Compression Load Cell Inteco, Converter Connexx, Mounting Kits PR 6001, PR 614x
Compression Load Cell Inteco, Converter Connexx, Mounting Kits PR 6001, PR 614x
Minimum dead load Lowest limit of specified measuring range Emin 0 %Emax
Maximum capacity Highest limit of specified measuring range Emax See Ordering information table kg
Safe load limit Maximum load without irreversible damage Elim For 500 kg … 50 t: 150 %Emax
For 60 t: 125
For 75 t: 100
Destructive load Danger of mechanical destruction Ed For 500 kg … 50 t: >300 %Emax
For 60 t: >250
For 75 t: >200
Minimum LC verification Minimum load cell verification interval See Accuracy classes and minimum
(vmin = Emax/Y) verification interval, vmin table
For Emax = 500 kg Y 2,500 n.a. n.a.
Tolerance on rated output Permissible deviation from rated output dc <0.25 <0.07 <0.07 %Cn
Zero output signal Load cell output signal under unloaded condition Smin 0±1.0 0±1.0 0±1.0 %Cn
Reproducibility Max. change in load cell output for repeated eR 0.01 0.005 0.005 %Cn
loading
Creep Max. change of output signal at Emax for 30 min. dcr <0.03 <0.015 <0.008 %Cn
Non-linearity Max. deviation from best straight line through zero dLin <0.03 <0.01 <0.01 %Cn
Hysteresis Max. difference in LC output between loading and dhy <0.04 <0.015 <0.008 %Cn
unloading
Temperature effect (TK) on Smin Max. change of Smin in BT TKSmin <0.028 <0.010 <0.007 %Cn/10 K
Temperature effect (TK) on Max. change of C in BT TKC <0.03 <0.010 <0.005 %Cn/10 K
parameter
Input impedance Between supply terminals RLC 650 ±6 650 ±6 650 ±6 Ω
Output impedance Between supply terminals RO 610 ±1 610 ±0.5 610 ±0.5 Ω
Max. supply voltage Permissible for continuous operation without Umax 32 (Ex versions: 25) V
damage
Nominal ambient temp. range To hold the specified performance BT -10 … +40 -10 … +40 -10 … +40 °C
Usable temperature range Permissible for continuous operation without BTu -40 … +95 -40 … +95 -40 … +95 °C
damage
Storage temperature range Without electrical and mechanical stress BTi -40 … +95 -40 … +95 -40 … +95 °C
Material (load cell housing) Stainless steel 1.4301 acc. DIN EN 10088-3 (conforms to 304 AISI)
Permissible eccentricity Permissible displacement from nominal load line Sex For 500 kg … 10 t: 10 mm
For 20 t … 75 t: 5
Vibration resistance Resistance against oscillations 20 g, 100 h, 10 … 150 Hz
(IEC 68-2-6 Fc)
Parameter Description Abbr. PR 6203 D1/N PR 6203 C3 PR 6203 C6 Unit
Barometric pressure influence Influence of barometric pressure on output PKSmin 500 kg … 3 t: 200 g/kPa
5 t … 10 t: 330
20 t … 75 t: 420
Nominal deflection Max. elastic deformation under maximum capacity Snom ≤5 t: ≤0.3/≤20 t: ≤0.5/≤50 t: ≤0.8/ mm
60 t … 75 t: ≤1.2
Protection class according to IEC 529
– Inteco: IP68*/IP69
– Connexx®: IP65 / IP 68**
Cable Length: Emax ≤10 t: 5 m, Emax >10 t: 12 m
Diameter: 5 mm
Cross section: 4 × 0.35 mm2
Material cable sheath: TPE
Bending radius ≥25 mm in case of fixed installation
≥75 mm in case of flexible installation
Connexx®
Usable temperature range Permissible for continuous operation without BTu -30 … +60 °C
damage
Storage temperature range Without electrical and mechanical stress BTi -30 … +70 °C
* The load cell can be submerged in water at a depth of 1.5 m for 10,000 hours.
** The module can be submerged in water at a depth of 1.5 m for 100 hours.
Maximum number of verification 1,000 3,000 6,000 1,000 5,000 10,000 2,000 10,000 10,000
intervals, nmax
500 kg 0.2 kg n.a. n.a. 0.2 kg n.a. n.a. n.a. n.a. n.a.
