SAFETY DATA SHEET

Regulation 1907/2006/EC
Shell Corena S2 P 150
Version 3.2 Revision Date 15.01.2016 Print Date 16.01.2016

SECTION 1: Identification of the substance/mixture and of the company/undertaking

1.1 Product identifier


Trade name : Shell Corena S2 P 150
Product code : 001D7780

1.2 Relevant identified uses of the substance or mixture and uses advised against
Use of the : Compressor oil.
Substance/Mixture
Uses advised against :
This product must not be used in applications other than those
listed in Section 1 without first seeking the advice of the
supplier.

1.3 Details of the supplier of the safety data sheet


Manufacturer/Supplier : Shell UK Oil Products Limited
Shell Centre
London
SE1 7NA
United Kingdom
Telephone : (+44) 08007318888
Telefax :
Email Contact for Safety Data : If you have any enquiries about the content of this SDS
Sheet please email [email protected]

1.4 Emergency telephone number


: +44-(0) 151-350-4595

SECTION 2: Hazards identification

2.1 Classification of the substance or mixture


Classification (REGULATION (EC) No 1272/2008)

Not a hazardous substance or mixture.


2.2 Label elements

Labelling (REGULATION (EC) No 1272/2008)


Hazard pictograms : No Hazard Symbol required

Signal word : No signal word

Hazard statements : PHYSICAL HAZARDS:


Not classified as a physical hazard

1 / 17 800001005700
GB
SAFETY DATA SHEET
Regulation 1907/2006/EC
Shell Corena S2 P 150
Version 3.2 Revision Date 15.01.2016 Print Date 16.01.2016

according to CLP criteria.


HEALTH HAZARDS:
Not classified as a health hazard under CLP
criteria.
ENVIRONMENTAL HAZARDS:
Not classified as environmental hazard
according to CLP criteria.

Precautionary statements : Prevention:


No precautionary phrases.
Response:
No precautionary phrases.
Storage:
No precautionary phrases.
Disposal:
No precautionary phrases.

2.3 Other hazards


This mixture does not contain any REACH registered substances that are assessed to be a PBT or a
vPvB.
Prolonged or repeated skin contact without proper cleaning can clog the pores of the skin resulting in
disorders such as oil acne/folliculitis.
Used oil may contain harmful impurities.
Not classified as flammable but will burn.

SECTION 3: Composition/information on ingredients


3.2 Mixtures
Chemical nature : Highly refined mineral oils and additives.
The highly refined mineral oil contains <3% (w/w) DMSO-
extract, according to IP346.

SECTION 4: First aid measures

4.1 Description of first aid measures


General advice : Not expected to be a health hazard when used under normal
conditions.

Protection of first-aiders : When administering first aid, ensure that you are wearing the
appropriate personal protective equipment according to the
incident, injury and surroundings.

If inhaled : No treatment necessary under normal conditions of use.


If symptoms persist, obtain medical advice.

2 / 17 800001005700
GB
SAFETY DATA SHEET
Regulation 1907/2006/EC
Shell Corena S2 P 150
Version 3.2 Revision Date 15.01.2016 Print Date 16.01.2016

In case of skin contact : Remove contaminated clothing. Flush exposed area with
water and follow by washing with soap if available.
If persistent irritation occurs, obtain medical attention.

In case of eye contact : Flush eye with copious quantities of water.


If persistent irritation occurs, obtain medical attention.

If swallowed : In general no treatment is necessary unless large quantities


are swallowed, however, get medical advice.

4.2 Most important symptoms and effects, both acute and delayed
Symptoms : Oil acne/folliculitis signs and symptoms may include formation
of black pustules and spots on the skin of exposed areas.
Ingestion may result in nausea, vomiting and/or diarrhoea.

4.3 Indication of any immediate medical attention and special treatment needed
Treatment : Notes to doctor/physician:
Treat symptomatically.

