Schneider VFD Altivar Easy 310 Data Trace Automation
Schneider VFD Altivar Easy 310 Data Trace Automation
Schneider VFD Altivar Easy 310 Data Trace Automation
Catalog
September 2017
General contents
1
Presentation Variable speed drives
AltivarTM Easy 310
Presentation
The AltivarTM Easy 310 drive is a frequency inverter for three-phase 380…460 V
asynchronous motors rated from 0.37 kW/0.5 HP to 11 kW/15 HP.
The compact size of this drive, its robust design, its ease of installation, based on the
principle of Plug & Play, its integrated functions and macro configuration make it
particularly suitable for applications involving industrial machines and certain
consumer machines.
By taking account of the constraints governing installation and use at the product
design stage, we have been able to offer a reliable, cost-effective solution to
manufacturers of compact machines (OEMs).
The Altivar Easy 310 has been developed with no compromise on quality : the
components are designed to last 10 years.
Functions
In addition to the functions usually available on this type of drive, the Altivar Easy 310
drive also features the following:
2
Presentation (continued) Variable speed drives
Altivar Easy 310
An optimized offer
Environment
The entire range conforms to international standards IEC/EN 61800-5-1 and
IEC/EN 61800-3 and has been developed to meet the requirements of directives
regarding the protection of the environment (RoHS, WEEE).
Owing to its innovated air flow design and to its thicker coating which avoids
polluting PCB, the range can be used in the harshest environments. It can withstand
a 55 °C/131 °F ambiant air temperature around the device without derating (1).
Its degree of protection is IP 20 (IP 41 on top of the product).
Easy to commission
Human-Machine Interface (integrated keypad)
The 4-digit display 2 can be used to display states and faults, access parameters
and modify them via the navigation button 3.
The RUN and STOP buttons 4 can be made accessible on the front panel by removing
the blanking plate 5 from the door; they must be configured in order to be active.
Remote display terminal
The Altivar Easy 310 drive can be connected to a remote display terminal, available
as an option. This terminal can be mounted on an enclosure door with IP 54 or IP 65
Remote terminal Remote terminal with cover
with cover closed open: RUN, FWD/REV and degree of protection. The maximum operating temperature is 50 °C/122 °F. It
STOP buttons accessible provides access to the same functions as the Human-Machine interface.
Simple Loader and Multi-Loader configuration tools
The Simple Loader tool enables one powered-up drive's configuration to be
duplicated on another powered-up drive. Operation is very simple.
The Multi-Loader tool enables configurations from a PC or drive to be copied and
duplicated on another drive; the drives do not need to be powered up. The
configuration can be loaded onto the drive without taking it out of its packaging.
Easy to maintain
A warning is sent by the drive to the user when it is necessary to clean heat sink or
replace cooling fan. This fan, which is the only wearing part, can be changed without
the need for any tool.
The security of the system is ensured by an access code allowing authorized people
to configure applications and settings in Configuration mode. Simple users are only
allowed to use the Monitoring mode (parameters display).
Multi-Loader
configuration tool (1) Over this temperature, see the derating curves in the User Manual, available on our website.
(2) For more information, please refer to our local website.
3
Presentation (continued) Variable speed drives
Altivar Easy 310
Main characteristics
Analog input AI1
1 software-configurable voltage or current analog input:
bb Voltage analog input: 0...5 V c (internal power supply only) or 0...10 V c ,
impedance 30 kΩ
bb Analog current input: X-Y mA by programming X and Y from 0–20 mA,
Impedance 250 W
Sampling time: < 20 ms
Resolution: 10 bits
Accuracy: ± 1% at 25 °C/77 °F
Linearity: ± 0.3% of the maximum scale value
Factory setting: Input configured as voltage type
4
References Variable speed drives
Altivar Easy 310
Drives
Drives
PF142119
1.760
0.75 1 3.5 3.1 2.5 5 2.3 3.5 28.83 ATV310H075N4E 0.800/
1.760
1.5 2 6.5 5.4 4.3 5 4.1 6.2 51.82 ATV310HU15N4E 1.100/
2.430
2.2 3 8.8 7.2 5.7 5 5.5 8.3 66.32 ATV310HU22N4E 1.100/
2.430
ATV310HU15N4E 3 4 11.1 9.2 7.3 5 7.1 10.7 80.24 ATV310HU30N4E 1.800/
3.970
4 5 13.7 11.4 9.1 5 9.5 14.3 102.72 ATV310HU40N4E 1.800/
3.970
PF142123
5.5 7.5 21.3 14.3 11.4 22 12.6 18.9 141.54 ATV310HU55N4E 1.800/
3.970
7.5 10 26.6 22.4 17.8 22 17 25.5 203.87 ATV310HU75N4E 3.700/
8.160
11 15 36.1 30.4 24.2 22 24 36 294.70 ATV310HD11N4E 3.700/
8.160
ATV310HU30N4E
Dimensions (overall)
Drives with heatsinks WxHxD
PF142126
mm in.
