Quadrasorb: Surface Area & Pore Size Analyzer
Quadrasorb: Surface Area & Pore Size Analyzer
• Each of the analysis ports includes RTD coolant level sensor to maintain a constant,
small cold-zone for maximum sensitivity. Long life Dewar flasks for measurements
exceeding 30 hours.
• Each analysis port can be independently programmed with different analyses and
measurement conditions and new samples can be started on each port as prior
measurements are completed with little, or no, delay to other samples already
in progress.
• Choose from two measurement techniques: Patented NOVA helium-free method and
classical helium void-volume method. Designed for analyses using many different gases,
including nitrogen, argon, carbon dioxide, krypton, etc.
• Multiple gas dosing methods to optimize analysis time and resolution: 1. MaxiDose ™
automatically adjusts dose size in response to sample demand; 2. Constant Dose Volume
(0.1 - 10 cc per data point); and 3. Delta Volume™ which adds data points in regions
of large uptake so critical pore filling is never missed.
• Performs krypton gas sorption measurements for very low surface area determination,
eg. pharmaceutical actives, powdered metals, etc. on any or all samples stations.
• Capable of low pressure adsorption data (as low as 4 x 10-5 P/Po) necessary for
more complete characterization of microporous materials, eg. zeolites, activated
carbons, molecular sieves, etc.
QUADRASORB SI
™
TM
QuadraWin - Software
State-of-the-art
The QuadraWin software is powerful and user friendly.
Automated, independent
QuadraWin is superior for data reduction, incorporat-
dewar elevators ing the latest DFT (Density Functional Theory)
models. The software guides you through analysis
setup, data reduction, graphs and report printouts.
Communication port for PC During operation one can view the accumulated data,
control via Windows®-based the isotherm and all associated graphs and analyti-
software
cal results up to that point. After a run, reports and
graphs are printed automatically or you can use the
software to determine the best fitting method, to
Lower front panel opens to compare data by overlaying curves or to adjust graph,
provide unrestricted access for
Dewar placement, maintenance size, scaling, titles, plot markers and line colors for best
and clean-up print out.
Analysis Specifications
Transducer Accuracy: 0.11% full scale (1000 torr transducer) each
manifold/sample station
Separate temperature control All ports at All ports at Yes - with Yes - with independent
for each sample port: same temperature same temperature independent ovens heating mantles
www.quantachrome.com
Trademarks and registered trademarks are
Quantachrome Instruments' quality the property of their respective owners.
management system is certified to be
Quantachrome Instruments Application Laboratory. in accordance with ISO9001:2000.
Our policy of continuous development may cause the information and specifications contained herein to change without notice or liability. © 2008 Quantachrome Corporation 0408 07160 Rev.B