Compression Load Cell Inteco, Converter Connexx, Mounting Kits PR 6001, PR 614x

The document discusses a load cell and converter solution for weighing silos and vessels. It provides technical specifications for the Inteco load cell and Connexx converter, including accuracy classes, capacity ranges, temperature ranges, material properties, and other parameters. The solution offers fast signaling, transparency, and minimizes the effect of movements on weighing.

Uploaded by

Yuli anto
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
89 views7 pages

Compression Load Cell Inteco, Converter Connexx, Mounting Kits PR 6001, PR 614x

The document discusses a load cell and converter solution for weighing silos and vessels. It provides technical specifications for the Inteco load cell and Connexx converter, including accuracy classes, capacity ranges, temperature ranges, material properties, and other parameters. The solution offers fast signaling, transparency, and minimizes the effect of movements on weighing.

Uploaded by

Yuli anto
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 7

Compression load cell Inteco®, converter

­Connexx®, mounting kits PR 6001, PR 614x


The versatile, innovative weighing solution for silo and vessel weighing

The load cell Inteco®/PR 6203 represents a consistent enhancement to


the well-known PR 6201. With an output signal of 2 mV/V, additional load
levels of up to 75 t, higher accuracy classes (C6) and high-quality
stainless steel, it has a wider range of potential applications. As a digital
weighing solution with the converter Connexx®, the load cell Inteco®
offers fast signalling times and optimal transparency in dosing and
weighing processes. The Minebea Intec mounting kits FLEXLOCK
minimise the effect of movements on the weighing result at the same
time.

The right solution for all of these applications:

Weighing Filling and Fill quantity


dosing control
Technical specifications
Compression load cell Inteco®/PR 6203 (500 kg – 75 t)

Parameter Description Abbr. PR 6203 D1/N PR 6203 C3 PR 6203 C6 Unit

Accuracy class 0.04 0.015 0.008 %Emax

Minimum dead load Lowest limit of specified measuring range Emin 0 %Emax

Maximum capacity Highest limit of specified measuring range Emax See Ordering information table kg

Safe load limit Maximum load without irreversible damage Elim For 500 kg … 50 t: 150 %Emax
For 60 t: 125
For 75 t: 100
Destructive load Danger of mechanical destruction Ed For 500 kg … 50 t: >300 %Emax
For 60 t: >250
For 75 t: >200
Minimum LC verification Minimum load cell verification interval See Accuracy classes and minimum
(vmin = Emax/Y) verification interval, vmin table
For Emax = 500 kg Y 2,500 n.a. n.a.

For Emax = 1 t Y 5,000 n.a. n.a.

For Emax = 2 t Y 5,000 10,000 n.a.

For Emax = 3 t … 75 t Y 5,000 14,000 3 t – 10 t:


14,000
>20 t:
20,000
Deadload output return Factor for deadload output return after load Z 1,000 3,000 6,000
(DR=1/2*Emax/Z)
Rated output Relative output at maximum capacity Cn 2 2 2 mV/V

Tolerance on rated output Permissible deviation from rated output dc <0.25 <0.07 <0.07 %Cn

Zero output signal Load cell output signal under unloaded condition Smin 0±1.0 0±1.0 0±1.0 %Cn

Reproducibility Max. change in load cell output for repeated eR 0.01 0.005 0.005 %Cn
loading
Creep Max. change of output signal at Emax for 30 min. dcr <0.03 <0.015 <0.008 %Cn

Non-linearity Max. deviation from best straight line through zero dLin <0.03 <0.01 <0.01 %Cn

Hysteresis Max. difference in LC output between loading and dhy <0.04 <0.015 <0.008 %Cn
unloading
Temperature effect (TK) on Smin Max. change of Smin in BT TKSmin <0.028 <0.010 <0.007 %Cn/10 K

Temperature effect (TK) on Max. change of C in BT TKC <0.03 <0.010 <0.005 %Cn/10 K
parameter
Input impedance Between supply terminals RLC 650 ±6 650 ±6 650 ±6 Ω

Output impedance Between supply terminals RO 610 ±1 610 ±0.5 610 ±0.5 Ω

For Emax = 60 t RO 510 ±1 510 ±0.5 510 ±0.5 Ω

For Emax = 75 t RO 410 ±1 410 ±0.5 410 ±0.5 Ω


6
Insulation impedance Between measuring circuit and housing at 100 VDC RIS >5,000 × 10 Ω

Insulation voltage Between circuit and housing 500 V


(Inteco® only)
Recommended supply voltage To hold the specified performance Bu 4...24 V

