Air Adjustment Values

This document provides information about air adjustment values for the external air, tangential air, dispersion air, and cooling air on the FCL Lukavac Kiln Line 2. The external air makes the flame narrow and more stable and sucks in hot secondary air. The tangential air makes the flame shorter or longer and can impact NOx values. The dispersion air makes the flame shorter and wider and brings in oxygen to the center. The cooling air shortens the flame and cools the central body of the burner.

Uploaded by

DIAGNE
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
110 views1 page

Air Adjustment Values

This document provides information about air adjustment values for the external air, tangential air, dispersion air, and cooling air on the FCL Lukavac Kiln Line 2. The external air makes the flame narrow and more stable and sucks in hot secondary air. The tangential air makes the flame shorter or longer and can impact NOx values. The dispersion air makes the flame shorter and wider and brings in oxygen to the center. The cooling air shortens the flame and cools the central body of the burner.

Uploaded by

DIAGNE
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 1

FCL Lukavac Kiln Line 2

Air adjustment values

Range Use
External Air: 180 – 400 mbar Makes the flame narrow and more stable, also sucks the
hot secondary air into the flame.
Tangential Air: 20 – 80 mbar Makes the flame shorter or longer, it may also changes
the NOx values.
Dispersion Air: 40 – 60 mbar Makes the flame shorter and wide, brings O2 in the
center of the burner.
Cooling Air: 80 – 180 mbar Shorten the flame and cools the central body of the
burner itself.

Headquater:
Banking Connection: Kasernstr. 16-18
Oberbank AG . Bank Code: 15022 3500 Krems . Austria
Account no.: 511 07 77 60 . S.W.I.F.T. Code: OBKLAT2L Tel: +43 (0) 2732 75 680
Iban no.: AT331502200511077760 . Company Reg. no. FN355876y Fax:+43 (0) 2732 75 680 201
Commercial Court: Krems . VAT-ID: ATU66178012 . www.atec-greco.com E-Mail: [email protected]

You might also like