-6AB20-4AA0 (ARIB)
RF660A**
Antennas:
6GT2 812-0EA00 RF615A, linear, (ETSI)
5.0 5.0 2.5 3.0 4.0 4.0
(197) (197) (98) (118) (157) (157)
6GT2 812-0EA01 RF615A, linear, (FCC, CMIIT, ARIB)
6GT2 812-1EA00 RF620A, linear, (ETSI) 313 x 313 x 80
6GT2 812-1EA01 RF620A, linear, (FCC, CMIIT, ARIB)
6GT2 812-1GA08 RF642A, linear, (all readers) RF680A**
6GT2 812-0GB08 RF650A, circular, (all readers)
6GT2 812-0AA00 RF660A, circular, (ETSI) 4.5 / *3.0 4.0 / *3.0 1.8 / *1.4 2.5 / *1.8 3.0 / *2.0 3.5 / *2.5
6GT2 812-0AA01 RF660A, circular, (FCC, CMIIT, ARIB) (177 / *118) (157 / *118) (71 / *55) (98 / *71) (118 / *79) (138 / *98)
6GT2 812-2GB08 RF680A, switchable, (all readers) 198 x 198 x 60

** 3-way
mounting kit
Accessories (6GT2 890-2AB10)
*** mounting plate
(6GT2890-2AC00)

Maximum operating distance (m) and maximum operating distance (inch) * Use this value in combination with RF650R
pay attention to the system manual for range overshoot
Edition: August 2020 SIMATIC Ident Configuration Guide 39
RF630L RF682L RF690L
RF600 Family Matrix Antennas
RF630L
6GT2810-2AE81-0AX1
RF630L
6GT2810-2AE81-0AX3 6GT2810-2AE80-0AX2
RF642L
6GT2810-3AC00 (ETSI) 6GT2810-2AG84-0AX0 6GT2810-2AG00 (ETSI)

Labels 128 bits EPC 448 bit EPC, 256 Byte Up to 480 bits EPC, 6GT2810-3AC10 (FCC) 448 bits EPC, 256 Byte 6GT2810-2AG10 (FCC)
64/8 byte 448 bit EPC, 96/496 bit EPC,
256 byte 64 byte
865-868 MHz (ETSI)
902-928 MHz (FCC)
Passive Tags (with Gen2 protocol) -25°C to 160°C
-40°C to 160°C -40°C to 120°C -25°C to 85°C -25°C to 85°C -40°C to 230°C 88 x 25 x 1.6
Operational Temperature Range
90 x 30 75 x 20 105 x 25 50 x 22.5 x 1.6 156 x 40 75 x 25 x 1.6
Dimensions ( L x W x D) mm
Ingress Protection (IP) Rating IP67 IP67 IP67 IP68 IP67 IP67

RF685R** (IP65)
(internal antenna used)
Integrated 3.5 5.0 6.0 2.0 6.0 3.0
6GT2811-6CA10-0AA0 (ETSI) (138) (197) (236) (79) (236) (118)
6GT2811-6CA10-1AA0 (FCC) 260 x 193 x 52
6GT2811-6CA10-2AA0 (CMIIT)
6GT2811-6CA10-4AA0 (ARIB)

RF615A***

RF685R** (IP65) 0.8 / *0.6 1.4 / *1.0 1.8 / *1.4 0.5 / *0.4 1.6 / *1.2 0.2 / *0.2
(external antenna used) (31 / *24) (55 / *39) (71 / *55) (20 / *16) (63 / *47) (8 / *8)
6GT2811-6CA10-0AA0 (ETSI) 52 x 52 x 16
6GT2811-6CA10-1AA0 (FCC)
RF620A***
6GT2811-6CA10-2AA0 (CMIIT)
6GT2811-6CA10-4AA0 (ARIB) 0.9 / *0.6 1.4 / *1.0 2.0 / *1.4 0.5 / *0.4 1.8 / *1.2 0.3 / *0.2
(35/ *24) (55 / *39) (79 / *55) (20 / *16) (71 / *47) (12 / *8)
RF680R** (IP65) 75 x 75 x 20
6GT2811-6AA10-0AA0 (ETSI) RF642A**
6GT2811-6AA10-1AA0 (FCC)
6GT2811-6AA10-2AA0 (CMIIT) 3.5 5.0 6.0 2.0 6.0 2.0
6GT2811-6AA10-4AA0 (ARIB) (138) (197) (236) (79) (236) (79)
185 x 185 x 45
RF650R** (IP30) RF650A**
6GT2811-6AB20-0AA0 (ETSI) 2.5 / *1.8 3.5 / *2.5 5.0 / *3.5 1.6 / *1.2 4.0 / *3.0 3.5 / *3.0
6GT2811-6AB20-1AA0 (FCC) (98 / *71) (138 / *98) (197 / *138) (63 / *47) (157 / *118) (138 / *118)
6GT2811-6AB20-2AA0 (CMIIT)
198 x 198 x 60
6GT2811-6AB20-4AA0 (ARIB)
RF660A**
Antennas:
6GT2 812-0EA00 RF615A, linear, (ETSI)
3.0 4.0 6.0 1.6 5.0 1.4
(118) (157) (236) (63) (197) (55)
6GT2 812-0EA01 RF615A, linear, (FCC, CMIIT, ARIB)
6GT2 812-1EA00 RF620A, linear, (ETSI) 313 x 313 x 80
6GT2 812-1EA01 RF620A, linear, (FCC, CMIIT, ARIB)
6GT2 812-1GA08 RF642A, linear, (all readers) RF680A**
6GT2 812-0GB08 RF650A, circular, (all readers)
6GT2 812-0AA00 RF660A, circular, (ETSI) 2.5 / *1.8 3.5 / *2.5 5.0 / *3.5 1.6 / *1.2 5.0 / *3.0 1.4 / *0.9
6GT2 812-0AA01 RF660A, circular, (FCC, CMIIT, ARIB) (98/ *71) (138 / *98) (197 / *138) (63 / *47) (197 / *118) (55 / *35)
6GT2 812-2GB08 RF680A, switchable, (all readers) 198 x 198 x 60

** 3-way
mounting kit
Accessories (6GT2 890-2AB10)
*** mounting plate
(6GT2890-2AC00)

Maximum operating distance (m) and maximum operating distance (inch) * Use this value in combination with RF650R
pay attention to the system manual for range overshoot
Edition: August 2020 SIMATIC Ident Configuration Guide 40
RF600 Family Matrix Antennas
RF610T
6GT2 810-2BB80
RF620T
6GT2 810-2HC81
RF625T
6GT2 810-2EE00 (ETSI)
RF630T
6GT2 810-2EC00 (ETSI)
RF640T
6GT2 810-2DC00 (ETSI)
RF645T
6GT2 810-2HC05
RF680T
6GT2 810-2HG80
RF682T
6GT2810-3HG80

Industrial Tags 6GT2 810-2BB80-0AX1* 6GT2 810-2EE01 (FCC) 6GT2 810-2EC10 (FCC) 6GT2 810-2DC10 (FCC)
96/128 bit EPC, 448 bit EPC, 96/240 bit EPC, 224 bit EPC,
96/128 bit EPC, 96/240 bit EPC, 96/240 bit EPC,
96/240 bit EPC, 64 byte 256 byte 64 byte 384 byte
64 byte 64 byte 64 byte 64 byte
865-868 MHz (ETSI)
902-928 MHz (FCC)
*
Passive Tags (with Gen2 protocol)
Operational Temperature Range -40°C to 85°C -40°C to 85°C -40°C to 125°C -40°C to 125°C -40°C to 125°C -40°C to 85°C -40°C to 220°C -40°C to 220°C
Dimensions ( L x W x D) mm 86 x 54 x 0.4 127 x 38 x 6 Ø 30 x 8 Ø 21x 20 Ø 50 x 8 52 x 36 x 12,5 130 x 32 x 15 130 x 32 x 15
Ingress Protection (IP) Rating IP67 IP67 IP68/ IPx9K IP68/ IPx9K IP68/ IPx9K IP68 IP68/ IPx9K IP68/ IPx9K

RF685R** (IP65)
(internal antenna used)
Integrated 5.0 7.0 2.0 2.0 3.5 6.0 5.0 4.0
6GT2811-6CA10-0AA0 (ETSI) (197) (276) (79) (79) (138) (236) (197) (157)
6GT2811-6CA10-1AA0 (FCC) 260 x 193 x 52
6GT2811-6CA10-2AA0 (CMIIT)
6GT2811-6CA10-4AA0 (ARIB)

RF615A***

RF685R** (IP65) 1.2 / *0.9 2.5 / *1.8 0.5 / *0.3 0.5 / *0.4 0.8 / *0.6 1.8 / *1.2 1.4 / *1.0 1.0 / *0.7
(external antenna used) (47 / *35) (98 / *71) (20 / *12) (20 / *16) (31 / *24) (71 / *47) (55 / *39) (39 / *28)
52 x 52 x 16
6GT2811-6CA10-0AA0 (ETSI)
6GT2811-6CA10-1AA0 (FCC)
RF620A***
6GT2811-6CA10-2AA0 (CMIIT)
6GT2811-6CA10-4AA0 (ARIB) 1.4 / *0.9 2.5 / *1.8 0.5 / *0.4 0.5 / *0.4 1.0 / *0.7 2.0 / *1.4 1.6 / *1.2 1.2 / *0.8
(55 / *35) (98 / *71) (20 / *16) (20 / *16) (39 / *28) (79 / *55) (63 / *47) (47 / *31)
RF680R** (IP65) 75 x 75 x 20
6GT2811-6AA10-0AA0 (ETSI) RF642A**
6GT2811-6AA10-1AA0 (FCC)
6GT2811-6AA10-2AA0 (CMIIT) 4.5 8.0 1.8 2.0 4.0 / *2.5 6.0 5.0 4.5
6GT2811-6AA10-4AA0 (ARIB) (177) (315) (71) (79) (157 / *98) (236) (197) (177)
185 x 185 x 45

RF650R** (IP30) RF650A**


6GT2811-6AB20-0AA0 (ETSI) 3.0 / *2.0 5.0 / *4.0 1.4 / *1.0 1.2 / *0.9 2.5 / *2.0 5.0 / *3.5 4.0 / *3.0 2.5 / *2.0
6GT2811-6AB20-1AA0 (FCC) (118 / *79) (197 / *157) (55 / *39) (47 / *35) (98 / *79) (197 / *138) (157 / *118) (98 / *79)
6GT2811-6AB20-2AA0 (CMIIT)
198 x 198 x 60
6GT2811-6AB20-4AA0 (ARIB)
RF660A**
Antennas:
6GT2 812-0EA00 RF615A, linear, (ETSI)
3.5 6.0 1.4 1.8 3.0 / *2.0 5.0 4.5 4.0
6GT2 812-0EA01 RF615A, linear, (FCC, CMIIT, ARIB) (138) (236) (55) (71) (118 / *79) (197) (177) (157)
6GT2 812-1EA00 RF620A, linear, (ETSI) 313 x 313 x 80
6GT2 812-1EA01 RF620A, linear, (FCC, CMIIT, ARIB)
6GT2 812-1GA08 RF642A, linear, (all readers) RF680A**
6GT2 812-0GB08 RF650A, circular, (all readers)
6GT2 812-0AA00 RF660A, circular, (ETSI)
3.0 / *2.0 6.0 / *4.0 1.2 / *0.8 1.2 / *0.9 3.0 /*2.0 4.5 / *3.0 4.5 / *3.0 3.0 / *2.0
(118 / *79) (236 / *157) (47 / *31) (47 / *35) (118 / *79) (177 / *118) (177 /*118) (118 / *79)
6GT2 812-0AA01 RF660A, circular, (FCC, CMIIT, ARIB)
6GT2 812-2GB08 RF680A, switchable, (all readers) 198 x 198 x 60
** 3-way Mounting cover
20 mm Spacer
mounting kit (6GT2 190-0AA00) Spacer 6GT2898-5AA00 Retaining bracket Retaining bracket
Accessories (6GT2 890-2AB10) Fixing pocket (6GT2 898-2AA00) Retaining bracket 6GT2890-2AA00 6GT2890-2AA00
*** mounting plate (6GT2 190-0AB00)
(6GT2890-2AC00) 6GT2898-5AB00

Maximum operating distance (m) and maximum operating distance (inch) * Use this value in combination with RF650R
pay attention to the system manual for range overshoot
Edition: August 2020 SIMATIC Ident Configuration Guide 41
RF600 System Interfaces
PROFINET & OPC UA & Ethernet/IP & TCP/IP Reader Labels

+ Direct connection
Ethernet /PN Cable M12
length from 2 to 15 m available; e.g. 2 m = 6XV1871-5TH20 (no switch required)
+ RF630L
6GT2 810-2AB02-0AX0
6GT2 810-2AB01-0AX1
Connection with 6GT2 810-2AB03
6GT2810-2AB04
RF610R
Network Connection via Switch external power (only internal antenna)
6GT2810-2AC82
6GT2810-2AC84

+
Controller Library supply
+ + +
6GT2811-6BC10-0AA0 (ETSI) 6GT2 810-2AE81-0AX1
length from
and Demo-Software 0.5 to 50 m available
6GT2811-6BC10-1AA0 (FCC) 6GT2 810-2AE81-0AX3
Ethernet /PN Cable M12 6GT2811-6BC10-2AA0 (CMIIT) 6GT2810-2AE80-0AX2
on DVD e.g. 2 m = 6XV1870-3QH20
length from 2 to 15 m available RF642L
e.g. 2 m = 6XV1871-5TH20 6GT2 810-3AC00 (ETSI)
General host application as
6GT2 810-3AC10 (FCC)
a, XML client IE switch SCALANCE X
b, Off-the-shelf third-party RFID Middleware (6GK5 …) RF682L
c, OPC UA for AutoID Client 6GT2810-2AG84-0AX0
Controller Application written in RF690L
RF615R 6GT2 810-2AG00 (ETSI)
any controller language using Ident library
(internal antenna and 6GT2 810-2AG10 (FCC)
with Ident profile
optional 1 ext. antenna)
6GT2811-6CC10-0AA0 (ETSI) Tags
6GT2811-6CC10-1AA0 (FCC)
6GT2811-6CC10-2AA0 (CMIIT)
Power supply External antennas:
EU connector RF610T
6GT2 898-0AC00 RF615A 6GT2 810-2BB80
6GT2 812-0EA00; ETSI 6GT2 810-2BB80-0AX1
UK connector 6GT2 812-0EA01; FCC, etc.
6GT2 898-0AC10
RF620A
US connector 6GT2812-1EA00, ETSI RF620T
6GT2 898-0AC20 6GT2812-1EA01, FCC, etc. 6GT2 810-2HC81
cable 24 V for power supply
5 m = 6GT2 891-0PH50 RF642A
6GT2 812-1GA08
cable w/ open ends
2 m = 6GT2 891-4EH20 RF650A RF625T
5 m = 6GT2 891-4EH50 6GT2 812-0GB08 6GT2 810-2EE00 (ETSI)
6GT2 810-2EE01 (FCC)
RF660A
6GT2 812-0AA00, ETSI
6GT2 812-0AA01, FCC, etc.
RF680A RF630T
6GT2 812-2GB08 6GT2 810-2EC00 (ETSI)
Antenna Cable 6GT2 810-2EC10 (FCC)
1m = 6GT2815-0BH10
3m = 6GT2 815-0BH30

PROFIBUS Powered through


5m, flex = 6GT2 815-2BH50
10m,2dB = 6GT2 815-1BN10
10m,4dB = 6GT2 815-0BN10 RF640T Gen2
connection cable 15m,flex = 6GT2 815-2BN15 6GT2 810-2DC00 (ETSI)
20m = 6GT2 815-0BN20 6GT2 810-2DC10 (FCC)
A maximum of 2 readers may be connected
+ +
40m = 6GT2 815-0BN40
Power Splitter
RF166C to RF6x0R 6GT2 890-0BC00
RF645T
DI/DO interface
2 m = 6GT2 891-4FH20 5 m = 6GT2 891-4FH50 Use a M12 A-coded connector 6GT2 810-2HC05
10 m = 6GT2 891-4FN10 20 m = 6GT2 891-4FN20 3RK1902-4BA00-5AA0
50 m = 6GT2 891-4FN50* Cover caps
6GT2898-4AA10 RF680T
Reader connector 90° angled 6GT2 810-2HG80
Opt.: 3-way mounting kit
RF166C (DP-V1) 2 m = 6GT2 891-4JH20 5 m = 6GT2 891-4JH50 6GT2890-2AB10
Communication Module 10 m = 6GT2 891-4JN10 Opt.: Mounting plate
(6GT2 002-0EE20) 6GT2890-2AC00
RF682T
6GT2 810-3HG80

Edition: August 2020 SIMATIC Ident Configuration Guide 42


RF600 System Interfaces
Ethernet TCP/IP Reader Labels

+ Direct connection
RF650R Ethernet Connection Cable
0.5 to 50 m available; e.g. 2 m = 6XV1870-3QH20 (no switch required)
+ with external power supply
RF615A
6GT2 812-0EA00; ETSI
RF630L
6GT2 810-2AB02-0AX0
6GT2 810-2AB01-0AX1
6GT2 812-0EA01; FCC, etc. 6GT2 810-2AB03
6GT2810-2AB04
RF620A 6GT2810-2AC82
Network Connection via Switch 6GT2812-1EA00, ETSI
6GT2810-2AC84

