WMF 1100S: Event-& Failure List
WMF 1100S: Event-& Failure List
9013 2 Switch coffee machine off and Brewer motor Encoder or cable defective. Check encoder / cable
on again. In case of error, Encoder error
please call service!
9017 2 Switch coffee machine off and Standardizing error brewer Brewing chamber not empty. Switch machine off and on again
on again. In case of error, motor. Always after turn on the Ground coffee or mechanical
please call service! machine the Standardiization will reason (stiff)
done
9042 1d Please wait, boiler is filled with Beverage lockout at low water Water is refilled
water, beverage dispensing is
blocked!
9053 1a Cleaning required Machine should be cleaned Cleaning prompt by default 26 h. Carry out cleaning.
Beverage dispensing is not
blocked.
9055 1c Forced cleaning The machine must be cleaned Limit time reached or cleaning Carry out cleaning.
has been interrupted. Machine
must be cleaned. Dispensing of
coffee beverages blocked.
9063 1b [graphic] Power input of grinder below idle Beans empty. Idle current level Refill beans, carry out idle
current level. wrong current calibration
9064 1b [graphic] Power input of grinder below idle Beans empty. Idle current level Refill beans, carry out idle
current level. wrong current calibration
Service Error Display Text (E) Error Description Reason Solution
Errorcode Category
9068 1c [graphic] Grounds container not inserted Grounds container removed or Reinsert grounds container,
grounds container/grounds check grounds container resp.
container switch defective. grounds container switch
9069 1c [graphic] Grounds container is full. Filling counter has reached full Empty grounds container.
level. Grounds container must be
removed longer than minumum
emptying time.
9070 1a [graphic] Grounds container will be full Filling counter has reached Empty grounds container.
Empty grounds container soon soon. Message can be warning level and will be full
confirmed and further beverages after only few brewings.
can be dispensed.
9071 1c Empty grounds container External grounds container is Filling level of the external Empty external grounds
full. grounds container has exceeded container
the max. filling level.
9072 1d Manual insert open Tablet insert / Manual insert has Tablet insert / Manual insert has Close tablet insert / manual
Please close manual insert been opened during beverage been opened; reed sensor insert; check reed sensor or
dispensing defective or magnet missing magnet resp. change them
9073 1d Insert ground coffee, close Manual insert lid has been Fill in ground coffee powder,
manual insert and select opened. Coffee can be brewed close manual insert and press
beverage with ground coffee powder which beverage button
must be inserted through the
manual insert.
Service Error Display Text (E) Error Description Reason Solution
Errorcode Category
9077 2 Leakage water detected. Leakage water detected. e.g. valve leaky due to chips of Repair leakage
Switch coffee machine off and scale
on again. In case of error,
please call service and close
water supply!
9078 3b Water filter exhausted, please (Set) filter capacity has been (Set) filter capacity has been Exchange water filter
exchange reached reached
9082 1b Milk in milk cooler too warm. Set temperature level of milk Warm milk has been refilled Wait or exchange milk.
Dispensing of milk beverages control is reached
not recommended!
9083 1b Attention, cooler temperature is Lower temperature level of milk Milk cooler temperature is set Re-adjust cooler temperature
in freeze zone! In case of icing control is reached (beverages too low
please consult user manual. can still be dispensed)
9084 1c [graphic] Water tank is removed or empty. Water tank is removed or empty; Fill and reinsert water tank;
Fill water tank tank sensor is defective. check tank sensor
9091 3b [graphic] Service brewer due Number of brewings reached Exchange brewer
Service brewer due. Please
change brewer
9092 3b [graphic] Descaling due Without water filter: Water flow Carry out descaling.
