MODEL8031: Warning Phase Rotation Tester

Download as pdf or txt
Download as pdf or txt
You are on page 1of 2

INSTRUCTION MANUAL

# WARNING
●Read through and understand instructions contained in this
PHASE ROTATION TESTER manual before starting using the instrument.
●Save and keep the manual handy to enable quick reference
MODEL8031 whenever necessary.
●Be sure to use the instrument only in its intended applications
DESIGNATIONS
and to follow measurement procedures described in the
manual.
●Be sure to understand and follow all safety instructions
contained in the manual. Failure to follow the above
instructions cause injury instrument damage and/or damage
to equipment under test.

The symbol # Indicated on the instrument means that the user


must refer to related parts in the manual for safe operation of the
instrument. Be sure to carefully read instructions following each
# Symbol in this manual.

#WARNING is reserved for conditions and actions that can


cause serious or fatal injury.
#CAUTION is reserved for conditions and actions that can
cause injury or property damage.
SAFETY WARNINGS
Following symbols are used on the instrument and in the
This instrument has been designed and tested according to IEC instruction manual. Attention should be paid to each symbol to
Publication 61010; Safety Requirements for Electronic Measuring ensure your safety.
Apparatus. This Instruction manual contains warnings and
safetyrules which must be observed by the user to ensure safe Refer to this instructions in the manual.
operation of the instrument and retain it in safe condition.
Therefore, read through these operating instruction before using # This
 symbol is marked where the user must refer to the instruction
manual so as not to cause personal injury or instrument
the instrument.
The voltage values used in this manual or on the meter are given damage.
in line voltage, unless otherwise specified.
 Indicates an instrument with double or reinforced insulation.

instrument designed for CAT.Ⅲ environments gives greater


# WARNINGS protection than one designed for CAT.Ⅱ.
1. Never open the instrument when making measurements.
CAT.Ⅰ: Equipment connected to a mains outlet socket
2. If the instrument shows the following conditions, do not try to
CAT.Ⅱ: Fault category level at a mains socket
make measurements and have the instrument checked for
CAT.Ⅲ: Fault category at distribution board level
inspection or repair.
CAT.Ⅳ: The circuit from the service drop to the power meter and
a) Instrument shows visual damage.
primary over-current protection device (distribution
b) Test leads are damaged.
panel).
c) Instrument can not be operated for intended measurements.
d) I nstrument has been stored for a long period of time
under abnormal conditions. Distribution Board CAT.Ⅲ
e) I nstrument has been subjected to severe shocks and
vibrations.
Incoming supply
3. High voltage may be present with high energy levels. Interior wiring
C
 onnect the leads to the system carefully with fingers behind
all finger guards. CAT.Ⅳ
4. If the all open phase lamps are not lit on, any phase may still CAT.Ⅰ Socket
be live-be carefull. CAT.Ⅱ
Socket Equipment
CAT.Ⅱ
# CAUTIONS
1. Make sure to never apply a voltage more than 600V ACrms.
between the test leads of the instrument and earth to avoid
damage to the instrument.
2. Do not measure for more than five minutes when measuring FEATURES
on 500V AC or more, although the instrument is designed for
the use 110V through 500V AC. ●Two Functions in One Unit
 K EW8031F is designed to check phase sequence. Lamps
Measurement categories (Over-voltage categories) provided on the unit will also tell you if a phase is open.
To ensure safe operation of measuring instruments, IEC61010
establishes safety standards for various electrical environments, ●Highly Reliable
categorized as CAT.Ⅰ to CAT.Ⅳ, and called measurement  Can check a wide range of 3-phase power source from 110V to
categories. Higher-numbered categories correspond to 500V. Sealed against dust, the unit ensures trouble-free
electrical environments with greater energy, So a measuring performance.
●Functional Design (3) Make sure that all of the three lamps for phase check are on.
 Small, Lightweight and portable. Designed for maximum ease of If so, there is no open phase. When any of the three lamps is
operation and ruggedness. Not on there is open phase.

●Safety Design Open phase check Open phase on terminal


 N o exposed metal parts. Safety features are incorporated
Lamp "L1" is not on where Red alligator clip
including the instant push button switch operation.
is connected.

Open phase check Open phase on terminal


SPECIFICATIONS
Lamp "L2" is not on where Whight alligator clip
Standard : IEC 61010-1 CAT.Ⅲ 300V Pollution degree 2 is connected.
IEC 61557-1,7
Voltage : 110V to 500V Open phase check Open phase on terminal
Frequency : 50Hz / 60Hz Lamp "L3" is not on where Blue alligator clip
Withstand Voltage : 5,550V AC for one minute
is connected.
Time Limit for Continuous Use : Within 5 minutes in case voltage
is above 500V.
Dimensions : 106 (L) x 75 (W) x 40 (D) mm *When the open phase check lamps are not on the rotating disc
Weight : Approx. 350g does not turn.
Accessories : Instruction Manual, Carrying Case
IP cord : IP30 (IEC60529)
(4) C
 heck the rotating direction of the inside disc through the
phase sequence indication window.
*When the rotating disc turns counter-clockwise alternate the
OPERATING INSTRUCTIONS connection of the two of the three alligator clips. Then, the
rotating disc will turn clockwise.
(1) Connect colour coded alligator clips or prods to the terminals
of a 3-phase power source where a rotating electrical machine *When the rotating disc turns clockwise phase sequence is
such as a motor will be connected or input to a building. L1,L2 and L3 in order of the power source terminals where the
Red, Whight and Blue alligator clips are connected.
(2) Press the push switch button located on top of the unit.
K eep this button pressed during phase sequence or open Please Note : N
 ew European harmonized phase colours are
phase check. When the push switch button is released it as follows.
immediately goes off. Red = Brown   Protective Earth = Green yellow
Whight = Black  Neutral = Blue
Blue = Grey

10-11 92-1400B