+ + + +
Demo-Software 6GT2812-1EA01, FCC, etc.
6GT2 810-2AE81-0AX1
length from
on DVD 0.5 to 50 m available RF642A 6GT2 810-2AE81-0AX3
e.g. 2 m = 6XV1870-3QH20 RF650R Ethernet Connection Cable 6GT2 812-1GA08 6GT2810-2AE80-0AX2
0.5 to 50 m available RF642L
RF650A 6GT2 810-3AC00 (ETSI)
e.g. 2 m = 6XV1870-3QH20 6GT2 812-0GB08 6GT2 810-3AC10 (FCC)
IE Switch SCALANCE X RF650R
Host application as (6GK5 …) (1 to 4 ext. antennas)
RF660A RF682L
a, XML client 6GT2 812-0AA00, ETSI 6GT2810-2AG84-0AX0
b, Off-the-shelf third-party RFID Middleware 6GT2811-6AB20-0AA0 (ETSI) 6GT2 812-0AA01, FCC, etc.
6GT2811-6AB20-1AA0 (FCC) RF690L
c, OPC UA for AutoID Client 6GT2811-6AB20-2AA0 (CMIIT)
RF680A 6GT2 810-2AG00 (ETSI)
6GT2811-6AB20-4AA0 (ARIB) 6GT2 812-2GB08 6GT2 810-2AG10 (FCC)
Antenna Mounting kit
6GT2 890-2AB10 Tags
PROFINET & OPC UA & Ethernet/IP & TCP/IP Antenna Cable

+ Direct connection
+
1m = 6GT2815-0BH10
3m = 6GT2 815-0BH30 RF610T
Ethernet /PN Cable M12 5m, flex = 6GT2 815-2BH50 6GT2 810-2BB80
10m,2dB = 6GT2 815-1BN10 6GT2 810-2BB80-0AX1
length from 2 to 15 m available; e.g. 2 m = 6XV1871-5TH20 (no switch required)
10m,4dB = 6GT2 815-0BN10
15m,flex = 6GT2 815-2BN15
20m = 6GT2 815-0BN20 RF620T
Network Connection via Switch 40m = 6GT2 815-0BN40 6GT2 810-2HC81

+
Controller Library

+ + +
length from RF680R Power Splitter
and Demo-Software 0.5 to 50 m available (1 to 4 ext. antennas) 6GT2 890-0BC00
Ethernet /PN Cable M12
on DVD e.g. 2 m = 6XV1870-3QH20
length from 2 to 15 m available 6GT2811-6AA10-0AA0 (ETSI) (do not use with RF680A)
RF625T
6GT2811-6AA10-1AA0 (FCC)
e.g. 2 m = 6XV1871-5TH20 6GT2811-6AA10-2AA0 (CMIIT) 6GT2 810-2EE00 (ETSI)
General host application as 6GT2 810-2EE01 (FCC)
a, XML client IE switch SCALANCE X
6GT2811-6AA10-4AA0 (ARIB) Power supply
b, Off-the-shelf third-party RFID Middleware (6GK5 …) EU connector
c, OPC UA for AutoID Client 6GT2 898-0AC00
Controller Application written in UK connector RF630T
any controller language using Ident library 6GT2 898-0AC10 6GT2 810-2EC00 (ETSI)
with Ident profile 6GT2 810-2EC10 (FCC)
US connector
6GT2 898-0AC20
cable 24 V for power supply
5 m = 6GT2 891-0PH50
RF685R RF640T Gen2
cable w/ open ends 6GT2 810-2DC00 (ETSI)
(internal antenna and 2 m = 6GT2 891-4EH20 6GT2 810-2DC10 (FCC)
optional 1 ext. antenna) 5 m = 6GT2 891-4EH50
6GT2811-6CA10-0AA0 (ETSI) optional
6GT2811-6CA10-1AA0 (FCC)
6GT2811-6CA10-2AA0 (CMIIT) RF645T
DI/DO cable 5m 6GT2 810-2HC05
6GT2811-6CA10-4AA0 (ARIB)
6GT2891-0CH50
3-way mounting kit
Cover caps 6GT2890-2AB10 RF680T
(6GT2898-4AA10) Mounting plate 6GT2 810-2HG80
6GT2890-2AC00
Rail mounting set RF682T
6GT2890-0AB00 6GT2 810-3HG80

Edition: August 2020 SIMATIC Ident Configuration Guide 43


RF600 System Interfaces

PROFIBUS Reader Labels


powered through connection cable
RF630L
A maximum of 2 readers may be connected
+ + RF615A 6GT2 810-2AB02-0AX0
6GT2 812-0EA00; ETSI 6GT2 810-2AB01-0AX1
RF166C to RF6x0R 6GT2 812-0EA01; FCC, etc. 6GT2 810-2AB03
2 m = 6GT2 891-4FH20 5 m = 6GT2 891-4FH50 6GT2810-2AB04
10 m = 6GT2 891-4FN10 20 m = 6GT2 891-4FN20
RF620A 6GT2810-2AC82
6GT2812-1EA00, ETSI 6GT2810-2AC84
50 m = 6GT2 891-4FN50*
6GT2812-1EA01, FCC, etc. 6GT2 810-2AE81-0AX1
Reader connector 90° angled RF642A 6GT2 810-2AE81-0AX3
RF166C (DP-V1) 2 m = 6GT2 891-4JH20 5 m = 6GT2 891-4JH50 6GT2 812-1GA08
6GT2810-2AE80-0AX2
Communication Module 10 m = 6GT2 891-4JN10 RF642L
(6GT2 002-0EE20) RF650A 6GT2 810-3AC00 (ETSI)
6GT2 812-0GB08 6GT2 810-3AC10 (FCC)
RF660A RF682L
RF680R 6GT2 812-0AA00, ETSI 6GT2810-2AG84-0AX0
(1 to 4 ext. antennas) 6GT2 812-0AA01, FCC, etc.
RF690L
6GT2811-6AA10-0AA0 (ETSI)
6GT2811-6AA10-1AA0 (FCC)
RF680A 6GT2 810-2AG00 (ETSI)
6GT2 812-2GB08 6GT2 810-2AG10 (FCC)
6GT2811-6AA10-2AA0 (CMIIT)
6GT2811-6AA10-4AA0 (ARIB)
Tags
Antenna Cable
1m = 6GT2815-0BH10
3m = 6GT2 815-0BH30 RF610T
5m, flex = 6GT2 815-2BH50
6GT2 810-2BB80
10m,2dB = 6GT2 815-1BN10
6GT2 810-2BB80-0AX1
10m,4dB = 6GT2 815-0BN10
15m,flex = 6GT2 815-2BN15
20m = 6GT2 815-0BN20
40m = 6GT2 815-0BN40 RF620T
6GT2 810-2HC81
RF685R Power Splitter
(internal antenna and 6GT2 890-0BC00
(do not use with RF680A)
optional 1 ext. antenna)
RF625T
6GT2811-6CA10-0AA0 (ETSI)
6GT2 810-2EE00 (ETSI)
6GT2811-6CA10-1AA0 (FCC)
6GT2 810-2EE01 (FCC)
6GT2811-6CA10-2AA 0 (CMIIT)
6GT2811-6CA10-4AA0 (ARIB)

Cover caps RF630T


(6GT2898-4AA10) 6GT2 810-2EC00 (ETSI)
6GT2 810-2EC10 (FCC)

RF640T Gen2
6GT2 810-2DC00 (ETSI)
optional 6GT2 810-2DC10 (FCC)
DI/DO cable 5m
6GT2891-0CH50
RF645T
3-way mounting kit 6GT2 810-2HC05
6GT2890-2AB10

Mounting plate RF680T


6GT2890-2AC00 6GT2 810-2HG80

Rail mounting set


6GT2890-0AB00 RF682T
6GT2 810-3HG80

Edition: August 2020 SIMATIC Ident Configuration Guide 44


RF1000 D100 D200 D400 D126 D426 D526
6GT2 600-0AD10 6GT2 600-1AD00 -0AX0 6GT2 600-4AD00
Family Matrix
6GT2 600-0AE00 6GT2 600-4AH00 6GT2 600-5AH00
112 byte EEPROM 256 byte EEPROM 2 kbyte FRAM 112 byte EEPROM 2 kbyte FRAM 8 kbyte FRAM

13.56 MHz / ISO 15693


Passive Tags

Operational temperature range -25°C to 80°C -20°C to 60°C -20°C to 60°C -40°C to 100°C -40°C to 100°C -40°C to 100°C
Dimensions (L x W x D) mm 85,6 x 54 x 0.9 85.6 x 54 x 0.8 85.6 x 54 x 0.8 Ø 50 x 3.6 Ø 50 x 3.6 Ø 50 x 3.6
Ingress Protection (IP) rating
IP68 IP67 IP67 IP68 IP68 IP68

RF1040R (USB, RS232) 30 30 30 30 30 30


6GT2831-6CA50 (1.18) (1.18) (1.18) (1.18) (1.18) (1.18)

RF1060R (USB) 30 30** 30 30 30 30


6GT2831-6AA50 (1.18) (1.18) (1.18) (1.18) (1.18) (1.18)

RF1070R (USB, RS232)


6GT2831-6BA50
6GT2831-6BA50-0AX0 (OEM*)
30 30 30
(1.18) (1.18) (1.18)

* ATEX not valid for OEM type)


** only for read-only access

Maximum Distance for Stationary Tag (mm)


Maximum Distance for Stationary Tag (inch)

Edition: August 2020 SIMATIC Ident Configuration Guide 45


RF1000 E600 E611 ISO 14443 Legic 125 kHz (LF)
6GT2 300-0AA00 6GT2 300-0BB00
Family Matrix 752 byte EEPROM 752 byte EEPROM

13.56 MHz others


125 kHz passive tags
Company badges Company badges Company badges
Operational temperature range and transponders and Transponders and Transponders
Dimensions (L x W x D) mm -25°C to 60°C -40°C to 85°C acc. ISO 14443 A/B acc. Legic Prime acc. Hitag 1/2/S
Ingress Protection (IP) rating 86 x 54 x 0.76 86 x 54 x 2.5 and Legic Advant EM41xx, EKS and more
IP68 IP67

RF1040R (USB, RS232) 30 30 30 30


6GT2831-6CA50 (1.18) (1.18) (1.18) (1.18)

RF1060R (USB) 30 30 30
6GT2831-6AA50 (1.18) (1.18) (1.18)

RF1070R (USB, RS232)


6GT2831-6BA50
6GT2831-6BA50-0AX0 (OEM*)
30 30 30 30
(1.18) (1.18) (1.18) (1.18)

* ATEX not valid for OEM type)

Maximum Distance for Stationary Tag (mm)


Maximum Distance for Stationary Tag (inch)

Edition: August 2020 SIMATIC Ident Configuration Guide 46


RF1000 System Interfaces

USB Reader Tags


Powered through USB cable

1 Reader per USB port type A D100 (6GT2 600-0AD10)


Optional: D200 (6GT2 600-1AD00 -0AX0)
(USB cable 1.8 m included) D400 (6GT2 600-4AD00)*

Card holder

+
Optional: short USB cable
D126 (6GT2 600-0AE00)
0.5 m = 6GT2 891-0UE50 D426 (6GT2 600-4AH00)*
D526 (6GT2 600-5AH00)*
6GT2 890-0CA00

RF1040R
(6GT2 831-6CA50)
DLL and simple Demo for PC: Config–Card Company badges
https://support.industry.siemens.com/cs/ww/en/view/109741590 (for customer-specific and transponders
reader configuration) acc. ISO 14443 A/B
Incl. MDS E600/E611
Local user administration for
Comfort Panels and IPC:
https://support.industry.siemens.com/cs/ww/en/view/99808171
https://support.industry.siemens.com/cs/de/en/view/109754400 (SIMATIC HMI Option+)
6GT2300-0CC00-0AX0
Transponders
Central user management PM Logon acc. ISO 15693
https://www.siemens.com/pm-logon RF1060R
(6GT2 831-6AA50)
https://support.industry.siemens.com/cs/ww/en/view/109779685 Extension unit IP65
**)
for operator controls
SIMATIC Logon / Logon Remote Access
https://support.industry.siemens.com/cs/ww/en/view/109749167 12’’ 6AV7674-1LA31-0AA0
Company badges
15’’ 6AV7674-1LA41-0AA0 and Transponders
19’’ 6AV7674-1LA51-0AA0 acc. Legic Prime
and Legic Advant
22’’ 6AV7674-1LA61-0AA0

***)

RF1070R
(6GT2 831-6BA50) Company badges
(6GT2 831-6BA50-0AX0, and Transponders
OEM**** ) acc. Hitag 1/2/S,
EM41xx, EKS and more

Tag restrictions:
* not for RF1070R
** only with RF1070R
**** ATEX not valid for OEM type) *** only with RF1040R

Edition: August 2020 SIMATIC Ident Configuration Guide 47


RF1000 System Interfaces

PROFINET & Ethernet/IP Reader Tags


Powered through connection cable
Communication Modules
A maximum of
1 reader at RF185C,
2 readers at RF186C/CI, RF188C/CI D100 (6GT2 600-0AD10)
of RF1000 may be connected (RS232) Optional: D200 (6GT2 600-1AD00 -0AX0)

RF185C RF186C RF188C


(6GT2 002-0JE10) (6GT2 002-0JE20) (6GT2 002-0JE40)
+ Connection cable:
+ Card holder
D400 (6GT2 600-4AD00)*

2m = 6GT2891-4UH20
D126 (6GT2 600-0AE00)
(do not use an additional D426 (6GT2 600-4AH00)*
extension cable) D526 (6GT2 600-5AH00)*
Additional IOs 6GT2 890-0CA00
RF1040R
(6GT2 831-6CA50)

Types of IO-Link Config–Card Company badges

+ RF18xCI to sensor
+ IO module
IO-extension module
(for customer-specific
reader configuration)
and transponders
acc. ISO 14443 A/B
Incl. MDS E600/E611
RF186CI RF188CI Sensor cable from 6ES7 14….. (up to 8xDI + 8xDO)
(6GT2 002-0JE50) (6GT2 002-0JE60) 0.5 to 15 m available
(e.g. 2 m = 6XV1801-2CH20) See page 76 for detailed information

6GT2300-0CC00-0AX0
Transponders
Or one acc. ISO 15693
Standard sensor
Extension unit IP65
Or one RF1070R **)
for operator controls
Actor (6GT2 831-6BA50)
(6GT2 831-6BA50-0AX0, 12’’ 6AV7674-1LA31-0AA0
Company badges
OEM**** )
15’’ 6AV7674-1LA41-0AA0 and Transponders
19’’ 6AV7674-1LA51-0AA0 acc. Legic Prime
and Legic Advant
22’’ 6AV7674-1LA61-0AA0

***)

PROFIBUS A maximum of 2 readers Company badges


may be connected (RS232) and Transponders

+ Connection cable:
2m = 6GT2891-4UH20
+ acc. Hitag 1/2/S,
EM41xx, EKS and more

(do not use an additional


extension cable)

RF166C (DP-V1)
Communication Module Tag restrictions:
(6GT2 002-0EE20)
* not for RF1070R
** only with RF1070R

**** ATEX not valid for OEM type) *** only with RF1040R

Edition: August 2020 SIMATIC Ident Configuration Guide 48


RF1000 System Interfaces

ET 200pro Reader Tags


Powered through connection cable
via PROFIBUS
or PROFINET
D100 (6GT2 600-0AD10)
or S7 PLC ET 200pro PROFIBUS DP-V1 Optional: D200 (6GT2 600-1AD00 -0AX0)
Interface Modul A maximum of 2 readers D400 (6GT2 600-4AD00)*
may be connected (RS232)
ET 200pro PROFINET
Interface Modul
+ + + Card holder

D126 (6GT2 600-0AE00)


Connection cable:
D426 (6GT2 600-4AH00)*
2m = 6GT2891-4UH20
ET 200pro PROFINET RF170C D526 (6GT2 600-5AH00)*
CPU module Communication module (do not use an additional 6GT2 890-0CA00

Up to 9 x RF170C
(6GT2002-0HD01) extension cable) RF1040R
Use standard function Connection block (6GT2 831-6CA50)
modules per (6GT2002-1HD01)
block Ident Profile ET 200pro rack Config–Card Company badges
Application example available: (for customer-specific and transponders
https://support.industry.siemens.com/cs/ww/de/view/109770535 reader configuration) acc. ISO 14443 A/B
Incl. MDS E600/E611

6GT2300-0CC00-0AX0
Transponders
acc. ISO 15693

Extension unit IP65


ET 200SP via serial modul RF1070R
(6GT2 831-6BA50)
for operator controls **)

(example; also useful for the connection to other serial modules) (6GT2 831-6BA50-0AX0,
OEM**** )
12’’ 6AV7674-1LA31-0AA0
Company badges
15’’ 6AV7674-1LA41-0AA0 and Transponders
19’’ 6AV7674-1LA51-0AA0 acc. Legic Prime
and Legic Advant
Serial interface RS232 22’’ 6AV7674-1LA61-0AA0

6ES7137-6AA00-0BA0

***)
A maximum of 1 reader per serial module
may be connected (RS232)

+ Connection cable:
3m = 6GT2891-2UH30
+ Company badges
and Transponders
acc. Hitag 1/2/S,
EM41xx, EKS and more
LOGO POWER 220V/5V (do not use an additional
6EP3310-6SB00-0AY0 extension cable)
The max. current of 3 A supplies up to 10 Reader