Max. supply voltage Permissible for continuous operation without Umax 32 (Ex versions: 25) V
damage
Nominal ambient temp. range To hold the specified performance BT -10 … +40 -10 … +40 -10 … +40 °C

Usable temperature range Permissible for continuous operation without BTu -40 … +95 -40 … +95 -40 … +95 °C
damage
Storage temperature range Without electrical and mechanical stress BTi -40 … +95 -40 … +95 -40 … +95 °C

Material (load cell housing) Stainless steel 1.4301 acc. DIN EN 10088-3 (conforms to 304 AISI)

Permissible eccentricity Permissible displacement from nominal load line Sex For 500 kg … 10 t: 10 mm
For 20 t … 75 t: 5
Vibration resistance Resistance against oscillations 20 g, 100 h, 10 … 150 Hz
(IEC 68-2-6 Fc)
Parameter Description Abbr. PR 6203 D1/N PR 6203 C3 PR 6203 C6 Unit

Barometric pressure influence Influence of barometric pressure on output PKSmin 500 kg … 3 t: 200 g/kPa
5 t … 10 t: 330
20 t … 75 t: 420
Nominal deflection Max. elastic deformation under maximum capacity Snom ≤5 t: ≤0.3/≤20 t: ≤0.5/≤50 t: ≤0.8/ mm
60 t … 75 t: ≤1.2
Protection class according to IEC 529
– Inteco: IP68*/IP69
– Connexx®: IP65 / IP 68**
Cable Length: Emax ≤10 t: 5 m, Emax >10 t: 12 m
Diameter: 5 mm
Cross section: 4 × 0.35 mm2
Material cable sheath: TPE
Bending radius ≥25 mm in case of fixed installation
≥75 mm in case of flexible installation

Connexx®

Nominal ambient temp. range To hold the specified performance BT -10 … +40 °C

Usable temperature range Permissible for continuous operation without BTu -30 … +60 °C
damage
Storage temperature range Without electrical and mechanical stress BTi -30 … +70 °C

 * The load cell can be submerged in water at a depth of 1.5 m for 10,000 hours.
** The module can be submerged in water at a depth of 1.5 m for 100 hours.

Accuracy classes and minimum verification interval, vmin

OIML NTEP Class III Multiple NTEP Class IIIL Multiple


D1/D1E C3/C3E C6/C6E D1/D1E C3/C3E C6/C6E D1/D1E C3/C3E C6/C6E

Maximum number of verification 1,000 3,000 6,000 1,000 5,000 10,000 2,000 10,000 10,000
intervals, nmax
500 kg 0.2 kg n.a. n.a. 0.2 kg n.a. n.a. n.a. n.a. n.a.

1t 0.2 kg n.a. n.a. 0.2 kg n.a. n.a. n.a. n.a. n.a.

2t 0.4 kg 0.2 kg n.a. 0.4 kg 0.2 kg n.a. 0.2 kg 0.2 kg n.a.

3t 0.6 kg 0.22 kg 0.22 kg 0.6 kg 0.22 kg 0.22 kg 0.2 kg 0.2 kg 0.2 kg

5t 1 kg 0.36 kg 0.36 kg 1 kg 0.36 kg 0.36 kg 0.34 kg 0.2 kg 0.2 kg

10 t 2 kg 0.72 kg 0.72 kg 2 kg 0.72 kg 0.72 kg 0.67 kg 0.24 kg 0.24 kg

20 t 4 kg 1.43 kg 1 kg 4 kg 1.43 kg 1 kg 1.34 kg 0.48 kg 0.34 kg

30 t 6 kg 2.15 kg 1.5 kg 6 kg 2.15 kg 1.5 kg 2 kg 0.72 kg 0.5 kg

50 t 10 kg 3.58 kg 2.5 kg 10 kg 3.58 kg 2.5 kg 3.34 kg 1.2 kg 0.84 kg

60 t 12 kg 4.29 kg 3 kg 12 kg 4.29 kg 3 kg 4 kg 1.43 kg 1 kg

75 t 15 kg 5.36 kg 3.75 kg 15 kg 5.36 kg 3.75 kg 5 kg 1.79 kg 1.25 kg


Easy replacement:
All the accessories and mounting kits for the load cell PR 6201 are still
compatible with the Inteco®!