ATV310H037N4E 72 x 143 x 130 2.83 x 5.63 x 5.12
ATV310H075N4E 72 x 143 x 140 2.83 x 5.63 x 5.51
ATV310HU15N4E, HU22N4E 105 x 143 x 151 4.13 x 5.63 x 5.94
ATV310HU30N4E…HU55N4E 140 x 184 x 151 5.51 x 7.24 x 5.94
ATV310HU75N4E, HD11N4E 150 x 232 x 171 5.91 x 9.13 x 6.73
(1) These values are given for a nominal switching frequency of 4 kHz, for use in continuous operation.
If operation above 4 kHz needs to be continuous, the nominal drive current should be derated by 10% for 8 kHz and
20% for 12 kHz.
The switching frequency can be set between 2 and 12 kHz for all ratings.
Above 4 kHz, the drive will reduce the switching frequency automatically in the event of an excessive temperature rise.
See the derating curves in the User Manual, available on our local website.
(2) Typical value for the indicated motor power and for the maximum prospective line Isc.
ATV310HU75N4E
(3) Weight of product without packaging.
5
References (continued) Variable speed drives
Altivar Easy 310
Configuration tools
Configuration tools
Description For drives Reference Weight
kg/
lb
Simple Loader, Multi-Loader configuration tools and associated cable
Simple Loader tool ATV310HpppN4E VW3A8120 –
For duplicating one drive configuration on another drive.
The drives must be powered-up.
The tool is supplied with a cordset equipped with 2 RJ45
connectors.
Dimensions (overall)
Remote display terminal WxHxD
mm in.
VW3A1006 50 x 70 x 22.7 1.97 x 2.76 x 0.89
VW3A1007 66 x 106 x 26.7 2.6 x 4.17 x 1.05
6
References (continued) Variable speed drives
Altivar Easy 310
Options: line chokes, motor chokes and LR filter cells
Presentation
Line chokes
A line choke can be used to provide improved protection against overvoltages on the line supply and to reduce
harmonic distortion of the current produced by the drive. They are recommended for ATV310…N4E drives.
The recommended chokes limit the line current. They have been developed in line with standard EN 50178
(VDE 0160 level 1 high energy overvoltages on the line supply).
The choke values are defined for a voltage drop between phases of between 3% and 5% of the nominal supply
voltage. Values higher than this will cause loss of torque.
These chokes should be installed upstream of the drive.
The use of line chokes is recommended in particular under the following circumstances:
bb Close connection of several drives in parallel
bb Line supply with significant disturbance from other equipment (interference, overvoltages)
bb Line supply with voltage imbalance between phases above 1.8% of the nominal voltage
bb Drive supplied by a line with very low impedance (in the vicinity of a power transformer 10 times more powerful than
the drive rating)
bb Installation of a large number of frequency inverters on the same line
bb Reducing overloads on the cosϕ correction capacitors, if the installation includes a power factor correction unit.
M1
Motor chokes and LR filter cell
3 Motor chokes are required:
bb When connecting more than 2 motors in parallel
M1
3 bb When the motor cable length (L), including tap-offs, is:
vv 25 m/82.2 ft maximum for a shielded motor cable (1),
M1 vv 50 m/164.4 ft maximum for an unshielded motor cable (1).