Use : P2P_Send and P2P_Receive


for programming
Tag restrictions:
* not for RF1070R
** only with RF1070R
**** ATEX not valid for OEM type) *** only with RF1040R

Edition: August 2020 SIMATIC Ident Configuration Guide 49


SIMATIC RF Handhelds
RF350M
Packaged Systems Additional Components Spare Parts

Packaged Systems include Handheld unit,


RFID read/ write head, and battery
Docking/ Spare Battery
6GT2 803-1BA00 Charging Unit 6GT2803-0BM00 6GT2803-0CA00
RF350M suitable for RF200, RF300, MDS E*
internal antenna and MDS D tags,
except for D117, D127, D421, D422 and E623

Packaged Systems Additional Components Spare Parts


Packaged Systems include Handheld unit, Spare Battery
RFID read/ write head, and battery Docking/ Charging Unit 6GT2803-0BM00
6GT2803-0CA00
(Antenna and cable for usage is not included)
External Antenna
6GT2 803-1BA10 Antenna MLFB Suitable for
Needs external antenna without cable
with antenna cable for usage
6GT2398-1CD30-0AX0 D124, D160, D324, D422, D423, D424, D425,
Ant 3 D428, D460, D522, D524, D525, D528, E624,
RF320T, RF330T, RF340T, RF350T, RF360T
suitable for RF200, RF300, MDS E*
and MDS D tags according table in right 6GT2398-1CD50-0AX0 D117, D127, D421, D521
column Ant 3S
6GT2 398-1CF00 D117, D127, D421
Ant 8
6GT2 398-1DC00 D117, D127, D160, D421, D428, D460, D521,
Ant 12 ** D528, E623,
RF350M RF330T

external antenna 6GT2 398-1DA00 D117, D124, D127, D160, D324, D421, D422,
Ant 18 ** D424, D425, D428, D460, D521, D522, D524,
D525, D528, E623, E624
RF320T, RF330T, RF340T

6GT2 398-1DD00 D124, D126, D160, D324, D422, D423, D424,


Ant 30 D425, D426, D428, D460, D522, D524, D525,
D526, D528, E624,
RF320T, RF330T, RF340T, RF350T, RF360T

Antenna cables MLFB Suitable for

0.1 m 6GT2 898-0EA00 For all antenna types above


*) from hardware version AS02: 3m 6GT2 391-0AH30
MDS E and MDS D5xx transponders are supported **) antennas also available with 0.6 m integrated antenna cable;
ANT12 (6GT2398-1CC10), ANT18 (6GT2398-1CA10)

Edition: August 2020 SIMATIC Ident Configuration Guide 50


SIMATIC RF Handhelds

RF600
Packaged Systems Additional Components Spare Parts

Packaged Systems include Handheld unit, Docking/


6GT2 898-0BB00
RFID read/ write head, integrated WLAN and battery Charging Unit

RF650M 6GT2 813-0CA00 (ETSI)

Spare
6GT2 898-0CB00
Battery

6GT2 813-0CA10 (FCC)


RF650M

Edition: August 2020 SIMATIC Ident Configuration Guide 51


SIMATIC Ident Software DVD

SIMATIC Ident Software DVD contains:

• Complete manual set in all available languages


• Includes all manuals for optical identification
• SINEC PNI – Primary Network Initialization
• S7 FBs for STEP 7 and TIA-Portal
• RF200/ RF300/ RF1000 PC Application
• Programming Libraries (APIs)
• Example applications with source code and description
• RFID demo program based on XML for RF600 / RF18xC
• Tag temperature calculation software
• PROFIBUS/ PROFINET GSD/GSDML files
• IO-Link IODD files
• Tool for data throughput calculation
• Documentation archive for legacy products

SIMATIC Ident DVD


6GT2 080-2AA20

Edition: August 2020 SIMATIC Ident Configuration Guide 52


MV420: camera and lens selection
Steps for selecting lens: 1. Define the smallest dot size on DMC code or line width at barcode. Use the horizontal graph next to your size selection in the upper section
2. Define the reading distance and draw a vertical line with a ruler (note: SR-B and SR-P have use the same diagrams)
3. Select a lens and a camera type combination in the upper diagrams which fit best (green bars crossing)
4. Verify at the lower diagrams that the field of view is within the range of your application

Note: For a more detailed selection or if your application is out the presented range ask the presales team at [email protected]

Basic Models: SR-B (6GF3420-0AA20)


or SR-P (6GF3420-0AA40)

MV420, MV440 and MV500: light and filter selection


Lens focal length:
light and Information for selection MV420 MV440 MV500
0.5 mm

filter
Legend: selection
Range for
lens variants 6GF3420-0AC00-1LT0 6GF3440-8DA11; 6GF3540-8DA11
16 mm
Red light The most popular light
6GF3400-0LT01-8DA1 (Basic)
6 mm with a high light intensity (external) 6GF3540-8DA13
10 100 1000 10000 (Multi)
reading distance [mm] 6GF3400-0LT01-8DA1
(external)
Lens focal length:
Dot/line size

White light Use white light if the 6GF3420-0AC00-2LT0 6GF3440-8DA21 6GF3540-8DA23


1 mm

(Multi)
color of the objects
Legend:
Range for varies
lens variants
16 mm Green light For usage with PCB and 6GF3440-8DA31
6 mm
other green materials
10 100 1000 10000
marked with dark codes
reading distance [mm]
Lens focal length: Infrared light No bothersome flashes 6GF3420-0AC00-3LT0 6GF3440-8DA41; 6GF3540-8DA41
6GF3400-0LT01-7BA1 (Basic)
(external) 6GF3400-0LT01-7BA1
2 mm

(external)
Legend:
Range for
Red filter Using red light and red 6GF3540-8AC51
lens variants
6GF3540-8AC52
16 mm filter is improving the
6 mm
image quality
10 100 1000 10000
reading distance [mm] Infrared filter The usage together with 6GF9001-2AD 6GF3540-8AC41
6GF3540-8AC42
1000 infrared light filters
Lens focal
completely the influence
900
length [mm]: of daylight
800 6
Daylight filter For protection of the 6GF3440-8EA1 6GF3540-8AC31
Field of view [mm]

700 6GF3540-8AC32
16 (UVIRcut) camera against laser light
600 beyond the visible
500 spectrum
400 6GF9001-2AF Included in
Polarization Use this filter to reduce
6GF3440-8CX3 Multi-lights
300 filter reflections at metallic or
200 Verify the light shiny parts (i.e. plastic
intensity at
distances
foils)
100 above 400 mm
0
10 100 1000 10000
reading distance

Edition: August 2020 SIMATIC Ident Configuration Guide 53


MV440: camera and lens selection
Steps for selecting lens: 1. Define the smallest dot size on DMC code or line width at barcode. Use the horizontal graphs next to your size selection in the upper section
2. Define the reading distance and draw a vertical line with a ruler at every camera type (SR, HR, UR)
3. Select a lens and a camera type combination in the upper diagrams which fit best (green bar crossing or red bar crossing (intermediate rings (IR) required))
4. Verify at the lower diagrams that the field of view is within the range of your application

Note: For a more detailed selection or if your application is out the presented range ask the presales team at [email protected]

Basic Models: SR (6GF3440-1CD10) HR (6GF3440-1GE10) UR (6GF3440-1LE10)


Lens focal length: Lens focal length: Lens focal length:
75 mm 75 mm 75 mm
50 mm 50 mm 50 mm
0.5 mm

35 mm 35 mm 35 mm
25 mm 25 mm 25 mm
16 mm Legend 16 mm Legend 16 mm Legend
12 mm 12 mm 12 mm
IR 2.5 mm* IR 2.5 mm* IR 2.5 mm*
8,5 mm w/o IR 8,5 mm 8,5 mm
w/o IR w/o IR
6 mm 6 mm 6 mm

10 100 1000 10000 10 100 1000 10000 10 100 1000 10000


reading distance [mm] reading distance [mm] reading distance [mm]
Lens focal length: Lens focal length: Lens focal length:
75 mm 75 mm 75 mm
Dot/line size

50 mm 50 mm 50 mm
35 mm 35 mm 35 mm
1 mm

25 mm 25 mm 25 mm
16 mm Legend 16 mm Legend 16 mm Legend
12 mm 12 mm 12 mm
IR 2.5 mm* IR 2.5 mm* IR 2.5 mm*
8,5 mm 8,5 mm 8,5 mm
w/o IR w/o IR w/o IR
6 mm 6 mm 6 mm

10 100 1000 10000 10 100 1000 10000 10 100 1000 10000


reading distance [mm] reading distance [mm] reading distance [mm]
Lens focal length: Lens focal length: Lens focal length:
75 mm 75 mm 75 mm
50 mm 50 mm 50 mm
35 mm 35 mm 35 mm
2 mm

25 mm 25 mm 25 mm
16 mm Legend 16 mm Legend 16 mm Legend
12 mm 12 mm 12 mm
IR 2.5 mm* IR 2.5 mm* IR 2.5 mm*
8,5 mm w/o IR 8,5 mm w/o IR 8,5 mm w/o IR
6 mm 6 mm 6 mm

10 100 1000 10000 10 100 1000 10000 10 100 1000 10000


reading distance [mm] reading distance [mm] reading distance [mm]

1000 1000 1000


Lens focal Lens focal Lens focal
900 length [mm]: 900 length [mm]: 900 length [mm]:

6 6 6
800 800 800
8,5 8,5 8,5
Field of view [mm]

700 700 700 12


12 12
600 16 600 16 600 16

25 25 25
500 500 500
35 35 35

400 50 400 50 400 50


75 75 75
300 300 300

200 200 200

100 100 100

0 0 0
10 100 1000 10000 10 100 1000 10000 10 100 1000 10000
reading distance reading distance reading distance
*IR = Intermediate rings 6GF9001-1BU required
Edition: August 2020 SIMATIC Ident Configuration Guide 54
MV540 & MV550: camera and lens selection
Steps for selecting lens: 1. Define the smallest dot size on DMC code or line width at barcode. Use the horizontal graphs next to your size selection in the upper section
2. Define the reading distance and draw a vertical line with a ruler at every camera type (S, H)
3. Select a lens and a camera type combination in the upper diagrams which fit best (green bar crossing or red bar crossing (intermediate rings (IR) required))
4. Verify at the lower diagrams that the field of view is within the range of your application

Note: For a more detailed selection or if your application is out the presented range ask the presales team at [email protected]

Basic Models: S (6GF3540-0CD10) H (6GF3540-0GE10)


Lens focal length: Lens focal length:
75 mm 75 mm
50 mm 50 mm
0.5 mm

35 mm 35 mm
25 mm 25 mm
16 mm Legend 16 mm Legend
12 mm 12 mm
IR 2.5 mm* IR 2.5 mm*
8,5 mm 8,5 mm
w/o IR w/o IR
6 mm 6 mm

10 100 1000 10000 10 100 1000 10000


reading distance [mm] reading distance [mm]
Lens focal length: Lens focal length:
75 mm 75 mm
Dot/line size

50 mm 50 mm
35 mm 35 mm
1 mm

25 mm 25 mm
16 mm Legend 16 mm Legend
12 mm 12 mm
IR 2.5 mm* IR 2.5 mm*
8,5 mm 8,5 mm
w/o IR w/o IR
6 mm 6 mm

10 100 1000 10000 10 100 1000 10000


reading distance [mm] reading distance [mm]
Lens focal length: Lens focal length:
75 mm 75 mm
50 mm 50 mm
35 mm 35 mm
2 mm

25 mm 25 mm
16 mm Legend 16 mm Legend
12 mm 12 mm
IR 2.5 mm* IR 2.5 mm*
8,5 mm 8,5 mm
w/o IR w/o IR
6 mm 6 mm

10 100 1000 10000 10 100 1000 10000


reading distance [mm] reading distance [mm]

1000 1000

900 900
Lens focal Lens focal
length [mm]: length [mm]:
800 800
6 6
Field of view [mm]

700 700 8,5


8,5

600 12 600 12
16 16
500 500
25 25

400 35 400 35
50 50
300 300
75 75

200 200

100 100

0 0
10 100 1000 10000 10 100 1000 10000
reading distance reading distance
Also valid for E-Focus lens
*IR = Intermediate rings 6GF9001-1BU required
Edition: August 2020 SIMATIC Ident Configuration Guide 55
MV560: camera and lens selection
Steps for selecting lens: 1. Define the smallest dot size on DMC code or line width at barcode. Use the horizontal graphs next to your size selection in the upper section
2. Define the reading distance and draw a vertical line with a ruler at every camera type (U, X)
3. Select a lens and a camera type combination in the upper diagrams which fit best (green bar crossing or red bar crossing (intermediate rings (IR) required))
4. Verify at the lower diagrams that the field of view is within the range of your application

Note: For a more detailed selection or if your application is out the presented range ask the presales team at [email protected]

Basic Models: U (6GF3560-0LE10) X (6GF3560-0HE10)


Lens focal length: Lens focal length:
75 mm 75 mm
50 mm 50 mm
0.5 mm

35 mm 35 mm
25 mm 25 mm
16 mm Legend 16 mm Legend
Legend
12 mm IR 2.5
IRmm*
12 mm IR 2.5 mm* 2.5 mm*
8,5 mm w/o IR 8,5 mm w/o IR
w/o IR
6 mm 6 mm

10 100 1000 10000 10 100 1000 10000


reading distance [mm] reading distance [mm]
Lens focal length: Lens focal length:
75 mm
75 mm 75 mm
Dot/line size

50 mm
50 mm 50 mm
35 mm
35 mm 35 mm
1 mm

25 mm
25 mm 25 mm
16 mm
16 mm Legend 16 mm Legend
Legend Legend
12 mm
12 mm IR 2.5 mm* 12 mm IR 2.5
IR 2.5 mm* IR mm*
2.5 mm*
8,5 mm
8,5 mm w/o IR 8,5 mm w/o w/o
IR IR
w/o IR
6 mm 6 mm

10 100 1000 10000 10 100 1000 10000


reading distance [mm] reading distance [mm]
Lens focal length: Lens focal length:
75
75 mm
mm 75 mm
50
50 mm
mm 50 mm
35
35 mm
mm 35 mm
2 mm

25
25 mm
mm 25 mm
16
16 mm
mm Legend 16 mm Legend
Legend Legend
12
12 mm
mm IR 2.5 mm* 12 mm IR 2.5 mm*
IR 2.5 mm* IR 2.5 mm*
8,5
8,5 mm
mm w/o IR 8,5 mm w/o IR
w/o IR w/o IR
6 mm 6 mm

10 100 1000 10000 10 100 1000 10000


reading distance [mm] reading distance [mm]

1000
1000 1000
1000

900 900
Lens
Lensfocal
focal Lens focal
Lens focal
length [mm]:
length [mm]: length [mm]:
800 800 800
800 length [mm]:
6
16 6
35
Field of view [mm]

700 700 8,5


8,5
25
600
600 12
35
600
600 12 50
16 16
500 50 500
25 25 75
400
400 75
35
400
400 35
50 50
300 300
75
200 75
200
200 200

100 100
0 0
0 0
10
10
100
100
1000
1000
10000
10000 1010 100
100 1000
1000 10000
10000
reading distance reading distance
Also valid for E-Focus lens
*IR = Intermediate rings 6GF9001-1BU required
Edition: August 2020 SIMATIC Ident Configuration Guide 56
MV420 System Interfaces
Ethernet TCP/IP Reader Options
+ Direct connection
MV420 Ethernet Connection Cable
length from 2 to 15 m available; e.g. 2 m = 6XV1871-5TH20 (no switch required)
+ With external power supply
DI/DO
Wires included in
power supply
Network Connection via Switch cable Open wires

Use native TCP/IP


+ length from 0.5 to 50 m available
e.g. 2 m = 6XV1870-3QH20 + + MV420 Ethernet Connection Cable
length from 2 to 15 m available
+
with text based IP 20: IE switch SCALANCE X (6GK5 …) e.g. 2 m = 6XV1871-5TH20
MV420 complete
commands
or 6 mm lens, red light, 640 x 480 pixel
SR-B: up to 40 reads per second
MV420 Ethernet Connection Cable
IP 67: IE switch SCALANCE X208PRO length form 0.3 m to15 m available
(6GF3420-0AA20)
(6GK5208-0HA10-2AA6) SR-P: up to 70 reads per second
e.g. 2 m = 6XV1870-8AH20 (6GF3420-0AA40)

S7-1200 via Industrial Ethernet or PROFINET

+ Direct connection (1 reader may be connected)


MV420 Ethernet Connection Cable
length from 2 to 15 m available; e.g. 2 m = 6XV1871-5TH20 (no switch required)
+ Optional

Network Connection via Compact Switch Module Lens


6 mm Support

+ + + A maximum of 3 readers may be connected)


+
(6GF3420-0AC00-0LK0)
S7-1200 CPU length from
16 mm Mounting bracket
0.5 to 50 m available
e.g. 2 m = 6XV1870-3QH20 MV420 Ethernet Connection Cable (6GF3420-0AC00-1LK0) 6GF3420-0AC00-1AA0
length from 2 to 15 m available
CSM 1277 e.g. 2 m = 6XV1871-5TH20
(6GK7 277-1AA10-0AA0)
Use library “Ident Profile”

Lights
red

S7-300/1500 via Industrial Ethernet or PROFINET (6GF3420-0AC00-1LT0)


infrared
(6GF3420-0AC00-3LT0)