Mounting kit PR 6001

vertical load with-


Lifting destructive
Installation height
Maximum capac-

Mounting screws

Max. permissible

Max. permissible

Max. permissible

Max. permissible

Max. permissible
destructive force

lift-off force (kN)

load for jack-up


(not included in

horizontal force
ity of load cell

according to
Mounting kit/ Description/

out load cell

CE approval
eccentricity
Material

Horizontal

force [KN]
accessories comments

delivery)

EN 1090
Inteco®

(mm)

(kN)

[KN]
Steel electrogal-
Mounting disc
vanised, chromated
PR 6001/00N incl. upper load M12-8.8 20 50 Yes
and sealed (RoHS
disc
compliant) /
Mounting kit
Stainless steel
PR 6001/00S incl. upper and M12-A2-70 20 50 /
1.4301 (AISI 304)
lower load disc
Steel electrogal-
vanised, chromated
PR 6001/10N MaxiFLEXLOCK M12-8.8 45 50 Yes
and sealed (RoHS 190.5 20 ± 5 25 t 1.5 t
500 kg – 10 t

compliant) 25

Stainless steel
PR 6001/10S MaxiFLEXLOCK M12-A2-70 39 50 /
1.4301 (AISI 304)
Steel electrogal-
vanised, chromated
PR 6001/20N MaxiFLEXLOCK M16-8.8 100 50 Yes
and sealed (RoHS
compliant) 50

Stainless steel
PR 6001/20S MaxiFLEXLOCK M16-A2-70 100 50 /
1.4301 (AISI 304)
Steel electrogal- High-load
vanised, chromated mounting kit
PR 6001/30N M20-8.8 250.5 200 236 250 180 ± 5 25 t 1.5 t Yes
and sealed (RoHS incl. upper load
compliant) disc
Steel electrogal-
Mounting kit
vanised, chromated
PR 6001/01N including upper M12-8.8 20 50 Yes
and sealed (RoHS
load disc
compliant) /
Mounting kit
Stainless steel
PR 6001/01S incl. upper and M12-A2-70 20 50 /
1.4301 (AISI 304)
lower load disc
Steel electrogal-
vanised, chromated Yes
PR 6001/11N MaxiFLEXLOCK M12-8.8 45 50
and sealed (RoHS 190.5 30 ± 5 25 t /
compliant) 25

Stainless steel
PR 6001/11S MaxiFLEXLOCK M12-A2-70 39 50 /
20 t – 75 t

1.4301 (AISI 304)
Steel electrogal-
vanised, chromated
PR 6001/21N MaxiFLEXLOCK M16-8.8 100 50 Yes
and sealed (RoHS
compliant) 50

Stainless steel
PR 6001/21S MaxiFLEXLOCK M16-A2-70 100 50 /
1.4301 (AISI 304)
Steel electrogal-
vanised, chromated
PR 6001/26N MaxiFLEXLOCK M20-8.8 50 100 250 Yes
and sealed (RoHS
compliant)
250.5 180 ± 5 25 t /
Steel electrogal- High-load
vanised, chromated mounting kit
PR 6001/31N M20-8.8 200 236 250 Yes
and sealed (RoHS incl. upper load
compliant) disc
Mounting kit PR 6143

Installation height
Maximum capac-

Mounting screws

Max. permissible
destructive force
(not included in

horizontal force

ble lift-off force


Max. permissi-
ity of load cell

according to
Mounting kit/ Description/

CE approval
Material

Horizontal
accessories comments

delivery)

EN 1090
Inteco®

(kN)**
(mm)

(kN)
[KN]
500 kg –
10 t

PR 6143/24S Stainless steel 1.4542 Lower load disc / 70 / / / /


20 t –
75 t

PR 6143/54S Stainless steel 1.4542 Lower load disc / / / / / /

Steel electrogalvanised,
PR 6143/50N chromated and sealed Upper load disc / / / / / /
(RoHS compliant)
PR 6143/50S Stainless steel 1.4542 Upper load disc / / / / / /
Steel electrogalvanised,
MiniFLEXLOCK
500 kg – 75 t