Descaling due. Please carry out capacity according to the set
descaling water hardness reached; With
water filter: Annual descaling
due
Service Error Display Text (E) Error Description Reason Solution
Errorcode Category
9123 2 Switch coffee machine off and Error during moving into brewing Error during moving into brewing Switch machine off/on, check
on again. In case of error, position! position! (possibly power not brewer resp. brewer motor
please call service! sufficient)
9178 1c [graphic] Grounds container has been Grounds container has been Confirmation with Yes erases
Grounds container empty? emptied. The operator is asked emptied the filling level counter;
whether the grounds container interruption with No does not
has been emptied. erase the filling level counter
9194 1a Milk empty soon, please refill Milk empty sensor reports too Milklevel below milk sensor. Refill milk or cancel display
milk. little milk available, defined Beverage lockout is activated, message!
remaining quantity not yet remaining number of beverages
reached, milk beverages not will be dispensed until beverage
blocked. lockout.
9213 1d Please wait, machine heats up, Boiler or steam boiler Large quantities of hot water or Wait
beverage dispensing is blocked! temperature too low. steam have been dispensed,
Service Error Display Text (E) Error Description Reason Solution
Errorcode Category
9216 2 Switch coffee machine off and Brewing time limit exceeded Beverage could not be Grinding degree possibly too
on again. In case of error, dispensed within the max. time. fine or taming pressure too
please call service! strong.
9255 1c Insert brewing unit! Little power input of brewer Brewer has been removed Insert brewer
Please consult user manual! motor
9298 3b [graphic] Care kit due see service concept Carry out care
Service care due. Please fit care
kit
9299 3b [graphic] Service due service see service concept Carry out service maintenance 1
Service maintenance1 due. maintenance 1
Please call service!
9300 3b [graphic] Service due service revision see service concept Carry out revision
Service revision due. Please call
service!
9301 3b [graphic] Carry out descaling see service concept Carry out descaling
Descaling due. Please carry out
descaling
9302 3b [graphic] Service due water filter see service concept Exchange water filter
Water filter exhausted. Please
exchange water filter
Service Error Display Text (E) Error Description Reason Solution
Errorcode Category
9303 3b [graphic] see service concept Time or number of brewings Change grinder disks grinder 2
Service grinder 2 due. Please reached
call service!
9304 3b [graphic] Service grinder 1 due see service concept Change grinder disks grinder 1
Service grinder 1 due. Please
call service!
9306 3b [graphic] Service due powder hopper 1 see service concept Exchange powder portioner 1
Service powder hopper 1 due. motor
Please call service!
9307 3b [graphic] Service due. Mixer 1 mixer see service concept Exchange mixer 1
Service mixer 1 mixer motor motor
due. Please call service!
9335 2 Switch coffee machine off and Overtemperature steam wand Overtemperature (> 200°C) or Sensor defective resp. exchange
on again. In case of error, sensor temperature sensor short circuit sensor
please call service!
9336 2 Switch coffee machine off and Temperatur break steam wand Sensor removed or cable break Plug on sensor/exchange
on again. In case of error, sensor (< -4°C)
please call service!
9344 1b Please refill milk Milklevel below Milksensor (1) Milklevel Milk 1 below Refill milk
Milksensor. Beverage lockout is
not selected
Service Error Display Text (E) Error Description Reason Solution
Errorcode Category
9346 1b Please refill milk. No dispensing Beverage lockout reached. No Number of remaining beverages Refill milk
of beverages with milk! dispensing of beverages with dispensed. Beverage lockout
milk! reached.
9357 1c Check water supply External water tank is empty Fill water tank...
9358 2 Milk in cooler too warm! No Determine level as of which Warm milk is refilled Wait or exchange milk
dispensing of beverages with temperature milk dispensing is
milk! blocked
Temperature range: 4°C - 24°C
9364 1c [graphic] Drip tray full. Drip tray sensor reports full Empty drip tray, dry sensor area
Please empty drip tray
9370 1d Eco Mode activet Machine has switched to Eco -> Eco mode has been activated -> Wait until machine has
mode in service menu and machine heated up
was not used for 10 min. -> Deactivate Eco mode in
system menu.
