MSR125H/HP: Description

Download as pdf or txt
Download as pdf or txt
You are on page 1of 3

MSR125H/HP

Description

The Allen-Bradley Guardmaster Minotaur MSR125H/HP is a logic unit for monitoring and interfacing two-hand control devices with a
safety-related circuit. The MSR125H/HP is for use with mechanical switches and the Rockwell Automation Bulletin 800Z Zero-Force
Touch Buttons.

The MSR125H/HP has two normally open safety outputs. The safety outputs have independent and redundant internal contacts to
support the safety function.

The MSR125H/HP requires the two switches to be operated within 0.5 seconds of each other and will only authorize the ON state
while both switches are held down. If one of the switches is released, the output goes to the OFF state and the machine cannot be
restarted until both buttons are released and then operated simultaneously.

The MSR125H/HP conforms to EN 574 Category IIIC, which gives specific requirements for two-hand control units and logic devices.

The MSR125H has fixed terminals and the MSR125HP has removable terminals.

Features

Category 4 per EN 954-1


Safety category IIIC per EN 574
Two-hand control unit
Two N.O. safety outputs
Fixed or removable terminals
22.5 mm wide housing

LED Indicators

Green Power on

Green CH1 Output Active

Green CH2 Output Active

Specifications
Safety Ratings

Standards EN 574, EN 954-1, ISO 13849-1, IEC/EN 60204-1, IEC 60947-4-1, IEC 60947-5-1, ANSI B11.19, AS 4024.1

Safety Classification Cat. 4 per EN 954-1 (ISO 13849-1), SIL CL3 per EN IEC 62061, PLe per ISO 13849-1

Functional Safety Data ⋆ PFHD : < 1.44 x 10-9


Note: For up-to-date information, visit
MTTFd: > 385 years
http://www.ab.com/safety/
Suitable for performance levels Ple (according to ISO 13849-1:2006) and for use in SIL3 systems (according to IEC 62061) depending on the
architecture and application characteristics

Certifications CE Marked for all applicable directives, cULus, c-Tick, and BG

Power Supply

Input Power Entry 24V DC, 24V AC, 115V AC, 230V AC

Power Consumption 2W

Inputs

Safety Inputs 1 N.C. + 1 N.O.

Input Simultaneity <0.5 sec

Input Resistance, Max. 40 W

Reset Automatic

Power On Delay/ 1 second/500 ms


Recovery Time

Response Time 20 ms

Outputs

Safety Contacts 2 N.O.

Thermal CurrentIlth 1 x 6 A or 2 x 4 A nonswitching

Rated Impulse withstand Voltage 2500V

Switching Current @ Voltage, Min. 10 mA/10V

Fuses, Output External 6 A slow blow or 10 A fast acting

Electrical Life (Operations) (With surge suppression)


250V AC/6 A/1500VA cosf = 0.35…0.1 M
250V AC/2.5 A/625VA cosf = 0.6…0.5 M
250V AC/1.5 A/375VA cosf = 0.35…0.3 M
250V AC/5 A/1250VA cosf = 0.6…0.1 M
24V DC/2 A/48 W = 1 M
10V DC/0.01 A/0.1 W = 2 M

Mechanical Life 2,000,000 operations

Utilization Category

Resistive: AC-1 8 A @ 250V AC

Resistive: DC-1 6 A/24V DC

Inductive: AC-15 6 A @ 250V AC 6 A @ 125V AC

Inductive: DC-13 3 A/24V DC 6 A/24V DC @ 6 ops/min

Resistive UL: B300, R300, 8 A/250V AC, 6 A/24V DC, 30V DC Resistive

Environmental and Physical Characteristics

Enclosure Type Rating/ IP40 (NEMA 1), DIN 0470/


Terminal Protection IP20, DIN 0470

Operating Temperature [C (F)] ‐5…+55 ° (23…131 °)

Vibration 10…55 Hz, 0.35 mm

Shock 10 g, 16 ms, 100 shocks

Mounting 35 mm DIN Rail

Weight [g (lb)] 24V DC: 210 (0.46); 115/230V AC: 260 (0.57)

Conductor Size, Max. 0.2…4 mm2 (24…12 AWG)

⋆ Usable for ISO 13849‐1:2006 and IEC 62061. Data is based on the following assumptions:
- Mission time/Proof test interval of 20 years

Product Selection
Inputs Button Type Safety Outputs Terminals Reset Type Power Supply Cat. No.
1 N.C. + 1 N.O. (Two-Hand Control) Mechanical or Bulletin 800Z 2 N.O. Removable (MSR125HP) Automatic 24V DC 440R-D23171

24V AC 440R-D23170

115V AC 440R-D23169

230V AC 440R-D23168

Fixed (MSR125H) 24V DC 440R-D23166

115V AC 440R-D23164

230V AC 440R-D23163

Accessories

Description Cat. No.


Bag of 4, 4-Pin Screw Terminal Blocks 440R-A23209

Bag of 4, 4-Pin Spring Clamp Terminal Blocks 440R-A23228

Approximate Dimensions

Dimensions are shown in mm (in.). Dimensions are not intended to be used for installation purposes.

Block Diagram

Typical Wiring Diagrams

Two-Hand Control, Dual Channel, Auto Reset, Two-Hand Control, Dual Channel, Auto Reset,
Output Monitoring No Output Monitoring