This document provides information about the WT4G wind turbine generator model: 1. The WT4G is a type 4 wind turbine model with a full converter interface to the network. 2. It implements controls for high voltage reactive current management and low voltage active current management to enforce voltage limits. 3. The implementation of the rrpwr rate limit was changed on October 21, 2019 to apply the absolute value limit in the direction of the present sign of the active current Ip.

Uploaded by

Manuel
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
72 views1 page

Machine Model WT4G

This document provides information about the WT4G wind turbine generator model: 1. The WT4G is a type 4 wind turbine model with a full converter interface to the network. 2. It implements controls for high voltage reactive current management and low voltage active current management to enforce voltage limits. 3. The implementation of the rrpwr rate limit was changed on October 21, 2019 to apply the absolute value limit in the direction of the present sign of the active current Ip.

Uploaded by

Manuel
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 1

Machine Model WT4G

Model WT4G
Type 4 Wind Turbine with Full Converter Model

High Voltage Reactive Current Management


𝐼𝐼𝑄𝑄
1
𝐸𝐸𝑄𝑄𝑄𝑄𝑄𝑄𝑄𝑄 -1 ∑
1 + 𝑠𝑠𝑇𝑇𝑑𝑑 1 +
+ Norton
𝐼𝐼𝑞𝑞𝑞𝑞𝑞𝑞𝑞𝑞𝑞𝑞𝑞𝑞 Equivalent
Interface to
WT4E 𝐼𝐼𝑞𝑞𝑞𝑞𝑞𝑞𝑞𝑞𝑞𝑞𝑞𝑞 is calculated in network equations network
Model if LPVLSW = 0 then ignore this limit solution to enforce high voltage limit equations
LVPL 𝑉𝑉𝑇𝑇 ≤ 𝑉𝑉𝑉𝑉𝑉𝑉𝑉𝑉
𝑗𝑗𝐼𝐼𝑟𝑟𝑟𝑟𝑟𝑟𝑟𝑟
Rup
1 𝐼𝐼𝑃𝑃 +
𝐼𝐼𝑃𝑃𝑃𝑃𝑃𝑃𝑃𝑃+ ∑ 𝐼𝐼𝑟𝑟𝑟𝑟𝑟𝑟𝑟𝑟
_ 𝑠𝑠𝑇𝑇𝑑𝑑 2
Rdown 1

VT π
Lvpnt0 Lvpnt1

Lvpl1 Low Voltage Active Current Management


1
1 + 𝑠𝑠𝑇𝑇𝐿𝐿𝐿𝐿𝐿𝐿𝐿𝐿 VT
V 3
xerox brkpt States:
1 – Eq
Implementation of the rrpwr Rate Limit (Changed 10/21/2019) 2 – Ip
The parameter rrpwr represents an absolute value rate limit. It applies in the
direction of the present sign of Ip. Thus it can be written as follows
3 – Vmeas
If Ip >= 0 then Rup = +rrpwr Else Rup = +Infinity
If Ip <= 0 then Rdown = -rrpwr Else Rdown = -Infinity