9398 1c Door of mixer open, please Door of mixer right open, -> Door open -> Close door
close! machine not ready to operate -> Magnet switch defective -> Check/exchange magnet
switch
-> Magnet in door missing -> Check magnet/exchange door
-> Magnet switch not plugged in -> Plug in magnet switch
Service Error Display Text (E) Error Description Reason Solution
Errorcode Category
9400 2 Switch coffee machine off and Configuration faulty Configuration file faulty Upload backup from USB stick
on again. In case of error, to machine or prgram again and
please call service! restart machine
9406 2 Switch coffee machine off and IO, Timeout Error during communication with Check communication (CAN,
on again. In case of error, Timeout at On/Off on time or the underlying hardware. serial, network), retry
please call service! one entry has not reported within Software error
a required time.
9429 2 Please check whether brewing Motor, timeout during start of Brewer blocked or dirty. Brewer, Motor, encoder, check
unit is inserted correctly? movement Communication with power driving parameters and driving
Motor does not even start stage lost. Motor blocked. routes.
moving or does not reach its Encoder defective. Drive
destination. parameter (e.g. drive current)
faulty.
9456 2 Switch coffee machine off and Overcurrent brewer or grinders -> Overcurrent brewer -> Check, exchange brewer
on again. In case of error, control recognized. Machine not -> Overcurrent grinders -> Check, exchange grinders 1
please call service! ready. or 2
In order to protect the power
stage all outputs are switched off
9457 2 Switch coffee machine off and Overcurrent grinder control Overcurrent grinder control Check and exchange grinder
on again. In case of error, recognized. Machine not ready recognized. In order to protect components
please call service! the power stage all outputs are
switched off
Service Error Display Text (E) Error Description Reason Solution
Errorcode Category
9458 2 Switch coffee machine off and Overcurrent output control Overcurrent output control Check and exchange valves
on again. In case of error, recognized recognized. In order to protect
please call service! the power stage all outputs are
switched off
9459 2 Switch coffee machine off and Overcurrent motor control Overcurrent motor control Check and exchange motors
on again. In case of error, recognized recognized. In order to protect
please call service! the power stage all outputs are
switched off
9463 2d Switch coffee machine off and Guarding error, node does not Hardware, Timing, .. Service
on again. In case of error, respond within the
please call service! predetermined time period
9467 1b [graphic] Portioner 1 empty Brewer detects too little ground Refill portioner 1 and confirm
Brewer detects too little ground coffee in the brewing chamber. message. The already portioned
coffee in the brewing chamber. ground coffee is disposed of and
the total quantity is portioned
again (plus additional time in
order to fill the grinder spout).
9468 1b [graphic] Portioner 2 empty Brewer detects too little ground Refill portioner 2 and confirm
Brewer detects too little ground coffee in the brewing chamber. message. The already portioned
coffee in the brewing chamber. ground coffee is disposed of and
the total quantity is portioned
again (plus additional time in
order to fill the grinder spout).
Service Error Display Text (E) Error Description Reason Solution
Errorcode Category
9475 1c [graphic] Drip tray missing Drip tray removed Reinsert drip tray
Please reinsert drip tray. Pay
attention that the bottom side of
the trip tray and the market
sensor area is dry.
9477 2 Switch coffee machine off and PowerFail detected Under- resp. overcurrent; Under- resp. overcurrent; check
on again. In case of error, interruption of power supply power supply / plug-in
please call service! connection
9479 2 Switch coffee machine off and Voltage does not swich on Electrical error in machine. Analyse and eliminate error
on again. In case of error, Short circuit at 24/30V
please call service!
