Atos - VV Prop TN6 DHZO e TN 10 DKZOR
Atos - VV Prop TN6 DHZO e TN 10 DKZOR
Atos - VV Prop TN6 DHZO e TN 10 DKZOR
a b a b b b a a
F160
3 MAIN CHARACTERISTICS OF PROPORTIONAL DIRECTIONAL VALVES TYPE DHZO-A* AND DKZOR-A*
B Power supply zero Filtered and rectified: Vrms = 21 ÷ 33 (ripple max 2Vpp)
C Signal zero Reference 0 VDC Reference 0 VDC Enabling input normal working 9 ÷ 24 VDC
D Input signal + 0 ÷ 10 VDC (for single solenoid valve) 0 ÷ 10 VDC (for single solenoid valve)
4 ÷ 20 mA
E Input signal - ± 10 VDC (for double solenoid valve) ± 10 VDC (for double solenoid valve)
Monitor 0 ÷ 5 VDC (for single solenoid valve) 0 ÷ 5 VDC (for single solenoid valve)
F ± 5 VDC (for double solenoid valve) ± 5 VDC (for double solenoid valve)
driving current 1V = 1A (referred to pin C) 1V = 1A (referred to pin B)
G Earth Connect only when the power supply is not conform to VDE 0551 (CEI 14/6)
Note:
COMMUNICATION CONNECTORS (for -AES)
- electrical signals (e.g. actual - feedback signals) acquired via valve electro-
Communication -PS (RS232) -BC (CAN Bus) -BP (PROFIBUS-DP) nics must not be used to switch off the machine safety functions. This is in
options male connector male connector female connector (reverse key) accordance with the European standards (Safety requirements of fluid tech-
NC CAN_SHLD +5V nology systems and components - hydraulics, EN-892).
1 Not Connected Shield Termination voltage
- installation notes with basic information for commissioning and start-up, are
always supplied with relevant components, together with the specific technical
NC NC LINE -A tables.
Signal description
2
Not Connected Not Connected Bus line (high)
Pin number
CONNECTOR CODE SP-666 SP-ZH-7P (1) SP-ZM-7P (1) SP-ZH-12P (1) SP-ZH-5P (1) SP-ZH-5P/BP (1)
CONNECTOR CODE IP65 IP67 IP66 IP65 IP67 IP67
(1) to be ordered separately
5 PROGRAMMING DEVICES
The functional parameters of the digital valves, as the bias, scale, ramp and linearization of the regulation characteristic, can be easily set and optimized with
graphic interface by using the following software programming devices suitable for standard PC:
KIT-E-SW-PS for electronics with RS232 interface (option -PS)
KIT-E-SW-BC for electronics with CANbus interface (option -BC)
KIT-E-SW-BP for electronics with PROFIBUS-DP interface (option -BP)
see tab. G500 for complete information about the programming device kits and for the PC minimum requirements.
Only for the -BC and -BP communication options, the functional parameters can be alternatively set via fieldbus through the machine control unit, using the stan-
dard communication protocol implemented by Atos.
The protocol operating instructions to be implemented in the standard protocols (DS301V4.02, DSP408 for CANbus and DPVO for PROFIBUS-DP) are described in
the user manuals MAN-S-BC (for -BC option) and MAN-S-BP (for -BP option) supplied with the relevant programming device kits.
The above programming devices have to be ordered separately.
6 DIAGRAMS FOR DHZO (based on mineral oil ISO VG 46 at 50 °C)
4
Note: 1
1) For the valves with digital electronics, 6
the regulation characteristic can be modified
by setting the internal software parameters,
see tab. G500.
Reference signal 0 ÷-10 V PB/AT X = Threshold for bias activation depending to the valve type and amplifier type
4÷12 mA (also for option /B)
1 = spool L14
2 = spool L1
3 = spool L3, S3, D3 2 4
4 = spool L5, S5, D5
3
F160
7 DIAGRAMS FOR DKZOR (based on mineral oil ISO VG 46 at 50 °C)
1 = spool L3, S3
2 = spool L5, S5, D5
1 2
Mounting surface
ISO 4401-AB-03-4 size 06
Fastening bolts: 4 socket head screws M5 x 50 P = PRESSURE PORT
Seals: 4 OR 108; 1 OR 2025 A, B = USE PORT
Diameter of ports A, B, P, T: Ø 7,5 mm (max) T = TANK PORT
Diameter of port Y: Ø = 3,2 mm (only for /Y option) Y = DRAIN PORT (see note)
V = AIR BLEED-OFF
DHZO-A-05 DHZO-A-07
DHZO-AE-05 DHZO-AE-07
DHZO-AES-*-05 DHZO-AES-*-07
option /Z
option /Z
10 MOUNTING PLATES FOR DHZO (select /Y in the plate model code for valves with option /Y)
Ø Counterbore
Gas ports Mass
Size Model Ports location [mm]
[kg]
A, B, P, T (X, Y) A, B, P, T (X, Y)
BA-202 Ports A, B, P, T underneath; 3/8" – 1,2
06 BA-204 Ports P, T underneath; ports A, B on lateral side 3/8" 25,5 1,8
BA-302 (/Y) Ports A, B, P, T (X, Y) underneath; 1/2" (1/8") 30 (16,5) 1,8
F160
11 INSTALLATION DIMENSIONS FOR DKZOR [mm]
Mounting surface
ISO 4401-AC-05-4 size 10
Fastening bolts: 4 socket head screws M6 x 40
Seals: 5 OR 2050; 1 OR 108 P = PRESSURE PORT
Diameter of ports A, B, P, T: Ø 11,2 mm (max) A, B = USE PORT
Diameter of port Y: Ø = 5 mm (only for /Y option) T = TANK PORT
Y = DRAIN PORT (see note)
V = AIR BLEED-OFF
V
DKZOR-A-15 DKZOR-A-17
DKZOR-AE-15 DKZOR-AE-17
DKZOR-AES-*-15 DKZOR-AES-*-17
option /Z option /Z
13 MOUNTING PLATES FOR DKZOR (select /Y in the plate model code for valves with option /Y)
Ø Counterbore
Gas ports Mass
Size Model Ports location [mm]
[kg]
A, B, P, T (X, Y) A, B, P, T (X, Y)
BA-308 (/Y) Ports A, B, P, T (X, Y) underneath; 1/2" (1/4") 30 (21,5) 2,5
10 BA-428 (/Y) Ports A, B, P, T (X, Y) underneath; 3/4" (1/4") 36,5 (21,5) 5,5
BA-434 (/Y) Ports P, T (X, Y) underneath; A, B on lateral side 3/4" (1/4") 36,5 (21,5) 8,5
11/05