Siprotec 5 Configuration Feb 2, 2021 2:14 PM

The document is a configuration summary for a 7SJ82 Overcurrent protection device. It lists the product code, firmware version, housing details, I/O modules, communication options, and available protection functions. The device has 23 binary inputs, 16 binary outputs, 4 current transformers, 4 voltage transformers, and supports protocols like IEC 61850, IEC 60870-5-104, and DNP3. It has a base function point class of 75 points and supports functions like overcurrent, voltage, frequency, and differential protection.

Uploaded by

ade rohman
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
447 views7 pages

Siprotec 5 Configuration Feb 2, 2021 2:14 PM

The document is a configuration summary for a 7SJ82 Overcurrent protection device. It lists the product code, firmware version, housing details, I/O modules, communication options, and available protection functions. The device has 23 binary inputs, 16 binary outputs, 4 current transformers, 4 voltage transformers, and supports protocols like IEC 61850, IEC 60870-5-104, and DNP3. It has a base function point class of 75 points and supports functions like overcurrent, voltage, frequency, and differential protection.

Uploaded by

ade rohman
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 7

SIPROTEC 5

Configuration
Feb 2, 2021 2:14 PM

Device: 7SJ82 Overcurrent protection

Product code
Short: P1J42389
Long: 7SJ82-DAAA-AA0-0AAAA0-AG0411-12111B-BAA000-000AB0-HB1BD4-JA0

Firmware: Current version


Housing width: 1/3 x 19''
Housing type: Flush mounting
Binary inputs: 23
Binary outputs: 16 Standardrelays
Current transformers: 4 for protection
Voltage transformers: 4 standard
Measuring-transducer inputs: 0 (20 mA or 10 V, fast)
0 (20 mA, standard)
CPU: CP100
Modules in 19" row 1: IO102 , PS101 , IO110
Modules in 19" row 2:
LEDs/Push-buttons: 16 LEDs
Operation Panel: Integrated
Key switch: Without
Display type: Small display
Front Design: Standard
Power Supply: DC 110 V-250 V, AC 100 V-230 V

Communication/Plug-in modules:
Communications encryption: Normal
Integrated Ethernet port J: for DIGSI 5
Plug-in module position E: ETH-BB-2FO: 2x optical Ethernet 100 Mbit/s, 1300 nm, duplex LC connector,
2 km over 50/125 um or 62.5/125 um multimode optical fiber Communication
Protocols: applicable for DIGSI 5, IEC 61850-8-1 MMS and GOOSE, IEC
60870-5-104, DNP3 TCP, Modbus TCP, Synchrophasor (IEEE C37.118 - IP),
Profinet IO, SUP, DHCP, SNTP, SNMP, etc. Redundancy protocols: Line Mode,
RSTP, HSR, PRP
Plug-in module position F: Port is available but not assembled
SIPROTEC 5
Configuration
Feb 2, 2021 2:14 PM

Functions:
Function points class: Base + 75 function points

Note on function-points class


The function-points class results from the sum of the function points of the selected functions. You can apply these
functions as selected. The device allows also each other selection of functions as long as the sum of the required
function points is within the selected function-points class. With the maximum function-points class of 1400 it is
possible to activate all the functions in the device. The function-points exceeding 1400 are free of charge. In the
engineering phase DIGSI 5 checks that the selected configuration is suitable (capable of running in the device) before
loading it to the device.

Miscellaneous:
Warranty: 5 years
Firmware: Current version
SIPROTEC 5
Configuration
Feb 2, 2021 2:14 PM

Functional scope 7SJ82 Overcurrent protection:


Always Add selected Result
ANSI Function Abbr. included Qty. x Value = Points Qty.
Protection functions for 3-pole tripping 3-pole

24 Overexcitation protection V/f x 25 =


25 Synchrocheck, synchronization function Sync x 50 =
25 Synchrocheck, synchronization function Sync x 80 =
with balancing commands (from V7.82)
27 Undervoltage protection: "3-phase" V< x 5 =
or "positive-sequence system V1" or
"universal Vx"
27R, Rate-of-voltage-change protection (from dV/dt x 5 =
59R V8.30)
Undervoltage-controlled reactive power Q>/V< x 15 =
protection
32, 37 Power protection active/reactive power P<>, x 10 =
Q<>
32R Reverse-power protection - P< x 5 =
37 Undercurrent I<

38 Temperature supervision >

46 Negative-sequence overcurrent I2>


protection
46 Unbalanced-load protection (thermal) I2² t>

46 Negative-sequence overcurrent I2>, x 10 =


protection with direction (V2,I2)
47 Overvoltage protection: "negative- V2>; V2/ x 5 =
sequence V2" or "negativ-sequence V2/ V1>
positiv-sequence V1"
49 Thermal overload protection , I²t

49 Thermal overload protection, user- , I²t


defined characteristic
49 Thermal overload protection for RLC , I²t x 10 =
filter elements of a capacitor bank
50/51 Overcurrent protection, phases I> 2x x 30 = 2x
TD
Instantaneous tripping at switch onto SOTF
fault
SIPROTEC 5
Configuration
Feb 2, 2021 2:14 PM

Functional scope 7SJ82 Overcurrent protection:


Always Add selected Result
ANSI Function Abbr. included Qty. x Value = Points Qty.
50HS Instantaneous high-current tripping I>>>

50/51 Overcurrent protection with positive- I1>


TD sequence current I1 (from V7.9)
50N/ Overcurrent protection, ground IN>
51N TD
50N/ Overcurrent protection, 1-phase IN>
51N TD
50Ns/ Sensitive ground-current detection INs>
51Ns for systems with resonant or isolated
neutral systems incl. a) 3I0>, b)
admittance Y0>, c) 3I0-harm> (from
V7.8)
Ground-fault detection via pulse pattern IN-pulse x 15 =
detection; Note: this stage additionally
requires the function 50Ns/51Ns or
67Ns "Sensitive ground-fault detection
for systems with resonant or isolated
neutral"
Intermittent ground-fault protection Iie> x 20 =
50/51 Overcurrent protection for RLC filter I> x 10 =
TD elements of a capacitor bank
50BF Circuit-breaker failure protection, 3-pole CBFP x 5 =
50RS Circuit-breaker restrike protection CBRS x 20 =
51V Overcurrent protection, voltage t=f(I,V) x 10 =
dependent
59, 59N Overvoltage protection: "3-phase" V> x 5 =
or "zero-sequence system V0" or
"universal Vx"
59C Peak overvoltage protection, 3-phase, V> cap. x 30 =
for capacitors
60C Current-unbalance protection for Iunbal> x 50 =
capacitor banks
60 Voltage-comparison supervision U> x 5 =
67 Directional overcurrent protection, I>, (V,I) x 15 =
phases
67N Directional overcurrent protection, IN>, (V,I) x 15 =
ground
SIPROTEC 5
Configuration
Feb 2, 2021 2:14 PM

Functional scope 7SJ82 Overcurrent protection:


Always Add selected Result
ANSI Function Abbr. included Qty. x Value = Points Qty.
67Ns Dir. sensitive ground-fault detection x 30 =
for systems with resonant or isolated
neutral incl. a) 3I0>, b) V0>, c) Cos-/
SinPhi, d) Transient ground-fault fct., e)
Phi(V,I), f) admittance
Directional stage with a harmonic; (V0h,I0h) x 10 =
Note: this stage additionally requires
the function "67Ns Dir. sensitive
ground-fault detection for systems with
resonant or isolated neutral"
Directional intermittent ground-fault Iie dir> x 20 =
protection
74TC Trip-circuit supervision TCS

74CC Closed-circuit supervision (from V7.9) CCS

79 Automatic reclosing, 3-pole AR x 35 =


81 Frequency protection: "f>" or "f<" or "df/ f<>; df/ x 5 =
dt" dt<>
81U Underfrequency load-shedding f<(UFLS) x 15 =
Vector-jump protection > x 20 =
86 Lockout

87N T Restricted ground-fault protection IN x 15 =


87C Differential protection, capacitor bank I x 95 =
90V Automatic voltage controller for two- x 150 =
winding transformer
90V Automatic voltage controller for two- x 180 =
winding transformer with parallel
operation
Number of two-winding transformers 2x x 5 = 2x
with parallel operation (Note: only
together with the function "Automatic
voltage controller for two-winding
transformer with parallel operation")
FL Fault locator, single-sided FL-one x 25 =
FL Fault locator plus (from V7.9) FL plus x 45 =
PMU Synchrophasor measurement PMU x 40 =
SIPROTEC 5
Configuration
Feb 2, 2021 2:14 PM

Functional scope 7SJ82 Overcurrent protection:


Always Add selected Result
ANSI Function Abbr. included Qty. x Value = Points Qty.
AFD Arc-protection (only with plug-in module
ARC-CD-3FO)
Measured values - standard

Measured values - extended: Min, Max, x 3 =


Avg
Switching statistic counters

PQ-Basic measured values: THD (Total


Harmonic Distortion) and harmonics
(from V8.01) THD voltage aggregation
values (from V8.40)
PQ-Basic measured values: Voltage x 20 =
unbalance (from V8.40)
PQ-Basic measured values: Voltage x 30 =
variations - voltage dips, swells and
interruptions (from V8.40)
PQ-Basic measured values: TDD - x 10 =
Total Demand Distortion (from V8.40)
CFC (Standard, control)

CFC arithmetic x 40 =
Circuit-breaker wear monitoring Ix, I²t, 2P x 10 =
Switching sequences function

Inrush current detection

External trip initiation

Control

Circuit-breaker 4x x 3 = 4x
Disconnector/Grounding switch 4x x 3 = 4x
Fault recording of analog and binary
signals
Monitoring and supervision

Protection interface, serial

Frequency-tracking groups (from V7.8)

Cyber Security: Role-Based Access x 25 =


Control (from V7.8)
SIPROTEC 5
Configuration
Feb 2, 2021 2:14 PM

Functional scope 7SJ82 Overcurrent protection:


Always Add selected Result
ANSI Function Abbr. included Qty. x Value = Points Qty.
Temperature acquisition via
communication protocol
Cyber Security: IEEE 802.1x based x 10 =
network authentication (from V8.3)
Sum: 0