3
L LR filter cell comprises 3 high-frequency chokes and 3 resistors.
VW3A455p
Motor choke References
Line chokes
For drives Choke
Line current without choke Line current with choke Reference Weight
380 V 460 V 380 V 460 V
A A A A kg/
lb
ATV310H037N4E 2.1 1.8 1.1 1 VW3A4551 1.500/
ATV310H075N4E 3.5 3.1 1.9 1.7 3.310
ATV310HU15N4E 6.5 5.4 3.5 2.9 VW3A4552 3.700/
PF142110
7
References (continued) Variable speed drives
Altivar Easy 310
Options: braking resistors, Modbus serial link
Braking resistors
For drives Minimum Ohmic value at Power available at Reference Weight
Ohmic value 20° C/68 °F 50° C/122 °F (1)
W W kW kg/
lb
Not protected resistor (IP00) (2)
PF151245A
ATV310HU30N4E 36
ATV310HU40N4E 36
ATV310HU55N4E 28 60 0.16 VW3A7731 2.000/
ATV310HU75N4E 28 4.409
8
Combinations for Variable speed drives
customer assembly Altivar Easy 310
Motor starters
Applications
The proposed combinations can:
bb Protect people and equipment (when a short-circuit occurs)
bb Maintain protection upstream of the drive in the event of a short-circuit on the
power stage
Two types of combination are possible:
bb Drive + circuit-breaker: Minimum combination
bb Drive + circuit-breaker + contactor: Minimum combination with contactor when a
control circuit is needed
Motor starters
Standard Variable speed Combination with control circuit
power drive (circuit-breaker + contactor)
ratings of Minimum combination TeSys
three- (circuit-breaker only) contactor
phase (1)
4-pole TeSys motor Operating
50/60 Hz circuit-breaker range or
motors (3) rating
(2)
kW HP A
M1 A1 Q1 KM1
Three-phase supply voltage: 380…460 V 50/60 Hz (4)
5
1
Q1:
GV2pppp 0.37 0.5 ATV310H037N4E GV2P07 2.5 LC1D09
GV2L07 2.5
2
4
GV2L16 14
A1:
4 5.4 ATV310HU40N4E GV2P16 14 LC1D09
R/L1
S/L2
T/L3
ATV310HpppN4E
GV2L16 14
5.5 7.4 ATV310HU55N4E GV2P22 25 LC1D09
W/T3
U/T1
V/T2
GV2L22 25
7.5 10 ATV310HU75N4E GV2P32 32 LC1D18
GV2L32 32
W1
U1
V1
9
Index Product reference index
A
ATV310H037N4E 5
ATV310H075N4E 5
ATV310HD11N4E 5
ATV310HU15N4E 5
ATV310HU22N4E 5
ATV310HU30N4E 5
ATV310HU40N4E 5
ATV310HU55N4E 5
ATV310HU75N4E 5
L
LU9GC3 8
V
VW3A1006 6
VW3A1007 6
VW3A1104R10 6
VW3A1104R30 6
VW3A4551 7
VW3A4552 7
VW3A4553 7
VW3A4554 7
VW3A7723 8
VW3A7725 8
VW3A7730 8
VW3A7731 8
VW3A7732 8
VW3A8120 6
VW3A8121 6
VW3A8126 6
VW3A8306R 8
VW3A8306R03 8
VW3A8306R10 8
VW3A8306R30 8
VW3A8306RC 8
VW3A8306TF03 8
VW3A8306TF10 8
VW3A58451 7
10
Schneider Electric Industries SAS www.schneider-electric.com
Head Office The information provided in this documentation contains general descriptions and/or technical
35, rue Joseph Monier characteristics of the performance of the products contained herein. This documentation is
F-92500 Rueil-Malmaison not intended as a substitute for and is not to be used for determining suitability or reliability of
France these products for specific user applications. It is the duty of any such user or integrator to
perform the appropriate and complete risk analysis, evaluation and testing of the products with
respect to the relevant specific application or use thereof. Neither Schneider Electric nor any
of its affiliates or subsidiaries shall be responsible or liable for misuse of the information
contained herein.