PR 6143/00N chromated and sealed M12-8.8 35 Yes


incl. upper load disc
(RoHS compliant) 25 50
Stainless steel 1.4301  MiniFLEXLOCK incl. upper
PR 6143/00S M12-A2-70 35 /
(AISI 304) and lower load disc*
190.5
Steel electrogalvanised,
MiniFLEXLOCK
PR 6143/10N chromated and sealed M16-8.8 70 Yes
incl. upper load disc
(RoHS compliant) 50 60
Stainless steel 1.4301  MiniFLEXLOCK incl. upper
PR 6143/10S M16-A2-70 70 /
(AISI 304) and lower load disc*

  * Lower load disc only for 0.5 t–10 t,


for 20 t–75 t please order lower load disc PR 6143/54S separately
** With separate threaded bolt of strength class 8.8 or A2-70

Mounting kit PR 6144

vertical load with-


Lifting destructive
Installation height
Maximum capac-

Mounting screws

Max. permissible

Max. permissible
destructive force

lift-off force (kN)


(not included in
ity of load cell

according to

according to
Mounting kit/ Description/

out load cell


CE approval

CE approval
Material
Horizontal

force [KN]

accessories comments
delivery)

EN 1090

EN 1090
Inteco®

(mm)

[KN]

Steel electrogalvanised, Seismic Mount


500 kg –
75 t

PR 6144/54N chromated and sealed incl. load cell M30-8.8 217 370 600 600 400 16 t Yes
(RoHS compliant) dummy

Mounting kit PR 6145


Installation height
Maximum capac-

Mounting screws
(not included in
ity of load cell

according to

Mounting kit/ Description/


CE approval

Material
accessories comments
delivery)

EN 1090
Inteco®

(mm)

Steel electrogalvanised, chromated and sealed (RoHS Plate mounting kit


500 kg – 75 t

PR 6145/00N M12-8.8 Yes


compliant) incl. upper load disc
Plate mounting kit 190.5
PR 6145/00S Stainless steel 1.4301 (AISI 304) incl. upper and lower load M12-A2-70 /
disc*

* Lower load disc only for 0.5 t–10 t,


for 20 t–75 t please order lower load disc PR 6143/54S separately
Fixed bearing PR 6101

Installation height
Maximum capac-

Mounting screws

Max. usable load

destructive force

usable load (kN)


Permissible hor-
(not included in

izontal force for


ity of load cell

Fixed bearing Material

Horizontal
delivery)
Inteco®

(mm)

[KN]
Steel electrogalvanised, chromated and sealed 5t 15
PR 6101/53N M12-8.8 25
(RoHS compliant) 10 t 12
190.5
5t

5t 10
PR 6101/53S Stainless steel 1.4301 (AISI 304) M12-A2-70 16
10 t 8.5

Steel electrogalvanised, chromated and sealed 20 t 45


PR 6101/24N M12-8.8 80
(RoHS compliant) 40 t 35
20 t

190.5
20 t 30
PR 6101/24S Stainless steel 1.4301 (AISI 304) M12-A2-70 40
40 t 20

Steel electrogalvanised, chromated and sealed 50 t 100


PR 6101/54N M12-8.8 250
(RoHS compliant) 75 t 80
75 t

190.5
50 t 50
PR 6101/54S Stainless steel 1.4301 (AISI 304) M12-A2-70 150
75 t 20

Converter Connexx®

Fitted with the converter Connexx®, the load cell


Inteco® offers a whole host of possibilities:
 he digital version guarantees fast signalling
T
times for reliable dosing processes.
 hanks to the use of field bus communication,
T
the cable junction box is no longer needed.
 he standard interface CANopen ensures
T
straightforward installation and calibration.
 ANopen allows for extra-long communication
C
paths of up to 200 m.
 eight values can also be generated individual-
W
ly – per load cell – meaning that defective load
cells can be identified more easily.

All dimensions in mm
Technical diagrams
Load cells Inteco®/PR 6203

Pos. Designation Model b c d e


Spherical Spherical
1 Lower load disc radius radius
2 Support ring Inteco®/500 kg … 3 t 15 150 24 32
®
Inteco /5 t … 10 t 15 150 34 44
®
Inteco /20 t … 75 t 35 220 56 62

Load cell Inteco®

Converter Connexx®

Converter Connexx®

All dimensions in mm