Df902a 12KV

The document describes the Model DF902A 12KV Capacitance & Dissipation Factor Test Set. It is designed to measure dissipation factor and power factor in environments with electromagnetic interference. It can test components such as transformers, capacitors, circuit breakers and more. Key features include automatic operation, high accuracy even in noisy environments, multiple measurement functions, and rugged design for field use. Test results include capacitance, dissipation factor, resistance and other parameters.

Uploaded by

Ronald H Santos
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
134 views2 pages

Df902a 12KV

The document describes the Model DF902A 12KV Capacitance & Dissipation Factor Test Set. It is designed to measure dissipation factor and power factor in environments with electromagnetic interference. It can test components such as transformers, capacitors, circuit breakers and more. Key features include automatic operation, high accuracy even in noisy environments, multiple measurement functions, and rugged design for field use. Test results include capacitance, dissipation factor, resistance and other parameters.

Uploaded by

Ronald H Santos
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 2

Model DF902A 12KV

Capacitance & Dissipation


Factor Test Set

Description:

Model DF902A Automatic 12kV Capacitance & Dissipation Factor Test Set is designed to measure dissipation(
Dielectric Loss factor/DF/tgδ) or power factor(PF/cosφ ) in heavy electromagnetic interference environment such
as in power plants or substations.
Together with one special oil cell/cup( for option), oil dissipation also can be measured.
Its main specimens: Power transformer, Distribution transformer, Instrument transformer, Bushings, circuit
breakers, Surge arrestors, capacitors, Motors and Generators.
Its test capabilities: Dielectric Loss factor/DF/tgδ, Power factor(PF/cosφ),Capacitance,etc.

Product Features:

Fully automatic, easy to use; High speed A/D converters, processed by a DSP.
All-in-one structure, lightweight, rugged & compact, self-calibrating, accuracy standard capacitor, ensure
true portability; Model DF902A high accuracy;
High noise suppression based on the frequency All the input resistance is less than 2 Ohm, the
conversion and digital filter technique, its test attached capacitance of connection cable is
accuracy can be ensured even the ratio of negligible;
interference current to specimen current is Using an external high voltage power supplies over
2:1(200%); 12kV or 5A;
Model DF902A has multiple functions:UST / GST 100 groups of data storage. RS232 is available;
/GSTg, all these functions with its main unit; Micro-Printer inside;
Designed for various work environments, in the field, Ultra long life cycle, average 10 years.
in the laboratory;

www.xaapt.com
Specifications:
Multi-Protections:
Output protection against the specimen is short Accuracy:
circuit, broken down; Cx ±(reading×1%+1pF)
Input protection against power supply unstable, DF tgδ ±(reading×1%+0.00040)
broken suddenly,380V supply; PF cosφ ±(reading×1%+0.00040)
Grounded protection. The instrument can’t be Capacitance Range:
operated if its grounding is not reliable; Internal HV 3pF~60000pF / 12kV,60pF~1uF/0.5kV
Fault protection by confirmation, alarm and all External HV 3pF~0.3uF/12kV
parameters displayed; Resolution 0.001pF, 4 digitals
Voltage Overshoot Protection. tgδ Range:
0-100%, Resolution 0.001% (C/L/R specimen is
automatic recognized)

The results: Input current range:


10μA~5A
Internal HV:
0.5~12kV / 200mA (max)
Type of specimen Results Type of specimen Accuracy: ±(1.5×reading×1%+10V)
Capacitive Cx, tgδ, U, I, φ, P, F, t If |tgδ|>1 or |Q|<1, they
will be replaced by Rx. Control mode: Rise or fall smoothly
Inductive Lx, Q, U, I, φ, P, F, t For inductor Rx is always
considered as serial Frequency: 45Hz, 50Hz, 55Hz, 60Hz, 65Hz single
Resistive Cx(Lx), Rx, U, I, φ, P, F, t model. frequency
The results for different type of specimen (C/L/R) 49Hz/51Hz, 59Hz/61Hz dual frequency
External HV:
Cx: Capacitance [1μF=1000nF / 1nF=1000pF] UST: 5A max, GST: 12kV/5A max, 38-72Hz
tgδ: Dissipation Factor [1%=0.01] Oil Cup for option:
Lx: Inductance [1MH=1000kH / 1kH=1000H] 2000V, 90℃,15ml
Q: Quality Factor Test Time:
Rx: Resistance [1MΩ=1000kΩ / 1kΩ=1000Ω] 30s typical (may vary in different test mode)
U: Test voltage [1kV=1000V / 1V=1000mV] Power Supply:
I: Specimen current [1A=1000mA / 1mA=1000μA] 180V~270V,50Hz/60Hz±1%
φ: Phase that current in advance to voltage [°] ( Single phase power supply or generator )
P: Dissipation power [1kW=1000W / 1W=1000mW] Display:
F: Frequency [Hz], double frequency mode is the 128×64 dot matrix
averaged frequency Printer:
t: Temperature [℃], internal sensor may be Thermal printer
influenced by internal heat, all data is at the current Communication Port:
temperature, without calibration. RS-232
Interference:
Ratio of interference current to specimen current is
2:1 ( 200% )
Operating Temperature:
-10℃~60℃
Storage Temperature:
-20℃~60℃
Humidity:
<90% non-condensing
Dimensions:
Accessories included
460mm(L)×350mm(W)×340mm(H),Weight: Main
unit: 23kg , cable: 3.5kg

Tel:0086-29-88897866 Fax:0086-29-82526199
E-mail:[email protected]
www.xaapt.com
Registered to ISO9001-2008
Subject to change without notice