9480 2 Minimum flow brewing. Minimum flow is underrun during Wrong settings Confirm error message, reset
Repetition: Please confirm testing settings and test again
9484 2 Timeout during filling of boiler. During 1st heating up timeout -> Water tank empty -> Fill water tank
Please refill water tank. has been detected at steam -> Pump defective -> Check pump
Attention, if confirmed, system is boiler supply. -> Infeed valve steam boiler -> Check infeed valve steam
automatically ventilated and hot defective boiler
water is dispensed.
Service Error Display Text (E) Error Description Reason Solution
Errorcode Category
9487 2 Switch coffee machine off and Brewer not standardised, Error in Init of machine or check sensor / motor
on again. In case of error, position invalid. switched to component test
please call service! ahead of time. Besides, the
brewer is also not standardised
anymore after sensor errors (F8)
9488 1c Manual insert open too long. Manual insert brewing has been Manual insert open or manual Close manual insert or check
Please close manual insert. started, but manual insert lid has insert switch defective. manual insert switch.
Beverage is not dispensed. not been closed again within the
time limit.
9489 2 Manual insert open. Please During beverage dispensing -> Maloperation -> Avoid maloperation
close manual insert. (with brewing) manual insert is -> Support clip of manual insert -> Exchange support clip of
opened. defective manual insert
-> Magnet switch defective -> Check / exchange magnet
switch
9490 2 Switch coffee machine off and Max. number of brewer motor Brewer too stiff or quality level Check brewer, clean it or adjust
on again. In case of error, current errors is reached! too high. Error multiply quality level.
please call service! recognized
9492 3b [graphic] Service due service see service concept Carry out 2-year maintenance
Service maintenance 2 due. maintenance 2
Please call service!
Service Error Display Text (E) Error Description Reason Solution
Errorcode Category
9496 3b [graphic] Service due brewer motor see service concept Change brewer motor
Service brewer motor due.
Please call service!
9499 3b [graphic] Service grinder 2 motor due see service concept Change motor grinder 2
Service grinder 2 motor due.
Please call service!
9500 3b [graphic] Service grinder 1 motor due see service concept Change motor grinder 1
Service grinder 1 motor due.
Please call service!
9506 1c Milk system cleaning has to be Milk cleaning must be completed Milk cleaning has been carried Confirm message so that the
completed in order to release in order to use the milk system out during machine cleaning. In Easy Milk cleaning can be
dispensing of beverages with again. order to use milk beverages continued and completed
milk. after restart, milk must be
Continue cleaning process? activated.
9508 1b Switch coffee machine off and Temperature sensor cooler is No cooler (wrong configuration), Check configuration / cable
on again. In case of error, not recognized, cable break, ...
please call service! A temperature value of -128°C
means that sensor is not
available.
9509 1b Switch coffee machine off and Temperature sensor cooler Temperature sensor reports Check / exchange temperature
on again. In case of error, reports -12°C. undertemperature milk sensor
please call service! Temperature sensor defective.
Service Error Display Text (E) Error Description Reason Solution
Errorcode Category
9510 1b Milk too warm. Switch on cooler, Milk too warm Temperature sensor reports Switch on cooler and check
test. overtemperature milk function
9511 1c Please continue and complete Continue descaling During descaling machine has Continue descaling.
descaling been switched off.
9512 2 Switch coffee machine off and sensor break temperature sensor break temperature Change temperature sensor
on again. In case of error, sensor brewing water sensor brewing water brewing water
please call service!
9514 1d Attention! Grounds container has been Additional query required. If the
Hot water can flow from hot pulled out cleaning! hot water dispensing is
water spout! interrupted by an action
(grounds container, front panel,
water pressure switch.,,,), a
query is required prior to
proceeding in order to continue
the once confirmed hot water
dispensing.
9516 2 [graphic] Portioner 1 blocked Grinder blocked Check /clean grinder or adjust
Grinder blocked. grinding degree.
For description, please consult
user manual!
9517 2 [graphic] Portioner 2 blocked Grinder blocked Check /clean grinder or adjust
Grinder blocked. grinding degree.
For description, please consult
user manual!