+ +
Direct connection (1 reader may be connected)
MV420 Ethernet Connection Cable
length from 2 to 15 m available; e.g. 2 m = 6XV1871-5TH20 (no switch required) Cable for
power supply
S7-1500 CPU Network Connection via Compact Switch Module
Open wires
or

+ + + +
S7-300 CPU length from
A maximum of 3 readers may be connected 10 m = 6GF3440-8BA2
30 m = 6GF3440-8BA4
or 0.5 to 50 m available
S7-300 with CP343-1 e.g. 2 m = 6XV1870-3QH20 MV420 Ethernet Connection Cable or Push Pull
length from 2 to 15 m available
1.5 m = 6GF3400-0BH15
e.g. 2 m = 6XV1871-5TH20
Use library “Ident Profile” CSM 377 2 m = 6GF3400-1BH20
(6GK7 377-1AA00-0AA0)

Edition: August 2020 SIMATIC Ident Configuration Guide 57


MV420 System Interfaces

SIMATIC PLC Reader Options


+ +
A maximum of 1 reader may be connected powered through connection cable
S7-1200 DI/DO
RF120C to MV420

RF120C
2 m = 6GT2 091-4LH20
5 m = 6GT2 091-4LH50
10m = 6GT2 091-4LN10 + adapting cable:
2 m = 6GF3420-0AC00-2CB0
Use cable „Power
supply DIO
RS232“ +
And extension cables:
6GT2 002-0LA00 2 m = 6GT2 891-4FH20 5 m = 6GT2 891-4FH50 distribution frame
10 m = 6GT2 891-4FN10 20 m = 6GT2 891-4FN20 instead of
50 m = 6GT2 891-4FN50
adapting cable
MV420 complete 10 m = 6GF3440-8BA2
SIMATIC PLC 6 mm lens, red light, 640 x 480 pixel
SR-B: up to 40 reads per second
30 m = 6GF3440-8BA4
(6GF3420-0AA20)
S7-300 Rack or
+ + +
A maximum of 2 readers may be connected SR-P: up to 70 reads per second
(6GF3420-0AA40)
ASM 475 to MV420
S7-400 via ET 200M Web Interface

(DP-V1/PN-IO)
2 m = 6GT2 891-4EH20
5 m = 6GT2 891-4EH50
And extension cables:
+ adapting cable:
2 m = 6GF3420-0AC00-2CB0 Use additional IE
cable
ASM 475 + Front connector 2 m = 6GT2 891-4FH20 5 m = 6GT2 891-4FH50
Various lengths available
(6GT2 002-0GA10) + (6ES7 392-1AJ00-0AA0) 10 m = 6GT2 891-4FN10 20 m = 6GT2 891-4FN20
2 m = 6XV1871-5TH20
50 m = 6GT2 891-4FN50 Optional
Accessories:
Connecting element (6ES7 390-5AA00-0AA0)
Terminal element (6ES7 390-5BA00-0AA0)

ET 200pro ET 200pro PROFIBUS DP-V1


Lens
6 mm Support
(6GF3420-0AC00-0LK0)
via PROFIBUS Interface module 16 mm
(6GF3420-0AC00-1LK0)
Mounting bracket
6GF3420-0AC00-1AA0
or PROFINET
+ + +
ET 200pro PROFINET A maximum of 2 readers may be connected
Interface module
or S7 PLC RF170C to MV420
ET 200pro PROFINET
CPU module RF170C
Communication module
Extension cables:
2 m = 6GT2 891-4FH20
5 m = 6GT2 891-4FH50
10 m = 6GT2 891-4FN10
+ adapting cable:
2 m = 6GF3420-0AC00-2CB Lights
red
Up to 9 x 170C (6GT2002-0HD01) (6GF3420-0AC00-1LT0)
20 m = 6GT2 891-4FN20 infrared
modules per Connection block 50 m = 6GT2 891-4FN50
(6GT2002-1HD01) (6GF3420-0AC00-3LT0)
ET 200pro rack

PROFIBUS

+
A maximum of 2 readers may be connected
RF166C to MV420

RF166C (DP-V1)
Extension cables:
2 m = 6GT2 891-4FH20
5 m = 6GT2 891-4FH50
10 m = 6GT2 891-4FN10
+ adapting cable:
2 m = 6GF3420-0AC00-2CB0

Communication Module
(6GT2 002-0EE20) 20 m = 6GT2 891-4FN20
50 m = 6GT2 891-4FN50

Edition: August 2020 SIMATIC Ident Configuration Guide 58


MV420 System Interfaces
PROFINET & OPC UA & Ethernet/IP & TCP/IP Reader
powered through connection cable
Options
Communication Modules DI/DO
A maximum of
1 reader at RF185C, Use cable „Power
2 readers at RF186C/CI, supply DIO
4 readers at RF188C/CI RS232“ +
of MV420 may be connected distribution frame
RF185C RF186C RF188C
+ + instead of

+
(6GT2 002-0JE10) (6GT2 002-0JE20) (6GT2 002-0JE40)
Extension cables: adapting cable: adapting cable
2 m = 6GT2 891-4FH20 2 m = 6GF3420-0AC00-2CB0
5 m = 6GT2 891-4FH50 MV420 complete 10 m = 6GF3440-8BA2

Additional IOs 10 m = 6GT2 891-4FN10


20 m = 6GT2 891-4FN20
6 mm lens, red light, 640 x 480 pixel
SR-B: up to 40 reads per second
30 m = 6GF3440-8BA4
50 m = 6GT2 891-4FN50 (6GF3420-0AA20)
SR-P: up to 70 reads per second
(6GF3420-0AA40)
Web Interface
Types of IO-Link

RF186CI RF188CI
+ RF18xCI to sensor + IO module
IO-extension module
Use additional IE
cable
(6GT2 002-0JE50) (6GT2 002-0JE60) 6ES7 14….. (up to 8xDI + 8xDO) Various lengths available
five wire sensor cable from
0.5 to 15 m available 2 m = 6XV1871-5TH20
See page 76 for detailed information
Optional
(e.g. 2 m = 6XV1801-2CH20)

Or one
Standard sensor Lens
6 mm Support
Or one (6GF3420-0AC00-0LK0)
16 mm Mounting bracket
Actor (6GF3420-0AC00-1LK0) 6GF3420-0AC00-1AA0

Lights
red
(6GF3420-0AC00-1LT0)
infrared
(6GF3420-0AC00-3LT0)

Edition: August 2020 SIMATIC Ident Configuration Guide 59


MV420 System Interfaces

Serial RS232 Reader Options


With external power supply
DI/DO
RS232
Terminal RS232 Wires included in

+
box / 1 Reader per COM port may be connected RS232 / power
DI/DO
switching supply cable
RS 232 cable for MV420 (open wires)
cabinet Open wires
24VDC OUT 10 m = 6GF3440-8BA2
30 m = 6GF3440-8BA4

Simple text based 24VDC IN DI/DO (opt.) MV420 complete


protocol 6 mm lens, red light, 640 x 480 pixel
SR-B: up to 40 reads per second
(6GF3420-0AA20)
SR-P: up to 70 reads per second
(6GF3420-0AA40)
Web Interface
Use additional IE
cable
Various lengths available
2 m = 6XV1871-5TH20
Optional

Lens
6 mm Support
(6GF3420-0AC00-0LK0)
16 mm Mounting bracket
(6GF3420-0AC00-1LK0) 6GF3420-0AC00-1AA0

Lights
red
(6GF3420-0AC00-1LT0)
infrared
(6GF3420-0AC00-3LT0)

Edition: August 2020 SIMATIC Ident Configuration Guide 60


MV440 System Interfaces
Ethernet TCP/IP Reader Options
+ Direct connection
MV440 Ethernet Connection Cable
length from 2 to 15 m available; e.g. 2 m = 6XV1871-5TH20 (no switch required)
+ With external power supply
DI/DO *)
Wires included in
power supply cable
Network Connection via Switch Lens „Open wires“

+
6 mm

Use native TCP/IP


with text based
+ + + MV440 Ethernet Connection Cable
length from 2 to 15 m available
(6GF9001-1BB01)
8.5 mm **)
(6GF9001-1BE01)
Software
Text-Genius
commands IP 20: IE switch SCALANCE X (6GK5 …) e.g. 2 m = 6XV1871-5TH20 12 mm
(6GF9001-1BL01)
6GF3400-0SL01
Text-Genius Plus
or 16 mm
6GF3400-1SL01
MV440 Ethernet Connection Cable (6GF9001-1BF01
Veri-Genius
IP 65: IE switch SCALANCE XP208 length form 0.3 m to15 m available MV440 25 mm
6GF3400-0SL02
(6GK5208-0HA00-2AS6) (6GF9001-1BG01)
e.g. 2 m = 6XV1870-8AH20 SR; 640 x 480 pixel: Pat-Genius
35 mm
(6GF3440-1CD10) 6GF3400-0SL03
(6GF9001-1BH01)
HR; 1024 x 768 pixel:
50 mm
(6GF3440-1GE10)

S7-1200 via Industrial Ethernet or PROFINET


(6GF9001-1BJ01)
UR; 1600 x 1200 pixel:
75 mm **) ***)
(6GF3440-1LE10)
(6GF9001-1BK01)
Support

+ Direct connection (1 reader may be connected)


MV440 Ethernet Connection Cable
length from 2 to 15 m available; e.g. 2 m = 6XV1871-5TH20 (no switch required)
+ Cable for
Mounting plate
6GF3440-8CA
Tri-plate
6GF9002-7AD
Lights build-in
power supply red
Network Connection via Compact Switch Module (6GF3440-8DA11) Opt. for Lens
Open wires
white rings

+ + + +
(6GF3440-8DA21)
S7-1200 CPU length from A maximum of 3 readers may be connected) 10 m = 6GF3440-8BA2 green 0.5, 1, 5, 10, 20, 40 mm
0.5 to 50 m available (6GF3440-8DA31) 6GF9001-1BU
30 m = 6GF3440-8BA4
e.g. 2 m = 6XV1870-3QH20 MV440 Ethernet Connection Cable infrared 0.5, 1 mm
length from 2 to 15 m available or Push Pull (6GF3440-8DA41) 6GF9001-1BU01
CSM 1277 e.g. 2 m = 6XV1871-5TH20 length doubler
(6GK7 277-1AA10-0AA0) 1.5 m = 6GF3400-0BH15
Use library “Ident Profile” 6GF9001-1BV
2 m = 6GF3400-1BH20
Filter
Or infrared
Wide-Range Lights external *) 6GF9001-2AD
S7-300/1500 via Industrial Ethernet or PROFINET power supply
red
(6GF3400-0LT01-8DA1)
polarization
6GF9001-2AF
infrared 6GF3440-8CX3

+ +
Direct connection (1 reader may be connected) EU connector (6GF3400-0LT01-7BA1) daylight

MV440 Ethernet Connection Cable


length from 2 to 15 m available; e.g. 2 m = 6XV1871-5TH20 (no switch required)
6GT2 898-0AA00
UK connector
+
Cable adapter M16/M12
6GF3440-8EA1

6GT2 898-0AA10 (6GF3440-8BD1)


Or
Network Connection via Compact Switch Module US connector Cable M12/open wire
S7-1500 CPU (6GF3440-8BC4)
Protective
6GT2 898-0AA20
or
+ lens cover

+ + + +
S7-300 CPU length from
A maximum of 3 readers may be connected metal glas
or 0.5 to 50 m available 5 m cable for 24 V Mounting plate
6GF3440-8AC11
S7-300 with CP343-1 MV440 Ethernet Connection Cable (6GF3440-8CD01)
e.g. 2 m = 6XV1870-3QH20 6GT2 891-0PH50
length from 2 to 15 m available metal plastic
e.g. 2 m = 6XV1871-5TH20 6GF3440-8AC21
Use library “Ident Profile” CSM 377 *) Additional power supply needed
plastic (included in
(6GK7 377-1AA00-0AA0) **) not in combination with build-in lights;
basic model)
***) for protection order additional the tube
6GF3440-8AC12
extension 6GF3440-8AC13

Edition: August 2020 SIMATIC Ident Configuration Guide 61


MV440 System Interfaces
Ethernet TCP/IP or PROFINET (PoE) Reader Options
With power supply over Ethernet (PoE)
DI/DO *)
„Power supply
DIO RS232“
Network Connection via SCALANCE Switches PoE
Lens 10 m = 6GF3440-8BA2
IP20 6 mm 30 m = 6GF3440-8BA4
PC (6GF9001-1BB01)
8.5 mm **) Software
Use native TCP/IP with (6GF9001-1BE01)

+ + + +
Text-Genius
text based commands length from 12 mm
6GF3400-0SL01
0.5 to 50 m available (6GF9001-1BL01)
Text-Genius Plus
e.g. 2 m = 6XV1870-3QH20 MV440 Ethernet Connection Cable 16 mm
6GF3400-1SL01
length from 2 to 15 m available (6GF9001-1BF01
Veri-Genius
IE switch SCALANCE X108 PoE e.g. 2 m = 6XV1871-5TH20 25 mm
6GF3400-0SL02
(6GK5108-0PA00-2AA3) (6GF9001-1BG01)
Pat-Genius
35 mm
6GF3400-0SL03
or (6GF9001-1BH01)
50 mm
S7-1200 CPU (6GF9001-1BJ01)
75 mm **) ***)
Use library “Ident Profile” (6GF9001-1BK01)
Support
Mounting plate
IE switch SCALANCE X308-2M PoE 6GF3440-8CA
(6GK5308-2QG00-2AA2) Tri-plate
6GF9002-7AD
or Lights build-in
red
(6GF3440-8DA11) Opt. for Lens
MV440 white rings
S7-1500 CPU IE switch SCALANCE XR324-4M PoE SR; 640 x 480 pixel: (6GF3440-8DA21)
(e.g. 6GK5324-4QG00-3AR2) green 0.5, 1, 5, 10, 20, 40 mm
or (6GF3440-1CD10) 6GF9001-1BU
HR; 1024 x 768 pixel: (6GF3440-8DA31)
S7-300 CPU infrared 0.5, 1 mm
or (6GF3440-1GE10) 6GF9001-1BU01
UR; 1600 x 1200 pixel: (6GF3440-8DA41)
S7-300 with CP343-1 IP65 length doubler
(6GF3440-1LE10) 6GF9001-1BV
or
Use library “Ident Profile”
Filter
infrared

+ +
Lights external *) 6GF9001-2AD
red polarization
(6GF3400-0LT01-8DA1) 6GF9001-2AF
MV440 Ethernet Connection Cable infrared 6GF3440-8CX3
length form 0.3 m to15 m available (6GF3400-0LT01-7BA1) daylight
IE switch SCALANCE XP208 PoE EEC
(6GK5208-0UA00-5ES6)

or
e.g. 2 m = 6XV1870-8AH20
+
Cable adapter M16/M12
6GF3440-8EA1

(6GF3440-8BD1)
Or
Cable M12/open wire
(6GF3440-8BC4)
Protective

+
Mounting plate
lens cover
metal glas
6GF3440-8AC11
(6GF3440-8CD01)
IE switch SCALANCE XP216 PoE EEC metal plastic
(6GK5216-0UA00-5ES6) 6GF3440-8AC21
*) Additional power supply needed
plastic (included in
**) not in combination with build-in lights;
basic model)
***) for protection order additional the tube
6GF3440-8AC12
extension 6GF3440-8AC13

Edition: August 2020 SIMATIC Ident Configuration Guide 62


MV440 System Interfaces

SIMATIC PLC Reader Options


+ +
A maximum of 1 reader may be connected
powered through connection cable
S7-1200 RF120C to MV440 DI/DO *)
2 m = 6GT2 091-4LH20 5 m = 6GT2 091-4LH50
10m = 6GT2 091-4LN10 „Power supply
And extension cables:
DIO RS232“
RF120C
2 m = 6GT2 891-4FH20 5 m = 6GT2 891-4FH50 Lens 10 m = 6GF3440-8BA2
10 m = 6GT2 891-4FN10 20 m = 6GT2 891-4FN20 6 mm 30 m = 6GF3440-8BA4
6GT2 002-0LA00 50 m = 6GT2 891-4FN50 (6GF9001-1BB01) Software
Reader connector 90° angled 8.5 mm **)
2 m = 6GT2 891-4JH20 5 m = 6GT2 891-4JH50 (6GF9001-1BE01) Text-Genius
10 m = 6GT2 891-4JN10 12 mm 6GF3400-0SL01
(6GF9001-1BL01) Text-Genius Plus

SIMATIC PLC 16 mm
(6GF9001-1BF01
6GF3400-1SL01
Veri-Genius
25 mm 6GF3400-0SL02
S7-300 Rack or Pat-Genius