SECTION 5: Firefighting measures

5.1 Extinguishing media


Suitable extinguishing media : Foam, water spray or fog. Dry chemical powder, carbon
dioxide, sand or earth may be used for small fires only.
Unsuitable extinguishing : Do not use water in a jet.
media
5.2 Special hazards arising from the substance or mixture
Specific hazards during : Hazardous combustion products may include: A complex
firefighting mixture of airborne solid and liquid particulates and gases
(smoke). Carbon monoxide may be evolved if incomplete
combustion occurs. Unidentified organic and inorganic
compounds.
5.3 Advice for firefighters
Special protective equipment : Proper protective equipment including chemical resistant
for firefighters gloves are to be worn; chemical resistant suit is indicated if
large contact with spilled product is expected. Self-Contained
Breathing Apparatus must be worn when approaching a fire in
a confined space. Select fire fighter's clothing approved to
relevant Standards (e.g. Europe: EN469).
Specific extinguishing : Use extinguishing measures that are appropriate to local
methods circumstances and the surrounding environment.

SECTION 6: Accidental release measures

6.1 Personal precautions, protective equipment and emergency procedures

3 / 17 800001005700
GB
SAFETY DATA SHEET
Regulation 1907/2006/EC
Shell Corena S2 P 150
Version 3.2 Revision Date 15.01.2016 Print Date 16.01.2016

Personal precautions : 6.1.1 For non emergency personnel:


Avoid contact with skin and eyes.
6.1.2 For emergency responders:
Avoid contact with skin and eyes.

6.2 Environmental precautions


Environmental precautions : Use appropriate containment to avoid environmental
contamination. Prevent from spreading or entering drains,
ditches or rivers by using sand, earth, or other appropriate
barriers.

Local authorities should be advised if significant spillages


cannot be contained.

6.3 Methods and materials for containment and cleaning up


Methods for cleaning up : Slippery when spilt. Avoid accidents, clean up immediately.
Prevent from spreading by making a barrier with sand, earth
or other containment material.
Reclaim liquid directly or in an absorbent.
Soak up residue with an absorbent such as clay, sand or other
suitable material and dispose of properly.

6.4 Reference to other sections


For guidance on selection of personal protective equipment see Chapter 8 of this Safety Data Sheet.,
For guidance on disposal of spilled material see Chapter 13 of this Safety Data Sheet.

SECTION 7: Handling and storage

General Precautions : Use local exhaust ventilation if there is risk of inhalation of


vapours, mists or aerosols.
Use the information in this data sheet as input to a risk
assessment of local circumstances to help determine
appropriate controls for safe handling, storage and disposal of
this material.

7.1 Precautions for safe handling


Advice on safe handling : Avoid prolonged or repeated contact with skin.
Avoid inhaling vapour and/or mists.
When handling product in drums, safety footwear should be
worn and proper handling equipment should be used.
Properly dispose of any contaminated rags or cleaning
materials in order to prevent fires.

Product Transfer : This material has the potential to be a static accumulator.


Proper grounding and bonding procedures should be used
during all bulk transfer operations.

4 / 17 800001005700
GB
SAFETY DATA SHEET
Regulation 1907/2006/EC
Shell Corena S2 P 150
Version 3.2 Revision Date 15.01.2016 Print Date 16.01.2016

7.2 Conditions for safe storage, including any incompatibilities


Other data : Keep container tightly closed and in a cool, well-ventilated
place. Use properly labeled and closable containers.

Store at ambient temperature.

Refer to section 15 for any additional specific legislation


covering the packaging and storage of this product.

The storage of this product may be subject to the Control of


Pollution (Oil Storage) (England) Regulations. Further
guidance may be obtained from the local environmental
agency office.

Packaging material : Suitable material: For containers or container linings, use mild
steel or high density polyethylene.
Unsuitable material: PVC.

Container Advice : Polyethylene containers should not be exposed to high


temperatures because of possible risk of distortion.

7.3 Specific end use(s)


Specific use(s) : Not applicable

SECTION 8: Exposure controls/personal protection

8.1 Control parameters

Occupational Exposure Limits

Value type (Form


Components CAS-No. Control parameters Basis
of exposure)
Oil mist, mineral TWA 5 mg/m3 US. ACGIH
Threshold
Limit Values

Biological occupational exposure limits


No biological limit allocated.

Monitoring Methods
Monitoring of the concentration of substances in the breathing zone of workers or in the general
workplace may be required to confirm compliance with an OEL and adequacy of exposure controls.
For some substances biological monitoring may also be appropriate.
Validated exposure measurement methods should be applied by a competent person and samples
analysed by an accredited laboratory.
Examples of sources of recommended exposure measurement methods are given below or contact

5 / 17 800001005700
GB
SAFETY DATA SHEET
Regulation 1907/2006/EC
Shell Corena S2 P 150
Version 3.2 Revision Date 15.01.2016 Print Date 16.01.2016

the supplier. Further national methods may be available.