Service Error Display Text (E) Error Description Reason Solution
Errorcode Category
9529 1d Manual insert processing Tablet insert has been opened Operating error Confirm, afterwards brewer goes
Timeout: Brewing chamber without request and closed into basic position
contents is discharged again. Manual insert has been
opened too long, time excess
manual insert processing.
9530 1b Please proceed milk system Forced Milk system cleaning Milk system cleaning neccessary proceed Milk system cleaning
cleaning
9532 2 Switch coffee machine off and Error during moving into Motor could not reach target Switch machine off and on
on again. In case of error, position!!! (possibly power too position again; check brewing unit for
please call service! low) stiffness
9534 1d Please wait. Brewer drives automatically for Brewer drives automatically for wait
standardizing as it has possibly standardizing as it has possibly
been removed been removed
9572 1c [graphic] Drip tray full. Drip tray sensor reports full Empty drip tray, dry sensor area
Please empty drip tray between cleaning cycle
9574 2d The machine has not been The machine has not been The machine has not been Inform customer to push the off-
switched off correctly. On-/Off- switched off correctly. switched off correctly. switch only shortly.
switch pushed longer than 5s. (PowerFail) Button pushed (PowerFail) Button pushed
longer than 5s, plug pulled out. longer than 5s, plug pulled out.
9583 2 Boiler heating has been After pressure reduction routine Pressure reduction routine has
deactivated for service heating remains off until it is been carried out.
purposes. Switch heating on activated again by the service.
again?
9584 2 Minimum flow descaling. Minimum flow underrun during Too little FM pulses have been After confirmation, descaling is
Repetition: Please confirm descaling recognized. continued
9587 2 Switch coffee machine off and Drip tray sensor reports error, -> Sensor drip tray defective -> Exchange drip tray sensor
on again. In case of error, therefore machine is not ready -> Sensor drip tray cable not -> Plug in cable of drip tray
please call service! to operate plugged in sensor
-> Power stage defective -> Exchange power stage
-> Sensor cable defective -> Exchange cable
Service Error Display Text (E) Error Description Reason Solution
Errorcode Category
9588 2 Switch coffee machine off and Tank sensor reports error, -> Tank sensor defective -> Exchange tank sensor
on again. In case of error, therefore machine is not ready -> Tank sensor cable not -> Plug in cable of tank sensor
please call service! to operate plugged in -> Exchange power stage
-> Power stage defective -> Exchange cable
-> Sensor cable defective
9589 2 Timeout during filling of water Level sensor detects no water ->Level sensor defective -> Exchange level sensor
tank! Check water supply. despite filled water tank and -> Constant water modulde not -> Plug constant water module
Switch coffee machine off and reports water tank empty connected to machine plug in machine
on again. -> Inlet valve in constant water -> Exchange constant water
module defective module
-> Water supply not in order -> Check water supply
(Hose defective?) -> Exchange water tank
-> Water tank defective
9590 2 Insert water tank! Sensor did not recognize water Water tank not inserted Insert water tank
tank Water tank sensor defective Exchange water tank sensor
Cable water tank sensor not Plug cable into water tank
plugged in
9591 2 Switch coffee machine off and Drip tray sensor reports error, -> Sensor drip tray defective -> Exchange drip tray sensor
on again. In case of error, therefore machine is not ready -> Sensor drip tray cable not -> Plug in cable of drip tray
please call service! to operate plugged in sensor
-> Power stage defective -> Exchange power stage
-> Sensor cable defective -> Exchange cable
Service Error Display Text (E) Error Description Reason Solution
Errorcode Category
9592 2 Switch coffee machine off and Tank sensor reports error, -> Tank sensor defective -> Exchange tank sensor
on again. In case of error, therefore machine is not ready -> Tank sensor cable not -> Plug in cable of tank sensor
please call service! to operate plugged in -> Exchange power stage
-> Power stage defective -> Exchange cable
-> Sensor cable defective
9593 1c Empty drip tray reinserted? If during beverage dispensing Drip tray full - message during Empty and reinsert drip tray.