+ + +
A maximum of 2 readers may be connected (6GF9001-1BG01)
35 mm 6GF3400-0SL03
ASM 475 to MV440
S7-400 via ET 200M 2 m = 6GT2 891-4EH20
(6GF9001-1BH01)
50 mm
Web Interface
Use additional IE cable
(6GF9001-1BJ01)
(DP-V1/PN-IO) 5 m = 6GT2 891-4EH50
75 mm **) ***)
Various lengths available
2 m = 6XV1871-5TH20
And extension cables: (6GF9001-1BK01)
ASM 475 + Front connector 2 m = 6GT2 891-4FH20 5 m = 6GT2 891-4FH50
(6GT2 002-0GA10) + (6ES7 392-1AJ00-0AA0)
Support
10 m = 6GT2 891-4FN10 20 m = 6GT2 891-4FN20
50 m = 6GT2 891-4FN50 Mounting plate
Accessories: Reader connector 90° angled 6GF3440-8CA
Connecting element (6ES7 390-5AA00-0AA0) 2 m = 6GT2 891-4JH20 5 m = 6GT2 891-4JH50 Tri-plate
Terminal element (6ES7 390-5BA00-0AA0) 10 m = 6GT2 891-4JN10 Lights build-in 6GF9002-7AD
red
Opt. for Lens
ET 200pro ET 200pro PROFIBUS DP-V1
MV440
(6GF3440-8DA11)
white
(6GF3440-8DA21)
rings
SR; 640 x 480 pixel:
via PROFIBUS Interface module (6GF3440-1CD10)
HR; 1024 x 768 pixel:
green
(6GF3440-8DA31)
0.5, 1, 5, 10, 20, 40 mm
6GF9001-1BU
0.5, 1 mm
or PROFINET infrared

+ + +
ET 200pro PROFINET A maximum of 2 readers may be connected (6GF3440-1GE10)
(6GF3440-8DA41) 6GF9001-1BU01
UR; 1600 x 1200 pixel: length doubler
Interface module
or S7 PLC RF170C to MV440
2 m = 6GT2 891-4FH20 5 m = 6GT2 891-4FH50
(6GF3440-1LE10) 6GF9001-1BV

ET 200pro PROFINET 10 m = 6GT2 891-4FN10 20 m = 6GT2 891-4FN20 Filter


CPU module RF170C 50 m = 6GT2 891-4FN50 infrared
Communication module Lights external *) 6GF9001-2AD
Up to 9 x 170C (6GT2002-0HD01) Reader connector 90° angled red polarization
modules per Connection block 2 m = 6GT2 891-4JH20 5 m = 6GT2 891-4JH50 (6GF3400-0LT01-8DA1) 6GF9001-2AF
ET 200pro rack (6GT2002-1HD01) 10 m = 6GT2 891-4JN10 infrared 6GF3440-8CX3
(6GF3400-0LT01-7BA1) daylight

PROFIBUS +
Cable adapter M16/M12
6GF3440-8EA1

(6GF3440-8BD1)
Or
Cable M12/open wire

+ +
A maximum of 2 readers may be connected (6GF3440-8BC4) Protective
RF166C to MV440 +
Mounting plate
lens cover
2 m = 6GT2 891-4FH20 5 m = 6GT2 891-4FH50 metal glas
(6GF3440-8CD01) 6GF3440-8AC11
10 m = 6GT2 891-4FN10 20 m = 6GT2 891-4FN20
RF166C (DP-V1) 50 m = 6GT2 891-4FN50 metal plastic
Communication Module *) Additional power supply needed 6GF3440-8AC21
(6GT2 002-0EE20) Reader connector 90° angled **) not in combination with build-in lights;
2 m = 6GT2 891-4JH20 5 m = 6GT2 891-4JH50 plastic (included in
***) for protection order additional the tube basic model)
10 m = 6GT2 891-4JN10 extension 6GF3440-8AC13 6GF3440-8AC12

Edition: August 2020 SIMATIC Ident Configuration Guide 63


MV440 System Interfaces
PROFINET & OPC UA & Ethernet/IP & TCP/IP Reader Options
powered through connection cable
Communication Modules DI/DO *)
A maximum of
1 reader at RF185C, „Power supply
2 readers at RF186C/CI, DIO RS232“
4 readers at RF188C/CI Lens 10 m = 6GF3440-8BA2
6 mm 30 m = 6GF3440-8BA4
of MV440 may be connected

+ +
RF185C RF186C RF188C (6GF9001-1BB01) Software
(6GT2 002-0JE10) (6GT2 002-0JE20) (6GT2 002-0JE40) 8.5 mm **)
2 m = 6GT2 891-4FH20 5 m = 6GT2 891-4FH50 Text-Genius
(6GF9001-1BE01)
10 m = 6GT2 891-4FN10 20 m = 6GT2 891-4FN20 6GF3400-0SL01
12 mm
50 m = 6GT2 891-4FN50 Text-Genius Plus
(6GF9001-1BL01)
Additional IOs Reader connector 90° angled:
16 mm
(6GF9001-1BF01
6GF3400-1SL01
Veri-Genius
2 m = 6GT2 891-4JH20 5 m = 6GT2 891-4JH50
25 mm 6GF3400-0SL02
10 m = 6GT2 891-4JN10
(6GF9001-1BG01) Pat-Genius
35 mm 6GF3400-0SL03
(6GF9001-1BH01)
50 mm Web Interface
Types of IO-Link
+ + (6GF9001-1BJ01) Use additional IE cable
I/O module 75 mm **) ***) Various lengths available
RF186CI RF188CI RF18xCI to sensor IO-extension module (6GF9001-1BK01) 2 m = 6XV1871-5TH20
(6GT2 002-0JE50) (6GT2 002-0JE60)
Sensor cable from 6ES7 14….. (up to 8xDI + 8xDO) Support
0.5 to 15 m available 3SU1400…. (Push Button)
See page 76 for detailed information Mounting plate
(e.g. 2 m = 6XV1801-2CH20)
6GF3440-8CA
Tri-plate
Lights build-in 6GF9002-7AD
red
Or one (6GF3440-8DA11) Opt. for Lens
Standard sensor MV440 white rings
SR; 640 x 480 pixel: (6GF3440-8DA21)
green 0.5, 1, 5, 10, 20, 40 mm
Or one (6GF3440-1CD10)
(6GF3440-8DA31) 6GF9001-1BU
HR; 1024 x 768 pixel: 0.5, 1 mm
Actor (6GF3440-1GE10) infrared
(6GF3440-8DA41) 6GF9001-1BU01
UR; 1600 x 1200 pixel: length doubler
(6GF3440-1LE10) 6GF9001-1BV

Filter
infrared
Lights external *) 6GF9001-2AD
red polarization
(6GF3400-0LT01-8DA1) 6GF9001-2AF
infrared 6GF3440-8CX3
(6GF3400-0LT01-7BA1) daylight

+
Cable adapter M16/M12
6GF3440-8EA1

(6GF3440-8BD1)
Or
Cable M12/open wire
(6GF3440-8BC4)
Protective
+
Mounting plate
lens cover
metal glas
(6GF3440-8CD01)
6GF3440-8AC11
metal plastic
*) Additional power supply needed 6GF3440-8AC21
**) not in combination with build-in lights; plastic (included in
***) for protection order additional the tube basic model)
extension 6GF3440-8AC13 6GF3440-8AC12

Edition: August 2020 SIMATIC Ident Configuration Guide 64


MV440 System Interfaces

Serial RS232 Reader Options


With external power supply
DI/DO *)
RS232 Wires included in
Terminal RS232
RS232 / power

+
box / 1 Reader per COM port may be connected
DI/DO Lens supply cable
switching
RS 232 cable for MV440 (open wires) 6 mm Open wires
cabinet
24VDC OUT 10 m = 6GF3440-8BA2 (6GF9001-1BB01) Software
30 m = 6GF3440-8BA4 8.5 mm **)
(6GF9001-1BE01) Text-Genius
12 mm 6GF3400-0SL01
Simple text based 24VDC IN DI/DO (opt.) (6GF9001-1BL01) Text-Genius Plus
protocol 16 mm 6GF3400-1SL01
(6GF9001-1BF01 Veri-Genius
25 mm 6GF3400-0SL02
(6GF9001-1BG01) Pat-Genius
35 mm 6GF3400-0SL03
(6GF9001-1BH01)
50 mm Web Interface
(6GF9001-1BJ01) Use additional IE cable
75 mm **) ***) Various lengths available
(6GF9001-1BK01) 2 m = 6XV1871-5TH20

Support
Mounting plate
6GF3440-8CA
Tri-plate
Lights build-in 6GF9002-7AD
red
(6GF3440-8DA11) Opt. for Lens
MV440 white rings
SR; 640 x 480 pixel: (6GF3440-8DA21)
green 0.5, 1, 5, 10, 20, 40 mm
(6GF3440-1CD10) 6GF9001-1BU
HR; 1024 x 768 pixel: (6GF3440-8DA31)
infrared 0.5, 1 mm
(6GF3440-1GE10) 6GF9001-1BU01
UR; 1600 x 1200 pixel: (6GF3440-8DA41)
length doubler
(6GF3440-1LE10) 6GF9001-1BV

Filter
infrared
Lights external *) 6GF9001-2AD
red polarization
(6GF3400-0LT01-8DA1) 6GF9001-2AF
infrared 6GF3440-8CX3
(6GF3400-0LT01-7BA1) daylight

+
Cable adapter M16/M12
6GF3440-8EA1

(6GF3440-8BD1)
Or
Cable M12/open wire
(6GF3440-8BC4)
Protective
+
Mounting plate
lens cover
metal glas
(6GF3440-8CD01)
6GF3440-8AC11
metal plastic
*) Additional power supply needed 6GF3440-8AC21
**) not in combination with build-in lights; plastic (included in
***) for protection order additional the tube basic model)
extension 6GF3440-8AC13 6GF3440-8AC12

Edition: August 2020 SIMATIC Ident Configuration Guide 65


MV500 System Interfaces

Ethernet TCP/IP Reader Options


+ +
Direct connection With external power supply
DO
MV500 Ethernet Connection Cable
length from 2 to 15 m available; e.g. 2 m = 6XV1870-8GH20 + 6GK1901-1BB10-2AA0 ³) Wires included in
(no switch required)
power supply cable
„Open wires“
Network Connection via Switch Manual focus lens

+
6 mm: 6GF9001-1BB01 s)

Use native TCP/IP


with text based
+ + + MV500 Ethernet Connection Cable
length from 0.3 to 15 m available MV540
8.5 mm:
12 mm:
12 mm:
6GF9001-1BE01
6GF9001-1BL01
6GF3560-8EA01-0FF0
sh) 1)
sh)
ux) 1) 4)
Micro SD Card
for Configuration
commands IP 20: IE switch SCALANCE X (6GK5 …) e.g. 2 m 6XV1870-8GH20 + 6GK1901-1BB10-2AA0 ³) S; 800 x 600 pixel: 16 mm:
16 mm:
6GF9001-1BF01
6GF3560-8EA02-0FF0
sh)
ux) 1) 4)
Backup; 4GB
(6GF3540-0CD10) 6GK6000-8HT01-0SA2
or H; 1280 x 1024 pixel: 25 mm: 6GF9001-1BG01 sh)

(6GF3540-0GE10) 25 mm: 6GF3560-8EA03-0FF0 ux) 1) 4)


MV500 Ethernet Connection Cable
IP 65: IE switch SCALANCE XP208 length form 0.3 m to15 m available
35 mm: 6GF9001-1BH01 shux) Support
(6GK5208-0HA00-2AS6) MV550 50 mm: 6GF9001-1BJ01 shux)
e.g. 2 m = 6XV1870-8GH20 Mounting plate
S; 800 x 600 pixel: 75 mm: 6GF9001-1BK01 shux) ²)
6GF3440-8CA
(6GF3550-0CD10)
Tri-plate
H; 1280 x 1024 pixel:
6GF9002-7AD
(6GF3550-0GE10)
S7-1200 via Industrial Ethernet or PROFINET MV560
E-Focus lens Opt. for Lens;
U; 1920 x 1200 pixel:
12 mm: 6GF3540-8EA01-0LL0 sh) Rings

+ +
(6GF3560-0LE10)
Direct connection (1 reader may be connected) X; 2592 x 2048 pixel: 16 mm: 6GF3540-8EA02-0LL0 shu)
25 mm: 6GF3540-8EA03-0LL0 shux) 0.5, 1, 5, 10, 20, 40 mm
MV500 Ethernet Connection Cable (6GF3560-0HE10)
6GF9001-1BU
length from 0.3 to 15 m available; e.g. 2 m = 6XV1870-8GH20 + 6GK1901-1BB10-2AA0 ³) 35 mm: 6GF3540-8EA04-0LL0 shux)
(no switch required) 50 mm: 6GF3540-8EA05-0LL0 shux) ²)
0.5, 1 mm
6GF9001-1BU01
Network Connection via Compact Switch Module Cable for length doubler
power supply
+ + + +
6GF9001-1BV
S7-1200 CPU length from A maximum of 3 readers may be connected)
0.5 to 50 m available Open wires
e.g. 2 m = 6XV1870-3QH20 MV500 Ethernet Connection Cable 10 m = 6GF3500-8BA21
Lights build-in
length from 0.3 to 15 m available 30 m = 6GF3500-8BA41
CSM 1277 e.g. 2 m = 6XV1870-8GH20 + 6GK1901-1BB10-2AA0 ³)
red basic: 6GF3540-8DA11
Use library “Ident Profile” (6GK7 277-1AA10-0AA0)
or red multi:
white multi:
6GF3540-8DA13
6GF3540-8DA33
infrared basic: 6GF3540-8DA41
Power supply
EU connector
S7-300/1500 via Industrial Ethernet or PROFINET 6GT2 898-0AA00 Protective lens
UK connector cover

+ +
Direct connection (1 reader may be connected) 6GT2 898-0AA10 Basic length glas
Lights external no filter 6GF3540-8AC11
MV500 Ethernet Connection Cable US connector Red: 6GF3400-0LT01-8DA1 red 6GF3540-8AC51
length from 0.3 to 15 m available; e.g. 2 m = 6XV1870-8GH20 + 6GK1901-1BB10-2AA0 ³) Infrared: 6GF3400-0LT01-7BA1 infrared 6GF3540-8AC41
6GT2 898-0AA20
(no switch required) +
adapter M12/M12
IRUVcut 6GF3540-8AC31
cable for 24 V (6GF3500-8BD10) Long version glas ²)
Network Connection via Compact Switch Module 5 m = 6GT2 891-0PH50
S7-1500 CPU
+ +
Mounting plate
no filter 6GF3540-8AC12
red 6GF3540-8AC52
or

+
50 cm = 6GF3500-8BA11

+ + +
A maximum of 3 readers may be connected (6GF3440-8CD01) infrared 6GF3540-8AC42
S7-300 CPU length from 5 m = 6GF3500-8BA12 IRUVcut 6GF3540-8AC32
or 0.5 to 50 m available
S7-300 with CP343-1 e.g. 2 m = 6XV1870-3QH20 MV500 Ethernet Connection Cable 1) Basic length PMMA
length from 0.3 to 15 m available not in combination with build-in lights;
²) use long version of protective lens cover always and only 6GF3540-8AC21
e.g. 2 m = 6XV1870-8GH20 + 6GK1901-1BB10-2AA0 ³)
Use library “Ident Profile” CSM 377 with 6GF9001-1BK01 and 6GF3540-8EA05-0LL0
(6GK7 377-1AA00-0AA0) 4) No usage of option „Micro SD Card“ with these lens Long version PMMA ²)
shux) indicates the types of camera which are allowed for usage; 6GF3540-8AC22
³) Custom assembly necessary; use the correct stripping tool
i.e. u) means MV5x0U is allowed

Edition: August 2020 SIMATIC Ident Configuration Guide 66


MV500 System Interfaces
Ethernet TCP/IP or PROFINET (PoE): 100MB Reader Options
With power supply over Ethernet (PoE)
DO
Additional cable
for DO-supply is
Network Connection via SCALANCE Switches PoE Manual focus lens needed
6 mm: 6GF9001-1BB01 s) 10 m = 6GF3500-8BA21
PC 8.5 mm: 6GF9001-1BE01 sh) 1) 30 m = 6GF3500-8BA41
12 mm: 6GF9001-1BL01 sh)

+
Use native TCP/IP with MV540
+ + +
12 mm: 6GF3560-8EA01-0FF0 ux) 1) 4)
text based commands length from 16 mm: 6GF9001-1BF01 sh) Micro SD Card
S; 800 x 600 pixel:
0.5 to 50 m available (6GF3540-0CD10) 16 mm: 6GF3560-8EA02-0FF0 ux) 1) 4)
for Configuration
e.g. 2 m = 6XV1870-3QH20 MV500 Ethernet Connection Cable 25 mm: 6GF9001-1BG01 sh)
Backup; 4GB
H; 1280 x 1024 pixel:
length from 0.3 to 15 m available 25 mm: 6GF3560-8EA03-0FF0 ux) 1) 4)
6GK6000-8HT01-0SA2
(6GF3540-0GE10)
IE switch SCALANCE X108 PoE e.g. 2 m = 6XV1870-8GH20 + 6GK1901-1BB10-2AA0 ³) 35 mm: 6GF9001-1BH01 shux)
(6GK5108-0PA00-2AA3) MV550 50 mm: 6GF9001-1BJ01 shux)

or S; 800 x 600 pixel: 75 mm: 6GF9001-1BK01 shux) ²)


(6GF3550-0CD10) Support
S7-1200 CPU
MV500 Ethernet Connection + H; 1280 x 1024 pixel:
(6GF3550-0GE10)

MV560
Mounting plate
6GF3440-8CA
Tri-plate
Use library “Ident Profile” Cable E-Focus lens 6GF9002-7AD
U; 1920 x 1200 pixel:
length from 0.3 to 15 m available 12 mm: 6GF3540-8EA01-0LL0 sh)
(6GF3560-0LE10)
e.g. 2 m = 6XV1870-8GH20 16 mm: 6GF3540-8EA02-0LL0 shu)
X; 2592 x 2048 pixel:
IE switch SCALANCE XP208 PoE EEC (6GF3560-0HE10) 25 mm: 6GF3540-8EA03-0LL0 shux) Opt. for Lens;
(6GK5208-0UA00-5ES6) 35 mm: 6GF3540-8EA04-0LL0 shux) Rings
50 mm: 6GF3540-8EA05-0LL0 shux) ²)
or 0.5, 1, 5, 10, 20, 40 mm

