403d 15g Engine
403d 15g Engine
403d 15g Engine
403D-15G
The Perkins® 400 Series engine family continues to set new standards in the
compact engine market. Developed alongside customers to fulfill their needs in the
generator set, compressor, agricultural and general industrial markets.
These ElectropaKs provide compact power, from a robust family of 3 and 4 cylinder
diesel engines designed to provide economic and durable operation at prime and
standby duties, hitting the key power nodes required by the power generation
industry.
Emissions statement
Constant Speed Engines for use in Industrial, IOPU and ElectropaK applications: Certified against the requirements
of EU Stage IIIA (Directives 97/68/EC, as last amended, for mobile applications).
Specification
Number of cylinders 3 vertical in-line
Bore and stroke 84 x 90 mm 3.3 x 3.5 in
Displacement 1.496 litres 91.3 in3
Aspiration Naturally aspirated
Cycle 4 stroke
Combustion system Indirect injection
Compression ratio 22.5:1
Rotation Anti-clockwise, viewed on flywheel
Total lubricating capacity 6.0 litres 1.6 US gal
Cooling system Water cooled
Total coolant capacity 6.0 litres 1.6 US gal
www.perkins.com
Photographs are for illustrative purposes only and may not reflect final specification.
All information in this document is substantially correct at time of printing and may be altered subsequently.
Final weight and dimensions will depend on completed specification.
Publication No. PN1911A/12/14 Produced in England ©2014 Perkins Engines Company Limited
Features and benefits
We provide one-year warranties for constant speed engines and two-year warranties for variable speed models, as
standard. These are supported by multilevel Extended Service Contracts that can be bought additionally
Discover more: www.perkins.esc
Product support
l With highly trained Perkins distributors in thousands of communities in over 180 countries, you are never far away
from expert product knowledge, genuine parts and a range of advanced diagnostic technology for keeping your
engine in peak condition
l To find your local distributor: www.perkins.com/distributor
www.perkins.com
Photographs are for illustrative purposes only and may not reflect final specification.
All information in this document is substantially correct at time of printing and may be altered subsequently.
Final weight and dimensions will depend on completed specification.
Publication No. PN1911A/12/14 Produced in England ©2014 Perkins Engines Company Limited
Technical information
Air inlet
l Mounted air filter
Fuel system
l Mechanically governed cassette type fuel injection pump
l Split element fuel filter
Lubrication system
l Wet steel sump with filler and dipstick
l Spin-on full-flow lub oil filter
Cooling system
l Thermostatically-controlled system with belt driven coolant pump and pusher fan
l Mounted radiator, piping and guards
Electrical equipment
l 12 volt starter motor and 12 volt 65 amp alternator with DC output
l Oil pressure and coolant temperature switches
Mountings
l Front and rear engine mounting bracket
Optional equipment
l Parts book
Option groups
A selection of optional items is available to enable you to prepare a specification precisely matched to your needs.
www.perkins.com
Photographs are for illustrative purposes only and may not reflect final specification.
All information in this document is substantially correct at time of printing and may be altered subsequently.
Final weight and dimensions will depend on completed specification.
Publication No. PN1911A/12/14 Produced in England ©2014 Perkins Engines Company Limited
Typical Engine power
Spee Type of generator Gross Net
d operatio output (Net)
rpm n kVA kWe kWm hp kWm hp
Prime power 13.1 10.4 12.2 16.4 12.0 16.0
1500
Standby power 14.5 11.6 13.5 18.1 13.2 17.6
The above ratings represent the engine performance capabilities to conditions specified in ISO 8528/1, ISO 3046/1:1986, BS 5514/1. Derating
may be required for conditions outside these; consult Perkins Engines Company Limited.
Generator powers are typical and are based on typical alternator efficiencies and a power factor (cos θ) of 0.8. Fuel specification: BS 2869: Part 2
1998 Class A2 or ASTM D975 D2.
Rating definitions: Prime power: Power available at variable load in lieu of a main power network. Overload of 10% is permitted for 1 hour in every
12 hours operation. Standby (maximum): Power available at variable load in the event of a main power network failure. No overload is permitted.
POWERMAX
ADDRESS EMAIL
Bab-e-Arif Apartment, [email protected]
Shop no.A-59, North Karachi. [email protected]
WEBSITE [email protected]
www.powermaxgenerator.com
CONTACT #
+923212010005