Beverage dispensing is "drip tray full" is reported, beverage dispensing Afterwards, start beverage
continued. beverage dispensing is dispensing again by pressing the
cancelled and drip tray must be arrow.
emptied. After having reinserted
the empty drip tray, this query
appears before beverage
dispensing in order to avoid that
the previously started beverage
starts running by itself.
9594 1c Water tank empty, water tank is Constant water machine - it was -> Water tank empty -> Fill water tank
filled! detected that an empty water -> Level sensor defective -> Check / exchange level senor
tank has been inserted. -> Cable break level sensor -> Check cable level sensor
-> CPU defective -> Check / exchange CPU
9596 2 Switch coffee machine off and The power supply has been -> An overcurrent (short -> Switch off machine for at least
on again after 60 seconds. In switched off temporarily circuit) was detected which has 60 seconds and afterwards
case of error, please call switched the power supply off. switch on again
service! -> Short circuit on Motors,
valves, pumps.... -> Check Motors, valves,
pumps...
Service Error Display Text (E) Error Description Reason Solution
Errorcode Category
9604 1c Continue dispensing? Beverage dispensing interrupted -> water tank empty -> fill water tank
by an internal process (water -> drip tray full -> empty drip tray
tank empty....) and can now be
continued
9609 2 Overtemperature control The temperature of the triacs on -> Temperature heating triac too -> Let system cool down, if
elecronics, please wait... the power stage is too high. high required exchange CPU
or Power stage has been
Switch coffee machine off and deactivated to cool down. As
on again. In case of error, soon as regular temperature is
please call service! reached, the machine will be
ready to operate again.
9610 1d Machine calibration is carried After inital operation has been -> Initial operation has been -> Wait until machine is filled
out.... carried out, the machine is filled carried out successfully -> Pump defective, level probe
with water and heats up, -> Machine is not filled not touched
afterwards it is ready to operate. -> Machine does not heat up -> Heating not plugged, Klixxon
triggered
9630 1d Heating-up phase after Eco Machine cooled down to Eco Eco Mode active Wait until machine is heated up
mode. Please wait. Mode. Requires short heating-up
phase in order to reach
operating temperature
9631 1d Dispensing is continued Descaling has been interrupted -> Water tank empty -> Fill water tank
by an internal process (water -> Drip tray full -> Empty drip tray
tank empty....) and can now be
continued
Service Error Display Text (E) Error Description Reason Solution
Errorcode Category
9852 2 SD card not available or cannot SD card not detected or cannot SD card not assembled or Plug in SD card or change
be written on be written on cannot be written on anymore defective one
9879 2 Switch coffee machine off and No recipe found for the pushed The button allocation has been Wait a moment and retry or carry
on again. In case of error, buttons. changed but not updated in the out a restart of the machine.
please call service! software.
9880 2 Check and set time Current time settings invalid Set time.
Switch coffee machine off and
on again. In case of error,
please call service!
9881 1c Please select beverage Waiting for beverage start, Beverage to be prepared Press beverage button within
brewing chamber has been filled through manual insert limit time, afterwards a coffee
with ground coffee through the beverage is started
manual insert
9883 2 Please carry out power stage Power stage: Firmware version The read firm ware version does Update power stage
update. Version is not is not compatible not correspond to the expected
compatible. one.
F120 2 Switch coffee machine off and Power stage not connected to Power stage not connected to Check cable / coding
on again. In case of error, front panel front panel
please call service!