+
6GF9001-1BU

0.5, 1 mm
S7-1500 CPU MV500 Ethernet Connection 6GF9001-1BU01
or Cable
S7-300 CPU length from 0.3 to 15 m available length doubler
e.g. 2 m = 6XV1870-8GH20 Lights build-in 6GF9001-1BV
or
S7-300 with CP343-1 IE switch SCALANCE XP216 PoE EEC red basic: 6GF3540-8DA11
(6GK5216-0UA00-5ES6) red multi: 6GF3540-8DA13
Use library “Ident Profile” white multi: 6GF3540-8DA33
or infrared basic: 6GF3540-8DA41

MV500 Ethernet Connection


+ Protective lens
Cable cover
length from 0.3 to 15 m available
Basic length glas
IE switch SCALANCE X308-2M PoE e.g. 2 m = 6XV1870-8GH20 + 6GK1901-
no filter 6GF3540-8AC11
(6GK5308-2QG00-2AA2) 1BB10-2AA0 ³)
red 6GF3540-8AC51
infrared 6GF3540-8AC41
or IRUVcut 6GF3540-8AC31

IE switch SCALANCE XR324-4M PoE


MV500 Ethernet Connection Cable
+ Long version glas ²)
no filter 6GF3540-8AC12
red 6GF3540-8AC52
length from 0.3 to 15 m available
(e.g. 6GK5324-4QG00-3AR2) e.g. 2 m = 6XV1870-8GH20 + 6GK1901-1BB10-2AA0 ³) infrared 6GF3540-8AC42
IRUVcut 6GF3540-8AC32

1) not in combination with build-in lights; Basic length PMMA


²) use long version of protective lens cover always and only 6GF3540-8AC21
with 6GF9001-1BK01 and 6GF3540-8EA05-0LL0
4) No usage of option „Micro SD Card“ with these lens Long version PMMA ²)
shux) indicates the types of camera which are allowed for usage; 6GF3540-8AC22
³) Custom assembly necessary; use the correct stripping tool
i.e. u) means MV5x0U is allowed

Edition: August 2020 SIMATIC Ident Configuration Guide 67


MV500 System Interfaces
Two parallel Networks on one Device: 1000MB + 100MB Reader Options
1000MB / GigE Network, no PoE needed With power supply over Ethernet (PoE)
DO

+
Direct connection
MV500 Ethernet Connection Cable +
length from 0.3 to 15 m available; e.g. 2 m = 6XV1878-5GH20 + 6GK1901-1BB12-2AA0 ³)
Additional cable
for DO-supply is
(no switch required) Manual focus lens needed
6 mm: 6GF9001-1BB01 s) 10 m = 6GF3500-8BA21
8.5 mm: 6GF9001-1BE01 sh) 1) 30 m = 6GF3500-8BA41
PC Network Connection via Switch 12 mm: 6GF9001-1BL01

+ +
sh)

+
MV550
+
12 mm: 6GF3560-8EA01-0FF0 ux) 1) 4)

Use native TCP/IP with length from 16 mm: 6GF9001-1BF01 sh) Micro SD Card
S; 800 x 600 pixel:
text based commands 0.5 to 50 m available (6GF3550-0CD10) 16 mm: 6GF3560-8EA02-0FF0 ux) 1) 4)
for Configuration
e.g. 2 m = 6XV1870-3QH20 MV500 Ethernet Connection Cable 25 mm: 6GF9001-1BG01 sh)
H; 1280 x 1024 pixel: Backup; 4GB
length from 0.3 to 15 m available
(6GF3550-0GE10) 25 mm: 6GF3560-8EA03-0FF0 ux) 1) 4)
6GK6000-8HT01-0SA2
e.g. 2 m = 6XV1878-5GH20 + 6GK1901-1BB12-2AA0 ³)
35 mm: 6GF9001-1BH01 shux)

IP 20: IE switch SCALANCE X GB (e.g. 6GK5208-0GA00-2AC2) MV560 50 mm: 6GF9001-1BJ01 shux)

U; 1920 x 1200 pixel: 75 mm: 6GF9001-1BK01 shux) ²)


(6GF3560-0LE10) Support

+ MV500 Ethernet Connection


Cable
+ X; 2592 x 2048 pixel:
(6GF3560-0HE10)
Mounting plate
6GF3440-8CA
Tri-plate
E-Focus lens 6GF9002-7AD
length from 0.3 to 15 m available 12 mm: 6GF3540-8EA01-0LL0 sh)
IP 65: IE switch SCALANCE XP216 (e.g. 6GK5216-0HA00-2AS6) e.g. 2 m = 6XV1878-5GH20 16 mm: 6GF3540-8EA02-0LL0 shu)
25 mm: 6GF3540-8EA03-0LL0 shux) Opt. for Lens;
35 mm: 6GF3540-8EA04-0LL0 shux) Rings
50 mm: 6GF3540-8EA05-0LL0 shux) ²)
100 MB / Profinet Network, Switch with PoE 0.5, 1, 5, 10, 20, 40 mm
6GF9001-1BU

Network Connection via SCALANCE Switches PoE 0.5, 1 mm


6GF9001-1BU01

length doubler

PC + length from
0.5 to 50 m available
e.g. 2 m = 6XV1870-3QH20
+ + MV500 Ethernet Connection Cable
length from 0.3 to 15 m available
+ Lights build-in
red basic:
red multi:
6GF3540-8DA11
6GF3540-8DA13
6GF9001-1BV

Use native TCP/IP with white multi: 6GF3540-8DA33


IE switch SCALANCE X108 PoE e.g. 2 m = 6XV1870-8GH20 + 6GK1901-1BB10-2AA0 ³) infrared basic: 6GF3540-8DA41
text based commands
(6GK5108-0PA00-2AA3)
or
IE switch SCALANCE X308-2M PoE Protective lens
(6GK5308-2QG00-2AA2)
cover
or
Basic length glas
S7-1200 CPU IE switch SCALANCE XR324-4M PoE
no filter 6GF3540-8AC11
(e.g. 6GK5324-4QG00-3AR2)
red 6GF3540-8AC51
Use library “Ident Profile”
or infrared 6GF3540-8AC41
IRUVcut 6GF3540-8AC31

MV500 Ethernet Connection + Long version glas ²)


no filter 6GF3540-8AC12
Cable red 6GF3540-8AC52
S7-1500 CPU length from 0.3 to 15 m available infrared 6GF3540-8AC42
or e.g. 2 m = 6XV1870-8GH20 IRUVcut 6GF3540-8AC32
S7-300 CPU IE switch SCALANCE XP208 PoE EEC
(6GK5208-0UA00-5ES6) 1) not in combination with build-in lights; Basic length PMMA
or 6GF3540-8AC21
²) use long version of protective lens cover always and only
S7-300 with CP343-1 or with 6GF9001-1BK01 and 6GF3540-8EA05-0LL0
IE switch SCALANCE XP216 PoE EEC 4) No usage of option „Micro SD Card“ with these lens Long version PMMA ²)
Use library “Ident Profile” (6GK5216-0UA00-5ES6) 6GF3540-8AC22
shux) indicates the types of camera which are allowed for usage;
³) Custom assembly necessary; use the correct stripping tool
i.e. u) means MV5x0U is allowed

Edition: August 2020 SIMATIC Ident Configuration Guide 68


MV500 System Interfaces

SIMATIC PLC Reader Options


+ +
A maximum of 1 reader may be connected
RF120C to MV500 Powered through connection cable
S7-1200 adapting cable:
50 cm = 6GF3500-8BA11 + 2 m = 6GT2 091-4LH20
5 m = 6GT2 091-4LH50
5 m = 6GF3500-8BA12 10m = 6GT2 091-4LN10

And extension cables:


RF120C 2 m = 6GT2 891-4FH20 Manual focus lens
6GT2 002-0LA00 5 m = 6GT2 891-4FH50 6 mm: 6GF9001-1BB01 s)

10 m = 6GT2 891-4FN10 8.5 mm: 6GF9001-1BE01 sh) 1)

20 m = 6GT2 891-4FN20 12 mm: 6GF9001-1BL01 sh)

50 m = 6GT2 891-4FN50 MV540 12 mm: 6GF3560-8EA01-0FF0 ux) 1) 4)


Micro SD Card
S; 800 x 600 pixel: 16 mm: 6GF9001-1BF01 sh)

SIMATIC PLC 16 mm: 6GF3560-8EA02-0FF0 ux) 1) 4)


(6GF3540-0CD10) for Configuration
H; 1280 x 1024 pixel: 25 mm: 6GF9001-1BG01 sh)
Backup; 4GB
(6GF3540-0GE10) 25 mm: 6GF3560-8EA03-0FF0 ux) 1) 4)
6GK6000-8HT01-0SA2

+ + +
A maximum of 2 readers may be connected
S7-300 Rack or 35 mm: 6GF9001-1BH01 shux)

MV550 50 mm: 6GF9001-1BJ01 shux)


ASM 475 to MV500 S; 800 x 600 pixel: 75 mm: 6GF9001-1BK01 shux) ²)
S7-400 via ET 200M adapting cable:
+ 2 m = 6GT2 891-4EH20
(6GF3550-0CD10)
H; 1280 x 1024 pixel:
Support
50 cm = 6GF3500-8BA11 5 m = 6GT2 891-4EH50 Mounting plate
(DP-V1/PN-IO) 5 m = 6GF3500-8BA12 (6GF3550-0GE10)
6GF3440-8CA
ASM 475 + Front connector MV560 Tri-plate
(6GT2 002-0GA10) + (6ES7 392-1AJ00-0AA0) And extension cables: U; 1920 x 1200 pixel: E-Focus lens 6GF9002-7AD
2 m = 6GT2 891-4FH20 (6GF3560-0LE10) 12 mm: 6GF3540-8EA01-0LL0 sh)
Accessories: 5 m = 6GT2 891-4FH50 X; 2592 x 2048 pixel: 16 mm: 6GF3540-8EA02-0LL0 shu)
Connecting element (6ES7 390-5AA00-0AA0) 10 m = 6GT2 891-4FN10 (6GF3560-0HE10) 25 mm: 6GF3540-8EA03-0LL0 shux) Opt. for Lens;
Terminal element (6ES7 390-5BA00-0AA0) 20 m = 6GT2 891-4FN20 35 mm: 6GF3540-8EA04-0LL0 shux) Rings
50 m = 6GT2 891-4FN50 50 mm: 6GF3540-8EA05-0LL0 shux) ²)
0.5, 1, 5, 10, 20, 40 mm
6GF9001-1BU

ET 200pro ET 200pro PROFIBUS DP-V1


Interface module 0.5, 1 mm
6GF9001-1BU01
via PROFIBUS A maximum of 2 readers may be connected

or PROFINET
ET 200pro PROFINET
Interface module + + adapting cable:
+
And extension cables:
Lights build-in
red basic: 6GF3540-8DA11
length doubler
6GF9001-1BV

or S7 PLC ET 200pro PROFINET


50 cm = 6GF3500-8BA11
5 m = 6GF3500-8BA12 (+) 2 m = 6GT2 891-4FH20
5 m = 6GT2 891-4FH50
red multi:
white multi:
6GF3540-8DA13
6GF3540-8DA33
CPU module RF170C 10 m = 6GT2 891-4FN10 infrared basic: 6GF3540-8DA41
Communication module 20 m = 6GT2 891-4FN20
Up to 9 x 170C (6GT2002-0HD01) 50 m = 6GT2 891-4FN50
modules per Connection block
ET 200pro rack (6GT2002-1HD01)
Protective lens
cover
Basic length glas
no filter 6GF3540-8AC11

PROFIBUS red 6GF3540-8AC51


infrared 6GF3540-8AC41

+ +
IRUVcut 6GF3540-8AC31
A maximum of 2 readers may be connected
RF166C to MV500 Long version glas ²)
no filter 6GF3540-8AC12
adapting cable:
(+)
And extension cables: red 6GF3540-8AC52
50 cm = 6GF3500-8BA11 2 m = 6GT2 891-4FH20 infrared 6GF3540-8AC42
5 m = 6GF3500-8BA12 5 m = 6GT2 891-4FH50 IRUVcut 6GF3540-8AC32
10 m = 6GT2 891-4FN10
20 m = 6GT2 891-4FN20 1) Basic length PMMA
not in combination with build-in lights;
RF166C (DP-V1) 50 m = 6GT2 891-4FN50
²) use long version of protective lens cover always and only 6GF3540-8AC21
Communication Module
with 6GF9001-1BK01 and 6GF3540-8EA05-0LL0
(6GT2 002-0EE20) Long version PMMA ²)
4) No usage of option „Micro SD Card“ with these lens
shux) indicates the types of camera which are allowed for usage; 6GF3540-8AC22
i.e. u) means MV5x0U is allowed

Edition: August 2020 SIMATIC Ident Configuration Guide 69


MV500 System Interfaces
PROFINET & Ethernet/IP & OPC UA & TCP/IP Reader Options
Powered through connection cable
Communication Modules
A maximum of
1 reader at RF185C,
2 readers at RF186C/CI,
4 readers at RF188C/CI Manual focus lens
of MV500 may be connected 6 mm: 6GF9001-1BB01 s)

RF185C RF186C RF188C


(6GT2 002-0JE10) (6GT2 002-0JE20) (6GT2 002-0JE40) + adapting cable:
50 cm = 6GF3500-8BA11 (+) And extension cables:
2 m = 6GT2 891-4FH20
+ MV540
8.5 mm:
12 mm:
12 mm:
6GF9001-1BE01
6GF9001-1BL01
6GF3560-8EA01-0FF0
sh) 1)
sh)
ux) 1) 4)
Micro SD Card
5 m = 6GF3500-8BA12 5 m = 6GT2 891-4FH50 S; 800 x 600 pixel: 16 mm: 6GF9001-1BF01 sh)

10 m = 6GT2 891-4FN10 (6GF3540-0CD10) 16 mm: 6GF3560-8EA02-0FF0 ux) 1) 4)


for Configuration
Additional IOs 20 m = 6GT2 891-4FN20 H; 1280 x 1024 pixel: 25 mm: 6GF9001-1BG01 sh)
Backup; 4GB
50 m = 6GT2 891-4FN50 (6GF3540-0GE10) 25 mm: 6GF3560-8EA03-0FF0 ux) 1) 4)
6GK6000-8HT01-0SA2
35 mm: 6GF9001-1BH01 shux)

MV550 50 mm: 6GF9001-1BJ01 shux)

S; 800 x 600 pixel: 75 mm: 6GF9001-1BK01 shux) ²)


(6GF3550-0CD10) Support
H; 1280 x 1024 pixel:
Types of IO-Link
+ +
Mounting plate
(6GF3550-0GE10)
I/O module 6GF3440-8CA
RF186CI RF188CI RF18xCI to sensor IO-extension module MV560 Tri-plate
(6GT2 002-0JE50) (6GT2 002-0JE60) U; 1920 x 1200 pixel: E-Focus lens 6GF9002-7AD
Sensor cable from 6ES7 14….. (up to 8xDI + 8xDO)
(6GF3560-0LE10) 12 mm: 6GF3540-8EA01-0LL0 sh)
0.5 to 15 m available X; 2592 x 2048 pixel: 16 mm: 6GF3540-8EA02-0LL0 shu)
(e.g. 2 m = 6XV1801-2CH20) See page 76 for detailed information
(6GF3560-0HE10) 25 mm: 6GF3540-8EA03-0LL0 shux) Opt. for Lens;
35 mm: 6GF3540-8EA04-0LL0 shux) Rings
50 mm: 6GF3540-8EA05-0LL0 shux) ²)
0.5, 1, 5, 10, 20, 40 mm
Or one 6GF9001-1BU
Standard sensor 0.5, 1 mm
6GF9001-1BU01

length doubler
Or one 6GF9001-1BV
Lights build-in
Actor red basic: 6GF3540-8DA11
red multi: 6GF3540-8DA13
white multi: 6GF3540-8DA33
infrared basic: 6GF3540-8DA41

Protective lens
cover
Basic length glas
Lights external no filter 6GF3540-8AC11
Red: 6GF3400-0LT01-8DA1 red 6GF3540-8AC51
Infrared: 6GF3400-0LT01-7BA1 infrared 6GF3540-8AC41
+
adapter M12/M12
IRUVcut 6GF3540-8AC31

(6GF3500-8BD10) Long version glas ²)


+
Mounting plate
no filter 6GF3540-8AC12
red 6GF3540-8AC52
(6GF3440-8CD01) infrared 6GF3540-8AC42
IRUVcut 6GF3540-8AC32

1) not in combination with build-in lights; Basic length PMMA


²) use long version of protective lens cover always and only 6GF3540-8AC21
with 6GF9001-1BK01 and 6GF3540-8EA05-0LL0
4) No usage of option „Micro SD Card“ with these lens Long version PMMA ²)
shux) indicates the types of camera which are allowed for usage; 6GF3540-8AC22
i.e. u) means MV5x0U is allowed