National Institute of Occupational Safety and Health (NIOSH), USA: Manual of Analytical Methods
http://www.cdc.gov/niosh/
Occupational Safety and Health Administration (OSHA), USA: Sampling and Analytical Methods
http://www.osha.gov/
Health and Safety Executive (HSE), UK: Methods for the Determination of Hazardous Substances
http://www.hse.gov.uk/
Institut für Arbeitsschutz Deutschen Gesetzlichen Unfallversicherung (IFA) , Germany
http://www.dguv.de/inhalt/index.jsp
L'Institut National de Recherche et de Securité, (INRS), France http://www.inrs.fr/accueil

8.2 Exposure controls


Engineering measuresThe level of protection and types of controls necessary will vary depending
upon potential exposure conditions. Select controls based on a risk assessment of local
circumstances. Appropriate measures include:
Adequate ventilation to control airborne concentrations.

Where material is heated, sprayed or mist formed, there is greater potential for airborne
concentrations to be generated.

General Information:
Define procedures for safe handling and maintenance of controls.
Educate and train workers in the hazards and control measures relevant to normal activities
associated with this product.
Ensure appropriate selection, testing and maintenance of equipment used to control exposure, e.g.
personal protective equipment, local exhaust ventilation.
Drain down system prior to equipment break-in or maintenance.
Retain drain downs in sealed storage pending disposal or subsequent recycle.
Always observe good personal hygiene measures, such as washing hands after handling the material
and before eating, drinking, and/or smoking. Routinely wash work clothing and protective equipment
to remove contaminants. Discard contaminated clothing and footwear that cannot be cleaned.
Practice good housekeeping.
Personal protective equipment
The provided information is made in consideration of the PPE directive (Council Directive
89/686/EEC) and the CEN European Committee for Standardisation (CEN) standards.

Personal protective equipment (PPE) should meet recommended national standards. Check with
PPE suppliers.

Eye protection : If material is handled such that it could be splashed into eyes,
protective eyewear is recommended.
Approved to EU Standard EN166.

Hand protection

Remarks : Where hand contact with the product may occur the use of
gloves approved to relevant standards (e.g. Europe: EN374,
US: F739) made from the following materials may provide
suitable chemical protection. PVC, neoprene or nitrile rubber

6 / 17 800001005700
GB
SAFETY DATA SHEET
Regulation 1907/2006/EC
Shell Corena S2 P 150
Version 3.2 Revision Date 15.01.2016 Print Date 16.01.2016

gloves Suitability and durability of a glove is dependent on


usage, e.g. frequency and duration of contact, chemical
resistance of glove material, dexterity. Always seek advice
from glove suppliers. Contaminated gloves should be
replaced. Personal hygiene is a key element of effective hand
care. Gloves must only be worn on clean hands. After using
gloves, hands should be washed and dried thoroughly.
Application of a non-perfumed moisturizer is recommended.

For continuous contact we recommend gloves with


breakthrough time of more than 240 minutes with preference
for > 480 minutes where suitable gloves can be identified. For
short-term/splash protection we recommend the same, but
recognize that suitable gloves offering this level of protection
may not be available and in this case a lower breakthrough
time maybe acceptable so long as appropriate maintenance
and replacement regimes are followed. Glove thickness is not
a good predictor of glove resistance to a chemical as it is
dependent on the exact composition of the glove material.
Glove thickness should be typically greater than 0.35 mm
depending on the glove make and model.

Skin and body protection : Skin protection is not ordinarily required beyond standard
work clothes.
It is good practice to wear chemical resistant gloves.

Respiratory protection : No respiratory protection is ordinarily required under normal


conditions of use.
In accordance with good industrial hygiene practices,
precautions should be taken to avoid breathing of material.
If engineering controls do not maintain airborne
concentrations to a level which is adequate to protect worker
health, select respiratory protection equipment suitable for the
specific conditions of use and meeting relevant legislation.
Check with respiratory protective equipment suppliers.
Where air-filtering respirators are suitable, select an
appropriate combination of mask and filter.
Select a filter suitable for combined particulate/organic gases
and vapours [Type A/Type P boiling point > 65°C (149°F)]
meeting EN14387 and EN143.