Mounting screws
Max. permissible
Max. permissible
Max. permissible
Max. permissible
Max. permissible
destructive force
horizontal force
ity of load cell
according to
Mounting kit/ Description/
CE approval
eccentricity
Material
Horizontal
force [KN]
accessories comments
delivery)
EN 1090
Inteco®
(mm)
(kN)
[KN]
Steel electrogal-
Mounting disc
vanised, chromated
PR 6001/00N incl. upper load M12-8.8 20 50 Yes
and sealed (RoHS
disc
compliant) /
Mounting kit
Stainless steel
PR 6001/00S incl. upper and M12-A2-70 20 50 /
1.4301 (AISI 304)
lower load disc
Steel electrogal-
vanised, chromated
PR 6001/10N MaxiFLEXLOCK M12-8.8 45 50 Yes
and sealed (RoHS 190.5 20 ± 5 25 t 1.5 t
500 kg – 10 t
compliant) 25
Stainless steel
PR 6001/10S MaxiFLEXLOCK M12-A2-70 39 50 /
1.4301 (AISI 304)
Steel electrogal-
vanised, chromated
PR 6001/20N MaxiFLEXLOCK M16-8.8 100 50 Yes
and sealed (RoHS
compliant) 50
Stainless steel
PR 6001/20S MaxiFLEXLOCK M16-A2-70 100 50 /
1.4301 (AISI 304)
Steel electrogal- High-load
vanised, chromated mounting kit
PR 6001/30N M20-8.8 250.5 200 236 250 180 ± 5 25 t 1.5 t Yes
and sealed (RoHS incl. upper load
compliant) disc
Steel electrogal-
Mounting kit
vanised, chromated
PR 6001/01N including upper M12-8.8 20 50 Yes
and sealed (RoHS
load disc
compliant) /
Mounting kit
Stainless steel
PR 6001/01S incl. upper and M12-A2-70 20 50 /
1.4301 (AISI 304)
lower load disc
Steel electrogal-
vanised, chromated Yes
PR 6001/11N MaxiFLEXLOCK M12-8.8 45 50
and sealed (RoHS 190.5 30 ± 5 25 t /
compliant) 25
Stainless steel
PR 6001/11S MaxiFLEXLOCK M12-A2-70 39 50 /
20 t – 75 t
1.4301 (AISI 304)
Steel electrogal-
vanised, chromated
PR 6001/21N MaxiFLEXLOCK M16-8.8 100 50 Yes
and sealed (RoHS
compliant) 50
Stainless steel
PR 6001/21S MaxiFLEXLOCK M16-A2-70 100 50 /
1.4301 (AISI 304)
Steel electrogal-
vanised, chromated
PR 6001/26N MaxiFLEXLOCK M20-8.8 50 100 250 Yes
and sealed (RoHS
compliant)
250.5 180 ± 5 25 t /
Steel electrogal- High-load
vanised, chromated mounting kit
PR 6001/31N M20-8.8 200 236 250 Yes
and sealed (RoHS incl. upper load
compliant) disc
Mounting kit PR 6143
Installation height
Maximum capac-
Mounting screws
Max. permissible
destructive force
(not included in
horizontal force
according to
Mounting kit/ Description/
CE approval
Material
Horizontal
accessories comments
delivery)
EN 1090
Inteco®
(kN)**
(mm)
(kN)
[KN]
500 kg –
10 t
Steel electrogalvanised,
PR 6143/50N chromated and sealed Upper load disc / / / / / /
(RoHS compliant)
PR 6143/50S Stainless steel 1.4542 Upper load disc / / / / / /
Steel electrogalvanised,
MiniFLEXLOCK
500 kg – 75 t
Mounting screws
Max. permissible
Max. permissible
destructive force
according to
according to
Mounting kit/ Description/
CE approval
Material
Horizontal
force [KN]
accessories comments
delivery)
EN 1090
EN 1090
Inteco®
(mm)
[KN]
PR 6144/54N chromated and sealed incl. load cell M30-8.8 217 370 600 600 400 16 t Yes
(RoHS compliant) dummy
Mounting screws
(not included in
ity of load cell
according to
Material
accessories comments
delivery)
EN 1090
Inteco®
(mm)
Installation height
Maximum capac-
Mounting screws
destructive force
Horizontal
delivery)
Inteco®
(mm)
[KN]
Steel electrogalvanised, chromated and sealed 5t 15
PR 6101/53N M12-8.8 25
(RoHS compliant) 10 t 12
190.5
5t
5t 10
PR 6101/53S Stainless steel 1.4301 (AISI 304) M12-A2-70 16
10 t 8.5
190.5
20 t 30
PR 6101/24S Stainless steel 1.4301 (AISI 304) M12-A2-70 40
40 t 20
190.5
50 t 50
PR 6101/54S Stainless steel 1.4301 (AISI 304) M12-A2-70 150
75 t 20
Converter Connexx®
All dimensions in mm
Technical diagrams
Load cells Inteco®/PR 6203
Converter Connexx®
Converter Connexx®
All dimensions in mm