Edition: August 2020 SIMATIC Ident Configuration Guide 70


MV500 System Interfaces

Serial RS232 Reader Options


With external power supply
DO

RS232 Wires included in


Terminal RS232 power supply cable
1 Reader per COM port may be connected
box /
switching
cabinet
DI/DO

24VDC OUT
RS 232 cable for MV500 (open wires)
10 m = 6GF3500-8BA21
+ 6 mm:
Manual focus lens
6GF9001-1BB01 s)
„Open wires“

8.5 mm: 6GF9001-1BE01 sh) 1)

30 m = 6GF3500-8BA41 12 mm: 6GF9001-1BL01 sh)

MV540 12 mm: 6GF3560-8EA01-0FF0 ux) 1) 4)


Micro SD Card
24VDC IN S; 800 x 600 pixel: 16 mm: 6GF9001-1BF01 sh)
Simple text based DI/DO (opt.)
(6GF3540-0CD10) 16 mm: 6GF3560-8EA02-0FF0 ux) 1) 4)
for Configuration
protocol 25 mm: 6GF9001-1BG01 sh)
Backup; 4GB
H; 1280 x 1024 pixel:
(6GF3540-0GE10) 25 mm: 6GF3560-8EA03-0FF0 ux) 1) 4)
6GK6000-8HT01-0SA2
35 mm: 6GF9001-1BH01 shux)

MV550 50 mm: 6GF9001-1BJ01 shux)

S; 800 x 600 pixel: 75 mm: 6GF9001-1BK01 shux) ²)


(6GF3550-0CD10) Support
H; 1280 x 1024 pixel:
Mounting plate
(6GF3550-0GE10)
6GF3440-8CA
MV560 Tri-plate
U; 1920 x 1200 pixel: E-Focus lens 6GF9002-7AD
(6GF3560-0LE10) 12 mm: 6GF3540-8EA01-0LL0 sh)
X; 2592 x 2048 pixel: 16 mm: 6GF3540-8EA02-0LL0 shu)
(6GF3560-0HE10) 25 mm: 6GF3540-8EA03-0LL0 shux) Opt. for Lens;
35 mm: 6GF3540-8EA04-0LL0 shux) Rings
50 mm: 6GF3540-8EA05-0LL0 shux) ²)
0.5, 1, 5, 10, 20, 40 mm
6GF9001-1BU

0.5, 1 mm
6GF9001-1BU01

length doubler
Lights build-in 6GF9001-1BV
red basic: 6GF3540-8DA11
red multi: 6GF3540-8DA13
white multi: 6GF3540-8DA33
infrared basic: 6GF3540-8DA41

Protective lens
cover
Basic length glas
Lights external no filter 6GF3540-8AC11
Red: 6GF3400-0LT01-8DA1 red 6GF3540-8AC51
Infrared: 6GF3400-0LT01-7BA1 infrared 6GF3540-8AC41
+
adapter M12/M12
IRUVcut 6GF3540-8AC31

(6GF3500-8BD10) Long version glas ²)


+
Mounting plate
no filter 6GF3540-8AC12
red 6GF3540-8AC52
(6GF3440-8CD01) infrared 6GF3540-8AC42
IRUVcut 6GF3540-8AC32

1) not in combination with build-in lights; Basic length PMMA


²) use long version of protective lens cover always and only 6GF3540-8AC21
with 6GF9001-1BK01 and 6GF3540-8EA05-0LL0
4) No usage of option „Micro SD Card“ with these lens Long version PMMA ²)
shux) indicates the types of camera which are allowed for usage; 6GF3540-8AC22
i.e. u) means MV5x0U is allowed

Edition: August 2020 SIMATIC Ident Configuration Guide 71


MV320, MV325 System Interfaces

PC via USB Reader Options


Powered through USB-cable

MV320
(6GF3320-
0HT01)
1 Reader per USB port may be connected
PC
USB cable for MV320/ MV325
The USB-cable (1.8 m) is included in the delivery scope
MV325 with
Docking station
Docking station
(6GF3325-0HT01)
for MV325
(6GF3325-0AC03)
Panel PC

RF170C Reader
Powered through connection cable
ET200pro ET200pro PROFIBUS DP-V1
Interface module Spare Battery
via PROFIBUS for MV325
A maximum of 2 readers may be connected

+
or PROFINET ET200pro PROFINET MV320 (6GF3325-0AC07)
(6GF3320-0HT01)
Interface module RS 232 cable for MV320
or S7 PLC (6GT2191-0BH50)
ET200pro PROFINET RF170C
CPU module Communication module
(6GT2 002-0HD01)
Up to 9 x 170C Connection block
modules per (6GT2 002-1HD01)
ET200pro rack

RS232 Reader Metal stand for


With external power supply MV320
For SIMATIC and other PLC (6GF3320-0AC07)
1 Reader per RS232 port may be connected
MV320
RS 232 cable for MV320 (6GF3320-0HT01)
6GF3320-0AC03

+ power supply
Europe
CM PtP RS 232 BA (6GF3020-0AC40-0AP2)
i.e. S7-1500 CPU
(6ES7540-1AD00-0AA0) US
(6GF3020-0AC40-0AP1)

Edition: August 2020 SIMATIC Ident Configuration Guide 72


MV320, MV325 System Interfaces

PROFINET & Ethernet/IP Reader Options


A maximum of Powered through connection cable
Communication Modules 1 reader at RF185C,
2 readers at RF186C/CI, RF188C/CI

+ of MV300 may be connected


RS 232 cable for MV320
(6GT2191-0BH50)
+
RF185C RF186C RF188C
(6GT2 002-0JE10) (6GT2 002-0JE20) (6GT2 002-0JE40)

Additional IOs

Types of IO-Link
+ RF18xCI to sensor
+ IO module
IO-extension module
RF186CI RF188CI Sensor cable from 6ES7 14….. (up to 8xDI + 8xDO)
(6GT2 002-0JE50) (6GT2 002-0JE60) 0.5 to 15 m available
(e.g. 2 m = 6XV1801-2CH20) See page 76 for detailed information

MV320
Or one (6GF3320-0HT01)
Standard sensor
Or one
Actor
Metal stand for
MV320
(6GF3320-0AC07)

PROFIBUS
A maximum of 2 readers may be connected
+ RS 232 cable for MV320
+
(6GT2191-0BH50)

RF166C (DP-V1)
Communication Module
(6GT2 002-0EE20)

Edition: August 2020 SIMATIC Ident Configuration Guide 73


System Interfaces for general purpose serial devices (RS232 or RS422)

PROFINET & Ethernet/IP Serial device Options


Communication Modules A maximum of powered through connection cable
1 serial device at RF185C,
2 serial devices at RF186C/CI,
4 serial devices at RF188C/CI** Provided power from CM:
may be connected via RS232* or RS422 Always refer to
RF185C RF186C RF188C
(6GT2 002-0JE10) (6GT2 002-0JE20) (6GT2 002-0JE40)
+ Customer assembled cable: CM connector (6GT2090-0BE00)
Bulk cable i.e. 50 m (6GT2 090-4AN50)
+ 24 Volt
up to 800 mA for each device
5 Volt * (only when RS232 is used)
the manual of
the connected
up to 500 mA for each device device
Device connector (Order via distributor)
Additional IOs
Types of IO-Link
+ +
Examples of devices:
I/O module
RF18xCI to sensor IO-extension module
Sensor cable from 6ES7 14….. (up to 8xDI + 8xDO)
RF186CI RF188CI 0.5 to 15 m available
(6GT2 002-0JE50) (6GT2 002-0JE60) (e.g. 2 m = 6XV1801-2CH20) See page 76 for detailed information
Cabling:
Or one
Standard sensor Use a bulk cable (i.e.
i.e. scanners, handheld devices
6GT2090-4AN50) and
Or one assemble left side the
Actor CM connector
6GT2090-0BE00
The right side
PROFIBUS connector you may
order via distributor for
A maximum of 2 readers may be connected
+ +
electronic components

RF166C to serial device via RS232* or RS422 Serial device Or


Customer assembled cable: CM connector (6GT2090-0BE00) powered with external power supply
Bulk cable i.e. 50 m (6GT2 090-4AN50)
Device connector (Order via distributor)
Provided power: Use the cable
RF166C (DP-V1) delivered by th device,
Communication Module Always customer cut the left side
(6GT2 002-0EE20) specific power supply connector and replace
it with a plug
6GT2090-0BE00

RF170C ET200pro PROFIBUS DP-V1


Examples of devices:
Or (only RS422)
Interface module
A maximum of 2 readers may be connected
ET200pro
+ + +
You may use one of
ET200pro PROFINET the standard reader
via PROFIBUS Interface module RF170C to serial device via RS232* or RS422 cable 6GT2891-4F,
cut and replace the
or PROFINET ET200pro PROFINET RF170C
Customer assembled cable: CM connector (6GT2090-0BE00)
Bulk cable i.e. 50 m (6GT2 090-4AN50)
connector on the right
side (device side)
or S7 PLC CPU module Communication module Device connector (Order via distributor)
(6GT2 002-0HD01)
Up to 9 x 170C Connection block
modules per (6GT2 002-1HD01)
ET200pro rack i.e. robots, motors, tooling machines
*) always use short cables (maximum 5 m) when using 5V
power supply from CM
**) on RS232 usage: only 2 serial devices can be connected

Edition: August 2020 SIMATIC Ident Configuration Guide 74


RF18xC /CI Bill of Materials Guide
The RF18xC is a communication module that can connect to Ethernet-based Bus Topology Concept
networks via an M12 d-coded connector. It supports a variety of protocols like RF185C Reader RF186C/CI Reader RF188C/CI Reader
PROFINET, Ethernet/IP, OPC UA, TCP/IP. A integrated switch enables star and
line topologies. The module has L-coded M12 connectors for the 24 V power
supply. The power can be transferred to additional loads at a second L-coded
female connector. The L-coded connectors can transmit a continuous current of
up to 16 A. 24VDC Power
The designer chooses whether to purchase pre-made network cables or to make Covering cap
his/her own. Note that no Termination Resistors are required on end-nodes, but Covering cap
covering caps are highly recommended.
PROFINET

Description Part Number Notes


Description Part Number Notes

RF185C 6GT2 002-0JE10 1 read/write device or reader


Make your own RF18xC to RF reader cables
RF186C 6GT2 002-0JE20 2 read/write devices or readers
RF188C 6GT2 002-0JE40 4 read/write devices or readers Refer to the Bulk cable and connectors tables (Pages 78 - 79)
RF186CI 6GT2 002-0JE50 2 read/write devices or readers plus sensors
RF188CI 6GT2 002-0JE60 4 read/write devices or readers plus sensors Use pre-made RF18xC to RF reader cables
can be connected to PROFINET or Ethernet (OPC UA)
6GT2 891-4FH20 2 meter pre-assembled cable
Make your own M12 PROFINET connection cables
Reader cable R200/ RF300/ MV440 6GT2 891-4FH50 5 meter pre-assembled cable
Ethernet to connection Block. 2 x M12
SIMATIC NET Ethernet M12 4-pin connector 6GK1 901-0DB10-6AA0 or
4-pin connectors needed if loop-through 6GT2 891-4FN10 10 meter pre-assembled cable
Extension cable
RJ45 connector with metal casing and FC For connection into standard RJ45-type Ethernet for RF200/ RF300/ MV400 /MV500
6GK1 901-1BB10-2AA0 6GT2 891-4FN20 20 meter pre-assembled cable
connection system, 180° cable outlet switch
6GT2 891-4FN50 50 meter pre-assembled cable
ETHERNET industrial cable 2x2, Type A, Sold by the meter
6XV1 840-2AH10
unassembled Minimum length 20 m; Maximum length 1000 m Reader cable to RF1000 6GT2891-4UH20 2 meter pre-assembled cable

Use pre-made M12 PROFINET connection cables 5 meter pre-assembled coiled cable with a
Reader cable to MV320 6GT2191-0BH50
usable length between 1.6 and 4 meter
Pre-assembled PROFINET cable with 4-pin
6XV1 870-8xxx* 0.3 m– 15 m pre-assembled cable
M12 on both ends Reader cable MV420 6GF3420-0AC00-2CB0 2 meter pre-assembled cable

Make your own M12 L-coded power supply connection cables 6GF3500-8BA11 0.5 meter pre-assembled cable
Reader cable MV500
6GF3500-8BA12 5 meter pre-assembled cable
Power cable For the supply side of the 24 VDC power,
6XV1801-2B
(4 wire x 1.5 mm2, trailing type) from 20m up to 1000m Additional components

Covering caps for unused M12 ports 3RX9 802-0AA00 1 pack = 10 items
For the supply side of the 24 VDC power,
M12 L-coded – male connector 6GK1906-0EA00
screw joint for wires up to 1.5 mm2
Make your own M12 sensor cable (only RF18xCI variants)

For the loop-through of 24 VDC power, Sensor Connector at CM-side


M12 L-coded – female connector 6GK1906-0EB00 M12 A-coded – male connector, 4 pin 6GK1 907-0DB10-6AA3
screw joint for wires up to 1.5 mm2 for cable diameter 6 – 8 mm

Use pre-made M12 L-coded power supply connection cables Sensor-side connector
M12 A-coded – female connector, 4 pin 6GK1 907-0DC10-6AA3
for cable diameter 6 – 8 mm
Cable for supply voltage with pre-
6XV1801-6Dxxx* Lengths available from 0.5 m up to 15 m Sensor cable five wire 6XV1801-2C bulk cable; minimum order 20 meter
Assembled M12 L-coded connectors 180°

Sensor connector at CM-side


Cable for supply voltage with pre-
6XV1801-6Gxxx* Lengths available from 0.5 m up to 15 m M12 A-coded – male connector, 5 pin, 180° 6GK1 909-0DB10-6AA3 Required for assembling an IO-Link
Assembled M12 L-coded connectors 90° port Class B cable

Cable for supply voltage assembled with Length 5 m


M12 A-coded 4pin male connector and 6GT2091-0PH50 M12 A-coded – female connector, 5 pin, 180° 6GK1 909-0DC10-6AA3 Sensor connector at sensor-side
Useful to connect the CM directly to a power supply of
M12 L-coded connector female at CM side type 6GT2898-0ACx0
Use pre-made M12 sensor cable (only RF18xCI variants)

IO-Link (port Class B) sensor cable with


6XV1801-2Cxxx* Lengths available from 0.5 m up to 15 m
M12 A-coded 5-pin connectors (male and female)

* These cables are available in various lengths (see catalogue or mall)

Edition: August 2020 SIMATIC Ident Configuration Guide 75


RF18xCI Bill of Materials Guide, Sensor Cabling
The RF18xCI variants allow the connecting of a variety of IO-Link I/O modules. A Bus Topology Concept
maximum of 8 sensors (inputs) and 8 actors (outputs) may be connected to one RF186CI Reader RF186CI Reader
CM. There is no additional configuration necessary for the I/Os. The I/Os can be
used with all available protocols: PROFINET, Ethernet/IP, OPC UA and TCP/IP. Sensors,
Sensors, High
actors
Read this page for connecting details. power actors

The designer chooses whether to purchase pre-made sensor cable or to make 24VDC Power
his/her own (see page 75) *)

PROFINET

Description Part Number Notes

RF186CI 6GT2 002-0JE50 2 read/write devices or readers plus sensors


RF188CI 6GT2 002-0JE60 4 read/write devices or readers plus sensors
can be connected to PROFINET or Ethernet (OPC UA)

Sensor/actor cabling I/O modules with M8 senor connectors


+ I/O module to sensor
+
6ES7 141-5BF00-0BL0 (8xDI)***
6ES7 143-5BF00-0BL0 (4xDI + 4xDO)** Use sensor cables from the
3RK5 010-0CA00-0AA0 (8xDI; K20)*** sensor market

+ RF18xCI to IO-Link
+ I/O modules with M12 sensor connectors
6ES7 141-5AH00-0BL0 (8xDI) **
RF186CI
(6GT2 002-0JE50)
I/O module or
sensor, actor
6ES7 143-5AH00-0BL0 (8xDI + 8xDO)**
3RK5 010-0BA10-0AA0 (4xDI; K20)*** + I/O module to sensor
+
0.5 m = 6XV1801-2CE50
1 m = 6XV1801-2CH10 0.5 m = 6XV1801-2CE50
1.5 m = 6XV1801-2CH15 1 m = 6XV1801-2CH10
2 m = 6XV1801-2CH20 1.5 m = 6XV1801-2CH15
3 m = 6XV1801-2CH30 2 m = 6XV1801-2CH20
6ES7 142-5AF00-0BL0 (8xDO, 2A)** 3 m = 6XV1801-2CH30
5 m = 6XV1801-2CH50
Extra M12 L-coded power cable needed *) 5 m = 6XV1801-2CH50
10 m = 6XV1801-2CN10
15 m = 6XV1801-2CN15 10 m = 6XV1801-2CN10
RF188CI 15 m = 6XV1801-2CN15
(6GT2 002-0JE60)

*) Some IO modules for high


output current need an extra L-
coded power cable One standard sensor
6XV1801-6Dxxx from 0.5 to 15 m Or one actor, lamp

**) the new I/O modules are available end 2020


***) K20 are old types of Input modules without picture

Edition: August 2020 SIMATIC Ident Configuration Guide 76


RF166C Bill of Materials Guide
The RF166C is a PROFIBUS DP-V1 interface module. The PROFIBUS connection is made via
M12 B-coded connector.
Bus Topology Concept
The module has L-coded M12 connectors for the 24 V power supply. The power can be RF166C RF166C RF166C
Reader Reader Reader
transferred to additional loads at a second L-coded female connector. The L-coded
connectors can transmit a continuous current of up to 16 A.