Thermal hazards : Not applicable

Hygiene measures : Exposure to this product should be reduced as low as


reasonably practicable. Reference should be made to the
Health and Safety Executive's publication "COSHH
Essentials".

7 / 17 800001005700
GB
SAFETY DATA SHEET
Regulation 1907/2006/EC
Shell Corena S2 P 150
Version 3.2 Revision Date 15.01.2016 Print Date 16.01.2016

Environmental exposure controls


General advice : Take appropriate measures to fulfill the requirements of
relevant environmental protection legislation. Avoid
contamination of the environment by following advice given in
Chapter 6. If necessary, prevent undissolved material from
being discharged to waste water. Waste water should be
treated in a municipal or industrial waste water treatment plant
before discharge to surface water.
Local guidelines on emission limits for volatile substances
must be observed for the discharge of exhaust air containing
vapour.

SECTION 9: Physical and chemical properties

9.1 Information on basic physical and chemical properties


Appearance : Liquid at room temperature.

Colour : light brown


Odour : Slight hydrocarbon
Odour Threshold : Data not available
pH : Not applicable
pour point : -30 °CMethod: ASTM D97

Initial boiling point and boiling : > 280 °Cestimated value(s)


range
Flash point : 240 °C
Method: ASTM D92

Evaporation rate : Data not available


Flammability (solid, gas) : Data not available

Upper explosion limit : Typical 10 %(V)

Lower explosion limit : Typical 1 %(V)

Vapour pressure : < 0.5 Pa (20 °C)


estimated value(s)
Relative vapour density : > 1estimated value(s)
Relative density : 0.902 (15 °C)

Density : 902 kg/m3 (15.0 °C)


Method: ASTM D1298

Solubility(ies)

8 / 17 800001005700
GB
SAFETY DATA SHEET
Regulation 1907/2006/EC
Shell Corena S2 P 150
Version 3.2 Revision Date 15.01.2016 Print Date 16.01.2016

Water solubility : negligible


Solubility in other solvents : Data not available

Partition coefficient: n- : Pow: > 6(based on information on similar products)


octanol/water
Auto-ignition temperature : >
320 °C

Viscosity
Viscosity, dynamic : Data not available
Viscosity, kinematic : 155 mm2/s (40.0 °C)
Method: ASTM D445

12.1 mm2/s (100 °C)


Method: ASTM D445

Explosive properties : Not classified

Oxidizing properties : Data not available

9.2 Other information

Conductivity : This material is not expected to be a static accumulator.


Decomposition temperature : Data not available

SECTION 10: Stability and reactivity

10.1 Reactivity
The product does not pose any further reactivity hazards in addition to those listed in the following
sub-paragraph.
10.2 Chemical stability
Stable.
No hazardous reaction is expected when handled and stored according to provisions
10.3 Possibility of hazardous reactions
Hazardous reactions : Reacts with strong oxidising agents.

10.4 Conditions to avoid


Conditions to avoid : Extremes of temperature and direct sunlight.

10.5 Incompatible materials


Materials to avoid : Strong oxidising agents.

9 / 17 800001005700
GB
SAFETY DATA SHEET
Regulation 1907/2006/EC
Shell Corena S2 P 150
Version 3.2 Revision Date 15.01.2016 Print Date 16.01.2016

10.6 Hazardous decomposition products


Hazardous decomposition : Hazardous decomposition products are not expected to form
products during normal storage.

SECTION 11: Toxicological information


11.1 Information on toxicological effects

Basis for assessment : Information given is based on data on the components and
the toxicology of similar products.Unless indicated otherwise,
the data presented is representative of the product as a
whole, rather than for individual component(s).
Information on likely routes of : Skin and eye contact are the primary routes of exposure
exposure although exposure may occur following accidental ingestion.

Acute toxicity
Product:
Acute oral toxicity : LD50 rat: > 5,000 mg/kg
Remarks: Expected to be of low toxicity:

Acute inhalation toxicity : Remarks: Not considered to be an inhalation hazard under


normal conditions of use.

Acute dermal toxicity : LD50 Rabbit: > 5,000 mg/kg


Remarks: Expected to be of low toxicity:

Skin corrosion/irritation
Product:
Remarks: Expected to be slightly irritating., Prolonged or repeated skin contact without proper
cleaning can clog the pores of the skin resulting in disorders such as oil acne/folliculitis.