Service Error Display Text (E) Error Description Reason Solution
Errorcode Category
F121 2 Switch coffee machine off and Dialogue error CAN, no Node not available, load Check load resistance
on again. In case of error, communication with at least one resistance, cable break
please call service! node (power stage/stepper)
F130 2 Switch coffee machine off and General current error, Short circuit 24V/30V 24V/30V check / exchange
on again. In case of error, Total power input of machine components
please call service! exceeds the upper limit
F161 (9269) 2 Minimum flow brewing. Please Water pressure check has been - Coffee adjustments wrong - Check or modify coffee
dismantle brewing unit and clean carried out. Pulses have been - Components dirty or broken adjustments
sieve! For description, please detected through release valve. - Check, clean or change faulty
consult user manual! Not through brewing unit components
F161 (9329) 2 Minimum flow brewing. Minimum flow underrun during Too little FM pulses have been After confirmation, brewing is
Repetition: Please confirm brewing recognized. continued with reduced pump
pulse
F162 (9270) 2 Minimum flow cleaning. Please 2nd level: Minimum flow during Water pressure check has been Check brewing path (e.g.
dismantle brewing unit and clean cleaning. Confirmation not carried out. Pulses have been dismantle brewing unit, clean
sieve! For description, please possible. Machine has to be detected through release valve. sieve)
consult user manual! restarted. Not through brewing unit
F162 (9330) 2 Minimum flow cleaning. Minimum flow underrun during Too little FM pulses have been After confirmation, cleaning is
Repetition: Please confirm cleaning recognized. continued
Service Error Display Text (E) Error Description Reason Solution
Errorcode Category
F167 2 Minimum flow at descaling. Minimum flow at descaling Water supply blocked (e.g. sieve Check water supply. Remove
pressure reducer/sieve water blockage or defective
tank clogged; oscillation pump component or exchange it
does not work)
F185 2 Switch coffee machine off and Max. time steam dispensed Max. time steam dispensed Check level probe and steam
on again. In case of error, without refill of steam boiler and without refill of steam boiler and boiler feed valve
please call service! without PW level change without PW level change
F186 2 Timeout during filling of boiler. Timeout steam boiler supply -> Water tank empty -> Fill water tank
Please refill water tank. during heating up -> Pump defective -> Check pump
Attention, if confirmed, system is -> Infeed valve steam boiler -> Check infeed valve steam
automatically ventilated and hot defective boiler
water is dispensed.
F187 2 Switch coffee machine off and Sensor break steam boiler Sensor is not recognized. Digit Check temperature sensor /
on again. In case of error, evaluation (digit value 1024) cable
please call service!
F188 2 Heating! Disconnect machine Overtemperature steam boiler Target temperature exceeded Check sensor system / SSR
from power supply and call
service!
F189 2 Switch coffee machine off and Steam boiler has not reached -> Klixxons (temperature limiter) Klixxon triggered - exchange
on again. In case of error, temperature in predefined time triggered steam boiler
please call service! -> Heating defective
-> Cable not plugged in
-> CPU defective
Service Error Display Text (E) Error Description Reason Solution
Errorcode Category
F2 2 Switch coffee machine off and Current error brewer Power sensor does not report Check / exchange brewer motor
on again. In case of error, power, encoder does not report
please call service! pulses.
F3 2 Switch coffee machine off and Encoder brewer motor Encoder does not deliver pulses; Check / change encoder.
on again. In case of error, power sensor reports traction
please call service! current.
F6 2 Switch coffee machine off and Blocking error brewer Blocking current detected; Check / clean brewing unit
on again. In case of error, brewing unit stiff
please consult user manual!
F7 2 Insert brewing unit! Little power input of brewer Brewer has been removed Insert brewer
Please consult user manual! motor
F87 2 Switch coffee machine off and Sensor break boiler Temperature sensor is not Check resp. exchange
on again. In case of error, recognized temperature sensor
please call service!
F88 2 Overtemperature boiler. Overtemperature boiler Target temperature exceeded Check sensor system / SSR
Attention: Disconnect machine
from power supply!
F89 2 Switch coffee machine off and Heating time boiler Boiler has not reached
on again. In case of error, temperature in predetermined
please call service! time