The designer chooses whether to purchase pre-made network cables or to make his/her own.
Note that another design consideration is whether the RF166C is a PROFIBUS end-node or
not. If it is an end-node, a Termination Resistor is required. PROFIBUS Bus Termination

Covering cap
24VDC Power

Description Part Number Notes Description Part Number Notes

For PROFIBUS DP-V1 networks. Make your own RF166C to RF reader cables
RF166C 6GT2 002-0EE20 2 read/write devices or readers can be connected
The devices may have RS422 or RS232 interface Refer to the Bulk cable and connectors tables (Pages 78- 79)

Make your own M12 PROFIBUS connection cables Use pre-madeRF166C to RF reader cables

6GT2 891-4FH20 2 meter pre-assembled cable


For the supply side of the PROFIBUS network.
PROFIBUS M12 connector plug
6GK1 905-0EB00 Use Termination Resistor on the 2nd M12 port if
(5 per pack) with socket insert 6GT2 891-4FH50 5 meter pre-assembled cable
RF166C is an end node Reader cable R200/ RF300/ RF600 /MV440
or
For loop-through side of the PROFIBUS network. 6GT2 891-4FN10 10 meter pre-assembled cable
PROFIBUS M12 connector plug 6GK1 905-0EA00 Extension cable
Both ports are used. No Termination Resistor
(5 per pack) with pin insert for RF200/ RF300/ RF600/ MV400 /MV500
needed for that RF166C 6GT2 891-4FN20 20 meter pre-assembled cable

Sold by the meter 6GT2 891-4FN50 50 meter pre-assembled cable


POFIBUS standard non-assembled cable 6XV1 830-0EH10 Minimum length 20 m
Maximum length 10000 m
Reader cable to RF1000 6GT2891-4UH20 2 meter pre-assembled cable

M12 Termination Resistor for PROFIBUS


6GK1 905-0EC00 Required if RF166C is an end-node 5 meter pre-assembled coiled cable with a
(5 per pack) Reader cable to MV320 6GT2191-0BH50
usable length between 1.6 and 4 meter

Use pre-made M12 PROFIBUS connection cables Reader cable MV420 6GF3420-0AC00-2CB0 2 meter pre-assembled cable

See Online Mall 6GF3500-8BA11 0.5 meter pre-assembled cable


PROFIBUS cable with (http://mall.automation.siemens.com)
6XV1 830-3Dxxx* Reader cable MV500
pre-assembled M12 connectors
Lengths available from 0.5 m up to 15 m 6GF3500-8BA12 5 meter pre-assembled cable

M12 Termination Resistor for Additional components


6GK1 905-0EC00 Required if RF166C is an end-node
PROFIBUS (5 per pack)
Covering caps for unused M12 (reader and
3RX9 802-0AA00 1 pack = 10 items
Make your own M12 L-coded power supply connection cables network) ports

Power cable For the supply side of the 24 VDC power, Make your own M12 Ethernet connection cables (needed for web-based management)
6XV1801-2B
(4 wire x 1.5 mm2, trailing type) from 20m up to 1000m
Ethernet to RF166C. 2 x M12
For the supply side of the 24 VDC power, SIMATIC NET Ethernet M12 4-pin connector 6GK1 901-0DB10-6AA0
M12 L-coded – male connector 6GK1906-0EA00 4-pin connectors needed if loop-through
screw joint for wires up to 1.5 mm2
RJ45 connector with metal casing and FC For connection into standard RJ45-type
For the loop-through of 24 VDC power, 6GK1 901-1BB10-2AA0
M12 L-coded – female connector 6GK1906-0EB00 connection system, 180° cable outlet Ethernet switch
screw joint for wires up to 1.5 mm2
Sold by the meter
ETHERNET industrial cable 2x2, Type A,
Use pre-made M12 L-coded power supply connection cables unassembled
6XV1 840-2AH10 Minimum length 20 m; Maximum length
1000 m
Cable for supply voltage with pre-
6XV1801-6Dxxx* Lengths available from 0.5 m up to 15 m Use pre-made M12 Ethernet connection cables (needed for web-based management)
Assembled M12 L-coded connectors 180°

Cable for supply voltage with pre- 2 m– 15 m pre-assembled cable


6XV1801-6Gxxx* Lengths available from 0.5 m up to 15 m Pre-assembled Ethernet cable with 4-pin M12
Assembled M12 L-coded connectors 90° 6XV1871-5Txxx* Use this cable type if the wbm of the RF166C
at RF166C and RJ45 at computer
is directly connected to a PC
Cable for supply voltage assembled with Length 5 m
M12 A-coded 4pin male connector and 6GT2091-0PH50 Useful to connect the CM directly to a power 0.3 m– 15 m pre-assembled cable
Pre-assembled PROFINET cable with 4-pin
M12 L-coded connector female at CM side supply of type 6GT2898-0ACx0 6XV1 870-8xxx* Use this cable type if the RF166C is
M12 on both ends
connected to a IP 65 switch
* These cables are available in various lengths (see catalogue or mall)

Edition: August 2020 SIMATIC Ident Configuration Guide 77


Bulk Cable and Connectors
RF185C, RF186C/CI,
RF166C RF120C ASM 475 RS232 to PC Ethernet to PC RF170C
RF188C/CI

RF200
For IP 67 Master with M12:
For IP 20 Master with screws or push in:
RF2x0R 6XV1 801-2C (5 wire sensor cable; minimum order 20 m)
6XV1 801-2C (5 wire sensor cable; minimum order 20 m)
(IO-Link) 6GK1 909-0DC10-6AA3 (reader connector; never assemble pin 2)
6GK1 909-0DC10-6AA3 (reader connector; never assemble pin 2)
6GK1 909-0DB10-6AA3 (IO-Link master connector)

6GT2 090-4AN50 (50 m cable)


RF2X0R 6GT2 090-4AN50 (50 m cable) 6GT2 090-4AN50 (50 m cable) 6GT2090-4AN50 (50 m cable) 6GT2 090-4AT12 (120 m cable) 6GT2 090-4AN50 (50 m cable) 6GT2 090-4AN50 (50 m cable)
6GT2 090-4AT12 (120 m cable) 6GT2 090-4AT12 (120 m cable) 6GT2 090-4AT12 (120 m cable) 6GT2 090-4AT12 (120 m cable)
RF210M 6GT2090-4AT12 (120 m cable) 6GT2 090-4AT80 (800 m cable)
Not applicable
6GT2 090-4AT80 (800 m cable) 6GT2 090-4AT80 (800 m cable) 6GT2090-4AT80 (800 m cable) 6GT2090-0BD00 (reader 6GT2 090-4AT80 (800 m cable) 6GT2 090-4AT80 (800 m cable)
(RS422) 6GT2090-0BD00 (reader connector) 6GT2090-0BD00 (reader connector) 6GT2090-0BD00 (reader connector) connector) 6GT2090-0BD00 (reader connector) 6GT2090-0BD00 (reader connector)
6GT2090-0BE00 (CM connector) 20-pin S7-300 (CM connector)
(CM type) 9-pin submin-D/M (CM connector)1 PC side: interface converter 6GT2090-0BE00 (CM connector) 6GT2090-0BE00 (CM connector)
RS422/ RS232

RF240R
6GT2 090-4AN50 (50 m cable)
RF250R 6GT2 090-4AT12 (120 m cable)
RF260R 6GT2 090-4AT80 (800 m cable)
Not applicable Not applicable Not applicable Not applicable Not applicable Not applicable
RF285R 6GT2090-0BD00 (reader
RF290R connector)
6GT2 490-1AA00 (PC connector)
(RS232)

RF300
6GT2 090-4AN50 (50 m cable)
6GT2 090-4AN50 (50 m cable) 6GT2 090-4AN50 (50 m cable) 6GT2090-4AN50 (50 m cable) 6GT2 090-4AT12 (120 m cable) 6GT2 090-4AN50 (50 m cable) 6GT2 090-4AN50 (50 m cable)
RF3x0R 6GT2 090-4AT12 (120 m cable) 6GT2 090-4AT12 (120 m cable) 6GT2090-4AT12 (120 m cable) 6GT2 090-4AT80 (800 m cable) 6GT2 090-4AT12 (120 m cable) 6GT2 090-4AT12 (120 m cable)
(RS422) 6GT2 090-4AT80 (800 m cable) 6GT2 090-4AT80 (800 m cable) 6GT2090-4AT80 (800 m cable) Not applicable 6GT2 090-4AT80 (800 m cable) 6GT2 090-4AT80 (800 m cable)
6GT2090-0BD00 (reader
6GT2090-0BD00 (reader connector) 6GT2090-0BD00 (reader connector) 6GT2090-0BD00 (reader connector) connector) 6GT2090-0BD00 (reader connector) 6GT2090-0BD00 (reader connector)
(CM type)
6GT2090-0BE00 (CM connector) 9-pin submin-D/M (CM connector)1 20-pin S7-300 (CM connector) PC side: interface converter 6GT2090-0BE00 (CM connector) 6GT2090-0BE00 (CM connector)
RS422/ RS232

6GT2 090-4AN50 (50 m cable)


6GT2 090-4AT12 (120 m cable)
RF38xR 6GT2 090-4AT80 (800 m cable)
Not applicable Not applicable Not applicable Not applicable Not applicable Not applicable
(RS232) 6GT2090-0BD00 (reader
connector)
6GT2 490-1AA00 (PC connector)

RF600
6XV1 840-2AH10 (>20 m cable)
6GK1901-1BB10-2AA0 (RJ45,
RF650R Not applicable Not applicable Not applicable Not applicable
reader connector + network
Not applicable Not applicable
connector)

RF610R/ 6GT2 090-4AN50 (50 m cable) 6XV1 840-2AH10 (>20 m cable)


6GT2 090-4AT12 (120 m cable) 6GK1901-0DB20-6AA0 (M12 Plug,
RF615R/
6GT2 090-4AT80 (800 m cable) Not applicable Not applicable Not applicable reader connector) Not applicable Not applicable
RF680R/ 6GT2090-0BD00 (reader connector) 6GK1901-1BB10-2AA0 (RJ45,
RF685R 6GT2090-0BE00 (CM connector) network connector)

RF1000
RF1040R/ Always use assembled cables: Always use assembled cables Always use assembled cables:
Not applicable Not applicable Not applicable Not applicable
RF1070R 6GT2891-4UH20 (2m) 6GT2891-4UH20 (2m) 6GT2891-4UH20 (2m)

Edition: August 2020 SIMATIC Ident Configuration Guide 78


Bulk Cable and Connectors

RF185C, RF186C/CI,
RF166C RF120C ASM 475 RS232 to PC Ethernet to PC RF170C
RF188C/CI

MV400 / MV500
6GT2 090-4AN50 (50 m cable) 6GT2 090-4AN50 (50 m cable) 6GT2 090-4AN50 (50 m cable) 6GT2 090-4AN50 (50 m cable) 6XV1 840-2AH10 (>20 m) 6GT2 090-4AN50 (50 m cable) 6GT2 090-4AN50 (50 m cable)
6GT2 090-4AT12 (120 m cable) 6GT2 090-4AT12 (120 m cable) 6GT20 90-4AT12 (120 m cable) 6GT2 090-4AT12 (120 m cable) 6GK1 901-0DB20-6AA0 (4-pin M12 d 6GT2 090-4AT12 (120 m cable) 6GT2 090-4AT12 (120 m cable)
MV420 6GT2 090-4AT80 (800 m cable) 6GT2 090-4AT80 (800 m cable) 6GT2 090-4AT80 (800 m cable) 6GT2 090-4AT80 (800 m cable) coded, reader connector) 6GT2 090-4AT80 (800 m cable) 6GT2 090-4AT80 (800 m cable)
12-pin M16/F (reader connector)2 12-pin M16/F (reader connector)2 12-pin M16/F (reader connector)2 12-pin M16/F (reader connector)2 6GK1901-1BB10-2AA0 (RJ45, 12-pin M16/F (reader connector)2 12-pin M16/F (reader connector)2
6GT2090-0BE00 (CM connector) 9-pin submin-D/M (CM connector)1 20-pin S7-300 (CM connector) 6GT2 490-1AA00 (PC connector) network connector) 6GT2090-0BE00 (CM connector) 6GT2090-0BE00 (CM connector)

6GT2 090-4AN50 (50 m cable) 6GT2 090-4AN50 (50 m cable) 6GT2 090-4AN50 (50 m cable) 6GT2 090-4AN50 (50 m cable) 6XV1 840-2AH10 (>20 m) 6GT2 090-4AN50 (50 m cable) 6GT2 090-4AN50 (50 m cable)
6GT2 090-4AT12 (120 m cable) 6GT2 090-4AT12 (120 m cable) 6GT20 90-4AT12 (120 m cable) 6GT2 090-4AT12 (120 m cable) 6GK1 901-0DB20-6AA0 (4-pin M12 d 6GT2 090-4AT12 (120 m cable) 6GT2 090-4AT12 (120 m cable)
coded, reader connector)
MV440 6GT2 090-4AT80 (800 m cable) 6GT2 090-4AT80 (800 m cable) 6GT2 090-4AT80 (800 m cable) 6GT2 090-4AT80 (800 m cable)
6GK1901-1BB10-2AA0 (RJ45,
6GT2 090-4AT80 (800 m cable) 6GT2 090-4AT80 (800 m cable)
6GT2090-0BD00 (reader connector) 6GT2090-0BD00 (reader connector) 6GT2090-0BD00 (reader connector) 12-pin M16/F (reader connector)2 6GT2090-0BD00 (reader connector) 6GT2090-0BD00 (reader connector)
9-pin submin-D/M (CM connector)1 network connector) 6GT2090-0BE00 (CM connector) 6GT2090-0BE00 (CM connector)
6GT2090-0BE00 (CM connector) 20-pin S7-300 (CM connector) 6GT2 490-1AA00 (PC connector)

Always use reader-side assembled Always use reader-side assembled Always use reader-side assembled Always use reader-side assembled Always use reader-side assembled Always use reader-side assembled Always use reader-side assembled
cables: cables: cables: cables: cables with 90° angled connector cables: cables:
10 m = 6GF3 500-8BA21 10 m = 6GF3 500-8BA21 10 m = 6GF3 500-8BA21 10 m = 6GF3 500-8BA21 100 MB: 10 m = 6GF3 500-8BA21 10 m = 6GF3 500-8BA21
30 m = 6GF3 500-8BA41 30 m = 6GF3 500-8BA41 30 m = 6GF3 500-8BA41 30 m = 6GF3 500-8BA41 6XV1 870-8xxx (0.3 to 15 m) 30 m = 6GF3 500-8BA41 30 m = 6GF3 500-8BA41
6GT2090-0BE00 (CM connector) 9-pin submin-D/M (CM connector)1 20-pin S7-300 (CM connector) 6GT2 490-1AA00 (PC connector) 6GK1 901-1BB10-2AA0 (RJ45, 2x2) 6GT2090-0BE00 (CM connector) 6GT2090-0BE00 (CM connector)
6GK1 901-0DB20-6AA0 (M12, 2x2)
MV500 1000 MB:
6XV1 878-5Gxxx (0.3 to 15 m)
6GK1 901-1BB12-2AA0 (RJ45, 4x2)
6GK1 901-0DB30-6AA0 (M12, 4x2)
The connectors (M12, RJ45) can be
assembled after cutting one connector
of an existing cable

Power & Control-side Networking Components


RF185C, RF186C/CI,
RF166C RF120C ASM 475 RS232 to PC RF600 MV420, MV440 MV500
RF188C/CI

6GT2 090-4AN50 (50 m cable) Always use reader-side


6GT2 090-4AN50 (50 m cable)
Cable & See RF166C Direct in S7-300 rack See RF18xC 6GT2 090-4AT12 (120 m cable) assembled cables (M12, 12pin)
Direct with S7-1200 See individual readers 6GT2 090-4AT12 (120 m cable) and power-side open ends:
Connec- Bill of Materials Guide assembly
or in ET 200M rack
above
bill of materials guide 6GT2 090-4AT80 (800 m cable)
6GT2 090-4AT80 (800 m cable) 10 m = 6GF3 500-8BA21
Page 77 using IM153-2 Module page 75 6GT2090-0BD00 (reader connector)
tors 12-pin M16/F (reader connector)2 30 m = 6GF3 500-8BA41
6GK1907-0DB10-6AA3 (power supply)

Notes:

1. Order via distributor for electronic components


2. Binder M16 male & female connectors for making custom interface cables..
They almost have screw terminals inside of them for wire connections, so they're easy to build in the field.
The contact info is:
Binder-USA – LP offices and warehouse Binder Europa Binder Asia Binder Order example for MV420
3903 Calle Tecate, Camarillo, CA93012 Rötelstrasse 27 74172 Neckarsulm 南京江宁开发区诚信大道88号,7号楼 M16 cable connector 12-pin, female wire solder: 99 5630 00 12
PHONE: (805) 437-9925 PHONE: ++49 (0) 71 32 - 325-0 PHONE: 025-83328591
EMAIL: mailto:[email protected] EMAIL: [email protected] EMAIL: mailto:[email protected]
Web site =http://www.binder-usa.com Web site: http://www.binder-connector.de Web site:http://www.binder-connector.cn

Edition: August 2020 SIMATIC Ident Configuration Guide 79