Serious eye damage/eye irritation


Product:
Remarks: Expected to be slightly irritating.

Respiratory or skin sensitisation


Product:
Remarks: For respiratory and skin sensitisation:, Not expected to be a sensitiser.

Germ cell mutagenicity

10 / 17 800001005700
GB
SAFETY DATA SHEET
Regulation 1907/2006/EC
Shell Corena S2 P 150
Version 3.2 Revision Date 15.01.2016 Print Date 16.01.2016

Product:
: Remarks: Not considered a mutagenic hazard.
Carcinogenicity
Product:

Remarks: Not expected to be carcinogenic.

Remarks: Product contains mineral oils of types shown to be non-carcinogenic in animal skin-
painting studies., Highly refined mineral oils are not classified as carcinogenic by the
International Agency for Research on Cancer (IARC).

Material GHS/CLP Carcinogenicity Classification


Highly refined mineral oil No carcinogenicity classification.

Reproductive toxicity

Product:
:
Remarks: Not expected to impair fertility., Not expected to be
a developmental toxicant.

STOT - single exposure


Product:
Remarks: Not expected to be a hazard.

STOT - repeated exposure


Product:
Remarks: Not expected to be a hazard.

Aspiration toxicity
Product:
Not considered an aspiration hazard.

Further information
Product:
Remarks: Used oils may contain harmful impurities that have accumulated during use. The
concentration of such impurities will depend on use and they may present risks to health and the

11 / 17 800001005700
GB
SAFETY DATA SHEET
Regulation 1907/2006/EC
Shell Corena S2 P 150
Version 3.2 Revision Date 15.01.2016 Print Date 16.01.2016

environment on disposal., ALL used oil should be handled with caution and skin contact avoided
as far as possible.

Remarks: Slightly irritating to respiratory system.

Remarks: Classifications by other authorities under varying regulatory frameworks may exist.

Summary on evaluation of the CMR properties


Germ cell mutagenicity- : This product does not meet the criteria for classification in
Assessment categories 1A/1B.

Carcinogenicity - : This product does not meet the criteria for classification in
Assessment categories 1A/1B.

Reproductive toxicity - : This product does not meet the criteria for classification in
Assessment categories 1A/1B.

SECTION 12: Ecological information

12.1 Toxicity

Basis for assessment : Ecotoxicological data have not been determined specifically
for this product.
Information given is based on a knowledge of the components
and the ecotoxicology of similar products.
Unless indicated otherwise, the data presented is
representative of the product as a whole, rather than for
individual component(s).(LL/EL/IL50 expressed as the
nominal amount of product required to prepare aqueous test
extract).
Product:
Toxicity to fish (Acute : Remarks: Expected to be practically non toxic:
toxicity) LL/EL/IL50 > 100 mg/l

Toxicity to crustacean (Acute : Remarks: Expected to be practically non toxic:


toxicity) LL/EL/IL50 > 100 mg/l

Toxicity to algae/aquatic : Remarks: Expected to be practically non toxic:


plants (Acute toxicity) LL/EL/IL50 > 100 mg/l

Toxicity to fish (Chronic : Remarks: Data not available


toxicity)
Toxicity to crustacean : Remarks: Data not available
(Chronic toxicity)
Toxicity to microorganisms :
(Acute toxicity) Remarks: Data not available

12 / 17 800001005700
GB
SAFETY DATA SHEET
Regulation 1907/2006/EC
Shell Corena S2 P 150
Version 3.2 Revision Date 15.01.2016 Print Date 16.01.2016

12.2 Persistence and degradability


Product:
Biodegradability : Remarks: Expected to be not readily biodegradable., Major
constituents are expected to be inherently biodegradable, but
contains components that may persist in the environment.

12.3 Bioaccumulative potential


Product:
Bioaccumulation : Remarks: Contains components with the potential to
bioaccumulate.

Partition coefficient: n- : Pow: > 6Remarks: (based on information on similar products)


octanol/water
12.4 Mobility in soil
Product:
Mobility : Remarks: Liquid under most environmental conditions., If it
enters soil, it will adsorb to soil particles and will not be
mobile.
Remarks: Floats on water.
12.5 Results of PBT and vPvB assessment
Product:
Assessment : This mixture does not contain any REACH registered
substances that are assessed to be a PBT or a vPvB.
12.6 Other adverse effects
Product:
Additional ecological : Product is a mixture of non-volatile components, which are not
information expected to be released to air in any significant quantities.,
Not expected to have ozone depletion potential,
photochemical ozone creation potential or global warming
potential.
Poorly soluble mixture., May cause physical fouling of aquatic
organisms.
Mineral oil is not expected to cause any chronic effects to
aquatic organisms at concentrations less than 1 mg/l.

SECTION 13: Disposal considerations

13.1 Waste treatment methods


Product : Waste product should not be allowed to contaminate soil or

13 / 17 800001005700
GB
SAFETY DATA SHEET
Regulation 1907/2006/EC
Shell Corena S2 P 150
Version 3.2 Revision Date 15.01.2016 Print Date 16.01.2016

ground water, or be disposed of into the environment.


Waste, spills or used product is dangerous waste.

Disposal should be in accordance with applicable regional,


national, and local laws and regulations.
Local regulations may be more stringent than regional or
national requirements and must be complied with.

Contaminated packaging : Dispose in accordance with prevailing regulations, preferably


to a recognized collector or contractor. The competence of
the collector or contractor should be established beforehand.
Disposal should be in accordance with applicable regional,
national, and local laws and regulations.

Local legislation
Waste catalogue : EU Waste Disposal Code (EWC):

Waste Code : 13 02 05*

Remarks : Classification of waste is always the responsibility of the end


user.

SECTION 14: Transport information

14.1 UN number
ADR : Not regulated as a dangerous good
RID : Not regulated as a dangerous good
IMDG : Not regulated as a dangerous good
IATA : Not regulated as a dangerous good
14.2 Proper shipping name
ADR : Not regulated as a dangerous good
RID : Not regulated as a dangerous good
IMDG : Not regulated as a dangerous good
IATA : Not regulated as a dangerous good
14.3 Transport hazard class
ADR : Not regulated as a dangerous good
RID : Not regulated as a dangerous good
IMDG : Not regulated as a dangerous good
IATA : Not regulated as a dangerous good
14.4 Packing group
ADR : Not regulated as a dangerous good
RID : Not regulated as a dangerous good
IMDG : Not regulated as a dangerous good
IATA : Not regulated as a dangerous good
14.5 Environmental hazards
ADR : Not regulated as a dangerous good
RID : Not regulated as a dangerous good
IMDG : Not regulated as a dangerous good

14 / 17 800001005700
GB
SAFETY DATA SHEET
Regulation 1907/2006/EC
Shell Corena S2 P 150
Version 3.2 Revision Date 15.01.2016 Print Date 16.01.2016

14.6 Special precautions for user


Remarks : Special Precautions: Refer to Chapter 7, Handling & Storage,
for special precautions which a user needs to be aware of or
needs to comply with in connection with transport.

14.7 Transport in bulk according to Annex II of MARPOL 73/78 and the IBC Code
Pollution category : Not applicable
Ship type : Not applicable
Product name : Not applicable
Special precautions : Not applicable

Additional Information : MARPOL Annex 1 rules apply for bulk shipments by sea.

SECTION 15: Regulatory information

15.1 Safety, health and environmental regulations/legislation specific for the substance or mixture
REACH - List of substances subject to authorisation : Product is not subject to
(Annex XIV) Authorisation under REACH.

Volatile organic compounds : 0%

Other regulations : Environmental Protection Act 1990 (as amended). Health and
Safety at Work etc. Act 1974. Consumers Protection Act 1987.
Pollution Prevention and Control Act 1999. Environment Act
1995. Factories Act 1961. The Carriage of Dangerous Goods
and Use of Transportable Pressure Equipment (Amendment)
Regulations 2011. Chemicals (Hazard Information and
Packaging for Supply) Regulations 2009. Control of
Substances Hazardous to Health Regulations 2002 (as
amended). Merchant Shipping (Dangerous Goods and Marine
Pollutants) Regulations 1997. Reporting of Injuries, Diseases
and Dangerous Occurrences Regulations 1995 (as amended).
Personal Protective Equipment Regulations 2002. Personal
Protective Equipment at Work Regulations 1992. Hazardous
Waste (England and Wales) Regulations 2005(as amended).
Control of Major Accident Hazards Regulations 1999 (as
amended). Renewable Transport Fuel Obligations Order 2007
(as amended). Energy Act 2011. Environmental Permitting
(England and Wales) Regulations 2010 (as amended). Waste
(England and Wales) Regulations 2011 (as amended).
Planning (Hazardous Substances) Act 1990 and associated
regulations. The Environmental Protection (Controls on
Ozone-Depleting Substances) Regulations 2011.

The components of this product are reported in the following inventories:

15 / 17 800001005700
GB
SAFETY DATA SHEET
Regulation 1907/2006/EC
Shell Corena S2 P 150
Version 3.2 Revision Date 15.01.2016 Print Date 16.01.2016

EINECS : All components listed or polymer exempt.


TSCA : All components listed.

15.2 Chemical safety assessment


No Chemical Safety Assessment has been carried out for this substance/mixture by the supplier.

SECTION 16: Other information


,

Abbreviations and Acronyms : The standard abbreviations and acronyms used in this
document can be looked up in reference literature (e.g.
scientific dictionaries) and/or websites.

ACGIH = American Conference of Governmental Industrial


Hygienists
ADR = European Agreement concerning the International
Carriage of Dangerous Goods by Road
AICS = Australian Inventory of Chemical Substances
ASTM = American Society for Testing and Materials
BEL = Biological exposure limits
BTEX = Benzene, Toluene, Ethylbenzene, Xylenes
CAS = Chemical Abstracts Service
CEFIC = European Chemical Industry Council
CLP = Classification Packaging and Labelling
COC = Cleveland Open-Cup
DIN = Deutsches Institut fur Normung
DMEL = Derived Minimal Effect Level
DNEL = Derived No Effect Level
DSL = Canada Domestic Substance List
EC = European Commission
EC50 = Effective Concentration fifty
ECETOC = European Center on Ecotoxicology and
Toxicology Of Chemicals
ECHA = European Chemicals Agency
EINECS = The European Inventory of Existing Commercial
Chemical Substances
EL50 = Effective Loading fifty
ENCS = Japanese Existing and New Chemical Substances
Inventory
EWC = European Waste Code
GHS = Globally Harmonised System of Classification and
Labelling of Chemicals
IARC = International Agency for Research on Cancer
IATA = International Air Transport Association
IC50 = Inhibitory Concentration fifty
IL50 = Inhibitory Level fifty
IMDG = International Maritime Dangerous Goods
INV = Chinese Chemicals Inventory
IP346 = Institute of Petroleum test method N° 346 for the

16 / 17 800001005700
GB
SAFETY DATA SHEET
Regulation 1907/2006/EC
Shell Corena S2 P 150
Version 3.2 Revision Date 15.01.2016 Print Date 16.01.2016

determination of polycyclic aromatics DMSO-extractables


KECI = Korea Existing Chemicals Inventory
LC50 = Lethal Concentration fifty
LD50 = Lethal Dose fifty per cent.
LL/EL/IL = Lethal Loading/Effective Loading/Inhibitory loading
LL50 = Lethal Loading fifty
MARPOL = International Convention for the Prevention of
Pollution From Ships
NOEC/NOEL = No Observed Effect Concentration / No
Observed Effect Level
OE_HPV = Occupational Exposure - High Production Volume
PBT = Persistent, Bioaccumulative and Toxic
PICCS = Philippine Inventory of Chemicals and Chemical
Substances
PNEC = Predicted No Effect Concentration
REACH = Registration Evaluation And Authorisation Of
Chemicals
RID = Regulations Relating to International Carriage of
Dangerous Goods by Rail
SKIN_DES = Skin Designation
STEL = Short term exposure limit
TRA = Targeted Risk Assessment
TSCA = US Toxic Substances Control Act
TWA = Time-Weighted Average
vPvB = very Persistent and very Bioaccumulative

Further information
Other information : No Exposure Scenario annex is attached to this safety data
sheet as it is a non-classified mixture containing no hazardous
substances.
Under Article 31 of REACH, a SDS is not required for this
product. Therefore, this SDS has been created on a voluntary
basis to pass on potentially relevant information required
under Article 32.

A vertical bar (|) in the left margin indicates an amendment


from the previous version.

This information is based on our current knowledge and is intended to describe the product for the
purposes of health, safety and environmental requirements only. It should not therefore be
construed as guaranteeing any specific property of the product.

17 / 17 800001005700
GB

You might also like